Drawing M539, Rev 78, Flow Diagram Floor Drain System Reactor Building
ML053270141
Person / Time
Site: Columbia 
(NPF-021)
Issue date: 09/19/2005
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M539, Rev 78
Download: ML053270141 (1)


Text

2 1

3 15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 R0 (9/94)

DWN CHK APVD 4

DESCRIPTION 5

6 DATE REV 7

8 9

10 11 12 COLUMBIA GENERATING STATION TITLE DATE SIGNATURE REV.

APPROVED CHECKED SCALE DRAWN 3

1 2

DWG NO.

A FLOW DIAGRAM FLOOR DRAIN SYSTEM REACTOR BUILDING M539 78 NTS 4WARDTECH 6-17-99 K. LUCAS 2-8-02 D. R. JACOBSEN 4-29-02 SERVER84\\00\\G MCC ROOM R611 DRAIN COL. M.7/6 AREA DRAIN COL. N.8/6 AREA DRAIN COL. N/6 CAC UNIT COL. M.7/7 CAC UNIT COL. M.7/7 AREA DRAIN COL. N/7.1 AREA DRAIN COL. L/9.4 AREA DRAIN COL. N/9.4 STANDBY GAS TREATMENT UNIT 1A AREA DRAIN COL. H.3/6.8 STANDBY GAS TREATMENT UNIT 1A COL. H.3/5.2 AREA DRAIN COL. J/8.3 AREA DRAIN COL. J/6 STANDBY GAS TREATMENT UNIT 1B COL. J/5.2 AREA DRAIN COL. J/5 COL. H.3/7.1 STANDBY GAS TREATMENT UNIT 1B COL. J/7.1 REACTOR BLDG CLOSED COOLING WATER SURGE TANK EQUIPMENT DRAIN FROM AIR WASHER ROA-HV-1 PLENUM COL. N & WEST EQUIPMENT DRAIN FROM AIR WASHER ROA-HV-1 SUMP (COL. N & EAST MCC ROOM R-612 DRAIN COL. M.7/8.3 AREA DRAIN COL. L/4.3 AREA DRAIN COL. M/4.3 AREA DRAIN COL. M.7/5 AREA DRAIN COL. N/4.1 FOR H & V REA-FU-2B COL. M.7/4.1 FOR H & V REA-FU-2A COL. M.7/3.4 1.

2.

3.

4.

5.

6.

7. (DELETED) 8.

9.

10.

11.

12.

13.

1/2"PI(1)-ST - (H22-P021)-A6 14.

CODE DESIGNATION LINE NUMBER 1.

2.

3.

LEGEND NOTES:

15.

CONTRACT 215, 205 OR 216, 206A, 213A CONTRACT 206 (6426) 3"FDR-1 4"FDR-1 3"FDR-1 4"FDR-1 3"FDR-1 4"FDR-1 3"MWR(30)-1S 3"FDR-1 4"FDR-1 4"FDR-1 4"FDR-1 1 1/2" 3"

1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 3"

1 1/2" 1 1/2" 1 1/2" 3"

3" 1 1/2" 1 1/2" 1 1/2" 3"

3" 3"FDR-1 4"FDR-1 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 3"

3" 4"

3" 3"

3"FRD-1 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 3"

CASK WASHDOWN AREA COL. N/6 SERVICE BOX "Q" COL. M.7/6 REFUELING PLATF. ELECT. BOX COL. M/6.4 SERVICE PLATF. CONN. BOX COL. M/6.4 SKIMMER SURGE TK VALVE BOX COL. M/6.8 AREA DRAIN COL. M/7.1 AREA DRAIN COL. L/8.3 TRACK DRAIN COL. M/9.4 FUEL POOL VALVE BOX COL. M/8.3 AREA DRAIN COL. N/7.7 TRACK DRAIN COL. K/9.4 FUEL POOL VALVE BOX COL. K/8.3 AREA DRAIN COL. H.3/6 AREA DRAIN COL. H.3/8.3 AREA DRAIN COL. J/4.3 SERVICE BOX "P" COL. K/3.4 AREA DRAIN COL. M/6 AREA DRAIN COL. N/4.3 AREA DRAIN COL. M.7/4.1 (CABLE TRENCH)

