Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML19325E63327 October 1989LER 89-014-00:on 890929,RWCU Sys Isolated on Simulated Steam Line Tunnel High Temp Signal.Caused by Operator Failure to Perform self-verification Prior to Moving Bypass Switch. General Manager Held Briefings w/personnel.W/891027 Ltr
ML19325E69731 October 1989LER 89-008-02:on 890523,two Redundant Secondary Containment Isolation Dampers Failed to Close within 4 Time Limit of Tech Spec 3.6.6.2.Caused by Malfunction of Exhaust Valves. Exhaust Valve replaced.W/891031 LtrStroke time
ML19332F07329 November 1989LER 89-015-00:on 891030,no Data or Evidence Found for Stroke Time Test Required to Be Performed Following Maint on Bettis Actuator for Isolation Damper QSZ51F001.Caused by Personnel Error.Programmatic Enhancements initiated.W/891129 LtrTime of Discovery
Stroke time
ML20005D7416 December 1989LER 89-016-00:on 891107,during Severe Thunderstorm,Lightning Struck Site,Causing Scram & HPCS Low Water Level Channels to Trip.Design Change Package Issued to Install Lightning Dissipation Sys on Vulnerable structures.W/891206 Ltr
ML20005G20712 January 1990LER 89-018-00:on 891215,design Basis Review of Instrumentation Determined That 71 Devices,Classified as nonsafety-related,contained in Class 1E Circuits.Caused by Level of Control on Instrument index.W/900112 Ltr
ML20005G21212 January 1990LER 89-007-01:on 890508,RWCU Sys Isolated on Leak Detection Differential Flow Signal While Shifting RWCU Operation from pre-pump to post-pump Mode.Probably Caused by Inadequate Reactor Pressure.Procedure revised.W/900112 Ltr
ML20006B27816 January 1990LER 89-017-00:on 890718,determined That Isolation for Postulated RWCU Blowdown Line Breaks in Piping Cold Rooms Was 80 S,Causing Plant to Operate in Unanalyzed Condition. Tech Spec Change Request Will Be submitted.W/900116 LtrUnanalyzed Condition
ML20006B87329 January 1990LER 89-019-00:on 891230,total Loss of Plant Svc Water Experienced Due to Loss of Power to Supply Wells.Caused by Malfunction of Microwave Info & Control Sys.Periodic Microwave Operational Checks established.W/900129 Ltr
ML20006E0469 February 1990LER 90-001-00:on 900112,determined That Tech Spec Reactor Coolant Cooldown Rate Limit of 100 Degrees F Exceeded in Reactor Bottom Head Drain Pipe.Caused by Programmatic Deficiencies.Incident Rept Form improved.W/900209 LtrTime of Discovery
ML20006E45215 February 1990LER 89-015-01:on 891030,no Data or Evidence Found That Stroke Time Test Performed on Bettis Actuator for Isolation Damper Following Maint.Caused by Programmatic Weaknesses.New Computer Field Data Added to Work orders.W/900215 LtrTime of Discovery
Stroke time
ML20012A16628 February 1990LER 90-002-00:on 900124,discovered That Div II Solenoid Associated W/Secondary Containment Isolation Valve Did Not Operate During Quarterly Valve Stroke Time Tests.Caused by Procedure Inadequacy.Procedures changed.W/900227 LtrStroke time
ML20012D48016 March 1990LER 90-003-00:on 900215,identified Potential Single Failure Scenario That Could Result in Unavailability of Both Core Spray Sys for Long Term post-LOCA Core Cooling.Detailed Heatup Evaluation Performed for Power bundle.W/900316 Ltr
ML20012D80722 March 1990LER 89-018-01:on 891215,determined That Inappropriate Quality Level Designations Applied to Class 1E Circuits, in Violation of Reg Guide 1.75.Caused by Discrepant Instrument Index Controls.Handswitch replaced.W/900228 LtrEarthquake
ML20023B55428 April 1983LER 83-060/03L-0:on 830329,during Cold Shutdown,Load Shedding & Div I LSS Sequencing Panel Failure Alarm Actuated.Caused by Failure of 15-volt Dc Power Supply Used to Power Solid State Electronics for Sys Logic
ML20023B67327 April 1983LER 83-061/03L-0:on 830328,one Solenoid Operated Freon Valve Found W/Blown Gasket.Caused by Defective Alco Controls Solenoid Operated Gasket.Valve Reworked W/Valve Repair Kit & New Gasket Installed
ML20023C5519 May 1983LER 83-048/01T-0:on 830423,suppression Pool Level Instrumentation Discovered Not Functionally Tested Since 830409.Cause Under Investigation.Instrumentation Tested Satisfactorily within 8 H
