TO COND-HX-1A 10"SS(5)-1 TO COND-HX-9 M506 (J/9)
M506 (J/9)
SS 3 - VALVE 3 - VALVE MANIFOLD MANIFOLD 5"
MD-1 MD-2 MD-1 MD-2 MD-1 MD-2 FROM MS-HX-1A FROM MS-HX-1B M502-1 (J/10)
M502-1 (J/6)
FROM MS-HX-1A FROM MS-HX-1B M502-1 (H/10)
M502-1 (H/6)
FROM MS-HX-1A FROM MS-HX-1B M502-1 (G/10)
M502-1 (G/6)
TRAP STA #33A SEE M502-2 (G/2)
TRAP STA #33B SEE M502-2 (G/2) 2 1/2" SS(8)-1 3" SS(9)-1 8" SS(9)-1 SS SS 8" SS(8)-1 1 1/2" SS(9)-1 1 1/2" 1" SS(50)-2 CONT ON DWG M506 (H/9)
TO CONDENSER 1" SS(50)-1 CONTRACT 215 WECO CONTRACT 215 WECO TO CONDENSER M506 (J/11)
TO CONDENSER M506 (H/9) 4" SS(6)-1 SS SEE M502-2 (E/3)
H/L SS H/L SS SS SS SS SEE DET 1 SEE DET 1 TO CONDENSER TO CONDENSER HP TURBINE TRAP STA #23 SEE M502-2 (E/3) 4" SS(9)-1 8" SS(9)-1 1" SS(50)-2 TO ATMOSPHERE ROOF 18" SS(4)-1 3/4" SS (50)-1 10" 14" SS(4)-1 3/4" SS(50)-1 CONT M506 (C/14)
T SS-T-6B 3/4" SS(50)-1 8"
8" SS(1)-2 6" SS(4)-1 STEAM EVAPORATOR SS-EV-1B AS-2 SS-2 CONT'D 8" AS(1)-2 10" T
SS-T-6A 8" SS(1)-2 8"
M513 (J/12) 1" SS(50)-2 8" SS(1)-2 14" SS(4)-1 1" SS(2)-2 6" SS(4)-1 STEAM EVAPORATOR SS-EV-1A LEFT STEAM CHEST SEE DWG M502-1 (F/9)
FOR DETAILS AIR FLOW TURBINE SHAFT SEAL STEAM SUPPLY 3-5 PSIG GLAND EXHAUSTER NEGATIVE 10-15" H O 2
DETAIL 5 FEED WATER TURBINE HP GLAND SEALING STEAM ARRANGEMENT AIR FLOW STEAM FLOW TO CONDENSER GLAND EXHAUSTER NEGATIVE 10-15" H O 2
SEAL STEAM SUPPLY (30-60 PSIA)
CONTAMINATED STEAM LEAKOFF TO CONDENSER DETAIL 6 FEED WATER DRIVE TURBINE VALVE STEM SEALING ARRANGEMENT 2
GLAND EXHAUSTER NEGATIVE 10-15" H O SEAL STEAM SUPPLY (150-200 PSI)
AIR FLOW DETAIL 4 REHEAT VALVE STEM SEALING ARRANGEMENT 2
GLAND EXHAUSTER NEGATIVE 10-15" H O SEAL STEAM SUPPLY (150-200 PSI)
GLAND EXHAUSTER NEGATIVE 10-15" H O 2
SEAL STEAM SUPPLY (30-60 PSIA)
CONTAMINATED STEAM LEAKOFF
- 2 FW HEATER DETAIL 3 VALVE STEM SEALING STEAM ARRANGEMENT TURBINE SHAFT GLAND EXHAUSTER NEGATIVE 10-15" H O 2
DETAIL 1 LP TURBINE GLAND SEALING STEAM ARRANGEMENT AIR FLOW STEAM FLOW SEAL STEAM SUPPLY 1-3 PSIG SEE DET 2 SEE DET 2 TURBINE SHAFT GLAND SPILLOVER 16 PSIA GLAND EXHAUSTER NEGATIVE 10-15" H O 2
DETAIL 2 HP TURBINE GLAND SEALING STEAM ARRANGEMENT AIR FLOW STEAM FLOW SEAL STEAM SUPPLY 20 PSI ABOVE HP TURBINE EXHAUST SS-ST-4F SEE DWG M511 (F/10) 4" SS(3)-1 1 1/2" 1 1/2" 1 1/2" 1 1/2" H/L SS SS SS SEE DET 1 1 1/2" 1 1/2" SS-ST-4E 2"
1 1/2" TO CONDENSER TO CONDENSER (L-3IV)
(L-3RV)
(R-3RV)
(R-3IV)
