{{#Wiki_filter:FORMNIS-1OWNERS'ATAREPORTFORINSERVICEINSPECTIONSMarch25,1996Page1of71.Owner:2.Plant:FloridaPowerandLightCompanyP.O.Box529100Miami,Florida33152St.LucieNuclearPowerPlant6501SouthHighwayAlAJensenBeach,Florida349573~PlantUnit:~4~5OwnerCertificateofAuthorization(ifrecpxired)CommercialServiceDate6~7~NationalBoardNumberforUnit:ComponentsIn'spected:ComponentorAppurtenanceManufacturerManufacturerorInstallerorInstallerSerialNoStateorProvinceNo.Nat'lBoardNo.ReactorVesselPressurizerSteamGenerator2ASteamGenerator2BLetdownHeatExchangerCombustionEnineerinCombustionEnineeringCombustionEnineerinCombustionEngineerinEbasco711727137271272-171272-2N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AReactorCoolantPum2BlByronJackson741-N-003N/AN/AReactorCoolantPipingEbascoI-42-RC-123I-30-RC-121I-12-RC-147I-12-RC-154I-10-RC-302I-4-RC-101I-4-RC-103I-3-RC-309I-3-RC-310I-2-RC-122I-2-RC-125I-2-RC-149N/AN/Al,9'b04i50i259b040iPDRADQCK05000389',PDR8 i3.4.5.6.NIS-1Report(continued)Owner:FloridaPowerandLightCompany,P.O.Box529100,Miami,Florida33152Plant:St.LucieNuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)NationalBoardNumberforUnit:Page2of7ComponentorAppurtenanceManufacturerorInstallerManufacturerorInstallerSerialNo.StateorProvinceNo.Nat,'BoardNo.SafetyInjectionPipingEbasco/FPLI-12-SI-151I-10-SZ-127I-10-SI-130I-6-SZ-516I-6-SI-518I-6-SZ-113I-3-SI-179I-3-SI-191I-2-SI-109I-2-SI-215N/AN/AChemicalandVolumeControlPipingFPLI-2-CH-104I-2-CH-145I-2-CH-146I-2-CH-347N/AN/AShutdownCoolingHeatExchanger2AFeedwaterPipingEbascoFPLN/AI-18-BF-51I-18-BF-52N/AN/AN/AN/A8.ExaminationDates:Fro9~InspectionPeriodIdentification:FirstPeriod-10.InspectionIntervalIdentification:SecondInterval,fromtaalllkL-11.ApplicableEditionofSectionXI~39Addenda~ng12.Date/RevisionofInspectionPlan:13.Abstractofexaminationsandtest.Includealistofexaminationsandtestsandastatementconcerningstatusofworkrecpliredfortheinspectionplan.AnInserviceExaminationofselectedClass1,2,and3componentsandpipingsystemsofFloridaPowerandLightsSt.LucieUnit2NuclearPowerPlantwasperformedduringthe1995RefuelingOutage.ThisoutagebeganonOctober9,1995andendedon
{{#Wiki_filter:FORM  NIS-1 OWNERS'ATA            REPORT FOR INSERVICE INSPECTIONS March 25, 1996                                                          Page 1  of 7
: 1.     Owner:      Florida      Power and    Light  Company P.O. Box 529100 Miami, Florida          33152
: 2.     Plant:       St. Lucie Nuclear Power Plant 6501 South Highway AlA Jensen Beach, Florida 34957 3 ~     Plant  Unit:~
4 ~     Owner  Certificate of Authorization              (if recpxired) 5      Commercial Service Date 6 ~     National Board      Number      for Unit:
7 ~     Components    In'spected:
Component    or              Manufacturer Manufacturer          State or Nat'l Appurtenance                                  or Installer or Installer Serial                Province Board No      No.       No.
Reactor Vessel                Combustion      71172              N/A        N/A En ineerin Pressurizer                  Combus tion      71372              N/A        N/A En ineering Steam Generator  2A          Combustion      71272-1            N/A        N/A En ineerin Steam Generator  2B          Combustion      71272-2            N/A        N/A Engineerin Letdown Heat Exchanger        Ebasco          N/A                N/A        N/A Reactor Coolant  Pum  2Bl Byron Jackson      741-N-003          N/A        N/A Reactor Coolant Piping        Ebasco          I-42-RC-123        N/A        N/A I-30-RC-121 I-12-RC-147 I-12-RC-154 I-10-RC-302 I-4-RC-101 I-4-RC-103 I-3-RC-309 I-3-RC-310 I-2-RC-122 I-2-RC-125 I-2-RC-149 l,
9'b04i50i25 9b040i 05000389  ',
PDR  ADQCK 8                  PDR


1~2.3.4~5.6.NIS-1Report(continued)Owner:FloridaPowerandLightComPany,P.O.Box529100,Miami,Florida33152Plant:St~LuciaNuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)NationalBoardNumberforUnit:Page3of7January4,1996.Thiswasthesecondoutageofthefirstperiodofthesecondtenyearinterval.ThecomponentsandpipingsystemsexaminedwereselectedinaccordancewiththeSt.LucieSecondTenYearInserviceInspectionProgram,whichwaspreparedinaccordancewiththerequirementsofthe1989EditionofASMESectionXI.Manualultrasonic,radiographic,visual,magneticparticle,andliquidpenetrantnon-destructivetechniqueswereusedtoexaminecomponents,piping,andtheirsupports.TheexaminationswereperformedbyFPLpersonnel,supportedbyexaminerssuppliedbyRaytheonEngineersandConstructors.Alistingofexaminationsperformedisattachedtothissummary.EddyCurrentexaminationsonSteamGeneratorsAandBwereconductedbyFPLpersonnelfromNovember1,1995throughNovember9,1995.Atotalof16,355tubeswereexamined.FivetubeswerepluggedinSteamGeneratorAand11tubespluggedinSteamGeneratorBduringthisoutage.SeetheattachedNIS-BBreportforthesummaryofexaminationresults.SnubberfunctionaltestingandvisualexaminationswereconductedinaccordancewithSt.LuciePlantTechnicalSpecifications.ExaminationandtestingservicesweresuppliedbyWyleLaboratory,Inc.Seetheattachedreportforthesummaryofexaminationresults.SystemPressuretestingwasconductedbytheplanttoapplicablePlantTechnicalSpecificationsandProcedures.TheexaminationsperformedforthefirstperiodmeetorexceedtherequirementsofProgramBofSectionXI.SeetheattachedExaminationTablesforalistingofexaminationsperformed.14.AbstractofConditionsNotedectoesTheReactorPressureVesselstuds,nuts,washers,threadsintheflange,andweldswereexaminedwithvisual,magneticparticle,  
