IR 05000259/1989036

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-259/89-36, 50-260/89-36 & 50-296/89-36
ML18033B064
Person / Time
Site: Browns Ferry  
Issue date: 11/17/1989
From: Wilson B
Office of Nuclear Reactor Regulation
To: Kingsley O
Tennessee Valley Authority
References
NUDOCS 8912080077
Download: ML18033B064 (4)


Text

ACCE1ZRATZD DISCI'RIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8912080077 DOC.DATE: 89/ll/17 NOTARIZED: NO DOCKET g

FACZL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 05000259 50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILIATION WILSON,B.A.

Assistant Director for Inspection Programs WILSON,B.A.

Region 2, Ofc of the Director RECIP.NAME RECIPIENT AFFILIATION KINGSLEY,O.D.

Tennessee Valley Authority SUBJECT:

Ack receipt of 891106 ltr informing NRC of steps taken to correct violations noted in Insp Repts 50-259/89-36.

DISTRIBUTION CODE:

ZEOID COPIES RECEIVED:LTR i ENCL Q SZSE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:1 Copy each to: B.Wilson,D.M,Crutchfield,B.D.Liaw,S.Black R.Pierson, 1 Copy each to: S.Black,D.M.Crutchfield,B.D.Liaw,

. R.Pierson,B.Wilson 1 Copy each to:

S. Black,D.M.Crutchfield,B.D.Liaw, R.Pierson,B.Wilson 05000259 j O5OOO26O A 05000296~

RECIPIENT ID CODE/NAME PD ERNAL: ACRS AEOD/DEIIB DEDRO NRR/DET/DIR 8H3 NRR/DOEA DIR ll NRR/DREP/PRPB11 NRR/DST/DIR 8E2 NUDOCS-ABSTRACT OGC/HDS2 RES MORISSEAU,D EXTERNAL: LPDR NSIC COPIES LTTR ENCL

1

1

2

1

-1 RECIPIENT ID CODE/NAME GEARSiG AEOD AEOD/TPAD NRR SHANKMAN,S NRR/DLPQ/LPEB10 NRR/DREP/PEPB9D NRR/DRIS/DIR NRR/PMAS/ILRB12 OE L EBE NzJ FILE R

NRC PDR COPIES LTTR ENCL NOTES:

h t

CO'OTAL NUMBER OF COPIES REQUIRED:

LTTR

ENCL

WOVE p )~

Mr. Oliver D. Kingsley, Jr.

Senior Vice President, Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street

. Chattanooga, TN 37402-2801

Dear Mr. Kingsley:

SUBJECT:

INSPECTION REPORT NOS. 50-259/89-36, 50-260/89-36, AND 50-296/89-36 Thank you for your response of November 6, 1989, to our Unresolved Item, issued on September 21, 1989, concerning activities conducted at your Browns Ferry facility.

We are evaluating your response and will examine the implementation of your corrective act'ions during future inspections.

We appreciate your cooperation in this matter.

Sincerely,

'J g~i4 $y 4+>~)

Bruce A. Wilson, Assi stant Director for Inspection Programs TVA Projects Division Office of Nuclear Reactor Regulation cc:

(See page 2)

8912080077 891117 PDR ADOCK 05000259

PNU

Nr. Oliver D. Kiegsley, Jr.

cc:

F.

L. Moreadith, Vice President Nuclear Engineering Tennessee Valley Authority 400 West Summit Hill Drive WT 12A 12A Knoxville, TN 37902 Dr.

M. 0. Medford Vice President and Nuclear Technical Director Tennessee Valley Authority 6N 38A Lookout Place Chattanooga, TN 37402-2801 Chairman, Limestone County Commission P. 0.

Box 188 Athens, AL 35611 Dr. Henry Myers, Science Advisor Committee on Interior" and Insular Affairs U.

S.

House of Representatives Washington, D.

CD 20515 0. J. Zeringue, Site Director Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 Manager, Nuclear Licensing and Regulatory Affairs Tennessee Valley Authority 5N 157B Lookout Place Chattanooga, TN 37402-2801 bcc:

P. Carier, Site Licensing Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 G: Campbell, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000 Decatur, AL 35602 TVA Representative Rockville Office 11921 Rockvil le Pike Suite 402 Rockvi lie, MD 20852 General Counsel Tennessee Val 1 ey Authority 400 West Summit Hill Drive ET 11B 33H Knoxville, TN 37902 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, AL 36130 State of Alabama D.

M. Crutchfield, NRR B.

D. Liaw, NRR S.

C. Black, NRR R.

C. Pierson, NRR G. E.'Gears, NRR D. Moran, NRR W. S. Little, NRR/RII A. H. Johnson, NRR/RII A.

R.

Long, NRR/RII J.

Rutberg, OGC M. S. Callahan, GPA/CA NRC Document Control Desk NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 12, Box 637 Athens, AL 35611 RI I/NRR AJohHson:vyg 11//0/89 RII/PP WLi le 11/ ~