77 M510-1 N.T.S.
SIGNATURE DATE TITLE 11 10 9
8 7
6 5
4 3
2 A
B C
D E
F G
H J
K APVD CHK DWN DESCRIPTION DATE REV REV.
DRAWN CHECKED DESIGN APPROVED SCALE DWG NO.
K J
H G
F E
D C
B A
1 2
3 4
5 6
7 8
9 10 11 REV DATE DESCRIPTION DWN CHK APVD APVD CHK DWN DESCRIPTION DATE REV COLUMBIA GENERATING STATION FLOW DIAGRAM CONTROL AND SERVICE AIR SYSTEM R.B. CLEAVENGER 7-24-92 TOP TIER FSAR FIG.
CAS-AR-2A LG 1A TS HDT/1A C
C1029 HIGH DISCH TEMP SHUTDOWN TI 1A CAS-V-288A(D)
CAS-RV-118A CAS-MS-4A CAS-F-24A CAS-V-289A DPI 27A DPS 2A PS HDP/1A C
C0472 PRESS SHUTDOWN HIGH DISCH PI 29A DPS 3A DPI 24A A
TROUBLE CAS-HX-7A OIL COOLER CAS-V-284A AFTER COOLER CAS-HX-6A CAS-V-285A CAS-ES-1A CAS-PRV-10A CAS-F-23A N.E.
F.C.
N.O.
DPS 1A DPI 25A BEARING OIL PS LOP/1A C
C1026 SHUTDOWN LOW OIL PRESS M
100HP CAS-M-C/1A C C1035 M
1/4HP CAS-FN-1A CAS-M-FN/1A 1 1/4" CJW(2)-1 SEE DWG SEE DWG 1 1/4" CJW(22)-1 RMS C/1A A
TRIP MS CAS-MS-2A CAS-T-11A ED FROM DWG 3/4" CJW(56)-1 3/4" CAS(56)-1 CAS-V-282A(D)
AIR OUT CAS-V-278A 3/4" CAS(1)-1 AIR INTAKE 400 CFM AIR COMPRESSOR CAS-C-1A M942 (B/8)
M942 (B/8-9)
M942 (C/8-9)
PS AUTO/1A AUTO START ON LOW LINE PRESSURE IF STANDBY DWG M510-4 (H/5)
FROM CAS-V-443 FROM CJW-PS-LWP/1A DWG M942 (C/10)
MS CAS-HX-3A AIR-AIR M
C ACCUMULATOR CAS-CU-1A CAS-HX-5A PS 8A PI 27A PI 26A PS 7A RMS DY/2A LIQUID RECEIVER REFR.-AIR CAS-HX-4A CAS-MS-3A AIR DRYER CAS-DY-2A 1" CJW(2)-1 SEE DWG M942 (C/7)
DWG M942 (C/7) 1" CJW(22)-1 SEE 1/4" CAS(56)-1 DWG M942 (B/7) 3/4" CJW(56)-1 FROM ED 3/4" CAS(56)-1 2 1/2" CAS(2)-1 CAS-F-18A CAS-F-19A CAS-F-20A DPI 28A DPI 29A DPI 30A 3" CAS(2)-1 ED 1/2" CAS(56)-1 2" CAS(1)-1 4" CAS(1)-1 2" CAS(1)-1 4" CAS(1)-1 CAS-V-299A 4" CAS(2)-1 2 1/2" CAS(1)-1 4" CAS(2)-1 6" CAS(2)-1 CAS-V-279A WARM AIR FROM COMPRESSOR CAS-V-279B 4" CAS(2)-1 CAS-V-299B 3" CAS(2)-1 DPI 30B DPI 29B DPI 28B CAS-F-20B CAS-F-19B CAS-F-18B 2 1/2" CAS(2)-1 3/4" CAS(56)-1 ED 3/4" CJW(56)-1 FROM DWG M942 (E/7) 1/4" CAS(56)-1 1" CJW(22)-1 SEE DWG M942 (F/7)
DWG M942 (F/7) 1" CJW(2)-1 SEE AIR DRYER CAS-DY-2B CAS-MS-3B CAS-HX-4B REFR.-AIR LIQUID RECEIVER RMS DY/2B PS 7B PI 26B PI 27B PS 8B CAS-HX-5B CAS-CU-1B ACCUMULATOR C
M AIR-AIR CAS-HX-3B MS WARM AIR FROM COMPRESSOR DWG M510-4 (F/4) 6" CAS(2)-1 TO ALL VALVES SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.
ALL VALVES SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE.
