Drawing M512-1, Rev 37, Flow Diagram Diesel Oil & Miscellaneous Systems Diesel Generator Building
ML053270096
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 03/04/2004
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M512-1, Rev 37
Download: ML053270096 (1)


Text

1"DO(4)-1-2 1"DO(4)-1-1 1"DO(5)-1-2 CONTINUED ON DRAWING M512-4 (ZONE F/4)

  • SEISMIC MOUNTING ONLY 21.

THESE DIESEL LUBE OIL PRESSURE SWITCHES ARE SPARED IN PLACE.

1" 1/2" 1"

1" 1"

1" 1/2" 1/2" 1/2" 3/4" DSA(2)-2 NOTE 17 NOTE 1 NOTE 17 NOTE 1 1/2" DSA(4)-2 OVERFLOW TO LUBE OIL SUMP EAST WEST 2" DSA(3)-2 2" DSA(3)-2 LUBE OIL 1/2" SAMPLE CONN 6"

6" 6"

8" SW(73)-1 8" SW(72)-1 1" DCW(6)-1 3/4" NATURAL KEEP WARM CIRCLINE 1 1/2" 1"

LOWER NORMALLY FULL UPPER NORMALLY EMPTY ENGINE SHUTDOWN 1 1/2" LUBE OIL DRAIN 3'-0" BLEED RETURN 5/8" TUBE OPEN 10 PSI NOTE 15 3/4" DSA(3)-2 CONTRACT 215.

VENT HIGH POINT ENG START SOLENOID PRESS LOCKOUT ON RISING 1 1/2" 1 1/2" 1.

ALL VALVES SUFFIXED WITH A (V) DENOTE A VENT VALVE.

ALL VALVES SUFFIXED WITH A (D) DENOTE A DRAIN VALVE.

ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.

2.

3.

LEGEND:

II I*

D DSA PIPING & EQUIPMENT REFERRED TO BY THIS NOTE 17.

18.

THE DIESEL LUBE OIL (DLO) SYSTEM FOR DG-ENG-1A & 1B IS A ARE CLASSIFIED:

DUPLICATE OF STEWART & STEVENSONS VENDOR DRAWING NUMBER 209 (CVI NUMBER 53-00,53) AS MODIFIED BY POWER SYSTEMS DRAWING 19.

(DELETED) 20.

THE DIESEL LUBE OIL PRESSURE SWITCHES ARE INSTALLED BUT JUMPER IS INSTALLED TO BYPASS THEM. SEE ZONES D1 AND E15 6911R03002 SHEET 1 THRU SHEET 4 (CVI NUMBER 332-00,1,1 THRU 332-00,1,4 RESPECTIVELY).

QUALITY CLASS CODE GROUP SEISMIC CATEGORY 15.

ALL ITEMS REFERRING TO THIS NOTE ARE INSTALLED WITHIN THE FILTER MANIFOLD.

16.

(DELETED)

CODE BREAK DEFINITIONS FOR THERMOWELLS ARE SHOWN ON 14.

DRAWING M610 "INSTALLATION OF THE THERMOWELLS AND SAMPLE PROBES".

(DELETED) 13.

DCW-HX-1C IS SUPPLIED BY CONTRACT 2 AND IS ASME SECTION VIII 12.

DIVISION 1, DCW-HX-1A1, 1A2, 1B1, 1B2 WERE SUPPLIED BY CONTRACT 53 AND ARE ASME III, 3.

II II D

ALL DIESEL OIL(DO) PIPING AND ASSOCIATED COMPONENTS ON THIS 11.

DRAWING INCLUDED IN CONTRACT 215 AND REFERRED TO BY THIS NOTE ARE CLASSIFIED:

QUALITY CLASS CODE GROUP SEISMIC CATEGORY 9.

(DELETED)

(DELETED) 10.

7.

ALL ITEMS MARKED

  • ARE FURNISHED WITH ASSOCIATED I

II I

I D

D+

ALL PIPING COMPONENTS AND INSTRUMENTATION SHOWN WITHIN THE ALL DIESEL OIL (DO) PIPING AND ASSOCIATED COMPONENTS 8.

22.

CONFINES OF THE ENGINE SKID OR AIR RECEIVER SKID ARE ON THIS DRAWING INCLUDED IN CONTRACT 215 AND REFERRED SUPPLIED BY THE DG SUPPLIER AND ARE:

TO BY THIS NOTE ARE CLASSIFIED:

QUALITY CLASS QUALITY CLASS CODE GROUP CODE GROUP SEISMIC CATEGORY SEISMIC CATEGORY EQUIPMENT TAG NUMBER WITH SUFFIX A1 REFERS TO NUMBER 1 6.

