Insp Repts 50-280/91-22,50-281/91-22,50-338/91-18 & 50-339/91-18 on 910731 & 0801-02.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Pipe Wall Thinning Insp & Replacement ProgramML20128Q404 |
Person / Time |
---|
Site: |
Surry, North Anna ![Dominion icon.png](/w/images/b/b0/Dominion_icon.png) |
---|
Issue date: |
08/23/1991 |
---|
From: |
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
---|
To: |
|
---|
Shared Package |
---|
ML20128Q380 |
List: |
---|
References |
---|
50-280-91-22, 50-281-91-22, 50-338-91-18, 50-339-91-18, NUDOCS 9610210055 |
Download: ML20128Q404 (6) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000338/19990031999-07-0202 July 1999 Insp Repts 50-338/99-03 & 50-339/99-03 on 990425-0605.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19990011999-04-12012 April 1999 Insp Repts 50-338/99-01 & 50-339/99-01 on 990131-0313. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.In Addition,Results of Insp by Region Based Fire Protection Specialist Encl IR 05000338/19980111999-03-0101 March 1999 Insp Repts 50-338/98-11 & 50-339/98-11 on 981220-990130.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000338/19980101999-01-14014 January 1999 Insp Repts 50-338/98-10 & 50-339/98-10 on 981108-1219.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20196H4131998-11-0505 November 1998 Insp Repts 50-338/98-05 & 50-339/98-05 on 980713-31 & 0921- 25.Violation Noted.Major Areas Inspected:Review of Licensee Calculations,Analysis,Performance Test Procedures & Other Engineering Documents Used to Support Design & Performance IR 05000338/19980071998-08-18018 August 1998 Insp Repts 50-338/98-07 & 50-339/98-07 on 980720-23.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise for North Anna Nuclear Station IR 05000280/19980051998-07-13013 July 1998 Insp Repts 50-280/98-05 & 50-281/98-05 on 980503-0613.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20216H6711998-04-0303 April 1998 Insp Repts 50-338/98-01,50-338/98-01 & 72-0016/98-01 on 980125-0307.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000338/19970111998-01-12012 January 1998 Insp Repts 50-338/97-11,50-339/97-11 & 72-0016/97-04 on 971102-1213.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000280/19970111997-10-0707 October 1997 Partially Withheld Insp Repts 50-280/97-11 & 50-281/97-11 on 970924 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specialist IR 05000338/19970101997-10-0707 October 1997 Partially Withheld Insp Repts 50-338/97-10 & 50-339/97-10 on 970922-23 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specalist IR 05000338/19970041997-07-21021 July 1997 Insp Repts 50-338/97-04 & 50-339/97-04 on 970518-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19970051997-07-15015 July 1997 Insp Repts 50-338/97-05 & 50-339/97-05 on 970616-20.No Violations Noted.Major Areas Inspected:Plant Support ML20140F2651997-06-0606 June 1997 Insp Repts 50-338/97-03 & 50-339/97-03 on 970406-0517. Non-cited Violation Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000338/19970021997-05-0505 May 1997 Insp Repts 50-338/97-02 & 50-339/97-02 on 970223-0405.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20137F7661997-03-21021 March 1997 Insp Repts 50-338/97-01 & 50-339/97-01 on 970112-0222. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19960131997-02-0707 February 1997 Insp Repts 50-338/96-13 & 50-339/96-13 on 961208-970111.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20133J1991997-01-0606 January 1997 Insp Repts 50-338/96-12 & 50-339/96-12 on 961102-1207. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000338/19960101996-12-0202 December 1996 Insp Repts 50-338/96-10 & 50-339/96-10 on 960922-1102. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000338/19960111996-11-15015 November 1996 Insp Repts 50-338/96-11 & 50-339/96-11 on 961014-18.No Violations Noted.Major Areas Inspected:Plant Support ML20134G9071996-10-21021 October 1996 Insp Repts 50-338/96-09 & 50-339/96-09 on 960811-0921. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20128K0591996-09-30030 September 1996 Insp Repts 50-338/96-08 & 50-339/96-08 on 960812-16.No Violations Noted.Major Areas Inspected:Cr Simulator,Tsc,Osc, EOF, & Joint Info Ctr IR 05000338/19960071996-09-0909 September 1996 Insp Repts 50-338/96-07 & 50-339/96-07 on 960810.Violations Noted.Major Areas Inspected:Licensee Operations,Engineers, Maint & Plant Support IR 05000338/19940291994-12-29029 December 1994 Partially Withheld Insp Repts 50-338/94-29 & 50-339/94-29 on 941128-1202 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors IR 05000338/19930291994-01-12012 January 1994 Insp Repts 50-338/93-29 & 50-339/93-29 on Stated Date.No Violations Noted.Major Areas Inspected:Plant Status,Ler Followup,Safety Verification,Maintenance Observation, Surveillance Observation & Cold Weather Preparations ML20059B2881993-12-14014 December 1993 Insp Repts 50-338/93-27 & 50-339/93-27 on 931017-1120. Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation & Surveillance Observation IR 05000338/19930241993-11-15015 November 1993 Insp Repts 50-338/93-24 & 50-339/93-24 on 930919-1016.No Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation, Surveillance Observation & LER Followup IR 05000338/19930281993-10-29029 October 1993 Insp Repts 50-338/93-28 & 50-339/93-28 on 931014-20. Violations Noted.Major Areas Inspected:Circumstances Surrounding Unit 2 High Head Safety Injection Subsystem Not Meeting TS Min Flow Requirement on 931014 IR 05000338/19930261993-10-27027 October 1993 Insp Repts 50-338/93-26 & 50-339/93-26 on 930927-1001.No Violations or Deviations Noted.Major Areas Inspected: Licensee Radiation Protection Program,Involving Review of HP Activities Primarily Associated W/Unit 2 Refueling Outage IR 05000338/19930211993-10-20020 October 1993 Insp Repts 50-338/93-21 & 50-339/93-21 on 930920-24.No Violations Noted.Major Areas Inspected:Organization of Chemistry Dept & Units Responsible for Handling & Shipping of Radioactive Matl & Plant Water Chemistry IR 05000338/19930231993-10-15015 October 1993 Insp Repts 50-338/93-23 & 50-339/93-23 on 930822-0918.No Violations Noted.Major Areas Inspected:Plant Status, Operational Verification,Maint Observation,Training & Action on Previous Insp Items IR 05000338/19930251993-10-13013 October 1993 Insp Repts 50-338/93-25 & 50-339/93-25 on 930914-17.No Violations Noted.Major Areas Inspected:Eddy Current Exam of Steam Generator Tubes IR 05000338/19930201993-09-17017 September 1993 Insp Repts 50-338/93-20 & 50-339/93-20 on 930718-0821.No Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maint Observation, Surveillance Observation & Action on Previous Insp Items ML20056E8651993-08-0404 August 1993 Insp Repts 50-338/93-19 & 50-339/93-19 on 930620-0717. Violations Noted.Major Areas Inspected:Operational Safety Verification,Maint Observation,Plant Status & Surveillance Observation ML20056D1671993-07-13013 July 1993 Insp Repts 50-338/93-18 & 50-339/93-18 on 930509-0619. Violations Noted.Major Areas Inspected:Examinations of Procedures & Representative Records,Interviews W/Personnel & Observaton of Activities in Progress IR 05000338/19930091993-03-24024 March 1993 Insp Repts 50-338/93-09 & 50-339/93-09 on 930208-12 & 22-55. No Violations Noted.Major Areas Inspected:Fitup,Preheat & Fabrication of Field Welds,Weld Repairs,Nde & Review of Fabrication Records IR 05000338/19930081993-03-15015 March 1993 Insp Repts 50-338/93-08 & 50-339/93-08 on 930117-0220. Violation Noted.Major Areas Inspected:Plant Status,License Event Rept & Surveillance Observation IR 05000338/19930011993-03-12012 March 1993 Insp Repts 50-338/93-01 & 50-339/93-01 on 930115-0211.Two Noncited Violations Identified.Major Areas Inspected:Program Organization & Mgt Controls,Hp Technician Training & Operational & Administrative Controls IR 05000338/19930061993-02-11011 February 1993 Partially Withheld Insp Repts 50-338/93-06 & 50-339/93-06 on 930125-29.No Violations Noted.Major Areas Inspected: Physical Security Program,Including Protected Vital Area Barriers.Portions Withheld (Ref 10CFR2.790) IR 05000338/19930051993-02-0505 February 1993 Insp Repts 50-338/93-05 & 50-339/93-05 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Control of Heavy Loads in Containment & Crane Insps to Be Performed During SG Replacement Project IR 05000338/19930021993-02-0303 February 1993 Insp Repts 50-338/93-02 & 50-339/93-02 on 930104-08.No Violations Noted.Major Areas Inspected:Design Changes & Mod,Engineering Support Activities & Licensee Event Rept Followup IR 05000338/19920291993-01-13013 January 1993 Insp Repts 50-338/92-29 & 50-339/92-29 on 921122-1219.No Violations Noted.Major Areas Inspected:Operations,Maint, Minor Mods,Surveillances & Action on Previous Insp Findings IR 05000338/19920261992-12-31031 December 1992 Insp Repts 50-338/92-26 & 50-339/92-26 on 921130-1204.No Violations Noted.Major Areas Inspected:Organization & Staffing,Radiation Protection Training,Procedures & Work Controls ML20126E3431992-12-23023 December 1992 Insp Repts 50-338/92-30 & 50-339/92-30 on 921130-1204. Violations Noted.Major Areas Inspected:Mgt Support & Security Program Plans,Protected & Vital Area Barriers, Detection & Power Supply.Rept Partially Withheld IR 05000338/19920311992-12-17017 December 1992 Insp Repts 50-338/92-31 & 50-339/92-31 on 921207-10.No Violations or Deviations Noted.Major Areas Inspected: Emergency Operating Procedure & Abnormal Operating Procedure Followup IR 05000338/19920271992-12-16016 December 1992 Insp Repts 50-338/92-27 & 50-339/92-27 on 921116-20.No Violations or Deviations Noted.Major Areas Inspected:Primary Water Plant Chemistry,Confirmatory Measurements of non-radiological Samples & Radiological REMP IR 05000338/19920281992-12-15015 December 1992 Insp Repts 50-338/92-28 & 50-339/92-28 on 921116-20.No Violations or Deviations Noted.Major Areas Inspected:To Observe Certain Activities in Preparation for SG Replacement Project in Unit 1 & to Review Approved Welding Procedures IR 05000338/19920231992-12-11011 December 1992 Insp Repts 50-338/92-23 & 50-339/92-23 on 921018-1121.No Violations or Deviations Noted.Major Areas Inspected:Minor Mods,Operations,Maintenance,Surveillance,Esf Walkdown,Ler Followup & Actions on Previous Insp Findings IR 05000338/19920251992-11-25025 November 1992 Insp Repts 50-338/92-25 & 50-339/92-25 on 921102-06.No Violations Noted.Weaknesses Noted Re Heavy Loads Program. Major Areas inspected:post-refueling Startup Tests,Routine Surveillance of Core Performance & Control of Heavy Loads IR 05000280/19910221991-08-23023 August 1991 Insp Repts 50-280/91-22,50-281/91-22,50-338/91-18 & 50-339/91-18 on 910731 & 0801-02.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Pipe Wall Thinning Insp & Replacement Program 1999-07-02
