Drawing M896, Rev 34, Flow Diagram Post Accident Sampling System.
ML053270160
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 02/08/2002
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M896, Rev 34
Download: ML053270160 (1)


Text

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PRIMARY CONTAINMENT REACTOR BUILDING NOTES:

RMS

1. ALL ITEMS MARKED OR LOCATED IN THE RADWASTE BLDG.

EL. 581'-0" 4 SP CP-3/1 ARE FURNISHED WITH ASSOCIATED EQUIPMENT.

RMS 98 3/4"PSR(98)-4S REACTOR BLDG. RADWASTE BLDG.

2

2. FOR FLOW DIAGRAM LEGEND, SYMBOLS, AND ABBREVIATIONS OC OC SEE NOTE CP-3/2 OC OC SEE DRAWING M501.

K PSR-FU-1 6 & 16 1"PI(1)-4S-X80b SEE NOTE HEAT TRACE EQUIPMENT BOUNDARY PSR-SR-46 K NOTE 17 3. ALL INSTRUMENTATION ON THIS DRAWING TO BE INDENTIFIED 6 & 16 T T (SEE NOTE 12)

BY PREFIX "PSR" UNLESS SPECIFICALLY NOTED OTHERWISE.

LO 1/2"PSR(98)-1S DRYWELL ATMOSPHERE EXAMPLE: FI IS IDENTIFIED AS PSR-FI-2.

RMS PSR-V-102 PSR-V-X80/1 2 PSR-V-X80/2 HEAT TRACE TO BHD 11 SEE NOTE 14 HC/704 X-80b 1/2"PSR(98)-1S CP-2 4. ALL PRESSURE AND FLOW INSTRUMENT ROOT VALVES SHALL PSR-V-020/2 NOTE 5c NOTE 5b HEAT TRACE TO BE 3/4" GLOBE VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.

RW PENETRATION 584'-6" SP 3/4"PSR(99)-4S (SEE NOTE 12) OC OC TM 5. PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DRAWING OC OC SEE NOTE 99 6 & 16 712 SHALL BE CLASSIFIED AS FOLLOWS (BREAK POINT INDICATED ON PSR-FU-2 1"PI(1)4S-X73f SEE NOTE CP-2 FLOW DIAGRAM):

SEAL PLATFORM NOTE 17 EL. 582'-8 1/4" T 6 & 16 T a) PIPING AND VALVES FORMING PART OF REACTOR COOLANT LO RMS PRESSURE BOUNDARY (RCPB).

SEISMIC CATEGORY: I PSR-V-103 PSR-V-X73/1 HC/705 CP-2 QUALITY CLASS: I PSR-V-X73/2 PSR-SV-719 SEE NOTE 14 CP-2 CODE GROUP: A X-73f SEE NOTE 6 & 16 PI NOTE 5c 1/2"PSR(99)-1S 708 b) PIPING AND VALVES FORMING PART OF CONTAINMENT NOTE 5b SEE PRESSURE BOUNDARY.

PSR-V-021/1 OC OC J NOTE 12 OC OC PSR-V-X83/1 1/2"PSR(100)-1S CP-2 SEISMIC CATEGORY: I J

1"PI(1)-4S-X83a HEAT TRACE TO SEE NOTE HEAT TRACE PSR-SV-721 RMS QUALITY CLASS: I RW PENETRATION PT X-83a 6 & 16 T (SEE NOTE 12) CODE GROUP: B T HEAT TRACE TO BHD 10 HC/720 1/2"PSR(100)-1S SUPPRESSION POOL ATMOS 708 c) PIPING AND VALVES BEYOND OUTERMOST ISOLATION VALVE SP AND INSTRUMENT LINES, UNLESS OTHERWISE NOTED.

