Drawing M544, Rev 69, Flow Diagram HVAC - Standby Gas Treatment Reactor Building
ML053270147
Person / Time
Site: Columbia 
Issue date: 09/01/2005
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M544, Rev 69
Download: ML053270147 (1)


Text

2 1

3 15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 R0 (9/94)

DWN CHK APVD 4

DESCRIPTION 5

6 DATE REV 7

8 9

10 11 12 COLUMBIA GENERATING STATION TITLE DATE SIGNATURE REV.

APPROVED CHECKED SCALE DRAWN 3

1 2

DWG NO.

A FLOW DIAGRAM HVAC-STANDBY GAS TREATMENT REACTOR BUILDING M544 69 N.T.S.

4WARDTECH 6-17-99 K. LUCAS 2-7-02 SCOTT PAYNE 2-8-02 SERVER84\\00\\G ALL INSTRUMENTATION ON THIS DRAWING TO BE PREFIXED BY "SGT" UNLESS SPECIFICALLY NOTED OTHERWISE, ie; IS IDENTIFIED AS SGT-TE-9A ISOLATION SIGNAL CODES A - REACTOR VESSEL LOW WATER LEVEL F - HIGH DRYWELL PRESSURE Z - HIGH RADIATION, REACTOR BUILDING VENTILATION SYSTEM FOR FLOW DIAGRAM LEGEND, SYMBOLS, AND ABBREVIATIONS SEE DRAWING M501 EXCEPT AS NOTED HEREIN FILTER TEST INJECTION AND SAMPLING

  • - INSTRUMENTS AND ACCESSORIES FURNISHED BY EQUIPMENT SUPPLIER. (CONTRACT #18)

ALL TAGS FOR CHECK VALVES WILL BE FURNISHED AND INSTALLED BY OWNER.

ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DWG. ARE CLASSIFIED AS FOLLOWS EXCEPT 18"CEP(2)-1 AND AS NOTED OTHERWISE:

SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP B (CODE STAMP IS NOT REQ'D) 18"CEP(2)-1 IS CLASSIFIED AS FOLLOWS:

SEISMIC CATEGORY II QUALITY CLASS II CODE GROUP D AIR QUANTITIES INDICATED AS CFM ARE STANDARD (SCFM). ACTUAL CFM INDICATED AT FAN ARE ACFM. CONTRACTOR SHALL ADJUST VARIABLE INLET VANES AT FANS TO SUIT RANGE OF 500 TO 4000 ACFM.

ALL TAGS FOR INSTRUMENT ROOT VALVES WILL BE FURNISHED AND INSTALLED BY OWNER.

ALL PRESSURE AND FLOW INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.

DRAIN PIPING AS NOTED ONLY:

SEISMIC CATEGORY I QUALITY CLASS I

    • INSTRUMENT AND ACCESSORIES FURNISHED BY CONTRACT 215 AS REPLACEMENT PARTS IDENTICAL TO ORIGINAL EQUIPMENT NOTES SP TE 9A 1.

POINT 2.

3.

5.

6.

7 8.

9.

10.

11.

4.

THIS SECTION OF LINE IS CLASSIFIED AS FOLLOWS:

SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP B*

  • NO CODE STAMP REQUIRED. DESIGN, FABRICATION, INSTALLATION, & EXAMINATION SHALL MEET THE REQUIREMENTS OF ASME III-2. HOWEVER THE PNEUMATIC TEST IS WAIVED.

DELETED INSTRUMENT TUBING ON UNITS SGT-FU-1A & 1B ARE CLASSIFIED AS FOLLOWS:

SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP D THE 20"x 20" DUCT (SHOWN AS DOTTED LINE CONTRACT 216) NO LONGER SERVES ANY PURPOSE AND IS ABANDONED IN PLACE.

THE EXTENSION OF THE 6"OFF-GAS LINE SEISMIC CATEGORY II (WITH SEISMIC CATEGORY I SUPPORTS)

QUALITY CLASS II +

CODE GROUP D +

AIR OPERATED VALVE IS FAIL CLOSED AND SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP C ALL OTHER COMPONENTS IN DETAIL ARE QC II, CODE GROUP D, SC II (SEE 15Q.

