Final Exercise Report Turkey Point Nuclear Power Plant Licensee: Florida Power and Light Exercise Date: February 19,2003 Report Date: May 2,2003 FEDERAL EMERGENCY MANAGEMENT AGENCY REGION ZV 3003 Chamblee-Tucker Road Atlanta, Georgia 30341
TABLE OF CONTENTS Page I. EXECUTIVE suMh4ARy ............................................................................................. 1 I1. INTRODUCTION........................................................................................................... 2 I11. EXERCISE OVERVIEW................................................................................................ 4 A. Pitune EPZ Description ........................................................................................ 3 B. Exercise Participants ............................................................................................ 4 C. Exercise Tunehe ................................................................................................. 5 IV . EXERCISE EVALUATION AND RESULTS ................................................................ 7 A. Summ;uy Results of Exercise Evaluation - Table 2 ............................................... 7 E. Status of Jurisdictions Evaluated .......................................................................... 7 I. STATE OF FLORHDA ........................................................................... 10 1.1 State Emergency Operations Center ............................................ 10 1.2 Forwad State Emergency Response Team.................................. IO 1.3 Emergency News Center ............................................................. 11 1.4 Dose Assessment/Emergenc.y Operations Facility ........................ 11
- 2. RISK JURISDICTIONS......................................................................... 12 2.1 MIAMI-DADE COUNTY .......................................................... 13 2.1.1 Emergency Operations Center ......................................... 13 2.1.2 LP-I Radio Station .......................................................... 14 2.1.3 Protective Actions for Schools......................................... 14 2.1.4 Reception Center ............................................................. 15 2.1.5 Congregate Care ............................................................. 15 2.1.6 Public Access Areas ........................................................ 16 2.1.7 Tr&c Control Points...................................................... B7 2.1.8 Emergency Worker Decontanhation .............................. 17 2.1.9 Medical Service Drill (MS-I) ........................................... 18 I
2.2 MONROE COUNTY ................................................................. 18 2.2.1 Emergency Operations Center ......................................... 18 2.2.2 'Traflic Control Points ...................................................... 20 2.2.3 Ocean Reef Route Nerting .............................................. 20 2.2.4 Emergency Worker Decontankation .............................. 21 2.2.5 Receptionand Congregate Care....................................... 21
- 3.
SUMMARY
OF AREAS REQUIRING CORRECTIVE ACTION .........23 3.1 2003 ARCAs ISSUED ................................................................ 23 3.1.1 66-03-5.a.l-A-01 Risk Jurisdictions................................ 23 3.1.2 66-03-5.a.l-A-02 Miami-Ddc County EOC .................. 24 3.1.3 66-03-5.b.l-A-03 Public Access Areas .......................... 25 3.1.4 66-03-5.a.l-A-04 Monroc County EOC ......................... 25 List of Appendices APPENDIX 1 .ACRONYMS AND hBBREVIATIONS .............................................. 27 APPENDIX 2 .EXERCISE EVALUATORS................................................................ 29 APPENDIX 3 .EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMEN?'.................................................... 31 APPENDIX 4 .EXERCISE SCENARIO...................................................................... 32 List of Tables Table 1 ~
Exercise Timehe ................................................................................................. 6 Table 2 . Summary ofExcrcise Evaluation .......................................................................... 9 ii
I. EXECUTIVE
SUMMARY
On February 19,2003, the Federal Emergency Management Agency (FEMA), Region IV, conducted a partial participation plume exposure pathway exercise in the emergency planning zone (EPZ) around the Turkey Point Nuclear Power Plant. The purpose of the exercise was to assess the level of State and locd preparedness in respondiig to a radiological emergency. This exercise was conducted in accordance with F E W ' Spolicies and guidance concerning the exercise of State and local radiological emergency response plans and procedures.
The previous exercise at this site was conducted on February 21,2001. The qualifymg emergency preparedness exercise was conducted on February 10, 11 and 12,1982.
FEMA wishes to acknowledge the efforts of the many individuals who participated in this exercise. The State of Florida, Risk Counties of hfiabni-Dade and hlonroe, and the C o r n u & of Ocean Reef participated in the Turkey Point Exercise. Protecting the public health and safety is the full-time job of some ofthe exercise participants and an assigned respomibity for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. Cooperation and teamwork ofall the participants were evident during this exercise.
The State and local organizations, except where noted, demonstrated knowledge of their emergency response plans and procedures and adequately implemented them. No Deficiencies were identified duriig this exercise; however, there were four Areas Requiring Corrective Action (ARCA) identified during this exercise. One ARCA regarded the t h e h e s s of activation of the public alert and notifcation system. Two ARCAs concerned the fact that the initial EAS messages did not include the minimum infornlation specified in the September 12,2001 Federal Register Notice. 'The fourth ARCA was issued to Miami-Dade due to the signage in some of the parksin the County.
1
Ir. INTRODUCTION On December 7, 1979, the President directed FEMA to assume the lead responsibility for all of&ite nuclear planning and response. FEMA's activities are conducted pursuant to 43 Code of Federal Regulations (CFR) Parts 350,451 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 11979.
FEMA Rule 44 CFR 350 establishes the policies and procedures for FEhaA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation in joint exercises with licemees.
FEMA's responsibilities in radiological emergency pla.nning for fixed nuclea facilities include the following:
. Takiig the lead in offsite emergency planning and in the review and evaluation of radiological emergency response plans (RERP) and procedures developed by State and local governnrents;
. Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments;
- Responding to requests by the NRC pursuant to the Memorandum of Understanding ktween the NRC and FEMA (Federal Register, Vu%. 58, No. 176.
Septeniber 14, 1993).
. Coordinating the activities of Federal agencies with responsibities in the radiological emergency planning process:
- Department of Commerce
- Nuclear Regulatory Commission
~ Environmental Protection Agency
- Department of Energy
- Department of Health and Human Services
- Depabtment of Transportation
~ Department of Agriculture Department of the Interior, and
- U.S. Food and Drug Administration Representatives of these agencies serve on the FEMA Region IV Regional Assistance Cornmittee (RAC) which is chaired by FEMA.
2
Fornd submission of the REWs for the Turkey Point Nuclear Power Plant to F E W Region It was acconiplished by the Sfate o f Florida on August 26, 1983. Formal approval of these E R P s was granted by FEMA on February 15, 1984, under 44 CFR 350.
A partial participation plume exposure pathway exercise was conducted on February 19, 2003, by FEMA Region IV to assess the capabilities ofstate and local emergency preparedness organizations in implementing their REWs and procedures to protect the public health and safety during a radiological emergency involving the Turkey Point Nuclear Power Plant. The purpose ofthis report is to present the exercise results and
&dings on the performance ofthe offsite response organizations (ORO) during a simulated radiological emergency.
The findings presented are based on the evaluations o f the Federal evaluator team, with h a 1 determinations being made by the Chief Evaluator aid the CO-RACChairperson, and approved by the Regional Director.
The criteria utilized in the FEMA evaluation process are contained in:
B NerREG-0654/FiEM-IEP-l, Rev. 1, Criteria for Preparation and E~aluationof Radiological Emergency Response Plans and Preparedness in S~ppoitof Nuclear Power Plants, November 1980; e FEMA- Areas of Evaluation Methodology, April 25, 2009, Section 111 ofthis report, entitled Exercise Overview, presents basic information and data relevant to the exercise. This section ofthe report contains a description ofthe plume pathway EPZ, a listing of all participating jurisdictions and functional entities which were evaluated, and a tabular presentation o f the time of actual occurrence of key exercise events and activities.
Section IV of this report, entitled Exercise Evaluation and Results, presents detailed inforination on the demonstration of applicable exercise criteria at each jurisdiction or functional entity evahated in a jwisdiction-based, issues-ody format. This section also contains: (1) descriptions of all Deficiencies and .ARCAS assessed during this exercise, recommended corrective actions, and the State and local governments response, and (2) descriptions of ARCAs assessed during previous exercises and the status of the OROs efforts to resolve them 3
111. EXERCISE OVERVIEW Contrained in this section are data and basic information relevant to the February 19, 2003 exercise to test the offsite emergency response capabilities in the area surrounding the Turkey Point Nuclear Power Plant.
A. Plume EPZ Description The Turkey Point Nuclear Power Plant is owned and operated by Florida Power and Light Compcany(FP&L). The plant is located in south Florida, southeast of the City of Homestead in Miami-Dade County. Parts of Miami-Dade and Monroe Counties be within the 10-mile EPZ.
The I O - d e EPZ population is approximately 140,000 residents, mainly north and northwest of the plant. A s d portion of Monroe County is included in the EPZ and includes the private resort community known as Ocean Reef, which is an exception area and has primary notification by route alerting. The land use of the EPZ consists mainly of agricultural and light industrial use. Portions of the cities of Homestead and Florida City are within the 10-mile EPZ. In addition, the Homestead Motorsports Complex and numerous public parks and recreational areas along the coast are within the lO-milc EPZ.
B. Exercise Participants The following agencies, organizations. and units ofgovement participated in the Turkey Point Nuclear Power Plant exercise on February 19,2003.
STATE OF FLORIDA Division of Emergency Management Department of Transportation Department of Public Safety Department of Health, Bureau of Radiation Control RISK JURISDICTIONS Miami-Dade County Monroe County PRIVATENOLUNTEER ORGANIZATIONS American Red Cross Key Largo Volunteer Fire Department Tavernier Volunteer Fke Department Mercy IIospital 4
C. Exercise Tirneline Table 1, on the following page, presents the time at which key events and activities occurred during the Turkey Point Nuclear Power Plait exercise on February 19, 2003.
5
Table 1. Exercise Timeline
)ATE AND SITE: Febru SEOC IF-SERTI DOSE 1 ENC I MIAMI-DADE COUNTY MONROE COUNTY 0906 0947 Ill2
..... i".I...-...--., 1220 jimulntrd Rad. Rclcare StlPted jimulated Had. Relcnse Termlaated Oseiliw Drel~rcdOmrrtional
)erlsration oCStrte of Emergency 1112 7xcscise Terminated Gsriv Preeautioaerv A C ~ ~ O R B :
Stay Tuned Message Close Parlts within 2 mile EPZ I 09J9 1049 Relocate S p i n 1 Needs Population 1st Protective Action Decision:
1st Siren mnvunon:
Ocean ReefRmIe Alerting 1st EAS Mcnsee lod Protective Action Declsho Slav Tuned, Lnd Siren ActivaHon Ocean Reef Route Aicning
!nd EAS MCIIWEIStay Tuned 9rd Protective Action Decision EvacusteZanea: Zmilcradiusand 1,1,3,%4 Shclter Zones: 6 , 7 , 8 & 9
%*Sir@sActivation I" EAS Messier KI Administratian Drelsion: URC Slate workers to Ingest
IV. EXERCISE EVALUATION AND RESULTS Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities, which participated in the February 19,2003, exercise to test the offsite emergency response capabities of State and local govenunents in the 10-mile EPZ around the Turkey Point Nuclear Power Phit.
Each jurisdiction and functionai entity was evaluated on the basis of its demonstration of criteria delineated in exercise criteria contained in Evaluation Area hlethodologyy,dated April 25,2002. Detailed information on the exercise criteria and the extent-of-play agreement used in this exercise are found in Appendix 3 ofthis report.
A. Summary Results of Exercise Evaluation - Table 2 The matrix in Table 2, presents the status of all criteria scheduled for demonstration during this exercise, by all participating jurisdictions and functional entities. Exercise criterion is listed by number. The demonstration status ofthose criteria is indicated by the use of the following letters:
M - Mct (No Deficiency or ARCAs assessed and no unresolved ARC&
fiom prior exercises)
D - Deficiency assessed A ARCA(s) a s d or unresolved ARCA(s) fiom prior exercise(s)
M - Not Demonstrated (Reason explained in Subsection B)
B. Status of Jurisdictions Evaluated
?lais subsection provides information on the evaluation of each participatingjuridiction and functional entity, in ajurisdiction based, issues ody format. Presented below is a definition ofthe term used in this subsection relative to objective demonstration status.
. Met - Lisjting ofthe demonstrated exerciw criterion under whieh no Deficiencies or ARCAs were assessed during this exercise and under which no ARCAs assessed during prior exercises remain unresolve4i.
