ML19326D981

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re out-of-tolerance Conditions on Major Bolt & Minor Nut Diameters for Matls Supplied by Industrial Mechanics,Inc.Insp Program Established & Equipment on Order.Final Rept Expected by 801201
ML19326D981
Person / Time
Site: Callaway  Ameren icon.png
Issue date: 07/18/1980
From: Bryan J
UNION ELECTRIC CO.
To:
References
ULNRC-366, NUDOCS 8007250336
Download: ML19326D981 (1)


Text

70 '/ ft 3 PK-,

UNION EtccTaic COMPANY 100 6 G R ATIO T STR CF.T ST, Louis. M tsso gni so~~x.....~ Ju1y 18, 1980 " 7".*,^ff,"ff *'

,,u.......- .r. to u. .. u . . . o v . , . . . . .

Mr. James G. Keppler, Director Region III Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 799 Flosevelt Road Glen Ellyn, Illinois 60137 ULNRC-366

Dear Mr. Keppler:

SUBMITTAL DATE ENTENSION INTERIM REPORT - ANCHOR BOLTS AND NUTS CALLAWAY PLANT UNITS 1 AND 2 On Friday, June 20, 1980, we provided Mr. H. M. Wescott verbal notification of a 10CFR50.55(e) report regarding out of tolerance conditions on major bolt diameters and minor nut diameters for material supplied by Industrial Mechanics, Inc.

An inspection program has been established and equipment is on order to complete the inspection.

Based on the time required for equipment deliveries, field inspection and evaluation of the data from the field inspection, we anticipate that the date of issue of our final report will be December 1, 1980.

Very,truly yours, f /

/

> 'jg/ g l

(! .

(VV \,h John K. 'ryan b ' O M \ 0 \'

j

.l i

J WHZ/sla 1

cc: H. M. Wescott, Reaion III  !

B. H. Grier, Region I l A ctor Stello Jr., Director Office of I&E i K. V. Seyfrit, Region IV l W. A. Hansen, NRC Resident Inspector, Callaway Plant l Missouri Publi' Service Commission go19 ts o 0 7 2 30:3yg.

Sio

..