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000338/19990031999-07-0202 July 1999 Insp Repts 50-338/99-03 & 50-339/99-03 on 990425-0605.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19990011999-04-12012 April 1999 Insp Repts 50-338/99-01 & 50-339/99-01 on 990131-0313. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.In Addition,Results of Insp by Region Based Fire Protection Specialist Encl IR 05000338/19980111999-03-0101 March 1999 Insp Repts 50-338/98-11 & 50-339/98-11 on 981220-990130.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000338/19980101999-01-14014 January 1999 Insp Repts 50-338/98-10 & 50-339/98-10 on 981108-1219.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20196H4131998-11-0505 November 1998 Insp Repts 50-338/98-05 & 50-339/98-05 on 980713-31 & 0921- 25.Violation Noted.Major Areas Inspected:Review of Licensee Calculations,Analysis,Performance Test Procedures & Other Engineering Documents Used to Support Design & Performance IR 05000338/19980071998-08-18018 August 1998 Insp Repts 50-338/98-07 & 50-339/98-07 on 980720-23.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise for North Anna Nuclear Station IR 05000280/19980051998-07-13013 July 1998 Insp Repts 50-280/98-05 & 50-281/98-05 on 980503-0613.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20216H6711998-04-0303 April 1998 Insp Repts 50-338/98-01,50-338/98-01 & 72-0016/98-01 on 980125-0307.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000338/19970111998-01-12012 January 1998 Insp Repts 50-338/97-11,50-339/97-11 & 72-0016/97-04 on 971102-1213.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000280/19970111997-10-0707 October 1997 Partially Withheld Insp Repts 50-280/97-11 & 50-281/97-11 on 970924 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specialist IR 05000338/19970101997-10-0707 October 1997 Partially Withheld Insp Repts 50-338/97-10 & 50-339/97-10 on 970922-23 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specalist IR 05000338/19970041997-07-21021 July 1997 Insp Repts 50-338/97-04 & 50-339/97-04 on 970518-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19970051997-07-15015 July 1997 Insp Repts 50-338/97-05 & 50-339/97-05 on 970616-20.No Violations Noted.Major Areas Inspected:Plant Support ML20140F2651997-06-0606 June 1997 Insp Repts 50-338/97-03 & 50-339/97-03 on 970406-0517. Non-cited Violation Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000338/19970021997-05-0505 May 1997 Insp Repts 50-338/97-02 & 50-339/97-02 on 970223-0405.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20137F7661997-03-21021 March 1997 Insp Repts 50-338/97-01 & 50-339/97-01 on 970112-0222. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19960131997-02-0707 February 1997 Insp Repts 50-338/96-13 & 50-339/96-13 on 961208-970111.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20133J1991997-01-0606 January 1997 Insp Repts 50-338/96-12 & 50-339/96-12 on 961102-1207. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000338/19960101996-12-0202 December 1996 Insp Repts 50-338/96-10 & 50-339/96-10 on 960922-1102. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000338/19960111996-11-15015 November 1996 Insp Repts 50-338/96-11 & 50-339/96-11 on 961014-18.No Violations Noted.Major Areas Inspected:Plant Support ML20134G9071996-10-21021 October 1996 Insp Repts 50-338/96-09 & 50-339/96-09 on 960811-0921. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20128K0591996-09-30030 September 1996 Insp Repts 50-338/96-08 & 50-339/96-08 on 960812-16.No Violations Noted.Major Areas Inspected:Cr Simulator,Tsc,Osc, EOF, & Joint Info Ctr IR 05000338/19960071996-09-0909 September 1996 Insp Repts 50-338/96-07 & 50-339/96-07 on 960810.Violations Noted.Major Areas Inspected:Licensee Operations,Engineers, Maint & Plant Support IR 05000338/19940291994-12-29029 December 1994 Partially Withheld Insp Repts 50-338/94-29 & 50-339/94-29 on 941128-1202 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors IR 05000338/19930291994-01-12012 January 1994 Insp Repts 50-338/93-29 & 50-339/93-29 on Stated Date.No Violations Noted.Major Areas Inspected:Plant Status,Ler Followup,Safety Verification,Maintenance Observation, Surveillance Observation & Cold Weather Preparations ML20059B2881993-12-14014 December 1993 Insp Repts 50-338/93-27 & 50-339/93-27 on 931017-1120. Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation & Surveillance Observation IR 05000338/19930241993-11-15015 November 1993 Insp Repts 50-338/93-24 & 50-339/93-24 on 930919-1016.No Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation, Surveillance Observation & LER Followup IR 05000338/19930281993-10-29029 October 1993 Insp Repts 50-338/93-28 & 50-339/93-28 on 931014-20. Violations Noted.Major Areas Inspected:Circumstances Surrounding Unit 2 High Head Safety Injection Subsystem Not Meeting TS Min Flow Requirement on 931014 IR 05000338/19930261993-10-27027 October 1993 Insp Repts 50-338/93-26 & 50-339/93-26 on 930927-1001.No Violations or Deviations Noted.Major Areas Inspected: Licensee Radiation Protection Program,Involving Review of HP Activities Primarily Associated W/Unit 2 Refueling Outage IR 05000338/19930211993-10-20020 October 1993 Insp Repts 50-338/93-21 & 50-339/93-21 on 930920-24.No Violations Noted.Major Areas Inspected:Organization of Chemistry Dept & Units Responsible for Handling & Shipping of Radioactive Matl & Plant Water Chemistry IR 05000338/19930231993-10-15015 October 1993 Insp Repts 50-338/93-23 & 50-339/93-23 on 930822-0918.No Violations Noted.Major Areas Inspected:Plant Status, Operational Verification,Maint Observation,Training & Action on Previous Insp Items IR 05000338/19930251993-10-13013 October 1993 Insp Repts 50-338/93-25 & 50-339/93-25 on 930914-17.No Violations Noted.Major Areas Inspected:Eddy Current Exam of Steam Generator Tubes IR 05000338/19930201993-09-17017 