. Deficiency - Listing of the demonstrated exercise criterion under which one or more Deficiencies was assesed during this exercise. Included is a description of each Deficiency and recommended corrective actions.
. Area Requiring Corrective Actions - Listing ofthe demonstrated exercise criterion under which one or more ARCAs were assessed during the current exercise or ARC& assessed during prior exercks that remain unresolved.
7
Included is a description of the ARCAS assessed during this exercise and the recommermded corrective action to be demonstrated before or during the next biennial exerciw.
. Not Demonstrated - Listing of the exercise criterion not demor&rated as scheduled during this exercise and the reason they were not denionstrated.
. Prior ARCAs Resobed - Descriptions of ARCAS assessed during previous
~
exercises which were resolved in this exercise and the corrective actions demonstrated.
. Prior ARGAS - Unresolved - Descriptions of ARCASassessed during prior exercises wlmich were not resolved in this exerck. Included is the reason the ARCA remains m s o l v e d and recommended corrective actions to be demonstrated before or during the next biennial exercise.
The following are defitions ofthe two typa of exercise issues, which could be discussed in this report.
. A Deficiency is defined in FEMA-REP-14 as "...anobsen.ed or identified inadequacy oforganizationaljmformance in an exercise that could cause a finding that ofbite emergency preparednesy is not adequate to provide reawnable assurance h t appropriite protective nieasures can be taken in the event of a radiological emergency to protect the health md safety of the public living in the viciity of a nuclear power plant."
. An ARCA is dehed in FEMrZ-REP-14as "...an observed or identified inadequacy of organizational performance in an exercise that k not considered, by itself, to adversely impact public health and safety."
8
TABLE 2. Summary of Exercise Evaluation I
DATE AND SITE: February 19,2003 Turkey Point Nuclear Power Plant
- 1. STATE OF FLQRTDA 1.1 State Emergency Operations Center The State Emergency Operations Center (SEOC) was efficiently mobilized and staffed hy over 50-personnel fiom essential State Emergency Support Function (ESF) agencies. It was declared operational at 1010 hours0.0117 days <br />0.281 hours <br />0.00167 weeks <br />3.84305e-4 months <br />. The comtrmunications systems supporting the SEOC contain a n u d e r ofredmdant multi-mode networks to establish and maintain contact with Local, State, Federal, IJtility, and private entities. The SEOC has a state-of-the-art computer message system, which the cadre effectivcly utilized to receive, assign, process, and report completion of work assignments. Direction and control of the exercise was professionalIy managed. The SEOC gave direction and control authority to the Forward State Emergency Response Team (F-SERT) at 1220. The Governor signed the Executive Order, declaring an emergency, at 1303 hours0.0151 days <br />0.362 hours <br />0.00215 weeks <br />4.957915e-4 months <br />. Support of the enicrgency response by the SEOC staff continued until termination of the exercise.
- a. M E T CriteriaI.a.l,l.c.l,l.d.landl.e.l
- h. DEFICIENCY: NONE C. AREAS REQUIRlhG CORRECTIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS-RESOLVED: NONE PRIOR ARCAS UNRESOLVED: NONE 1.2 Forward State Emergency Response Team The F-SERT simulated deployment to the operational area and arrived at the Emergency Operations Facility (EOF) at 1100. Personnel rapidly established communications links and coordinated with FP&L, Miami-Dade and Monroe County reprcsentatives. The team leader conducted a conference caU with the SEOC and the Counties and advised all that they woukd take net control at 1220. F-SERT members were proactive and demonstrated a high degree ofprofessionalism.
- a. M E T Cn~e~l.al,I.b.l,I.c.I,I.d.l,I.e.l,2.a.l,2.b.l,2.b.2,3.al,3.b.land 5.b.l.
- b. DEFICIENCY: NONE
- c. AREAS REQMURG CORRECTIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE 10
- e. PRIOR ARCAS - RESOLVED: NONE 1.3 Emergency News Center The Emergency News Center JENC) was located in the FPBZL corporate ofices. The media wcre lead though a secured stairwcU to the second floor briekg room. The ENC had two hctions: provide infomation to the media and to develop emergency alert system ( E M ) messages. Tlx process for EAS message development and approval provcd c m k m o m e . Three media briefings were conducted. Spokespersons for the State and Counties accurately relayed idormation and intentions to the media.
- a. MET: CritrriaI.a.l,I.h.l,l.d.l,I.c.l~~S.h.l.
- b. DEFKCBENCY: NONE 6 AREAS REQUI%PBNG@BF%RECTWE ACTION: NOW.
- 8. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS RESOLVED: NONE
~
1.4 Dose AssessmentlEnaergewcy Operations Fasility The utility operator's EOF is an exceUent facility kom which all participating response organizations can effectively manage ongoing emcrgcncy operations. Communication, coordination and the flow oftechnical information Retwreen the utility operator and the applicable State and local government oficiak were outstanding. The State staff performed independent accident analyses, to include radiological dose assessment; provided direction a d control for the State radiological field monitoring teams (not evaluated), and developed appropriate protective actions consistent with the preservation of public health and safety. N1 State and local government oScials deployed to the EOF were well trained, followed applicable procedures, and perfonned their respective rcspomibilities profcssiomlly and eEcicntly.
- a. MET Chite~iaI.b.I,i.d.l,i.e.l,2.a.l,2.b.1and2.b.2.
- b. DEFICIENCY: NONE il AREAS REQUIRING CORRECTIVE ACTION: NONE 11
- d. NOT DEMONSTRATED: NONE
- e. PRKOR ARCAS- RESOLVED: NOKE
- f. PRIOR ARCAS- UNRESOLVED: NONE
- 2. RISK JURISDICTIONS The following ARCA is being assessed as a joint ARCA between Miami-Dade and Monroe Counties because a systemic problem concerning the timeliness of the public alcrt and notification (A&N) system existed.
Issue No.: 66-03-5.a.l-A-01 Condition: The activities associated with the alert and notification (A&N) of the pubk were not timely. The fist alert and notiticattion sequence took 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 13 minutes &om the time ofthe emergency classification level (ECL) notification by the utility to the activation ofthe sirens and the broadcast of the emergency alert system (EAS) message. The second A&N sequence took 58 minutes. The third A&N sequence, the protective action sequence, took 38 nlinutes from the time of the decision to the activation of the sirens and the broadcast of the EAS message. Mimu-Dade and Monroe Counties were responsible for all activities related to the A&N sequences and for the activation of the sirens and the broadcast of the EAS message.
The undue delay with the alerting decision and EAS message reviewing procedures resulted in untimely notification of the public.
Possible Cause: The current procedures for EAS message development and approval were cumbersome and caused substantia1 delays in the A&N sequences.
The procedures demonstrated had the County staff in the ENC workroom develop the EAS message and email them to the EOF, where an individual would carry them around to the various representatives for approval. M e r they were approved, the messages were faxed to the media outlets and sent back down to the workroom Once received back in the workroom, the County representative called the EOC to have them activate the siren system. The approval process for the protective action decision EAS message took so long that the Media briefng concerning the protective actions took place slightly before the A&N sequence.
Reference:
NUREG-0654, E.5; Annex A FI, CEMP [Ch. 3, Para II.A;] [Ch. 5, Para MI;] Ch. 7, Para III, and Appendix II Turkey Point Site Plan - Paca 111, V.
and VI.
12
Effect: The delay in informing the public ofthe emergency situation and actions to take could have resulted in unnecessary exposure and erosion of public confidence.
Recommendation: Review and revise A&N procedures to e~isurethat the approval process is timely ji.e. t h e limits are set to ensure rapid approval and prompt activation ofthe A&X system) and that County government maintains control ofall aspects of public alert and notification.
Schedule oFCorrecthe Actions: To br: corrected prior to the ne.xt regularly scheduled Turkey Point exercise in 2005.
2.1 MIAMI-DADE COUNTY 2 A I Emergency Operations Center The Assistant Director and the Operations Chief involved a competent and professional staff in the precautionary relocation of schools, evacuation, sheltering in place of the public and initiating back up route alerting when necessary. The modem emergency Operations Center (EOC) and state-of-the-art electronic equipment supported this successhl emergency response operation. 'Ihc issuance of EAS messages and their content need better coordination and timeliness.
- a. MET: CriteriaI.a,l,l.b.1,l.c.l,i.d.l,l.e.l,2.a.l,2.b.l,2.b.2,2.c.l,3.a.l,3.b.l, 3a.1,and5.b.l.
- b. DEFHCEGNCY: NONE
- 6. AREAS TPEQUEtHaHNG CORRECTIVE ACTION:
hsue No.: 66-03-5.a.1-12-02 Condition: The Miami-Dade County Q5ce of Emergency Management (OEM)
EAS Message #1 did not provide identification ofthe government organization and oflicial with the authority for providing the alert signal and instructional message.
Possible Cause: The information may not have been included in the message because it was assunled that the use ofMimni-Dade letterhead was sufficicnt identification.
Reference:
Revised Guidance, dated September 12,2001.
13
Effect: Without a clear statement as to who is issuing the message, the pubbe could be confused because they would not he sure of the validity to the information.
Recommendation: Review and revise messages to ensure t h t they contain the minimum information required in the September 12, Federal Register notice on Emergency Alert System Messages.
Schedule of Corrective Actions: To he corrected prior to the next regularly scheduled Turkey Point exercise in 2005.
- a. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS- RESOLVED: NONE t PRIOR ARCAS- UNRESOLVED: NONE 2.1.2 LP-1 Radio Station Radio Station WIOD (610 AM) was designated as the LP-1 Radio Station to be evaluated during this exercise. Discussions were held with the editors (one 6.om each shift) on duty regarding the procedure for receiving and processing an EAS message. Both indiduals were fully aware ofthe proper procedure and importance of the message and its contents.
One message was faxed to the radio station as a test during the exercise where it was properly received and processed.
- a. MET: Criterion 5.a.l.
- b. DEFICIENCY: NONE c AREAS REQUXRING CORRECTIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS RESOLVED: NONE
~
- f. -
PRIOR ARCAS UNRESOLVED: NONE 2.1.3 Protective Actions for Schools On January 16,2003, joint interviews were conducted at the Mimi-Dade EQC with the Safety Manager and Prineipddhsktmt Principals for clcven of the public schools within the 1O-mile EPZ. Plans and procedures are in place for relocating and/or sheltering students in place ifrelocation is not an option. Individuals charged with the 14
responsibiiities for executing plans and procedures were knowledgeable, conscientious and should be commended for doing an excellent job.
- a. M E T Criterion 3.c.2.
- b. DEFICIENCY: NONE
- 62. AREAS REQUWWC: CORRECTIVE ACTION: NONE d, NQT DEMONSTRATED: NONE
- e. PRIOR ARCAs - W,SOLVED: NONE 2.1.4 Reception Center Pasomel &om Miami-Dade Fire and Rescue provided an excellent denionstration of evacuee monitoring, decontamination and registration. Tamismi Park is a large facility providing space for all required activities. All personnel were knowledgeable of dose h i t s for turn hack d o r call in. The registration process is done initiatly by Corrections Officers, foiiowed by shelter registration by American Red Cross (ARC) volunteers.
Evacuees would, ifneccssany, l x re-located from the in-processing facility to other shelters for as long as required.
- a. MET: Criteria 3.a.1,6.a4 and 6.c.l.
- b. DEFICIENCY: NONE
- e. AREAS REQUrrzn\rG CORRECTIVE ACTION NONE
- a. NOT DEMONSTRATED: NONE
- e. -
PRIOR ARCAS RESOLVED: NONE t PRIOR ARCAS- UNRESOLVED: NONE 2.1.5 Congregate Care The congregate care facilities are located in a number of the County's public schools.
Specific shelters reviewed for this evaluation were: Felix Varela, Miami Sunset and Miami Coral Park Senior High Schools, and W. R. Thomas and Dora1 Middle Schools.
Fersomel fkom the ARC organize and staff the facilities and use volunteers as the primary source o f m p o w e r . The facilities were well equipped. Sufficient space and ancillary hnctiootls such as the kitchen area and sanitary facilities arc available to support the 15
expected nunikr of evacuees for each school. Personnel demonstrated an excellent knowledge of their requirements and duties.
