 Issue dateTitleTopic
ML17223A74526 January 1990Part 21 Rept Re Backup Rings Furnished in Spare Parts Seal Kits & in 25 Gpm 4 Way Valves as Part of Actuators Made of Incorrect Matl.Rings Should Be Viton & Have Been Identified as Buna N
ML19209A51928 September 1979First Deficiency Rept Re Qualification of Steam Generator & Pressurizer Power Operated Relief Valve Control Sys & Main Feedwater & Automatic Rod Control Sys.Next Rept Will Be Submitted in Approx Three Months
ML19260C95128 November 1979Final Deficiency Rept Re Gulf & Western Preassembled formation.Safety-related Preassembly Formations Will Be Reworked & Rejectable Indications in Welds Will Be CorrectedSafe Shutdown
Safe Shutdown Earthquake
ML19260D5695 February 1980Supplemental Deficiency Rept Re Control Sys Subj to Adverse Environ.Safety Analyses & Adequacy of Protective Functions Performed by safety-grade Equipment Could Be Affected.Cause Unstated.Pressure Controllers Procured
ML19262C60028 November 1979Final Deficiency Rept Re Gulf & Western Preassembled Formations.Formations Found to Include Incomplete Penetration,Incomplete Fusion & Slag Inclusions.Formations to Be ReworkedSafe Shutdown
Safe Shutdown Earthquake
ML19296C31112 February 1980Final Deficiency Rept:Vertical Fire Dampers Supplied by Ruskin Mfg Co Fail to Close Completely.Caused by Disconnection of Damper Blade Closure Spring During Cycling. Dampers Will Be Modified Per Encl DrawingsSafe Shutdown
ML19305B07512 February 1980Final Deficiency Rept Re Defective Vertical Fire Dampers. All Fire Damper Units Will Be Modified & Operationally Cycled Prior to or During Installation
ML19305B9566 December 1979Deficiency Rept:On 791107,util Informed NRC of Undetectable Failure in Engineered Safety Features Actuation Sys. Corrective Action to Detect Failure by Testing Sequence Will Be Incorporated Into Plant Procedures.Westinghouse Ltr Encl
ML19305D1915 March 1980Supplemental Part 21 Rept Re Failed Engine Thrust Bearing. Insp of Crankshaft Thrust Bearings Installed on Two PC-2.5 Generator Sets Indicate Plugs Properly Installed & Free of Reported Potential Defect.Load During Shop Tests Too Light
ML19305D6733 April 1980Interim Deficiency Rept Re Vertical Fire Dampers Furnished by Ruskin Mfg Co.Addl Problems Identified Requiring New Design Mods.Mods Being Developed & Will Be Described in Rept to Be Issued by 800515
ML19305E8038 May 1980Suppl to Final Deficiency Rept Re Ruskin Mfg Co Vertical Fire Dampers.Suggested Mod Found to Be Unacceptable. Alternate Design Mod Developed,Applied & Tested.New Problem, Re Closure of Small Dampers,Rectified
ML19309B15326 March 1980Interim Deficiency Rept Re Electrical Penetration Assembly Wire Terminations.Initiated Bunker-Ramo Insp to Determine Cause.Final Rept Will Be Submitted by 800430
ML19309G62620 March 1980Deficiency Report Re Undetectable Failure in Engineered Safety Features Actuation Sys.Licensee Investigating Hardware Changes Which May Preclude Need for Tests Described in 800215 Ltr
ML19309H6155 May 1980Final Deficiency Rept Submitted for Snupps, Rept on Improperly Crimped Lugs on Electrical Penetration Assemblies Supplied by Bunker Ramo Corp.Safe Shutdown
ML19310A40812 June 1980Supplemental Deficiency Rept Advising NRC That Addl Insp Found Penetration Wire Terminations W/Insulation Extending Into Terminal Lug Barrel & Incorrectly Sized Lugs on Wire Module.Hold on Addl Fabrication at Bunker Ramo Established
ML19312E83112 June 1980Supplements 800506 Interim Deficiency Rept Re Quality & Integrity of Penetration Wire Terminations.Addl Terminations Found W/Insulation Extending Into or Through Terminal Lug Barrel.Assessment of Bunker Ramo QA & Mgt Underway
ML19318A96116 June 1980Interim Deficiency Rept Re Surface Mounted Plates. Reinspection of Surface Mounted Plates Underway.Final Rept Will Be Issued on 800908
