* Public Service Electric and Gas Company 80 Park Place Newark, N .J. 07101 Phone 201 /430-7000 March 31, 1980 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention:
                                          *
Mr. Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Gentlemen:
* Public Service Electric and Gas Company 80 Park Place Newark, N .J. 07101 Phone 201 /430-7000 March 31, 1980 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.               20555 Attention:             Mr. Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Gentlemen:
INTEGRATED LEAKAGE RATE TEST OF CONTAINMENT NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 In accordance with lOCFR Part 50, Appendix J, we hereby transmit twelve (12) copies of the Integrated Leakage Rate Test of tainment Report. Should you have any questions, please do not hesitate to contact us. Attachment Very truly yours, Frank P.
INTEGRATED LEAKAGE RATE TEST OF CONTAINMENT NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 In accordance with lOCFR Part 50, Appendix J, we hereby transmit twelve (12) copies of the Integrated Leakage Rate Test of Con-tainment Report.
General Manager -Electric Production s 1/ rJ. CENTENNIAL OF LIGHT  
Should you have any questions, please do not hesitate to contact us.
.-. u* *": 1879 1979 95-2001 (300M) 1-79}}
Very truly yours,
                                                                ~
Frank P. Libr~zzi General Manager -
Electric Production Attachment Ao1~
s 1/ rJ.
CENTENNIAL OF LIGHT
                                                                  .80040803~0
                                                                                    .-. u* *":
1879 1979 95-2001 (300M) 1-79}}

Revision as of 14:29, 21 October 2019

Forwards Reactor Containment Integrated Leak Rate Test, First Retest - Aug 1979.
ML18082A120
Person / Time
Site: Salem PSEG icon.png
Issue date: 03/31/1980
From: Librizzi F
Public Service Enterprise Group
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML18082A121 List:
References
NUDOCS 8004080390
Download: ML18082A120 (1)


Text

...-.

  • Public Service Electric and Gas Company 80 Park Place Newark, N .J. 07101 Phone 201 /430-7000 March 31, 1980 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Gentlemen:

INTEGRATED LEAKAGE RATE TEST OF CONTAINMENT NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 In accordance with lOCFR Part 50, Appendix J, we hereby transmit twelve (12) copies of the Integrated Leakage Rate Test of Con-tainment Report.

Should you have any questions, please do not hesitate to contact us.

Very truly yours,

~

Frank P. Libr~zzi General Manager -

Electric Production Attachment Ao1~

s 1/ rJ.

CENTENNIAL OF LIGHT

.80040803~0

.-. u* *":

1879 1979 95-2001 (300M) 1-79