Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
IR 05000413/1999302 | 12 October 1999 | NRC Operator Licensing Retake Exam Repts 50-413/99-302 & 50-414/99-302 (Including Completed & Graded Tests) for Tests Administered on 990921-23.Two Out of Three RO Candidates & One SRO Passed Retake Exam | Job Performance Measure |
IR 05000413/1999301 | 30 September 1999 | NRC Operator Licensing Exam Repts 50-413/99-301 & 50-414/99-301 (Including Completed & Graded Tests) for Tests Administered on 990524-27,0603,07-10 & 16.Eight of Fourteen Applicants Passed Exam | Job Performance Measure |
IR 05000413/1999005 | 24 September 1999 | Insp Repts 50-413/99-05 & 50-414/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Unanalyzed Condition High Radiation Area Stroke time Enforcement Discretion Missed surveillance Safeguards Contingency Plan |
IR 05000413/1999004 | 13 August 1999 | Insp Repts 50-413/99-04 & 50-414/99-04 on 990606-0717. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support | Time of Discovery Stroke time Enforcement Discretion Probabilistic Risk Assessment Commercial Grade Unidentified leakage |
ML20210H221 | 22 July 1999 | Notice of Violation from Insp on 990314-0424.Violation Noted:Sss Was Not Inoperable for Thirteen Days Because Electrical Breakers Associated with SSS Motor Control Ctr Were Mispositioned | Probabilistic Risk Assessment |
ML20209E283 | 1 July 1999 | Insp Repts 50-413/99-03 & 50-414/99-03 on 990425-0605. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support | Unanalyzed Condition High Radiation Area Grab sample Stroke time Past operability Enforcement Discretion Locked High Radiation Area Manual Operator Action |
IR 05000413/1999011 | 2 June 1999 | Insp Repts 50-413/99-11 & 50-414/99-11 on 990422-23 & 0503. No Violations Noted.Major Areas Inspected:Licensee Identified Frost & Ice Buildup Which Affected Unit 1 Ice Condenser Lower Inlet Doors | |
IR 05000413/1999002 | 20 May 1999 | Insp Repts 50-413/99-02 & 50-414/99-02 on 990314-0424.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Time of Discovery Fire Barrier Continuous fire watch Fire Protection Program Fire Watch Hourly Fire Watch Overspeed trip |
PNO-II-99-017, on 990515,indication of Main Generator Ground Fault Was Received While Performing Turbine Startup in Preparation for Placing Unit on Line.Licensee Is Conducting Investigation to Determine Actual Cause of Ground | 18 May 1999 | PNO-II-99-017:on 990515,indication of Main Generator Ground Fault Was Received While Performing Turbine Startup in Preparation for Placing Unit on Line.Licensee Is Conducting Investigation to Determine Actual Cause of Ground | |
ML20206U416 | 10 May 1999 | Insp Repts 50-413/99-10 & 50-414/99-10 on 990314-0424. Violation Being Considered for Escalated Enforcement Action Noted.Major Areas Inspected:Operations | Safe Shutdown |
PNO-II-99-015, on 990503,shutdown in Excess of 72 H Occurred. Licensee Is Still Conducting Investigation Into Cause of Main Generator Protection Lockout & Making Preparations to Inspect & Remove Any Excessive Fouling from Inside Afws | 5 May 1999 | PNO-II-99-015:on 990503,shutdown in Excess of 72 H Occurred. Licensee Is Still Conducting Investigation Into Cause of Main Generator Protection Lockout & Making Preparations to Inspect & Remove Any Excessive Fouling from Inside Afws | |
IR 05000413/1999001 | 6 April 1999 | Insp Repts 50-413/99-01 & 50-414/99-01 on 990124-0313. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Unanalyzed Condition Boric Acid Time of Discovery High Radiation Area Stroke time Enforcement Discretion Locked High Radiation Area |