NIS-1 Report (continued)                             Page 2  of 7 i          Owner:
,3.4~5~6.NIS-1Report(continued)Owner:FloridaPowerandLightCompany,P.O.Box529100,Hiami,Florida33152Plant:St.LucieNuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)CamercialServiceDate:NationalBoardNwherforUnit:Page4of7andultrasonictechniques.Oneacceptablelinearindicationwasfoundononenut.Acceptablecorrosionandpittingwasfoundonallwashers.Noreportableindicationswerefound.Theflangetoshellweldwasexaminedwithultrasonictechniques.Noreportableindicationswerefound.SeetheNIS-BBreportforSteamGeneratoreddycurrent.results.Pressurizernozzletoflangewelds,nozzletoheadwelds,andinnerradiussectionswereexaminedusingpenetrantandultrasonictechniques.Acceptableslaginclusionswerefoundinonenozzletoheadweld.Onesafetyvalveflangeboltwasfoundtohaveacceptableincompletethreadengagement.Noreportableindicationswerefound.ReactorCoolantpipingweldsandboltingwereexaminedusingvisual,magneticparticle,penetrant,andultrasonictechniques.Noreportableindicationswerefound.Visual,surface,andultrasonicexaminationswereperformedonSafetyInjectionweldsandcomponentsupports.Geometricindicationswererecorded.Onespringsupportwasfoundwithsettingsoutsidetolerances.Noreportableindicationswerefound.Valveboltingandinternalsurfaceswereexaminedwithvisualtechniques.Noreportableindicationswerefound.~~Visual,surface,andultrasonicexaminationswereperformedonshutdowncoolingweldsandcomponentsupports.Geometricindicationswererecorded.Noreportableindicationswerefound.  
Plant:
,3.4.5~6.NIS-1Report(continued)Owner:FloridaPowerandLightComPany,P.O.Box529100,Hiami,Florida33152Plant:St.LuciaHuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)NationalBoardHumberforUnit:Fage5of7Onespringsupportwasfoundtohavealooselocknutandincompletethreadengagement.Noreportableindicationswerefound.Valveinternalsurfaceswereexaminedwithvisualtechniques.ValveV-3217wasfoundtohavewearonthebodyanddiskseatarea.Noreportableindicationswerefound.Visualandsurfaceexaminationswereperformedonpressurizerauxiliarysprayweldsandcomponentsupports.Noreportableindicationswerefound.915UR+~I.Visual,surface,andultrasonicexaminationswereperformedonSafetyInjectionwelds,componentsupports,andintegralattachments.Geometricindicationswererecorded.Oneacceptableroundindicationwasrecorded.Noreportableindicationswerefound.too'Magneticparticleandultrasonictechniqueswereusedtoexaminetheshutdowncoolingheatexchanger"A".Noreportableindicationswerefound.MainFeedwaterintegralattachmentweldswereexaminedusingmagneticparticletechniques.Noreportableindicationswerefound.Chargingpipingweldswereexaminedusingliquidpenetranttechniques.Noreportableindicationswerefound.
Florida Power and Light Company, P.O.
I,3~4~5.6.NIS-1Report(continued)Owner:FloridaPowerandLightCompany,P.O.Box529100,Hiami,Florida33152Plant:St.LucieNuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)ConnercialServiceDate:NationalBoardNumberforUnit:Page6of7TwoinchvalveV-2169,locatedinthechargingsystem,wasreplacedduringthisoutage.Baselineexaminationswereperformedonthenewpipingwelds.15.AbstractofCorrectiveMeasuresRecommendedandTakenThespringsupportfoundtohavesettingsoutsidetoleranceswasreset.Afollow-upvisualexaminationconfirmednootherrecordableindications.0Thelooselocknutandincompletethreadengagementononespringsupportweretightened.Afollow-upvisualexaminationconfirmednootherrecordableindications.ValveV-3217waslappedtoremovethewearareasnoted.Anewdiskwasalsoinstalled.Afollow-upexaminationconfirmednootherrecordableindications.
St. Lucie Nuclear Power Plant Box 529100, Miami, Florida 33152 6501 South Highway A1A, Jensen  Beach, Florida 34957
,3.4.5.6.NIS-1Report(continued)Owner:FloridaPowerandLightCompany,P.O.Box529100,Hiami,Florida33152Plant:St.LucieNuclearPowerPlant6501SouthHighwayA1A,JensenBeach,Florida34957PlantUnit:~OwnerCertificateofAuthorization(ifrequired)NationalBoardNumberforUnit:Page7of7Wecertifythata)thestatementsmadeinthisreportarecorrect,b)theexaminationsandtestsmeettheInspectionPlanasrequiredbytheASMECode,SectionXI,andc)correctivemeasurestakenconformtotherulesoftheASMECode,SectionXI.CertificateofAuthorizationNo.ExpirationDateDate:Signed:ByCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvinceofSt.LucieCounty,Florida,andemployedbyArkwrightMutualInsuranceCompanyofNorwood,Massachusetts,haveinspectedthecomponentsdescribedinthisOwner'sReportduringtheperiod10/9/95to1/4/96,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtestsandtakencorrectivemeasuresdescribedintheOwner'sDataReportinaccordancewiththeInspectionPlanandasrequiredbytheASMECode,SectionXI.Bysigningthiscertificate,neithertheinspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminations,tests,andcorrectivemeasuresdescribedinthisOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnectedwiththisinspection.Inspctor'sSignatureDate:~5-47-'P4u/s~~NationalBoard,State,Province,andEndorsements
: 3.       Plant  Unit:~
: 4.       Owner  Certificate of Authorization (if required) 5.
: 6.       National Board  Number for Unit:
Component      or                Manufacturer Manufacturer                      State or Nat,'
Appurtenance                        or Installer Serial  or Installer            Province Board No.         No.         No.
