Drawing M523-3, Rev 1, Flow Diagram Reactor Water Clean-Up System Radwaste Bldg
ML053270116
Person / Time
Site: Columbia 
Issue date: 07/22/2004
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M523-3, Rev 1
Download: ML053270116 (1)


Text

2 1

3 15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 4

5 6

7 8

9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3

1 2

A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE CHECKED SCALE DRAWN DWG NO.

REV.

FLOW DIAGRAM REACTOR WATER CLEAN-UP SYSTEM RADWASTE BLDG.

M523-3 1

NONE L.W.CONLEY / N.THEISEN 01/08/01 B. L. STAFFORD 4-4-02 SCOTT PAYNE 5-31-02 SERVER84\\00\\DWG 2"MWR(59)-1 TO CHEM WASTE TANK M533-1 (G/6)

REACTOR BLDG.

RADWASTE BLDG.

MWR-V-653(D)

RWCU-V-719A RWCU-V-720A RWCU-DM-1A G33-Z001-A CLEAN-UP FILTER DEMINERALIZER N5 2"RWCU(20)-3 (AIR SUPPLY)

RWCU-V-616(V)

RWCU-V-452(V)

NOTE:

CLEAN-UP FILTER DEMINERALIZER RWCU-DM-1A AND PIPING, ETC., IS THE SAME AS RWCU-DM-1B, EXCEPT FOR SUFFIX LETTER "A".

3"RWCU(2)-3-1 (EFFLUENT) 3/4"RWCU(58)-3-2 SP 27A S

3"RWCU(27)-1 (RESIN BACKWASH) 2"MWR(67)-1 (CHEMICAL CLEANING OUT) 2"MWR(59)-1 (CHEMICAL WASTE) 4"CF(1)-1 (PRECOAT FEED) 3"RWCU(1)-3-1 (INFLUENT) 1"COND(62)-3 (TRAP BACKWASH CONDENSATE SUPPLY) 3"RWCU(51)-1 (BACKWASH VENT)

COND-V-447 RWCU-P-4 REACTOR BLDG.

RADWASTE BLDG.

3"RWCU(51)-1 (BACKWASH VENT) 4"CF(1)-1 (PRECOAT FEED)

RWCU-V-448 BEDPLATE DRAIN 1/2" PLUG G33-Z001-15 3/4"RWCU(50)-1 (CASING DRAIN)

RWCU-V-26 EDR DWG.

M540 G33-Z001-4 CLEAN-UP PRECOAT PUMP CF-V-735 CF-V-737 PX 4

CF RMS 6"CF(3)-1 CF-V-176 G33-Z001-57 3"

CF-V-640 G33-Z001-40 2"CF(6)-1 CF-V-314(D)

PI 73 CF CF-V-736 G33-Z001-73 4"CF(50)-1 (OVERFLOW)

AO 616 CF O

C CF-SPV-616 CF-V-616 4"CF(4)-1 CF-V-620 AO 620 CF CF-SPV-620 6"

CF-V-646 CF-1 MWR-1 G33-Z001-46 CF-V-32 6"

LS 75 RWCU AH 2"CF(50)-1 CF-V-647 AL G33-Z001-47 1"

3" 2"

1" 3"

3" 2"

CF-V-648 G33-Z001-48 1"CF(50)-1 4"CF(50)-1 1"CF(50)-1 CF-V-31 3"CF(50)-1 OVERFLOW EL. 472'-9" 1/4"CF(50)-1 RWCU-MX-5 G33-Z001-5 PRECOAT AGITATOR 1"

2"RWCU(51)-1 3"

3" G33-Z001-75 COND-V-249 G33-Z001-49 4"CF(2)-1 3"CF(7)-1 BATCH LEVEL RWCU-TK-2 G33-Z001-2 CLEAN-UP PRECOAT TANK RMS RWCU-EX-80 G33-Z001-80 DUST EVACUATOR CF-V-619 AO 619 CF CF-SPV-619 O

C G33-Z001-19 FG 81 CF G33-Z001-81 3"

1/2"CF(2)-1 3"RWCU(51)-1 RWCU-V-223 COND-V-221 COND-V-218 CF-F-68 G33-Z001-68 MILLIPORE FILTER CF-V-650 1/4" 1"COND(10)-1 COND-1 CF-1 AO 18 COND O

C COND-SPV-218 COND-SPV-221 AO 221 COND O

C COND-1 CF-1 3"COND(10)-1 G33-Z001-18 G33-Z001-21 FI 78 COND G33-Z001-78 FE 84 COND COND-V-876A COND-V-876B G33-Z001-76 COND-V-877 COND-V-258 G33-Z001-58 COND-PCV-264 G33-Z001-64 A

G33-Z001-84 FL. EL. 467'-0" FSAR FIG.

REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

PI 76 COND RMS (REF.)

2" 2"MWR(59)-1 2"

RMS PX 3

CF G33-Z001-20 O

C 4"

3"RWCU(51)-1 RADWASTE BLDG. CORRIDOR 1/2"COND(90)-1 DWG. M527-2 (F/7)

RWCU-TK-104A G11-D104A CLEAN-UP PHASE SEPARATOR N2 N3 N4 N5 N6 3"RWCU(51)-1 4"RWCU(27)-1 4"RWCU(18)-1 4"RWCU(15)-1 3"RWCU(11)-1 RWCU-V-428A AO 428A RWCU RWCU-SPV-428A FROM RWCU-TDS-23 ZONE (C/10)

AO 436A RWCU RWCU-SPV-436A G11-F428A G11-F436A 4"RWCU(15)-1 RWCU-V-429A RWCU-V-436A O

C G11-F429A RWCU-SPV-429A TO RWCU-LIS-113B ZONE (D/6)

COND-V-431 4"COND(18)-1 DWG. M527-2 (C/6)

G11-F431 4"RWCU(18)-1 RWCU-V-432 O

C AO 432 RWCU RWCU-SPV-432 COND-1 RWCU-1 SEE NOTE 2d SEE NOTE 2e FROM RWCU-TDS-23 (C/10)

TO RWCU-SPV-438A, B DWG. M536 (K/11)

RWCU-V-437A AO 437A RWCU G11-F437A RWCU-SPV-437A 3"RWCU(11)-1 3"RWCU(12)-1 RWCU-V-426A RWCU-V-430A 2"RWCU(50)-1 EDR O

C AO 426A RWCU G11-F426A RWCU-SPV-426A FROM RWCU

-LS-115A ZONE (D/13) 4"RWCU(14)-1 4"

N1 N7 6"

DWG.

M540 6"RWCU(50)-1 (OVERFLOW) 4"RWCU(14)-1 LS 115A RWCU AL G11-N115A TO RWCU-SPV-426A ZONE (C/10)

G11-N112A G11-N113A A

N8 4"

4" 4"

4" 3"

CAS-V-404A G11-R095A CAS-1 COND-1 CELL LIMIT 6"

N9 6" VENT SEE DWG. M549-2 (B/7)

L G11-N116A2 SPARED IN PLACE SEE NOTE 19 LE 62A RWCU 20"MH M1 6"

N10 1/2"CAS(10)-1S H

1S 1

G11-N116A1 G11-N062A G11-M023 FROM RWCU-PS-114 ZONE (B/12)

TO RWCU-SPV-432 ZONE (B/13)

TO RWCU-SPV-428A, 436A ZONE (C/13)

TO RWCU-SPV-428B, 436B ZONE (C/6)

TO PWR-SS-24B DWG. M536 (J/7)

TO PWR-SS-24A DWG. M536 (J/11)

G11-F421B RWCU-SPV-421 G11-F421A RWCU-V-421A F.C.

F.O.

RWCU-V-421B CF-1 RWCU-1 NOTE 2d NOTE 2e 4"RWCU(27)-1 4"RWCU(27)-1 4"RWCU(15)-1 FROM RWCU-LS-115B ZONE (D/6)

RWCU-V-426B RWCU-V-430B G11-F430B 2"RWCU(50)-1 3"RWCU(12)-1 DWG.

M540 PX 3

RWCU NOTE 16 PS 114 RWCU RWCU-V-737 L.C.

G11-N114 TO RWCU-TDS-23 ZONE (C/10)

RWCU-V-738 PX 4

RWCU RWCU-V-739 RWCU-P-28 RWCU-V-447 3"

2" G11-C028 CLEAN-UP SLUDGE DISCHARGE MIXING PUMP BEDPLATE DRAIN 1/2" PLUG 1/2"RWCU(82)-1 RWCU-V-444 RWCU-1 COND-1 SEE NOTE 2e SEE NOTE 2d 3/8" COND-V-461 1/2"COND(18)-1 DWG. M527-2 (C/6)

PI 3

RWCU RWCU-V-740 RWCU-V-427 G11-F427 RWCU-V-441 DWG.