100 L.O. 1" 1" PSR-V-X83/2 SEISMIC CATEGORY: II 1"PSR(100)-4S PSR-V-145 2 PSI N2 FROM QUALITY CLASS: II PSR-CP-2 OC OC CODE GROUP: D OC OC PSR-V-022/1 PIPING SUPPORTS IN SEISMIC AREAS ARE DESIGNED TO PSR-V-146 CP-2 SEE NOTE 6 & 16 O PSR-SV-720 SEISMIC CATEGORY I LOADS.

X-84f PSR-V-147 SEE NOTE 6 & 16 RMS C IN ADDITION, PIPING, VALVES, AND INSTRUMENTS INSIDE PSR-SV-718 PSR-FU-3 T T PSR-SV-723 L.O. SAMPLING RACKS PSR-SR-46, PSR-SR-47, AND PSR-CP-1 HC/723 POS SP AND PSR-CP-2.

101 PSR-V-148 PSR-V-X84/1 PSR-V-X84/2 SA ZS/720 SEISMIC CATEGORY: II 1"

1"PSR(101)-4S 1" PSR-V-150 705 HEAT TRACE TO 1/2"PSR(101)-1 15 ML GAS SAMPLE

6. THE VALVE POSITIONS WILL BE INCLUDED IN THE ISOLATION PSR-V-149 RW PENETRATION VALVE POSITION DISPLAY PANEL.

PSR-V-023/1 (SEE NOTE 12) NOTE 5b NOTE 5c O FI 1"PI(1)-4S-X84f C 7. CONTAINMENT SAMPLING ROOT VALVE SHALL BE TAGGED AS PSR-FU-5 CP-2 H MO 725 FOLLOWS:

H NOTES 5c & 17 NOTE 5b 710 RMS POS CP-2 PSR-SV-713 HC/712 PSR-V-X(PENETRATION NO.)

SECONDARY CTMT ATMOS SAMPLE ZS/704 (NOTE 23) 3/8"PSR(102)-4S V 8. ALL PIPING SYSTEMS INDENTIFIED BY THE PREFIX "PSR" SHALL SP EL. 491'-0" SEE NOTE 11 710 PI PI R

BE SUPPLIED AND INSTALLED BY CONTRACT #220 UNLESS OTHERWISE SPECIFIED.

220 218 102 726 727 GAS COOLER LS PSR-HX-E703 SPARE PSR-SV-712 717 C. C. 9. (DELETED)

PSR-SV-711 10.

  • INDICATES VENDOR SUPPLIED.

RE RI 704 704 TI TE 11. MULTI POSITION SELECTOR VALVE.

CP-1 PSR-HX-704 724 724 PSR-T-717 REFRIG CP-2 12. THESE LINES TO BE HEAT TRACED (EXCEPT THE SOLENOIDS AT UNIT PSR-P-701 VALVES PSR-V-X73/2,X80/2,X83/1,X83/2,X84/1,&X84/2)

IODINE CARTRIDGE 3/8"PSR(1)-4S SECONDARY CTMT ATMOS SAMPLE RETURN FROM CONTAINMENT PENETRATION TO BULKHEAD CONNECTION AT PSR-F-704 PSR-SR-46.

EL. 491'-0" PSR-SV-701 G RMS TO PSR-V-X82/2 13. TEE AS CLOSE TO PENETRATION AS PRACTICAL. G 3 (B/11) 1"PI(1)-4S-X82f CP-3/1 DPI

14. LOCATE THESE VALVES SO THEY ARE ACCESSIBLE FROM PLATFORM. AT 531' EL.

OC OC OC OC 728 X-82f SEE NOTE 6 & 16 NOTE 5c NOTE 5b

  • 15. 3/4"x12" REMOVABLE SECTION FOR PUMP MAINT.

SEE NOTE 6 & 16 PSR-RV-115 T T DRYWELL/WETWELL ATMOS SAMPLE RETURN TO VENDOR SUPPRESSION POOL PSR-P-702 16. ACCESS TO THE REMOTE-MANUAL SWITCHES FOR THESE VALVES 1"PSR(1)-4S 1/2"PSR(1)-4S SUPPLIED WILL BE CONTROLLED BY KEY LOCK.