Safety Injection Piping            Ebasco/FPL            I-12-S I-151            N/A        N/A I-10-SZ-127 I-10-SI-130 I-6-SZ-516 I-6-SI-518 I-6-SZ-113 I-3-SI-179 I-3-SI-191 I-2-SI-109 I-2-SI-215 Chemical and Volume                FPL                  I-2-CH-104              N/A        N/A Control Piping                                            I-2-CH-145 I-2-CH-146 I-2-CH-347 Shutdown Cooling Heat              Ebasco                N/A                    N/A        N/A Exchanger 2A Feedwater Piping                  FPL                  I-18-BF-51              N/A        N/A I-18-BF-52
: 8.       Examination Dates                :    Fro 9  ~    Inspection Period Identification                        :    First Period
: 10.     Inspection Interval Identification: Second Interval, from taalllkL-
: 11.     Applicable Edition of Section XI ~39 Addenda ~ng
: 12.     Date/Revision of Inspection Plan:
: 13.      Abstract of examinations and test. Include a list of examinations and tests and a statement concerning status of work recplired for the inspection plan.
An    Inservice Examination of selected Class 1, 2, and 3 components and    piping systems of Florida Power and Light s St. Lucie Unit 2 Nuclear Power Plant was performed during the 1995 Refueling Outage.         This outage began on October 9, 1995 and ended on


St.LucieUnit2~~DocketNo.50-389Fall1995RefuelingOutageNIS-j.ATTACHMENTj.EXAMINATIONTABLES DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:120NENUHBER:2-001SUMHARYEXAHIHATIONAREANUHBERIDENTIFICATIOHASHESEC.XICATGYEXAHITEMNOHETHOOPROCEDUREHI0OHGTRSEHEI0EREMARKSCGHR**CALIBRATIOHBLOCK**REF.DUG.NO.02-001-002000'101-121UPPERSHELLTOFLANGEMELOBAUT1.5B1.30UT5.7UT12.5NDE5.12-1NDE5.12-2NDE5.12.3X---X---X.--10/19/95-UTcomplete,examinationperformedfromtheflangesurface,examinationfromtheshellsidewillbeperformedatalatertime**UT-1,UT-8**REF.DUG.No.02-001c006300S-01ATHRUS54ARPVSTUDS1THRU54B-G186.30HTHTHTVT.'IVT-1UT.45UT-80UT-45UT-80UT-45UT-80UT-45HDE2.2.31,32NDE2.2-35,36NDE2.2-37NDE4.1.34,36HDE4.1-38NDE5.7.13,14HDE5.7-15,16NDE5.7-17,18NDE5.7-19NDE5.7-20,21NDE5.7-22HDE5.7-23,24X---04/25/95-HT,VT-1,andUTcomplete,X---examinedgroup"A"studs1thru54X---X---X--->>>>7-1.125-8-CS-52-SLC>>>>XXX-X---X---X---X---006500N-01ATHRUN54ARPVHUTS1THRU54B-G.186.30HTHTUT-45UT-45UT-45HDE2.2-31,33HDE2.2.34,38NDE5.10-1NDE5.10-2NDE5.10-3---X4/25/95-MTandUTcomplete,examined---Xgroup>>A"nuts1thru54,oneacceptableX---linearindicationX---X---**UT-51**006700W-OIATHRUM-54ARPVIIASHERS1THRU54B-G-1VT-186.50VT-1VT-1NDE4.1-35HDE4.1-37HDE4.1-39X---4/25/95-VT-'Icomplete,examinedgroup---XeA"washers1thru54,acceptable---Xcorrosionandpitting006900FL-01THRUFL-54THREADSIHRPVFLANGEB-G-1UT0HDE5.12-486.40X.--10/19/95-UTcomplete,examinationperformedfromthesealsurface**UT8**
NIS-1 Report (continued)                            Page 3 of 7 1 ~     Owner:  Florida  Power and Light ComPany, P.O. Box 529100, Miami, Florida 33152
: 2.     Plant:   St ~ Lucia Nuclear Power Plant 6501 South Highway A1A, Jensen Beach, Florida  34957
: 3.     Plant  Unit:~
4~      Owner  Certificate of Authorization  (if required) 5.
: 6.      National Board Number for Unit:
January 4, 1996.               This was the second outage of the first period of the second ten year interval.
The components and piping systems examined were selected in accordance with the St. Lucie Second Ten Year Inservice Inspection Program, which was prepared in accordance with the requirements of the 1989 Edition of ASME Section XI.
Manual    ultrasonic, radiographic, visual, magnetic particle, and liquid penetrant non-destructive techniques were used to examine components, piping, and their supports.                               The examinations were performed by FPL personnel, supported by examiners supplied by Raytheon Engineers and Constructors.                             A listing of examinations performed is attached to this summary.
Eddy    Current examinations on Steam Generators A and B were conducted by FPL personnel from November 1, 1995 through November 9, 1995. A total of 16,355 tubes were examined.                                     Five tubes were plugged in Steam Generator A and 11 tubes plugged in Steam Generator B during this outage. See the attached NIS-BB report for the summary of examination results.
Snubber functional testing and visual examinations were conducted in accordance with St. Lucie Plant Technical Specifications.
Examination and testing services were supplied by Wyle Laboratory, Inc. See the attached report for the summary of examination results.
System Pressure            testing was conducted by the plant to applicable Plant Technical Specifications and Procedures.
The examinations performed for the first period meet or exceed the requirements of Program B of Section XI.
See the attached Examination Tables for a listing of examinations performed.