215 SPEC FOR SUPPORTS, PG 15Q-49b).

TRUE ORIENTATION IS OPPOSITE THAN SHOWN:

FACING INLET ENDS, "A" TRAIN IS ON THE RIGHT, "B" TRAIN IS ON THE LEFT.

12.

13.

14.

15.

16.

17.

1/4" MD(99)-1 FROM DETAIL "E", ZONE (A/13) 1/4" MD(99)-1 FROM DETAIL "D", ZONE (F/13) 1/4" MD(99)-1 FROM DETAIL "C", ZONE (F/11) 1/4" MD(99)-1 FROM DETAIL "B", ZONE (F/8) 1/4" MD(99)-1 1/4" MD(99)-1 1/4" MD(99)-1 FROM DETAIL "F", ZONE (A/11) 1/4" MD(99)-1 FROM DETAIL "G", ZONE (B/10) 3"MD-V-102 LC 3"

3" DRAIN SEAL 3"MD(99)-1

  1. 216
  1. 215 CONTRACT CONTRACT DETAIL "A" DRAIN AO SGT/46 FP FP-V-SGT/42 FP-SPV-SGT/46 RMS FP FP-V-SGT/46 (NOTE 16) 6"RD(2)-1 1/4"MD(99)-1 SEE DET. "A" PI SGT/8BI FP A

PS SGT/8BI FP FP-V-SGT/41 L.O.

DETAIL "E" FP-V-74 L.O.

EDR-TO FDR SYST DWG M539 (H/9)

FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (D/2)

PI SGT/8B2 FP ATMOS FP-V-SGT/44 DRAIN AO SGT/56 FP FP-SPV-SGT/56 RMS FP FP-V-SGT/56 (NOTE 16)

PI SGT/6BI FP A

PS SGT/6BI FP FP-V-SGT/51 L.O.

DETAIL "F" FP-V-75 FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (C/2)

PI SGT/6B2 FP ATMOS FP-V-SGT/54 L.O.

FP-SPV-SGT/66 RMS FP ATMOS AO SGT/66 FP FP-V-SGT/63 PI SGT/7B2 FP A

PS SGT/7BI FP FP-V-SGT/61 FP-V-76 FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (C/2)

PI SGT/7B1 FP FP-V-SGT/703B L.O.

DRAIN L.O.

DETAIL "G" SGT-V-56B SGT-V-57B SGT-V-58B SGT-V-59B SGT-V-60B SGT-V-61B SGT-V-62B TE 7B1 TS 7B1 TE 7B MV/I 7B TI 7B TS 7B C

A H A H 2"SGT(50)-1 2"FP(60)-1 DWG. M515-5 (C/2)

SGT-V-63B SGT-V-64B SGT-V-65B SGT-V-66B SGT-V-67B SGT-V-68B SGT-V-69B SGT-V-70B SGT-V-71B 2"

(TYP)

EDR-TO FDR SYST DWG M539 (H/10)

NOTE 6 SEE NOTE 10 SEE NOTE 6 SEE NOTE 10 SEE SGT-MS-1B SGT-EHC-1B1 TI 8B ME 17B TS abc TS d

MT 17B MI 7B RMS 2"SGT(50)-1 C

SEE TABLE 1 SGT-V-55B SGT-V-54B NOTE 6 SEE NOTE 10 SEE TS 8B1 A H SGT-V-53B NOTE 6 SEE NOTE 10 SEE 1 1/2"FP(60)-1 DWG. M515-5 (D/3)

TE 8B1 TE 6B MV/T 6B TI 6B TS 6B A H ME 4B MT 4B MI 4B A H MS 4B C

A H (DIV. I)

SGT-EHC-1B2 (DIV. II)

SGT-V-52B SGT-V-51B NOTE 6 SEE NOTE 10 SEE SGT-FL-1B SGT-HF-1B1 SGT-ESH-1B SGT-CF-1B1 SEE NOTE 10 SEE NOTE 6 SGT-CF-1B2 SGT-HF-1B2 SP 1B SGT-V-725 HIGH EFFICIENCY FILTER (HEPA)

