Drawing M523-1, Rev 104, Flow Diagram Reactor Water Clean-Up System Reactor Bldg
ML053270113
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 10/14/2005
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M523-1, Rev 104
Download: ML053270113 (1)


Text

RPV INVERT ELEV 521'- 0 1/4" REACTOR VESSEL 2

1 3

15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 4

5 6

7 8

9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3

1 2

A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE CHECKED SCALE DRAWN DWG NO.

REV.

FLOW DIAGRAM REACTOR WATER CLEAN-UP SYSTEM REACTOR BLDG.

M523-1 104 NTS L.W.CONLEY / N.THEISEN 01-08-01 B. L. STAFFORD 4-4-02 SCOTT PAYNE 5-31-02 SERVER84\\00\\DWG REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

FSAR FIG.

101 5-31-02 REDRAWN AND REVISED PER 01485-011, 01553-008. ADDED SHEET 3.

LWC/NT BLS SRP NOTES:

LEGEND:

1. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE EXCEPT AS NOTED.
2. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.
3. ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.

REACTOR BLDG.

RADWASTE BLDG.

RADWASTE BLDG.

REACTOR BLDG.

1. ALL ITEMS MARKED
  • ARE FURNISHED WITH ASSOCIATED EQUIPMENT.
2. PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DRAWING SHALL BE CLASSIFIED AS FOLLOWS, EXCEPT AS STATED IN NOTE 10:

(BREAK POINTS INDICATED ON FLOW DIAGRAM).

a. PIPING AND VALVES OUT THROUGH THE OUTERMOST ISOLATION VALVES, EXCEPT INSTRUMENT PIPING AS NOTED:

SEISMIC CATEGORY: I QUALITY CLASS: I CODE GROUP: A

b. INSTRUMENT PIPING, AND VALVES CONNECTED TO RCPB, ISOLATED BY A FLOW LIMITING VALVE, AND PROVIDING A SIGNAL TO THE LEAK DETECTION SYSTEM:

SEISMIC CATEGORY: I QUALITY CLASS: I CODE GROUP: B

c. INSTRUMENT PIPING, VALVES, AND FLOW ORIFICE CONNECTED TO THE RWCU SYSTEM THAT PROVIDE A SIGNAL TO THE LEAK DETECTION SYSTEM:

SEISMIC CATEGORY: I QUALITY CLASS: I CODE GROUP: C

d. PIPING, VALVES, AND ASSOCIATED COMPONENTS BEYOND OUTERMOST ISOLATION VALVES (INCLUDING IN THE CF, COND, CPR, MWR, AND SA SYSTEMS), EXCEPT AS STATED IN NOTE 2e & 2f.

SEISMIC CATEGORY: II Å QUALITY CLASS: II CODE GROUP: D *

e. PIPING, VALVES, AND ASSOCIATED COMPONENTS IN RADWASTE BUILDING: (AS INDICATED BY BREAKPOINTS)

SEISMIC CATEGORY: II QUALITY CLASS: II +

CODE GROUP: D +

f. PIPING AND ASSOCIATED COMPONENTS BEYOND OUTERMOST ISOLATION VALVE (RWCU-V-4) TO, AND INCLUDING VALVES RWCU-V-5A & 5B:

(AS INDICATED BY BREAKPOINTS)

SEISMIC CATEGORY: II Å QUALITY CLASS: II CODE GROUP: C

Å HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I IN SEISMIC AREA, SUCH AS THE REACTOR BUILDING AND THE RADWASTE BUILDING CORRIDOR.

  • PRESSURE VESSELS AND ASSOCIATED COMPONENTS WERE INSTALLED AS ASME III/CLASS 3. IF REPLACED, ASME SECTION VIII, DIVISION 1 NOW APPLIES.

+ SEE NOTE 12, WNP-2 SPECIFICATION, SECTION 15B.1, TABLE 2 NOTES.

g. PIPING, VALVES, AND ASSOC. COMPONENTS REFERRING TO THIS NOTE:

SEISMIC CATEGORY: I QUALITY CLASS: I CODE GROUP: C

Å HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.

EXCEPT AS NOTED ON M619 INSTRUMENT CONNECTION DIAGRAMS.

