Letter Sequence Response to RAI |
---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request
- Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
|
MONTHYEARML12285A2652012-10-0101 October 2012 Attachment 4 - MHI Document L5-04GA564 - Tube Wear of Unit-3 RSG, Technical Evaluation Report Project stage: Request ML12285A2672012-10-0101 October 2012 Attachment 4: SG Tube Wear Analysis for Unit-2/3 Project stage: Request ML12285A2662012-10-0101 October 2012 Attachment 4: Appendix-2 Attachment-1, Tube-to-TSP Wear Depth Diagram for Unit-2/3 Project stage: Request ML12285A2642012-10-0101 October 2012 Attachment 3 - Areva Document 51-9180143-001 - SONGS Unit 3 February 2012 Leaker Outage Steam Generator Condition Monitoring Report Project stage: Request ML12285A2682012-10-0202 October 2012 Attachment 6 - Appendix B: SONGS U2C17 - Steam Generator Operational Assessment for Tube-to-Tube Wear Project stage: Request ML12285A2692012-10-0202 October 2012 Attachment 6: Appendix a: Estimates of FEI-Induced Ttw Rates Project stage: Request ML12285A2632012-10-0303 October 2012 Confirmatory Action Letter - Actions to Address Steam Generator Tube Degradation Project stage: Request ML12338A1102012-11-30030 November 2012 Email, Request for Additional Information Southern California Edison'S Response to Nrc'S Confirmatory Action Letter (CAL) 4-12-001 Dated March 27, 2012 Project stage: RAI ML12341A1122012-12-0707 December 2012 Notice of Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 Project stage: Meeting ML12347A0662012-12-0707 December 2012 Revised Notice of 12/18/12 Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 Project stage: Meeting ML12345A4272012-12-10010 December 2012 Revised Email, Request for Additional Information Review of Southern California Edison'S Response to Nrc'S 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report Project stage: RAI ML12353A0972012-12-13013 December 2012 LTR-12-0795 - E-mail Don Leichtling Concerns Media Alert - Nuclear News - NRR Forthcoming Meeting with Southern California Edison Company Project stage: Meeting ML12352A3852012-12-18018 December 2012 Licensee Slides for 12/18/12 Public Meeting Project stage: Meeting ML12352A4112012-12-18018 December 2012 NRC Slides for 12/18/12 Meeting with Southern California Edison Project stage: Meeting ML12356A1982012-12-20020 December 2012 Email, Request for Additional Information, Round 3, Review of Southern California Edison'S Response to Nrc'S 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report Project stage: RAI ML13009A3492013-01-0808 January 2013 Response to Request for Additional Information Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13014A2512013-01-0909 January 2013 Response to Request for Additional Information (RAI 30) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13014A2492013-01-0909 January 2013 Response to Request for Additional Information (RAI 15) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13015A0042013-01-10010 January 2013 Response to Request for Additional Information (RAI 16), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A0882013-01-16016 January 2013 Response to Request for Additional Information (RAI 19) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A4132013-01-17017 January 2013 Response to Request for Additional Information (RAIs 10 and 17) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13022A4812013-01-18018 January 2013 Response to Request for Additional Information (RAI 13), Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13022A4082013-01-18018 January 2013 Response to Request for Additional Information (RAI 12), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A4112013-01-21021 January 2013 Response to Request for Additional Information (RAI 11) Regarding Confirmatory Action Letter Response (TAC Me 9727) Project stage: Response to RAI ML13022A4052013-01-21021 January 2013 Response to Request for Additional Information (RAI 28), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13028A0982013-01-24024 January 2013 Response to Request for Additional Information (RAI 18) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13028A4752013-01-25025 January 2013 Response to Request for