15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CONTINUED NOTES:
- 12. PIPING REFERRING TO THIS NOTE SHALL BE CLASSIFIED 1. ALL INSTRUMENTATION ON THIS DRAWING TO BE PREFIXED BY CAC AS STATED IN NOTE 6 FOR MATERIAL FABRICATION AND UNLESS SPECIFICALLY NOTED OTHERWISE; i.e.
INSTALLATION ONLY. CODE STAMP NOT REQUIRED.
- 13. CONTRACT 71 FURNISHED INSTRUMENTS ON LOCAL CONTROL IS IDENTIFIED AS CAC-PI-1 K PANEL, WITH SUFFIX NUMBER "1" ARE SHOWN FOR FLOW 1 K DIAGRAM DEFINITION ONLY AND WILL NOT APPEAR ON THE LOCAL CONTROL PANEL. 2. FOR FLOW DIAGRAM LEGEND, SYMBOLS, AND ABBREVIATIONS, DISABLED 14. SEE DRAWING M501.
FLOW CAN BE CALCULATED FOR FE-1B, FE-2A, FE-2B, SEE NOTE 15.
FE-3A, FE-3B, FE-4A & FE-4B BY READING ma SIGNAL DISABLED DISABLED AT SQUARE ROOT EXTRACTOR AND BY CONVERTING TO CFM. 3. MOTOR OPERATED VALVES (A.C. ONLY) ARE WITH SLOW CLOSURE SEE NOTE 15.
SEE NOTE 15.
- 15. ALL ITEMS IN THE CROSSHATCHED AREA ARE PART OF THE TIME (WITH POSITION INDICATOR IN CONTROL ROOM)
HYDROGEN RECOMBINER SYSTEM (CONTAINMENT ATMOSPHERE
- 4. THE UNITS ARE STARTED FROM MAIN CONTROL ROOM. FOR CONTROL-"CAC") WHICH HAS BEEN DISABLED. PRIMARY CONTAINMENT HYDROGEN AND OXYGEN SAMPLING AND RECORDING SYSTEMS VALVES CAC-V-2, -4, -6, -8, -11, -13, -15 AND-17 HAVE BEEN SEE DWG. M543-1 THRU 3.
DE-ENERGIZED AND LOCKED CLOSED. (REF PDC 3539). CONTROL AND INDICATION FOR THE SYSTEM HAS BEEN REMOVED. NITROGEN BLANKET REQUIREMENT FOR THE "CAC" SYSTEM REMAINS IN SERVICE. 5. ALARMS INDICATE LIGHTS ON LOCAL PANEL AND REMOTE (SEE NOTE 12 & 14)
LEGEND ANNUNCIATION.
INTERLOCK WITH INTERLOCK WITH SQRT H2 RECOMBINER H2 RECOMBINER 1. ALL VALVES SUFFIXED WITH A (V) 1B
- 6. ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS (SEE NOTE 12) DENOTE A 3/4" VENT VALVE.
J DRAWING SHALL BE CLASSIFIED AS FOLLOWS: J RMS RMS RMS RMS FT FT 2. ALL VALVES SUFFIXED WITH A (D) QUALITY CLASS I EXCEPT WHERE NOTED 1A 1B DENOTE A 3/4" DRAIN VALVE. SEISMIC CATEGORY I EXCEPT WHERE NOTED CAC-V-301A CAC-V-302A CODE GROUP B EXCEPT WHERE INDICATED AS GROUP C OR D.
- 3. ALL VALVES SUFFIXED WITH A (TH)
AC T DC DC T AC T O O O O DENOTE A THROTTLED VALVE.
EHO MO MO EHO 7. DELETED C C C C T
CAC-V-301B CAC-V-302B
- 8. ALL VALVE TEST CONNECTIONS FOR LINES PENETRATING 1/2"CAC(60)-1-2 1/2"CAC(60)-1-1 1/2"CAC(60)-1-9 1/2"CAC(60)-1-10 4"CAC(2)-1-1 N.C. F.C. N.C./L.C. N.C./L.C. N.C. F.C. 4"CAC(12)-1-1 PRIMARY CONTAINMENT SHALL CONSIST OF 3/4" GLOBE VALVES CAC-V-6 CAC-V-15 WHICH SHALL BE TAGGED CAC-V-800-(NUMBER AS SHOWN) 2 1/2"CAC-FCV-1A 2 1/2"CAC-FCV-1B FE FE 1A 1B 9. INTERFACE CONNECTION NUMBER PROVIDED BY H2 CAC-V-800/47 CAC-V-800/45 CAC-V-800/44 CAC-V-800/19 CAC-V-800/21 CAC-V-800/23 RECOMBINER SKID SUPPLIER.
