oj.

83-79/-600' f

The Garvest Corporellon 9851 Sepulveda Boulevard P.C. Box 92248 Los Angeles California 90009 Cable: Garrettair Los Ange4a Refer To: 25:2003:0298:050983 May 9,'1983 United States Nuclear Regulatory Commission Director, Office of Inspection and Enforcement 1717 "H" Street N.W.

Washington, D.C.

20555 Re: Product Deviation Notification

Dear Sir:

The undersigned makes the following product deviation notification to the Nuclear Regulatory Commission with respect to a functional deviation in the below described component installed in the St. Lucie II nuclear power reactor.

This notification is being made pursuant to 10 CFR 21.21(b).

Garrett Pneumatic Systems Division, a division cf the Garrett Corporation, has identified an apparent short-term rpliability problem with the position indica-ting mechanism in a solenoid valve used to ccatrol PORv 3750010. At this time, the deviation is known to have occurred in only the one unit.

Recently, Garrett became aware that the system lights in the St. Lucie II Power Plant which indicate PORV 3750010 valve position were not functioni Prior to that time the advisory lights had been functioning properly. On Ma 7, while troubleshooting the system, a magnet in the position indicating mechanism was replaced. Subsequently the valve position indications have functioned properly.

Currently, a detailed investigation is in process to determine the cause of the deviation and whether it may occur in other units or if this is an isolated Case.

A similar magnet actuated switch mechanism is incorporated in PORV 3750014 and 80VV 3750038 installed in the reactors identified on the attached list.

These valves are manufactured under N-Stamp #2516 for Combustion Engineering and Westinghouse.

They are used on the safety class 1 and 2 systems of the reactors identified in the attached list.

Combustion Engineering and Westinghouse have been advised of this event and Garrett will continuely advise them as to progress and corrective action.

Y'Y

/

One of The Signal 8306300202 830509 companies PDR ADOCK 05000389 S

PM

_. f:.

t.

w t

- Director 25:2003:0298:050983-U.S. Nuclear Regulatory Commission May 9,.1983 Page 2 Garrett will further advise the commission regarding the results of the investigation and any: follow-up corrective action to be taken.

.Very truly_yours,.

(,

f Vern M. Johnson Director, Produc Integrity VRT:jkr Enclosure

- cc:

U.S. Nuclear Regulatory Commission Arlington, Texas l.

i-r i

~_

Valve Part Number Customer l Location 3750010 S/N 101 Combustion-St. Lucie II Power Plant S/N 102 Engineering 3750038 S/N 101 Combustion St. Lucie II Power Plant thru Engineering S/N 108 3750014 S/N 101 Westinghouse Callaway Nuclear Power Plant S/N 102 Portland, Missouri S/N 103 Westinghouse Wolf Creek Nuclear Power Plant S/N 105 Fulton, Missouri 3750014 S/N 119 Westinghouse Beaver Valley Nuclear Power Plant S/N 121 Shippingp0rt, PA S/N 122 3750014 S/N 106 Westinghouse Southwest Fabricating S/N 108 Houston, Texas thru S/N 112 S/N 116 S/N 117 S/N 118 4

l i

l 3750014 S/N 104 Westinghouse Phillipines Nuclear Power Plant l

S/N 107 Phillipines 3750014 S/N 113 Westinghouse Taiwan Nuclear Power Plant S/N 114 Taiwan S/N 115 g

l l

l 1

-. _ _, _ _