Additional Information (RAI 27) Regarding Confirmatory Action Letter Project stage: Response to RAI ML13028A4742013-01-25025 January 2013 Response to Request for Additional Information (RAIs 5, 7, and 9) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13032A0092013-01-29029 January 2013 Response to Request for Additional Information (RAI 14) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13037A1122013-01-31031 January 2013 Response to Request for Additional Information (RAI 29) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13053A3672013-02-0101 February 2013 E-mail, Draft Request for Additional Information Southern California Edison'S Response to Nrc'S Confirmatory Action Letter Project stage: Draft RAI ML13038A0102013-02-0404 February 2013 Response to Request for Additional Information (RAI 8) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13038A0092013-02-0404 February 2013 Response to Request for Additional Information (RAI 6) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13039A2782013-02-0606 February 2013 Response to Request for Additional Information (RAIs 20, 21, 22, 23, 24, 26 & 31), Confirmatory Action Letter Project stage: Response to RAI ML13039A3172013-02-0707 February 2013 Response to Request for Additional Information (RAI 25) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13050A1892013-02-14014 February 2013 Supplemental Document Submittal Regarding Confirmatory Action Letter Response, Concerning Steam Generator Tubes Project stage: Supplement ML13051A1972013-02-15015 February 2013 Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Cover Through Page 227 of 415 Project stage: Other ML13051A1992013-02-15015 February 2013 Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Page 228 of 415 Through End Project stage: Other ML13046A1232013-02-15015 February 2013 2/27/2013 Notice of Forthcoming Meeting with Southern California Edison Company to Discuss Confirmation Action Letter Project stage: Meeting ML13051A1932013-02-18018 February 2013 Enclosure 5, L5-04GA585, Rev. 2, Analytical Evaluations for Operational Assessment Project stage: Other ML13051A1922013-02-18018 February 2013 Enclosure 4, L5-04GA567, Rev. 6, Evaluation of Stability Ratio for Return to Service Project stage: Other ML13051A1902013-02-18018 February 2013 Supplemental Document Submittal Regarding Confirmatory Action Letter Response to Address Steam Generator Tube Degradation Project stage: Supplement ML13056A0922013-02-20020 February 2013 Email, Draft Request for Additional Information Nos. 38-52, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter Project stage: Draft RAI ML13053A1732013-02-21021 February 2013 Email, Draft Request for Additional Information, Nos. 53-67, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter Project stage: Draft RAI ML13053A1842013-02-21021 February 2013 Draft Request for Additional Information, Nos. 53-67, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter Project stage: Draft RAI ML13058A0262013-02-25025 February 2013 Response to Request for Additional Information (Rals 2, 3, and 4) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13056A6012013-02-25025 February 2013 Response to Request for Additional Information (RAI 32) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13059A1572013-02-27027 February 2013 Licensee Slides from 2/27/13 Meeting Regarding a Request for Additional Information Project stage: Meeting ML13059A1522013-02-27027 February 2013 NRC Meeting Slides from 2/27/13 Public RAI Meeting Project stage: RAI ML13074A7932013-03-14014 March 2013 Operational Assessment for 100% Power Case Regarding Confirmatory Action Letter Response Project stage: Other 2013-01-25
