05000220/LER-2016-001, Regarding Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors

From kanterella
(Redirected from 05000220/LER-2016-001)
Jump to navigation Jump to search
Regarding Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors
ML16202A148
Person / Time
Site: Nine Mile Point 
Issue date: 07/12/2016
From: Kreider R
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP1L 3093 LER 16-001-00
Download: ML16202A148 (7)


LER-2016-001, Regarding Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(i)
2202016001R00 - NRC Website

text

,Alfi

'/

~ Exelon Generation NMP1L3093 July 12, 2016 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Nine Mile Point Nuclear Station, Unit 1 Renewed Facility Operating License No. DPR-63 Docket No. 50-220 10 CFR 50.73

Subject:

NMP1 Licensee Event Report 2016-001, Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors In accordance with the reporting requirements contained in 1 O CFR 50.73(a)(2)(v)(C), please find enclosed NMP1 Licensee Event Report (LER) 2016-001, Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors.

There are no regulatory commitments contained in this letter.

Should you have any questions regarding the information in this submittal, please contact Dennis Moore, Site Regulatory Assurance Manager, at (315) 349-5219.

Respectfully,

~~~.

Robert E. Kreider Jr.

Plant Manager, Nine Mile Point Nuclear Station Exelon Generation Company, LLC REK/KJK

Enclosure:

NMP1 Licensee Event Report 2016-001, Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors cc:

NRC Regional Administrator, Region I NRC Resident Inspector NRC Project Manager

Enclosure NMP1 Licensee Event Report 2016-001, Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors Nine Mile Point Nuclear Station, Unit 1 Renewed Facility Operating License No. DPR-63

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 10/31/2018 (11-2015)

, the NRG may not conduct or sponsor, and a person is not required to respond to, the information collection.

3. PAGE Nine Mile Point Unit 1 05000220 1 OF 5
4. TITLE Secondary Containment Inoperable Due to Simultaneous Opening of Airlock Doors
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED I

SEQUENTIAL I REV FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR NUMBER NO.

MONTH DAY YEAR N/A N/A FACILITY NAME DOCKET NUMBER 06 01 2016 2016 - 001

- 00 07 12 2016 N/A N/A
9. OPERATING MODE
11. THIS REPORT IS SUBMITIED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: {Check all that apply)

D 20.2201 (b)

D 20.22oa(a)(a)(il D 50.73(a)(2)(ii)(A)

D 50.73(a)(2)(viii)(A) 1 D 20.2201 (dl D 20.22oa(a)(a)(iil D 50.73(a)(2)(ii)(B)

D 50.73(a)(2)(viii)(B)

D 20.22oa(a)(1 i D 20.22oa(a)(4)

D so.1a(a)(2)(iiil D 50.73(a)(2)(ix)(A)

D 20.22oa(a)(2)(il D 50.36(c)(1 )(i)(A)

D 50.73(a)(2)(iv)(A)

D 50.73(a)(2)(x) 1 O. POWER LEVEL D 20.22oa(a)(2)(iil D 50.36(c)(1)(ii)(A)

D 50.73(a)(2)(v)(A)

D 1a.11(a)(4l D 20.22oa(a)(2)(iiil D so.as(c)(2)

D 50.73(a)(2)(v)(B)

D 1a.11 (a)(s)

D 20.2203(a)(2)(iv)

D so.4s(a)(3l(iil [8] 50.73(a)(2)(v)(C)

D 1a.11(a)(1>

100%

D 20.2203(a)(2)(v)

D 50.73(a)(2)(i)(A)

D 50.73(a)(2)(v)(D)

D 1a.11(a)(2)(i)

D 20.2203(a)(2)(vi)

D 50.73(a)(2)(i)(B)

D 50.73(a)(2)(vii)

D 1a.11(a)(2)(n>

D 50.73(a)(2)(i)(C)

D OTHER Ii*

r*.*

l Specify in Abstract below or in D. DATES AND APPROXIMATE TIMES OF MAJOR OCCURRENCES AND OPERATOR ACTIONS:

The dates, times, and major occurrences and operator actions for this event are as follows. All dates are 2016.

June 1 1046 Individual 1 had entered the airlock via door D-53 (inner door) and was in the process of exiting the airlock via door D-52 (outer door).

1046 Without verifying on the monitors that other personnel were either in the airlock or attempting to enter the airlock through the opposing door D-52, Individual 2 opened door D-53 while Individual 1 was opening door D-52.

