IR 07200058/2008003

From kanterella
Revision as of 15:53, 27 August 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
IR 07200058-08-003, on 12/31/2008, Monticello Nuclear Generating Plant, Errata Inspection
ML090340174
Person / Time
Site: Monticello  Xcel Energy icon.png
Issue date: 02/02/2009
From: Lipa C A
NRC/RGN-III/DNMS/DB
To: O'Connor T J
Northern States Power Co
References
IR-08-003
Download: ML090340174 (3)


Text

February 2, 2009

Mr. Timothy Site Vice President Monticello Nuclear Generating Plant Northern States Power Company, Minnesota 2807 West County Road 75 Monticello, MN 55362-9637

SUBJECT: ERRATA TO MONTICELLO NUCLEAR GENERATING PLANT - NRC INSPECTION REPORT 072-00058/2008-003(DNMS)

Dear Mr. O'Connor:

On December 31, 2008, U.S. Nuclear Regulatory Commission (NRC) issued an inspection report (see ADAMS ML083660296) pertaining to the preoperational testing of an Independent Spent Fuel Storage Installation (ISFSI) at the Monticello Nuclear Generating Plant. After discussions with your staff and further review of the report we determined that information in Paragraphs 5 and 14 in the Structural Modifications and Associated Design Documentation section should be revised as described below.

The following information in Paragraphs 5 and 14:

"The licensee was required by Title 10 Code of Federal Regulations (CFR) 72.92(a) to identify the natural phenomena that could occur in the region and to assess their potential effects on the safe operation of the ISFSI or Monitored Retrievable Storage Installation (MRS). The important natural phenomena that affect the ISFSI or MRS design must be identified. According to the Monticello Updated Safety Analysis Report, Section 2.3.5, tornadoes were a natural phenomena that could occur at the Monticello site," and

"Title 10 CFR Part 72.92(a), "Design Bases External Natural Events," requires, in part, that natural phenomena that may exist or that can occur in the region of a proposed site must be identified and assessed according to their potential on the safe operation of the ISFSI." should both be revised to:

"The licensee was required by Title 10 Code of Federal Regulations (CFR) 72.212(b)(3) to review the safety analysis report and the related safety evaluation report, prior to use of the general license, to determine whether or not the reactor site parameters, including analyses of earthquake intensity and tornado missiles, are enveloped by the cask design bases considered in these reports. The results of this review must be documented in the evaluation made in paragraph (b)(2) of this section." In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). The NRC's document system is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. We apologize for any inconvenience to you and your staff. If you have questions please contact Sarah Bakhsh of my staff at (630) 829-9816.

Sincerely,/RA/ Christine A. Lipa, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket No.72-058; 50-263 License No. DPR-22 cc: D. Koehl, Chief Nuclear Officer Manager, Nuclear Safety Assessment P. Glass, Assistant General Counsel Nuclear Asset Manager, Xcel Energy, Inc. J. Stine, State Liaison Officer, Minnesota Department of Health R. Nelson, President Minnesota Environmental Control Citizens Association Commissioner, Minnesota Pollution Control Agency R. Hiivala, Auditor/Treasurer, Wright County Government Center Commissioner, Minnesota Department of Commerce Manager - Environmental Protection Division Minnesota Attorney General's Office DISTRIBUTION:

See next page

  • see previous concurrence DOCUMENT NAME: G:\SEC\Work in progress\ERRATA TO DRY RUN IR (SB).doc Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII-DNMS C RIII-DRP C RIII-EICS C RIIIDNMS C NAME SBakhsh:jc * JENeurauter T JB for * KGO'Brien CALipa DATE 01/ 23/09 01/23/09 01/ 26/09 02/02/09 OFFICIAL RECORD COPY Letter to Timothy O'Connor from Christine A. Lipa dated February 2, 2009 DISTRIBUTION
Mark Satorius Steven Reynolds Cynthia Pederson Kenneth O'Brien Allan Barker Jared Heck Kenneth Riemer Christopher Thomas Luke Haeg Silvia Brouillard David Hills Carole Ariano Paul Pelke Patricia Buckley Tammy Tomczak Nick Shah Jeremy Tapp William Snell Matthew Learn Lionel Rodriguez