SERVICE BOX "N" COL. K/5 (CABLE TRENCH)

SERVICE BOX "M" COL. K/5 (CABLE TRENCH)

SERVICE BOX "A" COL. M/3.4 (CABLE TRENCH)

SERVICE BOX "B" COL. M/5 (CABLE TRENCH)

SERVICE BOX "C" COL. M/5.2 (CABLE TRENCH)

SERVICE BOX "K" COL. K/7 (CABLE TRENCH)

SERVICE BOX "L" COL. K/6.8 (CABLE TRENCH)

NEW FUEL STORAGE VAULT EL. 589'-10 1/2" SERVICE BOX "J" COL. K/8.3 (CABLE TRENCH)

SERVICE BOX "H" COL. L/8.3 (CABLE TRENCH)

SERVICE BOX "F" COL. L/8.3 (CABLE TRENCH)

(CABLE TRENCH)

SERVICE BOX "D" COL. M/6.4 SERVICE BOX "E" COL. L/7 (CABLE TRENCH)

SERVICE BOX "G" COL. L/8.3 (CABLE TRENCH) 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

SAMPLING & ANALYZER ROOM 1A AREA DRAIN COL. M/4.3 AREA DRAIN COL. M.7/6.4 AREA DRAIN COL. N.8/6 AREA DRAIN COL. N.8/4.3 ANALYZER ROOM 1B AREA DRAIN, COL. M/5 NON-REGEN & REGEN HEAT EXCH. AREA DRAIN COL. L/4.1 4"FDR-1 3"

3" 3"

3" 3"

3" 3"

AREA DRAIN COL. H.3/4.3 RBCCW HEAT EXCH. 1C AREA DRAIN COL. H.3/5.2 AREA DRAIN COL. H.3/6 RBCCW PUMP-1C RBCCW PUMP-1B RBCCW PUMP-1A 3"FDR-1 4"FDR-1 4"FDR-1 3"

3" 3"

RBCCW HT. EXCH. 1C AREA DRAIN COL. J/6 AREA DRAIN COL. J/8.3 AREA DRAIN COL. K/8.3 AREA DRAIN COL. L/7.7 AREA DRAIN COL. L/8.3 3"

3" 3"

3" 3"

3"FDR-1 4"FDR-1 3"FDR-1 AREA DRAIN COL N/7.9 AREA DRAIN COL. N/8.3 RBCCW CHEMICAL ADDITION TANK COL. J/7 AREA DRAIN COL. N/3.4 C41-C001A &

C41-002 FUTURE E.D.

C41-A001 C41-C001B AREA DRAIN COL. M/7.7 3"

AREA DRAIN COL. M/8.3 3"

CRD AREA DRAIN COL. L/9.4 3"

3" 4"

AREA DRAIN COL. J/6 3"

AREA DRAIN COL. J/7.1 3"

AREA DRAIN COL. J/8.3 3"

3"FDR-1 4"FDR-1 RHR VALVE RM.

RHR VALVE RM.

COL. N/6 AREA DRAIN COL. N.8/5.2 3"

CRD AREA DRAIN COL. M.7/3.4 3"

3" 4"FDR-1 3"

3" 3"

ROOM DRAIN COL. M.7/5 RWCU RECIRC PUMP MCC ROOM R-410 DRAIN COL N/4.1 ROOM DRAIN COL. M.7/5 RWCU RECIRC PUMP RO 10A FDR 6"

PLUGGED CONN.

RO 10B FDR 6"

PLUGGED CONN.

RO 10C FDR 6"

PLUGGED CONN.

RO 10D FDR 6"

PLUGGED CONN.

3" FROM DRYER SEPARATOR POOL LINER DRAIN CONT. FROM DWG.