1046 Upon the realization that both doors had been breached simultaneously, the doors were immediately (less than 5 seconds) closed re-establishing containment integrity.

During the time both doors are open, NMP1 Limiting Condition of Operation 3.4.3 is not met. *

E. METHOD OF DISCOVERY

This event was self-identified by station personnel traversing the Reactor Building airlock doors.

F. SAFETY SYSTEM RESPONSES:

The duration of the event was 5 seconds, or less. Review of the Reactor Building differential pressure as recorded by the plant process computer for the time period of the event indicated that the actual differential pressure remained negative and was unaffected by the brief simultaneous opening of the airlock doors. Operators entered the applicable TS action statement then exited it soon afterwards. The event concluded when the airlock door was shut.

II. CAUSE OF EVENT

The cause of this event is personal accountability. With clear understanding of the expectations for using the airlock doors in conjunction with all mechanical barriers (lights, buzzers, monitors) functioning properly, the individual failed to use human performance tools to verify the airlock was not already being used by other individuals.

III. ANALYSIS OF THE EVENT

YEAR 2016

3. LER NUMBER SEQUENTIAL NUMBER 001 Simultaneous opening of both reactor building airlock doors is reportable under 1 O CFR 50.72(b)(3)(v)(C) and 1 O CFR 50~73(a)(2)(v)(C) as any event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to control the release of radioactive material.

Secondary containment structural integrity, the ability to automatically isolate the non-safety related Reactor Building ventilation system, and the Reactor Building Emergency Ventilation System availability were not impacted by the event. It is concluded that the safety significance of this event is low and the event did not pose a threat to the health and safety of the public or plant personnel.

The analysis of the event determined the safety function was not prevented from being fulfilled, the occurrence is not considered a safety system functional failure. This event does not affect the NRC Regulatory Oversight Process Indicators.

IV. CORRECTIVE ACTIONS

A. ACTION TAKEN TO RETURN AFFECTED SYSTEMS TO PRE-EVENT NORMAL.

STATUS:

Airlock doors were closed and secondary containment was restored to Operable status.

B. ACTION TAKEN OR PLANNED TO PREVENT RECURRENCE:

In accordance with station policies and procedures, Performance Management was applied to the individual who failed to use their human performance**tools resulting in both airlock doors being opened simultaneously.

V. ADDITIONAL INFORMATION

A. FAILED COMPONENTS:

There were no failed components that contributed to this event.

B. PREVIOUS LERs ON SIMILAR EVENTS:

NMP1 LER 2014-004, August 13, 2014.

NMP1 LER 2014-005, October 16, 2014.

NMP1 LER 2014-006, October 20, 2014.

NMP1 LER 2015-001, February 11, 2015.

NMP1 LER 2015-002, March 3, 2015.

2016 -

001 NMP1 LER 2015-003, August 5, 2015.

For the LERs listed above, the secondary containment of the Nine Mile Point Unit 1 (NMP1) Reactor Building was breached when workers opened both inner and outer airlock doors simultaneously while passing through. The integrity of the airlock was re-established within 5 seconds, or less, when one of the doors was closed and latched.

Secondary Containment differential pressure was unaffected by these events.

C. THE ENERGY INDUSTRY IDENTIFICATION SYSTEM (EIIS) COMPONENT FUNCTION IDENTIFIER AND SYSTEM NAME OF EACH COMPONENT OR SYSTEM REFERRED TO INTHISLER:

COMPONENT Reactor Building (BWR)

Reactor Building Ventilation System Airlock Door D. SPECIAL COMMENTS:

None IEEE 803 FUNCTION IDENTIFIER N/A PDIC DR IEEE 805 SYSTEM IDENTIFICATION NG VA NG 00