ENGINE OF DIESEL GENERATOR DG-ENG-1A. SUFFIX A2 REFERS TO NUMBER 2 ENGINE OF DIESEL GENERATOR DG-ENG-1A.

SUFFIX B1 REFERS TO NUMBER 1 ENGINE OF DIESEL GENERATOR DG-ENG-1B AND SUFFIX B2 REFERS TO NUMBER 2 ENGINE OF DIESEL GENERATOR DG-ENG-1B.

DELETED 5.

ALL PIPING AND FITTINGS FOR DE(1)-1 AND DE(2)-1 ARE 4.

SUPPLIED BY CONTRACT 53 AND SUPPORTED AND ERECTED BY (DELETED) 3.

I I

C FOR CONTRACT 215 ALL DIESEL OIL (DO) PIPING AND ASSOCIATED COMPONENTS ON 2.

THIS DRAWING EXCEPT AS NOTED IN NOTES 11 AND 22 ARE CLASSIFIED:

QUALITY CLASS CODE GROUP SEISMIC CATEGORY I

I D

TO 22" EXHAUST LINE (ZONE H/10)

DETAIL "A" LOOP SEAL TYPICAL OF FIVE (ONE PER EACH DIESEL EXHAUST) 1" DE(56)-1 1/4" VENT HOLE 1/2" DSA(2)-2 1 1/4" DE(6)-1 1" DCW(2)-1 OPEN 1 1/4" FILL EXPANSION TANK VENT 2"

DCW-1 SW-1 1" SW(72)-1 CONT'D ON DWG M524-1 (ZONE J/7) 17 NOTE NOTE NOTE NOTE 1

3/4" DSA(2)-2 1/4" DSA(3)-2 17 1

DCW SW DCW SW 3/4" DSA(6)-2 3/4" DSA(6)-2 NOTES:

ALL DIESEL STARTING AIR (DSA), DIESEL COOLING WATER (DCW),

1.

AND DIESEL EXHAUST (DE) PIPING AND ASSOCIATED COMPONENTS ON THIS DRAWING INCLUDED IN CONTRACTS 2, 53 AND 215 EXCEPT AS NOTED IN NOTE 17 ARE CLASSIFIED:

QUALITY CLASS CODE GROUP SEISMIC CATEGORY COOLING WATER FROM ENGINE 3/4" AIR BOX DRAIN TO PORTABLE FIRE RATED TANK 24" DE(4)-1 (ZONE B/13) 22" DE(3)-1 TO ATMOSPHERE 1" DE(56)-1 SEE DET "A" COOLING WATER TO ENGINE COOLING WATER TO ENGINE 3/4" DCW(56)-1 DCW-1 DW-1S 1" DW(23)-1S CONT'D ON DWG M517 (ZONE B/3)

HI TEMP SHUT DOWN PRESSURE CAP 7 PSI SEE DWG M524-1 (ZONE J/7) 3/4" VENT SEE DWG M524-1 (ZONE H/7)

OVERSPEED TRIP HOUSING ENGINE SUMP HIGH CAPACITY OIL PAN SEE NOTE 15 OPEN 40 PSI 1/2" TUBING ENG OIL LEVEL DURING STANDBY TUBE SIDE 1"

1 1/4" 0.06" ORIFICE TO TURBOCHARGER 1/2" TUBING 1/2" TUBE FILTER VENT 1/2" TUBE OIL COOLER VENT DIPSTICK OVERFLOW SYPHON BREAK 1/2" TUBE FILTER BYPASS TO PISTON COOLING MANIFOLD MAIN LUBE OIL HEADER TO GOVERNOR BOOSTER ENGINE AIR START MOTORS (TYP 4) 1 1/2" 1 1/2" FSAR FIG (TYP)

NOTE 15 OPEN 10 PSI INJECTOR ORIFICE EXCESS FUEL FLOW FILTERS (TYP) 1 1/4" OPEN 65 PSI NOTE 15 ED 24 KL CORRECTED INCORPORATION OF 55-1800-0A-301 (E/1).

FLOW DIAGRAM DIESEL OIL &

MISCELLANEOUS SYSTEMS DIESEL GENERATOR BUILDING A

B C

D E

F G

H J

K A

B C

D E

F G

H J

K 4

5 7

6 8

9 10 11 12 13 14 15 2

3 1

4 5

7 6

8 9

10 11 12 13 14 15 2

3 REV DATE DRWN CHKD ENGR REMARKS REV DATE DWN CHK APVD HL 28 REVISED PER 94-10-102-0002 (G-H/7)

DESCRIPTION REV DATE DWN CHK APVD DESCRIPTION DR JACOBSEN SR PAYNE JR MILLER JC MOWERY 4-22-88 4-22-88 4-11-88 3-24-88 N/A 37 M512-1 TITLE DATE SIGNED APPROVED DESIGN CHECKED DRAWN SCALE REV.