TS 2B31 TS 2B41 TI 10B A H A

L TC 2B2 SGT-V-714B SGT-V-715B SGT-V-730B SGT-V-731B DPIS 6B A H C

4000 CFM IODINE ADSORBER ACTIVATED CARBON 2.1kW (DIV. II)

ELEC STRIP HEATER SGT-ESH-2B 2.1kW ELEC STRIP HEATER (DIV. II)

DPIS 5B A H SGT-V-712B SGT-V-713B C

TS 2B11 TS 2B21 TC 2B1 RMS TO STRIP HEATER SGT-ESH-2B TS 1B11 MI 5B ME 5B TS 1B21 TC 1B1 TS IB3/4 A

L A H RMS TO STRIP HEATER SGT-ESH-1B TS 1B31 MI 3B ME 3B TS 1B41 TC 1B2 TI 9B A

H A

L TE 6B1 TS 6B1 C

DPIS 4B A H SGT-V-710B SGT-V-711B C

RMS DPIS 3B A H SGT-V-708B SGT-V-709B C

DPIS 2B A H SGT-V-706B SGT-V-707B C

PREFILTER TS abc TS d

C SEE TABLE 1 ME 16B MT 16B MI 6B 20.7kW ELECTRIC HEATING COILS 20.7kW TE 1B MV/I 1B C

DPIS 1B A H C

SGT-V-704B SGT-V-705B TI 1B TS 1B A H CODE GROUP D (TYP)

(NOTE 14)

STAND-BY-GAS TREATMENT UNIT SGT-FU-1B MOISTURE SEPARATOR HIGH EFF.

FILTER (HEPA)

TD ON A

L C

(DIV I)

FR 2B1 FS 1B1 LMTR 1B1 SQRT 1B1 T

RMS MO (DIV. I)

MO RMS (DIV I)

N.C.

18"SGT(1)-1 NOTE 6 SEE NOTE 12 MO RMS EHO 1B1 FO DPIC 1B1 SUM 1B1 RMS M

25 HP SP FT 1B1 FE 1B1 N.O.

FROM SECONDARY CONTAINMENT PRESSURE CONTROL SYSTEM A, DWG M545-3 (K/4)

SGT-AD-1B1 (4457 ACFM)

(DIV II)

AUTO CLOSE SIGNAL F, A, Z AUTO CLOSE SIGNAL F, A, Z MAIN HEATER TEMP SWITCHES 1ST STAGE CUTOUT a

2ND STAGE CUTOUT b

3RD STAGE CUTOUT c

OVERTEMP CUTOUT d

SGT-EHC-1A1 TS-EH1A12 TS-EH1A13 TS-EH1A11 SGT-EHC-1A2 TS-EH1A22 TS-EH1A23 TS-EH1A21 SGT-EHC-1B1 TS-EH1B12 TS-EH1B13 TS-EH1B11 SGT-EHC-1B2 TS-EH1B22 TS-EH1B23 TS-EH1B21 EHC #

TS-EH1A15 TS-EH1A16 TS-EH1A14 TS-EH1A25 TS-EH1A26 TS-EH1A24 TS-EH1B15 TS-EH1B16 TS-EH1B14 TS-EH1B25 TS-EH1B26 TS-EH1B24 TS-EH1A18 TS-EH1A19 TS-EH1A17 TS-EH1A28 TS-EH1A29 TS-EH1A27 TS-EH1B18 TS-EH1B19 TS-EH1B17 TS-EH1B28 TS-EH1B29 TS-EH1B27 THRU TS-EH1A118 TS-EH1A110 THRU TS-EH1A218 TS-EH1A210 THRU TS-EH1B118 TS-EH1B110 THRU TS-EH1B218 TS-EH1B210 TABLE 1 LEGEND SGT-V-723 SGT-V-722 1/2"SGT(60)-1 AUTO OPEN SIGNAL F, A, Z (DIV I)

SGT-FN-1B1 FE 1B2 TD ON C

A L

SP M

(DIV II)

SGT-FN-1B2 FIS 2B1 (DIV. I.)