September 1993 Insp Repts 50-338/93-20 & 50-339/93-20 on 930718-0821.No Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maint Observation, Surveillance Observation & Action on Previous Insp Items ML20056E8651993-08-0404 August 1993 Insp Repts 50-338/93-19 & 50-339/93-19 on 930620-0717. Violations Noted.Major Areas Inspected:Operational Safety Verification,Maint Observation,Plant Status & Surveillance Observation ML20056D1671993-07-13013 July 1993 Insp Repts 50-338/93-18 & 50-339/93-18 on 930509-0619. Violations Noted.Major Areas Inspected:Examinations of Procedures & Representative Records,Interviews W/Personnel & Observaton of Activities in Progress IR 05000338/19930091993-03-24024 March 1993 Insp Repts 50-338/93-09 & 50-339/93-09 on 930208-12 & 22-55. No Violations Noted.Major Areas Inspected:Fitup,Preheat & Fabrication of Field Welds,Weld Repairs,Nde & Review of Fabrication Records IR 05000338/19930081993-03-15015 March 1993 Insp Repts 50-338/93-08 & 50-339/93-08 on 930117-0220. Violation Noted.Major Areas Inspected:Plant Status,License Event Rept & Surveillance Observation IR 05000338/19930011993-03-12012 March 1993 Insp Repts 50-338/93-01 & 50-339/93-01 on 930115-0211.Two Noncited Violations Identified.Major Areas Inspected:Program Organization & Mgt Controls,Hp Technician Training & Operational & Administrative Controls IR 05000338/19930061993-02-11011 February 1993 Partially Withheld Insp Repts 50-338/93-06 & 50-339/93-06 on 930125-29.No Violations Noted.Major Areas Inspected: Physical Security Program,Including Protected Vital Area Barriers.Portions Withheld (Ref 10CFR2.790) IR 05000338/19930051993-02-0505 February 1993 Insp Repts 50-338/93-05 & 50-339/93-05 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Control of Heavy Loads in Containment & Crane Insps to Be Performed During SG Replacement Project IR 05000338/19930021993-02-0303 February 1993 Insp Repts 50-338/93-02 & 50-339/93-02 on 930104-08.No Violations Noted.Major Areas Inspected:Design Changes & Mod,Engineering Support Activities & Licensee Event Rept Followup IR 05000338/19920291993-01-13013 January 1993 Insp Repts 50-338/92-29 & 50-339/92-29 on 921122-1219.No Violations Noted.Major Areas Inspected:Operations,Maint, Minor Mods,Surveillances & Action on Previous Insp Findings IR 05000338/19920261992-12-31031 December 1992 Insp Repts 50-338/92-26 & 50-339/92-26 on 921130-1204.No Violations Noted.Major Areas Inspected:Organization & Staffing,Radiation Protection Training,Procedures & Work Controls ML20126E3431992-12-23023 December 1992 Insp Repts 50-338/92-30 & 50-339/92-30 on 921130-1204. Violations Noted.Major Areas Inspected:Mgt Support & Security Program Plans,Protected & Vital Area Barriers, Detection & Power Supply.Rept Partially Withheld IR 05000338/19920311992-12-17017 December 1992 Insp Repts 50-338/92-31 & 50-339/92-31 on 921207-10.No Violations or Deviations Noted.Major Areas Inspected: Emergency Operating Procedure & Abnormal Operating Procedure Followup IR 05000338/19920271992-12-16016 December 1992 Insp Repts 50-338/92-27 & 50-339/92-27 on 921116-20.No Violations or Deviations Noted.Major Areas Inspected:Primary Water Plant Chemistry,Confirmatory Measurements of non-radiological Samples & Radiological REMP IR 05000338/19920281992-12-15015 December 1992 Insp Repts 50-338/92-28 & 50-339/92-28 on 921116-20.No Violations or Deviations Noted.Major Areas Inspected:To Observe Certain Activities in Preparation for SG Replacement Project in Unit 1 & to Review Approved Welding Procedures IR 05000338/19920231992-12-11011 December 1992 Insp Repts 50-338/92-23 & 50-339/92-23 on 921018-1121.No Violations or Deviations Noted.Major Areas Inspected:Minor Mods,Operations,Maintenance,Surveillance,Esf Walkdown,Ler Followup & Actions on Previous Insp Findings IR 05000338/19920251992-11-25025 November 1992 Insp Repts 50-338/92-25 & 50-339/92-25 on 921102-06.No Violations Noted.Weaknesses Noted Re Heavy Loads Program. Major Areas inspected:post-refueling Startup Tests,Routine Surveillance of Core Performance & Control of Heavy Loads IR 05000280/19910221991-08-23023 August 1991 Insp Repts 50-280/91-22,50-281/91-22,50-338/91-18 & 50-339/91-18 on 910731 & 0801-02.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Pipe Wall Thinning Insp & Replacement Program 1999-07-02
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000280/19993021999-09-0808 September 1999 NRC Operator Licensing Retake Exam Repts 50-280/99-302 & 50-281/99-302 for Retake Exam Tests Administered on 990824. Exam Results:One SRO Candidate Received Part B re-take Operating Exam & Passed IR 05000338/19990031999-07-0202 July 1999 Insp Repts 50-338/99-03 & 50-339/99-03 on 990425-0605.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000280/19993011999-05-14014 May 1999 NRC Operator Licensing Exam Repts 50-280/99-301 & 50-281/99-301 (Including Completed & Graded Exams) for Tests Administered on 990329-0401 & 990412-15 IR 05000338/19990011999-04-12012 April 1999 Insp Repts 50-338/99-01 & 50-339/99-01 on 990131-0313. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.In Addition,Results of Insp by Region Based Fire Protection Specialist Encl IR 05000338/19980111999-03-0101 March 1999 Insp Repts 50-338/98-11 & 50-339/98-11 on 981220-990130.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000338/19980101999-01-14014 January 1999 Insp Repts 50-338/98-10 & 50-339/98-10 on 981108-1219.