ML20207A588 | 17 February 1999 | Notice of Violation from Insp on 981213-990123.Violation Noted:Licensee Made Change to Procedures as Described in Updated Final Safety Analysis Rept & Failed to Perform Written Safety Evaluation | |
IR 05000413/1998012 | 17 February 1999 | Insp Repts 50-413/98-12 & 50-414/98-12 on 981213-990123. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Time of Discovery Operability Determination Loss of condenser vacuum |
IR 05000413/1998011 | 11 January 1999 | Insp Repts 50-413/98-11 & 50-414/98-11 on 981101-1212.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Enforcement Discretion Missed surveillance Job Performance Measure Annual Radiological Environmental Operating Report Overspeed trip |
IR 05000413/1998015 | 4 January 1999 | Insp Repts 50-413/98-15 & 50-414/98-15 on 981102-06 & 16-20. No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program by Sampling Activities Defined in Nuclear Sys Directive 210,rev 1 | Non-Destructive Examination Past operability Nondestructive Examination Operability Determination Liquid penetrant |
IR 05000413/1998016 | 4 December 1998 | Insp Repts 50-413/98-16 & 50-414/98-16 on 980915-1101.No Violations Rept Encl.Major Areas Inspected:Licensee Maint, Surveillance & Engineering Programs Involving Unit 2 Ice Condenser | Unanalyzed Condition Foreign Material Exclusion |
IR 05000413/1998010 | 23 November 1998 | Insp Repts 50-413/98-10 & 50-414/98-10 on 980927-1031.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering & Plant Support | Stroke time Contraband Foreign Material Exclusion Maintenance Rule Program |
ML20155B382 | 19 October 1998 | Insp Repts 50-413/98-13 & 50-414/98-13 on 980807-0915. Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review Ice Condenser Related Problems,Which Led to Forced Shutdown | Past operability Condition Adverse to Quality Foreign Material Exclusion Downpower |
ML20154C430 | 14 September 1998 | Notice of Violation from Insp on 980705-0815.Violation Noted:Licensee Failed to Establish Adequate Surveillance Procedures | |
IR 05000413/1998008 | 14 September 1998 | Insp Repts 50-413/98-08 & 50-414/98-08 on 980705-0815. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering | Grab sample Stroke time Enforcement Discretion Missed surveillance Breakaway torque Pressure Boundary Leakage Grace period Manual Operator Action |
PNO-II-98-037A, on 980807,update Shutdown in Excess of 72 H Made.Licensee Has Cleaned & Satisfactorily Inspected IC Flow Channels.Licensee Identified Discrepancies in Bolting of IC Intermediate Deck Door Frames & Hinges.Conditions Addressed | 28 August 1998 | PNO-II-98-037A:on 980807,update Shutdown in Excess of 72 H Made.Licensee Has Cleaned & Satisfactorily Inspected IC Flow Channels.Licensee Identified Discrepancies in Bolting of IC Intermediate Deck Door Frames & Hinges.Conditions Addressed | |
IR 05000413/1998009 | 26 August 1998 | Insp Repts 50-413/98-09 & 50-414/98-09 on 980816-0826. Examples of Two Apparent Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support | High Radiation Area Non-Destructive Examination Stroke time Coatings Nondestructive Examination Emergency Lighting Locked High Radiation Area Condition Adverse to Quality Liquid penetrant |
PNO-II-98-037, on 980808,shutdown in Excess of 72 H Occurred. Licensee Inspected Approximately Half of Unit 2 Ice Condenser Bay Flow Channels from Intermediate Deck W/No Ice Obstructions in Excess of TS Limit Identified | 10 August 1998 | PNO-II-98-037:on 980808,shutdown in Excess of 72 H Occurred. Licensee Inspected Approximately Half of Unit 2 Ice Condenser Bay Flow Channels from Intermediate Deck W/No Ice Obstructions in Excess of TS Limit Identified | |
