Forwards LER 96-004-03 Re TS Surveillance Procedure Review for Identification of Inadequate Surveillance Testing,Per GL 96-01
ML17354A404
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 02/03/1997
From: HOVEY R J
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17354A405 List:
References
GL-96-01, GL-96-1, L-97-24, NUDOCS 9702100491
Download: ML17354A404 (2)


Text

~CATEGORY REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)ACCESSION NBR,:9702100491 DOC.DATE: 97/02/03 NOTARIZED:

NO DOCKET FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 05000250 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C 05000251 AUTH.NAME AUTHOR AFFILIATION HOVEY,R.J.

Florida Power a Light Co.RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards LER 96-004-03,documenting event that occurred at Turkey Point, Units 3&4 on 960513 util commitments made within ltr,listed.

DISTRIBUTION CODE: ZE22T COPIES RECEIVED:LTR 1 ENCI i SIZE:+I F TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.NOTES: INTERNAL: RECIPIENT ID CODE/NAME PD2-3 PD ILE CENTER B NRR/DRCH/HHFB NRR/DRCH/HOLB NRR/DRPM/PECB NRR/DSSA/SRXB RGN2 FILE 01 COPIES LTTR ENCL 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RECIPIENT ID CODE/NAME CROTEAU,R AEOD/SPD/RRAB NRR/DE/ECGB NRR/DE/EMEB NRR/DRCH/HICB NRR/DRCH/HQMB NRR/DSSA/SPLB RES/DET/EIB COPIES LTTR ENCL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 EXTERNAL: L ST LOBBY WARD NOAC POORE,W.NRC PDR 1 1 1 1 1 1 LITCO BRYCEPJ H NOAC QUEENER,DS NUDOCS FULL TXT 1 1 1 1 1 1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN SD-5(EXT.415-2083)TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR 24 ENCL 24 FEB 31997 L-97-24 10 CFR 50.73 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.20555 Re: Turkey Point Units 3&4 Docket Nos.50-250&50-251 Reportable Event: 96-004-03 Technical Specification Surveillance Procedure Review-Idcntification of Inadc uate Surveillance Tcstin By letter L-96-068, dated March 18, 1996, as revised by L-96-115, dated May 13, 1996, Florida Power and Light Company (FPL)submitted Licensee Event Report (LER)250/96-004-01, Inadequate Surveillance of the Auxiliary Fccdwater Actuation Circuitry.

This LER documented thc first condition identified under thc Tcchnical Specification Surveillance Review Program in response to Generic Letter (GL)96-01,"Testing of Safety-Rclatcd Logic Circuits." By letter L-96-147, dated Junc 18, 1996, FPL submitted LER 250/96-004-02, Identification of Inadequate Surveillance Testing, to document the second condition under the Technical Specification Surveillance Review Program in response to GL 96-01, regarding inadequate surveillance of thc 4KV D Bus clearing function.The attached revised LER, 250/96-004-03, documents thc third condition idcntificd under this continuing program, regarding inadequate surveillance procedures for thc main steam linc isolation function.The revised LER, 250/96-04-3, is being provided in accordance with 10 CFR 50.73(a)(2)(v).

FPL will report any future cvcnt identified as a result of thc GL 96-01 review as a supplement to LER 250/96-004.

If there are any questions, please contact us.Very truly yours, R.J.Hovcy Vice President Turkey Point Plant CLM attachment cc: Luis A.Reycs, Regional Administrator, Region II, USNRC Thomas P.Johnson, Senior Rcsidcnt Inspector, Turkey Point Plant, USNRC 9702100491 970203 PDR ADOCK 05000250 PDR an Fpi.Group conrpanr