RMS SGT-V-3B2 SGT-V-5B1 18"SGT(1)-1 MO RMS N.O.

(DIV I)

AUTO OPEN SIGNAL F, A, Z SGT-V-3B1 MO SGT-V-4B2 AUTO CLOSE SIGNAL F, A, Z N.C T

SUM 1B2 DPIC 1B2 EHO 1B2 FO RMS FR 2B2 FS 1B2 LMTR 1B2 SQRT 1B2 AUTO START SIGNAL F, A, Z (4457 ACFM)

SGT-AD-1B2 SGT-V-729 0-4000 CFM MO RMS AUTO OPEN SIGNAL F, A, Z SGT-V-5B2 18"SGT(1)-1 N.C.

SEE NOTE 6 SEE NOTE 12 (DIV. II.)

FT 1B2 SGT-V-721 SGT-V-720 1/2"SGT(60)-1 1/2"SGT(60)-1 AO MO (DIV. II)

SGT-V-2B (DIV II)

NO FO 18"SGT(1)-1 4000 CFM 18"SGT(1)-1 ROOM AIR RMS SGT-SPV-2B SF 1

NOTE 6 SGT-V-1B SGT(2)-1 18"SGT(1)-1 4"SGT(2)-1 SGT(1)-1 AUTO OPEN SIGNAL F, A, Z 4"SGT(2)-1 N.C.

CEP-1 SGT-1 RMS AUTO CLOSE SIGNAL F, A, Z FIRE WALL SEPARATION TD ON A

L C

(DIV II)

FR 2A2 FS 1A2 LMTR 1A2 SQ.RT 1A2 T

RMS MO (DIV. II.)

NC.

MO RMS (DIV II)

N.C.

18"SGT(1)-1 NOTE 6 NOTE 12 MO RMS EHO 1A2 FO DPIC 1A2 SUM 1A2 RMS M

25 HP SP FT 1A2 FE 1A2 N.O.

SGT-AD-1A2 (4457 ACFM)

(DIV I)

AUTO CLOSE SIGNAL F, A, Z SGT-V-716 SGT-V-718 1/2"SGT(60)-1 AUTO OPEN SIGNAL F, A, Z (DIV II)

SGT-FN-1A2 FE 1A1 TD ON C

A L

SP M

(DIV I)

SGT-FN-1A1 FIS 2A2 (DIV II)

RMS SGT-V-3A1 SGT-V-5A2 18"SGT(1)-1 MO RMS N.O.

AUTO OPEN SIGNAL F, A, Z SGT-V-3A2 MO SGT-V-4A1 AUTO CLOSE SIGNAL F, A, Z N.C T

SUM 1A1 DPIC 1A1 EHO 1A1 FO RMS FR 2A1 FS 1A1 LMTR 1A1 SQRT 1A1 AUTO START SIGNAL F, A, Z (4457 ACFM)

SGT-AD-1A1 SGT-V-728 MO RMS AUTO OPEN SIGNAL F, A, Z SGT-V-5A1 T

18"SGT(1)-1 (DIV I)

N.C.

NOTE 6 NOTE 12 (DIV I)

FT 1A1 SGT-V-717 SGT-V-719 1/2"SGT(60)-1 SGT-V-4B1 N.C.

SGT-V-4A2 AUTO CLOSE SIGNAL F, A, Z 0-4000 CFM 18"SGT(1)-1 25 HP 4000 CFM (DIV II)

FROM OFF GAS SYSTEM CONT. ON DWG. M511 (K/15)

PRM-P-1 REA-V-19 REA-V-20 REA-F-9B REA-F-10B REA-F-9A REA-F-10A REA-V-100 RSM 94 REA RB 647'-4" FE 1B PRM FE 1A PRM FIT 1

PRM DPT 2

PRM SQRT 2

PRM C

T 23026 C

STACK FLOW SAMPLE FLOW FI 2

PRM RMS 1

PRM OFF/ON TO PRM-FR-1 (J/2)

PRM-CAB-2 RB 606' PRM-V-1 PI 1

RB 648'-3" ELEVATED RELEASE PT.