ML20236V735 | 27 July 1998 | Notice of Violation from Insp on 980524-0704.Violation Noted:Licensee Failed to Identify & Take Prompt C/A Following Unit 1 Upper Surge Tank over-temp Events on 960120,980111 & 0507 | |
IR 05000413/1998007 | 27 July 1998 | Insp Repts 50-413/98-07 & 50-414/98-07 on 980524-0704. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support,Including Physical Security | Safe Shutdown Boric Acid Time of Discovery Fire Barrier Stroke time Past operability Enforcement Discretion Emergency Lighting Condition Adverse to Quality Foreign Material Exclusion Operability Determination Through-Wall Leak Fire Protection Program Overspeed trip |
IR 05000413/1998005 | 22 June 1998 | Insp Repts 50-413/98-05 & 50-414/98-05 on 980412-0523.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Fitness for Duty Fire Barrier Enforcement Discretion Missed surveillance Biofouling Fire Protection Program Siren |
ML20236J747 | 11 June 1998 | Notice of Violation from Insp on 980222-0411.Violation Noted:Adminstrative & Surveillance Procedures Not Implemented as Evidenced by Listed Examples | |
IR 05000413/1998006 | 5 June 1998 | Insp Repts 50-413/98-06 & 50-414/98-06 on 980511-15. Violations Noted.Major Areas Inspected:Facts Surrounding Event Associated W/Degradation of CNS Unit Auxiliary Feedwater Sys During Rapid down-power on 980507 | Unanalyzed Condition Condition Adverse to Quality Operability Determination Downpower |
PNO-II-98-025, on 980507,AFW Sys Declared Inoperable.Licensee Isolated Valves 1CM-127 & 2CM-127 in Units 1 & 2, Respectively,To Prevent Recurrence Until Permanent Corrective Actions Can Be Developed | 11 May 1998 | PNO-II-98-025:on 980507,AFW Sys Declared Inoperable.Licensee Isolated Valves 1CM-127 & 2CM-127 in Units 1 & 2, Respectively,To Prevent Recurrence Until Permanent Corrective Actions Can Be Developed | Downpower |
IR 05000413/1998003 | 30 April 1998 | Insp Repts 50-413/98-03 & 50-414/98-03 on 980222-0411. Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Aspects of Licensee Operations, Maint,Engineering & Plant Support | Time of Discovery Past operability Operability Determination Exemption Request Operability Assessment |
IR 05000413/1998004 | 20 April 1998 | Insp Repts 50-413/98-04 & 50-414/98-04 on 980302-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Plant | Siren |
ML20217G566 | 23 March 1998 | Insp Repts 50-413/98-01 & 50-414/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operation,Maint, Engineering & Plant Support | Tornado-Generated Missile Process Control Program Operability Determination Fire Protection Program Fire Watch Scaffolding |
ML20217G555 | 23 March 1998 | Notice of Violation from Insp on 980111-0221.Violation Noted:Licensee Failed to Perform Written Safety Evaluation for Closing Valves 1CA-6 & 2CA-6 | |
IR 05000413/1998002 | 17 February 1998 | Partially Withheld Insp Repts 50-413/98-02 & 50-414/98-02 on 980112-13 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected:Plant Support,Including Malevolent Use of Vehicles at Plant | Safe Shutdown |
ML20203L630 | 9 February 1998 | Insp Repts 50-413/97-15 & 50-414/97-15 on 971123-980110. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support | Shutdown Margin High Radiation Area Time to boil Nondestructive Examination Locked High Radiation Area Foreign Material Exclusion Eddy Current Testing Operability Determination Exemption Request Liquid penetrant Coast down |
ML20203L625 | 9 February 1998 | Notice of Violation from Insp on 971123-980110.Violation Noted:Changes to Radiological Conditions in 1B Residual Heat Removal Pump Room Not Logged to Reflect Changes in Dress Requirements | |