M540 RWCU-V-602(V) 3"RWCU(13)-1 PX 5

RWCU RWCU-V-742 RWCU-V-443 3/4"RWCU(58)-1 AO 443 O

C RWCU-SPV-443 220 215 DEACTIVATED SEE NOTE 17 TO SP-45 FOR CONT.

SEE M607-3 (D/7)

(SEE NOTE 2d)

RWCU-V-437B AO 437B RWCU RWCU-SPV-437B RWCU-P-27 G11-C027 CLEAN-UP DECANT PUMP RWCU-V-446 3"

BEDPLATE DRAIN 1/2" PLUG 1/2"RWCU(19)-1S RWCU-ST-2 PI 5

RWCU-V-744 RWCU-V-433 G11-F443 RMS RWCU-V-434 G11-F434 EDR DWG.

M540 2"RWCU(19)-1 RWCU-V-435 SP 44 RWCU-V-745 AO 435 RWCU RWCU-SPV-435 G11-F435 FROM EDR-LS-146 DWG. M532 (B/11)

RWCU-FCV-331 RMC A

FCV F331 G11 RWCU-V-429B RWCU-V-436B G11-F436B RWCU-SPV-436B RWCU-V-428B RWCU-SPV-428B G11-F428B FROM RWCU-TDS-23 ZONE (C/9) 4"RWCU(18)-1 4"RWCU(27)-1 FROM RWCU-LIS-113A ZONE (D/14)

TO RWCU-SPV-426B ZONE (C/9)

G11-N112B G11-N115B G11-N113B RWCU-SPV-208B-1 A

A A

FULL OPEN SLOW DRAIN REWASH LOCATION IN CONTROL PANEL PO26 AH 2"RWCU(19)-1 DWG. M532 (E/14) 4"RWCU(18)-1 RMS POO1 LT 112A RWCU LIS 113A RWCU FIC 95A RWCU LS 116A1 RWCU LS 116A2 EDR RMS P001 AO 421A RWCU AO 421B RWCU O

C O

C LT 112B RWCU LS 115B RWCU LIS 113B RWCU 1/2"COND(90)-1 DWG. M527-2 (F/7)

AO 428B RWCU AO 436B RWCU TDS 23 RWCU EDR AO 429A RWCU RMS POO1 O

C RMS POO1 DWG.

M540 RMS POO1 AO 426B RWCU G11-F426B RWCU-SPV-426B RMS POO1 O

C G11-F430A EDR RMS P001 G11-F437B L.C.

L.C.

RMS POO1 4"RWCU(16)-1 4"RWCU(18)-1 1/2" RMS POO1 FDR RMS POO1 RMS POO1 1/2" 4"RWCU(15)-1 3"RWCU(11)-1 4"CF(50)-1(OVERFLOW)

O C

RMS POO1 O

C DWG.

M540 6"RWCU(50)-1 (OVERFLOW) 6" N7 RWCU-TK-104B 4"

N1 6"

N9 G11-D104B CLEAN-UP PHASE SEPARATOR N2 N3 N4 N5 N6 4"

4" 4"

4" 3"

N8 M1 N10 20"MH 1/2"CAS(10)-1S G11-N116B1 CAS-V-404B G11-R095B 6" VENT SEE DWG. M549-2 (B/7)

SPARED IN PLACE SEE NOTE 19 G11-N116B2 G11-N062B LE 62B RWCU LS 116B1 RWCU LS 116B2 A

FIC 95B RWCU 1S 1

CAS-1 COND-1 H

L 6"

G11-F429B RWCU-SPV-429B AL AH AO 429B RWCU RMS POO1 RMS POO1 O

C O

C O

C O

C RMS POO1 CELL LIMIT 3"RWCU(51)-1 SA-RV-265 G33-Z001-65 SA-F-69 SA-V-259 G33-Z001-59 PI 71 SA SA-V-703 SA-V-702 SA-V-22 G33-Z001-71 FI 79 SA G33-Z001

-85 G33-Z001

-79 SA-V-704 SA-V-23 1/2"SA(57)-1 1/2"SA(56)-1 SA-V-711 SA-PCV-10 PCV 10 SA-V-251 G33-Z001-51 3"SA(1)-1 SEE DWG.