: 14. Abstract of Conditions Noted e cto        es The Reactor Pressure Vessel studs, nuts, washers, threads in the flange, and welds were examined with visual, magnetic particle,


DATE:02/23/96REVISION:0Generator2APrimerSideST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOHPONENTSPAGE:2ZONENUMBER:2-003SUHHARYEXAHINATIONAREANUMBERIDENTIFICATIONASHESEC.XICATGYEXAHITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGHR**CALIBRATIONBLOCK*"REF.D'IJG.NO.02-003015700TUBEBUNDLEU-TUBESB-0ECTB16.20NDE1.3---X11/9/95-8,142tubesexamined,236indications,fivetubepluggedthisoutageduetoHRPCEZIindications DATE:02/23/96REVISION:0Generator2BPrimerSideST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:3ZONENUMBER:2-004SUMMARYEXAMINATIONAREANUMBERIDEHTIFICATIOHASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSENEI0EREMARKSCGMR*"CALIBRATIONBLOCK**REF.DWG.NO.02-004'18600TUBEBUNDLEU-TUBESB-QECTB16.20HDE1.3---X11/9/95-8,213tubesexamined,156indications,seventubespluggedthisoutageforcorrosionandwearprogression DATE:02/23/96REVISION:0RIZERST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:4ZONENUMBER:2-005SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0OHGTRSEHEI0EREMARKS,CGMR**CALIBRATIONBLOCK**REF.DWG.HO.02-005-B018700103-601SPRAYNOZZLETOUPPERHEAD8-DUT0B3.110UT45UT60UT70HDE5.1-25NDE5.1-26HDE5.1-27HDE5.1-28X---10/23/95.UTcompleteX---X--X---**UT-4A**REF.DMG.NO.02-005-A018800SN-IRSPRAYNOZZLEINNERRADIUSSECTIONB.DUT30B3.120UT70NDE5.13-4HDE5.13-6X---10/23/95-UTcompleteX---**UT-6,UT-17">>REF.DMG.NO.02-005-B108-601-ASAFETYVALVENOZZLETOHEAD8-D83.110UT0UT45UT60UT70UT60UT70HDE5.1-29NDE5.1-30HDE5.1-31HDE5.1-32HDE5.1-33HDE5.1-34X---10/24/95-UTcomplete,acceptableslagX---X---X---X**UT-4A**--XREF.DWG.NO.02005A019000SVN-IR-ASAFETYVALVENOZZLEINNERRADIUSSECTIONB-DUT3083.120UT70HDE5.13-3NDE5.13-5X---10/23/95-Ul'ompleteX-*>>UT-6,UT-17*019100503-671-ANOZZLETOFLANGEB-FPTB5~40UT30UT45UT45HDE3.3-44HDE5.4-56HDE5.4-57HDE5.4-58X--X-X--X--10/20/95-PTcomplete,10/21/95-UTcomplete,limitedexaminationfromthenozzlesideduetoitsconfiguration**UT-17>>*
, 3.
DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUHIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE!5RIZERNUMBER!2-005SUMMARYEXAMINATIONAREAHUHBERIDENTIFICATIONASMESEC~XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK**REF.DWG.HO.02-005-A019200SV-1200B-G.2VT-1SAFETYVALVEFLANGEBOLTING87.50CNRHDE4.1-2995-2-004---X10/25/95-VT-1complete,inadequatethreadengagementononenut,acceptableperletterJPN-PSL-88-070REF.DWG.NO.02-005-8019300108-601-88-DUT0RELIEFVALVENOZZLETOUPPER83.110UT45HEADUT60UT70NDE5.1.25NDE5.1-26NDE5.1-27NDE5.1-28X--X---X---X---10/23/95-UTcomplete**UT-4A<<*REF.DWG.NO.02-005-A019400RVH-IRRELIEFVALVENOZZLEIHNERRADIUSSECTIONB-DUT30NDE5.13-383.120UT70HDE5~13-5X---10/23/95-UTcompleteX.--<<<<UT-6,UT-17<<*REF.DWG.HO.02-005-8019500108-601-C8-DUT0SAFETYVALVENOZZLETOUPPER83.110UT45HEADUT60UT70NDEF1-25HDEF1-26NDE5.1-27HDE5.1-28X---X---X---X---10/23/95-UTcomplete**UT-4A"*REF.DWG.HO.02-005-A019600SVH-IR-8SAFETYVALVENOZZLEINNERRADIUSSECTION8-DUT30NDE5.13-383.120UT70NDE5'3-5X---10/23/95-UTcoapleteX---<<*UT-6)UT-17*
4~
Owner:
Plant:
Plant Owner NIS-1 Report (continued)
Florida Power and Light Company, P.O.
St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~
Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)
Florida 33152 Page 4 of 7 5~    Camercial Service Date :
: 6. National Board Nwher for Unit:
and  ultrasonic techniques.                   One    acceptable linear indication was found on one nut. Acceptable corrosion and pitting was found on all washers. No reportable indications were found.
The flange to shell weld was examined with ultrasonic techniques.
No reportable indications were found.
See  the NIS-BB report for Steam Generator eddy current. results.
Pressurizer nozzle to flange welds, nozzle to head welds, and inner radius sections were examined using penetrant and ultrasonic techniques. Acceptable slag inclusions were found in one nozzle to head weld. One safety valve flange bolt was found to have acceptable incomplete thread engagement. No reportable indications were found.
Reactor Coolant piping welds and bolting were examined using visual, magnetic particle, penetrant, and ultrasonic techniques.
No reportable indications were found.
Visual, surface, and ultrasonic examinations were performed on Safety Injection welds and component supports. Geometric indications were recorded. One spring support was found with settings outside tolerances. No reportable indications were found.
Valve bolting and internal surfaces were examined with visual techniques. No reportable indications were found.
                              ~  ~
Visual, surface, and ultrasonic examinations were performed on shutdown cooling welds and component supports.                                 Geometric indications were recorded. No reportable indications were found.


