Licensee Report of Defective Refurbished ValvesML031150155 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Issue date: |
08/24/1988 |
---|
From: |
Rossi C Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
References |
---|
IN-88-048, Suppl 1, NUDOCS 8808180368 |
Download: ML031150155 (7) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION:
WASHINGTON, D.C. 2055E
August 24, 1988 NRC INFORMATION NOTICE NO. 88-48, SUPPLEMENT .: LICENSEE REPORT OF DEFECTIVE
PFFURBISHED VALVES
Addressees
All holders of operating licenses or construction permits for nuclear power
reactors.
Purpose
This information notice supplement is being provided to present additional
information regarding the valves discussed in Information Notice 88-48. It
is expected that recipients will review this information for applicability
to their facilities and consider actions, as appropriate, to avoid similar
problems. However, suggestions contained in this information notice do not
constitute NRC requirements; therefore, no specific action or written response
is required.
Descriptior of Circumstances:
Information Notice 88-48 discussed information from Pacific Gas and Electric
(PG&E) about a potential problem with 2-inch valves that were leaking steam
at the bonnet and packing.
The NRC received a letter from the Henry Vogt Machine Company (Vogt Company),
dated August 1, 1988, stating its position on the Diablo Canyon valve matter
and providing additional information on the distinguishing features of its
valves. The letter received from the VoQt Company is attached. The letter
also indicates the Vogt Company belief that the Diablo Canyon valves were
counterfeit and not refurbished Vogt valves and corrects a reference to the
Vogt figure number in the original information notice.
8 18036 K' /. - ;-v
IN 88-48, Supplement 1 August 24, 1988 No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the technical
contact listed below or the Regional Administrator of the appropriate regional
office.
aRoE ossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact:
Edward T. Baker, NRR
(301) 492-3221 Attachments:
1. Henry Vogt Machine Co. letter dated 8/1/88
2. List of Recently Issued NRC Information Notices
~. -. Attachment 1 IN 88-48, SupDle-ment 1 HE NRYS MACHINE CO.
INiCOMORAYTD P. 0. Box 1918 - LOUISVILLE, KY. 40201-1918 - U.S.A.
August 1, 1988 United States Nuclear Regulatory Commission
Office of Nuclear Reactor Regulation
Washington. D.C. 20555 Attention: Mr. Charles E. Rossi, Director
Division of Operational Events Assessment
Dear Sir:
We are in receipt of NRC Information Notice No. 88-48.
After careful review of the notice, we wish to bring the
following points to your attention:
1. We believe the title "Licensee Report of Defective
Refurbished Valves" is misleading. The valves are
counterfeit; we do not believe them to be refurbished.
2.. In the third paragraph, you refer to "Vogt Figure No.
SW 12111". The valves at Diablo Canyon were actually
stamped "SW-13111". Vogt series SW-13111 is a full port
design as indicated in your "Discussion".
These valves, including forgings and parts of construction, were
not manufactured by Henry Vogt Machine Co. The outward
appearance of the counterfeit valves is so drastically different
from the Vogt series SW-13111 that any person knowledgeable of
our product or examining the product to the Vogt drawing would
have spotted the difference immediately. For example:
0 0 1. Vogt valves have round bonnet flanges; the counterfeit
OD valves have square bonnet flanges.
0
0,
to join
2. Vogt series SW-13111 uses a hex head cap screw
the body and bonnet; the counterfeit valves use a
stud/nut combination.
3. A number of the counterfeit valves have "swing gland
bolting", a design never used on Vogt SW-13111 valves.
Since 1880. Manufacturers of Ouality
MACHINES
FORGED STEEL VALVES. FITTINGS. STEAM GENERATORS. HEAT EXCHANGERS. TUBE-ICE
PHONE 502-634-1511
- FAX: 502-637-7344 Main Office and Plant - 1000 W. Ormsby Ave. - Louisville. Kentucky 40210-1810
- HENRi'O24. ¶ MIACHI.NE CO.
Attachment
1 United States Nuclear Regulatory Commission
August 1. 1988 I8-48, Supplement 1 Page 2
4. Vogt valves have the name "Vogt" forged
onto the side of
the body; the counterfeit valves have "Vogt"
stamped on
the side after an obvious grinding removed
the true
identity of the material (forging or casting)
manufacturer.
5. The end-to-end dimension of the counterfeit
valve is
shorter than Vogt series SW-13111.
Vogt has manufactured many valves for use in
both safety related
and non-safety related applications in nuclear
power plants.
Valves meeting ASME Section III or 1OCFR5O are
not stamped with a
series number such as SW-13111. The valves are
identified by the
drawing to which the valves were built.
We are concerned that there be no confusion
within the industry
between valves furnished by Vogt and the counterfeit
purchased by Pacific Gas & Electric for use valves
at Diablo Canyon.
Your cooperation in amending Notice No. 88-48 would be most
appreciated.