M510-3 (D/5) 1" 3/4" 1 1/2" ED DWG.

M540 FE 85 SA 2"SA(1)-1 O

C AO 223 RWCU G33-Z001

-23 RWCU-SPV-223 G33-Z001

-16 (CHEMICAL WASTE)

FROM 2"MWR(59)-1 ZONE (F/3) 3/4" CF-RV-661 CF-V-303(V) 2" 2 1/2" 3"CF(54)-1 EDR DWG.

M540 G33-Z001-61 3"SA(1)-1 (AIR SUPPLY) 3"RWCU(1)-3-2 (INFLUENT)

RWCU-DM-1B G33-Z001-B CLEAN-UP FILTER DEMINERALIZER N3 N2 N1 N5 N4 1 1/2" 2"RWCU(51)-3-4 (2"RWCU(51)-3-3) 1/2"RWCU(51)-3-6 (1/2"RWCU(51)-3-5) 1/2" 1 1/4" 4"

RWCU-V-713B G33-Z001-77B 4"RWCU(1)-3-6 (3/4"RWCU(60)-3-7) 3/4"RWCU(60)-3-8 4"RWCU(1)-3-6 (4"RWCU(1)-3-7) 1 1/4"RWCU(20)-3-4 (1 1/4"RWCU(20)-3-3) 2"RWCU(20)-3-2 (2"RWCU(20)-3-1)

(AIR SUPPLY) 1 1/4"RWCU(20)-3-6 (1 1/4"RWCU(20)-3-5)

RWCU-V-617(V)

RWCU-V-453(V)

(3/4"RWCU(53)-3-9) 3/4"RWCU(53)-3-8 PI 77B RWCU TO ALARM IN MAIN CONTROL ROOM (3/4"RWCU(60)-3-17) 3/4"RWCU(60)-3-18 (3/4"RWCU(60)-3-5) 3/4"RWCU(60)-3-6 RWCU-V-711B RWCU-V-712B AH 1 1/2"RWCU(22)-3-2 4"RWCU(2)-3-2 (4"RWCU(2)-3-1)

DPIS 87B RWCU RMS 4"

(BACKWASH VENT)

RWCU-SPV-212B RWCU-V-229B RM RWCU-V-212B AO 212B RWCU (1/2"RWCU(51)-3-1) 1/2"RWCU(51)-3-2 RWCU-1 RWCU-3 RWCU-V-239B RM G33-Z001-39B RWCU-V-207B G33-Z001-7B AO 207B RWCU 1/2"RWCU(51)-1 RWCU-SPV-207B 2"RWCU(51)-1 G33-Z001

-83B 3"RWCU(51)-1 RMS RWCU-1 RWCU-3 RMS FG 83B RWCU O

C RWCU-RV-262B G33-Z001-62B EDR 1"RWCU(54)-1 RWCU-3 RWCU-1 NOTE 2d DWG.

M540 1"

1"RWCU(54)-3-2 (1"RWCU(54)-3-1)

(4"RWCU(1)-3-7)

AO 211B RWCU G33-Z001-11B RWCU-V-211B 4"RWCU(25)-3-2 (4"RWCU(25)-3-1)

RWCU-SPV-211B RWCU-3 CF-1 RWCU-V-238B G33-Z001-38B RM RWCU-SPV-238B A

AO 238B RWCU RMS RMS 4"CF(1)-1 4"CF(1)-1 (PRECOAT FEED)

TO RWCU-AO-231B ZONE (G/8)

AO 206B RWCU AO 232B RWCU RWCU-SPV-206B G33-Z001-6B RWCU-V-206B RWCU-V-232B RWCU-SPV-232B CHEMICAL CLEANING CONNECTION 3"RWCU(1)-3-4 (3"RWCU(1)-3-5)

O C

RMS G33-Z001-32B O

C RMS 3"

RWCU-V-233B G33-Z001-33B 3"RWCU(27)-3-4 (3"RWCU(27)-3-3)

MWR-1 RWCU-3 RWCU-V-291B G33-Z001-91B RM 1 1/2"RWCU(27)-3-6 (1 1/2"RWCU(27)-3-5) 2"MWR(67)-1 (CHEMICAL CLEANING OUT) 2"MWR(67)-1 (1 1/2"RWCU(22)-3-1)

RWCU-P-3B G33-Z001-3B CLEAN-UP HOLDING PUMP RWCU-V-422B RWCU-V-722B RWCU-V-721B 3/4"RWCU(60)-3-22 (3/4"RWCU(60)-3-21)

SEAL RWCU-V-449B BEDPLATE DRAIN RWCU-V-235B G33-Z001-35B 3/4"RWCU(50)-3 CASING DRAIN 1"RWCU(22)-3 RWCU-V-260B G33-Z001-60B RWCU-V-214B AO 214B RWCU RWCU-SPV-214B EDR 1 1/2" DWG.