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20196H4131998-11-0505 November 1998 Insp Repts 50-338/98-05 & 50-339/98-05 on 980713-31 & 0921- 25.Violation Noted.Major Areas Inspected:Review of Licensee Calculations,Analysis,Performance Test Procedures & Other Engineering Documents Used to Support Design & Performance ML20196H4081998-11-0505 November 1998 Notice of Violation from Insp on 980713-31 & 0921-25. Violation Noted:As of 980712,AFW Pipe Supports Were Not Constructed IAW Details Shown on Design Drawings as Listed ML20155B0671998-10-0202 October 1998 NRC Operator Licensing Exam Repts 50-338/98-301 & 50-339/98-301 (Including Completed & Graded Tests) for Tests Administered on 980817-21 & 31-0903 IR 05000338/19980071998-08-18018 August 1998 Insp Repts 50-338/98-07 & 50-339/98-07 on 980720-23.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial EP Exercise for North Anna Nuclear Station IR 05000280/19980051998-07-13013 July 1998 Insp Repts 50-280/98-05 & 50-281/98-05 on 980503-0613.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20216H6711998-04-0303 April 1998 Insp Repts 50-338/98-01,50-338/98-01 & 72-0016/98-01 on 980125-0307.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000338/19970111998-01-12012 January 1998 Insp Repts 50-338/97-11,50-339/97-11 & 72-0016/97-04 on 971102-1213.No Violations Noted.Major Areas Inspected: Operations,Engineering,Maintenance & Plant Support IR 05000280/19970111997-10-0707 October 1997 Partially Withheld Insp Repts 50-280/97-11 & 50-281/97-11 on 970924 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specialist IR 05000338/19970101997-10-0707 October 1997 Partially Withheld Insp Repts 50-338/97-10 & 50-339/97-10 on 970922-23 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Plant Support by Regional Safeguards Specalist ML20216B2581997-08-29029 August 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Licensee Failed to Monitor Performance & Establish Goals Commensurate W/Safety for Emergency Switch Gear Heating Ventilation IR 05000338/19970041997-07-21021 July 1997 Insp Repts 50-338/97-04 & 50-339/97-04 on 970518-0621.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000338/19970051997-07-15015 July 1997 Insp Repts 50-338/97-05 & 50-339/97-05 on 970616-20.No Violations Noted.Major Areas Inspected:Plant Support ML20140F2651997-06-0606 June 1997 Insp Repts 50-338/97-03 & 50-339/97-03 on 970406-0517. Non-cited Violation Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000338/19970021997-05-0505 May 1997 Insp Repts 50-338/97-02 & 50-339/97-02 on 970223-0405.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20148B6541997-05-0505 May 1997 Notice of Violation from Insp on 970223-0405.Violation Noted:Operators Failed to Verify That Unit 1 & 2 RCPs 1 Seal Leakoffs & Unit 2 Nr 46 Nuclear Power Range Chart Recorders Were Operational ML20137F7661997-03-21021 March 1997 Insp Repts 50-338/97-01 & 50-339/97-01 on 970112-0222. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20137F7411997-03-21021 March 1997 Notice of Violation from Insp on 970112-0222.Violation Noted:As of 970213,radiation Monitors Installed in Fuel Handling & Storage Locations,Did Not Provide Full Coverage for Area Used for New Fuel Receipt IR 05000338/19970991997-02-21021 February 1997 SALP Repts 50-338/97-99 & 50-339/97-99 for 941225-970111 IR 05000338/19960131997-02-0707 February 1997 Insp Repts 50-338/96-13 & 50-339/96-13 on 961208-970111.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20133G8881997-01-0606 January 1997 Notice of Violation from Insp on 961103-1207.Violation Noted:Licensee Failed to Ensure That Safeguards Area Walls Met Design Basis for Containing Pump Seal Leakage Described in Updated Final Safety Analysis Rept Section 15.4.1.8 ML20133J1991997-01-0606 January 1997 Insp Repts 50-338/96-12 & 50-339/96-12 on 961102-1207. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20133C9491996-12-27027 December 1996 EN-96-098:order Prohibiting Involvement in NRC Licensed Activities Will Be Issued on or About 970102 to Unlicensed Individual Formerly Employed as Contract Millwright.State of VA Will Be Notified ML20149M5831996-12-0202 December 1996 Notice of Violation from Insp on 960922-1102.Violation Noted:Rce Had Not Been Completed for Several Pump 1-CH-P-1A Seal Failures Which Occurred Between 960211 & 0718 IR 05000338/19960101996-12-0202 December 1996 Insp Repts 50-338/96-10 & 50-339/96-10 on 960922-1102. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000338/19960111996-11-15015 November 1996 Insp Repts 50-338/96-11 & 50-339/96-11 on 961014-18.No Violations Noted.Major Areas Inspected:Plant Support PNO-II-96-081, on 961112,Unit 2 Experienced Turbine Generator Trip from 100% Power.Investigation Into Cause of Turbine Generator Trip Revealed Ground Fault on Main Generator Stator Phase a Windings.Addl Followup Will Be Performed1996-11-13013 November 1996 PNO-II-96-081:on 961112,Unit 2 Experienced Turbine Generator Trip from 100% Power.Investigation Into Cause of Turbine Generator Trip Revealed Ground Fault on Main Generator Stator Phase a Windings.Addl Followup Will Be Performed ML20134G9071996-10-21021 October 1996 Insp Repts 50-338/96-09 & 50-339/96-09 on 960811-0921. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20134G7971996-10-21021 October 1996 Notice of Violation from Insp on 960811-0921.Violation Noted:Procedure for Irradiated Fuel Damage While Refueling, 0-AP-30 Inadequate ML20128K0591996-09-30030 September 1996 Insp Repts 50-338/96-08 & 50-339/96-08 on 960812-16.No Violations Noted.Major Areas Inspected:Cr Simulator,Tsc,Osc, EOF, & Joint Info Ctr IR 05000338/19960071996-09-0909 September 1996 Insp Repts 50-338/96-07 & 50-339/96-07 on 960810.Violations Noted.Major Areas Inspected:Licensee Operations,Engineers, Maint & Plant Support ML20134C6401996-09-0909 September 1996 Notice of Violation from Insp on 960810.Violation Noted: on 940802,inadequate Maint Procedure Was Used to Control Maint Activities Affecting Quality IR 05000338/19940291994-12-29029 December 1994 Partially Withheld Insp Repts 50-338/94-29 & 50-339/94-29 on 941128-1202 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors IR 05000338/19930291994-01-12012 January 1994 Insp Repts 50-338/93-29 & 50-339/93-29 on Stated Date.No Violations Noted.Major Areas Inspected:Plant Status,Ler Followup,Safety Verification,Maintenance Observation, Surveillance Observation & Cold Weather Preparations ML20059L0511994-01-0404 January 1994 EN-94-001:on 940107,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $15,000 Will Be Issued.Action Based on Two Previous Similar Severity Level IV Violations Issued on 901207 & 920515 ML20059B2521993-12-14014 December 1993 Corrected NOV from Insp on 931017-1120,including Response Instruction ML20059B2751993-12-14014 December 1993 Notice of Violation from Insp on 931017-1120.Violation Noted:On 931029,periodic Test Procedure 2-PT-82H Was Not Implemented Correctly & While Performing Step 6.4.5,operator Incorrectly Placed Control Switch Breaker in pull-to-lock ML20059B2881993-12-14014 December 1993 Insp Repts 50-338/93-27 & 50-339/93-27 on 931017-1120. Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation & Surveillance Observation PNO-II-93-062, on 931115,Unit 2 Tripped from 95% Reactor Power.Caused by Three Main Feedwater Regulating Valves Closed.Unit Has Been Taken to cold-shutdown to Investigate Cause of SG Level Oscillations1993-11-16016 November 1993 PNO-II-93-062:on 931115,Unit 2 Tripped from 95% Reactor Power.Caused by Three Main Feedwater Regulating Valves Closed.Unit Has Been Taken to cold-shutdown to Investigate Cause of SG Level Oscillations IR 05000338/19930241993-11-15015 November 1993 Insp Repts 50-338/93-24 & 50-339/93-24 on 930919-1016.No Violations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Maintenance Observation, Surveillance Observation & LER Followup IR 05000338/19933011993-11-12012 November 1993 Exam Rept 50-338/93-301 on 931008-15.Exam Results:Eight ROs & Six SROs Passed Written & Operating Exams.Exam for Both Units IR 05000338/19930281993-10-29029 October 1993 Insp Repts 50-338/93-28 & 50-339/93-28 on 931014-20. Violations Noted.Major Areas Inspected:Circumstances Surrounding Unit 2 High Head Safety Injection Subsystem Not Meeting TS Min Flow Requirement on 931014 IR 05000338/19930261993-10-27027 October 1993 Insp Repts 50-338/93-26 & 50-339/93-26 on 930927-1001.No Violations or Deviations Noted.Major Areas Inspected: Licensee Radiation Protection Program,Involving Review of HP Activities Primarily Associated W/Unit 2 Refueling Outage IR 05000280/19933001993-10-20020 October 1993 Exam Repts 50-280/93-300 & 50-281/93-300 on 930920-24.Exam Results:Three SROs Passed Exam & One Out of Four ROs Failed Exam IR 05000338/19930211993-10-20020 October 1993 Insp Repts 50-338/93-21 & 50-339/93-21 on 930920-24.No Violations Noted.Major Areas Inspected:Organization of Chemistry Dept & Units Responsible for Handling & Shipping of Radioactive Matl & Plant Water Chemistry 1999-09-08
[Table view] |
Inspection Report - Surry - 1991022 |
---|
|
|
Text
. - - - - . . . . . - -. -. - - . . . - - - . - . . ~ _ . . . - - - - - . _ . - - . - . ~ . - - _
, ,
,
UNITED STATES
!
pEstug% ~ NUCLEAR REGULATORY COMMISSION i 4
[
n REGION 11 g ,j 101 MARIETTA STREET,N.W.
{
.
J ATLANTA, GEORGI A 30323 i
- *....
/
Report Nos.: 50-338/91-18 and 50-339/91-18
- 50-280/91-22 and 50-281/91-22 l Licensee
- Virginia Electric and Power Company
- Glen Allen, VA 23060
,
Docket Nos.: 50-338 and 50-339 License Nos.: NPF-4 and NPF-7 50-280 and 50-281 DPR-32 and DPR-37
! Facility Name: North Anna 1 and 2 j Surry 1 and 2 i Inspection Conducted:. July 31 and August 1-2, 1991
'
Inspector: fou% -, ed d E f/
Nick Economos, Rea:: tor Inspector Gate Signed Approved by: 8 3U .B ke, Chief Dhte Signed M er 1 and Processes Section gi eering Branch Division of Reactor Safety SUMMARY Scope:
l This special announced inspection was conducted for the purpose of evaluating the licensee's pipe wall thinning inspection and replacement program as l directed by corporate engineerin Also, the licensee's program for ensuring that longitudinal fitting welds are included in station inservice inspection (ISI) program was reviewe Results:
Through interviews of corporate engineering supervisors and senior engineering staff, along with reviews of engineering reports, procedures and drawings, the inspector has ascertained that the licensee has implemented a very comprehensive predictive and preventive maintenance program to monitor piping components subject to erosion-corrosion (E/C) wear. The program utilizes EPRI computer codes to locate and examine piping components subject to E/C wear. Components showing degradation are closely monitored, trended and evaluated by engineering using sufficient conservatism before approving them for continued servic Replacements are generally made from chrome-moly P11 or P22 materials which have demonstrated good resistance to erosion-corrosion attack in secondary water piping systems. These measures provide adequate assurance that a pipe rupture event such as the one experienced at the Surry Power Station in 1986 will not reoccu DR ADOCK0500g0
_ _ . _ __
.-_ __ . . - _ . . . . _ . _ .