(+SEE NOTE 12, CONTRACT 215, SECTION 15B, TABLE 2 NOTES.)

3. ALL PIPING SYSTEMS INDENTIFIED BY THIS PREFIX "PI" SHALL BE SUPPLIED AND INSTALLED BY CONTRACT 220.
4. (DELETED)
5. ALL INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.
6. (DELETED)
7. EXCESS FLOW CHECK VALVES SHALL BE TAGGED AS FOLLOWS:

PI-EFC-X (PENETRATION NO.)

8. CONTAINMENT INSTRUMENTATION ROOT VALVES SHALL BE TAGGED AS FOLLOWS: PI-V-X (PENETRATION).
9. (DELETED)
10. ALL PIPING DOWN STREAM OF THE LAST ISOLATION VALVE, AND OPEN TO THE ATMOSPHERE WITH THE SUBSYSTEM DESIGNATION "SYSTEM" (50) THRU (59), SHALL BE CLASSIFIED AS CODE GROUP "D", WITH QUALITY CLASS AND SEISMIC CATEGORY PROVIDED BY THE APPLICABLE NOTES IN THIS DRAWING. EXCEPT WHERE THE APPLICABLE NOTES CALL FOR QUALITY CLASS II+, PIPING SHALL BE QUALITY CLASS II.
11. VALVES RWCU-V-210A&B ARE TO BE INSTALLED WITH THEIR FLOW ARROWS POINTED IN THE DIRECTION OF VALVES RWCU-V-234A&B.
12. LINE NUMBERS IN PARENTHESES DENOTE RWCU-DM-1A SYSTEM INDENTIFICATION.
13. NO UNIQUE LINE NUMBERS GIVEN FOR RWCU(ALL)-1 PIPING AS THESE ARE RADWASTE LINES.
14. ALL INSTRUMENT LINES ARE DESIGNATED BY CODE AND LINE NUMBER.
a. EXAMPLE: LINES ORIGINATING OUTSIDE CONTAINMENT.

1/2"PI(1)-ST - (H22-P021)-A6 CODE DESIGNATION LINE NUMBER

b. EXAMPLE: LINES ORIGINATING INSIDE CONTAINMENT.

1/2"PI(1)-4S - X106 CODE DESIGNATION LINE NUMBER

c. EXAMPLE: CONTINUATION OF THE ABOVE LINE OUTSIDE CONTAINMENT IS DESIGNATED AS FOLLOWS, WITH LINE NUMBERS NOT SHOWN.

1/2"PI(1)-ST-X106 - (H22-P021)

CODE DESIGNATION LINE NUMBER

15. CODE BREAK DEFINITIONS FOR THERMOWELLS ARE SHOWN ON M610, "INSTALLATION OF THERMOWELLS AND SAMPLE PROBES."
16. RWCU-PS-114 CONTACTS JUMPERED CLOSED TO INDICATE NORMAL PUMP SUCTION PRESSURE.
17. VALVES RWCU-V-443 AND RWCU-SPV-443 HAVE BEEN DEACTIVATED TO PREVENT INADVERTENT RESIN SPILLS.
18. FOR SAMPLE FUNCTION & INSTRUMENTATION ASSOCIATED WITH THE SAMPLE POINTS SEE DWG. SERIES M607 STEAM & LIQUID SAMPLING FLOW DIAGRAMS AND DWG. SERIES 60A-00 SAMPLE RACKS DETAILS &

FLOW DIAGRAMS.

NOTES CONT. (K/4)

NOTES:

19. SLUDGE LEVEL RWCU-LE-62A AND 62B, RWCU-LS-116A1/A2 AND RWCU-LS-116B1/B2 ARE SPARED IN PLACE. THEY HAVE BEEN HISTORICALLY UNRELIABLE. SLUDGE LEVEL IS PRESENTLY MORE RELIABLY DETERMINED AND CONTROLLED BY USING THE PPM (SOLID WASTE PROCESSING SYSTEM).