M540 3/4"RWCU(50)-3-2 (3/4"RWCU(50)-3-1)

O C

RMS PI 2B 2"

PI 1B RWCU RM R

S 3"SA(1)-1 (AIR SUPPLY)

AO 234B RWCU RWCU-SPV-234B A

RWCU-V-234B RM O

C RMS 4"CF(2)-1 MWR-V-654(D) 4"RWCU(26)-3-2 (4"RWCU(26)-3-1) 2"RWCU(66)-3-2 (2"RWCU(66)-3-1)

RWCU-V-210B AO 210B RWCU RWCU-SPV-210B G33-Z001-10B CF-1 RWCU-3 RWCU-V-236B G33-Z001-36B MWR-1 RWCU-3 (PRECOAT RETURN &

BACKWASH SUPPLY) 2"MWR(66)-1 (CHEMICAL CLEANING IN)

G33-Z001-34B RMS O

C G33-Z001

-12B O

C G33-Z001

-14B 4"CF(1)-1 3"RWCU(1)-3-2 3"RWCU(1)-3-2 RM RWCU-V-208B RWCU-1 RWCU-3 NOTE 2e NOTE 2d RWCU-SPV-208B AO 208B RWCU G33-Z001

-8B 4"RWCU(27)-1 RMS 3"RWCU(51)-1 TO 2"MWR(59)-1 ZONE (G/14)

RWCU-V-230B RM G33-Z001-30B AO 213B RWCU G33-Z001-13B RWCU-SPV-213B RWCU-V-213B SA-1 RWCU-3 O

C 2"MWR(67)-1 SEE DWG.

M534 (E/1) 2"MWR(59)-1 3"RWCU(51)-1 RWCU-V-222 2"

SEE NOTE 2e RWCU-V-228 RWCU-SPV-222 G33-Z001

-22 RWCU-V-461(V)

RWCU-RV-267 2"

G33-Z001-67 RWCU-SPV-228 AO 222 RWCU RMS O

C SEE NOTE 2d AO 228 RWCU G33-Z001

-28 O

C RMS 3"RWCU(51)-1 (BACKWASH VENT)

SEE NOTE 2e SEE NOTE 2d 3"RWCU(1)-3-2 (INFLUENT)

SP 8

S RWCU-V-752 RWCU-V-751 3"RWCU(51)-1 (BACKWASH VENT) 4"RWCU(27)-1 (RESIN BACKWASH) 3"RWCU(51)-1 3"RWCU(51)-1 (BACKWASH VENT) 4"RWCU(27)-1 (RESIN BACKWASH) 2"MWR(67)-1 (CHEMICAL CLEANING OUT) 4"CF(1)-1 (PRECOAT FEED)

CF-RV-663 3"CF(54)-1 EDR G33-Z001-63 DWG.

M540 CF-V-309(V)

RWCU-V-714B RWCU-V-715B DPIS 88B RWCU G33-Z001

-88B 3"RWCU(2)-3 RWCU-V-241B RM G33-Z001-41B RESIN TRAP RWCU-V-243B G33-Z001-43B 1"RWCU(24)-3-2 (1"RWCU(24)-3-1) 3/4"RWCU(60)-3-16 (3/4"RWCU(60)-3-15)

AH (3/4"RWCU(60)-3-13) 3/4"RWCU(60)-3-14 PI 72B RWCU RWCU-V-716B 3/4"RWCU(60)-3-20 (3/4"RWCU(60)-3-19) 4"RWCU(2)-3-2 G33-Z001-70B RWCU-V-242B RM G33-Z001-42B RWCU-1 RWCU-3 SEE NOTE 2e SEE NOTE 2d RM 1"RWCU(24)-1 RWCU-V-245B G33-Z001-45B 1"RWCU(23)-3-2 RM (1"RWCU(23)-3-1)