TO ATMOSPHERE FOR STACK MONITOR DETAILS SEE FIG I (J/4)

RE N010 D17 FROM REACTOR BLDG VENTILATION SYSTEM 6"

FROM OFF-GAS SYSTEM CONT.

ON DWG. M535-2 (K/1) 14"AR CONTR. 216 206 CONT.

215 CONT.

NOTE 6 NOTE 16 SEE NOTE 15 SP 2B TE 8B C

SGT-V-727 SGT-V-726 SP 2A TE 8A C

215 CONT.

16"SGT(1)-1 18"SGT(1)-1 18"SGT(1)-1 PRM-C-1A PRM-C-1C PRM-C-1B ELECTRICOOL PRM-REC-1A ELECTRICOOL PRM-REC-1C ELECTRICOOL PRM-REC-1B RE 1B PRM RE 1C PRM RE 1A PRM EL.611'-10" EL.618'-7" EL.618'-7" FLOW TT 1

PRM TIC 1B PRM TIC 1C PRM TS 2

PRM-AC-2 TS 1

PRM-AC-1 PRM-CAB-1 RB 606' TE 1

PRM TIC 1A PRM FIGURE 1 (ZONE G/3)

FR 1

PRM A

SAMPLE FLOW LOW STACK FLOW HIGH FROM PRM-CAB-2 (F/1)

T 23012 T

23011 T

23034 A

L T

RR 32 ARM RIS 32 ARM RE 32 ARM RI 32 ARM A H PRM-CP-1 RW 525' P814 CONTROL ROOM RMS FP A

FP-V-71 LO EDR-TO FDR SYST DWG M539 (H/10)

RMS FP RMS FP TE 7A1 TS 7A1 TE 7A MV/I 7A TI 7A TS 7A C

A H A H 2"SGT(50)-1 2"FP(60)-1 DWG. M515-5 (D/4)

SGT-V-65A SGT-V-66A SGT-V-67A SGT-V-68A SGT-V-69A SGT-V-70A SGT-V-71A 2"(TYP)

NOTE 6 SEE NOTE SEE SGT-MS-1A SGT-EHC-1A1 TI 8A ME 17A TS abc TS d

MT 17A MI 7A RMS C

SEE TABLE 1 SGT-V-55A SGT-V-54A NOTE 6 SEE NOTE 10 SEE TS 8A1 A H SGT-V-53A NOTE 6 SEE NOTE 10 SEE 1 1/2"FP(60)-1 DWG. M515-5 (D/3)

TE 8A1 TE 6A MV/I 6A TI 6A TS 6A A H ME 4A MT 4A MI 4A A H MS 4A C

A H (DIV II)

SGT-EHC-1A2 (DIV I)

SGT-V-52A SGT-V-51A NOTE 6 SEE NOTE 10 SEE SGT-FL-1A SGT-HF-1A1 SGT-ESH-1A SGT-CF-1A1 SEE NOTE 10 SEE NOTE 6 SGT-CF-1A2 SGT-HF-1A2 HIGH EFFICIENCY FILTER (HEPA)

TS 2A31 TS 2A41 TI 10A A H A

L TC 2A2 SGT-V-730A SGT-V-731A SGT-V-714A SGT-V-715A DPIS 6A A H C

4000 CFM IODINE ABSORBER ACTIVATED CARBON 2.1kW (DIV. I)

ELEC STRIP HEATER SGT-ESH-2A 2.1kW ELEC STRIP HEATER (DIV I)

DPIS 5A A H SGT-V-712A SGT-V-713A C

TS 2A11 TS 2A21 TC 2A1 RMS TO STRIP HEATER SGT-ESH-2A TS 1A11 MI 5A ME 5A TS 1A21 TC 1A1 TS 2A1/2 TS 1A3/4 A

L A H RMS TO STRIP HEATER SGT-ESH-1A TS 1A31 MI 3A ME 3A TS 1A41 TC 1A2 A

H A

L TE 6A1 TS 6A1 C

DPIS 4A A H SGT-V-710A SGT-V-711A C

RMS DPIS 3A A H SGT-V-708A SGT-V-709A C

DPIS 2A A H SGT-V-706A SGT-V-707A C

PREFILTER TS abc TS d

C SEE TABLE 1 ME 16A MT 16A MI 6A 20.7kW ELECTRIC HEATING COIL TE 1A MV/I 1A C

DPIS 1A A H C

SGT-V-704A SGT-V-705A TI 1A TS 1A A H GROUP D (TYP)

HIGH EFFICIENCY FILTER (HEPA)

EDR - TO FDR SYST.

