ML053270115

From kanterella
Jump to navigation Jump to search
Drawing M523-2, Rev 6, Flow Diagram Reactor Water Clean Up System. Sheet 2 of 2
ML053270115
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 10/14/2005
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M523-2, Rev 6
Download: ML053270115 (1)


Text

CHEMICAL CLEANING CONNECTION 4"RWCU(57)-4-2 1/2"RWCU(51)-4-2 CHEMICAL CLEANING CONNECTION 1/2"RWCU(1)-4-1 CHEMICAL CLEANING CONNECTION 1/2"RWCU(50)-4-2 CHEMICAL CLEANING CONNECTION 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"RWCU(50)-4-1 1/2"RWCU(51)-4-2 3/4" 1/2"CRD(14)-4S 1/2"CRD(51)-4S 1/2"CRD(50)-4S 1/2"CRD(14)-4S EDR CRD 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"RCC(52)-1 EDR RCC 1/2"RCC(53)-1 4"RWCU(1)-4-2 4"RWCU(57)-4-6 RWCU PUMP ROOM 1B 3/4"RWCU(57)-4-2 PORTABLE FLOW INDICATOR 3/4"RWCU(57)-4-6 EDR RWCU TO 3"RCC(29)-1 CONT. ON DWG M525-2 (D/9) 1/2"RWCU(50)-4-4 CONT. FROM DWG M528-2 (E/1)

TO CONTROL ROOM M523-1 (B/14) 1 1/4" 3/4" EDR CRD 2"EDR(1)-1 3" EDR RWCU EDR 5"RWCU(3)-4-6 4"RWCU(3)-4-6 EDR RWCU EDR RCC 1 1/4" 1 1/4" CONT. ON DWG M525-2 (D/8)

DWG M537 (F/9)

DWG M537 (F/10) 2 1/2"RCC(28)-1 2 1/2"RCC(29)-1 PORTABLE FLOW INDICATOR 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"RWCU(51)-4-1 4"RWCU(57)-4-1 3/4" 1/2"CRD(14)-4S 1/2"CRD(51)-4S 1/2"CRD(50)-4S 1/2"CRD(14)-4S EDR CRD 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"EDR(1)-1 1/2"RCC(52)-1 EDR RCC 1/2"RCC(53)-1 4"RWCU(1)-4-1 4"RWCU(59)-4-1 RWCU PUMP ROOM 1A 3/4"RWCU(57)-4-1 PORTABLE FLOW INDICATOR 3/4"RWCU(59)-4-1 EDR RWCU TO 3"RCC(29)-1 CONT. ON DWG M525-2 (D/8)

NOTES:

1. FOR NOTES AND LEGEND SEE M523-1.

1/2"RWCU(50)-4-3 CONT. FROM DWG M528-2 (D/1)

EDR CRD 2"EDR(1)-1 3" EDR RWCU EDR 5"RWCU(3)-4-1 4"RWCU(3)-4-1 EDR RWCU TO CONTROL ROOM M523-1 (E/14) 1 1/4" 3/4" EDR RCC 1 1/4" 1 1/4" CONT. ON DWG M525-2 (D/8) 2 1/2"RCC(28)-1 2 1/2"RCC(29)-1 PORTABLE FLOW INDICATOR AL O

C RMS O

C RMS MO AL MO AL O

C RMS RMS O

C MO AL MO 2

1 3

15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 4

5 6

7 8

9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3

1 2

A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE NORTHWEST CHECKED SCALE DRAWN DWG NO.

REV.

FLOW DIAGRAM REACTOR WATER CLEAN UP SYSTEM M523-2 2 OF 2 6

NTS B. L. STAFFORD 1-22-02 K BOOTHROYD 01-23-02 DR JACOBSEN 04-29-02 SERVER84\\00\\dwg 5

04-29-02 REDRAWN PER 01553-009 BLS KB DRJ RWCU-V-5A RWCU-QDC-2A RWCU-V-758 RWCU-V-757 RWCU-QDC-1A RWCU-V-783A RWCU-V-13A RWCU-V-759 RWCU-V-760 RCC-V-643A RWCU-V-12A RWCU-P-1A CRD-V-503A CRD-V-510A CRD-V-502A CRD-V-504A CRD-V-505A RWCU-V-779A RWCU-V-780A FG 15A EDR CRD-FCV-512A CRD-V-501A FS 2A CRD FG 11A EDR CRD-V-511A CRD-V-506A CRD-V-507A CRD-V-508A CRD-V-509A RWCU-V-784A RWCU-HX-3A FG 12A EDR RCC-V-166A FG 13A EDR RWCU-V-781A RWCU-V-782A RCC-V-45A FS 1A RCC RCC-V-165A FG 14A EDR RWCU-V-785A RWCU-V-5B RWCU-V-754 RWCU-V-753 RWCU-QDC-2B RWCU-V-783B RWCU-V-755 RWCU-V-756 RWCU-QDC-1B RCC-V-643B RWCU-V-13B RWCU-V-781B RWCU-V-782B RWCU-V-12B RWCU-HX-3B RWCU-P-1B RCC-V-166B CRD-V-510B CRD-V-503B CRD-V-502B CRD-V-505B CRD-V-504B CRD-V-511B CRD-FCV-512B RWCU-V-779B RWCU-V-780B FG 15B EDR FS 2B CRD CRD-V-501B FG 11B EDR CRD-V-508B CRD-V-507B CRD-V-506B CRD-V-509B RWCU-V-784B RWCU-V-785B RCC-V-165B FG 12B EDR FG 13B EDR FS 1B RCC RCC-V-45B FG 14B EDR 6"RWCU(3)-4-1(CL.3)

CONT. FROM DWG.

M523-1 (C/13) 6"RWCU(1)-4 CONT. ON DWG.

M523-1 (C/12)

SEE M523-1 FOR PUMP INTERLOCK INFORMATION SEE M523-1 FOR PUMP INTERLOCK INFORMATION SEE NOTE 2f SEE NOTE 2d SEE NOTE SEE NOTE 2d 2f 6

10-14-05 CORRECTED INCORPORATION OF 01553-009 (E,K/11, H/13)

KB SRP CBS