Insp Repts 50-250/85-37,50-260/85-37 & 50-296/85-37 on 850729-0802.Major Areas Inspected:Security Plan & Implementing Procedures,Security Organization & Testing & Maint.Details Withheld (Ref 10CFR2.790 & 73.21)
ML20134J355
Person / Time
Site: Browns Ferry, Turkey Point  Tennessee Valley Authority icon.png
Issue date: 08/22/1985
From: Mcguire D, Moore D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20134J347 List:
References
50-259-85-37, 50-260-85-37, 50-296-85-37, NUDOCS 8508290258
Download: ML20134J355 (1)


See also: IR 05000729/2008002

Text

! SAFF. GUARDS INFORMATiON <

  • UNITED STATES

NUCLEAR REGULATORY COMMISSION

i

'

y[A9 K8tg]o , REGloN il

g j 101 MARIETTA STREET.N.W.

  • ' * AT L ANT A, GEORGI A 30323

\ . . . . . '# AU6 2 31985

Report N 2. 50-259/85-37, 50-260/85-37 and 50-296/85-37

Licensee: Tennessee Valley Authority

500A Chestnut Street, Tower II

Chattanooga, TN 37401

Docket Nos. 50-259; 50-260 and 50-296 License Nos. DPR-33, DPR-52 and DPR-68

Facility Name: Browns Ferry Units 1, 2 and 3

Inspection Conducted: July 29 - August 2, 1985

Inspect r: mA c _

D T M6 ore; Physical Security Inspector

7bl[f6

D&te $1gned

Approved by: d \. A JMf

D. R. McGuirf, Chief, Ph ical Security Section Date Signed

Nuclear Matefials Safety nd Safeguards Branch

Division of Radiation Safety and Safeguards

SUMMARY

Scope: This routine, unannounced inspection involved 33 inspector-hours on site

(three hours on backshift) inspecting: Security Plan and Implementing Proce-

dures; Security Organization; Security Program Audit; Testing and Maintenance;

Locks, Keys, and Combinations; Physical Barriers - Protected / Vital Areas;

Security System Power Supply; Lighting; Assessment Aids; Access Control -

Packages / Vehicles; Detection Aids - Protected / Vital Areas; Alarm Stations; and

Communications.

Results: No violations or deviations were identified.

<

!

05002%g8508@2$59

w OSO

PDN PDft

EHCLOSURE CONTAINS

SAFECUARDS INFORMATIO

UPON SEPARATI

<

SAFEGUARDS INFORMATION **** 2' ***=ON'88-'IHIS