DATE:02/23/96REVISION:0RIZERST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:6ZONENUMBER:2005SUMMARYEXAMIHATIOHAREANUMBERIDENTIFICATIONASMESEC~XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK*"REF.DWG.NO.02-005-A019700503-671-88-FSAFETYVALVENOZ2LETOFLANGE85.40PTUT30UT45UT45NDE3.3-44HDE5.456HDE5.4-57HDE5.4-58X--XX--X--10/20/95-PTconplete,10/21/95UTcomplete,limitedexaminationfromthenozzlesideduetoitsconfiguration**UT-17*019800SV-12018-G-2VT-1SAFETYVALVEFLANGEBOLTIHGB7.50HDE4~1-28X---10/25/95-VT-1complete,8nutsandstudsexaminedREF.DUG.No.02-005-B019900108-601-0B-DUI'SAFETYVALVENOZZLETOUPPERB3.110UI'5HEADUT60UT70NDE5.1-25NDE5.1-26HDE5.'1-27NDE5.1-28X---10/23/95-UTcompleteX---X---X---<<<<UT-4A<<<<REF.DUG.NO.02-005-A020000SVN-IR-CSAFETYVALVENOZZLEINNERRADIUSSECTION8-DUT3083.120UT70NDE5.13-3HDE5.13-5X---10/23/95-UTcompleteX---<<*UT-6(UT-17*020100503-671-C8-FPTSAFETYVALVENOZZLETOFLANGEB5.40UT30UT45UT45HDE3.3-44HDE5.4-56HDE5.4-57NDE5.4-58X--X--X-X--10/20/95-PTcomplete,10/21/95UTcomplete,limitedexaminationfromthenozzlesideduetoitsconfiguration<<*UT17*<<020200SV-12028-G-2VT-1NDE4.1.27SAFETYVALVEFLANGEBOLTING87.50X---10/25/95-VT-1complete Ii00 DATE:02/23/96REVISION:0RIZERST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS'ICAEPBLSTATUSCOMPONENTSPAGE7ZONENUHBER:2-005SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDUREHI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK<<>>REF.DWG.NO.02-005-8020300MS-01MANWAYSTUDS8-G-2VT187.20M95-368X---11/15/95-VI'-1complete,examined20studs,examinationperformedbyQCpersonnel020400MN-01MANWAYNUTS8-G-2VT-187.20M95-368X---11/15/95-VT-1complete,examined20nuts,examinationperformedbyQCpersonnelREF.OWG.NO.02-005-A020500501-671UPPERHEADTOUPPERSHELL8-882.11UT0UT45UT60UT70NDE5.1-21HDE5~1-22HDE5.1-23NDE5.1-24X---10/21/95-UTcompleteX---X---X---<<*UT-4A**0101-622.A88UPPERSHELLLOHGITUDIHALWELD'2.1290DEG.UT0UI'5UT60UT70NDE5.1-21HDE5.1-22NDE5.1-23HDE5.1-24X---10/21/95-UTcompleteX-X---X---**UT-4A**WATERSPACENOZZLESREF.DWG.HO.02-005-8022000672-102LERVT-1TEMPERATURENOZZLE90DEGREES93-04HDE4.1-'17X---10/9/95-VT-1complete,noevidenceofleakageI-1-RC-130REF.DWG.NO.02-005022100V-1437INSTRUMENTATIONVALVEPRZIHCVT-1AUG-1HDE4.1-24X---10/9/95-VT-'Icerpiete Jl DATE:02/23/96REVISION:0RIZERST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPOHENTSPAGE:8ZOHENUMBER:2-005SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREHARKSCGMR**CALIBRATIONBLOCK**REF.DWG.HO.02-005-B022200HA1THRUHA4HEATERPEHETRATIONSLERVT-'I93-04HDE4.1-19---X10/9/95-VT-1complete,whitesubstancefoundonvesselnearheaterpenetrationA3,notboricacidSTEAMSPACENOZZLESREF.DWG.NO.02-005-B022300672-105ALEVELNOZZLE90DEGREESLERVT-193-04NDE4.1-23X---10/16/95-VT-1complete022350672-105ANOZZLETOVESSELWELD90DEGREESB-EUT6084.13NDE5.22-13X---10/23/95-UTcomplete*~UT-62,Ul'-70**0672-105BLERVT-1NDE4.1-22X---10/16/95-Vl'-1completeLEVELNOZZLE8180DEGREES93-04022450672-1058B.EUT60NDE5.22-13NOZZLETOVESSELWELD9'IBOB4.13DEGREESX---10/23/95-UTcomplete*~UT62)UT-70**022500672-105CLERVT-1LEVELNOZZLEB195DEGREES93-04NDE4.1-21X---10/16/95-VT-1complete022550672-105CB-EUT60NDE5.22-13NOZZLETOVESSELWELD9195B4~13DEGREESX---10/23/95-UTcomplete"*UT-62(UT-70**
, 3.
4.
Owner:
Plant:
Plant Owner NIS-1 Report (continued)
Florida Power and Light ComPany, P.O.
St. Lucia Huclear Power Plant 6501 South Highway A1A, Jensen Unit:~
Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)
Florida 33152 Fage 5 of 7 5~
: 6. National Board Humber for Unit:
One  spring support was found to have a loose lock nut and incomplete thread engagement.                     No reportable indications were found.
Valve internal surfaces were examined with visual techniques.
Valve V-3217 was found to have wear on the body and disk seat area. No reportable indications were found.
Visual and surface examinations were performed                                on  pressurizer auxiliary spray welds and component supports.                                 No  reportable indications were found.
915UR+~I.
Visual, surface,           and ultrasonic examinations were performed on Safety Injection welds, component supports, and integral attachments.           Geometric indications were recorded.                           One acceptable round indication was recorded. No reportable indications were found.
t  o          o '
Magnetic      particle and ultrasonic techniques were used to examine the shutdown cooling heat exchanger "A". No reportable indications were found.
Main Feedwater          integral attachment welds were examined using magnetic      particle techniques. No reportable indications were found.
Charging piping welds were examined using                            liquid penetrant techniques.           No  reportable indications were found.