- a. MET: Criterion 6.c.l
- b. DEFICLENCY: NONE c AREAS REQUIRING COWETKVE ACTION NONE
- d. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS - RESOLVED: NONE
- f. PRIOR ARCAS - UNRESOLVED: NONE 2.1.6 Public Access Areas The evaluator visited 21 of 50 listed public parks. Nine parks were visited in the City of Homestead. Of those nine, three ( h g e l o Mistrebta, Blakey and Ruby George) had no sign$ posted, and one, (Musslewhite Park) had no signs in Spanish. Of the 12 parks visited in Miami-Dade County, one (Seminole Wayside) had no signs, one (Homestcad Bayfiont) did not have Spanish on all the signs and one (Modello Wayside) did not have Spanish signs. The remainder of the parks visited had both English and Spanish signs, which were clearly legible. All of the major parks where the nmjority of the transient population would be expected to gather were well posted.
- a. MET: Criterion NONE
- b. DEFICIENCY. NONE c AREAS REQUnZLYG CORRECTIVE ACTION:
Issue No.: 66-03-5.b.1-A-83 Condition: Of the parks visited in the City of Homestead, Florida three (Angel0 Mistrctta, Blakey and Ruby George) did not have any warning signs posted for the transient population. Additionally, Musslewhite Park had no Spanish signs posted.
The parks visited in Miami-Dade County had the following results: one park (Seminole Wayside) had no signs, one (Homestead Bayfiont) had no Spanish on some signs and one (Modello Wayside) had no Spanish signs.
Possible Cause: Signs were not posted or were possibly missing due to vandaliim.
16
Reference:
Appendix I1 Turkey Point Site Plan - Para VII1.A. and NUKEC-0654 E.7.
Effect: This could res& in confusion to transients during any siren sounding and evacuation.
WeeaemmewdiPtionn: Assure adequate signage is posted and reviewed on a routine basis.
Schedule of Cor~~tHve Actions: To be corrected prior to the next regularly schcduled Turkey Point exercise in 2005.
- d. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS- RESOLVED: NONE
- 8. PRIOR ARCAS UNRESOLVED: NONE s
2.8.7 Traffic Control Points The officers intemiewed were weU aware of their roles and responsibilities and how to request additional equipment, Thc standard process to request special equipment assistance for impediments to traffic flow was also discussed. The officers were very knowledgeable of the use, limits and recording of dosimetry cquipmnent, and to turn in the dosimetxy and c o n t r ~sheets l at end of shift. The oficers understood their respn'ililities, followed their instructions, provided correct information, were professional and displayed a positive attitude.
- a. M E T Criteria3.al,3.6.1 and 3.d.2.
- b. DEFHCHENCY: WQNE 2.1.8 Emergency Worker Decontamination Mimi-Dade Fire and Rescue staff eiyectively densonstrated monitoring and decontamination of emergency worker vcMclcs. Emergency workers demonstrated this activity using required personal protective equipment (WE), as well as decontamination 17
and monitoring equipment. CDV-700 pancake probes were used for effective monitoring of vehicles. Individuals should be commended for their perfonmce and teamwork.
- a. MET: Criteria3.a176.al and 6.b.l.
- b. DEFICIENCY NOhTE
- c. AREAS REQUIRING CORRECTIVE ACTION. NONE
- d. NOT DEMONSTRATED: Noh%
- e. PRIOR ARCAS- RESOLVED: NONE t PRIOR ARCAS-UNRESOLVED: NONE 2.1.9 Medical Service Drill (MS-1)
A medical service drii was held on November 11,2002 at Mercy Hospital. The paramedic and Emergency Medical Tcchnick (EMT) were from Miami-Dade FirdRescue, wore appropriate PPE and had dosimetry. The hospital and emergency room were prepared for the patient. Appropriate dosimetry readings were tdcn and recorded and masures were taken for the prevention of cross contamination both with the ambulance and crew and within the hospital emergency room Nt personnel performed their duties well and teamwork was evident. Exit procedures were demonstrated in an efficient and professional manner with s td inside the hot zone helping those exitciting where necessary.
- a. MET: Criteria 3.al and 6.d. 1.
- b. DEFICIENCY: NONE
- e. AREAS REQUWNG CORRECTIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE
- e. -
PRIOR ARCAS RESOLVED: NONE E PRIOR ARCAS - UNRESOLVED: NONE 2.2 MONROE COUNTY 2.2.1 Emergency Operations Center The Operations Chief effectively managed the EOC. Frequent briekgs and updates were held throughout the exercise. Key agency leaders participated in the excrcise at the EOC I8
and via telephone from the EOF. The Emergency Management Director discussed protective action reconuncndatioau (PAR) and dccisions with County leadership at the EOF, and with the Emergency Management Blkector at Ihe Miam&DadeEOC. Calls were reccivcd by rumor control and rumors were reconciled. The facility was s n d >however, necessary equipment to include communications and supplies were available to support the exercise. Security was providcd by the Key Largo Sheriffs OEce.
- a. MET: CriteriaI.al,i.b.l,l.c.l,l.d.l,1.e.~,2.a.l,2.b.l,2.b,2,2.~.1,3.a.1,3.b.l, 3.c.l,5.a.3and5.b.l.
Issue No.: 6643-5.a.l-A-04 Condition: The Monroe C h n t y Emergency Management E M Message # 1 did not provide:
- 1. Authority issuing the message.
- 2. A sbatcnient that an emergency exists at the plant.
- 3. Reference to Radiological Eniergency Preparedness specific emergency information fe.g. brochurcs and information in telcphonc books) for use by the public during an emergency.
- 4. A closing statement to stay tuned for additional information or that the population tune to another station for additional infonilation.
Possiibk Cause: The infornnation m y not have k e n included in the message because it was assumed that the public was in no immediate danger and Monroc County was identified in the message.
Reference:
Revised Guidance dated September 12,2001.
Efkt: Without a clear statement as to who is issuing the message, reference material and stay tuned messages, the public could be c o f i s c d because they would not be sure ofthe validity to the information.
Recommendation: Review and revise all messages to insure that they contain the minimum infarmtion required in the September 12, Federal Register notice on Ernergency Ncrt System Messages.
Schedule of Corrective Actions: 'To be corrected prior to the next regulahly scheduled Turkey Point exercise in 2005.
(8. NOT DEMONSTRATED NONE 19
- e. PRIOR ARCAS RESOLVED: NONE
~
- f. -
PRIOR ARCAS UNRESOLVED: NONE 2.2.2 Traffic Control Points The County Sheriffs Deputy successfully demonstrated traffic control points (TCP) during an interview. The Deputy was knowledgeable orthe duties and requirements of traitic control including the standard process to request equipment (tow-truck, wrecker or other special equipment) assistance to vehicles that break down or other impediments to traffic flow. The Deputy was howledgeablc of dosimctry use, limits, rccordiig methods, and end of shill turn in requirements. The Deputy understood the responsibilities, provided correct idormation, was professional and displayed a positive attitude.
- a. MET: Criteria 3.a.1, 3.d. I and 3.d.2.
- b. DEFICIENCY: NONE c AREAS REQL~IRUVGCORRECTIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE
- e. PRIOR ARCAS - RESOLVEI): NONE E PRIOR ARCAs - UNRESOLVED: NONE 2.2.3 Ocean Reef Route Alerting At 1145, Public Safety personnel were dispatched to conduct route alerting in mnes 9 through 14. The Public Safety Oficer drove through each ofthe six zones and simulated reading a pre-scripted message over the vehicles public address system alerting the residents to a S a at Turkey Point and instructkg them to monitor their radio or the Ocean Reef Community television station. The Public Safety Officer was equipped with doshetry, thermoluminescent dosimetry (TLD) and potassium iodine (KI). He demonstrated knowledge of his dosimetry and the record keeping requirements, for his dosimeter and K1. The oficer was hiowledgeable of check tinies, call-in. and turn back values for the self-reading dosimeters.
- a. MET: Criteria 1.d. 1, l.e.l>3.a.l and 5.a.3.
- b. DEFICIENCY: NONE C. AREAS REQUIRING CORRECTIVE ACXION: NONE 20
- d. NOT DEMONSTRATED: NONE 23.4 Emergency Worker Decontamination Key Largo Volunteer Fire Department and TavemKr Volunteer Fire and Rescue staffs eBeetivdy demonstrated nionitoring and decontamination of emergency workers atid theu vehicles. Conamand and control was excellent with no clarification needed when directions were given. Emergency workers demonstrated this activity using required WE, as well as appropriate decontamination and monitoring equipment. CDV-700 pancake probes were used for effective monitoring of vehicles. Personnel interviewed were knowledgeable oFKI; how it would be issued, and how to complete the required documentation. Participants should be cornnxmdcd for their performance and teamwork.
a, MER Criteria 3.al,6.al and 6.b.l.
- b. DEFICIENCY: NONE c AREAS REQUIRING CBB%PR@@TIVE ACTION: NONE
- d. NOT DEMONSTRATED: NONE 2 3 - 5 Reception anel Congregate Care Reception and congregate care activities were demonstrated at Key Largo Elementary School. Fire and ambulance persoimd from the Key Largo Volunteer F i e Department demonstrated monitoring and decodan&ation of evacuees and the ARC was on hand to register evacuees and manage congregate care functions. Emergency workers demonstrated proper monitoring techniques and knowledge oftheir dosimetry, and KI.
ARC personnel had all equipment necessary to register and shelter evacuees. All personnel participating in the exercise were howledgeable of md enthusiastic about their roles and respomikdities.
- a. MET: Criteria 3.a.l,6.al and 6.c.l
- b. DEFBCENCY: NONE 21
P. AREAS REQUIHING CORRECTIVE ACTION NONE
- d. NOT DEMORSTHATED: NONE
- e. PRIOR ARCAS RESOLVED: NONE
~
- f. -
PRIQR ARGAS UNRESOLVED: NONE 22
- 3.
SUMMARY
OF AREAS REQUEUNG CORRECTIVE ACTION 3.1 2003 ARCAs ISSUED 3.1.1 66-03-5.a.l-A41 Condition: The activities associated with the alert RiskJurisdictions and not&atkn(A&N) ofthc public were not timely. The first alert and notification sequence took 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 113 minutes from the time of the emergency classification level notification (ECL) by the utility to the activation of the sirens and the broadcast of the emergency alert system (EAS) message. The second A&N sequence took 58 minutes. The third A&N sequence, the protective action sequence, took 38 minutes ffom the time of the decision to the activation of the sirens and the broadcast of the EAS message. Miami-Dade and Monroe Counties were responsible for all activities related to the A&N sequences and for the activation of the sirens and the broadcast of the EAS message.
The undue delay udh the alerting decision and EAS message reviewing procedures resulted in untimely notification of thc public.
Possible Cause: The current procedures for EAS message development and approval were cumbersome and caused substantial delays in the A&N sequences. The procedures demonstrated had the County staff in the ENC workroom develop the EAS message and email them to the EOF, where an individual would cany them around to the various representatives for approval. M e r they were approved, the messages were faxed to the media outlets and sent back down to the workroom. Once received back in the workroom, the County representative called the EOC to h v e them activate the siren system. The approval process for the protective action decision EAS message took so long that the Media briefing concerning the protective actions took place slightly before the A&N sequence.
Reference:
NUKEG-0654, E.5; Annex A FL CEMP
[Ch. 3, Para 1 1 4 [Ch. 5, Para III;] Ch. 7, Para 111, 23
and Appendix I1 Turkey Point Site Plan - Para 111,
- v. and VI.
Effect: The delay in informing the public ofthe emergency situation and ac?ionsto take could have resulted in unnecessary exposme and erosion of public confidence.
Wecommendation: Review and revise A&N procedures to emure that the approval process k timely (i.e. time limits are set to ensure rapid approval and prompt activation ofthe A&N system) and that County government inaintains control of all aspects of public alert and notification.
Schedule of Corrective Actions: To be corrected prior to the next regularly scheduled Turkey Point exercise in 2005.
3.12 66-03-5.a.l-A-03 Condition: The Miami-Dade County Ofice of Miami Dade Co~ntyEmcrgency Mamgement (OEM) EAS EOC Message #1 did not provide identificationofthe government organization and official with the authority or pro~idiigthe alert signal and instructional message.
Possible Cause: The information may not have been included in the message because it was assumed that the use of Miami-Dade letterhead was sufficient identification.
Reference:
Revised Guidance, dated September 12, 2001.