SEE DET 4 (TYP) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" SS-ST-4D 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" SS-ST-4C 2"
(L-2RV)
(R-2RV)
(R-2IV) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 12" SS-ST-4B 1 1/2" 1 1/2" 1 1/2" 1 1/2" SS-ST-2A SS-ST-3 6" SS(9)-1 SS-ST-2B SS(5)-1 SS SS 6"
1" SS(7)-2 6" SS(8)-1 6" SS(3)-1 SS 5"
GLAND STEAM CONDENSER COND-HX-7 TRAP STA #22 (M502 SH 1)
TRAP STA #32 SEE M502-2 (G/3)
SEE M502-2 (E/3) 1 1/2" SS(2)-2 3" SS(2)-2 1 1/2" SS(2)-2 4" SS(2)-2 TRAP STA #21 RFW-DT-1B 2"
SS 6" SS(2)-1 16" CO(54)-1 DWG M513 (J/6) 3/4" SS(50)-1 ED 2 1/2" 4" SS(2)-1 RFW PUMP PIT HP STOP VALVE LP STOP VALVE LO 3/4" 1/2" HP STOP VALVE LP STOP VALVE (M502 SH 1) 4" SS(3)-1 TRAP STA #31 SEE M502-2 (G/3)
TO ROOF VENT SEE M502-2 (E/3) 3" SS(2)-2 1 1/2" SS(2)-2 SS M503-1 (K-10)
M503-1 (G-10)
M503-1 (E-10)
TO FW HTR 2C 6" SS(10)-1 TO FW HTR 2B 6" SS(10)-1 TO FW HTR 2A 6" SS(10)-1 TRAP STA #26 M502-2 (E/3) 1 1/2" SS(7)-2 30" MS(4)-2 TO MAIN CONDENSER M502-1 (D/2)
(BPV-4)
(BPV-3)
(BPV-2)
(BPV-1)
FROM REACTOR PRIMARY STEAM SYSTEM M502 SH 1 (D/2-4) 4" 5"
8" 12" 2"
2 1/2" SS(1)-2 4" SS(1)-2 6" SS(1)-2 TO CONDENSER DWG M506 (F/11) 3" SS(2)-2 1 1/2" SS(2)-2 4" SS(2)-2 TRAP STA #20 RFW-DT-1A 2"
2" 4" SS(2)-1 RFW PUMP PIT LO 3/4" 1/2" TO CONDENSER CONT ON DWG M506 (F/11)
RIGHT STEAM CHEST SEE M502-1 (F/6)
FOR DETAILS 10" SS(10)-1 1 1/2" SS (7)-2 1 1/2" SS (7)-2 LP TURBINE 3 (C)
LP TURBINE 2 (B)
H/L SS SS 1 1/2" 1 1/2" SS-ST-4A 2"
1 1/2" SS SS SS SS SS SS SS 4"
6"SS(5)-1 FROM BS-PT-3A3 DWG M502-1 (E/6)
H/L H/L SS SS SS 1 1/2" 1 1/2" TO CONDENSER DWG M506 (F/11)
FROM BS-PT-3B3 DWG M502-1 (G/9)
SEE DET 1 SEE DET 1 SEE DET 1 SEE DET 4 (TYP)
SEE DET 4 (TYP)
SEE DET 3 (TYP)
SEE DET 6 (TYP)
SEE DET 5 SEE DET 1 SEE DET 5 SEE DET 1 SEE DET 6 (TYP)
H/L TO CONDENSER SS SS SS SS SS MS-V-165A MS-V-166A (L-1IV)
(L-1RV)
(R-1RV) 3" SS(9)-1 SS(1)-2 (R-1IV) 4" SS(9)-1 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" MS-V-163A LP TURBINE 1 (A)
MS-V-164A NOTE:
- 1. FOR NOTES AND LEGEND, SEE M502 SH 1.
6" SS(10)-1 6" SS(10)-1 FLOW DIAGRAM MAIN & EXHAUST STEAM SYSTEM TURBINE GENERATOR BUILDING A
B C
D E
F G
H J
K A
B C
D E
F G
H J
K 4
5 7
6 8
9 10 11 12 13 14 15 2
3 1
4 5
7 6
8 9
10 11 12 13 14 15 2
3 REV DATE DWN CHK APVD DESCRIPTION D JACOBSEN 5-7-86 SEE DET 3 (TYP)
SEE DET 3 (TYP)
N/A 16 3
3 M502 TITLE DATE SIGNED APPROVED SR PAYNE JR MILLER JE PARKER JE PARKER ENGINEER 3-11-87 3-11-87 3-11-87 3-11-87 DESIGN SUPV CHECKED DRAWN SCALE REV.