ML20023C5599 May 1983Updated LER 83-031/99X-1:on 830113,fire Rated Door OC104 Blocked Open to Route Temporary Discharge Hose from Hot Machine Shop Sump to Turbine Bldg Floor Drain Sys.Caused by Inadequacy of Present Sys.Mod to Be Completed by Sept 1983
ML20023C5619 May 1983Updated LER 83-004/01T-1:on 830110,penetration AP-72B Found Open & Had Been Open Since 821213.Caused by Planned Maint Work & Personnel Error.Hourly Fire Watch Established. Penetration to Be Resealed by 830630Fire Watch
Hourly Fire Watch
ML20023D2519 May 1983LER 83-049/03L-0:on 830409,during Cold Shutdown,Diesel Generator 12 Auto Start Not Available When Alarm Actuated. Caused by Condensate Drain Valve Downstream of Tank C Not Fully Closed.Compressors Reworked
ML20023D43312 May 1983LER 83-046/03L-0:on 830412,monthly Functional Surveillance for Div I Chlorine Detection Sys Not Performed by 830410. Caused by Personnel Error
ML20023D47711 May 1983LER 83-052/03L-0:on 830411,while Reviewing Vessel Head Installation Work Package,Discovered Head Flange/Vessel Flange Thermocouples Not Physically Reinstalled During Insulation Installation.Cause Under Evaluation
ML20023E04427 May 1983Updated LER 83-058/01X-1:on 830311,discovered That Fire Watches Not Conducted in Two Areas of Fire Detection Zone 2-19.Limiting Conditions for Operation Entered on 830227. Caused by Personnel Oversight.Zone restored.W/830527 LtrFire Watch
Hourly Fire Watch
ML20024B99429 June 1983LER 83-072/01T-0:on 830615,operations Shift Supervisor Discovered Some Continuous Fire Watches Not Performed on 830614.Caused by Personnel Error.Personnel Reinstructed Not to Pull Fire Watch W/O approval.W/830629 LtrContinuous fire watch
Fire Watch
ML20024B99824 June 1983LER 83-070/03L-0:on 830525,reactor Water Cleanup Sys Isolated When Standby Liquid Control Pump B Breaker Closed. Caused by Personnel Error.Isolation Signal reset.W/830624 Ltr
ML20024C31222 June 1983LER 83-069/03L-0:on 830523,during Attempt to Reenergize Div II Motor Operated Valves,Shutdown Cooling Mode of RHR Sys & Reactor Water Cleanup Sys Isolated.Caused by Failure to Install Power Fuses.Fuses installed.W/830622 Ltr
ML20024C40327 June 1983LER 83-071/03L-0:on 830607,RHR Shutdown Cooling Mode Isolated When Valve E12-F009 Closed.Caused by Blown Fuse. Fuse replaced.W/830627 Ltr
ML20024D07625 July 1983LER 83-080/03L-0:on 830626,control Room Operators Experienced Problems W/Hvac Sys Involving Inadequate Cooling Capacity & Sys Losses.Partially Caused by Malfunctioning Condenser Cooling Water Flow Control valve.W/830725 Ltr
ML20024D08925 July 1983LER 83-079/03L-0:on 830625,auxiliary Trip Unit for High Drywell Pressure Indicated Trip Condition Yet No Reactor Protection Sys Trip Occurred.Caused by Defective Rosemount Auxiliary Trip Unit.Trip Unit replaced.W/830725 Ltr
ML20024D87829 July 1983LER 83-078/03L-0:on 830701,control Room Operators Unable to Maintain Air Receiver Pressure for Diesel Generator 11. Caused by Setpoint Drift on Relief Valves for diesel-driven & Electric motor-driven Air compressors.W/830729 Ltr
ML20024E87431 August 1983LER 83-108/01T-0:on 830817,radiation Monitor B Trip Setpoint Found High & Grab Samples & Analyses Started Late.Caused by Personnel Error.Personnel counseled.W/830831 LtrGrab sample
ML20024E91130 August 1983Updated LER 83-097/03X-1:on 830720,reactor Water Cleanup Auto Isolation Occurred.Caused by Delta Temp Channel B Indicating Temp Above Trip Point Limit.Investigation continuing.W/830830 Ltr
ML20024E93129 August 1983Updated LER 83-002/01X-1:on 830114,personnel Discovered Heat Detectors in Control Room Standby Fresh Air Sys Not Functionally Tested.Caused by Lack of Proper Procedure. Procedure rewritten.W/830829 LtrMissed surveillance
Fire Watch
Hourly Fire Watch
ML20024F20929 August 1983LER 83-111/03L-0:on 830730,during Performance of Work Order to Correct Malfunction W/Div I Isolation Reset Status lights,amphenol-type Signal Cable Connector in C/R Panel Disconnected.Caused by Personnel error.W/830829 Ltr
ML20024F45631 August 1983Updated LER 83-001/01X-2:on 830107,electrician Preparing to Route Cable Noticed Two Wall Penetrations Had Been Opened. Because Control Room Not Notified of Work,No Fire Watch in Effect.Caused by Personnel error.W/830831 LtrFire Watch
