{{#Wiki_filter:Mr. Bruce D. Kenyon                                                      January 13, 1997
  ,              President - Nuclear Group Northeast Utilities Service Group c/o Mr. Terry L. Harpster i              Director - Nuclear Licensing Services P.O. Box 388 Waterford, CT 06385
 
==Dear Mr. Kenyon:==
 
The NRC's Order to Northeast Nuclear Energy Company (NNECO) dated October 24, 1996, required NNECO to submit, within 60 days from the date of the Order, a comprehensive plan for reviewing and dispositioning safety issues raised by NNECO employees. NNECO's December 23, 1996, letter recuested an extension of 30 days for the submittal of the comprehensive plan. NhECO's January 22, 1997, letter extended that request until February 4, 1997. This is based on your indication that additional time was needed to address recommendations from an employee concerns task force so that work could be completed on the comprehensive plan in a deliberate manner.
The Order states that the Director Office of Nuclear Reactor Regulation, may, in writing, relax or rescind the Order u)on demonstration by the licensee of gcod cause. I find your request reasona)le and, therefore, grant an extension until February 4,1997, for submittal of a comprehensive plan. This action does not relax any of the other provisions of the Order.
Sincerely, Original signed by:
Frank J. Miraglia, Jr., Acting Director Office of Nuclear Reactor Regulation Docket Nos. 50-245, 50-336, and 50-423 cc: See next page DISTRIBUTION:
                ' Docket fileal PUBLIC SP0 Plant WTravers PMcKee LBerry HPastis OGC                                                                                                                                      1 ACRS WLanning, RI Qd L/
                                                                                                                                                        ,  p n.iO O 38 DOCUMENT NAME: G:\PASTIS\KENYON.LTR                                                      *See previous concurrence Ta receive e copy of this document indicate in the box: "C" - Copy without ettschment/ enclosure *E' = Copy with attachment / enclosure *N* = No copy 0FFICE        SPO-L:LA              l          SPO-L:LA          l          SPO-L:DD          l        SP0                l        OGC          l NAME          HPastis                          LBerry                      PMcKee                      WTravers                    CMarco DATE          01/0                            01/07/97*                    01/07/97*                  01/07/97*                    01/08/977
. mmesammum                            summe =====_.                uneum    = = = = = = =      -ammessammenes mammemeasummmesma menen 0FFICE        N            )
NAME        MMirW9Yia DATE          01/13/97*                        01/ /97                      01/ /97                    01/ /97                      01/ /97 0FFICIAL RECORD COPY 9702040191 970113 PDR        ADOCK 05000245 p                                PDR
 
e regg
  ,, tj        1                          UNITED STATES y          }            NUCLEAR RE2ULATCRY COMMISSIEN 3
* WA8HINGTON, D.C. 30666-0001
    \****+,$
January 13, 1997 Mr. Bruce D. Kenyon President - Nuclear Group Northeast Utilities Service Group c/o Mr. Terry L. Harpster Director - Nuclear Licensing Services P.O. Box 388 Waterford, CT 06385
 
==Dear Mr. Kenyon:==
 
The NRC's Order to Northeast Nuclear Energy Company (NNECO) dated October 24, 1996, required NNECO to submit, within 60 days from the date of the Order, a comprehensive plan for reviewing and dispositioning safety issues raised by NNECO employees. NNECO's December 23. 1996, letter recuested an extension of 30 days for the submittal of the comprehensive plan. bNECO's January 22, 1997, letter extended that request until February 4, 1997. This is based on your indication that additional time was needed to address recommendations from an employee concerns task force so that work could be completed on the comprehensive plan in a deliberate manner.
The Order states that the Director Office of Nuclear Reactor Regulation, may.
in writing, relax or rescind the Order u)on demonstration by the licensee of good cause. I find your request reasonaale and, therefore, grant an extension until February 4. 1997, for submittal of a comprehensive plan. This action does not relax any of the other provisions of the Order.
Sincerely, Af            . h.
FrankJ.@iragl'      r..AbingDirector Office of Nuclear Reactor Regulation Docket Nos. 50-245, 50-336, and 50-423 cc: See next page
 