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000361/20240052024-10-0404 October 2024 NRC Inspection Report 05000361/2024005 and 05000362/2024005 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status IR 07200041/20244012024-08-16016 August 2024 San Onofe Nuclear Generating Station, Security Baseline Inspection Report 07200041/2024401 IR 05000361/20240042024-08-0909 August 2024 NRC Inspection Report 05000361/2024004 and 05000362/2024004 ML24191A2472024-07-0202 July 2024 (Songs), Units 1, 2, and 3, and the Independent Spent Fuel Storage Installation - Revision to the ISFSI-Only Emergency Plan and Associated Changes to Emergency Plan Implementing Procedures ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24141A0802024-05-15015 May 2024 (Songs), Units 1, 2 and 3 and Independent Spent Fuel Storage Installation - 2023 Annual Radiological Environmental Operating Report IR 05000361/20240022024-04-0101 April 2024 – NRC Inspection Report 050-00361/2024-002 and 050-00362/2024-002 ML24094A0642024-03-27027 March 2024 Independent Spent Fuel Storage Installation, Decommissioning Funding Status Report 2023 ML24065A0152024-02-28028 February 2024 Generation Station Units 1, 2 and 3, Annual Radioactive Effluent Release Report for Independent Spent Fuel Storage Installation 2023 ML24044A0812024-02-14014 February 2024 LTR-24-0008: NRC Response to Paul Blanch Email Safety of Spent Nuclear Fuel at SONGS ISFSI IR 05000361/20240012024-02-13013 February 2024 NRC Inspection Report 050-00361/2024-001 and 050-00362/2024-001 (1) ML24037A0542024-01-30030 January 2024 (Songs), Units 2 and 3, Submittal of Annual Corporate Financial Reports ML24022A1492024-01-17017 January 2024 Independent Spent Fuel Storage Installation, Revision 4 to the Physical Security Plan ML24017A2432024-01-15015 January 2024 LTR-24-0008 Paul Blanch, E-mails Request for Formal Response to Requests for Meeting to Discuss Safety Issues with NRC Staff IR 05000361/20230062023-11-29029 November 2023 NRC Inspection Report 05000361/2023-006 and 05000362/2023-006 ML23333A0682023-11-22022 November 2023 (SONGS) Units 1, 2, 3 and Independent Spent Fuel Storage Installation - Notification of Change in Nuclear Officer IR 05000361/20230052023-10-11011 October 2023 NRC Inspection Report 05000361/2023005 and 05000362/2023005 ML23276A5942023-09-28028 September 2023 And Independent Spent Fuel Storage Installation - Supplement to Decommissioning Funding Status Reports ML23268A0922023-09-20020 September 2023 Generation Station, Units 1, 2 and 3, and the Independent Spent Fuel Storage Facility (ISFSI) - Re-Registration of Dry Fuel Storage Casks for Amended Certificate of Compliance No. 1040 IR 05000361/20230012023-09-13013 September 2023 NRC Inspection Report 05000361 2023-001 and 05000362 2023-004 ML23240A5372023-08-18018 August 2023 Confirmatory Survey Activities Summary and Results for the Unit 2 and 3 Intake Structures at the San Onofre Nuclear Generating Station San Clemente CA ML23129A1802023-06-14014 June 2023 Cover Letter to State of CA on Draft EA Regarding San Onofre ISFSI Updated DFPs IR 05000361/20230032023-05-31031 May 2023 NRC Inspection Report 05000361/2023003 and 05000362/2023003 IR 05000361/20230022023-05-23023 May 2023 NRC Inspection Report 05000361/2023-002 and 05000362/2023-002 ML23137A1032023-05-11011 May 2023 (Songs), Units 1, 2 and 3, and Independent Spent Fuel Storage Installation - 2022 Annual Radiological Environmental Operating Report ML23123A0932023-04-28028 April 2023 (Songs), Units 1, 2 and 3, Submittal of Annual Radioactive Effluent Release Report - 2022 ML23230A0882023-04-10010 April 2023 Independent Spent Fuel Storage Installation - Decommissioning Quality Assurance Plan ML23094A1272023-03-29029 March 2023 Independent Spent Fuel Storage Installation - 10 CFR 50.82(a)(8)(v and VII) and 10 CFR 72.30(c) Decommissioning Funding Status Report 2021 ML23094A1332023-03-29029 March 2023 Nuclear Property Insurance ML23062A1172023-02-28028 February 2023 Generation Station Units 1, 2 and 3, Annual Radioactive Effluent Release Report for Independent Spent Fuel Storage Installation - 2022 ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML23059A2812023-02-22022 February 2023 (Songs), Units 1, 2 and 3, 2022 Annual Turtle Incidental Take Report ML23046A3792023-02-22022 February 2023 NRC Inspection Report 050-00361/2023-001 and 050-00362/2023-001 ML23045A2022023-02-0909 February 2023 Submittal of Annual Corporate Financial Reports for San Onofre Nuclear Generating Station (SONGS) Units 2 and 3 for Fy Ending June 30, 2022 ML22287A1352023-01-0505 January 2023 Issuance of Exemption from Title 10 of the Code of Federal Regulations Part 72.106(B), Independent Spent Fuel Storage Installation