IR 05000259/1989027

From kanterella
Jump to navigation Jump to search
Advises That Corrective Actions for Conditions Described in LER 89-09 Adequate,Per Insp Repts 50-259/89-27,50-260/89-27 & 50-296/89-27
ML18033B551
Person / Time
Site: Browns Ferry  
Issue date: 11/02/1990
From: Wilson B
NRC Office of Inspection & Enforcement (IE Region II)
To: Kingsley O
Tennessee Valley Authority
References
NUDOCS 9011160183
Download: ML18033B551 (4)


Text

'e M0V o g )II~

Docket Nos. 50-259, 50-260, 50-296 License Nos.

DPR-33, DPR-52, DPR-68 Mr. Oliver D. Kingsley, Jr.

Senior Vice President, Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

Dear Mr. Kingsley:

SUBJECT:

INSPECTION REPORT NOS. 50-259/89-27, 50-260/89-27, AND 50-296/89-27 Our letter of November 16, 1990, stated that we were requesting that the NRR technical staff review your denial of Example 2 of Violation B.

This example was for failure to submit a Licensee Event Report (LER) within 30 days after discovery of the event concerning the single failure of fire pump lockout relays.

The staff concluded that there was insufficient basis available to support TVA's engineering judgement that the postulated relay failure scenario would only trip one diesel generator.

The ability of some systems to fulfilltheir safety functions was indeterminate during certain plant accident conditions and should have been reported in accordance with 10 CFR 50.73.

A voluntary LER (89-09)

was submitted after the

day requirement and committed TVA to install an additional lockout relay prior to restart of Unit 2.

The staff finds that the corrective action for the conditions described in LER 89-09 is adequate.

Since the plant modifications are now complete, no further response is required.

We appreciate your cooperation in this matter.

Sincerely, cc:

(See page 2)

TVA Projects

..w V~ v~

90iiibOi83 90ii02 PDR ADOCN, 05000259 G

PNU

HOY Os fgg

Tennessee Valley Authority CC:

M. Runyon, Chairman Tennessee Valley Authority ET 12A 7A 400 West Summit Hill Drive Knoxville, TN 37902 Director Tennessee Valley Authority ET 12A llA 400 West Summit Hill Drive Knoxville, TN 37902 J.

B. Waters, Director Tennessee Valley Authority ET 12A 9A 400 West Summit Hill Drive Knoxville, TN 37902 W. F. Willis Chief Operating Officer ET 12B 16B 400 West Summit Hill Drive Knoxville, TN 37902 D. Nunn, Vice President

.Nuclear Engineering Tennessee Valley Authority 400 West Summit Hill Drive WT 12A 12A Knoxville, TN 37902 Dr.

M. 0. Medford Vice President and Nuclear Technical Director Tennessee Valley Authority 6N 38A Lookout Place Chattanooga, TN 37402-2801 Chairman, Limestone County Commission P. 0.

Box 188 Athens, AL 35611 Dr. Henry Myers, Science Advisor Committee on Interior and Insular Affairs U. S.

House of Representatives Washington, D. C.

20515 0. J. Zeringue, Site Director Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 E.

G. Wallace, Manager Nuclear Licensing and Regulatory Affairs Tennessee Valley Authority 5N 157B Lookout Place Chattanooga, TN 37402-2801 P. Carier, Site Licensing Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 L.

W. Myers; Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur,'L 35602 TVA Representative Rockville Office 11921 Rockvil le Pike Suite 402 Rockville, MD 20852 General Counsel Tennessee Valley Authority 400 West Summit Hill Drive ET llB 33H Knoxville, TN 37902 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, AL 36130 State of Alabama bcc:

(See page 3)

NOV 02 39'cc:

S.

C. Black, NRR P. J. Kellogg, TVAP/RII J. Rutberg, OGC M. S. Callahan, GPA/CA R.

H. Bernhard, TYAP/RII G.

C. Lainas, NRR F. J.

Hebdon, NRR T.

M. Ross, NRR NRC Document Control Desk DRP Section Chief NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 12, Box 637 Athens, AL 35611 TV :R I CP tterson:vyg 10/P/90 TVA:

PKe ogg 10$ ( /90