Responds to Request to Use Code Case N-509 as Alternative to ASME Code Section XI for Crystal River Nuclear Plant,Unit 3. Evaluation of Relief Request Determined Use of Code Case N-509 Provides Acceptable Level of Quality & Safety.Se Encl
ML20138E426
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 04/30/1997
From: Hebdon F
NRC (Affiliation Not Assigned)
To: Richard Anderson
FLORIDA POWER CORP.
Shared Package
ML20138E430 List:
References
TAC-M98261, NUDOCS 9705020195
Download: ML20138E426 (2)


Text

3 1

Mr. Pay A. Anderson l Senior Vice President, Nuclear Operations April 30,1997 l Florida Power Corporation ATTN: Manager, Nuclear Licensing (SA2A)

Crystal River Energy Complex 15760 W Power Line Street Crystal River, Florida 34428-6708

SUBJECT:

REQUEST TO USE CODE CASE N-509 AS AN ALTERNATIVE TO ASME CODE SECTION XI FOR CRYSTAL RIVER NUCLEAR PLANT, UNIT 3 (TAC NO. M98261) 1

Dear Mr. Anderson:

1 1

Regulatory Guide, 1.147, Inservice Inspection Code Case Acceptability ASME '

Section XI, Division 1, Revision 11, dated October 1994, lists those Section XI ASME Code Cases that are generally acceptable to the NRC staff for implementation in the inservice inspection of light-water-cooled nuclear power I plants. Code Case N-509, " Alternative Rules for the Selection and Examination of Intergrally Welded Attachments,Section XI, Division 1," is not included in the NRC Regulatory Guide 1.147.

By letter dated March 24, 1997, you submitted Relief Request (RR) 97-001-II.

Pursuant to 10 CFR 50.55a(a)(3)(i), you requested approval for implementing Code Case N-509 for certain surface and volumetric examination of integral attachment welds in Classes 1, 2 and 3 piping.

We have evaluated your relief request and determined that use of Code Case N-509 would provide an acceptable level of quality and safety and, therefore, is authorized pursuant to 10 CFR 50.55a(a)(3)(1) and is acceptable. Please be advised that use of Code Case N-509 is acceptable until such time as it may be included in a future revision of Regulatory Guide 1.147. At that time, you should follow any provisions and limitations that may be described in the Regulatory Guide 1.147 concerning the use of Code Case N-509.

Our evaluation and conclusions are contained in the attached safety evaluation. This completes our effort under Technical Assignment Control (TAC) No. M98261 and the TAC is closed.

Sincerely, Original signed by Frederick J. Hebdon, Director rg, i QQ* h h h Project Directorate II-3 Division of Reactor Projects - I/II l Office of Nuclear Reactor Regulation  !

Docket No. 50-302 Distribution Docket File T. Harris (E-Ma;l

Enclosure:

Safety Evaluation PUBLIC SE only)

Crystal Rdg. File OGC cc w/ enclosure: See next page SVarga ACRS DOCUMENT NAME: G:\ CRYSTAL \98261.rel JZwolin ski J. Johnson, RIl To receive a copy of this document, indicate in the box: "C" - Copy without TMcLellan attachment / enclosure "E" o Copy with attachment / enclosure "N" - No copy

  • See previcos OFFICE PDl! 3/PM .m l -

PDII 3/LA .,jl l PDil-3/D i) lC- OGC* l l ECGB/DE* l NAME LRaghavan LD BClayton NF FHebdon W' MYoung GBagchi DATE 4 / 2Qt L4 4/ 0/ 9 r1 4 /M /47 04/25/97 04/14/97 i OFFICIAL RECORD COPY 9705020195 970430 PDR ADOCK 05000302 'I P PDR l

I Florida Power Corporation CRYSTAL RIVER UNIT NO. 3 GENERATING PLANT l

CC: i Mr. R. Alexander Glenn Senior Resident Inspector Corporate Counsel Crystal River Unit 3 Florida Power Corporation U.S. Nuclear Regulatory Commission MAC-ASA 6745 N. Tallahassee Road ,

P.O. Box 14042 Crystal River, Florida 34428 l St. Petersburg, Florida 33733-4042 Regional Administrator, Region II Mr. Bruce J. Hickle, Director U.S. Nuclear Regulatory Commission i Nuclear Plant Operations (NA2C) 101 Marietta Street NW., Suite 2900 l Florida Power Corporation Atlanta, Georgia 30323 l Crystal River Energy Complex  !

15760 W. Power Line Street Mr. John P. Cowan '

Crystal River, Florida 34428-6708 Vice President - Nuclear Production (SA2C)

Mr. Robert B. Borsum Florida Power Corporation B&W Nuclear Technologies Crystal River Energy Complex 1700 Rockville Pike, Suite 525 15760 W. Power Line Street Rockville, Maryland 20852 Crystal River, Florida 34428-6708 Mr. Bill Passetti Mr. Roy A. Anderson Office of Radiation Control Senior Vice President, Department of Health and Nuclear Operations Rehabilitative Services Florida Power Corporation 1317 Winewood Blvd. ATTN: Manager, Nuclear Licensing Tallahassee, Florida 32399-0700 Crystal River Energy Complex (SA2A) 15760 W. Power Line Street Attorney General Crystal River, Florida 34428-6708 Department of Legal Affairs The Capitol Mr. Kerry Landis Tallahassee, Florida 32304 U.S. Nuclear Regulatory Commission 101 Marietta Street, NW. Suite 2900 Mr. Joe Myers, Director Atlanta, Georgia 30323-0199 Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 Chairman Board of County Commissioners Citrus County 110 North Apopka Avenue Iverness, Florida 34450-4245 Mr. David F. Kunsemiller, Director Nuclear Operations Site Support (SA2A)

Florida Power Corporation Crystal River Energy Complex 15760 W. Power Line Street Crystal River, Florida 34428-6708