EEe& Withunt a clear statement as to who is issuing the message, the public could be confused because they woukl not be sure ofthe validity to the Xormhn.
Recommendation: Review and revise messages to ensure that they contain the minimum information required in the Septemkr 12, Federal Register notice on Emergency Alert System Messages.
24
Schedule of Corrective Actions: To be corrected prior to the next regularly scheduled Turkey Point exercise in 2005.
3.1.3 66-03-5.b.l-A43 Condition: Of the parks visited in the S i of Public Access Areas Homestead, Florida three (Angeko Mistrettq Blakey and Ruby George) did not have any warning signs posted for the transient population. Additionally, Musslewhite Park had no Spanish signs posted. The parks visited in Miami-Dade County had the following results: one park (Seminole Wayside) had no signs, one (Homestead Bayfront) had no Spanish on some signs and one (Modello Wayside) had no Spanish signs.
Possible Cause: Signs were not posted or were possibly missing due to vandalism.
Reference:
Appendix I1 Turkey Point Site Plan -
Para V1II.A. and NUREG-0654 E.7.
Effect: This could result in confusion to transients during any siren sounding and evacuzztiotion.
Recommendation: Assure adequate signage is posted and reviewed on a routine basis.
Schedule oZCorrective Actions: To be corrected prior to the next regularly scheduled Turkey Point exercise in 2005.
3.1.4 66-03-5.a.t-A-04 Condition: The Monroe County Emergency Monroe County Management EM Message # 1 did not provide:
- 1. Authority issuing the message.
- 2. A statement that an emergency exists at the plant.
- 3. Reference to Radiological Emergency Preparedness spec&
emergency information (e.g.
brochures and inhrmation in telephone books) for use by the public during an emergency.
- 4. A dosing statement to stay tuned for 25
additional information or that the population tune to another station for additional uliormation.
Possible Cause: The information may not have been included in the message kecause it was assumed that the public was in no immediate danger and Monroe County was identified in the message.
Reference:
Revised Guidance dated September 12, 2001.
Effect: Without il clear statement as to who is issuing the message, reference material and stay tuned mnssages, the public could be confused because they would not be sure of the validity to the Xormtion.
Weeommendatiow: Review and revise all mes.sageges to insure that they contain the minimum information required in the September 12, Federal Register notice on Emergency Nert System Messages.
Schedaale of Corrective Actions: 'To be corrected prior to the next regularly scheduled Turkey Foint exercise in 2005.
26
APPENDIX 1 ACRONYMS AND ABBREVIATIONS The following is a list ofthe acronyms and abbreviations, which may have &en used in this report.
A&N Alert and Notification ARC American Red Cross ARCA Area Requiring Corrective Action CFR Code of Federal Regulations DEM Division of Emcrgcncy Managcnient E M Emergency Alert System ECL Emergency Classification I,evel EMT Emergency Material Technician ENC Emergency News Center EOC Emergency Operations Center EOF Emergency Operations Facility EPZ Emergency Planning Zone ESF Emergency Support Function FEW Federal Emergency Management Agency FP&L Florida Power & Light Company F-SERT Forward-State Emergency Respoiisc Team GE General Emergency KI Potassium Iodide NUREG-0654 NUREG-0654,FEM-REF-1, Rev. B WiferiaforPreparation and
~
Evaluation of Rudiologieul Emergency Response Pluns and Prepuredness in Support of Nuclear P o w r Plants. Noveember 1980 OEM Office of Emergency Management OR0 Offsite Response Organization FAD Protective Action Decision PAR Protective Action Recommendation PI0 Public I d o m t i o n Officer PPE Personal Protective Equipment RAC Regional Assistance Committee REP Radiological Emergency Preparedness 27
REW Radiological Einerymcy Response Plan SAF, Site Area Emergency SEOC State Emergency Operations Ceiitcr
'I'CP TraEc Control Point TLD Thermoluminescent Dosinicter 28
APPENDIX 2 EXERCISE EVALUATORS
?'he following is a list ofthe personnel who evaluated the Turkey Point Nuclear Power Plant excrcise on February 19,2003. The organization reprcscntcd by each cvaluator is abbreviatcd below.
EPA ~ Environmental Protection Agency FDA - Food and Drug Administration FEMA - Federal Emergency Management Agency ICF - ICF Consulting. Incorporatcd NRC - Nuclear Regulatory Commission USCG - United States Coast Guard Thonlas E. Reynolds c o - M C chairman EVALUATION SITE EVALUATOR ORGANZATION Chief Evaluator IIelen Wdgus FEMA STATE OF FLORIDA State Emergency Operations Center Henry Chistaimen ICF Forward State Emerg. Response Team Helen Wilgus FEMA Bill 1,arrabee ICF Emergency News Center Lany Robertson FEMA Rosemary Sam..el ICF Dose Assessment/ Robert Trojanowski NRC Emergency Operations Center MIAMI-DADE COUNTY Emergency Operations Center Robert Perdue EM4
'Tom Trout FDA Protective Action for Schools Eddie IIicknlan Reception Center Alejandro Fernandez rcF Roy Smith ICF 29
EVALUATION SITE EVALIJATOR ORGANIZATION Congregate Care Public Access Rick Button EPA LP-1 Radio Station Doug StUtL ICF Emergency Worker Decontamination Eddie HIicknman FEM Roy Smith ICF Traffic Control Points Roy Smith ICF MONROE COUNTY Emergency Operations C:entcr Eddie Nicknm FEW Reception and Congregate Care Joscph Canoles Emergency Worker Decontamination Helen Wdgus FEMA
'Tom Reynolds FEMA Traffic Control Points Helen \.viigus Ocean Reef Route Alerting Joseph Caiiolcs FEMA 30
APPENDIX 3 EXERCISE CRITERIA AND EXTENT-OF-PLAY A6REEMENT Because the exercise criteria are intended for use at all nuclear power plant sites and because of variations among offsite plans and procedures, an extent-of-play agreerncnt is prepared by the State and approved by FEMA to provide evaluators with guidance on expected actual demonstration of the criteria.
A. Exercise Criteria Attached is the specific radiological emergency preparedness criteria scheduled for denionstration during this excrcise.
B. Extent-of-Play Agreement The extent-of-play agreement on the following pages was submitted by the State of Florida and approved by FEMA Region IV in prcparation for the Turkey Point Nuclear Power Plant exercise on February 19,2003.
(Final Report Only) 31
Criterion 1I.a.l: OROs use effective procedures to alert, notify, and mobilize emergency personnel and aetivate facilities in a timely manner. (NUREG-0654,A.4;D.3,4; E.1,2; HA)
Extent of Play Responsible QRQs should demonstrate the capability to receive notification of an emergency situation from the licensee, verify the notification, and contact, alert. and mobilize key emergency personnel in a timely manner. Responsible OROs should demonstrate the activation of facilities for immediate use by mobilized personnel when they amve to begin emergency operations. Activation of facilities should be completed in accordance with the plan and/or procedures. Pre-positioning of emergency personnel is appropriate, in accordance with the extent-of-play agreement, at those facilities located beyond a normal commuting distance from the individuals duty location or residence.
Further, pre-positioning of staff for out-of-sequence demonstrations is appropriate in accordance with the extent-of-play agreement.
All activities must be based on the OROs pians and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: EOC personnel will be pre-positioned. Emergency management stafwith EOF responsibilities will remain at the EOC until the activation of the EOF. Upon activation of the EOF Miami-Dade OEM will deploy appropriate staffta, that facility.
Monroe: Personnel with EOC responsibilities will be pre-notified in and directed to report to the EOC at 8.00AM on the morning of the exercise. Emergency Management staff with EOF responsibilities will assemble in the cafeteria at the FP&L Headquarters Building (where the EQF is located) until activation of the EOF. Monroe County Office of Emergency Management will deploy appropriate staff to that facility. Monroe County staff assigned to the Miami-Miami-Dade EOC will pre-deploy to that facility.
2
~
SEOC: Personnel will be in place by 9:OO Ah4 in anticipation of the notification of a Site Area Emergency.
- F§ERT: Will pre-position at the EOF at approximately 8:30 ANI in anticipation ofthe EOF being declared operational
~
DOWBRC: RRC will pre-position field teams, the mobile laboratow &
the sample prepvehicle, EOF personnel wili arrive within one hour afier the Alert emergency classification declaration. FQ~- training purposes on&
1.b - Facilities:
Criterion 1.b.I: Faciiitks are sufficient to support the emergency response.
(NILJREG-0654, H.3)
Extent of Play Faciiities will only be specifkally evaluated for this criterion if they are new or have substantial changes in structure or mission. Responsible OROs should demonstrate the availability of facilities that support the accomplishment ofcmsrgeency operations. Some of the areas to be considered are: adequate space, furnishings, lighting, restrooms, ventilation, backup power andfor alternate facility (if required to support operations).
Facilities must $e set up based on the 0630s plans and procedures and demonstrated as they would be used in an actual ernergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dede: The Miami-Dade EOC will be fuily activated to demonstrate this objective.
Monroe (Beean Resf): Monroe County EOC will be fully activated to demonstrate this objective.
State (FSERT, DOSEEOF, ENC): in agreement 3
1.c - Direction and Control :
Criterion l.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible (NUREG-0654, A.1.d; A.24 b)
Extent of Play Leadership personnel should demonstrate the ability to carry out essential functions ofthe response effort, for example: keeping the staff informed through periodic briefings andor other means, coordinating with other appropriate OROs, and ensuring completion of requirements and requests All activities associated with direction and control must be performed based on the OROs plans and procedures and completed as they would be in an actuai emergency, unless otherwise noted above or indicated in the extent-of-play agreement.
Miami-Dade: Miami-Dade County QEM will assume control of local operations upon activation ofthe EOC. Local response will be coordinated from the E W .
Protective Action Decisions and county wide emergency response policy determinations will be made at the EQF.
Monroe: Monroe County Oftice of Emergency Management wdl assume control of local operations upon activation ofthe EOC. Local response will be coordinated from the EOC. Protective action decisions and countywide emergency response policy determinations will be made at the EOF.
State (SEOC, FSERT): In Agreement 1.d -Communications Equipment:
Criterion l.d.1: At least two communication systems are availabte, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabiEities are maaaged in support of emergency operations. (NUREG-0654, F.1,2)
Extent of Plav OROs will demonstrate that a primary and at least one backup system are fully functional at the beginning of an exercise. If a communications system or systems are not functional, but exercise performance is not affected, no exercise issue will be assessed.
4
Communications equipment and procedures for facilities and field units should be used as needed for the transmission and receipt of exercise messages. All facilities and field team shoufd have the capability to access at least one communication system that is independent of the commercia1 telephone system. Responsibk OROs should demonstrate the capability to manage the communication systems and ensure that all message traffic is handled without delays that might disrupt the conduct of emergency operations. QROs should ensure that a coordinated communication link for fixed and mobile medical suppoport fafiilities exists. The specific communications capabilities of OROs S ~ Q U be ! ~
commensurate with that specified in the response plan andlor procedures. Exercise scenarios could require the failure o f a communications system and the use of an alternate system, as negotiated in the extent-of-play agreement.
AI1 activities associated with the managemcnt of communications capabilities must be demonstrated based on the OROs plans and procedures and completed as they would be in an actual emergency, unless otherwise noted above or in the extent-of-play agreement.
Miami-Dnde: Hot Ring Down and landline telephone communications will be demonstrated as primary and back-up systems, respectively.
Monroe (Ocean Reef) Hot Ring Down and landline telephone cornmunications will be demonstrated as primary and backup systems, respectively.
State [SESC, FSERT, ENC): In Agreement
- DB)SE/EBF (WWBRC): BRC will use communication equipment as stated in SOP 3.
1.e - Equipment and Supplies to S u p p o ~ Operation:
Criterion 1.d: Equipment, maps, display%dosimetry, potassium iodide (M)* and other S M ~ P are ~ Ssufficient to suppod emergency operations.
(NUREG-0554, H.lf,BO; J.lO.a, b, e?All; K3.s)
Extent of Play Equipment within the facility (facilities) s h ~ u l dbe sufficient and consistent with the role assigned to that facility in the OROs plans andior procedures in support of emergency operations. Use of maps and displays is encouraged.