1.
2.
LEGEND:
(DELETED) 7.
6.
THESE COMPUTER POINTS ARE NOT USED.
d - SA(1)-1 DOWNSTREAM OF AND INCLUDING THE LAST CONTAINMENT ISOLATION VALVE (AS SHOWN ON M510-3 ZONE H/7):
QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP B CODE GROUP B SEISMIC CATEGORY I QUALITY CLASS I (AS SHOWN ON M510-2 ZONE H/11):
c - CAS (5) DOWNSTREAM OF THE OUTER CONTAINMENT ISOLATION VALVE NOTES:
b - CAS (5) DOWNSTREAM OF AND INCLUDING THE LAST SYSTEM ISOLATION VALVE (AS SHOWN IN DETAIL B ON M510-2A ZONE H-K/7-9):
QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP C HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.
a - ALL PIPING EXCEPT AS NOTED IN b, c AND d BELOW:
QUALITY CLASS II SEISMIC CATEGORY II CODE GROUP D 5.
(BREAK POINTS ARE INDICATED ON THE FLOW DIAGRAM):
AND DIESEL GENERATOR BUILDINGS SHALL BE CLASSIFIED AS FOLLOWS IN THE CONTROL AND SERVICE AIR SYSTEM IN THE REACTOR, CONTROL ALL PIPING, VALVES AND ASSOCIATED COMPONENTS ON THIS DRAWING CODE GROUP D SEISMIC CATEGORY II QUALITY CLASS II DIESEL GENERATOR BUILDINGS:
ARE CLASSIFIED AS FOLLOWS EXCEPT IN THE REACTOR, CONTROL AND ALL PIPING, VALVES AND ASSOCIATED COMPONENTS ON THIS DRAWING 4.
VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.
ALL INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE 3.
2.
ALL EPN'S LOCATED WITHIN SKID OUTLINE OR THOSE ITEMS MARKED 1.
OR "SA" AS APPLICABLE, UNLESS SPECIFICALLY NOTED OTHERWISE.
ALL INSTRUMENTS ON THIS DRAWING TO BE IDENTIFIED BY PREFIX "CAS" MARKED " " ARE FURNISHED W/ ASSOCIATED EQUIPMENT.
4" CAS(1)-1 REVISED AND REDRAWN PER 89-0266-0C-255, 89-0266-0C-A42, 89-0266-0C-A43, 89-0266-0C-A50, 89-0266-0C-B09, 89-0266-0C-B10, 89-0266-0C-B11, 89-0266-0C-B17, 89-0266-0C-B18, 89-0266-CAS-V-609A(D) 1/4" 1/4" CAS-V-609B(D)
CAS-V-736A MON 1C A
ALARM ON HI CO C
C0614 C
C0627 ALARM ON HI CO A
MON 1B MON 1A A
ALARM ON HI CO C
C0111 0C-B19, 89-0266-0C-B20, 89-0266-0C-B21, 89-0266-0C-C02, 89-0266-0C-C03, 89-0266-0C-C19 70 RC CAS-V-736D AND 55-2048-0A-200.
F.C.
PAA JFB P.A. ANDERSON 7-24-92 F.A. CARLYLE 7-24-92 J.F. BROWER 7-24-92 7-24-92
- 3. ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.
REV PER 55-1800-0A-301 (G/1-2).
71 KL RC BDN 8-21-92 72 REV PER 55-1586-0B-301 (C/3,6,10,K/3).
PAA 10-02-92 RC TWM CAS-ST-11A CAS-V-305A CAS-SV-1A ND CAS-ST-11B CAS-V-305B CAS-SV-1B ND 73 REV PER 55-2427-0A-300 (H/11), 55-2427-0A-301 (H/7).
HL 8-13-93 KL JFB 74 REV PER 55-2930-0A-300 (E/4,7), 55-2930-0A-301 (E/11).
HL 12-3-93 PAA JCM 75 REV PER 55-2887-0A-300 (J/1).
HL 12-10-93 PAA JFB CAS-FCV-3A CAS-ST-7A CAS-ST-8A FG 4A FG 3A CAS-F-27A PI 30A PS REG/1A (AUTOMATIC)
CAS-F-28A CAS-V-611A CAS-V-610A FILL CONN.