M526-1 (H/7)

TO ROOF DRAIN HEADER 6"RD(2)-1 (BY CONTR 216)

CONT. FROM DWG. M809 CONTR.

216 4"FDR-1 4"FDR RO 11A FDR 6"

PLUGGED CONN.

RO 12A FDR 6"

PLUGGED CONN.

6"FDR(43)-1 3"FDR-1 4"FDR-1 3"

STAND-BY LIQUID CONTROL AREA RO 11B FDR 6"

PLUGGED CONN.

RO 11C FDR 6"

PLUGGED CONN.

RO 11D FDR 6"

PLUGGED CONN.

(MISCELLANEOUS WASTE)

EL. 550'-6" EL. 548'-0" REACTOR BLDG EXHAUST STACK EL. 572'-0" EL. 606'-10 1/2" 3"FDR-1 3"FDR-1 3"

3" 3"

3" 3"MWR(50)-1S 3" FUTURE CONN.

3"MWR(59)-1S RO 12B FDR 6"

PLUGGED CONN.

RO 12C FDR 6"

PLUGGED CONN.

3"FDR EL. 535'-0" AREA DRAIN COL. M.7/5 RO 12D FDR 6"

PLUGGED CONN.

6"FDR(45)-1 PRIMARY CONTAINMENT EL. 522'-0" AREA DRAIN COL. N.8/8.3 3"

3" 3"

3" 3"

4"FDR-1 AREA DRAIN COL. M/8.3 AREA DRAIN COL. N/7.7 TRENCH DRAIN COL. M/7.7 AREA DRAIN COL. L/8.3 MWR-V-101 1"

EMERGENCY SHOWER L.C.

3"MWR(50)-1S 3"C.O.

3" DRAIN COL. K/7.7 SINK 3"

3"MWR(30)-1S CRD REPAIR ROOM 3"FDR(52)-1 COL. N/3.4 COL. K/7.7 55 GAL DRUM DECON STATION 2"MWR(30)-1S EL. 501'-0" 3"MWR(30)-1S 3"MWR(30)-1S 1"PLUGGED CONN.

3"MWR(59)-1S CONT.

6426 CONT.

DECON. PIT RO 13A FDR 6"

PLUGGED CONN.

RO 13B FDR 6"

PLUGGED CONN.

RO 13C FDR 6"

PLUGGED CONN.

RO 13D FDR 6"

PLUGGED CONN.

3"FDR-1 AREA DRAIN COL. J/4.3 CONT. 6426 CONT. 206A CONT. 6426 CONT. 206A AREA DRAIN COL. J/7.7 3"

AREA DRAIN COL. K/8.3 3"

3"FDR-1 CONT. 6426 CONT. 206A STEAM TUNNEL COL. H.3/6 COL. L/4.1 COL. K/3.4 COL. J/5 PLUGGED AREA DRAINS 3"

3" 3"

4"FDR-1 3"

3"FDR-1 EL. 510'-6" TIP MEZZANINE ROOM DRAIN COL. J/4.3 6"FDR(44)-1 COL. N/5.2 COL. N.8/6 COL. N 3"

3" 3"

4" CONT. 6426 CONT. 206A SAND FILLED CAVITY DRAIN MWR-V-120 F.C.

AO RMS MWR-SPV-120 A

MWR-V-121 F.C.

AO RMS MWR-SPV-121 A

RO 14A FDR 6"

PLUGGED CONN.

EL. 471'-0" 6"

PLUGGED CONN.

RO 15A FDR COL. N/8.3 COL. L/8.3 3"

3" 3"

AREA DRAINS CONT. 6426 CONT. 206A CONT. FROM DWG.

M537 (C/12)

RO 14B FDR 6"

PLUGGED CONN.

3"FDR-1 CONT. 6426 CONT. 206A AREA DRAIN COL. K/8.3 RO 14C FDR 6"

PLUGGED CONN.