i Northeast Utilities Service Company    Millstone Nuclear Power Station
,,                                        Units 1, 2, and 3 cc:                                                                                    l 1
Lillian M. Cuoco, Esquire                      Mr. Wayne D. Lanning Senior Nuclear Counsel                        Deputy Director of Inspections Northeast Utilities Service Company            Special Projects Office                ;
P.O. Box 270                                  475 Allendale Road                      i Hartford, CT 06141-0270                        King of Prussia, PA 19406-1415          l Mr. Kevin T. A. McCarthy, Director            Mr. F. C. Rothen Monitoring and Radiation Division              Vice President - Work Services Department of Environmental                    Northeast Utilities Service Company    4 Protection                                  P.O. Box 128 79 Elm Street                                  Waterford, CT 06385 Hartford, CT 06106-5127 Charles Brinkman, Manager Mr. Allan Johanson, Assistant                  Washington Nuclear Operations Director                                    ABB Combustion Engineering Office of Policy and Management                12300 Twinbrook Pkwy, Suite 330 Policy Development and Planning                Rockville, MD 20852 Division 450 Capitol Avenue - MS 52ERN                  Mr. D. M. Goebel P.O. Box 341441                                Vice President - Nuclear Oversight l
{
Hartford, CT 06134-1441                        Northeast Utilities Service Company P. O. Box 128 Regional Administrator, Region I              Waterford, CT 06385 U.S. Nuclear Regulatory Commission 475 Allendale Road                            Mr. J. P. Cowan King of Prussia, PA 19406                      Millstone Unit No. 3 Nuclear Recovery Officer First Selectmen                                Northeast Utilities Service Company Town of Waterford                              P. O. Box 128 Hall of Records                                Waterford, CT 06385 200 Boston Post Road Waterford, CT 06385                            Mr. M. L. Bowling, Jr.
Millstone Unit No. 2 Nuclear Mr. P. M. Richardson                            Recovery Officer Nuclear Unit Director                          Northeast Utilities Service Company Millstone Nuclear Power Station,              P. O. Box 128 Unit No. 2                                  Waterford, CT 06385 Northeast Utilities Service Company P. O. Box 128 Waterford, CT 06385
 
i
  ,o Northeast Utilities Service Company              Millstone Nuclear Power Station Units 1, 2, and 3
: j. ,,                                                                                                          i cc:
a Mr. M. H. Brothers                                        Mr. P. D. Hinnenkamp i              Nuclear Unit Director                                    Director, Unit Operations 4
Millstone Nuclear Power Station,                          Northeast Utilities Service Company 4                Unit No. 3                                              P. O. Box 128
.              Northeast Nuclear Energy Company                          Waterford, CT 06385 P. O. Box 128 Waterford, CT 06385                                      Mr. J. P. McElwain Millstone Unit No. I Nuclear Burlington Electric Department                                  Recovery Officer
;              c/o Robert E. Fletcher, Esq.                              Northeast Utilities Service Company 271 South Union Street                                    P. O. Box 128 Burlington, VT 05402                                      Waterford, CT 06385                    i Mr. M. R. Scully, Executive Director                      Mr. T. C. Feigenbaum
;              Connecticut Municipal Electric                            Executive Vice President and i'
Energy Cooperative                                            Chief Nuclear Officer          ;
30 Stott Avenue                                          Northeast Utilities Service Company  1 Norwich, CT 06360                                          P. O. Box 128
:                                                                        Waterford, CT 06385 i              Mr. William D. Meinert l              Nuclear Engineer                                          Deborah Katz, President i              Massachusetts Municipal Wholesale                        Citizens Awareness Network 3
Electric Company                                        P.O. Box 83                            l P.O. Box 426                                              Shelburne Falls, MA 03170 Ludlow, MA 01056 i                                                                      Senior Resident Inspector            i 2
Ernest C. Hadley, Esquire                                Millstone Nuclear Power Station
:              1040 B Main Street                                        c/o U.S. Nuclear Reguatory Commission
!              P.O. Box 549                                              P.O. Box 513                          .
j              West Wareham, MA 02576                                    Niantic, CT 06357                    l 4
Joseph R. Egan, Esq.
Egan & Associates, P.C.
;              2300 N Street, NW j              Washington, D.C. 20037
)              Mr. J. K. Thayer
!            Recovery Officer, Nuclear Engineering and Support Northeast Utilities Service Company P. O. Box 128 Waterfod, CT 06385 l}}