PSR-V-142 PSR-V-X82/7 PSR-V-X82/8 1" 1/4"PSR-V-024/2 L.O. PSR-V-144 1/2" PSR-SV-702 17. FOR THOSE LINES REFERRED TO THIS NOTE, PRESSURE TESTING 1" PSR-V-178 IS NOT REQUIRED.

NOTE 5b NOTE 5c PSR-V-143 PSR-V-O24/1 EQUIPMENT BOUNDARY PSR-SR-47 PSR-SPV-628/1 PSR-V-114 RMS PLANT DEMIN

18. (DELETED) 5 LG SEE NOTE NOTE 5a NOTE 5c CP-3/1 WATER HOSE CONN.

PSR-V-179 19. HEAT TRACING FROM PSR-P-4 TO 6 & 16 1 X-77Ad M517 (J/6) CONTAINMENT PENETRATION X-88 SPARED N2 FROM PSR-CP-2 PSR-V-113 IN PLACE.

OC OC OC OC 1"PI(1)-4S-X77Ad CONTR. 215 CONTR. 220 F 3/4"PSR(103)-4S SEE NOTE 6 & 16 ND FI 20. O&M MANUAL IS # GEK-83344, CVI NO. F PSR-V-628 T T 3/8"PSR(103)-4S 1 DEMIN WATER TANK 02-01,59,1 & 2.

LO ND SEE NOTE 13 PSR-HX-E605 CP-1 1" CP-2 SP 3/8"PSR(103)-4S

  • PSR-TK-4
21. REFER TO TUBING ISOMETRICS CVI NO. 220-01,1694,17 &

103 PI RMS PSR-V-112 PSR-V-100 1" PSR-V-104 JET PUMP SAMPLE 220-01,1697,5 AND STRUCTURAL DRAWING S738 (DETAIL 7757) 220 PSR-V-X77A/3 PSR-V-X77A/4 CP-3/1 PSR-V-624 662 8

1" 1" 3/4" PSR-V-105 DW-V-300 (REF) DEMINERALIZED PSR-SV-651A PSR-SV-651B FOR RADWASTE BLDG. PENETRATION #741 DETAILS.

CP-1 FS MV/I FT 215 C.

JET PUMP WATER SEE M517 O 1/2"PSR-V-001/3 1/2"PSR-V-001/4 PSR-V-OO1/2 PSR-V-001/1 PSR-V-106 C

22. FILTER CARTRIDGES HAVE BEEN REMOVED.
  1. 20 X-77Ac (F/10) 3/4" 1 1 1 FROM SW LOOP A 1" RMS CP-1 M530-1 (H/8) OC OC CP-1 PT RMS OC OC M524-1 (C/2) SW-V-840 SW-V-839 C.

HC/628/1 RI 23. WHEN ILLUMINATED, INDICATES MOISTURE TRAP PSR-T-717 O

SEE NOTE 1"PI(1)-4S-X77Ac NOTE 5c 3/4" 662 HC/652 LIQUID LEVEL IS AT OR BEYOND THE TRIP POINT.

3/4"PSR(104)-4S 6 & 16 FROM SW LOOP C

SW-V-841 CP-2 507 T CP-2 T SEE NOTE 6 & 16 ND 1" LO ND B M524-1 SP 1" 3/4" SEPTUM FOR (C/2) SW-V-842 104 PSR-V-101 1" PSR-V-107 3/8"PSR(104)-4S O DISSOLVED GAS PSR-V-X77A/1 PSR-V-X77A/2 C 1" 3/4" GRAB SAMPLE RE TO SW LOOP A 1" 507 JET PUMP 1/2"PSR-V-002/3 1/2"PSR-V-002/4 SP PSR-V-OO2/2 PSR-V-002/1 M524-1 (C/2) SW-V-843 O