DATE:02/23/96REVISION:0RIZERST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECOHDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPOHENTSPAGE:9ZONENUMBER:2-005SUMMARYEXAMIHATIOHAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDUREHI0OHGTRSEHEI0EREHARKSCGMR**CALIBRATIONBLOCK**STEAMSPACENOZZLESREF.DWG.NO.02-005-B022600672-105DLERVT-1LEVELNOZZLE9345DEGREES93.04NDE4.1-20X---10/16/95-VT-1canplete022650672-105DB-EUT60NDE5.22-13NOZ2LETOVESSELWELD934584.13DEGREESX---10/23/95-UTcomplete**UT-62,UT-70**WATERSPACENOZZLESREF.DWG.NO.02-005-B022700684-108ALEVELNOZZLE90DEGREESBOTTOMHEADLERVT-'I93-04HDE4.1.16X---10/9/95-VT-1cceplete,noevidenceofleakage022800684-1088LEVELNOZZLE9180DEGREESBOTTOMHEADLERVT-193-04NDE4.1-18X---'ID/9/95-VT-1co@piete,noevidenceofleakage IIf'ltly DATE:02/23/96REVISIGH:0ST.LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSRCOOLANTPIPINGLOOPBFROMRPVTOSG-2BPAGE:10ZONENUMBER:2-007SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIOHBLOCK**I-42-RC-123REF.DWG.NO.02-007024300RC-123-201-258NOZZLEEXTEHSIOHTOST.GEHERATORNOZZLE8-JMTB9.11UT45UT60NDE2.2-28NDE5.2-36NDE5.2-36X---10/18/95-MTcomplete,10/19/95-UTX---completeX.--**UT-4A**
I,3~
DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOHPONENTSRCOOLANTPIPINGLOOPBSG-2BTORCP-2B1PAGE:11ZONENUHBER:2-010SUHHARYEXAHIMATIONAREANUHBERIDENTIFICATIONASHESEC~XICATGYEXAHITEMNOHETHODPROCEDURENI0ONGTRSENEI0EREHARKSCGHR~*CALIBRATIONBLOCK**I-30-RC-121REF.DWG.NO.02-010027200RC-121-401-258-8B-JMTST.GENERATORNOZZLETONOZZLE89.11UT45EXTENSIONUT60NDE2.2-29NDE5.2-37NDE5.2-38X---10/18/95-HTcomplete,10/19/95UTX---complete,limitedexaminationfromtheX---nozzlesideduetoitsconfiguration**UT6~*028600RC-121-107-742.LS.AELBOWLONGITUDINALSEAH8-JPTB9.12UT45UT60NDE3.3-43NDE5.4-68NDE5.4-69X---10/19/95-PTcomplete,10/20/95-UTX---complete,examinedareanexttoweldX---RC-121-1501-771-BA*UT028700RC-121-107-742-LS-8ELBOWLONGITUDINALSEAM8-JB9.12PTNDE3.3-43UT45NDE5.4-68UT60NDE5.4-69X---10/19/95-PTcomplete,10/20/95-Ul'---complete,examinedareanexttoweldX---RC-121-1501-771-B**UT6**0RC-121-1501-771-8ELBOWTOSAFEENDB-F85.130PTUT45UT45UT45UT60NDE3.3-43NDE5.4-66NDE5.4-67NDE5.4-68NDE5.4-69X---X---X---X---X---10/19/95-PTcomplete,10/20/95-UTcomplete,limitedexaminationonthesafe-endsideduetoitsconfiguration**UT-59)UT-6**028900RC-121-48-JPTNDE3.3.43SAFE-ENDTOREACTORCOOLANT89.11UT45NDE5.4-65PUMP281UT45NDE5.4-66X---X-X-10/'19/95-PTcomplete,10/20/95-UTcomplete,insidesurfacegeometry,limitedexaminationduetoweldconfiguration,examinedfromthesafe-endsideonly**UT59k*
4~
0 DATE:02/23/96REVISION:0ST~LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECOHDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSRCOOLANTPIPINGLOOPBFROMRCP-2B1TORPVPAGE:12ZONENUMBER:2-011SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSENEI0EREMARKSCGMR**CALIBRATIOHBLOCK**I-30-RC-121REF.DUG.HO.02-011029100RC-121-5REACTORCOOLANTPUMP281TOSAFE-END8-JPT89.11UT45UT45HDE3.3-41HDE5.4-70NDE5.4-72X---10/18/95-PTcoapiete,10/20/95-UT--X-complete,insidesurfacegeometryX--**UT59**029200RC-121-901-771SAFE-ENDTOPIPEB-F85.130PTUT45UT45UT60UT45NDE3.3-41NDE5.4-71NDE5.4-72NDE5.4-73NDE5.4-74X---X--X---X---X---10/18/95-PTcomplete,10/20/95UTcomplete**UT-59,UT-6~*029300RC-121-103-722-LS-APIPELOHGITUDIHALSEAMB-JPTB9.12UT45UT60NDE3.3-41NDE5.4-74NDE5.4-73X---10/18/95-PTcomplete,10/20/95-UTX---complete,examinedareanexttoweldX---RC-121-901-771**UT64*029400RC-121-103-722-LS-BPIPELONGITUDINALSEAM8J89.12PTHDE3.3-41UT60AXIALHDE5.4-73UT45CIRCNDE5.4-74X---10/18/95-PTcomplete,10/20/95-UTX---complete,examinedareanexttoweldX---RC-121-901-771**UT64*
5.
11L10 DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSA1SAFETYINJECTIONPIPINGINSIDEO'TMT20NENUMBER:2-021SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0OHGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK**I-6-SI-516REF.DWG.NO.02-021046200V-3258VALVEINTERNALSURFACEB-M-2VT-3B12.50NDE4.3-97X---10/23/95-VT-3complete DATE:02/23/96REVISION:0A2SAFETYINJECTIONPIPINGST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOHPONENTSINSIDECTMTPAGE14ZONENUMBER:2-022SUHMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAHITEHNOMETKODPROCEDURENI0ONGTRSENEI0EREMARKSCGMR<<*CALIBRATIONBLOCK**I-12-RC-154REF.DUG.NO.02-02205'1300V-3217CHECKVALVEBOLTING8-G-2VT-187.70VT-1NDE4.1-33MM95-1692X---11/1/95-VT-1complete,11/6/95-18X---studsandnutsexaminedinplace,examinationperformedbyQCpersonnel051400V-32'l7VALVEINTERNALSURFACEB-H-2VT-3B12.50CNRNDE4.3-10895-2-00611/1/95-VT-3complete,uearlocatedatvalveanddiskseatarea,bottomandsidesofbearingblockhousing,seatlappedandnewdiskinstalled
6.