ML20199L630 | 2 February 1998 | Notice of Violation from Insp & Exam on 971117-21 & 971201-19.Violation Noted:As of 971219,selected Officers from Site Security Force Had Not Been Retrained to Perform non-licensed Operator Emergency Tasks for Starting Ssf | Safe Shutdown |
PNO-II-97-066, on 971230,RCS Leakage Requiring Forced Unit Cooldown Occurred.No Radioactive Release Outside of Reactor Containment Facilities Due to Leakage.Licensee Informed States on Nc & Sc | 31 December 1997 | PNO-II-97-066:on 971230,RCS Leakage Requiring Forced Unit Cooldown Occurred.No Radioactive Release Outside of Reactor Containment Facilities Due to Leakage.Licensee Informed States on Nc & Sc | |
PNO-II-97-064, on 971229,inadvertent Safety Injection Occurred Due to Operators Failing to Perform Step Which Resulted in Cold Leg Injection Valve Being Left Open. Licensee Engineers Performing Evaluation | 29 December 1997 | PNO-II-97-064:on 971229,inadvertent Safety Injection Occurred Due to Operators Failing to Perform Step Which Resulted in Cold Leg Injection Valve Being Left Open. Licensee Engineers Performing Evaluation | |
ML20197F248 | 19 December 1997 | Notice of Violation from Insp on 971012-1122.Violation Noted:Licensee Failed to Follow Radiation Protection Procedures in That,Current Radiation Dose Rates Were Not on Vacuum Cleaner Label as Required | |
IR 05000414/1997008 | 19 December 1997 | Notice of Deviation from Insp on 971012-1122.Deviation Noted:On 971020,licensee Had Not Performed Alarm Set Point Adjustment Evaluation Discussed in Violation 50-414/97-08-01 | |
ML20197F286 | 19 December 1997 | Insp Repts 50-413/97-14 & 50-414/97-14 on 971012-1122. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Unanalyzed Condition Offsite Dose Calculation Manual Past operability Missed surveillance Operability Determination Exemption Request Scaffolding Coast down Overspeed trip |
ML20199G035 | 10 November 1997 | Notice of Violation from Insp on 970831-1011.Violations Noted:Licensee Failed to Follow Procedures for Security Badge Access Control as Evidenced.On 970909,security Failed to Destroy & Unassign Access Badge of Terminated Individual | |
IR 05000413/1997012 | 10 November 1997 | Insp Repts 50-413/97-12 & 50-414/97-12 on 970831-1011. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support as Well as Results of Announced Inspection by Regional Security Inspector | Foreign Material Exclusion Operability Determination Control of Heavy Loads |
ML20211L305 | 26 September 1997 | Notice of Violation from Insp on 970720-0830.Violation Noted:On 970727,technician Failed to Correctly Review Drawing Number CNEE-2792-01.02,connection Diagram,Main Steam Sys Terminal Cabinet 2SMTC1,rev 12 | |
IR 05000413/1997011 | 26 September 1997 | Insp Repts 50-413/97-11 & 50-414/97-11 on 970720-0830. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Packing leak Probabilistic Risk Assessment Stress corrosion cracking |
IR 05000413/1997010 | 11 September 1997 | Insp Repts 50-413/97-10 & 50-414/97-10 on 970623-0731.No Violations Noted.Major Areas Inspected:Licensee Calculations,Analysis & Other Engineering Documents | Safe Shutdown Stroke time Temporary Modification Operability Determination Backfit |
ML20210N734 | 18 August 1997 | Insp Repts 50-413/97-09 & 50-414/97-09 on 970608-0719. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Safe Shutdown Locked High Radiation Area Downpower |
ML20210N711 | 18 August 1997 | Notice of Violation from Insp on 970608-0719.Violation Noted:On 970424,operations Test Group Technician Failed to Open Valve 2NV-873 as Required by Step 2.2.3 of PT/2/A/4200/01C,resulting in Closed Test Vent Flowpath | Safe Shutdown Local Leak Rate Testing |