IR 05000413/1999005 | 24 September 1999 | Insp Repts 50-413/99-05 & 50-414/99-05 on 990718-0828. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Unanalyzed Condition High Radiation Area Stroke time Enforcement Discretion Missed surveillance Safeguards Contingency Plan |
IR 05000413/1999004 | 13 August 1999 | Insp Repts 50-413/99-04 & 50-414/99-04 on 990606-0717. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support | Time of Discovery Stroke time Enforcement Discretion Probabilistic Risk Assessment Commercial Grade Unidentified leakage |
ML20209E283 | 1 July 1999 | Insp Repts 50-413/99-03 & 50-414/99-03 on 990425-0605. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support | Unanalyzed Condition High Radiation Area Grab sample Stroke time Past operability Enforcement Discretion Locked High Radiation Area Manual Operator Action |
IR 05000413/1999011 | 2 June 1999 | Insp Repts 50-413/99-11 & 50-414/99-11 on 990422-23 & 0503. No Violations Noted.Major Areas Inspected:Licensee Identified Frost & Ice Buildup Which Affected Unit 1 Ice Condenser Lower Inlet Doors | |
IR 05000413/1999002 | 20 May 1999 | Insp Repts 50-413/99-02 & 50-414/99-02 on 990314-0424.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Time of Discovery Fire Barrier Continuous fire watch Fire Protection Program Fire Watch Hourly Fire Watch Overspeed trip |
ML20206U416 | 10 May 1999 | Insp Repts 50-413/99-10 & 50-414/99-10 on 990314-0424. Violation Being Considered for Escalated Enforcement Action Noted.Major Areas Inspected:Operations | Safe Shutdown |
IR 05000413/1999001 | 6 April 1999 | Insp Repts 50-413/99-01 & 50-414/99-01 on 990124-0313. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Unanalyzed Condition Boric Acid Time of Discovery High Radiation Area Stroke time Enforcement Discretion Locked High Radiation Area |
IR 05000413/1998012 | 17 February 1999 | Insp Repts 50-413/98-12 & 50-414/98-12 on 981213-990123. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Time of Discovery Operability Determination Loss of condenser vacuum |
IR 05000413/1998011 | 11 January 1999 | Insp Repts 50-413/98-11 & 50-414/98-11 on 981101-1212.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Enforcement Discretion Missed surveillance Job Performance Measure Annual Radiological Environmental Operating Report Overspeed trip |
IR 05000413/1998015 | 4 January 1999 | Insp Repts 50-413/98-15 & 50-414/98-15 on 981102-06 & 16-20. No Violations Noted.Major Areas Inspected:Licensee Corrective Action Program by Sampling Activities Defined in Nuclear Sys Directive 210,rev 1 | Non-Destructive Examination Past operability Nondestructive Examination Operability Determination Liquid penetrant |
IR 05000413/1998016 | 4 December 1998 | Insp Repts 50-413/98-16 & 50-414/98-16 on 980915-1101.No Violations Rept Encl.Major Areas Inspected:Licensee Maint, Surveillance & Engineering Programs Involving Unit 2 Ice Condenser | Unanalyzed Condition Foreign Material Exclusion |
IR 05000413/1998010 | 23 November 1998 | Insp Repts 50-413/98-10 & 50-414/98-10 on 980927-1031.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering & Plant Support | Stroke time Contraband Foreign Material Exclusion Maintenance Rule Program |
ML20155B382 | 19 October 1998 | Insp Repts 50-413/98-13 & 50-414/98-13 on 980807-0915. Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review Ice Condenser Related Problems,Which Led to Forced Shutdown | Past operability Condition Adverse to Quality Foreign Material Exclusion Downpower |
IR 05000413/1998008 | 14 September 1998 | Insp Repts 50-413/98-08 & 50-414/98-08 on 980705-0815. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering | Grab sample Stroke time Enforcement Discretion Missed surveillance Breakaway torque Pressure Boundary Leakage Grace period Manual Operator Action |
IR 05000413/1998009 | 26 August 1998 | Insp Repts 50-413/98-09 & 50-414/98-09 on 980816-0826. Examples of Two Apparent Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support | High Radiation Area Non-Destructive Examination Stroke time Coatings Nondestructive Examination Emergency Lighting Locked High Radiation Area Condition Adverse to Quality Liquid penetrant |
IR 05000413/1998007 | 27 July 1998 | Insp Repts 50-413/98-07 & 50-414/98-07 on 980524-0704. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support,Including Physical Security | Safe Shutdown Boric Acid Time of Discovery Fire Barrier Stroke time Past operability Enforcement Discretion Emergency Lighting Condition Adverse to Quality Foreign Material Exclusion Operability Determination Through-Wall Leak Fire Protection Program Overspeed trip |
