IR 05000413/1980027

From kanterella
Jump to navigation Jump to search
IE Insp Repts 50-413/80-27 & 50-414/80-27,on 800929-1003.No Noncompliance Noted.Major Areas Inspected:Structural Concrete,Standby Nuclear Svc Water Pond Dam,Foundations & Site Preparation
ML20002B463
Person / Time
Site: Catawba  
Issue date: 10/23/1980
From: Conlon T, Harris J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20002B455 List:
References
50-413-80-27, 50-414-80-27, NUDOCS 8012110623
Download: ML20002B463 (4)


Text

-Q

'%)

p eso d'

'o UNITED STATES

~,

g NUCLEAR REGULATORY COMMISSION j,,

-

REGION 11

c

101 MARIETTA sT., N.W., SUITE 3100

g

,o ATLANTA, GEORGIA 30303

Report Nos. 50-413/80-27 and 50-414/80-27 Licensee: Duke Power Company 422 South Church Stre-Charlotte, NC 28242 Facility Name:

Catawba Nuclear Station Docket Nos. 50-413 and 50-414 License Nos. CPPR-116 and CPPR-117 Inspectien at Catawba site near Lake Wylie, South Carolina Inspector:

[)'S lb,

/C,/J 3 '7 L

/

g--

<

J. R. Harris Date Signed Accompanying Personnel:

J. Reyes, Philippine, A. E. C.

Approved W gr!M

/d -f.f - [o T. E. Conlon, Section Chief, RCES Branch Date Signed SUMMARY Inspection on September 29, to October 3, 1980 Areas Inspected This routine, unannounced inspection involved 32 inspector-hours on site in the areas of structural concrete, standby nuclear service water pond dam, foundations, site preparation and previously identified items.

Results Of the five areas inspected, no items of noncompliance or deviations were identified.

80123 3 g (pg5

.

.

DETAILS 1.

Persons Contacted Licensee Employees

  • D. G. Beam, Project Manager
  • D. L. Freeze, Construction Engineer
  • S. W. Dressler, Senior Construction Engineer
  • R. A. Morgan, Senior QA Engineer
  • H. D. Mason, Civil QA Engineer R. B. McCrary, Civil Construction Engineer
  • L R. Davison, Senior QC Engineer Other licensee employees cor sacted included five construction craf tsmen, and six technicians.
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on October 3, 1980 with those persons indicated in Paragraph I above.

3.

Licensee Action on Previous Inspection Findings (0 pen) Unresolved Item 50-413/80-24-02 and 50-514/80-20-02):

" Curing Compounds on Construction Joints".

Curing compounds were used on construction joints in apparent conflict with referenced paragraph 12 of ACI 301-72. Responsible design engineers claim that their design methods do not take credit for bond.

Construction joints are now being water cured. Specification CNS-1109.01 is being revised to clarify curing requirements and design calculations for safety related

!

structures are being reviewed. This item remains open pending examination

!

by RII:IE of the design calculations review.

(0 pen) Inspector Followup Item 50-413/80-20-01 and 50-414/80-20-01):

" Internal Pressure on Electrical Penetrations".

The licensee is having difficulty meeting the specified gas pressure requirements of 15 Psi at 72 degrees fahren! Lit.

Discussions with respon-l sible engineers and examination of site memo number ii-1361.00 disclosed that revised gas pressure requirements will be issued oy October 3, 1980.

This item remains open pending examination by NRC RII:IE of the revised l

storage controls.

l

!

4.

Unresolved Items

,

l

!

I l

l l

-

_

... _

_

..

.

.

-2-

,

Unresolved items were not identified during this inspection.

5.

Independent Inspection The inspector examined ongoing work activities in Units 1 and 2, the soils and concrete testing laboratory, the concrete batch plant and results of work on the standby nuclear service water dam.

No deviations or items of noncompliance were identified.

6.

Lakes, Dams and Canals - Review of Quality Assurance Implementing Pro-cedures - Units 1 and 2 The inspector performed a followup examination of procedures sad specif-ications concerning control of the standby nuclear service *iater pond dam.

Acceptance criteria examined by the inspector appear in section 2.0 and appendix 2g of the PSAR.

Controlling specifications, drawings and procedures examined by the inspector are:

a.

M-1, Inspection of Compacted Earthfills.

b.

M-26, Laboratory Soil Testing.

c.

CNS-1114.00-01, Specification on General Grading and Work for Con-struction of Earth, Dams and Fills.

d.

Drawing number CN1028-1, Dam Instrumentation.

Drawing number CN1027-1, Nuclear Service Water Pump Structure and e.

Intake.

f.

CP-302, Grouting Procedure for Standby Nuclear Service Water Dam Foundation Drains.

No deviations or items of noncompliance were identified.

7.

Containment (Structural Concrete) Review of Quality Assurance Implementing Procedures - Units 1 and 2 The inspector performed a followup examination of specifications and procedures concerning control of structural concrete. Acceptance criteria examined by the inspector appear in section 3.8 of the PSAR. Controlling procedures and specifications examined by the inspector are:

a.

Procedure M-2, Inspection of Design Concrete b.

CNS-1109.00-1, Specification for Concrete for Category I Structures

.

.

,. -

-

-

. -

-

.

.

. _.

_

._. - _ _. - _ _

_.

__

...

_.

.. _ _ _

.

.

_..

'

-

.

.

I-3-

,

c.

M-14, Cadweld Splice Inspection and Testing i

d.

I-2, Qualification of Cadweld Inspectors i

J-1, Certification of Cadweld Inspecters e.

f.

CP-68, Honeycomb Repair g.

CP-63 Curing of Design Concrete b.

P-1, Receiving Inspection i.

P-3, Storage Inspection j.

Control of Nonconforming Items i

No deviations or items of noncompliance were identified.

I

l 8.

Foundations, Review of Quality Assurance Implementing Procedures - Units 1 and 2 The inspector performed a followup examination of quality assurance con-l trols for category I foundations. Acceptance criteria appear in sections 2 and 3 of the PSAR.

Controlling documents examined in addition to those

'

listed in paragraphs 6 and 7 are:

'

M-6, Inspection of Foundation Grouting.

a.

b.

M-27, Soil Sampling, Core Drilling and Testing in the Field.

i c.

CP-63, Grouting the Foundation for the Reactor Building and Auxiliary Building.

No deviations or items of noncompliance were identified.

9.

Site Preparation - Review of Quality Assurance Implementing Procedures -

Units 1 & 2 The inspector performed a followup examination of quality assurance con-trols for site preparation. Acceptance criteria examined by the inspector appear in sections 2, 3 and 5 of the PSAR. Controlling documents examined by the inspector are the same as those listed in paragraphs 6, 7 and 8.

!

No deviations or items of noncompliance were identified.

l

!

!

i d

m

..

-.