DWG. M539 (H/11)

SEE NOTE 10 SEE NOTE 6 SGT-V-57A SGT-V-56A SGT-V-58A SGT-V-59A SGT-V-60A SGT-V-61A SGT-V-62A SGT-V-63A SGT-V-64A FP-V-73 FP-V-72 LO 2"FP(60)-1 DWG M515-5 (D/3)

SP 1A (MANUAL FULL BOX VALUE) 2"SGT(50)-1 FP-SPV-SGT/36 ATMOS A

FP-V-SGT/31 FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (D/3)

PI SGT/6A2 FP 1/4"MD(99)-1 SEE DET. "A" L.O.

DETAIL "B" FP-V-SGT/703A FP-V-SGT/702A FP-V-SGT/702B FP-V-SGT/64 FP-V-SGT/701B A

(NOTE 16)

FP-SPV-SGT/16 ATMOS DETAIL "C" FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (D/3)

FP-V-SGT/21 L.O.

SEE NOTE 17 FP-V-SGT/16 (SEE NOTE 16)

FROM 4"FP(60)-1 CONT. ON DWG. M515-5 (D/2)

FP-V-SGT/11 L.O.

DETAIL "D" FP-V-SGT/24 PI SGT/8A2 FP FP-V-SGT/14 FP-SPV-SGT/26 FP-V-SGT/13 ATMOS.

1/4"MD(99)-1 SEE DET. "A" FP-V-SGT/701A DRAIN SF 2

18"CEP(2)-1 18"CEP(2)-1 4"SGT(3)-1 (CROSS-TIE) 18"CEP(2)-1 0-4,000 CFM RMS AO 18"SGT(1)-1 MO RMS SGT-V-1A (DIV. I)

SGT-1 CEP-1 N.C.

AUTO CLOSE SIGNAL F, A, Z SGT(1)-1 SGT(3)-1 NOTE 6 4"SGT(3)-1 SGT-V-724 4000 CFM 18"SGT(1)-1 MOISTURE SEPARATOR (NOTE 14)

CODE STAND-BY-GAS TREATMENT UNIT SGT-FU-1A SGT-SPV-2A SGT-V-2A (DIV I)

NO FO 18"SGT(1)-1 ROOM AIR AUTO OPEN SIGNAL F, A, Z CODE GROUP D 10 LO.

1/4"MD(99)-1 SEE DET. "A" 25HP 18"SGT(1)-1 (OG(28)-3) IS CLASSIFIED AS FOLLOWS:

FSAR FIG.

RO SGT/6A1 FP RO SGT/7A1 FP RO SGT/8A1 FP O

C O

C T

O C

O C

(DIV II)

T O

C O

C T

O C

O C

TS 2B3/4 O

C O

C TS 2A3/4 O

C TS 1A1/2 TI 9A PS SGT/7A1 FP PS SGT/6A1 FP PI SGT/8A1 FP PI SGT/7A1 FP PI SGT/7A2 FP AO SGT/26 FP AO SGT/36 FP TS 1B1/2 TS 2B1/2 FP-V-SGT/53 RO SGT/6B1 FP AO SGT/16 FP PS SGT/8A1 FP O

C O

C O

C O

C O

C SGT-FLX-3 SGT-FLX-4 SGT-FLX-5 SGT-FLX-6 SGT-FLX-8 SGT-ES-2 SGT-FLX-7 SGT-ES-1 INTERMEDIATE RANGE SIGNAL PROCESSING PRM-LCRM-1B PRM-RA-1B PRM-XAY-1B HIGH RANGE SIGNAL PROCESSING PRM-LCRM-1C PRM-RA-1C PRM-XAY-1C LOW RANGE SIGNAL PROCESSING PRM-LCRM-1A PRM-RA-1A PRM-XAY-1A PRM-COMP-1 O/M 1

PRM PRM-IN-1 CPL 1

PRM PRM-COMP-3 O/M 3

PRM RO SGT/7B1 FP

1. ESH - ELECTRIC STRIP HEATER ED - EQUIPMENT DRAIN
2. ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

CONT. ON DWG.

