TOP TIER 18"RHR(1)-2-7 2"RHR(27)-1-3 T
MO 42C RMS C
O 1/2"RHR(1)-4-7 RHR-V-42C E12-F042 14"RHR(1)-2-7 18"RHR(4)-1-3 (TEST LINE "C")
RHR-1 RHR-2 3/4"RHR(52)-1 3/4"RHR(52)-1-1 RHR-V-131C 1/2"RHR(60)-2 SEPARATOR RO 5C 18"RHR(1)-2-7 6"RHR(7)-2-3 RHR-V-144C 3/4"RHR(55)-2-19 RHR-V-704C RHR-V-748C RHR-V-31C 3/4"RHR(60)-2-57 RHR-V-736(D) 3/4"RHR(32)-2-6 (LOOP "C" RETURN TO RPV)
RHR-V-63C L.C.
COND-1 RHR-2 C.G.D C.G.B 3"RHR(17)-2-3 SUPPRESSION POOL SUPPRESSION CHAMBER RO 8C RO 9C 2"RHR(22)-1-1 RHR-RV-88C E12-F088 RHR-V-740(D)
RHR-V-701C 1"RHR(26)-1-3 3/4"RHR(60)-1-2 3/4"RHR(60)-1-3 3/4"RHR(52)-1-2 18"RHR(1)-2-7 18"RHR(4)-1-3 RHR-V-82 E12-F082 3/4"RHR(3)-1-5 RHR-P-3 REACTOR VESSEL RPV INVERT EL. 521'-0 1/4" 14"RHR(1)-4-7 RHR-V-56C E12-F056 RHR-V-57C E12-F057 3/4"RHR(55)-4-5 3/4"RHR(60)-4-3 3/4"RHR(55)-2-2 3/4"RHR(60)-2-45 RHR-V-708C RHR-V-211(V)
RHR-V-155C 3/4"RHR(55)-2-4 TEST CONN N6 12"RHR(1)-4-7 RHR-V-111C L.O.
C O
RHR-4S RHR-4 RHR-V-157C (SEE NOTE 24)
RHR-V-158C (SEE NOTE 24) 3/4"RHR(55)-4-7 3/4"RHR(55)-4S-7 RHR-V-41C E12-F041 14"RHR(1)-4-7 AO 41C X-12c RHR-V-198 RHR-V-199 3/4"RHR(55)-4-6 X-62f PI-VX-62F 1"PI(1)-1-X62f PI-VX-228 3/4" PI-VX-220 L.C.
WATER LEVEL EL. 466'-4 3/4" MAX VENT STRAINER 24"RHR(3)-1-3 X-26 18" X-36 3/4"RHR(55)-1-25 RHR-V-4C E12-F004 T
RMS RHR-V-167C TEST CONN.
RHR-SPV-41C BLEED A
SEE NOTE 3D SEE NOTE 3C RHR-RV-25C E12-F025 1"RHR(1)-2-8 RHR-2 RHR-1 RHR-V-148 RHR-V-194 TEST CONN 3/4"RHR(55)-1-4 RHR-V-174 3/4"RHR(55)-1-3 T
RHR-V-21 E12-F021 RMS RHR-1 RHR-2 18"RHR(4)-2-3 TEST CONN RHR-V-149 3/4"RHR(55)-2-10 RHR-V-18C E12-F018 L.O.
RHR-V-197 RHR-V-196 3/4"RHR(55)-1-7 3/4"RHR(55)-1-6 RHR-V-46C E12-F046 DISK REMOVED 6"RHR(7)-1-3 RHR-V-195 3/4"RHR(55)-1-5 PX 11 PI 2C E12 R002 RO 7C RO 6C 3/4"RHR(60)-1-4 PX 12 RMS 1 1/2"RHR(12)-1-2 1"
RO 2
E12-D002 RHR-V-210 RHR-V-607(D)
RHR-V-109 RHR-1 COND-1 18"COND(79)-1 DWG. M527-1 (B/6) 24"RHR(3)-1-3 KEYLOCK 3"RHR(17)-1-1 (SUPPRESSION POOL SUPPLY LOOP "C")
RHR-1 COND-1 RHR-V-106 L.C.
RHR-V-203(V) 3/4"RHR(53)-1-2 1 1/2"RHR(13)-1-1 CONT. ON DWG.