RWCU-P-1A RWCU-P-1B CLEAN-UP RECIRCULATION PUMPS (SEE M523-2)

RWCU-V-109 RWCU-V-110 RRC-P-1A 6"RWCU(8)-1 CONT. ON M532 (B/15) 3/4"RWCU(55)-4-2 6"RWCU(8)-1 RWCU-V-35 RWCU-3 RWCU-1 MO 35 RWCU O

C RMS 6"RWCU(5)-3-2 RWCU-RV-36 G33-F036 4"CPR(34)-1 CPR-1 RWCU-1 3"RWCU(8)-1 RWCU-V-34 RWCU-3 CPR-1 MO 34 G33-FO34 RMS O

C RWCU 6"CPR(28)-1 CONT. ON M526-1 (A/14)

RWCU-V-736 PS 14 G33-N014 RWCU RWCU-V-911(V) 3/4"RWCU(60)-3-25 6"RWCU(5)-3-1 TO LIMIT SW RWCU-V-1 (E/13)

RWCU-V-4 (D/15) 3/4"RWCU(3)-4S CONT. TO ZONE (H/5) 6"RWCU(3)-4-1(CL.3)

THERMAL SLEEVE 6"RWCU(3)-4-1(CL.3)

RWCU-V-704 PI 9

RWCU G33-R009 RWCU-V-901(V)

SEE NOTE 2d SEE NOTE 2f RWCU-V-4 SEE NOTE 2f SEE NOTE 2a MO 4

G33-FOO4 RMS RWCU D.C.

O C

ISOL. A,J,E,Y,W SIGNAL LS TO RWCU-FCV-33 T

RWCU-V-607(D)

RWCU-V-608(D)

RWCU-V-612(V)

RWCU-V-611(V) 3/4"RWCU(53)-4-1 TDS 621A E31-R621A FI 620 E31-R620 FS 605A E31-N605A SUM 604 E31-K604 TDS 621B E31-R621B FS 605B E31-N605B A

T T

A LD LD LD LD LD LD FROM: SQRT-602 ZONE (G/15)

FROM: SQRT-603 ZONE (H/9)

FROM: SQRT-605 ZONE (C/7) 6"x4" RED.

RWCU-FCV-33 RWCU-V-31 6"x4" RED.

MO 31 G33-F031 RMS O

C RWCU RO 1

G33-D001 RWCU RWCU-3 RWCU-3S RWCU-3 AHL 4"RWCU(60)-3-28 4"

4"RWCU(5)-3-1 RWCU-V-733 PS 13 RWCU RWCU-V-910(V) 4"RWCU(60)-3-29 6"RWCU(5)-3-1 RWCU-SPV-33 E/P 1

G33-KOO1 RMC 606 G33-R606 RWCU RWCU G33-F033 RWCU-V-32 RWCU-V-471H RWCU-V-471L RWCU-V-472H RWCU-V-472L FE 11 G33-N011 RWCU 1/2"PI(1)-ST-RWCU-FT-15(HIGH) 1/2"RWCU(60)-3-27 1/2"RWCU(60)-3-26 1/2"PI(1)-ST-RWCU-FT-15(LOW)

FT 16 E31-N015 RWCU 1/2"PI(1)-ST-RWCU-FT-16(HIGH) 1/2"PI(1)-ST-RWCU-FT-16(LOW)

RWCU-V-475 RWCU-V-476 FT 15 E31-N015 RWCU RWCU-V-770 RWCU-V-771 FS 16 LD AH SQRT 605 RWCU FI 602 G33-P602 RWCU FS 15 LD AH SQRT 16 RWCU FI 16 RWCU TO RWCU-V-1 (F/14)

ISOLATION SIGNAL "J" TO LEAK DETECTION SYSTEM LD-SUM-604 ZONE (D/11)

TO RWCU-V-4 (E/15)

ISOLATION SIGNAL "J" SEE NOTE 2c 6"RWCU(5)-3-1 4"RWCU(2)-3-1 (EFFLUENT)

CONT. ON M523-3 (F/15) 4"RWCU(1)-3-1 (INFLUENT)

CONT. ON M523-3 (E/15)

RWCU-V-1 MO 1

G33-F001 RWCU FI RMS O

C T

ISOL. SIGNAL A,J,E,W L.S. TO RWCU-FCV-33 ZONE (B/8)

RWCU-V-107 RWCU-V-108 3/4"RWCU(55)-4-1 RWCU-V-105 G33-F105 4"RWCU(1)-4-3 CHEMICAL CLEAN CONN.