Yours very truly, Barbara Bronger, Manager
Nuclear Products Group
bb
cc: Mr. Harold Morgeson
Mr. Guy Jolly
IS -
Attachment 2 IN 88-48, Supplement 1 August 24, 1988 LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
In-formation Date of
Notice No. Subject Issuance Issued to
88-68 Setpoint Testing of Pres- 8/22/88 All holders of OLs
surizer Safety Valves with or CPs for nuclear
Filled Loop Seals Using power reactors.
Hydraulic Assist Devices
88-67 PWR Auxiliary Feedwater Pump 8/22/88 All holders of OLs
Turbine Overspeed Trip or CPs for nuclear
Failure power reactors.
88-66 Industrial Radiography 8/22/88 All NRC industrial
Inspection and Enforcement radiography licensees.
88-65 Inadvertent Drainages of 8/18/88 All holders of OLs
Spent Fuel Pools or CPs for nuclear
power reactors and
fuel storage facilities.
88-64 Reporting Fires in Nuclear 8/18/88 All holders of OLs
Process Systems at Nuclear or CPs for nuclear
Power Plants power reactors.
88-63 High Radiation Hazards 8/15/88 All holders of OLs
from Irradiated Incore or CPs for nuclear
Detectors and Cables power reactors, research reactors
and test reactors.
88-62 Recent Findings Concerning 8/12/88 All holders of NRC
Implementation of Quality quality assurance
Assurance Programs by program approval
Suppliers of Transport for radioactive
Packages material packages.
88-61 Control Room Habitability - 8/11/88 All holders of OLs
Recent Reviews of Operating or CPs for nuclear
Experience power reactors.
88-60 Inadequate Design and 8/11/88 All holders of OLs
Installation of Watertight or CPs for nuclear
Penetration Seals power reactors.
OL Operating License
CP - Construction Permit
IN 88-48, Supplement 1 August 24, 1988 No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the technical
contact listed below or the Regional Administrator of the appropriate regional
office.
Charles E. Rossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact:
Edward T. Baker, NRR
(301) 492-3221 Attachments:
1. Henry Vogt Machine Co. letter dated 8/1/88
2. List of Recently Issued NRC Information Notices
- SEE PREVIOUS PAGE FOR CONCURRENCE
- DOEA *SC:VIS:DRIS *C:VIB:DRIS *AD:DRIS *OI
JShapaker EBaker EWBrach BKGrimes WHutchison
8/15/88 8/15/88 8/15/88 8/15/88 8/18/88
CHBerlinger
8/18/88 8/l y/88
IN 88-48, Supplement 1 August xx, 1988 No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the technical
contact listed below or the Regional Administrator of the appropriate regional
office.
Charles E. Rossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact:
Edward T. Baker, NRR
(301) 492-3221 Attachments:
1. Henry Vogt Machine Co. letter dated 8/1/88
2. List of Recently Issued NRC Information Notices
4C:V:DRIS
EBaker EWBrash r
8/2*-/88 8/)9/88 8// i88 D:DOEA
CHBerlinger CERossi
8//0 /88 8/ /88
|
---|
|
list | - Information Notice 1988-01, Safety Injection Pipe Failure (27 January 1988)
- Information Notice 1988-03, Cracks in Shroud Support Access Hole Cover Welds (2 February 1988, Topic: Stolen)
- Information Notice 1988-04, Inadequate Qualification and Documentation of Fire Barrier Penetration Seals (5 February 1988, Topic: Fire Barrier, Fire Watch, Stolen)
- Information Notice 1988-05, Fire in Annunciator Control Cabinets (12 February 1988, Topic: Stolen)
- Information Notice 1988-06, Foreign Objects in Steam Generators (29 February 1988, Topic: Stolen)
- Information Notice 1988-07, Inadvertent Transfer of Licensed Material to Uncontrolled Locations (7 March 1988, Topic: Stolen)
- Information Notice 1988-08, Chemical Reactions with Radioactive Waste Solification Agents (14 March 1988, Topic: Process Control Program, Stolen)
- Information Notice 1988-09, Reduced Reliability of Steam-Driven Auxiliary Feedwater Pumps Caused by Instability of Woodward PG-PL Type Governors (18 March 1988)
- Information Notice 1988-10, Memo of Understanding Between NRC and OSHA Relating to NRC-Licensed Facilities (53 FR 43950, October 31, 1988) (23 December 1988)
- Information Notice 1988-10, Memo of Understanding Between NRC and OSHA Relating to NRC-Licensed Facilities (53 Fr 43950, October 31, 1988) (23 December 1988)
- Information Notice 1988-10, Memorandum of Understanding Between NRC and Osha Relating to NRC-Licensed Facilities (53 Fr 43950, October 31, 1988. (23 December 1988)
- Information Notice 1988-11, Potential Loss of Motor Control Center And/Or Switchboard Function Due to Faulty Tie Bolts (7 April 1988)
- Information Notice 1988-12, Overgreasing of Electric Motor Bearings (12 April 1988)
