ML17229A887

From kanterella
Revision as of 15:42, 7 July 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Part 21 Rept Re Potential Defect in Swagelok Stainless Steel Front Ferrule,Part Number SS-503-1 Which Was Machined with Improper Length.C/A Includes Insp Equipment That Will 100% Identify Short Length
ML17229A887
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 10/19/1998
From: MALEC K J
External (Affiliation Not Assigned)
To:
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-98 NUDOCS 9810280110
Download: ML17229A887 (6)


Text

CATEGORY 1.REGULATORY XNFORMATION DISTRIBUTXON sYSTEM (RIDS)ACCESSION NBR:9810280110 DOC.DATE: 98/10/19 NOTARIZED:

NO FACIL:50-335 St.Lucie Plant, Unit 1, Florida Power 6 Light Co.50-389 St.Lucie Plant, Unit 2, Florida Power 6 Light Co." AUTH.NAME AUTHOR AFFILIATION

~MALEC,K.J.

RECIP.NAME DOCKET¹05000335 ,05000389

SUBJECT:

Part 21 rept re potential defect in Swagelok stainless steel front ferrule, part number SS-503-1 which was machined with improper length.C/A includes insp ecpxipment that will 100't identify short length.DISTRIBUTION CODE: IE19T COPIES RECEIVED:LTR ENCL SIZE: TITLE: Part-21 Rept (50 DKT)E NOTES: RECIPIENT ID CODE/NAME PD2-3 PD INTERNAL: E CENT R 01 ECB B RES/DET/EIB RGN2 RGN4 COPIES LTTR ENCL 1 1 1 1 1 1 1 1 1 1 1 1 RECIPIENT ID CODE/NAME GLEAVES,W NRR/DRPM/PECB PDR WARD, M.RGN1 RGN3 COPIES LTTR ENCL 1 1 1 1 1 1 1 1 1 1 EXTERNAL: INPO RECORD CTR NRC PDR 1 1 1 1 NOAC SILVER,E NUDOCS FULL TXT 1 1 1 1 D THls DOCUMENT HAS BEEN SCANNED NOTE TO ALIi"RZDS" RECIPIENTS:

PLEASE HELP'US TO REDUCE WASTE.TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPZES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)ON EXTENSION 415-2083 FULL TEXT CONVERSXON REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR 15 ENCL 15 Q~g+Qho~SWAGELOK COMPANY 29500 Solon Road, Solon, Ohio 44139-3492 U.S.A.October 19,1998 Document Control Desk Office of Reactor Regulation Nuclear Regulatory Commission Washington, DC 20555

Subject:

Defects Potentially Reportable under 10CFR part 21 We are writing about a potential defect in a Swagelok stainless steel front ferrule, part number SS-503-1.The part is marked with the heat code IVD on it.The front ferrule is shipped as a component in a Swagelok tube fitting, or sold as a replacement part.The list of utilities to whom we have sold these parts is enclosed.We are notifying each licensee concurrently with this notice.The potential problem is that the ferrule was machined with an improper length, resulting in the 45 degree chamfer at the trailing edge to be missing.Laboratory testing of this part has shown that it will leak immediately on gas service, and will hold to about 2.5 times working pressure of the tubing during a hydraulic pressure test.The improper length was caused by insufficient feedout of the bar on a multiple spindle machine.Our analysis shows that this would be a first part error and that only a small number of ferrules are affected.Our automated assembly equipment is set to reject this condition, and of the parts that were not sent through automated assembly, about one per cent of the lot is included.Corrective action includes inspection equipment that will 100 per cent identify this short length.A sales drawing that shows a proper ferrule and one with the short length is enclosed.If there are any questions, please do not hesitate to contact us.98i0280iiO 98iOi9'oo ADQCt4', OSOaOSSS S" PDR W<I i Sincerely en an J.Malec Vice President and General Manager Telephone:

440-2484600 Fax: 440%9-5970 SS-503-1 (IVD)Westinghouse Electric Corp.P.O.¹MB-33772 Product ID¹D18GV0197S Repair Replacement Service 43 pcs.SS-500-6-2BT Florida Power 8 Light Product ID¹R18FN0151 St.Lucie Nuclear Plant.PO¹00032836 10 pcs.SS-500-SET Mitsubishi Heavy Industries Ltd.Product ID¹R17IE0516 Kobe Shipyard 8 Machinery¹2303944-KG-865564 38 pcs.SS-503-1 S;vagetck Gccy Swage!ck Front.rn:te=riagetok ac.'c 07 Swageick tct PART NO.503-1 ACCEPTABLE 10x SIZE FULL SIZE NOT ACCEPTABLE 10x SIZE FULL SIZE CUSTOMER DRAWING SWAGELOK COMPANY-DRAWING NOT TO SCALE.-DIHENSIONS ARE INCHES OVER IH ILL IHETERS).-DRAWING IS SUBJECT TO CHANGE WI THOUT NOT I CE.mum eT APPROVED II DATE l~V/~~TITLE fART 503-1 SS-503-1 (IVD)Westinghouse Electric Corporation PO¹MB-50337-D 16 pcs.SS-1210-6-5BT ID D18HE0125B Repair Replacement Service 2000 Cheswick Ave Cheswick PA 15024