REPORT DETAILS Persons Contacted Licensee Employees I. 8. Choate. Staff Engineer, Mechanical M. W. Henig, Project Engineer C. M. Hooper, Staff Engineer, Mechanical ,
- D. A. Somers, Licensing W, A. Thomas, Senior Staff Engineer, Mechanical
- E. W. Throckmorton, Supervisor, ISI/NDE Programs ,
- Attended exit interview Evaluation of Engineering Program (s) for the Control of Erosion / Corrosion Wear in Secondary Water Piping Systems (62700) j Following the feedwater pump suction piping rupture at Surry Power Station Unit 2 on December 9,1986, the licensee investigated the accident to determine the root cause for the failure and began to develop a program to obtain field data through nondestructive examinations, engineering evaluations, and prescribed corrective measures to preclude the recurrence of similar events. Engineering reports and procedures reviewed were as follows:
Erosion / Corrosion in Carbon Steel Piping, R&D Report #1880-0352, March 10, 1989 l
Secondary Piping and Component Inspection Program, STD-GN-0033, Rev. 1 ,
l
Engineering and Evaluation Procedure for UT Incpected Components, ME-022, Rev. 1
Recomendations to Upgrade Secondary Water Chanistry to Increase pH levels and Reduce Erosion / Corrosion Wear Rates at North Anna and Surry Power Stations I
A Review of the Virginia Power Erosion / Corrosion Inspection Program
The Surry Pipe Failure Analysis Sumary, April 1988
Engineering Outage Sumary Report, Secondary Piping and Component Inspection Program Surry Unit 2, 1991 Refueling Outage, IR-9734, June 18 1991 Through discussions with engineering management, engineering staff, and an in-depth review of the aforementioned engineering documents, the inspector ascertained that the licensee, as well as the nuclear industry, have
_ _ . _ - _ - - - - - - - .
_ - - - - . _ . _ - - _ - _ - - _ _ . - _ - - - - -
.
.
developed a relatively good understanding of the erosion / corrosion (E/C),
phenomenon in secondary water system carbon eteel piping where single and two phase liquid phase conditions exist. According to the literature referenced. E/C wear is caused by the electro-chemical (corrosive)
mechanisms of flowing wate Carbon steel piping under normal secondary system operating conditions corrodes to form a thin protective layer of iron oxide on the inside surfac If this protective layer is removed by the flow assisted corrosion process, the pipe's inside surface will start forming a new iron oxide layer. This cycle of iron oxide layer formation and subsequent removal, leads to a continuous pipe wall loss from the inside surfac The erosive wear mechanism of non-cavitating single liquid phase flow involves the dissolution of the oxide layer by the liquid flowing over its !
surface. The oxide formed on the steel has some finite solubility, or '
equilibrium concentration, in the high temperature water regime. If liquid water with a lower concentrate of dissolved oxygen comes into contact with the oxide surface, a concentration gradient is established
,
i and some of the oxide dissolves. Furthermore, if the water is moving, even more oxide will dissolve as a result of convective mass transpor This combination of ox,ide solubility and convective mass transfer is !
called the corrosion-dissolution wear mechanism. This mechanism will occur whenever a flowing liquid film contacts the oxide surfac {
The corrosion-dissolution mechanism is the reason that E/C occurs in two-phase and single liquid phase flows, but does not occur in single phase vapor (superheated steam) flows where no liquid is presen Theoretical equations have been written which express the relationship between E/C wear rates and the mass transfer coefficient. According to the literature, this coefficient has been shown experimentally to be an interdependent function of flow velocity, geometry, temperature and p Variables known to effect E/C wear in piping are: flow hydrodynamics--
velecity, geometry, and moisture (for two phase flow conditions); water chemistry--pH, oxygen level and temperature; piping material chemistry--
alloying elements, i.e., chromium, copper and molybdenum. Therefore, from a practical point of view, the only viable means for reducing E/C weer in most secondary water piping made of carbon steel material is by controlling water chemistry and piping materia Within these areas, the inspector ascertained that the licensee has utilized the Electric Power Research Institute (EPRI), computer code CHECMATE to investigate the effects of pH level on portions of the feedwater pump suction piping at Surry Unit I and determined that E/C wear rates can be reduced significantly by increasing the pH of the secondary water. This can be done by increasing the additions of the pH controlling agent or by changing the controlling agent to one which produces higher pH levels at the operating temperature. Subsequent to these findings and additional related investigations by engineering, the licensee implemented
.__-_ ._ _ . _ _ _ . _ _ _ _ _ _ . _ _ _ _ _ _ _ . _ _ _ - . _ .
'
i l
'
.'
.
i 3
!
i
!
I several changes at North Anna and Surry. These include changing the pH i controlling agent from hydrazine to morpholine; bypass of the powdered resin condensate polishers allowing for increased pH levels; replacement of feedwater heaters to help reduce copper in the systems; and installation
'
of transport monitors to trend corrosion transport levels to the secondary
- side of the steam generators. In addition, the inspector ascertained that i
- all feedwater heaters have been replaced with the exception of Surry Unit 2, which has four original feedwater heaters and two drain coolers. These
- are scheduled for replacement during the 1993 refueling outage.
