Forwards Reactor Containment Integrated Leak Rate Test, First Retest - Aug 1979.
ML18082A120
Person / Time
Site: Salem PSEG icon.png
Issue date: 03/31/1980
From: Librizzi F
Public Service Enterprise Group
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML18082A121 List:
References
NUDOCS 8004080390
Download: ML18082A120 (1)


Text

...-.

Public Service Electric and Gas Company 80 Park Place Newark, N .J. 07101 Phone 201 /430-7000 March 31, 1980 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Gentlemen:

INTEGRATED LEAKAGE RATE TEST OF CONTAINMENT NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 In accordance with 10CFR Part 50, Appendix J, we hereby transmit twelve (12) copies of the Integrated Leakage Rate Test of Con-tainment Report.

Should you have any questions, please do not hesitate to contact us.

Very truly yours,

~

Frank P. Libr~zzi General Manager -

Electric Production Attachment Ao1~

s 1/ rJ.

CENTENNIAL OF LIGHT

.80040803~0