DRAWING #

TE 3K DCW TE 3J DCW DSA-V-72 DSA-V-2A DSA-V-2B AIR COMPRESSOR DSA-C-2C DSA-ENG-C/2C DSA-V-71 DSA-HX-2 DSA-V-73 DSA-DY-2 dPI 1C DSA DSA-F-3 DO-F-4 DO-FLX-21 OPEN 10 PSI DO-V-17 DO-ST-4 DO-FLX-7 DO-FLX-6 DO-FLX-34 DO-FLX-32 DO-FLX-33 DO-FLX-5 ENGINE DRIVEN DO-P-5 DC MOTOR DRIVEN DO-P-6 DUPLEX FILTER DO-F-3 DUPLEX STRAINER DO-ST-3 DO-FLX-22 DO-FLX-23 PI 12 DSA PS 8

DSA DSA-LOC-4C1/2 DSA-ST-1C/2 DSA-V-80 DSA-LOC-4C1/1 DSA-ST-1C/1 DSA-M-6C1/2 DSA-FLX-12C1 DSA-M-6C1/1 DSA-FLX-11C1 LUBE OIL COOLER DCW-HX-2C DLO FG 4

DLO-V-19 DLO-V-13C DLO-F-3 AL A

PUMP SOAK BACK AC DRIVEN DLO-P-12 PUMP SOAK BACK DC DRIVEN DLO-P-10 SCAVENGING LUBE OIL PUMP DLO-P-9 DLO-ST-2C DLO-ST-1C STRAINER DRAIN DLO-V-12C DLO-RV-1C DLO-ST-3 DLO-V-723 OPEN AT 30 PSI DLO-V-21 DLO-ST-6 OPEN AT 75 PSI DLO-V-18 AUX LUBE OIL TURBO FILTER DLO-F-1 DLO-FLX-9 DLO TI 10 DLO FG 6

DLO FG 5

DLO 6

RO PS 20 DLO DLO-FLX-2 PI 16 DLO DLO-FLX-3 TURBO LUBE OIL FILTER DLO-F-5 CIRC PUMP 6 GPM AC DRIVEN DLO-P-6 AL COOLING PUMP PISTON DLO-P-8 OIL PUMP MAIN LUBE DLO-P-7 DLO-V-20 LS 17 DLO AH PS 26 DLO TS 10 DLO TS 9

DLO TS 11 DLO TI 9

DLO DLO 4

RO DLO 5

RO TS 8

DCW IMMERSION HEATER DCW-H-1C DCW-FLX-9 DCW-FLX-7 TI 6

DCW DCW-FLX-4 (WEST)

DCW-P-1C DCW-FLX-3 (EAST)

DCW-P-2C (SEE NOTE 12)

DCW-HX-1C TUBE SIDE DCW-TCV-2 ED DCW-TK-1C EXPANSION TANK DCW-V-711 DCW-V-712 LG 2

DCW TS 4

DCW TS 5

DCW TI 4

DCW AH DE-FLX-3 DE-ES-1 AIR INTAKE FILTER DE-F-1 DE-FLX-4 DSA-V-54B DSA-V-54A DO-FLX-26 DO-FLX-27 DO-RV-14 (ON PUMP)

DO-FLX-28 PS 1

DO AL DO-FLX-31 PS 2

DO AL DO-FLX-30 DO-FLX-29 PI 4

DO PS 3

DO AL DSA-FLX-6B ED DSA-V-1B DE-FLX-5 HYDRAULIC UNLOADER DSA-V-724B COMPRESSOR UNLOADING VALVES DSA-V-726A & 726B DSA-V-605(D)

DE-V-603 PS 35 DSA AIR COMPRESSOR DSA-C-1C DSA-M-C/1C DSA-FLX-6A ED ED DSA-V-1A DSA-V-713 HYDRAULIC UNLOADER DSA-V-724A COMPRESSOR UNLOADING VALVE DSA-V-725A PS 34 DSA AL PS 15 DSA AIR RECEIVER DSA-AR-1C DSA-V-75 DSA-RV-13 PI 7

DSA DSA-V-721A DSA-V-718 DSA-V-720 DSA-V-721C ED AL PS 16 DSA AIR RECEIVER DSA-AR-2C DSA-V-76 DSA-RV-14 PI 8

DSA DSA-V-721B DSA-V-717 DSA-V-719 DSA-V-721D DSA-V-81A DSA-V-81B DSA-V-3A DSA-V-3B DSA-V-4A DSA-V-4B DSA-V-715 AL TS 6

DCW LS 15 DCW AL DCW-FLX-8 DCW-FLX-5 DCW-FLX-15 DCW-FLX-11C DCW-FLX-6 DCW-V-5 1/4" DRAIN DLO-FLX-1 PS 37 DLO DLO-FLX-4 DLO-FLX-5 DLO-FLX-6 PS 30 DLO AL PS 24 DLO 900 RPM ENGINE IDLE AL PS 22 DLO DSA-FLX-1A DSA-FLX-1B PS 12 DSA DSA-V-82B DSA-V-82A DSA-V-83A DSA-V-83B PI 11 DSA PS 11 DSA DSA-V-7C1/1 PS 7