AREA DRAIN COL. H.3/6 AREA DRAIN COL. J/4.1 3"

3" 3"

COL. M/4.1 3"

COL. N/6 COL. N/4.1 3"

3"FDR-1 3"FDR AREA DRAINS CONT. 6426 CONT. 206A RO 14D FDR 6"

PLUGGED CONN.

CONT.

206A CONT.

215 N.O.

RMS FDR-SPV-4 RMS FDR-SPV-3 T.G. BLDG.

REACTOR BLDG.

RADWASTE BLDG.

REACTOR BLDG.

FOR CONT. SEE DWG.

M538 (E/3)

CONT.

6426 CONTR.

215 CONTR.

206A CONT. 206A FDR-V-221 FDR-V-222 FDR-V-219 FDR-V-220 3"FDR(40)-1 3"FDR(41)-1 C

O C

O AO AO TO SUMP PUMPS FDR-P-3, 4A & 4B RMS RMS F,A,Z SIGNAL 3"MWR(59)-1S (CHEMICAL WASTE GRAVITY FLOW) 3" 3"

FDR-V-28 FDR-V-27 EL. 441'-0" FDR-SPV-219 FDR-SPV-220 3"RHR(24)-1 CONT. ON DWG. M521-1 (C/11)

RHR-V-120 3"FDR(77)-1 FDR-V-29 FDR-1 RHR-1 FDR-V-700(D)

AO AO O

C O

C RMS RMS FDR-SPV-222 FDR-SPV-221 TO SUMP PUMPS.

FDR-P-1A, 1B & 2 ISOLATION SIGNAL F,A,Z 4"

3"FDR(41)-1 4"FDR(40)-1 CONT. 206A CONT. 6426 6"

PLUGGED CONN.

RO 15B FDR 6"

PLUGGED CONN.

RO 15C FDR CONT. 206A CONT. 6426 EDR-1 FDR-1 FROM 3"EDR-1 M537 (C-D/10-11) 4"FDR-1 TM 604C FDR TM 605C FDR A

E31-R604C E31-R605C 6"FDR(42)-1 3"

3" 3"

SUMP PUMP FDR-P-2 G11-C003A 3"FDR(52)-1 AREA DRAIN RHR "B" PUMP ROOM AREA DRAIN RHR "B" PUMP ROOM RHR PUMP PIT ROOM 3"FDR(41)-1 2" FOR FUT. PUMP 1 1/2" FDR-V-19A FDR-V-9A PI 2

FDR FDR-V-702 REACTOR BLDG. FLOOR DRAIN SUMP FDR-SUMP-R2 LS 42 FDR A

C EL. 422'-3" LS 6A FDR LS 2A FDR AHH RMS P001 TQ 4A FDR G11-K004A G11-N002A FDR-V-602 AO (NO FLOOR DRAINS ON THIS LEVEL. GRATING ONLY) 3"EDR FROM RHR PUMP "B" RM. CONT. FROM DWG. M537 (C/13)

TM 604A FDR TM 605A FDR A

E31-R604A TQ 3A FDR 6"FDR(43)-1 G11 K003A G11-K003C G11-M001A SUMP PUMP FDR-P-1A G11-C002A SUMP PUMP FDR-P-1B G11-C002C 3"

3" REACTOR BLDG. FLOOR DRAIN SUMP FDR-SUMP-R1 LS 4A FDR LS 1A FDR T

LS 5A FDR G11-N001A G11-N005A AREA DRAIN RCIC PUMP ROOM 1 1/2" FDR-V-8B FDR-V-5B 4"FDR-1 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

3" 3"

2" PI 1B FDR FDR-V-701B LS 41 A

C FDR 1 1/2" FDR-V-8A FDR-V-5A 2"

PI 1A FDR FDR-V-701A FDR-V-607 F.C.

AO 576A FDR FDR-SPV-607 RMS T

LS 44 FDR A

C T

CONT. 6426 CONT. 206A CONT. 6426 3"EDR FROM RHR PUMP "A" RM CONT.

