ML063050603
| ML063050603 | |
| Person / Time | |
|---|---|
| Site: | Pilgrim (DPR-035) |
| Issue date: | 06/29/2006 |
| From: | Jennifer Davis Office of Nuclear Reactor Regulation |
| To: | Ford B, Mogolesko F Entergy Corp |
| References | |
| %dam200612, TAC MD2296 | |
| Download: ML063050603 (5) | |
Text
LetHoad-Additional QuestionFrom Bob Jackson Page From:
James Davis To:
Bford@entergy.com; Dellisl @entergy.com; Fred Mogolesko Date:
6/29/2006 10:08:52 AM
Subject:
Additional Question From Bob Jackson Bob Jackson has an additional question that should be easy to answer.
Jim CC:
jacksonwr@ @msn.com; Kenneth Chang; Ram Subbaratnam
I[p.\\t,ýMpj\\q)NJ00001.TMP c:tm\\WOO0 TPPage
,!,1 Mail Envelope Properties (44A3DEF1.D48: 22: 35346)
Subject:
Creation Date From:
Created By:
Additional Question From Bob Jackson 6/29/2006 10:08:49 AM James Davis JAD@nrc.gov Recipients entergy.com BFord (Bford@entergy.com) dellisl (Dellisl @entergy.com) fmogole (Fred Mogolesko) msn.com jacksonwr CC (Jacksonwr@ @msn.com) nrc.gov OWGWPOO3.HQGWDOO1 KXC2 CC (Kenneth Chang) nrc.gov TWGWPO02.HQGWDO01 RXS2 CC (Ram Subbaratnam)
Post Office Route entergy.com msn.com nrc.gov nrc.gov OWGWPOO3.HQGWDO01 TWGWPO02.HQGWDOO1 Files Size MESSAGE 383 AMR Question Set #04 -- Jackson.wpd AM Date & Time 6/29/2006 10:08:49, 7034 6/29/2006 10:03:14 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
None Standard No None No Standard
jI c\\temp\\GWI00001.TMP Page 21 Junk Mail Handling Evaluation Results Message is not eligible for Junk Mail handling Message is from an internal sender Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled
Questions Related to PNPS Aging Management Review Results for LRA Section 3.1.1 (Reactor Vessel, Internals and Reactor Coolant System)
Prepared by Bob Jackson Question Number:
Q ue'stion NEW QUESTION: (Submitted after site audit) 6/29/2006 3.1.1-34:
LRA Table 3.1.2-1 includes three AMR results lines related to bolting. Two of these lines
("incore housing bolting" and "other pressure boundary bolting") identify the aging effect of cracking (not due to fatigue) and the aging management program is Inservice Inspection.
GALL AMP XI.M18 (Bolting Integrity) refers to ASME Section XI requirements for detection of aging effects. However, for high strength bolting (> 150 ksi), the GALL AMP states that for bolting size greater than 1-inch nominal diameter a volumetric examination comparable to that of ASME Section XI Examination Category B-GUI is required in addition to the visual examination required by Examination Category B-G-2 (for pressure retaining bolting 2" and less in diameter).
Sufficient information has not been found in the LRA or in other documents reviewed to determine whether the incore housing bolting and other pressure boundary bolting in Table 3.1.2-1 can be excluded from the augmented examination.
Question:
For the components described as "incore housing bolting" and "other pressure boundary bolting" in LRA Table 3.1.2-1, please provide the following information.
- 1) Is the yield strength of these components greater or less than 150 ksi?
- 2) Is the diameter of these components greater than 1", and less than or equal to 2"?
- 3) If any of these components have yield strength greater than 150 ksi and diameter between 1" and 2", will PNPS perform the augmented volumetric inspection as recommended in the GALL report? Alternatively, if such components are used at PNPS and PNPS does not propose to perform the augmented volumetric inspection, please provide a plant-specific basis to waive the augmented requirement of the GALL AMP.
Page 1 of 2
Questions Related to PNPS Aging Management Review Results for LRA Section 3.1.1 (Reactor Vessel, Internals and Reactor Coolant System)
Prepared by Bob Jackson Question Number:
Question Page 2 of 2