C SW-V-844 N2 FROM PSR-CP-2

  1. 10 3/4" PSR-TK-662 E M530-1 (H/9) 106 RHR LOOP A OC E

TO SW LOOP B 3/4" 1" M521-1 (A/12) 1"PSR(106)-4S M524-1 (C/2) SW-V-845 SW-V-846 SEE NOTE 6 & 16 SW PSR GAS 3/8"PSR(106)-4S COLLECTION PSR-V-003/A RHR SAMPLE PSR-V-625 SP CHAMBER 107 RHR LOOP B OC 1"PSR(107)-4S HEAT TRACE SEE NOTE 6 & 16 NOTE 19 M521-2 (C/5) 3/4"x12" SEE NOTE 15 RMS PSR-V-003/B PSR-SV-653 (TYP 6 PLACES) HC/601 C218 NOTES 5c & 17 NOTE 5b OC OC OC OC CP-2 SEE NOTE 6 & 16 PIPING RACK PSR-SR-47 PSR-CP-1 NOTE 5b NOTE 5c PSR-V-011 PSR-CP-2 DEMINERALIZED WATER X-88 1" 1"PI(1)-4S-X88 O PSR-P-4 M517 (B/9)

T T C 3/8"PSR(105)-1S 3/4"PSR(105)-4S WALL PENETRATION #741 (SEE NOTE 21)

PSR-V-154 PSR-V-726 D PSR-V-141 PSR-V-X88/1 PSR-V-X88/2 PSR-V-117 1 1/2" AO RMS D SEE DETAIL"A" AND L.O.

1" 1" PSR(105)-1S (TYP) HC/626 PSR-TK-610 SP PSR-V-012 DEMINERALIZED WATER PSR-V-620/1 TO PSR-V-624 (F/7)

PSR-SR-46 PSR-V-004/1 PSR-V-004/2 PSR-V-004/3 PSR-V-004/4 105 SUPPRESSION O PSR-P-5 M517 (B/9) BUBBLER (PSR-SR-47)

PSR-SPV-624 PSR-FU-8 POOL 3/4"PSR(108)-1S C 3/8"PSR(108)-1S TUBE FDR-SUMP-R1 PSR-V-155 VENT PSR-FU-7 M539 (B/12) PSR-V-033 CP-1 TO PSR-V-625 (E/7)

SEE DETAIL"A" PSR-SPV-625 SP SP PSR-V-013 PT PI (PSR-SR-47)

TO DRAIN DEMINERALIZED WATER 109 1 1 VIA 108 SUMP PSR-RV-"B" O M517 (B/9) RMS PSR-SPV-626 3/4"PSR(109)-1S C PSR-P-6 3/8"PSR(109)-1S HC/616/1 TO PSR-V-626 (B/7)

PSR-SR-47 FDR-SUMP-R2 PSR-V-156 C.220 CP-2 (PSR-SR-47) PI POS PSR-SPV-620/1 M539 (B/13) PSR-V-034 PSR-SV-717 627 SEE DETAIL"A" CP-2 CP-1 ZS/616/1 PSR-FU-9 SP PSR-V-014 DEMINERALIZED WATER PSR-V-038 PI CI TO PSR-V-627 (B/7)

PSR-HX-E604 110 M517 (C/8) 661 O (PSR-SR-47) PI PSR-PRV-627 PSR-P-"A" PSR-FU-10 O

PSR-P-7 3/8"PSR(105)1S 663 CP-2 C 3/4"PSR(110)-1S C 3/8"PSR(110)-1S

  • 723 PSR-FU-"C" FDR-SUMP-R3 3/8"PSR(105)4S TI TO PSR-V-157 TO PSR-SV-723 (H/4)