FROM DWG. M537 (C/13) 4"FDR(43)-1 CONT.

FROM DWG. M521-2 (A/7) 4"FDR(40)-1 FDR-V-601 AO CONT. 6426 CONT. 206A CONT. 6426 L

O L

O 3"

3" 3"

3" 3"

3" 3"

REACTOR BLDG. FLOOR DRAIN SUMP FDR-SUMP-R4 3"FDR(52)-1 3"FDR(52)-1 AREA DRAIN RHR "A" PUMP ROOM RHR PUMP PIT DRAIN SUPPRESSION POOL CLEAN-UP PUMP AREA DRAIN RHR "A" PUMP ROOM AREA DRAIN RHR "C" PUMP ROOM RHR PUMP PIT DRAIN AREA DRAIN RHR "C" PUMP ROOM 1 1/2" FDR-V-19B FDR-V-9B 3"FDR(52)-1 CONTR.

205 CONTR.

215 G11-F576A O

C 2"FOR FUT. PUMP LS 43 FDR A

T C

PI 4

FDR 2"

FDR-V-703 RMS P001 RMS P001 ALT 1A FDR TQ 3C FDR RMS P001 SUMP PUMP FDR-P-3 G11-C003B FDR TQ 4B LS 2B FDR G11-N002B G11-K004B LS 6B FDR G11-N006B AO 575 FDR RMS AHH FDR-V-609 CONTR.

215 205 CONTR.

FDR-SPV-609 F.C.

3"FDR(40)-1 TM 604D FDR TM 605D FDR E31-R604D E31-R605D A

6"FDR(44)-1 3"EDR FROM RHR PUMP "C" RM CONT. FROM DWG.

M537 (C/11) 3"FDR(40)-1 SUMP PUMP FDR-P-4B G11-C002D REACTOR BLDG. FLOOR DRAIN SUMP FDR-SUMP-R3 SUMP PUMP FDR-P-4A G11-C002B FDR-V-604 AO L

O CONT. 6426 CONT. 206A CONT. 6426 3"

3" 3"

3" 3"FDR(52)-1 3"FDR(52)-1 AREA DRAIN LPCS PUMP ROOM LPCS PUMP PIT DRAIN AREA DRAIN HPCS PUMP ROOM HPCS PUMP PIT DRAIN LS 45 FDR A

T C

3"EDR FROM LPCS PUMP ROOM CONT. FROM DWG. M537 (C/11)

CONTR. 206A LS 46 FDR A

C T

FDR-V-8D FDR-V-5D 1 1/2" PI 3B FDR FDR-V-704B FDR-V-8C FDR-V-5C 1 1/2" 2"

PI 3A FDR FDR-V-704A LS 1B FDR G11-N001B LS 5B FDR LS 4B CONT. ON M528-1 (K/5) 1"CRD(55)-1 CRD-ST-3 RMS RMS P001 RMS P001 RMS TQ 3D FDR TQ 3B FDR ALT 1B FDR 2"

3" 3"

3"FDR(52)-1 CONTR 215 FDR-V-608 F.C.

CONTR 205 AO 576B FDR FDR-SPV-608 (RHR PUMP "B" PUMP ROOM)

(RCIC PUMP ROOM)

(RHR PUMP "A" PUMP ROOM)

(RHR PUMP "C" PUMP ROOM)

(LPCS PUMP ROOM)

(HPCS PUMP ROOM)

(CONDENSATE & CRD PUMP AREA)

CONTRACT 205 CONTRACT 206 TM 605B FDR TM 604B FDR A

E31-R605B E31-R604B FD-V-30 (AZIMUTH 22 1/2)

FD-V-31 (AZIMUTH 67 1/2)

FD-V-32 (AZIMUTH 112 1/2)

FD-V-36 (AZIMUTH 157 1/2)

FD-V-37 (AZIMUTH 202 1/2°)

FD-V-33 (AZIMUTH 247 1/2)

FD-V-34 (AZIMUTH 292 1/2)

FD-V-35 (AZIMUTH 337 1/2)

NOTE 15 NOTE 15 FDR-V-603 AO L

O CONT. 6426 CONT. 206A CONT. 6426 3"EDR FROM HPCS PUMP RM. DWG.