IR 05000413/1998005 | 22 June 1998 | Insp Repts 50-413/98-05 & 50-414/98-05 on 980412-0523.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Fitness for Duty Fire Barrier Enforcement Discretion Missed surveillance Biofouling Fire Protection Program Siren |
IR 05000413/1998006 | 5 June 1998 | Insp Repts 50-413/98-06 & 50-414/98-06 on 980511-15. Violations Noted.Major Areas Inspected:Facts Surrounding Event Associated W/Degradation of CNS Unit Auxiliary Feedwater Sys During Rapid down-power on 980507 | Unanalyzed Condition Condition Adverse to Quality Operability Determination Downpower |
IR 05000413/1998003 | 30 April 1998 | Insp Repts 50-413/98-03 & 50-414/98-03 on 980222-0411. Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Aspects of Licensee Operations, Maint,Engineering & Plant Support | Time of Discovery Past operability Operability Determination Exemption Request Operability Assessment |
IR 05000413/1998004 | 20 April 1998 | Insp Repts 50-413/98-04 & 50-414/98-04 on 980302-06.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Plant | Siren |
ML20217G566 | 23 March 1998 | Insp Repts 50-413/98-01 & 50-414/98-01 on 980111-0221. Violations Noted.Major Areas Inspected:Operation,Maint, Engineering & Plant Support | Tornado-Generated Missile Process Control Program Operability Determination Fire Protection Program Fire Watch Scaffolding |
IR 05000413/1998002 | 17 February 1998 | Partially Withheld Insp Repts 50-413/98-02 & 50-414/98-02 on 980112-13 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected:Plant Support,Including Malevolent Use of Vehicles at Plant | Safe Shutdown |
ML20203L630 | 9 February 1998 | Insp Repts 50-413/97-15 & 50-414/97-15 on 971123-980110. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support | Shutdown Margin High Radiation Area Time to boil Nondestructive Examination Locked High Radiation Area Foreign Material Exclusion Eddy Current Testing Operability Determination Exemption Request Liquid penetrant Coast down |
ML20197F286 | 19 December 1997 | Insp Repts 50-413/97-14 & 50-414/97-14 on 971012-1122. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Unanalyzed Condition Offsite Dose Calculation Manual Past operability Missed surveillance Operability Determination Exemption Request Scaffolding Coast down Overspeed trip |
IR 05000413/1997012 | 10 November 1997 | Insp Repts 50-413/97-12 & 50-414/97-12 on 970831-1011. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support as Well as Results of Announced Inspection by Regional Security Inspector | Foreign Material Exclusion Operability Determination Control of Heavy Loads |
IR 05000413/1997011 | 26 September 1997 | Insp Repts 50-413/97-11 & 50-414/97-11 on 970720-0830. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Packing leak Probabilistic Risk Assessment Stress corrosion cracking |
IR 05000413/1997010 | 11 September 1997 | Insp Repts 50-413/97-10 & 50-414/97-10 on 970623-0731.No Violations Noted.Major Areas Inspected:Licensee Calculations,Analysis & Other Engineering Documents | Safe Shutdown Stroke time Temporary Modification Operability Determination Backfit |
ML20210N734 | 18 August 1997 | Insp Repts 50-413/97-09 & 50-414/97-09 on 970608-0719. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Safe Shutdown Locked High Radiation Area Downpower |
ML20149F929 | 7 July 1997 | Insp Repts 50-413/97-08 & 50-414/97-08 on 970427-0607. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support | Time of Discovery Fitness for Duty Stroke time Past operability Locked High Radiation Area Operability Determination |
ML20148F944 | 23 May 1997 | Insp Repts 50-413/97-07 & 50-414/97-07 on 970323-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Boric Acid Fire Barrier Nondestructive Examination Emergency Lighting Foreign Material Exclusion Flow Accelerated Corrosion Eddy Current Testing Liquid penetrant Continuous fire watch Fire Protection Program Fire Watch Hourly Fire Watch Dissimilar Metal Weld |
IR 05000413/1997005 | 21 April 1997 | Integrated Insp Repts 50-413/97-05 & 50-414/97-05 on 970216- 0322.No Violations Identified.Major Areas Inspected:Maint, Operations,Engineering & Plant Support | Offsite Dose Calculation Manual Temporary Modification Emergency Lighting Manual Operator Action |
IR 05000413/1997006 | 4 April 1997 | Insp Repts 50-413/97-06 & 50-414/97-06 on 970317-20.No Violations Noted.Major Areas Inspected:Conduct of Security & Safeguards Activities,Plant Support & Status of Security Facilities & Equipment | |