] In reference to component replacement from low carbon steel to chrome-moly I
! material, the licensee, assisted by a contractor (Technicon) and the EP l computer codes CHEC, CHECMATE and CHEC-NDE, has implemented a very I
comprehensive program involving inspections, analysis and trending, i j Through research and field experience, the licensee has determined that i replacing existing low carbon steel material, which has zero chromium
>
content, with chrome molybdenum, P11/P22, materials, can reduce the j expected E/C wear rate by a factor of five.
! Accordingly, the licensee is proceeding with their inspection and component replacement program which is currently referred to as the
'
] Virginia Power Secondary Piping and Component Inspection Progra This
] program is administered under an engineering standard that is within the Virginia Power Nuclear Design Control Program. This document controls all
'
- aspects of the inspection program at both sites. The corporate engineering
- programs group is responsible for the overall administration of the
, program and corporate mechanical engineering is responsible for overall
{ program development, i.e., databases, criteria, system selection, et l
- Site mechanical engineering implements and tracks the inspection program j during the outages. It also evaluates inspection data, prepares procedures i
necessary to repair / replace degraded components and initiates procurement i of replacement piping materials. Site construction is responsible for j component repair / replacement while site NDE prepares components for
inspection and conducts data acquisition.
i Secondary water piping systems currently in the program include auxiliary steam, blowdown, condensate, extraction steam, feedwater, main steam,
, steam drains and water treatment. Approximately five-thousand components j have been identified for each of the four Virginia Power nuclear units.
- Each component within the systems defined as susceptible to E/C attack is
- assigned a station-unique identifie Isometric drawings have been i specifically prepared for all lines within these systems and each component
'
'
is identified. A separate database of these components exists for each unit. This database records not only the line, sketch, material, size and j schedule for each component but provides for the tracking of inspections
- and component replacement. This sorting of information allows engineering to easily identify areas of systems which may be entirely replaced due to i the projected piecemeal replacement of numerous individual components and
- to fine-tune the inspection program so as to eliminate areas which are
, consistently showing little wear.
,
, . . -. - - -,-
, _ . - - - - . - . - - .-- - .-. . - . . . . - - - _ - - - - - - . . _ . - . . -
.
. ,-
.
By data review, the inspector ascertained the total number of components replaced in terms of the total number of components inspected for each plant to be as follows:
Total Percent Components Replacement
,
North Anna Unit 1 4,994 14.6%
Unit 2 4,859 20.8%
Surry Unit 1 4,334 12.8%
Unit 2 4,184 12.7%
A review of piping inspection results and follow-up actions disclosed that during the 1990/91 outages, 51 of the 1,095 components inspected required replacement. One hundred seventy-nine components are considered potential next outage replacements, and an additional 302 components require inspection next outage. Finally, S63 components will require reinspection after two or more refueling outages as a result of the programmatic evaluatior, in 1990/91 Most of the piping replacements performed as a result of inspection at both sites utilized 2-1/4% chromium-1% molybdenum (chrome / moly) stee This practice was established during the 1988/89 refueling outages to reduce susceptibility to erosion / corrosion wear. Initial inspections of the gland steam system at North Anna indicated a more severe E/C problem than originally anticipated. All immediate replacements were with "in kind" materials due to cutage constraints. A gland steam system upgrade project is underway to replace much of the existing piping with either stainless steel or chrome / moly steel material In addition, the inspector ascertained that heavy E/C wear was observed on each of the four crossunder lines of each unit. This damage was generally confined to the region downstream of the turning vanes and the area around the expansion joints. The latter region has been the location of previous through-wall stream leaks during power operation. All heavily eroded areas were built-up to minimum wall thickness or greater by internal weld overla The records indicated that the condition of the crossover piping was generally very good. No weld repairs were required as a result of the programmatic inspections performed during the 1990/91 refueling outage By discussion with cogniztnt personnel, the inspector ascertained that in the interest of optimizing the inspection program and minimizing its impact on operation and maintenance costs, the licensee has undertaken a compre-hensive overview of the inspection program focusing on cost reductions for inspection and replacement of components without impacting plant safet _ _ _-
i
.
.
Within the areas inspected, violations or deviations were not identifie . Action Plan for Ensuring that Certain Longitudinal Fitting Welds are l Included in Station ISI Program (s) (73755)
On July 9,1991, Beaver Valley determined that inspections of longitudinal welds in the low head safety inspection fittings were not performed as required by the ASME Section XI testing program. The subject plant's drawings did not depict the longitudinal welds, and thus they were not included in the site ISI inspection plan. As a result, both trains of the low head safety injection system were considered to be inoperabl In response to this infonnation, on July 19, 1991, the licensee initiated an action plan to determine if the Beaver Valley finding is applicable to VEPC0's four units and at the same time prescribe a plan of corrective actions to be taken if it was determined that similar circumstances existe The subject memorandum / action plan was forwarded to Region II )
staff and to NRR. At the time of this inspection, the licensee was in the ;
preliminary stages of the action plan, attempting to sort out the applicable systems, code requirements, previously performed inspections, etc. The licensee provided the inspector with a listing of piping systems and potential lines which may contain fittings with longitudinal weld These included safety injection, primary coolant, recirculation spray, main steam, residual heat removal and chemical volume control, system The I licensee agreed to keep the inspector and the Region informed of developments as they occu Within the areas inspected, violations or deviations were not identifie Exit Interview l The inspection scope and results were summarized on August 2, 1991, with those persons indicated in paragraph 1. The inspector described the areas inspected and discussed in detail the inspection finding Dissenting comments were not received from the license l l
J J