BOY 11 1S89 Mr. Oliver D. Kingsley, Jr.

Senior Vice President, Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

Dear Mr.'Kingsley:

SUBJECT:

INSPECTION REPORT NOS. 50-259/89-38, 50-260/89-38, AND 50-296/89"38 Thank you for your response of November 1,

1989, to our Notice of Violation, issued on October 2, 1989, concerning activities conducted at your Browns Ferry facility.

We have evaluated your response and found that it. meets. the requirements of

CFR 2.201.

We will examine the implementation of.your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely, lJQP

I ~

Bruce A. Wilson, Assistant Director for Inspection Programs TVA Projects Division Office of Nuclear Reactor Regulation cc:

(See page 2)

891122 C< pgppp259

),

pasS 891>>1 ADO PDC

~O/

cc:

F.

L. Moreadith, Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.

O.

Box 2000 Decatur, AL 35602 G. Campbell, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 TVA Representative Rockvi lie Office 11921 Rockvi1 le Pike Suite 402 Rockville, MD 20852 General Counsel Tennessee Valley Authority 400 West Summit Hill Drive ET 11B 33H Knoxvi 1 le, TN 37902 Claude Earl Fox, M.D.

State Health Offi.cer State Department 'of Public Health State Office Building Montgomery, AL 36130 Manager, Nuclear Licensing and Regulatory Affairs Tennessee Valley Authority 5N 157B Lookout Place Chattanooga, TN 37402-2801 State 'of Alabama bcc:

P. Carier, Site'icensing Manager Nuclear Engineering Tennessee Valley Authority 400 West Summit Hill Drive WT 12A 12A Knoxville, TN 37902 Dr.

M. 0.. Medford Vice President and Nuclear Technical Director Tennessee Valley Author ity 6N 38A Lookout Place Chattanooga, TN 37402-2801 Chairman, Limestone County Commission P. 0.

Box 188 Athens, AL 35611 Dr. Henry Myers,-Science Advisor Committee on Interior and Insular Affairs U. S.

House of Representatives Washington, D.

C.

20515 0. J. 2eringue, Site Director Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 D.

M. Crutchfield, NRR B.

D. Liaw, NRR S.

C. Black, NRR R.

C. Pierson, NRR G.

E. Gears, NRR D. Moran, NRR W.

S. Little, NRR/RII A. H. Johnson, NRR/RII AD R.

Long, NRR/RII J.

Rutberg, OGC M. S. Callahan, GPA/CA NRC Document Control Desk NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 12, Box 637 Athens, AL 35611 RII:NRR RI Wi tl o nson.vyg 11/g /89 11/f) /89

I>>

I,i C