- Information Notice 1988-13, Water Hammer & Possible Piping Damage Caused by Misapplication of Kerotest Packless Metal Diaphragm Globe Valves (18 April 1988)
- Information Notice 1988-14, Potential Problems with Electrical Relays (18 April 1988)
- Information Notice 1988-15, Availability of Us Food & Drug Administration (FDA) Approved Potassium Iodide for Use in Emergencies Involving Radioactive Iodine (18 April 1988)
- Information Notice 1988-15, Availability of Us Food & Drug Administration (Fda) Approved Potassium Iodide for Use in Emergencies Involving Radioactive Iodine (18 April 1988)
- Information Notice 1988-16, Identify Waste Generators in Shipments of Low-Level Waste to Land Disposal Facilities (22 April 1988)
- Information Notice 1988-17, Summary of Responses to NRC Bulletin 87-01, Thinning of Pipe Walls in Nuclear Power Plants. (22 April 1988, Topic: Safe Shutdown, Weld Overlay, Through-Wall Leak)
- Information Notice 1988-18, Malfunction of Lockbox on Radiography Device (25 April 1988)
- Information Notice 1988-19, Questionable Certification of Class Ie Components (26 April 1988)
- Information Notice 1988-19, Questionable Certification of Class IE Components (26 April 1988)
- Information Notice 1988-20, Unauthorized Individuals Manipulating Controls and Performing Control Room Activities (5 May 1988)
- Information Notice 1988-21, Inadvertent Criticality Events at Oskarshamn and at U.S. Nuclear Power Plants (9 May 1988, Topic: Shutdown Margin)
- Information Notice 1988-22, Disposal of Sludge from Onsite Sewage Treatment Facilities at Nuclear Power Stations (12 May 1988)
- Information Notice 1988-23, Potential for Gas Binding of High-Pressure Safety Injection Pumps During a Loss-Of-Coolant Accident (12 May 1988)
- Information Notice 1988-24, Failures of Air-Operated Valves Affecting Safety-Related Systems (13 May 1988)
- Information Notice 1988-25, Minimum Edge Distance for Expansion Anchor Bolts (16 May 1988, Topic: Earthquake)
- Information Notice 1988-26, Falsified Pre-Employment Screening Records (16 May 1988)
- Information Notice 1988-27, Deficient Electrical Terminations Identified in Safety-Related Components (18 May 1988)
- Information Notice 1988-28, Potential for Loss of Post-Loca Recirculation Capability Due to Insulation Debris Blockage (19 May 1988, Topic: Coatings)
- Information Notice 1988-29, Deficiencies in Primary Containment Low-Voltage Electrical Penetration Assemblies (24 May 1988)
- Information Notice 1988-30, Target Rock Two-State SRV Setpoint Drift Update (25 May 1988)
- Information Notice 1988-31, Steam Generator Tube Rupture Analysis Deficiency (25 May 1988)
- Information Notice 1988-32, Prompt Reporting to NRC of Significant Incidents Involving Radioactive Material (25 May 1988)
- Information Notice 1988-33, Recent Problems Involving the Model Spec 2-T Radiographic Exposure Device (27 May 1988)
- Information Notice 1988-34, Nuclear Material Control & Accountability of Non-Fuel Special Nuclear Material at Power Reactors (31 May 1988)
- Information Notice 1988-36, Possible Sudden Loss of RCS Inventory During Low Coolant Level Operation (8 June 1988)
- Information Notice 1988-37, Flow Blockage of Cooling Water to Safety System Components (14 June 1988, Topic: Ultimate heat sink)
- Information Notice 1988-38, Failure of Undervoltage Trip Attachment of General Electric Circuit Breakers (15 June 1988)
- Information Notice 1988-39, Loss of Recirculation Pumps with Power Oscillation Event (15 June 1988)
- Information Notice 1988-40, Examiners' Handbook for Developing Operator Licensing Examinations (22 June 1988)
- Information Notice 1988-41, Physical Protection Weaknesses Identified Through Regulatory Effectiveness Reviews (RERs) (22 June 1988)
- Information Notice 1988-41, Physical Protection Weaknesses Identified Through Regulatory Effectiveness Reviews (Rers) (22 June 1988)
- Information Notice 1988-42, Circuit Breaker Failures Due to Loose Charging Spring Motor Mounting Bolts (23 June 1988, Topic: Loctite)
- Information Notice 1988-43, Solenoid Valve Problems (23 June 1988, Topic: Stroke time)
- Information Notice 1988-44, Mechanical Binding of Spring Release Device in Westinghouse Type DS-416 Circuit Breakers (24 June 1988)
- Information Notice 1988-45, Problems in Protective Relay & Circuit Breaker Coordination (7 July 1988, Topic: Safe Shutdown)
- Information Notice 1988-46, Licensee Report of Defective Refurbished Circuit Breakers (8 July 1988)
- Information Notice 1988-47, Slower-than-Expected Rod-drop Times (14 July 1988)
... further results |
---|