Controlled Area Boundary (L-2021-LLE-0056) ML22348A0622023-01-0404 January 2023 NRC to SCE, Transmittal of the National Marine Fisheries Services December 12, 2022, Letter of Concurrence for Decommissioning of San Onofre Nuclear Generating Statiion, Units 2 and 3 IR 05000206/20220062022-12-15015 December 2022 NRC Inspection Report 05000206/2022006, 05000361/2022-006, and 05000362/2022-006 ML22347A2122022-12-12012 December 2022 NMFS to NRC, Endangered Species Act Section 7(a)(2) Concurrence Letter for Decommissioning of the San Onofre Nuclear Generating Station ML22340A6652022-12-0505 December 2022 Letter from John Fassell, Chief; Re., State of California Department of Public Health Review and Comments on SONGS Draft Environmental Assessment ML22333A8192022-11-21021 November 2022 Submittal of San Onofre Nuclear Generating Station, Units 2 and 3, Defueled Safety Analysis Report, Revised November 2022 IR 05000361/20220052022-11-17017 November 2022 – NRC Inspection Report 05000361/2022-005 and 05000362/2022-005 ML22301A1462022-10-20020 October 2022 Report of Violations of the National Pollutant Discharge Elimination System Permit San Onofre Nuclear Generating Station (Songs), Units 2 and 3 ML22277A0162022-09-29029 September 2022 Independent Spent Fuel Storage Installation Response to Request for Additional Information Regarding Request for Exemption from 10 CFR 72.106(b) IR 05000361/20220042022-09-26026 September 2022 NRC Inspection Report 05000361/2022-004 and 05000362/2022-004 ML22238A0552022-08-29029 August 2022 U.S. Nuclear Regulatory Commissions Analysis of Southern California Edisons Decommissioning Funding Status Report for San Onofre Nuclear Generating Station, Units 1, 2, and 3 ML22234A1602022-07-31031 July 2022 Final Report Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 18CLVS431 ML22207B8612022-07-26026 July 2022 NRC (Public) Inspection Report 05000361/2022003; 05000362/2022003 IR 05000361/20220032022-07-26026 July 2022 NRC Inspection Report (Public) 05000361-2022003 and 05000362-2022003 (002) IR 05000361/20220022022-05-12012 May 2022 NRC Inspection Report 05000361/2022-002 and 05000362/2022-002 2024-09-18
[Table view] |
Text
SOUTHERN CALIFORNIA Richard 1. St. OngeE DISON Director, Nuclear Regulatory Affairs and.EEmergency PlanningAn EDISON INTERNATIONAL CompanyApril 16, 2013 10CFR50.4U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001
Subject:
Docket No. 50-361Response to Request for Additional Information (RAI 71) RegardingConfirmatory Action Letter Response(TAC No. ME 9727)San Onofre Nuclear Generating Station, Unit 2
References:
1. Letter from Mr. Elmo E. Collins (USNRC) to Mr. Peter T. Dietrich (SCE), datedMarch 27, 2012, Confirmatory Action Letter 4-12-001, San Onofre NuclearGenerating Station, Units 2 and 3, Commitments to Address Steam GeneratorTube Degradation2. Letter from Mr. Peter T. Dietrich (SCE) to Mr. Elmo E. Collins (USNRC), datedOctober 3, 2012, Confirmatory Action Letter -Actions to Address SteamGenerator Tube Degradation, San Onofre Nuclear Generating Station, Unit 23. Letter from Mr. Richard J. St. Onge (SCE) to Document Control Desk(USNRC), dated February 25, 2013, Response to Request for AdditionalInformation (RAIs 2, 3 and 4) Regarding Confirmatory Action Letter Response,San Onofre Nuclear Generating Station, Unit 24. Email from Mr. James R. Hall (USNRC) to Mr. Ryan Treadway (SCE), datedMarch 15, 2013, Request for Additional Information (RAls 68-72) RegardingResponse to Confirmatory Action Letter, San Onofre Nuclear GeneratingStation, Unit 2
Dear Sir or Madam,
On March 27, 2012, the Nuclear Regulatory Commission (NRC) issued a Confirmatory ActionLetter (CAL) (Reference 1) to Southern California Edison (SCE) describing actions that the NRCand SCE agreed would be completed to address issues identified in the steam generator tubesof San Onofre Nuclear Generating Station (SONGS) Units 2 and 3. In a letter to the NRC datedOctober 3, 2012 (Reference 2), SCE reported completion of the Unit 2 CAL actions andincluded a Return to Service Report (RTSR) that provided details of their completion.SCE provided the response to RAls 2, 3 and 4 in a letter dated February 25, 2013(Reference 3). By e-mail dated March 15, 2013 (Reference 4), the NRC issued Requests forAdditional Information (RAIs) regarding the response to RAIs 2, 3 and 4. Enclosure 1 of thisletter provides the response to RAI 71.P.O. Box 128San Clemente, CA 92672 Document Control. Desk April 16, 2013There are no new regulatory commitments contained in this letter. If you have any questions orrequire additional information, please call me at (949) 368-6240.Sincerely,