ML19318B09016 May 1980Forwards Bechtel 800508 Suppl to Final Deficiency Rept Re Ruskin Mfg Co Vertical Fire Dampers.Mod Proposed in 800215 Final Rept Is Unacceptable Since Number 6 Screws Could Become Loose.Ruskin Has Developed Successful Design Mod
ML19318D09330 June 1980Discusses 800620 Rept of Potential Deficiency Re Excessive Pressure in Feedwater Lines Following Postulated High Energy Line Break.Excessive Pressure Does Not Constitute Deficiency Per 10CFR50.55e
ML19322E94827 March 1980Final Deficiency Rept:Investigation in Response to IE Circular 80-01 Revealed GE Induction disc-type Relays W/ Higher than Normal Pickup Voltage.Caused by Petroleum Jelly Lubricant.Arrangements Made for GE Replacement or Mods
ML19323A9753 April 1980Interim Deficiency Rept Re Ruskin Vertical Fire Dampers.Due to Problems Identified After 800215 Rept,Addl Design Mods Are Required for Dampers & Will Be Described by 800515
ML19323D31913 May 1980Interim Deficiency Rept Re Use of Improper Preheat When Welding Pipe Supports to Heavy Structural Steel Members. Complete Evaluation by Bechtel Power Corp Is Underway.Final Rept Will Be Provided by 800731
ML19323G15219 May 1980Part 21 Rept Re Pipe Support Sway Struts W/Loose Bushings. During Seismic Event,Piping Could Be Overstressed.Struts Have Been Reworked to Correct Deficiency
ML19323H2786 June 1980Interim Deficiency Rept Re Centrifugal Charging Pump Operation Following Secondary Side Line Rupture Discussed in 800508 Telcon.Evaluation of Transient Described in Westinghouse 800508 Ltr Will Be Provided Pending Completion
ML19326D98118 July 1980Interim Deficiency Rept Re out-of-tolerance Conditions on Major Bolt & Minor Nut Diameters for Matls Supplied by Industrial Mechanics,Inc.Insp Program Established & Equipment on Order.Final Rept Expected by 801201
ML19327A28430 July 1980Deficiency Rept Re Potential Bolt head-pipe Clamp Interference Affecting Bergen-Paterson Pipe Support Strut Assemblies Containing Pacific Scientific Mechanical Shock Arrestors.Final Rept Will Be Submitted by 800930
ML19327A2991 August 1980Interim Deficiency Rept Re Adequacy of Application & Insp of Structural Steel Fireproofing Matls.Preliminary Review Indicates Deficiencies Are Probably Not Significant.Addl Evaluation Required.Final Rept Will Be Submitted by 800829
ML19327A30029 July 1980Interim Deficiency Rept Re Improper Preheat of Heavy Structural Members Prior to Welding.Requests Extension Until 801128 to Submit Final Rept,Due to Performance of Addl Test
ML19327A30131 July 1980Final Deficiency Rept Re out-of-tolerance Threads within NSSS Lateral Support Anchor Bolt Nuts.Reinspection & Test Program Completed.Withdraws Items as Significant Deficiency
ML19327A56014 July 1980Supplementary Part 21 Rept Re Hangers.Submits Revised List of Items Affected,Containing Corrections.Significant Revisions Include Hanger Mark FC02-R508/125(Q) Which Was Omitted from Wolf Creek Listing
ML19330A79720 June 1980Part 21 Rept Re Potential Interference in Full Function of Bergen-Paterson Strut Assembly W/Pacific Scientific Co Mechanical Shock Arrestor.Customers Will Be Notified of Affected Items & Recommended Solution
ML19330A82424 July 1980Final Deficiency Rept Re Generic Deficiencies in Corner & Lada,Inc Pipe Support Sway Struts.Onsite Insp &/Or Tests Will Assure That Assemblies Are Acceptable for Use.Corner & Lada Generic Rept Encl
ML19330B28930 June 1980Deficiency Rept Re Postulated Feedwater Line Piping Break. Excessive Peak Pressure Calculations Performed by Bechtel Considered Part of Normal Design Evolution.Does Not Consider Matter Reportable Per 10CFR50.55(e)