Revision as of 21:33, 22 July 2020

Responds to Licensee 970122 Ltr Requesting Extension of Time to Respond to NRC 961024 Order,Comprehensive Plan for Reviewing & Dispositioning Safety Issues.Extension Granted Until 970204
ML20134C956
Person / Time
Site: Millstone  Dominion icon.png
Issue date: 01/13/1997
From: Miraglia F
NRC (Affiliation Not Assigned)
To: Kenyon B
NORTHEAST UTILITIES SERVICE CO.
References
NUDOCS 9702040191
Download: ML20134C956 (4)


Text

Mr. Bruce D. Kenyon January 13, 1997

, President - Nuclear Group Northeast Utilities Service Group c/o Mr. Terry L. Harpster i Director - Nuclear Licensing Services P.O. Box 388 Waterford, CT 06385

Dear Mr. Kenyon:

The NRC's Order to Northeast Nuclear Energy Company (NNECO) dated October 24, 1996, required NNECO to submit, within 60 days from the date of the Order, a comprehensive plan for reviewing and dispositioning safety issues raised by NNECO employees. NNECO's December 23, 1996, letter recuested an extension of 30 days for the submittal of the comprehensive plan. NhECO's January 22, 1997, letter extended that request until February 4, 1997. This is based on your indication that additional time was needed to address recommendations from an employee concerns task force so that work could be completed on the comprehensive plan in a deliberate manner.

The Order states that the Director Office of Nuclear Reactor Regulation, may, in writing, relax or rescind the Order u)on demonstration by the licensee of gcod cause. I find your request reasona)le and, therefore, grant an extension until February 4,1997, for submittal of a comprehensive plan. This action does not relax any of the other provisions of the Order.

Sincerely, Original signed by:

Frank J. Miraglia, Jr., Acting Director Office of Nuclear Reactor Regulation Docket Nos. 50-245, 50-336, and 50-423 cc: See next page DISTRIBUTION:

' Docket fileal PUBLIC SP0 Plant WTravers PMcKee LBerry HPastis OGC 1 ACRS WLanning, RI Qd L/

, p n.iO O 38 DOCUMENT NAME: G:\PASTIS\KENYON.LTR *See previous concurrence Ta receive e copy of this document indicate in the box: "C" - Copy without ettschment/ enclosure *E' = Copy with attachment / enclosure *N* = No copy 0FFICE SPO-L:LA l SPO-L:LA l SPO-L:DD l SP0 l OGC l NAME HPastis LBerry PMcKee WTravers CMarco DATE 01/0 01/07/97* 01/07/97* 01/07/97* 01/08/977

. mmesammum summe =====_. uneum = = = = = = = -ammessammenes mammemeasummmesma menen 0FFICE N )

NAME MMirW9Yia DATE 01/13/97* 01/ /97 01/ /97 01/ /97 01/ /97 0FFICIAL RECORD COPY 9702040191 970113 PDR ADOCK 05000245 p PDR

e regg

,, tj 1 UNITED STATES y } NUCLEAR RE2ULATCRY COMMISSIEN 3

  • WA8HINGTON, D.C. 30666-0001

\****+,$

January 13, 1997 Mr. Bruce D. Kenyon President - Nuclear Group Northeast Utilities Service Group c/o Mr. Terry L. Harpster Director - Nuclear Licensing Services P.O. Box 388 Waterford, CT 06385

Dear Mr. Kenyon:

The NRC's Order to Northeast Nuclear Energy Company (NNECO) dated October 24, 1996, required NNECO to submit, within 60 days from the date of the Order, a comprehensive plan for reviewing and dispositioning safety issues raised by NNECO employees. NNECO's December 23. 1996, letter recuested an extension of 30 days for the submittal of the comprehensive plan. bNECO's January 22, 1997, letter extended that request until February 4, 1997. This is based on your indication that additional time was needed to address recommendations from an employee concerns task force so that work could be completed on the comprehensive plan in a deliberate manner.

The Order states that the Director Office of Nuclear Reactor Regulation, may.

in writing, relax or rescind the Order u)on demonstration by the licensee of good cause. I find your request reasonaale and, therefore, grant an extension until February 4. 1997, for submittal of a comprehensive plan. This action does not relax any of the other provisions of the Order.