3/4"CAC(55)-1-1 3/4"CAC(55)-1-3 3/4"CAC(55)-1-5 3/4"CAC(55)-1-2 3/4"CAC(55)-1-4 3/4"CAC(55)-1-6
- 10. ALL PRESSURE AND FLOW INSTRUMENT ROOT VALVES SHALL CAC-V-800/48 CAC-V-800/20 CAC-V-800/22 CAC-V-800/24 CAC-V-800/46 CAC-V-800/43 BE 3/4" GLOBE VALVES UNLESS NOTED OTHERWISE.
H X-99 H
X-97 6"x 4"RED 6"x 4"RED 11. ALL TAGS FOR INSTRUMENT ROOT VALVES WILL BE FURNISHED &
INSTALLED BY OWNER.
DISABLED INSTRUMENT SEE NOTE 15. INSTRUMENT RECIRC. WARM-UP WARM-UP WARM-UP RECIRC. WARM-UP (BLOWER & HEATER)
(SEE NOTE 12 & 14) (BLOWER & HEATER)
RMS RMS RMS (SEE NOTE 12 & 14) RMS RMS RMS TO RHR-MO-134A TO RHR-MO-134B 11A1 10A 9A T 9B 10B 11B1 CONT. ON DWG. T CONT. ON DWG.
M521-1 (F/14) FROM FROM M521-2 (F/6)
SQRT SQRT 4"CAC(11)-1-1 BALANCE OF TS-2A & 3A TS-2B & 3B BALANCE OF 2A KEY LOCK KEY LOCK 2B SYSTEM START-UP ZONE (E/2) 1/2"CAC(60)-1-4 SYSTEM START-UP ZONE (E/14)
RMS RMS RMS RMS D RMS RMS FT FT RMS RMS D RMS RLY RLY RMS SHUTDOWN SHUTDOWN G G CAC-V-18A FI FI GROUP GROUP 2A 2B CAC-V-308A CAC-V-307A 11A2 1ASTO 1ASTA TK/2A 1BSTA 1BSTO FS-6A-LOW TK/2B 11B2 FS-6B-LOW 1/2"CAC(60)-1-12 5A 5B TS-7A-HI T O T O O T O T TS-7B-HI AC DC DC AC TS-5A-HI TS-5B-HI SQRT FI FI SQRT CODE CODE EHO MO MO EHO TS-6A-HI TS-6B-HI C C C C 5A 5A1 EHO CAC-V-307B O EHO 5B1 5B FT 6"x 4"RED CAC-V-308B FT RMS C RMS RMC 5A 2"CAC(2)-1 1/2"CAC(60)-1-3 N.C.
F.C. N.C./L.C. 4"CAC(1)-1-1 N.C./L.C. F.C. N.C.
1/2"CAC(60)-1-11 2"CAC(12)-1 5B RMC CAC-V-17B CAC-FCV-5A CAC-FCV-6A X-96 X-98 CAC-FCV-6B FCV/5A CAC-V-17A 2"CAC(2)-1 2"CAC(12)-1 TYP FOR N2, H2 &
RMC FCV/5B CAC-V-2 CAC-V-11 2 1/2"CAC-FCV-2B 2 1/2"CAC-FCV-2A FE CAC-V-18B BOTTLES V/2A CAC-FCV-22B F.O. F.D.
1 1/2" TEST VENT SCRUBBER CAC-FCV-22A CAC-V-800/40 CAC-V-800/39 CAC-V-800/37 CAC-V-800/13 CAC-V-800/17 2B SCRUBBER O RMC EHO TO HEATER CONTROL CAC-V-800/15 RMC TO HEATER CONTROL EHO RMC CAC-AW-1A CAC-AW-1B CODE GROUP C CAC-V-24A CAC-V-24B
& SHUTDOWN RMC V/2B & SHUTDOWN CODE GROUP C FCV5ALO FT FE 3/4"CAC(55)-1-11 3/4"CAC(55)-1-8 3/4"CAC(55)-1-10 3/4"CAC(55)-1-12 FE FT C FCV5BLO O PI 3/4"CAC(55)-1-7 3/4"CAC(55)-1-9 PI CAC-V-21B 2" V/2A/LO 7A 7A RMC 7B 7B 2" CAC-FCV-5B 1A1 CAC-V-800/14 CAC-V-800/18 1B1 MIX.
