l UbmoN ELECTRIC COMPANY l 1901 GRATIOT STR ECE i ST. Louts. MissouR 4 October 7, 1980 l uAnu mo Aoo a... I a o = i<. . w.~ ..o.......

......... .v. co u. .. .... ou.. . .. . .

Mr. James G. Keppler U. S. Nuclear Regulatory Commission  !

] Region III  !

799 Roosevelt Road l j

Glen Ellyn, IL 60137 ULNRC- 393 I

Dear Mr. Keppler:

AMENDED 10CFR50.55(e) REPORT BERGEN-PATERSON PIPE SUPPORT STRUT WITH MECHANICAL SHOCK ARRESTOR CALLAWAY PLANT UNIT 1 Ref: ULNRC-386, 9/10/80

On July 2, 1980 we provided NRC Region III verbal noti-

.fication of a 10CFR50.55(e) report regarding a potential bolt head-pipe clamp interference which could hinder the full function of Bergen-Paterson (B-P) pipe support strut assemblies containing Pacific Scientific mechanical shock arrestors. In the final report transmitted with the referenced letter we indicated that information Bechtel Power Corporation had received from B-P advised that all assemblies for Callaway Unit I were corrected prior to shipnent.

We have now determined that two pipe support strut assemblies delivered to callaway have not been corrected. These items are identified by hanger mark numbers 2-EM01-R030/112 and 2-EM01-C043/112.

Bechtel Power Corporation has analyzed these two supports and has determined that no condition adverse to safety would result if the existing interference were not corrected. ,

These two supports, one installed and one in the warehouse, have been placed on hold anc will be appropriately dispositioned according to existing non-conformance control procedures.

Very truly yours,

.ro nf

\. oryan 4 Y\,

WSS/RPW/sla Enclosure cc: H. M. Wescott, Region TII B. H. Grier, Region ' ,

Victor Stello, Jr., Director Of fice I&E L W. A. Hansen, NRC Resident Inspector K. V. Seyfrit, Region IV g/f Mo. Public Service Commission 8010150 33 S

- -