CONT. ON M537 (C/10)

P001 RMS FDR-V-7 AO 7

FDR FDR-SPV-7 G11-F007 6"FDR(45)-1 FDR-V-1 FDR-V-742 FDR-V-613 3/4" 3/4" TEST CONN.

3/4"x 1/2"RED. (TYP. 2 PLCS.)

CALIBRATION TEST CONN.

(TYP. 2 PLCS.)

FDR-V-2 FDR-V-743 FT 038 FDR 1"

E31-N038 3/4" SQRT 38 FDR V/F 38 FDR FQ 38 FDR FRS 623 EDR T

E31-R623 6"

RO 15D PLUGGED CONN.

CONT. 206A CONT. 6426 2"FDR(51)-1 REACTOR DRY WELL BULKHEAD PLATE EL. 583'-0" DRYWELL COOLER CRA-FC-2A DRAIN PAN DRAIN PAN CRA-FC-2B DRYWELL COOLER

'REACTOR DRYWELL COOLER CRA-FC-1A DRAIN PAN DRYWELL COOLER CRA-FC-1B DRAIN PAN DRYWELL COOLER CRA-FC-1C DRAIN PAN 2"

2"FDR(46)-1 2"FDR(46)-1 2"FDR(46)-1 1"BEDPLATE DRAIN RRC-P-1A SEE DWG M530 (C/10)

ISOLATION SIGNAL A,F 2"FDR(47)-1 2"FDR(47)-1 FDR-V-614 FDR-V-647 FILL & TEST CONNECTION 3/4"FDR(55)-1-2 L.O.

FDR-V-570 FDR-V-571 3/4"FDR(55)-1-1 SEE NOTE #6 3/4"FDR(55)-1 AO 3

FDR AO 4

FDR RED. (TYP.

2 PLCS.)

G11-F003 3/8"PI(1)-ST-(IR-61)-4 3/8"PI(1)-ST-(IR-65)-4 FROM REACTOR RECIRCULATION PIPING LOOP "A" DWG. M530 FROM REACTOR RECIRCULATION PIPING LOOP "B" DWG. M530 C

O G11-004 C

O T

T 4"MWR(62)-1S 4"MWR(63)-1S 3"MWR(62)-1S MWR-V-119 MWR-V-109 3"FDR (46)-1 FDR-1 MWR 3"MWR(63)-1S MWR-V-107A MWR-V-108A 4"MWR(62)-1S (D/12)

(C/10)

MWR-FLX-2A MWR-FLX-1A RRC-4S MWR-1S MWR-V-107B MWR-V-108B RRC-4S MWR-1S (C/8)

(D/6)

MWR-FLX-1B 4"MWR(62)-1S 4"MWR(63)-1S 4"MWR(62)-1S-1 (CHEM CLEANING CONN.)

4"MWR(63)-1S-1 (CHEM. CLEANING CONN)

MWR-V-124(L.C.)

MWR-V-125(L.C.)

3/4"MWR(55)-1S-2 (TEST CONN.)

MWR-V-619(V) 4"FDR-1 4"FDR-1 4"FD(30)-1 (TYP.)

3/4"FD(30)-1 (TYP.)

CONTRACT 215 CONTRACT 206 CONTRACT 206 DRYWELL FLOOR EL. 492'-8 1/4" S.S. SUMP LINER TRENCH TRENCH DIAPHRAGM FLOOR TO CONTAINMENT VESSEL SEAL.

WATER LEVEL EL. 492'-4 1/4" EL. 487'-8 1/4" 215 213 FABRICATED BY 215 INST'D BY 213A DRAIN CAP EL. 436'-3" MWR-V-620(V)

CONTR. 215 CONTR.