1" CAC-V-25A O CAC-V-800/41 DISABLED CAC-V-800/16 CAC-V-25B CAC-V-59B A 1"SW(85)-2 CONT. ON DWG. CODE GROUP D CAC-V-800/42 CAC-V-800/38 V/2B/LO CODE GROUP D 1" FROM RMS 10A C FROM RMS 3/4" CONT. ON DWG.
CAC-V-2A 2A SEE NOTE 15.
CAC-V-2B 3/4" N2 M524-1 (F/12) F.C. PI PT (G/12) FR FR 10B (G/3) PT PI F.C.
M524-2 (G/11)
CAC-V-28B CAC-ST-1A FE FIC EHO 6"x 4"RED O EHO FIC FE CAC-ST-1B 1A 1A 67A 1 1/2" TEST VENT 67B 1B 1B CAC-V-10B CAC-V-58B 4"CAC(2)-1-1 CAC-V-58A 5A 67A CAC-V-21A C 67B 5B 4"CAC(12)-1-1 EHO FR DRYWELL FR O EHO CODE GROUP D CAC-V-10A CODE GROUP D AL AL C B 2"
F D 67A1 F
2" 4"CAC(1)-1-1 (SEE NOTE 12 & 14) (SEE NOTE 12 & 14) 2" F 67BI F
CODE GROUP D CAC-V-1A 2" 2" 2" 2" CAC-V-1B OTHERS CONTR. 215 1/2" O.D. 1/2" O.D.
GROUP FC FC CAC-V-51A AL AL CAC-V-51B 2" F.C. F.C. T T F.C. F.C.
Q.C. II 67A INTERLOCK WITH INTERLOCK WITH 4"CAC(11)-1-1 67B CAS-V-718B H2 RECOMBINER H2 RECOMBINER CAS SEIS. II CAC-V-11B CAC-V-28A CAC-V-11A CAS CAC-V-52A CAC-V-52B PI SQRT SQRT CAC-V-56B PI 1"CAS-V-204B 1/2" CAC (60)-1-14 L CAC-V-56A PI BLOWER CONTAINER FS FT FE FE FT FS BLOWER CONTAINER PI L CODE PI 1" 17A CAC-FN-1A 4A 4B CAC-FN-1B 17B 1" 2A 6A 6A 6A 6B 6B 6B 2B 1" 1"CAS(5)-1 1/2"CAC(60)-1-6 28A CAC-V-27A CAC-V-27B CAC-V-55B 1 1/2"CAC(21)-1 RMS RMS 1 1/2"CAC(21)-1 CAC-V-55A RMS RMS ZONE (G/12)
RMS-10A RMS-10B SHUTDOWN 1" CAS 1/2" CAS 1" SHUTDOWN FT 4A FT AIR TEST CAS-V-718A 25 HP 25 HP 1"CAS-V-204A 3/4" 3/4" FI FS-6A-LOW FS-6B-LOW CONN. 1"CAS 1/2" OD SS 4A 4B FI CAC-V-306B CAC-V-305B (G/4)
FI CBC-V-306A CAC-V-305A M M 17A TS-7A-HI TUBING TS-7B-HI CONT. ON 3/4"CAC-V-316A C FI 1/2" OD SS 8B C 1/2" CAC(13)-1 17B DWG. M510-2 CAC-FCV-8A TS-5A-HI T AC O T O O T O T TS-5B-HI 8A AH DC DC AC TUBING AH 1"CAC-V-321A 1"CAC-V-321B (K/6) 3/4" 3/4" 1/2" TE TS-6A-HI TS-6B-HI TE 1/2" PI TO EHO MO MO EHO TO 1A-1 C C C C IB-1 2"CAC(12)-1 CAC-PCV-11A D TE CODE GROUP D CODE GROUP D TE CAC-FCV-8B CAC-PCV-11B 27A AH AH PI 2"CAC(2)-1 AH AH CAC-PCV-11A 7A 7B D H2 & N2 MIX 1/2"CAC(3)-1 6"x 4"RED 27B TS N.C. F.C. 6"x 4"RED N.C. TS CAC-V-316B BOTTLE TE TT TIC N.C./L.C. F.C. TIC TT TE 4"CAC(1)-1-2 N.C./L.C.
