ML19318A961

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Surface Mounted Plates. Reinspection of Surface Mounted Plates Underway.Final Rept Will Be Issued on 800908
ML19318A961
Person / Time
Site: Callaway  Ameren icon.png
Issue date: 06/16/1980
From: Bryan J
UNION ELECTRIC CO.
To:
References
ULNRC-360, NUDOCS 8006240441
Download: ML19318A961 (1)


Text

. _.__

UNION ELECTmc COMPANY tool omATsoT sTmetET ST. Louis, Missoums June 16, 1980

" " T ff f "ll

so ~n...

Mr. James G. Keppler, Director Region III Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road ULNRC-36 )

Glen Ellyn, Illinois 60137 Dear Mr. Keppler SUBMITTAL DATE EXTENSION INTERIM REPORT - SURFACE MOUNTED PLATES CALLAWAY PLANT UNITS 1 AND 2 On May 21, 1980, we provided Mr. W. A.

Hansen verbal notification of a potential significant deficiency regarding the installation of surface mounted plates.

Since that date a reinspection of all surface mounted plates has been underway.

Since our reinspection is not complete, and to insure that all data has been reviewed and evaluated properly, we anticipate that the date of issue of our final report will be September 8, 1980.

Very truly yours, 0

/

A W 64\\

Jo n K. Bryag WHZ/sla cc:

H. Wescott, Region III B.

H. Grier, Region I Victor Stello Tr., Director Office of I&E"'#

K. V.

Seyfrit, Region IV W. A. Hansen, NRC Resident Inspector, Callaway Plant Missouri Public Service Commission f00l s

/O 8 006340N S