6"RWCU(1)-4-1 4"

6"RWCU(2)-4-1 CHEMICAL CLEAN CONN.

4"RWCU(2)-4-2 RWCU-V-16A 3/4"RWCU(51)-4-1 1"

G33-F016A RWCU-V-17A G33-F017A EDR DWG. M537 (H/10)

RWCU-V-18A 1"

G33-F018A RWCU-V-19A G33-F019A 3/4"RWCU(50)-4-5 3/4"RWCU(50)-4 RWCU-RV-3 EDR DWG.

M537 (H/10)

SEE NOTE 2d 4"

1"RWCU(54)-4-1 1"

RWCU-V-14A G33-F014A RWCU-V-15A G33-F015A 3/4"RWCU(51)-4-2 3/4"RWCU(51)-4 1"

RWCU-V-23A G33-F023A 3/4"RWCU(51)-4 RWCU-V-22A G33-F022A 3/4"RWCU(50)-4-6 3/4"RWCU(50)-4 RWCU-V-16B 3/4"RWCU(51)-4-3 1"

G33-F016B RWCU-V-17B G33-F017B EDR DWG. M537 (H/10)

RWCU-V-18B 1" G33-F018B RWCU-V-19B G33-F019B 3/4"RWCU(50)-4-7 3/4"RWCU(50)-4 DWG.

M537 (H/10) 1" RWCU-V-14B G33-F014B RWCU-V-15B G33-F015B 3/4"RWCU(51)-4 1"

RWCU-V-23B G33-F023B 3/4"RWCU(51)-4 RWCU-V-22B G33-F022B 3/4"RWCU(50)-4-8 3/4"RWCU(50)-4 EDR RWCU-HX-1A G33-B001A REGENERATIVE HEAT EXCHANGER RWCU-HX-1B G33-B001B REGENERATIVE HEAT EXCHANGER RWCU-HX-2A G33-B002A NON REGENERATIVE HEAT EXCHANGER RWCU-HX-2B G33-B002B NON REGENERATIVE HEAT EXCHANGER RWCU-V-16C 3/4"RWCU(51)-4-5 1"

G33-F016C RWCU-V-17C G33-F017C EDR DWG. M537 (H/10)

RWCU-V-18C 1" G33-F018C RWCU-V-19C G33-F019C 3/4"RWCU(50)-4-9 3/4"RWCU(50)-4 DWG.

M537 (H/10) 1" RWCU-V-14C G33-F014C RWCU-V-15C G33-F015C 3/4"RWCU(51)-4-6 3/4"RWCU(51)-4 1"

RWCU-V-23C G33-F023C 3/4"RWCU(51)-4 RWCU-V-22C G33-F022C 3/4"RWCU(50)-4-10 3/4"RWCU(50)-4 EDR RWCU-HX-1C G33-B001C REGENERATIVE HEAT EXCHANGER 1"RWCU(54)-4 RWCU-RV-1 1"RWCU(54)-4-2 DWG.

M537 (H/11)

RWCU-V-24A G33-F024A RWCU-V-25A G33-F025A 3/4"RWCU(51)-4-7 3/4"RWCU(51)-4 RWCU-V-29A G33-F029A RWCU-V-30A G33-F030A 3/4"RWCU(50)-4 EDR 1"RWCU(54)-4 ABANDONED IN PLACE 3/4"RWCU(50)-4-11 4"RWCU(1)-4-4 3/4"RWCU(54)-4-3 6"RCC(7)-1 SEE DWG.

M525 (F/6) 6"RCC(6)-1 SEE DWG.

M525 (H/6) 6" DWG.

M537 (H/11)

RWCU-V-24B G33-F024B RWCU-V-25B G33-F025B 3/4"RWCU(51)-4 RWCU-V-29B G33-F029B RWCU-V-30B G33-F030B 3/4"RWCU(50)-4 EDR 3/4"RWCU(50) 12 3/4"RWCU(51)-4-8 RWCU-4 RWCU-3 6"RWCU(1)-3-1 RWCU-V-710 PI 4

RWCU RWCU-V-906(V)

G33-R004 TS 20 RWCU AH G33-N020 TE 19 RWCU G33-N019 TO RWCU-T/SS-601 ZONE (C/11)

TE 7

RWCU G33-N007 TIS 8

RWCU G33-N008 ISOLATION VALVE TRIP SYSTEM 4"RWCU(1)-3-3 CHEMICAL CLEAN CONN.