M510-2A (J/5)

CONT. ON DWG.

M510-2A (H/5)

CONT. ON DWG.

M510-2A (H/6)

CONT. ON DWG.

M545-3 (H/11)

CONT. ON DWG.

M545-3 (F/11)

CONT.

ON DWG.

M557 (E/4)

CONTAINMENT FROM PRIMARY CONT. ON DWG.

M543-3 (J/9)

CONT.

ON DWG.

M557 (H/3)

FROM SECONDARY CONTAINMENT PRESSURE CONTROL SYSTEM "B" CONT. ON DWG.

M545-3 (G/6)

CONT. ON DWG.

M510-2A (H/6)

CONT. ON DWG.

M510-2A (J/6)

CONT. ON DWG.

M510-2A (J/6)

FROM SECONDARY CONTAINMENT PRESSURE CONTROL SYSTEM "B" CONT. ON DWG.

M545-3 (G/6) 2"FP(60)-1 DWG. M515-5 (C/2)

FROM SECONDARY CONTAINMENT PRESSURE CONTROL SYSTEM "A" CONT. ON DWG.

M545-3 (K/4)

CONT. ON DWG.

M545-3 (H/1)

TO PRM-RR-3 CONT. ON DWG.

M545-3 (F/11)

FROM ARM-RIS-33 CONT. ON DWG.

M543-1 (F/5)

FROM ARM-RIS-34 CONT. ON DWG.

M545-2 (K/5)

FROM ARM-RIS-34 CONT. ON DWG.

M545-2 (K/5)

FROM ARM-RIS-33 CONT. ON DWG.

M543-1 (F/5)

B. L. STAFFORD 8-8-00 68 9-21-04 REV PER 03261-200 (A/8-12, C/6-7,9-12, D/6-8, D-E/1-2, E/6, F/9-12, G/5-6, G-H/10-12, H/5-7, J/5-7).

JFT HL DRJ 67 9-12-02 REV PER 55-2887-0A-201 (B/8,10,12, G/9,10,12), 55-2887-0A-202 (B/8,10,12, G/9,10,12).

BLS KL SRP 66 2-8-02 REDRAWN PER 01475-004.

4WT/BLS KL SRP 2"

FP-ST-SGT/1A 1"

3/4" 1/2" 1/4" 1/4" 3/4" FP-V-SGT/23 FP-ST-SGT/2A 1/4" DRAIN 1/4" FP-V-SGT/26 1/4" PI SGT/6A1 FP FP-ST-SGT/3A FP-V-SGT/33 3/4" 1/4" 1/4" 1/2" FP-V-SGT/36 (NOTE 16) 1/2" DRAIN 1/4" 2"

1/4" 1/2" 3/4" 1/2" RO SGT/8B1 FP FP-ST-SGT/4A 1/4" 1/2" 1/4" 3/4" 1/4" 1/2" 1/2" FP-ST-SGT/5A 1/4" 1/4"MD(99)-1 SEE DET. "A" FP-V-SGT/66 (NOTE 16) 3/4" 1/2" 1/4" 1/4" FP-ST-SGT/6A 1/4"MD(99)-1 SEE DET. "A" 1/4" 1/2" 1/4" 2"

1/2" FP(60)-1 1/4" 1/2" 2"

2" FP-V-SGT/34 2"

1 1/2" 2"

(B\\15)

(B/14) 1/2" (B/15)

(B/15)

(B/14)

(B/15) 2" 69 9-1-05 REV PER 03587-200 (A-B/8-13, B/14-15, F-G/8-13)

H.AL BLS DRJ