'lI94~.'III DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDiNTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:15B2SAFETYINJECTIONPIPINGINSIDECTMTZONENUMBER:2-024SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK**1-12-SI-151REF.DIIG.HO.02-024058100V-3644GATEVALVEBOLTING8-G-2VT-187.70NDE4.1-30X---10/30/95-VT-1complete,18studsandnutsexamined058300SI-151-Fll-1VALVEV-3644TOPIPE8-JPT89.11UT45UT45UT60NDE3.3-57NDE5.4-98NDE5.4-99NDE5.4-100X--X--X----X10/30/95PTandUTcomplete,rootgeometry,limitedexaminationfromthepipesideduetotheweldconfiguration**UT354*058420SI-4203-581ARIGIDFRAMESUPPORTF-AVT-3F1.10HDE4.3-107X---10/30/95-VT-3complete1-6-SI-518REF.DWG.HO.02-02400V-3261CHECKVALVEBOLTINGB-G-2VT-187.70HDE4.1-31X---10/30/95-VT-1complete,16studsandnutsexamined058900SI-518-Fu-1VALVEV-3261TOPIPEB-J89.11PTUT45UT45UT60UT70HDE3.3-57HDE5.4-94NDE5.4-95NDE5.4-96NDE5.4-97X-X-~*UT-38**X---10/30/95-PTandUTcomplete,rootX---geometryX---1-12-S1-151REF.DMG.NO.02-024059740S1-4203-67SpringSupportF-AF1.50VT-3VT-3CNRSTARPMONOHDE4.3-106NDE4.3-'11295-2-005951638822295013842---X10/30/95-VT-3complete,11/8/95-VT-3X---re-examinationcompleteafteradjust PPg,+~t4I'ff0 DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:16B2SAFETYINJECTIONPIPINGINSIDECTMTZONENUMBER:2-024SUHHARYEXAMIHATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAHITEHHOHETKODPROCEDURENI0ONGTRSEHEI0EREMARKSCGHR<<<<CALIBRATIONBLOCK**I-12-SI-151REF.DMG.NO.02-024060100SI-4203-71INTEGRALATTACHHENTS8-K-1PT810.10HDE3.3-57X---10/30/95-PTcomplete,examined8integralattachmentsontheaccessable3sides060400SI-151-FH-4PIPETOVALVEV-3247B-JPTB9.11UT45UT45UT60HDE3.3-57NDE5.4.98HDE5'-99NDE5.4-100X---10/30/95-PTandUTcceplete,rootX---geometry,limitedexaminationfromtheX---pipesideduetotheweldconfiguration--X-*<<UT-35**
Owner:
lLl=rI DATE:02/23/96REVISION:0EDPRESSURIZERSPRAYLINEST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECOHDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:17ZONENUMBER:2-025SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIOHBLOCK**I-4-RC-103REF.DWG.HO.02-025063140SPS-787RIGIDSTRUTF-AVI'-3F1.10HDE4.3-96X---10/21/95-VT-3complete063600RC"103C-SW-1PipetoTee8-J89.11PTUT30UT45UT60HDE3.3-45HDE5.4-62HDE5.4-64NDE5.4-63X---10/20/95-PTcomplete,10/23/95-UTX---completeX---X-~~UT-40**063700RC-103C-SW-3ReducertoTee8-JPT89.11UT30UT45UT60NDE3.3-45HDE5.4-62HDE5.4-64NDE5.4-63X---X---X--X--10/20/95-PTcomplete,10/23/95-UTcomplete**UT-40**0RC-'I03C-SW-2TeetoPipe8-J89.11PTUT30UT45UT60NDE3.3-45NDE5.459NDE5.4-60NDE5.4-61X---10/20/95-PTcomplete,10/23/95UTX---complete,rootgeometry--X--X-**UT40**063900RC-103-FW-903PIPETOSAFE-END8-JPT89.11UT30UT45UT60NDE3.3-45HDE5.4-62NDE5.4-64HDE5.4-63X---10/20/95-PTcomplete,10/23/95-UTX---completeX---X.--**UT40**064000RC-504-671SAFE-EHDTOSPRAYNOZZLE8-FPT85.40UT45UT45NDE3.3.45NDE5.4-77HDE5.4-78X---10/20/95-PTcomplete,10/23/95UTX---complete,counterboregeometryX**U'I-19**
Plant:
IIII'C DATE:02/23/96REVISION:0.8SHUTDOWNCOOLINGLINEST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:1820NENUMBER:2-028SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK**I-12-RC-147REF.DMG.NO.02-028-A074600RC-147-1-SW-83"SllEEPOLETB-JPT89.32UT45UT45UT60NDE3.3-58NDE5.4-101NDE'5.4-102NDE5.4-103X---X---X-----X-10/31/95-PTandUTcomplete,rootgeometry**UT35**I-10-RC-302REF.DUG.NO.02-028-B076450SI-4205-6408SpringSupportF-AF1.50VT-3VT-3CNRPISMONDE4.3-109NDE4.3-11195-2-007822295013839---XX---11/2/95-VT-3complete,looselocknutandincompletethreadengagement,11/8/95VT-3re-examinationcompleteaftertightening076500SI-4205-6408INTEGRALATTACHMENTS8-K-1PT810.10NDE3.3-59X---11/3/95-PTcoaplete,limitedexaminationduetohangerclamp,examined3accessiblesidesI-10-SI-130REF.DUG.NO.02-028-8077600SI-130-1-SN.62"BRANCHCONNECTION8-JPT89.32NDE3.3-61X---1'I/14/95-PTcompleteI-3-SI-191REF.DUG.NO.02-028-A080700SI-191-FW.3PIPETOVALVEV-35278-JPT89.21NDE3.3-58X---10/31/95-PTcomplete080900SI-191-FN-2VALVEV-3527TOPIPE8-JPT89.21NDE3.3-58X---10/31/95-PTcomplete IIII'III,I DATE:02/23/96REVISION:0BSHUTDOWNCOOLINGLIMEST.LUCIENUCLEARPLANTUNIT2INSERVICEIHSPECTIOHRESULTSFORTHESECOHDINTERVAL,FIRSTPERIOD,SECOHDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSZONENUMBER:2-028SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIOHBLOCK">>I-3-SI-191REF.DWG.NO.02-028.A081000SI-191-1-S'W.1PipetoElbowB.JPT89.21NDE3.3-58X---10/31/95-PTcomplete081750SI-4206-6361RIGIDSTRUTSUPPORTF-AVT-3F1.10NDE4.3-110X---11/2/95-VT-3coaplete DATE:02/23/96REVISION:0ASHUTDOWNCOOLINGLINEST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSZONENUMBER:2-029SUMMARYEXAMINATIOHAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR<<<<CALIBRATIONBLOCK**1-10-SI-127REF.DWG.HO.02-029-B089300V-3481VALVEINTERHALSURFACE8-M-2VT.3812.50HDE4.3-98X---10/26/95-VT-3complete IlI DATE:02/23/96REVISION:0RIZERAUXILIARYSPRAYST.LUCIENUCLEARPLANTUHIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSZONENUMBER:2-030SUMMARYEXAMINATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK~*I-2-CH-146REF.DWG.NO.02-030-8091600CH-146SW-1VALVESE-02-03TOPIPE8-JPT89.21NDE3.3.49X---10/23/95-PTcomplete091700CH-146-SW-2PipetoTee8-JPT89.40NDE3.3-49X---10/23/95-PTcomplete09'1900CH-146-SW.4TeetoPipe8-JPT89.40NDE3.3-49X---10/23/95-PTcomplete092000CH-146-SW-58-JPT89.40NDE3.3-49X...'IO/23/95-PTcompleteI-2-CH-347REF.DWG.NO.02-030-8092100CH-347-SW-1VALVESE-02-04TOPIPE8-JPT89.21HDE3.3-49X---10/23/95-PTcceyiete092200CH-347-FW.2PipetoTee8-JPT89.40NDE3.3-49X.-.10/23/95-PTcompleteI-2-CH-146REF.DWG.NO.02-030-8092300CH-146-FW.6TeetoPipe8-JPT89.40NDE3.3.50X-.-10/23/95-PTcomplete
Plant Owner NIS-1 Report (continued)
~i'I1IL~I~
Florida Power and Light Company, P.O.