4" RWCU-V-603(V)

RWCU-V-462(V) 3/4"RWCU(53)-3-1 6"RWCU(7)-3-1 RWCU-V-44 MO 44 RWCU RMS G33-FO44C O

C RO 3

RWCU RWCU-3 RWCU-3S RWCU-3 RWCU-V-765 RWCU-V-766(TH)

RWCU-V-767(TH)

RWCU-V-768 RWCU-V-769 FOR CONT. SEE ZONE (C/14)

SEE NOTE 2d SEE NOTE 2f RWCU-V-454(V)

RWCU-V-606(V) 3/4"RWCU(53)-3-6 RWCU-V-456(D)

RWCU-V-610(D) 3/4"RWCU(52)-3-1 RWCU-V-609(V)

RWCU-V-455(V) 3/4"RWCU(53)-3-7 3/4"RWCU(60)-3-2 RWCU-V-723 PI 8

RWCU G33-R008 RWCU-V-907(V)

SEE NOTE 2d 6"RWCU(2)-3-1 RWCU-V-709 PI 803 RWCU G33-R003 RWCU-V-905(V)

RWCU-V-622(D)

RWCU-V-601(D) 3/4"RWCU(52)-4-3 TE 6

RWCU G33-N006 3/4"RWCU(60)-4-11 TE 15 RWCU C

G33-N015 RWCU-V-42 MO 42 RWCU G33-F042 RMS O

C 6"RWCU(2)-4-1 RO 2

RWCU RWCU-4 RWCU-4S RWCU-4 RWCU-V-104 MO 104 RWCU RMS G33-F104 O

C 6"RWCU(6)-4-1 6"RWCU(1)-4-1 TE 4

RWCU G33-N004 T/SS 601 RWCU G33-N601 FROM RWCU-TE-19 ZONE (K/6)

MV/I 601 RWCU G33-K601 C

TI 607 RWCU G33-R607 T

RWCU-V-707 RWCU-V-904(V) 3/4"RWCU(60)-4-8 PI 1

RWCU G33-R001 PT 5

RWCU G33-N005 PI 600 RWCU G33-R600 RWCU-V-39 G33-F039 RWCU-V-40 RWCU-V-137 RWCU-V-136 3/4"RWCU(55)-4-3 (TEST)

(LINE "A")

24"RFW(1)-4 DWG. M529 (G/13)

(LINE "B")

24"RFW(1)-4 DWG. M529 (G/4)

THERMAL SLEEVE X-17A X-17B THERMAL SLEEVE 4"RFW(11)-4 FE 40 RWCU G33-N040 RWCU-V-725 RWCU-V-724 FT 41 RWCU E31-N041 RWCU-V-913(V)

RWCU-V-912(V)

SQRT 603 RWCU E31-K603 3/4"RWCU(60)-4-10 C

1/2"PI(1)ST-RWCU-FT-41 (LOW) 3/4"RWCU(60)-4-9 1/2"PI(1)-ST-RWCU-FT-41(HIGH)

TO LEAK DET. SYSTEM LD-SUM-604 (ZONE D/11)

TEST 6"RWCU(2)-4-1 4"RWCU(2)-4-3 CHEM. CLEAN CONN.

MO 40 RWCU G33-F040 RMS T

O C

RWCU-4 RFW-4 6"

4"RFW(11)-4 PRIMARY CONTAINMENT TE 21 G33-N021 TO WATER TIGHT JUNCTION BOX DWG. M529 (J/8)

N-15 DRAIN 2"RRC(51)-4-5 DWG. M530-1 (F/9) 4"RRC(51)-4-3 DWG. M530-1 (F/9) 3"RCC(51)-4-3 2"RCC(51)-4-3 CONTR 215 CONTR 2 RWCU-4 RCC-4 RRC-4 RWCU-4 MO 101 RWCU G33-F101 F3 RMS O

C 6"

4"RWCU(4)-4-1 2"RWCU(4)-4-2 B35-COO1A 4"RWCU(3)-4-2 4"RWCU(3)-4-2 FT 37 RWCU X-78C G33-N037 SEE NOTE 8 SEE NOTE 7 FI 610 RWCU G33-R610 RWCU-V-914(V)

RWCU-V-915(D)

NOTE 2a NOTE 2d FROM PRESSURE BELOW CORE PLATE SENSING LINE. DWG.