SHEET OF DRAWING #
SERVER84\\00\\dwg SS-PCV-4A SS-V-50A SS-V-48A PC 4A A
PI 5A RO 4B SS RO 3B SS 5A PS A
C A0265 5A PT PTD 5A PS 4B A
PT 4B PI 4B1 SS-PCV-2B SS-V-44B SS-V-42B SS-V-43B SS-V-82 SS-PCV-2A SS-V-44A SS-V-42A SS-V-43A C
A0263 C
A0264 4A PS A
4A PT 4A1 PI SS-PCV-3 SS-V-45 SS-V-47 SS-V-86 SS-V-85 SS-V-717A SS-V-717B DPT 2B SS-V-750B SS-V-752B SS-V-751B 2A DPT SS-V-750A SS-V-752A SS-V-751A SS-V-718A SS-PCV-4B SS-V-50B SS-V-48B PC 4B PI 5B SS C
A0266 5B PS A
SS-V-718B RO 5C SS MS-V-GV/2 MS-V-TV/2 SS-V-605(D)
SS-V-602(V)
RMS BD A MO SS-V-7A PI 1A MS-V-GV/4 MS-V-TV/4 MS-V-GV/1 MS-V-TV/1 SS-V-617(V)
SS-V-83 A
MS-V-GV/3 MS-V-TV/3 MS-V-160C MS-V-160D SS-PCV-126 SS-V-23 SS-V-24 SS-V-25 SS-V-11C SS-V-11B SS-V-11A SS-RV-12A MO SS-V-6A SS-PCV-1A SS-V-702A RMS BD A MO PI 4A SS SS-V-724A PX 1A O
C O
C O
C BS-V-60A MS-V-172A SS-V-714A SS-V-27A C
NOTE 10 PS 1A SS PT 1A SS AL HPCV LPCV SS-V-603(D)
SS-V-606(V)
SS-V-619 RMS BD A MO SS-V-7B PI 1B SS-RV-12B MO SS-V-6B SS-PCV-1B SS-V-702B RMS BD A MO PI 4B SS SS-V-724B PX 1B O
C O
C O
C BS-V-60B MS-V-172B SS-V-714B PI 3G/1B SS C
NOTE 10 PS 1B SS PT 1B SS AL HPCV LPCV SS-V-27B SS-V-608(V)
A0029 PI 3
PTD 3
SS SS-V-609(V)
SS-V-610(V)
PI 39 SS RMS BD B MO RMS BD B MO C
A0156 PI 8
PT 8
SS-V-721 SS-V-46 PC 2B PC 2A SS-V-49A SS-V-49B SS-PCV-4C SS-V-50C SS-V-48C PC 4C PI 6A SS 6A PS A
C A0267 6A PT PTD 6A SS-V-719A SS-PCV-4D SS-V-50D SS-V-48D SS-V-49C SS-V-49D SS-PCV-4E SS-V-50E SS-V-48E RO 3D SS RO 4D SS RO 5E SS RO 5D SS RO 4E SS SS-PCV-4F SS-V-50F SS-V-48F PC 4F PI 7B SS C
A0270 7B PS A
PT 7B SS-V-720B SS-V-49E SS-V-64 SS-V-49F RMS BD B MO SS-V-4 (TH)
RMS BD B MO SS-V-31 RMS BD B MO SS-V-1A SS-RV-9A SS-V-65A SS-V-10B SS-V-10A RMS BD B MO SS-V-5 RMS BD B MO SS-V-1B (TH)
SS-RV-9B SS-V-65B O
C O
C O
C O
C MO O
C RMS BD B SS-V-2 SS-V-3 O
C SS-V-601(V)
A RO 4A SS RO 5A SS RO 5B SS A
A0268 6B PS A
6B PT PTD 6B SS-V-719B PC 4E PI 7A SS 7A PS A
C A0269 SS-V-720A A
A RO 4F SS RO 5F SS SS-V-704A SS-V-703A SS-V-703B SS-V-704B SS-V-725 SS-RV-13 SS-V-723 A
PI 126 SS PC 126 SS SS-V-63 (V)
RO 1
SS PC 3
SS A
SS-V-84 A
MS-V-160A RO 2
SS MS-V-160B SS-V-701 RO 15 SS RO 14 SS RO 3E SS RO 3F SS RO 7B SS RO 6B SS RO 7A SS RO 6A SS RO 3A SS RO 3C SS PI 3G/1A SS SS-V-722 PT 2
C A0028 PTD 2
SS SS-V-8A SS-V-8B PI 1A1 SS PI 1B1 SS FI 1
SS SS-V-38 SS-V-41 SS-V-40 SS-PCV-39 A
39 PC SS 9
12-4-97 REVISED PER 95-09-010-0003 (B/14).
HL KL DLE 10 3-30-98 REVISED PER 97-11-003-0002 (B/14).
HL KL DLE 11 4-13-98 CORRECTED INCORPORATION OF 97-11-003-0002 (B/14).
HL KL DLE (TH) 12 4-10-00 REVISED PER 96-12-001-0009 (A/13).
KL HL DRJ MS-V-166B MS-V-165B MS-V-164B MS-V-163B MS-V-166C MS-V-165C MS-V-164C MS-V-163C 13 4-6-01 REVISED PER 00786-003 (D,G,J/8-10).
KL BLS SRP COLUMBIA GENERATING STATION FSAR FIG.
REV DATE DESCRIPTION DWN CHK APVD 14 6-28-01 REV PER 98-0117-0A-319 (F/10), 98-0117-0A-320 (H/10).
BLS KL SRP PT 5B SS PT 7A SS 15 10/24/02 REV PER 00812-003 (D-H/9-10)
MF HL SRP 16 11-14-03 REV PER 02502-005 (C-D/6-7), 02702-006 (H/14)