M521-1 (B/7)
BLIND 18"RHR(21)-1-1 18"RHR(21)-1-2 RHR-V-108 3/4"RHR(53)-1-1 3/4"RHR(21)-1-2 RHR-V-640(V) 3"RHR(9)-1-6 RHR-V-71C 1 1/2"RHR(12)-1-2 RHR-V-84C E12-F084 SCUPPER DRAIN PORTABLE COLLECTOR 3/4" 14" 24"RHR(3)-1-3 RHR-V-45C RHR-V-44C N
1/2"RHR(1)-2 EA BA RHR-V-132C PS 16C PS 19C 1/2"PI(1)-ST 3/4"RHR(60)-2-53 RHR-V-133C 3/4"RHR(53)-2-4 3/4"RHR(56)-2 RHR-V-13C RHR-V-12C RHR-FCV-64C E12-F064 TEST CONN 3/4"RHR(55)-2-20 RO 1C RHR-1 RHR-2 RHR-2S 6"RHR(7)-2-3 C
O T
RMS C
T E12-N022 AH E12-N010 1 1/2"RHR(12)-2-2 RHR-V-85C S.C.
E12-F085 RHR-V-110C L.O.
E12-F098 RHR-V-729C 3/4"RHR(60)-2-52 3/4"RHR(60)-2-51 T
E12-N015 RHR-V-912(V) 1/2"PI(1)ST-(H22-P021)-B6 1/2" RHR-V-707C RHR-V-911(V)
RHR-V-706C 3/4"RHR(60)-2-47 3/4"RHR(60)-2-49 RHR-V-728C RHR-V-705C 3/4"RHR(60)-2-54 E12-N037 TO ADS NUCLEAR BOILER INTERLOCK 1/2"PI(1)-ST-(H22-P021)-B5 E12-N039 RHR-V-909(V)
AL 1/2"PI(1)-ST-(H22-P021)-B3 NOTES:
FOR NOTES SEE M521-1.
L.C.
1 1/2"RHR(12)-1-1 CONT. ON DWG.
M521-2 (B/5)
WATER LEG TO LOOP "B" 3"RHR(9)-2-3 CONT. ON DWG M521-2 (B/5)
CONT. ON DWG M521-2 (B/6)
(LOOP "C" CROSSTIE & COND. FILL)
C O
PIS 22C PS 39C E12-N019 E12-N016 RHR-HX-2C E12-C002 RHR PUMP M
RHR-P-2C PX 16 RHR-FLX-2C 3/4"RHR(53)-1 24"RHR(3)-1-3 24"RHR(3)-1-3 1/2"RHR(1)-2-12 E12-R612 3"
RHR-V-145C FIS 10C FE 14C FT 15C FI 603C E12-R603 3"COND(77)-1 FLUSH SUPPLY DWG. M527-1 (D/6)
CONTR.
213 CONTR.
215 RHR-ST-4A RHR-ST-4B SEE SEE SEE NOTE 15 NOTE 15 NOTE 3B L.C.
BLIND FLANGE 3"COND(48)-1 FLUSH SUPPLY DWG. M527-1 (G/8)
CONT. ON DWG.
M521-2 (E/13)
SEE NOTE 15 2
1 3
15 14 13 12 11 10 9
8 7
6 5
4 F
E D
C B
F E
D C
B K
J H
G K
J H
G 13 14 15 A
PDS2-E1 4
5 6
7 8
9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3
1 2
A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE CHECKED SCALE DRAWN DWG NO.
REV.
FLOW DIAGRAM RESIDUAL HEAT REMOVAL LOOP "C" M521-3 1
NONE L.W.CONLEY 08-31-00 B. L. STAFFORD 1-23-02 D. R. JACOBSEN 4-29-02 SERVER84\\00\\dwg REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.
CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.
0 4-29-02 NEW DRAWING PER 01422-015, 01476-010.
LWC BLS DRJ C
O E12-N014 3/4"RHR(53)-2 3/4"RHR(56)-2 PUMP PIT C
O 18"RHR(1)-2-7 3/4"RHR(53)-1-6 FLUSHING OUT CONN.
(M524-2)
FLUSH LINE RHR-2 RHR-4 NOTE 3B NOTE 3A MO 4C MO 21 MO 64C E12-C003 WATER LEG PUMP RHR-V-114 (REF.)
LEGEND:
- 1. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES AND AS NOTED ON DIAGRAM) SUFFIXED WITH A (V)
DENOTE A 3/4" VENT VALVE.
- 2. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.
- 3. ALL VALVES SUFFIXED WITH A (TH)
DENOTE A THROTTLED VALVE.
E12-D001 SEE NOTE 27, M521-1 RHR-V-702C RHR-V-703C RHR-V-246 1
12-29-04 REV PER 02542-302 (D/4, 6-7).
RAK HL SRP