Hourly Fire Watch
ML20024F50929 August 1983LER 83-112/03L-0:on 830730,while Troubleshooting Initiation Circuitry to Find Reason for Improper Operation of E12F087B & F025B,partial LOCA Signal Occurred.Caused by Error in Work Order.Administrative Fix underway.W/830829 Ltr
ML20024F60729 August 1983Updated LER 82-050/99X-1:on 820806,Fire Detection Zone 2-10 Went Into Alarm Condition & Would Not Clear.Caused by Diesel Exhaust Fumes Drifting Into Corridor.Detectors Cleaned. Design Change submitted.W/830829 LtrFire Watch
ML20024F61329 August 1983Updated LER 83-010/99X-2:on 830105,fire Protection Deficiencies on Redundant Raceways/Cables Discovered in Auxiliary,Turbine & Control Bldgs.Caused by Incomplete Const.Maint Work Now complete.W/830829 Ltr
ML20024G9706 May 1991LER 91-002-00:on 910406,operating Module Breaker in Automatic Turbine Tester Circuitry Tripped Open,Deenergizing Control Solenoid for change-over Valve.Caused by Use of Undersized Circuit Breaker.Module replaced.W/910506 Ltr
ML20027B2119 September 1982LER 82-036/03L-0:on 820803,zone 1-23 Smoke Detector in Upper Cable Spreading Room Deactivated Via Security Computer.Caused by Spurious Alarm W/O Smoke or Fumes.Hourly Fire Watch Established.Smoke Detector Cleaned & ResetHourly Fire Watch
ML20027B36713 September 1982LER 82-050/99X-0:on 820806,early Indication by Fire Detection Sys Covering HPCS Diesel Generator Room & Fresh Air Corridor Progressed Into Alarm State & Would Not Clear. Caused by Dirt in Ionization Detectors.Detectors CleanedFire Watch
ML20027B76022 September 1982LER 82-059/01T-0:on 820909,setpoints for RHR Injection Valve Differential Pressure Switches Found High.Caused by Erroneous Procedure Listing Setpoint as 58 Psig Vs 43 Psig. Change Issued to Correct Procedures
ML20027B81322 September 1982LER 82-061/03L-0:on 820830,smoke Detector Zone Covering Standby Svc Water Pumphouse Alarmed & Would Not Clear.Caused by Dust Contamination of Ionization Smoke Detectors. Detectors CleanedFire Watch
ML20027B87322 September 1982LER 82-058/03L-0:on 820823,control Room Fresh Air Units a & B Not Fully Operable Due to Failure of Filter Train Heater to Energize.Caused by Failure of Air Flow Sensor in a & B Heater Switch When Placed in Test Position
ML20027D28428 October 1982LER 82-078/03L-0:on 821005,battery Surveillance Procedure 06-E1-1111-W-0001 Revealed Voltage on Div 1 Dc Supply to Be 121.7-volts Dc Resulting in Reduction in Electrical Reserves.Caused by Errors in Maint Instruction 07-S-12-45
ML20027D32128 October 1982LER 82-084/03L-0:on 820929,control Room Indication Lost on Plant Chilled Water Auxiliary Bldg Isolation Valve 1P71F301 During Procedure 06-OP-1P71-Q-0001 Cycling.Caused by out-of- Adjustment Limit Switch.Switch Adjusted
ML20027D41928 October 1982LER 82-093/03L-0:on 820929,routine Surveillance Procedure 06-OP-1T42-Q-0001 Revealed Fuel Handling Area Vent Supply Isolation Damper Failed to Cycle Closed in Less than 5-s. Caused by Cup Seal Being Stretched Oversize.Seal Repaired
ML20027D43713 October 1982Corrected LER 82-075/99X-0:on 820915,steam Tunnel Fire Door IA230 Found Open W/No Fire Watch Stationed.Caused by Maint Work Which Required That Fire Door Remain Open.Fire Watch Established for Duration of Maint WorkFire Watch
Hourly Fire Watch
ML20027D46328 October 1982LER 82-096/03L-0:on 821001,fire Zone 2-04 Deactivated in Security & Fire Protection Computer Due to Inability to Reset Spurious Smoke Detector Alarm.Caused by Spurious Reaction,Not Component Failure.Alarm ResetHourly Fire Watch
ML20027D52718 October 1982Corrected LER 82-085/03L-0:on 820916,three Secondary Containment Penetrations Opened for Cable Routing Per Planned Maint Activity.Hourly Fire Watch Established During Maint.Penetrations SealedHourly Fire Watch
ML20027D8985 November 1982LER 82-103/01T-0:on 821022,during Review of Documents Declaring HPCS Div III Diesel Generator Inoperative, Remaining Ac Source Operability Not Demonstrated.Caused by Personnel Error.Corrective Actions Undetermined