DSA DSA-M-6C1/3 DSA-FLX-11C2 DSA-M-6C1/4 DSA-FLX-12C2 DSA-V-7C1/2 DE-IS-2 DSA-V-85 DSA-V-84 DSA-V-9A ED DSA-V-9B ED (NOTE 8)

HPCS DIESEL GENERATOR SKID DG-ENG-1C ED D0-FLX-25 DLO-FLX-8 A

A DCW-FLX-12 DCW-FLX-11 PS 27 DCW PS 36 DCW AL DSA-V-78 DSA-V-74 DO-RV-56 DLO-V-15 DLO-V-719C DLO-V-722C DLO-FLX-13 DLO-FLX-7C DLO-FLX-11C DLO-V-717 DLO-V-716 AL AL PS 21 DLO PS 8

DLO AL AH DCW-FLX-16 DCW-FLX-12C DCW-V-15(D)

SW-FLX-4 (REFERENCE)

SW-FLX-3 (REFERENCE)

DLO-V-22 DSA-SPV-5C1/1 DSA-SPV-5C1/2 DSA-V-2C1/2 DSA-V-2C1/1 DSA-V-716 DSA-V-714 MX 1C DSA PI 9C DSA DSA-V-729C DO-FLX-20 DLO-FLX-12 DLO-V-720C DLO-V-718C RMS M

M DSA-V-3C1/2 RELAY AIR VALVE DSA-V-3C1/1 RELAY AIR VALVE DCW-V-12 DCW-V-6 DSA-V-7A DSA-V-7B DSA-PCV-37B DSA-PCV-37A DSA-PCV-1C DSA-PCV-2C DSA-V-737 DSA-V-736 DO-V-67C1 DO-V-68C1 DSA-V-731C DSA-V-730C 10-22-93 HL SW QC I QC II NOTE 15 QC II QC I QC I QC II D FOR CONTRACT 2 AND 53 CODE GROUP DG SKID SUPPLIER.

ON SHEETS 2 AND 3.

SEE ZONES D2 AND D15 ON SHEETS 2 AND 3.

QC I QC II REVISED PER 93-09-044-0002 (J-K/6), 93-09-044-0003 (E/15), 93-09-044-0004 (D/4-5),

93-09-044-0005 (H/4-5), 93-09-044-0015 (G-H/10-12), 93-09-044-0016 (J/8), 93-09-044-0028 25 HL (G-H/1-2), 93-09-044-0030 (H-K/1-2).

QC I, CODE D QC I, CODE C 11-5-93 KL JD 26 REVISED PER 55-3046-0A-301 (F-G/10-11)

HL AIR START MOTOR CONTROL LOGIC AIR START MOTOR CONTROL LOGIC 6-17-94 PAA JHD 27 REVISED PER 94-05-169-0003 (D/6)

HL 7-1-94 PAA JHD 11-10-94 KL WHK DSA-V-744 DSA-QDC-9 DSA-QDC-8 DSA-V-743 29 REVISED PER 92-0178-5F-332 (H-J/6,8)

HL 12-8-94 KL JD 30 REVISED PER 89-0227-0A-A26 (K/7)

HL 1-26-95 PAA TWM MJH REVISED PER 94-10-061-0003 (J/8, K/6) 31 2-16-95 HL RC MECH:\\12-1.DWG DSA-V-104C 32 REVISED PER 91-0298-0A-306 (J/4)

PAA 5-11-95 HL RC DSA-RV-15 3/4" DSA(6)-2 DSA-RV-16 DSA-V-747 DSA-QDC-11 DSA-V-748 DSA-V-746 DSA-V-745 DSA-QDC-10 33 5-20-97 REVISED PER 89-0212-0A-302 (J/4-5), 92-0178-3D-300 (H/3-5).

KL HL DLE 1/2" DSA(2)-2 34 9-16-99 REVISED PER 99-07-003-0003 (E-G/7-8; H-K/4-7).

HL KL SRP KL BLS SRP 35 1-4-01 REVISED PER 0764-002 (C/12).

COLUMBIA GENERATING STATION 36 3-14-02 REVISED PER 1486-007 (H/15, J/13)

DMS KL SRP 37 3-4-04 REVISED PER 01935-003 (D/14)

H.AL HL DRJ