213 CONTR.

215 SEE NOTE 10 CONTRACT 215 CONTRACT 206 FLOOR DRAIN SUMP 4"FDR(48)-1S-1 SEE NOTE 6 FOR CONTRACT SEE DWG. S822 DET. D-173 FABRICATED BY CONTR. 215 INSTALLED BY CONTR. 213B PERFORATED PIPE FAB'D BY 215 INST'D BY 213B FAB'D &

INST'D 213B POOL SUPPRESSION 2"FDR(48)-1-3 2"FDR(48)-1-2 WATER LEVEL EL. 466'-4 3/4" MAX.

3"FDR(48)-1-1 3"FDR(48)-1-2 FABRICATED &

INST'D BY 213B INST'D BY 213A FABRICATED BY 215 3"FDR(48)-1-2

-1

-1S CONT 206 FAB'D &

INST'D BY 213A 2"FDR(48)-1-5 FAB'D BY 215 INST'D BY 213B 3"FDR(48)-1 2"FDR(48)-1-4 FAB'D 215 INST'D 213B FAB'D & INST'D BY 213B N.O.

CONTR.

206 FOR CONTRACT SEE DWG. S822 DET. D-173 3/4"MWR(55)-1S-1 (TEST CONN.)

ISOLATION SIGNAL A,F L.C.

L.C.

3" 4"FDR-1 TO DETERGENT DRAIN TANKS DWG. M533-1 (G/15)

TO CHEMICAL WASTE TANKS DWG. M533-1 (G/6)

TO FLOOR DRAIN COLLECTOR TANK DWG. M531 (E/13)

FSAR FIG.

B. L. STAFFORD 8-21-00 73 4-29-02 REDRAWN AND REVISED PER 01424-016, 01485-022, 01522-006.

4WT/BLS KL DRJ 2"

4"MWR(63)-1S

-1S 1"x 1/2" AREA DRAINS OF COL. 5 OF COL. 5) 206A CONT. 6426 CONT. 206A CONT. 6426 CONT. 206A CONT. 206A CONT. 6426 FDR-SF-2 FDR-SF-1 X-24 X-94 X-95 AH AHH AH AHH AH REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

3/4"TEST CONN.

G11-F576B G11-N004B G11-N005B G11-M001B G11-K003B G11-K003D 1"BEDPLATE DRAIN RRC-P-1B DWG. M530 (C/7)

G11-F575 G11-N004A G11-N006A E31-R605A (NOTE 11)

(NOTE 11)

MWR-FLX-2B (NOTE 11)

(NOTE 11) 6"FDR(45)-1 CONT. FROM DWG.

M545-3 (K/10) 6"FDR(44)-1 CONT. FROM DWG.

M545-3 (K/10) 6"FDR(43)-1 CONT. FROM DWG.

M545-3 (K/10) 6"FDR(42)-1 CONT. FROM DWG.

M545-3 (K/9) 3"MWR(30)-1S CONT. FROM DWG.

M545-3 (K/8) 3" CS SS MWR-1S FDR-1 M525-2 (E/10) 74 11-14-03 CORRECTED INCORPORATION OF 215-M-8409 (D/6)

DMS HL SRP SEE DETAIL "A" (ZONE A/15)

FDR-V-221 FDR-V-222 FDR-V-219 FDR-V-220 (SEE NOTE 16)

(SEE NOTE 16)

(SEE NOTE 17)

DETAIL "A" (ZONE D/14-15) 16.

17.

(SEE NOTE 18)

(SEE NOTE 18)

VALVES FD-V-36 & FD-V-37 PROVIDE A SECONDARY CONTAINMENT ISOLATION BOUNDARY WHEN THE REACTOR BUILDING RAILROAD BAY DOORS ARE OPEN ZONE (B/3)

EXCEPT AS NOTED IN NOTES 6, 10, 16 & 17, ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DRAWING INCLUDED IN CONTRACT 205 & 206 ARE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II+

SEISMIC CATEGORY 1M CODE GROUP D SUMP PUMPS FDR-P-1A; FDR-P-1B; FDR-P-2; FDR-P-3A; FDR-P-3B; FDR-P-4; AND ALL THE DISCHARGE PIPING FROM PUMPS ARE IN SCOPE OF CONTRACT 215.

