UNION ELECTRIC: COM PANY 1901 GR ATIOT STREET ST. Loute, Missount May 13, 1980

    • C,*ll!'"l."'

so ~ m.av.~

Mr. James G.

Keppler U.

S. Nuclear Regulatory Commission Region III 799 Roosevelt Road ULNRC-353 Glen Ellyn, IL 60137

Dear Mr. Keppler:

SUBMITTAL DATE EXTENSION 10CFR50. 55 (e) REPORT IMPROPER PREHEAT OF HEAVY STRUCTURAL MEMBERS PRIOR TO WELDING CALLAWAY PLANT UNIT 1 On April 18, 1980 we provided the NRC Resident Inspector at Callaway verbal notification of a potential 50.55(e) report regarding use of improper preheat when welding pipe supports to heavy structural steel members.

The above notification was made after discrepancies in weld control records were identified by the Resident Inspector.

A complete evaluation of this matter by Bechtel Power Corporation is underway and we anticipate that we will be able to submit a final report by July 31, 1980.

Very truly yours, Y

' rb

/!

John K. Bryan RPW/sla cc:

H. Wescott, Region III B. H. Grier, Region I Victor Stello, Jr. Director Office of I&E&#

K. V. Seyfrit, Region IV W. A.

Hansen, NRC Resident Inspector, Callaway Plant Missouri Public Service Commission 0

F e

8085s19WNg