All instruments, should be inspected, inventoried, and operationaily checked before each u s e Instruments should be calibrated in accordance with the manufacturers recommendations. Unmodified CDV-700 series instruments and other instruments without a manufacturers recommendation should be calibrated annually. Modified 5
CDV-700 instruments should be calibrated in accordance with the recommendation of the modification manufacturer. A label indicating such calibration should be on each instrument or calibrated frequency can be verified by other means. Additionally, instruments being used to measure activity should have a range of readings sticker affixed to the side of the instrument. The above considerations should be included in 4.a.l for field team equipment; 4.c. 1 for radiologkal laboratory equipment (does not apply to anaiytical equipment); reception center and emergency worker facilities equipment under 6.a. 1; and ambulance and medical facilities equipment under 6.d. I Sufficient quantities of appropriate direct-reading and permanent record dosimetry and dosimeter chargers should be available for issuance to all categories of emergency workers that could Re deployed from that facility. Appropriate direct-reading dosimetry should allow individual(s) to read the administrative reporting limits and maximum exposure limits contained in the OROs plans and procedures.
Dosimetry should be inspected for electrical leakage at least annually and replaced, if necessary. CDV-138s, due to their documented history of electrical leakage problems, should be inspected for electrical leakage at least quarterly and replaced if necessary.
This leakage testing wili be verified during the exercise, through documentation submitted in the Annual Letter of Certification, andor through a staff assistance visit.
Responsible OROs should demonstrate the capability to maintain inventories of KI sufficient for use by emergency workers, as indicated on rosters; institutionalized individuals, as indicated in capacity lists for facilities; an4 where stipulated by the plan and/or procedures, members of the general public (including transients) within the plume pathway EIPZ.
Quantities of dosimetry and KI available and storage loeations(s) will be confirmed by physical inspection at storage locationjs) or through documentation of current inventory submitted during the exercise, provided in the Annual Letter of Certification submission, and/or verified during a StaffAssistance Visit. Available supplies of KI should be within the expiration date indicated on KI bottles or blister packs. As an alternative, the OR0 may produce a letter from a certified private or State laboratory indicating that the KI supply remains potent, in accordance with U.S. Pharmacopoeia standards.
At locations where trafic and access control personnel are deployed, appropriate equipment (e.g., vehicles, barriers, traffic cones and signs, etc.) should be available or their availability described.
All activities must be based on the OROs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicatcd in the cxtent-of-play agrement.
Miami-Dade: This equipment will be checked and verified by FEMA during a Site Visit on December 12,2002. Dosimeters will also be checked prior to the exercise.
6
Monroe (Ocean WeeF): Same as Miami-Dade (site visit for Monroe County is scheduled for December 9,2009).
State (SEBC, F§EFtT, ENC): Dosimetry and KI will not be distributed from the SEQC or from the EOF. A discussion on issuance of dosimetry and KI to State Emergency Workers can be provided by the REP Technical Expert at the EOF, if necessary.
- DBSE/EDF (MWBRC): BRC wiil use equipment and supplies as stated in SOPS.
- 2. PROTECTIVE ACTION DECISION MAKING 2.a - Emergency Worker Exposure Control:
Criterion 2.~1.8: ORQs use a decision making process, considering relevant factors and appropriate Coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency W Q ~ C including
~ S provisions to authorize radiation exposure in excess of administrative limits or protective action guides. (NtJIREG-0654,KA9J.IO.e, 0 Extent of Play OROs authorized to send emergency workers into the plume exposure pathway EPZ should demonstrate a capability to meet the criterion based an their emergency plans and procedures.
Responsible OROs should demonstrate the capability tu make decisions concerning the authorization of exposure levels in excess of preauthorized levels and to the number of emergency workers receiving radiation dose above pre-authorized levels.
As appropriate, OROs should demonstrate the capability to make decisions on the distribution and administration ofK1 as a protective measure, based on the ORO's plan and/or procedures or projected thyroid dose compared with the established Protective Action Guides (PAGs) for KI administration.
All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or othenvise indicated in the extent-of-play agreement.
7
Miami-Dade: Use of KI, by Emergency Workers and institutionalized persons, wili he demonstrated through discussion.
Monroe: Use of Kl by Emergency Workers will be demonstrated through discussion.
State (FSERT, DOSEEOF):
~
FSERT: Information relative to State Emergency Worker exposure control will be provided through discussions with the REP Technical Expert in the EOF.
- DOSEEOF (DOWBRC): BRC mill use dosimetry and instrumentation as stared in SOPS. Field operations For trainhgpurpses on&.
2.b- Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency:
Criterion 2.b.l: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data, and licensee and O R 0 dose projections, as we11 as knowledge of onsite and offsite environmental conditions. (N1JRECr0654,I.$,10 and Supplement 3)
Extent of Play During the initial stage of the emergency response, following notification of plant conditions that may warrant offsite protective actions, the O R 0 should demonstrate the capability to use appropriate means, described in the plan and/or procedures, to develop protective action recornmendations (PAR)for decision-makers based on available information and recommendations from the licensee and field monitoring data, if available.
When release and meteorological data are provided by the licensee, the O R 0 also considers these data. The O R 0 should demonstrate a reliable capability to independently validate dose projections. The types of calculations to be demonstrated depend on the data available and the need for assessments to support the PARs appropriate to the scenario. In all cases, calculation of projected dose should be demonstrated. Projected doses should be related to quantities and units ofthe PAG to which they wil! be compared. PARs should be promptly transmitted to decision-makers in a prearranged format.
Differences greater than a factor of 10 between projected doses by the licensee and the O R 0 should he discussed with the licensee with respect to the input data and assumptions used, the use of different modeIs, or other possible reasons. Resolution of thcse 8
differences should be incorporated into the PAR iftimely and appropriate. The O R 0 should deinonstrate the capability to use any additional data to refine projected doses and exposure rates and revise the associated PARS.
All activities must be based on the ORO's plans and procedures and completed as they would he in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement, Miami-Dade: Miami-Bade will demonstrate the coordination of Protective Action Decisions with the SERT, Monroe County, FPL, BRC, and the operations element at the ECX prior to finalizing the implementation of Protective Action Decisions.
Monroe: Monroe County will demonstrate the coordination of Protective Action Decisions with the SERT, Miami-Dade County, FPL, BRC, and the operations element at the EOC prior to finalizing the implementation of Protective Action Decisions.
State (FSERT, DOSEZOF):
FSER'F: In Agreement
- DOSEEOF (DOHWRG): BRC will use the RASCAL dose assessment code as stated in SOPS.
Criterion 2.b.2: A decision-malticing p r ~ ~ involving a s eonsideration of appropriate factors and necessary coordination is used ta, make protective action decisions (PAD) for the general public (incBnding the recommendation for the use of KI, if O R 8 poky). (NUREG-0654, J.9,10.f, rn)
Extant of Play Offsite Response Organizations (UROs) should have the capability to make both initial and subsequent PADS.They should demonstrate the capability to make initial PADS in a timely manner appropriate to the situation, based on notification from the licensee, assessment of plant status and releases, and PARS from the utiiity and OK0 staff.
The dose assessment personnel may provide additional PARS based on the subsequent dose projections, field monitoring data, or information on piant conditions, The decision makers should demonstrate the capability to change protective actions as appropriate based on these projections.
9
If the O R 0 has determined that KI will be used as a protective measure for the general pubiic under offsite plans, then the O R 0 should demonstrate the capability to make decisions on the distribution and administration ofKI as a protective measwe for the general public to supplement sheltering and evacuation. This decision should be based on the ORO's plan and/or procedures or projected thyroid dose compared with the established PAG for KI administration. The K1 decision making process should involve close coordination with appropriate assessment and decision-making staff.
If more than one O R 0 is involved in decision-making, OR& should communicate and coordinate PADS with affected OROs. OROs should demonstrate the capability to communicate the contents of decisions to the affected jurisdictions.
AI1 decision-making activities by OR0 personnel must be performed based on the ORQs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: This objective will be demonstrated through discussions and coordination at the EOF.
Monroe: This objective will be demonstrated at the EOF State (FSERT, DOSEEOF):
~ E'SERT: In Agreement
- DOSEEOF (DOW BRC): BRC will use the RASCAL dose assessment code as stated in SOPS.
2.c -Protective Action Decisions for Protection of Special Populations:
Criterion 2.c.l: Protective action decisions are made, as appropriate, for special population groups. (NZTRF,G-0654, J.9, J.lQ.d, e)
Extent of Play Usually, it is appropriate to implement evacuation in areas where doses are projected to exceed the lower end of the range of PAGs, except for situations where there is a high-risk environment or where high-risk groups (e.g., the immobile or infirm) are involved. In these cases, examples of factors that should be considered are: weather conditions, shelter availability, availability oftransportation assets, risk of evacuation vs. risk from the avoided dose, and precautionary school evacuations. In situations where an institutionalized population cannot be evacuated, the administration of KI should be considered by the OROs.
Applicable QKOs should demonstrate the capability to alert and notify all public school systemsldistricts of emergency conditions that are expected to or may necessitate protective actions for students. Contacts with public school system%districtsmust be act ual.
Bn accordance with plans andor procedures, OROs and/or oficials of public school systemddistricts should demonstrate the capability to make prompt decisions on protective actions for students. Officials should demonstrate that the decision making process for protective actions considers (that is, either accepts automatically or gives heavy weight to) protective action recommendations made by O R 0 personnel, the ECL at which these recommendations are received, prcplanned strategies for protective actions for that ECL, and the location of students at the time (for example, whether the students are still at home, en route 40 the school, OH at the school).
All decision-making activities associated with protective actions, including consideration of available resources, for special population groups must be based on the OROs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Bade: A list of PSN in the EFZ, and procedures for canying out their protection, will be made available for review at the EOC. PSN will not be moved Monroe: There are no PSN in the Monroe County ET%
- 3. PROTECTIVE ACTION IIWPLEIMENTATIBN 3.a - Hmplementation of Emergency Worker Exposure ControS:
Criterion 3.a.l: The QROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergeascy workers periodically and at the end of each mission read their dosirnetem and record the readings on the appropriate exposure record or chart. (NUREG-0654, #3.e, b9 Extent of Play QROs should demonstrate the capability %Qprovide appropriate direct-reading and permanent record dosimetry, dosimeter chargers, and instructions on the use of dosimetry to emergency workers. For evaluation p u p s e s , appropriate direct-reding dosimetry is defined as dosimetry that allows individualjs) to read the administrative reporting limits (that are pre-established at a level low enough to consider subsequent calculation of Total Effective Dose Equivalent) and maximum exposure limits (for those emergency workers involved in life saving activities) contained in the OROs plans and procedures.
11
Each emergency worker should have the basic knowledge of radiation exposure limits as specified in the ORB'S plan andor procedures. Procedures to monitor and record dosimeter readings and to manage radiological exposure control should be demonstrated.
During a plume phase exercise, emergency workers should demonstrate the procedures to be followed when administrative exposure limits and turnback vaEues are reached. The emergency worker should report accumulated exposures during the exercise as indicated in the plans and procedures. ORQs should demonstrate the actions described in the plan and/or procedures by determining whether to replace the worker, to authorize the worker to incur additional exposures or to take other actions. If scenario events do not require emergency workers to seek authorizations for additional exposure, evaluators should interview at least two emergency workers, to determine their knowledge of whom to contact in the event authorization is needed and at what exposure levels. Emergency worken may use any available resources (e.g., written procedures and/or coworkers) in providing responses.
Although it is desirable for all emergency workers to each have a direct-reading dosimeter, there may be situations where team members will be. in close proximity to each other during the entire mission and adequate control of exposure can be eEected for all members ofthe team by one dosimeter worn by the team leader. Emergency workers who are assigned to low exposure rate areas, e.g.,at reception centers, counting laboratories, emergency operations centers, and communications centers, may have individual direct-reading dosimeters or they may be monitored by dosimeters strategfcally placed in the work area. It should be noted that, even in these situations, each team member must still have their own permanent record dosimetry.
Fndividuals without specific radiological response missions, such as farmers for animal care, essential utility service personnel, or other members of the public who must re-enter an evacuated area following or during the plume passage, should be limited to the lowest radiological exposure commensueate with completing their missions.