ALL PIPING INSIDE PRIMARY CONTAINMENT, EXCEPT AS NOTED, IS IN CONTRACT 215.

ALL PIPING, VALVES, & ASSOCIATED COMPONENTS ON THIS DRAWING ARE INCLUDED IN CONTRACT 206 EXCEPT WHERE CONTRACT INTERFACES ARE DENOTED BY:

(DELETED)

PIPING & ASSOCIATED COMPONENTS IN SUBSYSTEM FDR(48) UPSTREAM OF VALVE FDR-V-4 (EXCEPT 3 FT OF 2"FDR(48)-1 FROM DIAPHRAGM FLOOR SEAL WHICH DOES NOT REQUIRE HYDROTEST OR CODE STAMP) ARE CLASSIFIED AS FOLLOWS:

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP B

  • DENOTES INSTRUMENTS SUPPLIED WITH EQUIPMENT.

ALL INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.

FROM FIRST WELD INSIDE CONTAINMENT UP TO & INCLUDING TEST CONN. BOUNDARY OUTSIDE CONTAINMENT, PIPING MWR(62) &

MWR(63) ARE CLASSIFIED AS FOLLOWS:

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP B FLEX CONN'S ARE INSTALLED ONLY DURING USE. LINE IS NORMALLY BLIND FLANGED (DELETED)

(DELETED)

ALL INSTR. LINES ARE DESIG-

-NATED BY CODE & LINE NUMBER A. EXAMPLE: LINES ORIGINATING OUTSIDE CONTAINMENT.

SECONDARY CONTAINMENT ISOLATION VALVES FDR-V-219, FDR-V-220, FDR-V-221 & FDR-V-222 ARE CLASSIFIED AS FOLLOWS (ALSO SEE NOTE 17 AND DETAIL "A" - ZONE A/14):

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP C 3" FDR (40)-1 & 3" FDR (41)-1 BETWEEN VALVES FDR-V-219, FDR-V-220, FDR-V-221 &

FDR-V-222 ARE CLASSIFIED AS FOLLOWS (ALSO SEE NOTE 16 AND DETAIL "A" - ZONE A/14):

QUALITY CLASS II+

SEISMIC CATEGORY I CODE GROUP D ALL VALVES SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE.

ALL VALVES SUFFIXED WITH A (D)

DENOTE A 3/4" DRAIN VALVE.

ALL VALVES SUFFIXED WITH A (TH)

DENOTE A THROTTLED VALVE.

18.

THE ATTACHED PIPING AND SUPPORTS HAVE BEEN ANALYZED TO SEISMIC CATEGORY I CRITERIA TO AN ANCHOR OR THROUGH AN OVERLAP REGION AS REQUIRED IN MES-3.

(SEE DETAIL A - ZONE A/14)

(SEE NOTE 18)

(SEE NOTE 18) 75 4-25-05 REV PER 03762 (H/14).

JFT HL SRP PIPING VALVES AND FITTINGS IN THIS AREA ARE STAINLESS STEEL.

19.

3"C.O. AND 1" PIPE PLUG FDR-V-15 FDR-V-3 FDR-V-4 SEE NOTE

  1. 19 SEE NOTE #19 76 6-24-05 REV PER 02795-201 (A/14-15; B-D/1; C-D/14-15; D/4, 6; F-G/1-2; H/1; J/1-2; K/1), 02968-201 (B/1; D/6-7)

H.AL HL DRJ 77 9-1-05 REV PER 03813-300 (B-C/8)

H.AL BLS DRJ 78 9-19-05 CORRECTED INCORP 03813-300 (B/7-8)

H.AL KB SRP