RWCU-V-244B RM G33-Z001-44B RWCU-3 COND-1 G33-Z001

-72B 3"RWCU(2)-3-2 (3"RWCU(2)-3-1) 3/4"RWCU(60)-3-12 (3/4"RWCU(60)-3-11)

FE 86B RWCU G33-Z001

-86B RWCU-V-717B 3/4"RWCU(60)-3-10 (3/4"RWCU(60)-3-9)

RWCU-V-718B FT 89B P/I 90B RWCU G33-Z001

-90B FS 14B RWCU FQI 89B RWCU FC 89B RWCU I/P 89B RWCU RWCU-SPV-266B RWCU-FCV-266B O

C FCV 266B RWCU G33-Z001

-66B RWCU-V-231B O

C AO 231B RWCU RWCU-SPV-231B G33-Z001

-31B SP 27B S

RWCU-V-719B RWCU-V-720B 3/4"RWCU(58)-3-1 (3/4"RWCU(58)-3-2)

CHEMICAL CLEAN CONN.

3"RWCU(2)-3-4 (3"RWCU(2)-3-3)

PS 94B RWCU G33-Z001-94B FS 74B RWCU AL 2"MWR(66)-1 (CHEMICAL CLEANING IN) 2"MWR(66)-1 SEE DWG. M534 (E/1)

(PRECOAT RETURN &

BACKWASH SUPPLY) 4"CF(2)-1 2"

A TO RWCU-DPIS-87B ZONE (J/5)

TO RWCU-P-3B ZONE (G/5)

TO RWCU-FS-14B ZONE (J/9)

TO RWCU-SPV

-266B ZONE (G/9)

FROM RWCU-AO-232B ZONE (H/3)

SEE DWG.

M527-2 (H/8) 3"RWCU(1)-3-2 (INFLUENT) 3"RWCU(2)-3-2 (EFFLUENT) 4"RWCU(2)-3-1 (EFFLUENT) 4"RWCU(1)-3-1 (INFLUENT) 3/4"RWCU(58)-3-3 RMS COND-V-1080 NOTES:

FOR NOTES SEE M523-1.

3"RWCU(11)-1 1"RWCU(13)-1 (PRECOAT RETURN &

BACKWASH SUPPLY) 4"RWCU(26)-3-2 (4"RWCU(26)-3-1) 4"RWCU(18)-1 3/4"RWCU(50)-1 3"RWCU(54)-1 1/2" O

C 3"RWCU(11)-1 RM 3"SA(1)-1 (AIR SUPPLY) 3"SA(1)-1 3"

3" 1 1/2" 1 1/2"CF(5)-1 2"

2 1/2" 4"

6" G33-Z001-69 4"

4"RWCU(27)-1 (RESIN BACKWASH)

G11-F432 L.C.

3/4"RWCU(50)-1 1 1/2"COND(62)-1 (TRAP BACKWASH CONDENSATE SUPPLY) 4"RWCU(18)-1 DWG. M527-2 (H/8)

COND. SUPPLY 0

5-31-02 NEW DRAWING PER 01553-010, 01422-016, 01422-017, 01459-007.

LWC/NT BLS SRP 1"

4"CF(50)-1 (OVERFLOW) 3"RWCU(51)-1 3"

3" (3"RWCU(1)-3-1)

RWCU-RST-70B G33-Z001-87B TO 4"RWCU(1)-3-1 (INFLUENT)

DWG. M523-1 (J/4)

TO 4"RWCU(2)-3-1 (EFFLUENT)

DWG. M523-1 (G/4) 2"MWR(59)-1 TO CHEM. WASTE TANK DWG. M533-1 (G/8)

AIR FILTER (REF.)

1"RWCU(13)-1 SEE DWG. M536 (J/11) 4"RWCU(15)-1 RMS O

C RWCU-SPV-208B-2 A

RMS RMS RMS RMS RMS 1 1/4" 1 1/4" FI 605B RWCU C

G33-R605 SEE DWG M527-2 (H/8) 2"RWCU(21)-3-2 (2"RWCU(21)-3-1)

(1 1/2"RWCU(22)-3-1) 1 1/2"RWCU(22)-3-2 3/4"RWCU(60)-3-24 (3/4"RWCU(60)-3-23) 4"RWCU(14)-1 CF-V-615 1

7-22-04 REV PER 02963-005 (G/12).

H.AL HL SRP