M530 (G/4) 1"PI(1)-4S-X78c RO X78C PI PI-4S RRC-4 RWCU-V-37 RWCU-V-38 3/4"RWCU(55)-4-4 G33-F038 G33-F037 4"RCC(4)-4S-1 24"RCC(2)-4S DWG. M530-1 (B/13)

RECIRCULATION PUMP RRC-P-1B B35-COO1B 4"RCC(4)-4S-2 RECIRCULATION PUMP 24"RCC(2)-4S DWG. M530-1 (B/5)

RWCU-V-106 MO 106 RWCU G33-F106 O

C F5 RMS RWCU-4 RCC-4S 4"RWCU(3)-4-4 CHEMICAL CLEAN CONN.

RWCU-V-100 MO 100 RWCU G33-F10O O

C F2 RMS RCC-4S RWCU-4 4"RWCU(3)-4-3 CHEM. CLEAN CONN.

4"RWCU(3)-4-1(CL.1) 6"RWCU(3)-4-1(CL.1)

X-14 RWCU-V-102 RWCU-V-605(D)

RWCU-V-604(D) 3/4"RWCU(52)-4-1 FE 35 RWCU G33-N035 6"RWCU(3)-4-1(CL.1) 1/2" 1/2" RO X79B PI RO X79A PI X-79B X-79A 1"PI(1)-4S-X79b 1"PI(1)-4S-X79a MO 102 RWCU G33-F102 F4 RMS FI 609 RWCU SQRT 602 RWCU FT 36 RWCU C

G33-R609 E31-K602 E31-N036 TO LEAK DET. SYSTEM LD-SUM-604, ZONE (D/11)

NOTE 2a NOTE 2b NOTE 8 NOTE 7 DPIS 25 RWCU G33-N025 AL RWCU-P-1A&1B (B-D/13)

RWCU-V-903(V)

RWCU-V-902(V) 1"RWCU(54)-4 3/4"RWCU(51)-4-4 3/4"RWCU(52)-4-2 3/4"RWCU(60)-4-1 3/4"RWCU(1)-3 1/2"RWCU(7)-4S 3/4"RWCU(60)-3-1 RMS TIS 2B AH FROM RWCU-DPIS-25 ZONE (F/14)

FROM CRD-FS-2B DWG. M523-2 ZONE (C/9)

PUMP 1B INTERLOCK RMS TIS 2A AH FROM CRD-FS-2A DWG. M523-2 ZONE (H/9)

FROM RWCU-DPIS-25 ZONE (F/14)

PUMP 1A INTERLOCK 4"

6" CONT. FROM ZONE (C/2)

RADWASTE BLDG. CORRIDOR 4"

NOTE 2d NOTE 2a SEE NOTE 2C ZONE (B/8)

G33-N002B G33-C001A G33-C001B G33-N002A 3/4"RWCU(53)-4-2 RWCU-V-459(V)

RWCU-V-460(V)

RWCU-V-623(V)

RWCU-V-624 3/4"PSR(53)-4S CONT. ON M607-4 (D/10)

PSR-4S RWCU-4 RWCU-V-613(V)

RWCU-V-614(V) 3/4"RWCU(53)-4 RWCU-V-625 3/4"PSR(53)-4S CONT ON M607-4 (H/10)

RWCU-V-626(V)

RWCU-4 PSR-4S G33-N013 G33-F035 102 6-25-04 CORRECTED INCORPORATION OF TYPO FROM 01553-008 (G/5).

DMS KL SRP RWCU-V-101 RWCU-V-103 103 12-28-04 REVISED PER 03387-300 (F/13).

RAK HL SRP 104 10-14-05 CORRECTED INCORPORATION OF 01553-008 (B-C/12-13)

KB SRP CBS