ML20140B763 | 17 March 1997 | Insp Repts 50-413/97-03 & 50-414/97-03 on 970112-0215. Violations Noted.Major Areas Inspected:Licensee Operation, Maint,Engineering & Plant Support | Hot Short Safe Shutdown Boric Acid Packing leak Non-Destructive Examination Commercial Grade Dedication Anchor Darling Operability Determination |
IR 05000413/1996019 | 21 February 1997 | Insp Repts 50-413/96-19 & 50-414/96-19 on 961007, 961127, & 970206.Violation Noted.Major Areas inspected:in-office Review of Licensee Describing Changes to CNS UFSAR Re Lack of Circuit Breaker Coordination for 600-Vac | Probabilistic Risk Assessment |
IR 05000413/1996020 | 10 February 1997 | Insp Repts 50-413/96-20 & 50-414/96-20 on 961201-970111.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support | Boric Acid Operability Determination Unidentified leakage |
IR 05000413/1997004 | 31 January 1997 | Insp Repts 50-413/97-04 & 50-414/97-04 on 970106-23.No Violations Noted.Major Areas Inspected:Operations & Engineering | |
IR 05000413/1997002 | 31 January 1997 | Insp Repts 50-413/97-02 & 50-414/97-02 on 970106-10.No Violations Noted.Major Areas Inspected:Plant Support | |
IR 05000413/1996018 | 30 December 1996 | Insp Repts 50-413/96-18 & 50-414/96-18 on 961020-1130.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering | Safe Shutdown Boric Acid Nondestructive Examination Job Performance Measure Offsite Circuit Grace period Downpower Thermography |
ML20135C260 | 15 November 1996 | Insp Repts 50-413/96-16 & 50-414/96-16 on 960908-1019.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Fire Barrier Past operability Fire Watch Inattentive |
IR 05000413/1996015 | 7 November 1996 | Insp Repts 50-413/96-15 & 50-414/96-15 on 960901-1012.No Violations Noted.Major Areas Inspected:Engineering & Plant Support | Hydrostatic Nondestructive Examination |
IR 05000413/1996017 | 1 November 1996 | Insp Repts 50-413/96-17 & 50-414/96-17 on 960930-1004.No Violations Noted.Major Areas Inspected:Plant Support | Safeguards Contingency Plan |
ML20128R095 | 7 October 1996 | Insp Repts 50-413/96-13 & 50-414/96-13 on 960728-0907. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Plant Status | Safe Shutdown Time of Discovery High Radiation Area Non-Destructive Examination Stroke time Tornado Missile Protection Foreign Material Exclusion Operability Determination |
ML20128J039 | 30 September 1996 | Insp Repts 50-413/96-12 & 50-414/96-12 on 960804-31. Violations Noted.Major Areas Inspected:Engineering, Summary of Plant Status & Observations & Findings | Nondestructive Examination Foreign Material Exclusion Liquid penetrant |
IR 05000413/1994014 | 3 June 1994 | Insp Repts 50-413/94-14 & 50-414/94-14 on 940509-20.No Violations Noted.Major Areas Inspected:Isi & Flow Assisted Corrosion | Coatings Nondestructive Examination VT-2 Condition Adverse to Quality Flow Accelerated Corrosion Liquid penetrant |
IR 05000269/1993032 | 6 January 1994 | Insp Repts 50-269/93-32,50-270/93-32,50-287/93-32, 50-369/93-31,50-370/93-31,50-413/93-35 & 50-414,respectively on 931213-17.Violations Noted.Major Areas Inpected:Licensee Safeguards Info Program to folow-up on Licensee Repts | Fitness for Duty |
IR 05000413/1993032 | 30 December 1993 | Insp Repts 50-413/93-32 & 50-414/93-32 on 931117-19 & 1129-1203.Violations Noted.Major Areas Inspected:Observation of Eddy Current (ET) Exam of SG Tubes,Inservice Activities Including Surface & Volumetric Exams,Review of Radiographs | Nondestructive Examination Stress corrosion cracking Liquid penetrant |
IR 05000413/1993033 | 23 December 1993 | Insp Repts 50-413/93-33 & 50-414/93-33 on 931129-1203.No Violations Noted.Major Areas Inspected:Isi of Pipe Supports & Snubbers & TS Surveillance of Snubbers | |
IR 05000413/1993031 | 22 December 1993 | Insp Repts 50-413/93-31 & 50-414/93-31 on 931107-1204.No Violations Noted.Major Areas Inspected:Plant Operations, Maintenance,Engineering,Plant Support & follow-up of Previously Identifed Items | Systematic Assessment of Licensee Performance Exclusive Use |
IR 05000413/1993029 | 12 December 1993 | Insp Repts 50-413/93-29 & 50-414/93-29 on 931115-19.No Violations Noted.Major Areas Inspected:Occupational Radiation Safety,Organization & Mgt Controls,Training & Qualification,Audits & Appraisals | High Radiation Area Process Control Program |
IR 05000413/1993028 | 10 December 1993 | Insp Repts 50-413/93-28 & 50-414/93-28 on 931101-05.No Violations Noted.Deviation Noted.Major Areas Inspected: Adequacy of Licensee Programs,Procedures & Supporting Documentation for Implementation of Station Blackout Rule | Safe Shutdown High winds Emergency Lighting Battery sizing Earthquake Unidentified leakage |