All activities must be based on the 6RO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: (out ofsequence) Will demonstrate this objective during the emergency wash down drill on January 8,2003 at 9:OO AM at the Tamiami Park Youth Fair Grounds. Emergency workers will receive high and low range dosimeters. This activity can be re-demonstrated during the evaluation, if and when necessary, in order to satisfy the requirements of the criteria.
Monroe: (out ofsequence) This will be demonstrated on February 17 at 6:OO PM at the Key Iargo Fire Department. This activity can be redernconstrated during the evaluation, if and when necessary, in order to satisfy the requirements ofthe criteria.
12
State (FSERT):
- FSERT: Will be accomplished through discussions with the REP Technical Expert in the EOF.
- DOWBRC: BRC will use dosimetry and instnunentation as stated in SOPS. For training purposa only 3.c - Hmp!ementnation of Protective Actions for Special Populations:
Criterion 3.6.1: Protective action decisions are implemented far special populations otber than srhoo~swithin areas subject to protective actions.
(NBJREG-0654, J.IB).e, d, g)
Extent of Play Applicable OROs should demonstrate the capability to alert and notify (for example, provide protective action recommendations and emergency information and instructions) special populations (hospitals, nursing homes, correctional facilities, mobility impaired individuals, transportation dependent, ete.). OROs should demonstrate the capability to provide for the needs of special populations in accordance with the OKOs plans and procedures.
Contact with special populations and reception facilities may be actual or simulated, as agreed to in the Extent ofPiay. Some contacts with transportation providers should be actual, as negotiated in the extent ofplay, All actual and sianuiated contacts should be logged.
All implementing activities associated with protective actions for special populations must be based on the OXOSplans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: A list ofPSN, and a list for caving out their protection, #ill bs available for review at the EOC. PSN will not be moved.
Monroe: There are currently no PSNs in the EPZ in Monroe County.
13
Criterion 3.c.2: OROdSchool officials implement protective actions for schools. (NUREG-0654, J.lO.c, d, g)
Extent of Play Public schooi systems/districts shall demonstrate the ability to implement protective action decisions for students. The demonstration shall be made as follows: At least one school in each affected school system or district, as appropriate, needs to demonstrate the implementation of protective actions. The implementation of canceling the sc.hool day, dismissing early, or sheltering should be simulated by describing to evaluators the procedures that would be followed. If evacuation is the implemented protective action, ail activities to coordinate and complete the evacuation of students to reception centers, congregate care centers, or host schools may actually be demonstrated OK accomplished through an interview process. If accompiished through an interview process, appropriate school personnel including decision making officials (e& superinten$ent/principal, transportation directorbus dispatcher), and at least one bus driver (and the bus drivers escort, if applicable) should be available to demonstrate knowledge of their role(s) in the evacuation of school children. Communications capabilities between school officials and the buses, if required by the plan andor procedures, should be verified.
Officials ofthe school system(s) should demonstrate the capability to deveCop and provide timely information to OROs for use in messages bo parents, the genera! public, and the media on the status of protective actions for schools.
The provisions of this criterion also apply to any private schools, private kindergartens and day care centers that participate in REP exercises pursuant to the OROs plans and procedures as negotiated in the extent-of-play agreement.
All activities must be based on the OROs plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: (out ofsequence) Eleven schools will be intewiewed on January 16,2003, between 9:OO Ah4 and 200 PM. This activity can be re-demonstrated during the evaluation, if and when necessary, in order to satisfy the requirements ofthe criteria.
Monroe: There are no public schools within Monroe countys EPZ.
14
3.d - implementation of Traffic and Access Control.
Criterion XdJ: Appropriate traffic and a~eesscontrol is atablblished.
Accurate instructions are provided to traPPic and access eontrd personnel.
(NUREG-Q654,J . 3 Q j)
Extent of Play ORBS should demonstrate the capability to select, establish, and staff appropriate traffic and access control points, consistent with protective action decisions (for example, evacuating, sheltering, and relocattion), in a timely manner. OROs should demonstrate the capability to provide instructions tu traffic and access control staff on actions to take when modifications in protective action strategies necessitate changes in evacuation patterns or in the area(s) where access is controlled.
Traffic and access control staff should demonstrate accurate knowledge of their roles and responsibilities. This capability may be demonstrated by actual deployment or by interview, in accordance with the extent-of-play agreement.
In instances where ORQs lack authority necessary to control access by certain types of traffic (rail, water, and air traffic), they should demonstrate the capability to contact the State or Federal agencies with authority to control access.
All activities must be based an the OKO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: OM^ o/sequence) Will demQn§tri3tethis objective, in conjunction with the emergency wash down drill on January 8,2003, at 9:OO AM, at %amiami Park, with one officer from the Miami-Dade Police Department. Discussion will take placc in the EQC regarding paragraphs one and three. This activity can be re-demonstrated d&ng the ma8uabion, iJfand when ~ecessary,in order to mfisfi $hereguiremnds afthe criteria.
Bfcpnrroc (oat afs~qaeme) Will demonstrate this objective in conjunction with the wash d o m drill ai 6:OO PM on February B 7,2003 at the Key Largo Fire Dcparlment. Discussion will take place in the EOC regarding parapaaphs one and three. This activity can Be re-demonstrated iiushg the ma!mtion, y ~ r t dwhen necessary, in order to satisfy the requirements of the crigerfa
Criterion 3.d.2: Impediments to evacuation a r e identified and resolved.
NUR REG-0654, J. 1O.k)
Extent of Play OROs should demonstrate the capability, as required by the scenario, to identify and take appropriate actions concerning impediments to evacuation. Actual dispatch of resources to deal with impediments, such as wreckers, need not he demonstrated; however, all contacts, actual or simulated, should be logged.
AI1 activities must be based on the OROs plans and procedures and completed as they would he in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: (out of sequence) Miami-Dade Police \Kill demonstrate this through interviews at Tamiami Park on January 8,2003 at 9:OO AM. This activity can be re-demonstr&?d during the evaluation, if and when necessar).,in order lo satisfy the requirements of the criteria Monroe (Ocean Reef): Monroe County Sheriffs Office will demonstrate this by interview during the exercise.
- 4. FIELD MEASUREMENT AND ANALYSIS
$.a - Flume Phase Field Measurements and Analysis:
Criterion 4.a.l: The field teams are equipped to perform field measurements of direct radiation exposure (cloud and ground shine) and to sample airborne radioiodine and particulates. (NUREE0654, E l @1.7,8,9)
Extent of Plav Field teams should he equipped with all instrumentation and supplies necessary to accomplish their mission. This should include instruments capable of measuring gamma exposure rates and detecting the presence of beta radiation. These instruments should he capable of measuring a range of activity and exposure, including radiological protectiodexposure control of team members and detection of activity on the air sample collection media, consistent with the intended use of the instrument and the OROs plans and procedures. An appropriate radioactive check source should he used to veri@ proper operational response for each low range radiation measurement instrument (less than 1 Wu) and for high range instruments when available. If a source is not available for a high range instrument, a procedure should exist to operationally test the instrument 16
before entering an area where only a high range instrument can make useful readings.
All activities must be based on the QROs plans and procedures and completed as they would be in an actual emergency, unless noted above or othervise indicated in the cxtent-of-play agreement.
StatepOSEEQF):
DQSWEOF (HBORBWC): RRC will use instrumentation and measurement techniques as stated in SOPS. For trainingpurposes Criterion 4.a2: Field teams are managed to obtain sufficient information to help characterize the release and to control radiation exposasre (NUREG 0654,812; 1.8, 11; J.1O.a)
Extent of Play Responsible Offsite Response Organizations (QRQs) should demonstrate the capability to brief teams on predicted plume location and direction, travel speed, and exposure control procedures before deployment.
Field measurements are needed to help characterize the release and to supprt the adequacy ofimplemented protective actians or to be a factor in modifying prutective actions. Teams should be directed to take measurements in such locations, at such times to provide information suficient to characterize the plume and impacts.
If the responsibility to obtain peak measurements in the plume has been accepted by licensee field monitoring teams, with cuncurrence from OROs, there i s no requirement for these measurements do be repeated by State and focal monitoring teams. If the licensee teams do not obtain p a k measurements in the plume, it is the OROs decision as to whether peak messurements are necessary to sufficiently characterize the plume. The sharing and coordination of plume measurement information among all field teams (licensee, Federal, and ORO) is essential. coordination concerning transfer of samples, including a chain-of-custody fom, to a radiological laboratory should he demonstrated.
OROs should use Federal resuurces as identified in the Federal Radiological Emergency Response Plan (FEW), and other resources (for example, compacts, utility, etc.), if available. Evaluation ofthis criterion wil%take into consideration the level of Federal and other resources participating in the exercise, All activities must be based on the 0 s plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extcnt-of-play-ageement.
State (DOSEEOF):
~
DOSEEOF (DOH/BRC): RRC will use instrumentation and measurement techniques as stated in SOPs. For training purposes ordy Criterion 4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected.
Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has k e n collected on the sampling media. (NUREG-0654, I.
9)
Extent of Play Field teams should demonstrate the capability to report measurements and field data pertaining to the measurement of airborne radioiodine and particulates and ambient radiation to the field team coordinator, dose assessment, or other appropriate authority. If samples have radioactivity significant(y above background, the appropriate authority should consider the need for expedited laboratory analyses of these samples. OROs should share data in a timely manner with all appropriate OROs. All methodology, including contamination control, instrumentation, preparation of samples, and a chain-of-custody form for transfer to a laboratory, will be in accordance with the OROs plan and/or procedures.
OROs should use Federal resources as identified in the I W X P , and other resources (for example, compacts, utility, etc.), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.
All activities must be must be based on the ORBS plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
State (DOSEEOF):
- DOSEEOF (DQW BRC): BRC will use instrumentation and measurement techniques as stated in SOPs. For trainingpurposes only.
Sub-Element 4.c-La horatory Operations Criterion 4.c.l: The laboratory is capable of performing required radiological analyses to support protective action decisions. (NUREG-0654, C.3; J.11) 18
Extent of Play The laboratory staff should demonstrate the capability to follow appropriate procedures for receiving samples, including logging of infomation, preventing contamination ofthe laboratory, preventing buildup of background radiation due to stored samples, preventing cross contamination ofsarnplcs, preserving samples that may spoil ( for example, milk),
and keeping track of sample identity. In addition, the laboratory staff should demonstrate the capability to prepare samples fOr conducting measurements, Ihe laboratory should be appropriately equipped to provide analyses of media, as requested, on a timely basis, of sufflcirnt quality and sensitivity to support assessments and decisions as anticipated by the 8 8 0 s plans and procedures. The laboratory (laboratories) instrument calibrations should be traceable to standards provided by the National Institute of Standards and Technology. Labaratury methods used 60 analyze typical radionuclides released in a reactor incident should be as described in the plans and procedures. New or revised methods may be used to analyze atypical radionuclide releases (for example, transuranics or as a result of a terrorist event) or ifwarranted by circumstances ofthe event. Analysis may require resources beyond those ofthe ORO.
The laboratory staff should be qualified in radioanalytical techniques and contamination control procedures, OROs should use Federal resourcces as identified in the FRF,RP, and other resources (for example, compacts, utility, nuclear insurers, etc.), if available. Evaiuation ofthis criterion
\%illtake into consideration the level of Federal and other resources participating in the exercise.
All activities must be based on the OROs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play ageement.
State (DQSE/EQF):
~
DOSEIIEOF (DQWBRC): BRC will use instrumentation and measurement techniques as stated in SOPS. Far trainingpurposes on&
19
- 5. EMERGENCY NOTIFICATION AND PUBLIC INFORMATION 5.a -Activation of the Prompt Alert and Notification System:
Criterion 5.a.l: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance. (10 CFH Part So, Appendix E.IV.D and NUREG-0654, E.5,6,7)
Extent of Phv Responsible Offsite Response Organizations (OROs) should demonstrate the capability to sequentially provide an alert signal followed by an initial instructional message to populated areas (permanent resident and transient) throughout the 10-mile plume pathway EPZ. Following the decision to activate the alert and notification system, in accordance with the OROs plan and/or procedures, completion of system activation should be accomplished in a timely manner (will not be subject to specific time requirements) for primary alertinghotification. The initiaf message should include the elements required by current FEMA REP guidance.