Sincerely, Af . h.

FrankJ.@iragl' r..AbingDirector Office of Nuclear Reactor Regulation Docket Nos. 50-245, 50-336, and 50-423 cc: See next page

i Northeast Utilities Service Company Millstone Nuclear Power Station

,, Units 1, 2, and 3 cc: l 1

Lillian M. Cuoco, Esquire Mr. Wayne D. Lanning Senior Nuclear Counsel Deputy Director of Inspections Northeast Utilities Service Company Special Projects Office  ;

P.O. Box 270 475 Allendale Road i Hartford, CT 06141-0270 King of Prussia, PA 19406-1415 l Mr. Kevin T. A. McCarthy, Director Mr. F. C. Rothen Monitoring and Radiation Division Vice President - Work Services Department of Environmental Northeast Utilities Service Company 4 Protection P.O. Box 128 79 Elm Street Waterford, CT 06385 Hartford, CT 06106-5127 Charles Brinkman, Manager Mr. Allan Johanson, Assistant Washington Nuclear Operations Director ABB Combustion Engineering Office of Policy and Management 12300 Twinbrook Pkwy, Suite 330 Policy Development and Planning Rockville, MD 20852 Division 450 Capitol Avenue - MS 52ERN Mr. D. M. Goebel P.O. Box 341441 Vice President - Nuclear Oversight l

{

Hartford, CT 06134-1441 Northeast Utilities Service Company P. O. Box 128 Regional Administrator, Region I Waterford, CT 06385 U.S. Nuclear Regulatory Commission 475 Allendale Road Mr. J. P. Cowan King of Prussia, PA 19406 Millstone Unit No. 3 Nuclear Recovery Officer First Selectmen Northeast Utilities Service Company Town of Waterford P. O. Box 128 Hall of Records Waterford, CT 06385 200 Boston Post Road Waterford, CT 06385 Mr. M. L. Bowling, Jr.

Millstone Unit No. 2 Nuclear Mr. P. M. Richardson Recovery Officer Nuclear Unit Director Northeast Utilities Service Company Millstone Nuclear Power Station, P. O. Box 128 Unit No. 2 Waterford, CT 06385 Northeast Utilities Service Company P. O. Box 128 Waterford, CT 06385

i

,o Northeast Utilities Service Company Millstone Nuclear Power Station Units 1, 2, and 3

j. ,, i cc:

a Mr. M. H. Brothers Mr. P. D. Hinnenkamp i Nuclear Unit Director Director, Unit Operations 4

Millstone Nuclear Power Station, Northeast Utilities Service Company 4 Unit No. 3 P. O. Box 128

. Northeast Nuclear Energy Company Waterford, CT 06385 P. O. Box 128 Waterford, CT 06385 Mr. J. P. McElwain Millstone Unit No. I Nuclear Burlington Electric Department Recovery Officer

c/o Robert E. Fletcher, Esq. Northeast Utilities Service Company 271 South Union Street P. O. Box 128 Burlington, VT 05402 Waterford, CT 06385 i Mr. M. R. Scully, Executive Director Mr. T. C. Feigenbaum
Connecticut Municipal Electric Executive Vice President and i'

Energy Cooperative Chief Nuclear Officer  ;

30 Stott Avenue Northeast Utilities Service Company 1 Norwich, CT 06360 P. O. Box 128

Waterford, CT 06385 i Mr. William D. Meinert l Nuclear Engineer Deborah Katz, President i Massachusetts Municipal Wholesale Citizens Awareness Network 3

Electric Company P.O. Box 83 l P.O. Box 426 Shelburne Falls, MA 03170 Ludlow, MA 01056 i Senior Resident Inspector i 2

Ernest C. Hadley, Esquire Millstone Nuclear Power Station

1040 B Main Street c/o U.S. Nuclear Reguatory Commission

! P.O. Box 549 P.O. Box 513 .

j West Wareham, MA 02576 Niantic, CT 06357 l 4

Joseph R. Egan, Esq.

Egan & Associates, P.C.

2300 N Street, NW j Washington, D.C. 20037

) Mr. J. K. Thayer

! Recovery Officer, Nuclear Engineering and Support Northeast Utilities Service Company P. O. Box 128 Waterfod, CT 06385 l