BY OTHERS AH 6A X-102 X-103 6B AH PI PI 4A 4A 4A 4B 4B 4B PI HYDROGEN &
TS TE TS CAC-V-4 CAC-V-13 4"CAC(11)-1-2 1/2"CAC(60)-1-13 TE TS AH AH 3A TE 1/2"CAC(60)-1-5 2 1/2"CAC-FCV-4A 2 1/2"CAC-FCV-4B TE 3B AH TS AH 28B H2 & N2 2A 2A 7A 2B 2B NITROGEN 6A 6B MIX BOTTLE TEST CONN.
TO CAC-V-15A 2"CAC(2)-1 CONT. AT FE CAC-V-800/31 CAC-V-800/11 CAC-V-800/9 CAC-V-800/7 FE CONT. AT 2"CAC(12)-1 CAC-V-15B 7B TO HYDROGEN BY OTHERS TS TR-1A TR-1B TS TEST CONN.
CAC-V-800/35 (LOCAL &
CODE GROUP D ZONE (C/14) 4A 3/4"CAC(55)-1-14 3/4"CAC(55)-1-16 3/4"CAC(55)-1-18 4B ZONE (C/2) CODE GROUP D E 3A MOISTURE 3/4"CAC(55)-1-13 (LOCAL & 3B E CAC-V-800/33 AIR TEST CONN MOISTURE 3/4"CAC(55)-1-17 TR REMOTE) SEPARATOR CAC-V-800/12 CAC-V-800/8 SEPARATOR REMOTE) TR CODE GROUP D 1"CAS(5)-1 CAC-V-800/10 3/4"CAC(55)-1-15 TE CAC-MS-1A 2" TE CODE GROUP D CAC-V-800/32 CAC-MS-1B CAC-V-800/36 1A1 CODE GROUP D 1B1 CONT. ON DWG. CAC-RV-63B CAC-RV-63A H 2"SW(84)-2 CAC-V-800/34 H
3A 2" PREHEATHER 3B M510-2 (K/6) PREHEATER AH AH 1" 2" CONT. ON DWG. 2"SW(86)-2 1" CAC-EHC-1B CONTR. OTHERS TR TE CAC-EHC-1A PS M524-1 (F/12) 3/4"CAC(55)-1-31 CONT. ON DWG.
PS TE TR 37kW CAC-V-13A CAC-V-13B 37kW CODE 1A 1A-7 68A CAC-V-64A M524-2 (H/11) CAC-V-64B 68B 1B-7 1B 215 Q.C. II GROUP D 2"CAC-(2)-1 2" SEIS. II AH AH LI LT LT LI O CAC-TCV-4A TE 1A 1A IB 1B TE C CAC-ST-2A TYP. FOR N2, H2 & N2 1B-2 1 1/2" 1A-2 MIX BOTTLES.
AFTERCOOLER CAC-V-62A CAC-V-62B AFTERCOOLER 1 1/2" TE EHO EHO TE LS CAC-V-14A CAC-EV-1A DISABLED CAC-EV-1B CAC-V-14B LS CODE GROUP C CODE GROUP C 1A-3 SEE NOTE 15. 1B-3 1A TE G 2"SW(83)-2 1B TE 2" CAC-RV-65A CONT. ON DWG. 2"SW(85)-2 CAC-ST-2B F.O. CAC-RV-65B 2" 1B-4 1A-4 RECOMBINER 2" RECOMBINER TE 3" CONT. ON DWG. 3" CAC-RD-1B CAC-RC-1A CAC-RD-1A M524-1 (F/12) CAC-RC-1B TE 1A-5 PT F.O.
