ML19323G152

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Pipe Support Sway Struts W/Loose Bushings. During Seismic Event,Piping Could Be Overstressed.Struts Have Been Reworked to Correct Deficiency
ML19323G152
Person / Time
Site: Wolf Creek, Callaway, Sterling  Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 05/19/1980
From: Meyers B
BECHTEL GROUP, INC.
To:
References
REF-PT21-80-225-000 NUDOCS 8005300461
Download: ML19323G152 (5)


Text

.

ATTACHED IS A PART 21 REPORT FROM IE f%IL UNIT - ROOM 359Eh!

PART21IDMIFICATIONNO, 8b-aar %

COMPANY t#E 6eclCal b'^

DATE OF LETTER 6'/'?/f o DOCKET NO, So-W, n 4fa

-Ng.

^'

DATEDISTRIBUTED r/.n/f'd ORIGINAL REPORT 2 SUPPLB EITARY Z DISTRIBUTION:

REACTOR (R)[

FUELCYCLE&

SAFEGUARDS (S)

~

~

f%TERIALS(M)

NRR/ DOR, DIRECTOR AD/FFMSI-AD/SG-IE NRR/DPM DIRECTOR fNSS/FCMS AD/RDI AD/RDI ( 2 )

REGIONS REGIONS AD/RCI IEFILES NRR/ DOR, DIRECT 0'R-REGIONS PDR NMSS/SG SS-881 IE FIES (2)

LPDR PDR CEfffPAL FILES CENTRAL FILES-SS-396 LPDR CBffRALFILES(CHRON)

FILES (CHRON)

TEPA PDR IE FILES (2)

LPDR CENTRAL FIES 016

" TERA

  • L0EB/MPA MB 5715 CENTPAL FILES (CHRON)

LOEBhPA MB 57h AE0D - MBB-7602 CBiTPAL FILES - SS-396 AEOD MiBB-7602 LDEBhPA MiB 57A5 I AE0D ffGB-7602 ACTION:

PRELIMINARY EVUALATION OF THE ATTACHED REPORT INDICATES LEA FOLLOW-UP AS SHOWN BELOW:

JEE EZ ElZ DIE Z SG

"*" 5

  • 5'5'8

,, o,a o o gj

k Bechtel Power Corporation Engineers-Constructors 15740 Shady Grove Road Gaithersburg, Maryland 20760

/

301-258 3000 Nby 19, 1980 Q,210 00 6 Mr. Boyce H. Grier Director, Region 1 Office of Inspection and Enforcement U. S. Nucicar Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

SNUPPS Project, Bechtel Job No. 10466 Report of Defective Components Under 10CFR Part 21 In accordance with the requirements of 10CFR Part 21, this is to confirm reporting of a 10CFR Part 21 deficiency, by telephone on 5/14/80, by Bechtel personnel to Mr. L. Narrows, Office of Inspection and Enforcement, R'egion I, U. S. Nuclear Regulatory Commission. The report concerns pipe support sway struts with loose bushings furnished to the Callaway Unit 1 and Wolf Creek Jobsites by Corner & Lada Co., Inc., Cranston, Rhode Island.

The same deficiency was reported on 5/12/80, to Mr. R. McGaughy, Office of Inspection and Enforcement, Region I, U. S. Nuclear Regulatory Com=ission, by SNUPPS as a generic Significant Reportable Deficiency per 10CFR50.55(e).

This report is being submitted by Bechtel Power Corporation, per 10CFR Part 21, since Bechtel's evaluation indicates that it is reportable to the NRC per 10CFR Part 21 requirements. Corner & Lada was advised, verbally and in writing, by Bechtel to report the deficiency to the NRC. However, Corner &

Lada has advised Bechtel, by a TWX dated 5/14/80, that they are not required to file a report under 10CFR Part 21 since they have no prior knowledge of any struts manufactured with loose bushings (bearings) and have found no deficiencies in their design criteria and manufacb; ring processes which would create the locse bushing (bearing) condition.

Therefore, Bechtel is filing this report, is required by 10CFR Part 21 requirements.

Bechtel Power Corporation Mr. Boyce H. Grier May 19, 1980 j

, Following is specific information required by 10CFR Part 21:

1.

INDIVIDUAL REPORTING Bernard L. Meyers SNUPPS Project Manager Bechtel Power Corporation 15740 Shady Grove Road Gaithersburg, Maryland 20760 2.

FACILITY AND COMPONENT IDENTIFICATION Callaway Unit 1 (Union Electric Company) Fulton, Missouri and Wolf Creek (Kansas Gas and Electric Company) Burlington, Kansas.

Approximately 1300 of Size 2 and 3 sway struts delivered to the jobsites prior to 11/28/79.

3.

SUPPLYING FIRM Corner & Lada Co., Inc.

1341 Eltwood Avenue Cranston, Rhode Island 02910 4.

NATURE OF DEFECT Loose bushings in size 2 and 3 sway struts at the clamp end. As a result of the loose bushings, the sway strut paddle can become completely disengaged from the bushing, causing a 3/8" gap between the innersurface of the paddle and the pin. Existence of the gap, during a seismic event, cay result in piping and/or piping welds being overstressed causing a possible safety hazard.

5.

DATE OF NOTIFICATION OF THE DEFECT Bechtel Power Corporation was notified verbally, on 5/8/80, by Corner &

Lada that the tests, conducted by them as requested by Bechtel, to deternine if the paddle with loose bushings on the clamp end for Size 2 and 3 sway struts can become completely disengaged indicated that this possibility exists.

Bechtel Power Corporation Mr. Boyce H. Grier Pby 19, 1980 On 5/12/80, Bechtel concluded that, based on Corner & Lada's test results and since sway struts with loose bushings had been shipped to the jobsites and accepted for use, this defect was reportable to the NRC per 10CFR Part 21.

6.

OTHER COMPONENTS WITH IDENTICAL DEFECT None known to Bechtel at this time.

Corner & Lada should be contacted, by the NRC, for identification of other facilities to which similar components may have been supplied.

7.

CORRECTIVE ACTION All Size 2 and 3 sway struts, delivered prior to 11/28/79 had been inspected and any bushings found loose had been reworked (" staked") by Corner & Lada personnel at the Callaway Jobsite between 1/21/80 and 2/15/80.

Similarly, all Size 2 and 3 sway struts, delivered prior to 11/28/79, had been inspected and any bushings found loose had been reworked (" staked") by Corner & Lada personnel at the Wolf Creek Jobsite between 11/30/79 and 2/20/80.

8.

NOTIFICATION TO OTHER LICENSEES The SNUPPS organization, Union Electric Conpany and Kansas Gas and Electric Company have been notified.

Sincerely,

/

f<f--

3 Bernard L. Meyers SNUPPS Project Manager DCK/dkh cc:

See attached Distribution List l

l

DISTRIBUTION LIST cc:

Mr. Victor Stello (3 copics)

Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Coc=ission Washington, D. C.

20555 Mr. N. A. Petrick (1 copy)

Executive Director, SNUPPS 5 Choke Cherry Road Rockville, Maryland 20850 Mr. S. J. Seiken (1 copy)

QA Manager, SNUPPS 5 Choke Cherry Road Rockville, Maryland 20850 Mr. E. W. Creel (1 copy)

QA Manager Kansas Gas and Electric Company P. O. Box 208 Wichita, Kansas 67201 Mr. F. D. Field (1 copy)

QA Manager Union Electric Company P. O. Box 149 St. Louis, Edssouri 63166 Px. E. Corner (1 copy)

President Corner & Lada Co., Inc.

1341 Elt ood Avenue Cranston, Rhode Island 02910

_