Offsite Response Organizations (OR&) with route alerting as the primary method of alerting and notifying the public should demonstrate the capability to accomplish the primary route alerting, following the decision to activate the alert and notification system, in a timely manner (will not be subject to specific time requirements) in accordance with the OROs plan and/or procedures. At least one route needs to be demonstrated and evaluated. The selected route(s) should vary From exercise to exercise. However, the most difficult route should be demonstrated at least once every six years. AI1 alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extent-of-play. Actual testing ofthe mobile public address system \%ill be conducted at some agreed-upon location. The initial message should include the elements required by current FEMA REP guidance.
For exercise purposes, timely is defined as the responsible OR0 personnelirepresentatives demonstrate actions to disseminate the appropriate informatiordinstructions with a sense of urgency and without undue delay. If message dissemination is to be identified as not having been accomplished in a timety manner, the evaluator(s) will document a specific delay or cause as to why a message was not considered timely.
Procedures to broadcast the message should be fully demonstrated as they would in an 20
actual emergency up to the point of transmission. Broadcast of the message(s) or test messages is. no; required. The alert signal activation may be simulated. However, the procedures should be demonstrated up to the point of actual activation, The capability ofthe primary notification system to broadcast an instructional message on a 24-hour basis should be verified during an interview with appropriate personnel from the primary notification system.
All activities for this criterion must be based on the OROs plans and procedures and completed as they ~ u l be d in an actual emergency, except as noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: Once the final decision to implement Protective Actions is made, a silent test ofthe sirens will be demonstrated in conjunction with the simulated release of EAS messages.
Monroe: (our ~ J s e 9 u m s 4Notification to Ocean Reef Public safety to commence route alerting will be demonstrated in conjunction with the simulated release of EA§ messages. A silent route alerting simulation of one route wiil be demonstrated on February 19,2003. This mstivljr can be re-di?waons!rati?dduring the ev5iuatioi-t~grind when necessary, in order 10 satisJy !he requirements of the crik?r;lL Criterion 9.8.3: Activities associated with FEMA approved exception areas (where appiicabje) are completed within 45 mimtes folBowing the initial decision by alathorized offsite emergency olEciakisaleto notify the publie of an emergency situation. Sackssp alert and notification of the public is completed within 45 minutes following the detection by the OR0 of a M u r e of the primary alert and notifisation system. (NUREGQSM, E. 6, Appendix 3 . 3 2 . ~ )
~ x t e n of t
Offsite Response Organizations (ORUs) with FEMA-approved exception areas (identified in the approved Alert and Notification System Design Repoe) 5-10 miles from the nuclear power plant should demonstrate the capability to accomplish primary alerting and notification of the exception area(s) within 45 minutes following the initial decision by authorized offsite emergency officials ti, notify the public of an cmergency situation, The 45-minute clock will begin when the OROs make the decision to activate the alert and notification system for the first time for a specific. emergency situation, The initial message should, ab a minimum, include: a statement that an emergency exists at the plant and where to obtain additional information.
For exception area alerting, at least one S - O M needs
~~ to be demonstrated and evaluated.
21
The selected route(s>should vary from exercise to exercise. However, the most dificult route should be demonstrated at least once every six years. All alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extcnt-of-play. Actual testing of the mobile public address system will be conducted at some agreed-upon location.
Backup alert and notification of the public should be completed within 45 minutes following the detection by the OR0 of a failure of the pnmaq alert and notification system. Backup route alerting only needs to be demonshated and evaluated, in accordance with the OROs plan and/or procedures and the extent-of-play agreement, if the exercise scenario calls for failure of any portion of the primary systemjs), or if any portion of the primary system(s) actually fails to function. If demonstrated, only one route needs to be selected and demonstrated. All alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extent-of-play. Actual testing of the mobile public address system will be conducted at some agreed-upon location.
All activities for this criterion must be based on the QROs plans and procedures and completed as they would be in an actual emergency, except as noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: If there is a siren site down, after Miami-Dade County simulates siren sounding, this objective will be demonstrated (backup route alepting around that site) by discussion at the EOC.
Monroe (Ocean Reef): There are no sirens in Monroe County (see 5.a. 1 .)
5.b - Emergency Information and Instructions for the Public and the Media:
Criterion 5.b.l: QROs provide accurate emergency information and instructions to the public and the news media in a timely manner. (NUREG-0654, E. 5, 7; G . h , G.4.c)
Extent of Play Subsequent emergency information and instructions should be provided to the public and the media in a timely manner (will not be subject to specific time requirements). For exercise purposes, timely is defined as the responsible O R 0 ~rsonnelirepresentatives demonstrate actions to disseminate the appropriate information/instructions with a sense of urgency and without undue delay. if message dissemination is to he identified as not having been accomplished in a timely manner, the evaluator(s) will document a specific 22
delay or cause as to why a message was not considered timely.
The ORQ should emure that emergency information and instructions are consistent with protective acfion decisions made by appropriate officials, The emergency information should contain all necessary and applicable instructions ( for example, evacuation instructions, evacuation routes, reception center locations, what to take when evacuating, infomation concerning pets, shelter-in-place instructions, information concerning protective actions for schoois and special populations, public inquiry telephone number, etc.) to assist the public in carrying out protective action deckions provided t0 them. The QRO should also be prepared to disclose and explain the Emergency Classification Level (ECL) of the incident. At a minimum, this information must be included in media briefings a r d o r media releases. OROs should demonstrate the capability to use language that is clear and understandable to the public Within both the plume and ingestion pathway EPZs. This includes demonstration of the capability to use familiar landmarks and boundaries to describe protective action areas.
The emergency information shodd be all-inclusive by including previously identified protective action areas that are still valid, as well as new areas. The OKOs should demonstrate the capability to ensure that emergency infomation that is no longer valid is rescinded and not repeated by broadcast media. In addition, the OROs should demonstrate the capability to ensure that current einergency information is repeated at pre-established intervals in accordance with the plan andor procedures.
OR05 should demonstrate the capability to develop emergency information in s non-English languag when required by the plan andor procedures.
If ingestion pathway measures are exercised, OR05 should demonstrate that a system exists for rapid dissemination of ingestion pathway information to pre-determined individuals and businesses in accordance with the OROs plan ancllor procedures.
ORQs should demonstrate the capability to provide timely, accurate, concise, and coordinated information to the n e w media for subsequent dissemination to the public, This would include demonstration of the capability to conduct timely and pertinent media briefings and distribute media releases as the situation warrants. The ORQs should demonstrate the capability to respond appropriately to inquiries from the news media. All infomation presented in media briefings and media rcleases should be consistent with protective action decisions and other emergency infomation provided to the public.
Copies of pertinent emergency information (for example, Emergency Alert System
[EAS] messages and media releases) and media infmnation kits should be available for dissemination to the media.
OROs should demonstrate that an effective system is in place for dealing with calls to the public inquiry hotline, Hotline staff should demonstrate the capability to provide or obtain accurate information for callers or refer them to an appropriate infonnation source.
Information from the hotline staff, including information that corrects false or inaccurate information when trends are noted, should be included, as appropriate, in emergency 23
information provided to the public, media briefings, andor media releases.
All activities for this criterion must be based on the OROs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: EAS messages will be generated in English and Spanish to demonstrate this objective.
Monroe (Ocean Reef): The Monroe County Information Center will be activated and will demonstrate the ability to provide public information and squelch rumors by working with Public Information Officers and EOC staff. One ( 1 ) Answer Center operator will be used. Monroe County Public Information Officers will prepare press releases and participate in press conferences held at the ENC. PlOs in the EOC will coordinate the release of media releases with Rumor Control, the ENC, the EOF and the EOC as appropriate. EAS messages will be released from the ENC. Press releases may be released from either the EOC or the EOF with appropriate coordination. EAS messages wi11 be generated in English to demonstrate this objective.
State (FSERT, ENC): In Agrecment
- 6. SUPPORT OPERATION/FACILITIES 6.a -Monitoring and Decontamination of Evacuees and Emergency Workers and Registration of Evacuees:
Criterion &%l: The reception centedemergency worker facitity has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers. (NUKEG-0654, J.1O.h; J.12; K5.a)
Extent of Play Radiological monitoring, decontamination, and registration facilities for evacuees/emergency workers should be set up and demonstrated as they would be in an actual emergency or as indicated in the extent-of-play agreement. This would include adequate space for evacuees vehicles. Expected demonstration should include 1/3 of the monitoring teamdportal monitors required to monitor 20% of the population allocated to the facility Mithin 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Before using monitoring instrument(s), the monitor(s) should demonstrate the process of checking the instrument(s) for proper operation.
24
Staff responsible for the radiological monitoring of evacuees should demonstrate the capability to attain and sustain a monitoring productivity rate per hour needed to monitor the 20% emergency planning zone (EPZ) population planning base within about 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. This monitoring productiviq rate per hour is the number of evacuees that can be monitored per hour by the total compiement ofnionitors using an appropriate monitoring procedure. A minimum of six individuals per monitoring station should be monitored, using equipment and procedures specified in the plan andor procedures, to allow demonstration of monitoring, decontamination, and registration capabilities. The monitoring sequences for the first six simulated evacuees per monitoring team will be timed by the evaluators in order to determine whether the twelve-hour requirement can be met. Monitoring of emergency workers does not have to meet the twelve-hour requirement. However, appropriate monitoring procedures should be demonstrated for a minimum of two emergency workers.
Decontamination of evacueedemergency workers may be simulated and conducted by interview, The availability of provisions for separately showering should be demonstrated or explained. The staff should demonstrate provisions for limiting the spread of contamination. Provisions could include floor coverings, signs and appropriate means
( f ~ example, r pafltions, roped-off areas) to separate clean from potentially contaminated areas. Provisions should also exist to separate contaminated and uncontaminated individuals, provide changes of clothing for individuals whose clothing is contaminated, and store contaminated clothing and personal belongings to prevent further contamination of evacuees or facilities. In addition, for any individual found to be contaminated, procedures should be discussed concerning the handling of potential contamination of vehicles and personal belongings.
Monitoring personnel should explain the use of action levels for determining the need for decontamination. They should also explain the procedures for referring evacuees who cannot be adequately decontaminatcd for assessment and follow up in accordance with the OWOs plans and procedures. Contamination of the individual will be determined by controller inject and not simulated with any Iow-level radiation source.
The capability to register individuals u p n completion ofthe monitoring and decontamination activities should be demonstrated, The registration activities demomstrated should include the establishment of a registration record for each individual, consisting ofthe individuals name, address, results ofmonitoring, and time of decontamination, if any, or as otherwise desigmated in the plan. Audio recorders, caincordcrs, or written records are all acceptable means for registration.
All activities associated with this criterion must be based on the OROs plans and procedures and cornplctcd as they would be in an actual emergency, unless otherwise indicated in the extent-of-play agreement.
Miami-Diade: (out ofsequence) This objective will be demonstrated on January 8, 2003 at Tsmiami Park (anticipated arrival = 77,000), 4 portail monitoring stations will be demonstrated. A miniinlam of two emergency workers will be 25
decontaminated. This activiry can be re-detnonslrated daring the evaluation.
and when necessary, in order to satisjir the requirements oftlie criteria.
Monroe: (out of sequence) Monroe County will demonstrate EW and evacuee monitoring and decontamination on February 17,2003 at 6:OO PM at the Key Largo Fire Station. Two workers niII also be monitored. One of these workers will be found to be contaminated and will be decontaminated. Reception Center, registration, and decontamination of evacuees will be demonstrated at the same time. This acfivitycan be re-demonstrated during the evaluation, ifand when necessary, in order to satisfy the requirements of the criteria.
6.b - Monitoring and Decontamination of Emergency Worker Equipment:
Criterion 6.b.l: The facility/ORO has adequate procedures and resourses for the accomplishment o f monitoring and decontamination of emergency worker equipment, including vehicles. (NUREG-0654,K5.b)
Extent of Play The monitoring staff should demonstrate the capability to monitor equipment, including vehicles, for contamination in accordance with the Offsite Response Organizations (OROs) plans and procedures. Specific attention should be given to equipment, including vehicles, that was in contact with individuals found to be contaminated. The monitoring staff should demonstrate the capability to makc decisions on the need for decontamination of equipment, including vehicles, based on guidance levels and procedures stated in the plan andor procedures.