DWG M510-4 (H/5)
FROM CAS-V-443 AIR COMPRESSOR CAS-C-1B CAS-V-289B CAS-MS-4B CAS-V-288B(D)
CAS-AR-2B SHUTDOWN AUTO START ON LOW LINE PRESSURE IF STANDBY DWG M942 (F/10)
FROM CJW-PS-LWP/1B TRIP A
RMS C/1B CAS-V-610B CAS-V-611B PS AUTO/1B FG 3B FG 4B C C1036 CAS-M-C/1B LOW OIL PRESS PS LOP/1B C
C1027 100HP M
CAS-M-FN/1B CAS-FN-1B 1/4HP M
DPS 2B DPI 27B CAS-F-24B BEARING OIL FILL CONN.
TEMP SHUTDOWN HIGH DISCH TI 1B LG 1B TS HDT/1B C
C1030 F.C.
CAS-FCV-3B N.O.
CAS-ST-7B DPI 25B DPS 1B CAS-F-21B CAS-PRV-10B N.E.
CAS-V-285B CAS-ES-1B HIGH DISCH PRESS SHUTDOWN C
C0472 CAS-ST-8B CAS-RV-118B PS HDP/1B CAS-F-23B A
TROUBLE T
CAS-F-28B F.C.
(AUTOMATIC)
CAS-T-11B CAS-HX-6B AFTER COOLER OIL COOLER CAS-HX-7B DPI 24B PI 29B CAS-V-284B DPS 3B CAS-F-27B PS REG/1B PI 30B CAS-MS-2B MS M942 (E/8-9)
M942 (F/8-9) 1 1/4" CJW(22)-1 SEE DWG 3/4" CAS(56)-1 ED SEE DWG 1 1/4" CJW(2)-1 AIR INTAKE 400 CFM CAS-V-736B CAS-V-278B CAS-V-282B(D)
AIR OUT 3/4" CAS(1)-1 DWG M510-4 (H/5)
FROM CAS-V-443 AIR COMPRESSOR CAS-C-1C CAS-V-289C CAS-MS-4C CAS-V-288C(D)
CAS-AR-2C SHUTDOWN AUTO START ON LOW LINE PRESSURE IF STANDBY DWG M942 (H/10)
FROM CJW-PS-LWP/1C TRIP A
RMS C/1C CAS-V-610C CAS-V-611C PS AUTO/1C FG 3C FG 4C C C1037 CAS-M-C/1C LOW OIL PRESS PS LOP/1C C
C1028 100HP M
CAS-M-FN/1C CAS-FN-1C 1/4HP M
DPS 2C DPI 27C CAS-F-24C BEARING OIL FILL CONN.
TEMP SHUTDOWN HIGH DISCH TI 1C LG 1C TS HDT/1C C
C1031 F.C.
CAS-FCV-3C N.O.
CAS-ST-7C DPI 25C DPS 1C CAS-F-21C CAS-PRV-10C N.E.
CAS-V-285C CAS-ES-1C HIGH DISCH PRESS SHUTDOWN C
C0472 CAS-ST-8C CAS-RV-118C PS HDP/1C CAS-F-23C A
TROUBLE CAS-F-28C F.C.
(AUTOMATIC)
CAS-T-11C CAS-HX-6C AFTER COOLER OIL COOLER CAS-HX-7C DPI 24C PI 29C CAS-V-284C DPS 3C CAS-F-27C PS REG/1C PI 30C CAS-MS-2C MS M942 (H/8-9)
M942 (H/8-9) 1 1/4" CJW(22)-1 SEE DWG 3/4" CAS(56)-1 ED SEE DWG 1 1/4" CJW(2)-1 AIR INTAKE 400 CFM CAS-V-736C CAS-V-278C CAS-V-282C(D)
AIR OUT 3/4" CAS(1)-1 2" CAS(1)-1 M942 (E/8) 3/4" CJW(56)-1 FROM DWG M942 (H/8)
FROM DWG 3/4" CJW(56)-1 CAS-T-14 CAS-T-13 CAS-T-15 ED CAS-T-16 1/2" CAS(56)-1 PS DY/2A (EVAPORATOR)
PS DY/2B (EVAPORATOR) 76 REV PER 94-03-084-0002 (A-F/1-11,H-K/5-10).
PAA 03-25-94 KL DG CAS-V-208B CAS-TCV-1B CAS-V-207B CAS-V-286B CAS-V-287B CAS-TCV-1A T
CAS-TCV-1C T
CAS-V-208C CAS-V-208A CAS-V-287A CAS-V-287C CAS-V-207A CAS-V-207C CAS-V-286A CAS-V-286C CAS-F-21A RO 1A RO 1B RO 1C 77 REV PER 03436-200 (C-E/2-4, 5-7, 9-11).