C (SEE NOTE 22) M539 (B/7) PSR-V-035 PT CE 660 (PSR-SR-46) C SEE DETAIL"A" 661 PSR-PRV-723 SP PSR-V-015 663 DEMINERALIZED WATER 111 "A" "B" "C" O M517 (C/10) COOLER PTD TE AO PSR-FU-11 PSR-P-8

  • FI 3/4"PSR(111)-1S C 3/8"PSR(111)-1S 660 AO PSR-V-727 PUMP NO. RELIEF VALVE NO. FILTER NO. FDR-SUMP-R4 VENDOR 664 661 CP-2 C220 PSR-V-158 CP-2 2 PSI SUPPLIED PSR-P-4 PSR-RV-116 PSR-FU-13A M539 (B/9) PSR-V-036 RMS SEE DETAIL"A" PSR-P-5 PSR-RV-117 PSR-FU-13B PSR-V-620/2 C220 SP PSR-V-016 CP-2 PSR-V-622A HC/629/1 SQRT DEMINERALIZED WATER PSR-SR-47 PSR-P-6 PSR-RV-118 PSR-FU-13C 112 PSR-SPV-616/1 PSR-P-601 664 2 POSITION O M517 (B/8) N2 FROM 4 PORT BALL PSR-P-7 PSR-RV-119 PSR-FU-12 PSR-FU-13D 3/4"PSR(112)-1S C 3/8"PSR(112)-1S PSR-CP-2 N2 FROM VALVE FOR EDR-SUMP-R5 FT PSR-CP-2 CP-2 PSR-RV-120 PSR-FU-13E PSR-V-159 ALIQUOT PSR-P-8 M537 (A/9) PSR-V-037 664 SAMPLE PSR-V-629 RMS PSR-P-9 PSR-RV-121 PSR-FU-13F FROM PSR-RMS-3 SEE DETAIL"A" PSR-SPV-629/1 OC OC PSR-SV-722 PSR-P-9
  • HC/715/1 (G/11) OC OC C. 215 C. 220 PI PI DETAIL "A" X-82d C. 220 C. 215 SUP'N PSR-SV-650 POS O 1" T POOL SYRINGE PSR-V-616 1" PSR-V-010/3 PSR-V-626 SA C T SA ZS/608/1 100 PSI 1" 3/8"PSR(1)-4S PSR-V-622B PSR-V-725 607 608 1"PSR(1)-4S B PSR-V-151 PSR-V-X82/1 PSR-V-X82/2 SAMPLE RETURN TO SUPPRESSION POOL PSR-FCV-627 1/2" SM VOLUME LG VOLUME PSR-PCV-1 PSR-V-703 B CP-1 LIQUID SAMPLE LIQUID SAMPLE LO AO SEE NOTE
  • 1" RE RI 6 & 16 PSR-V-724 PSR-V-116 665 665 PSR-V-716 PSR-V-010/1 PSR-V-010/2 PSR-V-010/4 SUPPRESSION NOTE 5c NOTE 5b 1"PI(1)-4S-X82d PSR-TK-715 PSR-TK-3B PSR-SV-714 PSR-TK-3A POOL NOTE 5b NOTE 5c PSR-SPV-716/1 PSR-SPV-622/1 FSAR FIG.

NITROGEN TANKS PSR-V-715 COLUMBIA SAMPLE BOX SUMP PSR-SPV-715/1 GENERATING NORTHWEST STATION REV DATE DESCRIPTION DWN CHK APVD SIGNATURE DATE TITLE APPROVED A 33 1-11-02 REDRAWN PER 01284-006. NT BLS SRP A

S. PAYNE 1-11-02 34 2-8-02 REV PER 01476-014 (D/13). NT HL SRP CHECKED FLOW DIAGRAM POST ACCIDENT BEN STAFFORD 10-4-01 SAMPLING SYSTEM DRAWN N. THEISEN 12-7-00 SCALE DWG NO. REV.

NTS M896 34 PDS2-E1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 SERVER84\00\G