The area to be used fer monitoring and decontamination should be set up as it would be in an actual emergency, with all route markings, instrumentation, record keeping and contamination control measures in place. Monitoring procedures should be demonstrated for a minimum ofone vehick. It is generally not necessary to monitor the entire surface of vehicles. However, the capability to monitor areas such as radiator gills, bumpers, wheel wells, tircs, and door handles should be demonstrated. Interior surfaces of vehicles that were in contact with individuals found to be contaminated should also be checked.
Decontamination capabilities, and provisions for whicles and equipment that cannot be decontaminated, may be simulated and conducted by interview.
26
All activities associated with this criterion nimt be based on the OROs plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: (out ofsequence) This will be demonstrated during the emergency wash down drill on January 8,2003 at Tamiami Park. One vehicle w i l l bc monitored and decontaminated. This activity can be n?-demomlrated during the
~ W Z ! U Q ~ ~iOf ~
~n, k when b necessary, in order to satisfy the requf7ema8soJthe criteria 6.6: - Temporary Care of Evacuees:
Criterion 4.c.l: Managers of congregate care facilities demonstrate that the centers have resources to provide services and a c ~ o ~ ~ ~ ~ ~ dconsistent atiopl~
with American Red Cross planning guidelines. (Found in MASS CARE-Preparedness Qperations, ARC 3Q31). ,Managers demonstrate the procedures to assure Itbat evacuees have been monitored for contamination and hare been decontaminated as appropriate prior to entering congregate care facilities. (NUREG-0654,J.dO.h, J.12)
Extent of Play Under this criterion, demonstration of congregate care centers may be conducted out of sequence with the exercise scenario. The evaluator should conduct a walk-through ofthe center to determine, through observation and inquiries, that the services and acconamodations are consistent with ARC 303 1. In this simulation, it is not necessary to set up operations as they would be in an actual emergency, Alternatively, capabilities may be demonstrated by setting up stations for various services and providing those sewices to simulated evacuees. Given the substantial ditkrences between demonstration and simulation of this objective, exercise demonstration expectations should be clearly specified in extent-of-play agreements, Congregate care staff should also demonstrate the capability to ensure that evacuees have been monitored for contamination, have been decontaminated as appropriate, and have been registered beforc entering the facility. This capability may be determined through an interview process.
If operations at the center are demonstrated, material that would be difficult or expensive to transport (e.g., cots, blankets, sundries, and large-scale food supplies) need not be physically available at the facility (facilities). However, availability of such items should be verified by providing the evaluator a list of sources with locations and estimates of quantities.
27
AI1 activities associated with this c.riterion must be based on the OKO's plans and procedures and completed as they would be in an ac.tual emergency, unless noted above or otherwise indicated in the extent-of-play agreement.
Miami-Dade: (out of sequence) This wdl be demonstrated on January 8,2003 at the 'Tamiami Park Youth Fair Grounds. Will be accomplished by a walk through.
One third of the primary shelters ( 5 ) will be visited the day of the practice exercise on January 16, 2003. This activiry can be re-demonstrated during the evaluation, ifand when necessary, in order to satkfy the requirements of the criteria.
Monroe: (outfor sequence) This wiil be demonstrated by interview during the exercise on February 19,2003 at the Key Largo Fire Station: depending on the personnel (school, ARC, etc.) needed for interview by the evaluators. This activity can be re-demonstrated during the evaluation, if and when necessary, in order to satisfy the requirements of the criteria 6.d -Transportation and Treatment of Contaminated Injured Individuals:
Criterion 6.d.l: The facility/OHO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical senriees to contaminated injured individuals.
(NUREG-0654,F.2; H.lO; IC5.a, h; L.l, 4)
Extent of Play hbnitoring, decontamination, and contamination control efforts will not delay urgent medical care for the victim.
Offsite Response Organizations (OKOs) should demonstrate the capability to transport contaminated injured individuals to medical facilities. An ambulance should be used for the response to the victim. However, to avoid taking an ambulance out of service for an extended time, any vehic.le (e.g., car, truck, or van) may be utilized to transport the victim to the medical facility. Normal communications between the ambulance/dispatcher and the receiving medical facility should be demonstrated. If a substitute vehicle is used for transport to the medical facility, this communication must occur before releasing the arnbu1anc.efrom the dnl!. This communication would include reporting radiation monitoring results, if available. Additionaily, the anibulance crew should demonstrate, by interview, knowledge of where the ambulance and crew would be monitored and decontaminated, if required, or whom to contact for such information.
Monitoring ofthe victim may be performed before transport, done enroute, or deferred to the medical fadity. Before using a monitoring instrurnent(s), the monitor(s) should demonstrate the process of checking the instrument(s) for proper operation. All 28
monitoring activities should be completed as they would be in an actual emergency.
Appropriate contamination control measures shouYd be demonstrated before and during transport and at the receiving medical facility.
'The medical facility should demonstrate the capability to activate and set up a radiological emergency area for treatment. Equipment and supplies should be available for the treatment of contaminated injured individuals.
The medical facility should demonstrate the capability to make decisions on the need for decontamination of the individual, to follow appropriate demontamination procedures, and to maintain records of all survey measurements and samples taken. All prosedures for the collection and analysis of samples and the decontamination of the individual should be demonstrated or described to the evaluator.
All activities associated with this criterion US? he based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or obhenvise indicated in the extent-of-play agreement.
Miami-Dade: Accomplished at Mercy Hospital during the MS-I Drill on November 6,2002.
APPENDIX 4 EXERCISE SCENARIO Attachcd is the summary ofthe simulated sequence of events, which was used as the basis for invokmg emergency response actions by OROs in the Turkey Point Nuclear Power Plant exercise on February 19,2003.
(Final Report Only) 32
3.2 SCENARIO TIMELINE 1300 13 Emergency Containment Filters, Emergency Containment Coolers, and Containment Spray (if required)("B" CSP fuses are replaced and pump is back in service) have scrubbed and cooled the containment and the reduction in containment pressure is eliminating the release through the containment isolation purge exhaust valves POV-2602 and PBV-2603. Plant Vent radiation readings begin to decline. Field monitoring activities continue. The emergency response teams continue to stabilize the reactor, verify safe shutdown and evaluate containment integrity. Discussions of reco\'ery and reentry should begin as the release rate continues to decline.
1415 Recovery actions should be considered at this time with the identification of personnel for back shifts, possible de-escalation of the General Emergency, and logistical needs for continued operation of the facility.
1515 14 With the completion of ai! Mate, local and utility objectives, terminate Exercise Play.
EVENT# EVENT The EOF should have been declared operational.
I110 9 Conditions are in place for declaration of a §ITE AREA EMERGENCY, based on RCS leakage greater the SO gpm and greater than charging pump capacity.
When the operators respond to the ATWS and !he reactor is ?ripped. three RCCAs stick out.
(SIMULATQR NOTE - .05jurl dunzuge romped in over 5 - IO minutes)
Both buses transrer to the Unit 3 Startup Transformer and stari all required ECCS Equipment.
I125 The Post Accident Hydrogen Monitor is placed into service (needs lo he - 30 tninuks after SI).
1330 The damaged fuel region ofthe core is releasing gas gap activity. Containment High Range radiation Monitors (CHRRMs) will begin lo increase.
121s IO Containment ternpesa?ure and pressure increase (less than 20 psig). Containment hydrogen concentration continues to increase. CHWRMs indications are rising. The containment isolation purge exhaust valves POV-3-2602 (outside containmenl) and POV 3-2603 (inside containment) Stat? t o leak (kak through due to containment pressure). Effom begin to confirm containment status with the onset oftlie leakage, IS Conditions are in place for the declaration of a GENERWL EMERGENCY. based on the following conditions: RCS leakage greater than 58 gpm ANB)RCS leakage greater ahan available charging pump capacity AND Loss of containment integrity which provides a flowpath $0the environment.
Protective Action Recommendations {PARS) should be generated on plant conditions.
I220 17 Readings on 8-14 and the plant vent SPBNG increase as the release initiates.
Field teams should be dispatched to find the plume arid PARS should be upgraded based (if not already) on significant core damage and the loss of containment integrity.
II.IIPTN
3.2 SCENARIO TlMELlNE TlME EVENT# EVENT 0930 The fire team has arrived on the scene at the Unit 3 CCW Pump Area 2nd finds a fire underway. The fire learn leader advises the Control Room that offsisile fire suppod should be requested (simulated).
4 Conditions are in place for the declaration of an ALERT EMERGENCY based on an uncontrolled fire potentially affecting safety systems and offsite fire suppod is necessary.
Acrivalion of the Emergency Response Facilities has been initiated.
I000 5 A flange leak develops on the CCW line to the Containment Spray Pump (CSP) Seal Water Heat Exchangers. The water is spraying on the control switches for both CSPs. An operator will be dispatched in response to a Control Room annunciator for low CCW flow to the CSP cooler.
I005 6 A previously unidentified crack in a pipe-to-elbow weld on the 3A Cold Leg begins 10leak reactor coolant to the containment at approximately 3 gpm. Within minutes, containment sump level increases.
The onsite emergency response facilities (TSC 2nd OSC) should ha\*ebeen declared operational.
1015 The technician perfoming the LLRT on POV-3-2602 and POV-3-2603 calls and reports that during the test the pressure regulator failed and overpressurized the annulus. A loud pop was heard and the annulus depressurized. PQV-3-2602 appears to be off its closed seat.
IO75 Operators and the STA have conducted RCS leak rate calculations using chargindietdown mismatch and containment sump levels increax. RCS leakage is determined to be greater than the Technical Specification limit of 11 gprn unidentified leakage.
I030 A controlled reactor shutdown will be initialed within the hour. per Tech Specs.
IO40 The fire is out, but still smoldering.
1055 7 The cold leg RCS leakage increases to approximately IO0 GPM (leak ramps up over
- 5 minutes). Additional charging pumps are maintaining Pressurizer (PRZ) level.
Efforts to quantify the increase are initiated. Containment coolers are limiting the increase in containment temperature and pressure. Controlled shutdown continues (if already started) but is increased to 5% per minute.
110s 8 Increasing leakage from the failed weld. to approximately 1600 GPM. exceeds charging pump capacity. Operators will anempt to trip the reactor but it fails to trip (Anticipated Transient Without Scram - ATWAS).
In ,,N
FLORIDA POWER AND LIGHT COMPANY TURKEY PB%NTNUCLEAR PLANT 2003 EMERGENCY PREPAREDNESS NRC EVALUATED EXERCISE FEBRUARY 19,2003 3.2 SCENARiO TlMEklNE 0730 Initial conditionsesiablish Unit 4 operating at 100% power, in the middle ofcore life.
Unit 3 power histmy has been full power operation for the last 180 days. Unit 4 is in Mode 5, Cold Shutdown.
Six-month Sun-eillanse Testing is scheduled to be conducted on the containment isolation purge exhaust valves POV-3-2602 and POV-3-9603 and all administrative requirements are in place.
4 3 Hi Head Safety Injestion ("SI) Pump is out ofservice for maintenance.
U3 CCW Deluge System is QBS for clapper valve replacement.
MOV-536 (PQRY Block Valve) has been closed due to PORY-455C leaking PRMS Channel R-15 is out o f service. for planned maintenance due to detector failure.
Dcmand on the system is high, with an anticipated peak of 17,500 Mwc. Service area conditions are normal. Weather has been sunny and hot. Forecast is for pertly cloudy skies, temperattIreS in the upper 90's and Occasional showers for the next four days. Current temperature is 9 2 O , with winds from the east at 5 - IO miles per hour.
0800 I A Chemisnry Technician pulling a SFP sample from SFP f i x Room, trips and fractures his arm. spilling the sample over him.
0810 RCS flow transminer FT-3-414 faits low. l&C will troubleslwot the failure and determine that the problem is inside containment. (No! recovered during the drill).
0845 2 A TQRNABO has been reported within the Owner Controlled Area (located near the Hazardous Material Storage Building, no equipment or slructure damage) Conditions are in place for the Decsaration of a Notification o f Unusual Event.
0915 a A fire alarm in the Unit 3 CCW Pump area, Alarm Point 28, comes into the Control Room. The Unit 3 Control Room activates the fire team to combat the fire. l h e fire impacts !he 3 8 CCW Pump motor wiring conduit and motor filters, and takes out the 38 CCW Pump (minor damage to the wiring which can be repaired).
.