ML19331E27729 August 1980Final Deficiency Rept Re Adequacy of Application & Insp of Fireproofing Matls Applied to Structural Steel,Previously Reported on 800801.Defective Areas Noted in Reinsp Will Be Reworked to Assure Application Conformance
ML19331E37831 July 1980Final Deficiency Rept Re NSSS Lateral Support Anchor Bolt Nuts.Had Nonconformance Gone Undetected,No Significant Safety Problem Would Have Arisen.Item Withdrawn as Significant Deficiency
ML19338D68410 September 1980Final Deficiency Rept Re Potential Bolt head-pipe Clamp Interference Which Could Hinder Full Function of Bergen- Patterson Pipe Support Strut Assemblies.Bechtel Power Corp Advised That All Assemblies Corrected Prior to Shipment
ML19338F76815 September 1980Interim Deficiency Rept Re Centrifugal Charging Pump Operation Following Secondary Side High Energy Line Rupture.Design Changes Being Evaluated.Final Rept Will Be Provided in First Quarter 1981
ML19338G40929 August 1980Final Deficiency Rept Re Adequacy of Application & Insp of Albi-Duraspray Fire Proofing Mtls Applied to Structural Steel in safety-related Bldgs.Review of Reinsp Indicated Deficiencies Were Minor.Areas Reworked
ML19338G4137 October 1980Amended 800702 Deficiency Rept Re Pipe Support Strut W/ Mechanical Shock Arrestor.Supports Placed on Hold & Will Be Disposed of Per Nonconformance Control Procedures
ML19339C74514 November 1980Amended Deficiency Rept Re Bergen-Paterson Pipe Support Strut W/Mechanical Shock Arrestor Having Insufficient Clearances to Permit Specified Angular Movement.Vendor Determined Addl Delivered Assemblies Are Deficient
ML19340E4397 January 1981Final Deficiency Rept,Originally Submitted 800620,re Out of Tolerance Conditions on Major Bolt Diameters & Minor Nut Diameters Supplied by Industrial Mechanic,Inc.Analysis by A/E Indicates No Predicted Reduction in Design Capacity
ML19340E4692 January 1981Interim Deficiency Rept,Originally Reported on 801205,re Concrete Deficiences Discovered Near Surface of Reactor Bldg Dome.Further Evaluation Will Be Performed by Bechtel.Final Evaluation to Be Completed by 810401
ML19343A45930 June 1980Deficiency Rept Re Excessive Pressures in Feedwater Lines Following Postulated High Energy Line Break.Pressure Can Be Reduced by Relocating Feedwater Check Valves.Util No Longer Considers Matter Reportable Under 10CFR50.55e
ML19344A5631 August 1980Interim Deficiency Rept Re Application & Insp of Structural Steel Fireproofing.Final Rept Expected to Be Submitted by 800829
ML19344F37524 July 1980Final Deficiency Rept Re Loose Bushings in Pipe Support Sway Struts.Struts Found with Loose Bushings Will Be Replaced. Corner & Lada 800724 Rept Encl
ML19345C01428 November 1980Final Deficiency Rept Re Use of Improper Preheat of Heavy Structural Members Prior to Welding,Initially Reported on 800418.Physical Test Program Has Been Conducted.Welds Are Acceptable as Is
ML19345C32826 November 1980Final Deficiency Rept,Originally Submitted 801027,re Generic Design Interferences Between Bergen-Patterson Pipe Clamp Assemblies & Pacific Scientific Co Mating Snubber Assemblies.Clamps Will Be Modified or Replaced
ML19345G5841 April 1981Final Deficiency Rept Re Installation of Surface Mounted Plates.All Surface Mounted Plates Have Been Reinspected. Nonconforming Plates Will Be Reworked.All surface-mounted Plates Will Be in Conformance W/Specs & Drawings
ML19347B5827 October 1980Interim Deficiency Rept Re Bergen-Paterson Pipe Support Strut W/Mechanical Shock Arrestor.Bechtel Analyzed Two Pipe Supports.Two Supports Placed on Hold & Will Be Dispositioned According to Nonconformance Control Procedures
ML19347C27626 August 1980Final Deficiency Rept Re Nonconforming Threads on 3.5-inch Diameter Studs & Nuts for NSSS Steam Generator Lateral Supports.Encl Bechtel Rept Suppls Data Transmitted in 800731 Submittal