05000220/LER-1983-025, Corrected LER 83-025/04L-0:while Reviewing Environ Radiation Fish Analysis Sample Data,Determined That Lower Limit of Detection Sensitivity Not Met for Several Radionuclides During Analysis of May Fish Samples

From kanterella
(Redirected from 05000220/LER-1983-025)
Jump to navigation Jump to search
Corrected LER 83-025/04L-0:while Reviewing Environ Radiation Fish Analysis Sample Data,Determined That Lower Limit of Detection Sensitivity Not Met for Several Radionuclides During Analysis of May Fish Samples
ML20117M174
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 09/09/1983
From: Kesel D, Mangan C
NIAGARA MOHAWK POWER CORP.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
LER-83-025-04L, LER-83-25-4L, NMP-7109, NUDOCS 8505160559
Download: ML20117M174 (2)


LER-2083-025, Corrected LER 83-025/04L-0:while Reviewing Environ Radiation Fish Analysis Sample Data,Determined That Lower Limit of Detection Sensitivity Not Met for Several Radionuclides During Analysis of May Fish Samples
Event date:
Report date:
2202083025R00 - NRC Website

text

'"

O ucENSEE EV'ENT REPORT dONTROL BLOCK: l l l l l l (PLE ASE PRINT OR TYPE ALL REQUIRED INFOIMATIONI Si CAT 68l@

l

%1 l 9N l Y l N l M l P l 1 l@150 l 0 l - 10 l 0 l 0 l 0 l 0 LICENSE LICENSEE CoOE le LICENSE NUMBER 25 l- l0 TvPE 10 JOl@26hl ll ll ll 11@

CON'T R 1% LL_j@l0 l 510101012121068 l@l01510 00 St DOCKET NUMSER 89 lo 18 h l@l nl ol EVENT DATE 74 75 nl ol Al 1l@

FiEPORT DATE 80 EVENT DESCRIPTION ANO PROSASLE CONSEQUENCES h

""r.na 'l While reviewing , Environmental Radiation fish analysis sample data, it was determined l r.a u l that the lover limit of detection sensitivity (LLD) was not met for several radio- l 0 4 lnuclides during analysis of May fish samples (Environmental Tech. Spec. Table 3.2-1 l o s l applies). This has no Environmental concerns because this is a matter of specific l oo l testing sensitivity and results do fall within applicable Regulatory Guide 4.8 Speci- l o y lfications. LERs 81-10, 81-51, 82-07, 82-12 and 83-03 reported similar occurrences. l l

e I 80 7 89 "'

'$$" *#"'e' C0O seCEE COMPONENT CODE SUB OOE $ E E

P S I z I z l@ [X_j@ lz_J@ I z l z l z i z i z I z l@ l_ZJ@

9 10 11 12 33 to 19 LZ_l 20 REVISION

,,,, JEQUE NTI AL OCCURRENCE REPORT REPORT NO. COOE TvPE NO, LE R EVENT vE AR O ,ajg/RO  ; I 81 31 [--J 1012lfl y 10 l h l 28 29 LL1 30

- L- .]

31

[0 J2_

]

25 22 23 24 26 27

'A HOUR $ 22 S. SUP L R MAN FACTURER

$8 IT D Wg L NT FOR Wg K MET Qd@ d@ (,,zj@

l0l0l0lul 3J 40 4l Jg 42 43 l44X [9 l9 l947l@

33 34 3b 36 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i O lThe station Tech. Specs, specify radiological fish analysis LLD to be 80 pei/kg dry l i lveight. When laboratory test data is converted from vet weight units to dry weight I l

g l units, higher LLD values resulted. Radiological Effluent Technical Specifications i 3 l(RETS) are in the process of being submitted to update this parameter to the current l l Regulatory Guide Values; recurrence of this problem is expected until the RETS proposah a0 7 s 91s approved.

STA  % POWE R OTHER STATUS is O Rv OtSCOVERY OESCRIPTION

[Bjgl Supervisory Reviev l i s W @ 'l0l0l0l@ln 12 NA 44 l

43 46 s0 ACnviTY CO0 TENT RELEASED OF RELEASE AMOUNT OF ACTIVITY NA I LOCAflON^ %# RELEASE l

$

  • l-LZ1@LzJ@l PERSONNEL ExPOsu tS NUM.ER Tv,E OfiCRI, TION @

HA Q l 0 l 0 l 0 l@[z j@l _

a l

,e,4 so .~d' .Nm'd.c s  ;

NomER oEsen,P,m~@ '

n E

lololOl@l k "

]

OF O Q W @ lgoha,ctvoraCitity(ii) . 8505160559 830909 PDR ADOCK 05000220

'A

,o l

, e , iO eUnticity S PDR NHC LM ONLY ,

OEsCRienON Q$)

2 O i UEo@l N NA l lllllllllllll} 30 ;

I 8 9 to 68 69 D.T. Kesel (315)349-2611 o NAME OF PREPARER PHONE: $

r DESIGNATED NAL UMOHAWK cerunea ny -

y,_ , g g NIAGARA MOHAWK POWER CORPORATION /300 ERIE BOULEVARD WEST, SYRACUSE. N Y.13202/ TELEPHONE (315) 474-1511 September 23, 1983 Or. Titomas E. Marley Regional Administrator United States Nuclear Regulatory Corrmi.ssion Region I 631 Park Avenue King of Panssia, Pennsylvattia 19406 RE: Docket No. 50-220 LER 83-25 Ocar Dr. Murtey, in accordance wi.th Nine Mlle Point Nuc1 car Station Unit M1 Technical Specificattons, we hereby subntt the following Licensee Event Report:

83-25 in accordance with Section 4.6.2a "Non-routine Environmental Operating Reparts" witere a report shall be submitted in the event that (b) a report Icvet or specification is reached as specified in Section 3, " Environmental Surveit-Lance".

Tlvis report uns completed in the format designated in NUREG-0161, dated July 1977 Sincerely, Ch % dW a.4 C.V,t.htngd}h Vice Ptesident Nuclear Engineering & Licensing TEL/jm Attacitments (3 copics) cc: DLiectet, Office of ISE (30 cepic5) p.~a? - p::, c , -

m n; <. ,;,..' 1)

O

\9'\ l

/

< #