Enclosure:
- 1. Response to RAI 71cc:A. T. Howell III, Regional Administrator, NRC Region IVJ. R. Hall, NRC Project Manager, SONGS Units 2 and 3G. G. Warnick, NRC Senior Resident Inspector, SONGS Units 2 and 3R. E. Lantz, Branch Chief, Division of Reactor Projects, NRC Region IV ENCLOSURE 1SOUTHERN CALIFORNIA EDISONRESPONSE TO REQUEST FOR ADDITIONAL INFORMATIONREGARDING RESPONSE TO CONFIRMATORY ACTION LETTERDOCKET NO. 50-361TAC NO. ME 9727Response to RAI 71 RAI 71Reference 1, Response to RAI 2 -It is stated on page 4 of 18 that a median value of initiationtime was selected for each tube based on 1000 trials. For purposes of evaluating aconservative probability estimate that one or more tubes do not meet the 3 delta P criterion, whyis it conservative to consider a median value of initiation time for each tube, rather thansampling from the distribution of initiation times developed for each tube during a given MonteCarlo trial of the tube population? Would sampling the distribution of initiation times for eachtube be a more conservative approach, as it would be expected to stretch out the tails of theresulting overall probability distribution for not meeting the 3 delta P criterion? For aprobabilistic assessment such as this, what is the justification for not considering a potentiallylarge source of uncertainty associated with a key input parameter?RESPONSENote: RAI Reference 1 is SCE's "Response to Request for Additional Information (RAIs 2, 3,and 4) Regarding Confirmatory Action Letter Response," dated February 25, 2013.The industry guidelines were followed in performing the tube integrity calculations to meet thestructural integrity performance criteria (SIPC) margin requirements of three times normaloperating pressure differential (Reference R1). The performance acceptance standard forassessing tube integrity requires the worst-case degraded tube to meet the SIPC marginrequirements with a probability of 0.95 at 50% confidence (Section 2.4 in Reference R1). Thetechnical basis for the 95-50 performance standard is documented in Reference R2. Inputdistributions for probabilistic components of the analysis such as degradation growth rates areallowed to be best estimates.Why is it conservative to consider a median value of initiation time for each tube, ratherthan sampling from the distribution of initiation times developed for each tube during agiven Monte Carlo trial of the tube population?A median value of initiation time was selected to provide a conservative (higher) estimate oftube to tube wear (TTW) growth rate in the model used to respond to RAI 2. Sampling thedistribution of initiation times for each tube would result in an earlier estimate (maximumlikelihood) of TTW initiation and a corresponding lower -T-w growth rate.In response to this RAI, Intertek completed an analysis of the simulation model output results todemonstrate that the use of median TTW initiation times adequately models the distribution ofall TTW initiation times. The analysis simulation results allowed an evaluation of the relativelikelihood for the initiation time for each instance of TTW for each tube. The maximumlikelihood for a distribution is determined from the mode of the distribution. Figure 1 illustratesthe mode of a distribution for the TTW initiation times calculated for a typical tube (R90 C84 in3E-088). For a simulated population, the sample mode represents the maximum likelihoodestimate (greatest chance to occur) and is the peak location of the histogram. The initiationtime defined by the mode is the most likely outcome for that tube from the simulation. Alsoshown in Figure 1 is the median value for the same sample distribution. The sample median isthe value where 50% of the occurrences fall to either side of that value when the results