CAC-V-61A M524-2 (G/11) G CAC-TCV-4B PT 1B-5 TS AH 68A 3" (SEE NOTE 12 & 14) (SEE NOTE 12 & 14) 3" 68B AH TS AH AH TE TE 5A CAC-V-29A EHO O CAC-V-61B O EHO CAC-V-29B 5B SQRT SQRT 5B 5A C C AH 2"CAC(2)-1 KEY LOCK KEY LOCK 2"CAC(12)-1 1/2"CAC(60)-1-8 TE 3A 3B TE 1/2"CAC(60)-1-7 1 1/2" 3/4"CAC(21)-1 3/4"CAC(21)-1 1/2"CAC(60)-1-15 1A-6 F.C. RMS RMS RMS RMS F.C. 1 1/2" 1B-6 SYSTEM SYSTEM D AH FT SUPPRESSION FT AH D
3/4"CAC-V-32A SHUTDOWN AH CODE GROUP D CAC-V-3A CAC-V-3B CODE GROUP D SHUTDOWN 3/4"CAC-V-32B A
CAC-V-57A 1"CAC(5)-1-1 CAC-V-57B CBC-V-303A CAC-V-304A 3A 3B CAC-V-303B CHAMBER CAC-V-304B 1"CAC(15)-1-1 CAC-V-322A 1 1/2"CAC(21)-1 CODE GROUP D T AC O T DC O O DC T O AC T CODE GROUP D 1 1/2"CAC(21)-1 1 1/2"CAC-V-322B EHO MO MO EHO C C C C 1" 3" 1 1/2" NOTE 12 K J 1" E E J K NOTE 12 A
NOTE 12 NOTE 12 1 1/2" 6"x 4"RED N.C. F.C.
4"CAC(2)-1-2 1"CAC-V-318A F.C. N.C./L.C. N.C./L.C. N.C. 1/2"CAC(60)-1-16 1"CAC-V-318B 4"CAC(12)-1-2 X-105 X-104 CAC-V-8 CAC-V-17 2 1/2"CAC-FCV-3B FE 2 1/2"CAC-FCV-3A FE 1 1/2" 1 1/2" 1 1/2" 1 1/2" CAC-HR-1A 3A CAC-V-800/25 CAC-V-800/1 CAC-V-800/3 3B CAC-HR-1B 3/4" 3/4" CAC-V-800/5 3"CAC(6)-1 1"CAC(5)-1 1"CAC(15)-1 3"CAC(16)-1 H2 RECOMBINER DIV. I 3/4"CAC(55)-1-23 H2 RECOMBINER DIV. II CAC-V-800/29 MO 3/4"CAC(55)-1-20 3/4"CAC(55)-1-22 3/4"CAC(55)-1-24 MO CAC-V-800/27 3/4"CAC(55)-1-19 2"CAC(21)-1 134A CAC-V-800/26 CAC-V-800/2 134B 2"CAC(21)-1 CAC-V-800/4 3/4"CAC(55)-1-21 CAC-V-800/6 SEE NOTE #8 (TYP)
CAC-V-800/28 CONT. FROM 2"CAC(21)-1-1 RHR RHR CAC-V-800/30 CONT. FROM 2"CAC(21)-1-2 ZONE E/5 (E/11) 2"RHR(28)-1-3 WATER SEAL 6"x 4"RED 2"RHR(28)-1-6 WATER SEAL 1/2" OD SS CONT. ON DWG. CONT. ON DWG. 1/2" OD SS LOOP LOOP TUBING CAC-V-65A M521-1 (E/14) M521-2 (E/6) CAC-V-65B TUBING C FURNISHED BY CONTR. NO. 71 FOR FURNISHED BY CONTR. NO. 71 FOR C INSTALLATION BY CONTR. NO. 215 3/4"CAC(55)-1-25 3/4"CAC(55)-1-26 INSTALLATION BY CONTR. NO. 215 RHR-1 CAC-1 CAC-1 RHR-1 CAC-V-66A CAC-V-67A CAC-V-67B CAC-V-66B 3"CAC(16)-1 FDR CONTAINMENT ATMOSPHERIC CONTROL SYSTEM B REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, B 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.
CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.
FSAR FIG.
COLUMBIA GENERATING STATION REV DATE DESCRIPTION DWN CHK APVD SIGNATURE DATE TITLE APPROVED A 57 04-11-02 REDRAWN PER 01486-016, 01554-004. 4WT/BLS KL SRP A
SCOTT PAYNE 04-11-02 FLOW DIAGRAM - H. & V.
58 7-23-04 CORRECTED INCORPORATION OF 1554-004. JFT KL DRJ CHECKED CONTAINMENT ATMOSPHERIC 59 8-11-05 REV PER 03539-288 (B-K/1-15) PL HL DRJ CONTROL SYSTEM K. LUCAS 03-07-02 REACTOR BLDG.
DRAWN B. L. STAFFORD 8-9-00 4WARDTECH 6-18-99 SCALE DWG NO. REV.
N.T.S. M554 59 PDS2-E1 R0 (9/94) SERVER84\00\G 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1