areranked in ascending order. For the majority of the tubes with TTW, the median value of eachtube-specific sample provided an initiation time that occurred later in the operation cyclecompared to the mode value. This resulted in a higher TTW growth rate which is morePage 2 of 6 conservative when calculating the final depth of TTW and the resulting probability of meeting the3 delta P criterion. Approximately 85% of the tubes showed this behavior where the medianinitiation time was typically less than 0.2 years at power. Examples of tubes that had a strongbias towards early initiation times are shown in Figure 2a.Approximately 10% tubes had initiation times mid-way through the cycle as shown in Figure 2b.In this case, the median value and the mode value are essentially the same and the resultingTTW growth rates are no different between the median and mode value cases.Tubes with initiations beyond mid-cycle are shown in Figure 2c. For very few tubes, typicallytubes with very low wear indices and/or few affected AVBs, results give very late initiation timesand unrealistically high TTW growth rates. These occurrences are not strongly related tothe AVB wear index and are more likely caused by impacts from unstable neighbor tubes.There were only a few instances (less than 5%) where this was observed.Would sampling the distribution of initiation times for each tube be a more conservativeapproach, as it would be expected to stretch out the tails of the resulting overallprobability distribution for not meeting the 3 delta P criterion?The corresponding distributions developed from the initiation times (all simulated values vs.median values) are plotted together in Figure 3. Figure 3 illustrates the global distributionof TTW initiation times for each Unit 3 steam generator. It can be seen that the two distributionsare comparable. This is a direct consequence of the diversity in distributional form exhibited bythe individual tube initiation time samples shown in Figure 2.Because of the diversity among the individual tubes, the cumulative distribution for medianinitiation times covers the full range of this key parameter including the upper extremes. It is notexpected that sampling the distribution of individual initiation times for each tube would besignificantly more conservative since the tails of the simulated population are represented by thedistribution of the median times.For a probabilistic assessment such as this, what is the justification for not consideringa potentially large source of uncertainty associated with a key input parameter?The median estimates based on 322 calculated values adequately represent the range ofuncertainty in initiation times from the full set of calculations (322,000 values). The ability of thedistribution of median times to produce a similar distributional behavior for the full simulateddata justifies its use in the OA. The potential source of uncertainty associated with the TTWinitiation times is considered and included in the assessment.REFERENCESRI. "Steam Generator Integrity Assessment Guidelines," Revision 3, Electric Power ResearchInstitute, EPRI Report 1019038, (November 2009).R2. "Technical Basis for Steam Generator Tube Integrity Performance Acceptance Standards,"EPRI, Palo Alto, CA: 2006. 1012984.Page 3 of 6 Histogram of Initiation Times2501I250200SaplModeSamplMediaI ITube R90 C84 Distribution0Ez150100 -so I-n -.0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9Initiation Time (Yearn at Power)Figure 1 -Sample Median and Mode for a Typical Tube Histogram1.0Page 4 of 6 300U250o 2001Iso100Ua) .... ............Initiation Times (Years at Power)200180-140-120-100-so-EZ 4Oz Go-4020-0"b)IniUaton Times (Years at Power)200ISO F.Rl124-180a 140a120-o 100so-E4020 lC) &0Initiation Times (Years at Power)Figure 2 -TTW Initiation Times from the Simulation for Selected Tubesin 3E-088Page 5 of 6 3E-088ILU.0Z7NU-0.04 I I i0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0Initiation Time, (Years at Power)3E-0891.00.90.8U.0.70z 0.6ILaC0 0.50..o 0.4U5 0.3S0.20.10.00.0 0.1 0.2 0.3 0.4 0.5 0.6Initiation Time, (Years at Power)0.7 0.8 0.9 1.0Figure 3 -Cumulative Distributions for Initiation Times (Median vs. All Data)Page 6 of 6