DATE:02/23/96REVISION:0RIZERAUXILIARYSPRAYST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVALEDFIRSTPERIODSSECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOHPONENTSPAGE:22ZONENUHBER:2-030SUHHARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAHITEHNOHETHOOPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK~~I-2-CH-146REF.DWG.NO.02-030-8092400CH-146-S'W-7PipetoTee8-JPT89.40NDE3.3-50X---10/23/95-PTcomplete092500CH-146-SW-10REDUCERTOELBOW8-JPT89.40NDE3.3-50X---10/23/95-PTcomplete092600CH-146-SW.9ElbowtoPipe8-JPT89.40NDE3.3-50X---10/23/95-PTcomplete092700CH-146.SW-B1092800CH-146-FW-11TeetoPipe8-JPT89.408-JPT89.40NDE3.3-49HDE3.3-49X---10/23/95-PTcompleteX---10/23/95-PTco@pieteI-2-CH-146REF.DWG.NO.02-030.093760CH-107-R7VARIABLESPRINGBASEF.AVT-3F1.50NDE4.3-104X---10/27/95-VT-3completeI-2-RC-149REF.DWG.NO.02-030-A094600RC-149-FW.2PipetoReducer8-FPT85.140NDE3.3-47X---10/20/95-PTcomplete E
St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~
DATE:02/23/96REVISION:0B1PRIMARYDRAIHST.LUCIENUCLEARPLANTUNIT2IHSERVICEIHSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:23ZONENUMBER:2-035SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR~*CALIBRATIONBLOCK**I-2-RC-122REF.DUG.HO.02-035111200RC-122.FN.1SAFE-EHDTOPIPE8-JPTB9.21NDE3.3-42X---10/19/95-PTcoagulate1118002-RC-122-FBFLANGEBOLTIHGB-G-2VT-187.50CNRNDE4.1-2695-2-003---X10/19/95-VT-1coaplete,oneboltflushwithnut,acceptableperengineeringevaluationJPH-PSL-88-070 DATE:02/23/96REVISION:082PRIMARYDRAINST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:24ZONENUMBER:2-036SUHHARYEXAMINATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGHR**CALIBRATIONBLOCK*"I-2-RC-125REF.OWG.NO.02-0361126002-RC-125-FBFLANGEBOLTINGB-G-2Vr-187.50NDE4~1-25X---10/19/95-VT-1complete 1kN41Ih DATE:02/23/96REVISION:0NLINEFROHLOOP281ST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTNESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE25ZONENUMBER:2-037SUHHARYEXAMINATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAMITEMNOHETHODPROCEDURENI0ONGTRSENEI0EREHARKSCGMR**CALIBRATIONBLOCK**I-2-CM-145REF.DUG.NO.02-037-B116900V-2516VALVEBOLTINGVT-1NDE4.1-32X---10/27/95-VT-1complete DATE:02/23/96REVISION:0RIZERRELIEFLINEST.LUCIENUCLEARPLANTUHIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS1CAEPBLSTATUSCOMPONENTSPAGE:26ZONENUMBER:2-038SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIOHASMESEC.XICATGYEXAMITEMHOMETHODPROCEDURENI0ONGTRSEMEI0EREMARKSCGMR**CALIBRATIOHBLOCK**I4-RC-101REF.DWG.HO.02-038119200RC-506-671NOZZLETOSAFE-EHD8-FPT85.40UT45UT45NDE3.3-46NDE5.4-75HDE5.4-76X---10/20/95-PTcomplete,10/24/95UTX---completeX---**UT-17*I-3-RC-309REF.DWG.HO.02-038120150RC-4300-9SpringSupportF-AVT-3NDE4.3-114F1.50X---11/20/95-VT-3completeI-3-RC-310REF.DWG.NO.02-038121550RC-4300-70SpringSupportF-AVT-3F1.50NDE4.3-1'13X---11/20/95-VT-3complete DATE:02/23/96REVISION:0UMP2ADISCHARGEHEADERPIPINGST~LUCIENUCLEARPLANI'NIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOMPONENTSPAGE:27ZONENUMBER:2-043SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIOHASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0OHGTRSEHEI0EREMARKSCGMR**CALIBRATIOHBLOCK*~I-6-SI-113REF.DHG.NO.02-043-D138650SI-2408-9RIGIDFRAMESUPPORTF-8VT-3F1~10HDE4.3-105X---,10/27/95-VT-3complete138800SI-113-Fll-5ELBOMTOELBNC-F-1PTHDE3.3-56C5.11UT45HDE5.4-92UT60HDE5.4-93X---'10/27/95-PTandUTcoaylete,rootX---geometry--X-ttUT38*%'138900SI-113-5-Ql-1ElbowtoPIpeC-F-1C5.11PTHDE3.3.56UT45HDE5.4-92UT60HDE5.4.93X---10/27/95-PTandUTcomplete,rootX---geometry--X-**UT-38**SI-113-FH-6PIPETOPENETRATION36C-F-1C5.11PTUT70UT45UT45UT60NDE3.3-56HDE5.4-90NDE5.4-91NDE5.4-92NDE5.4-93X---10/27/95-PTandUTcomplete,rootX---geometryX---X-----X-**UT-38**
Certificate of Authorization Connercial Service Date :
DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUHIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOMPONENTSINJECTIONPIPINGTOSITANK2A2PAGE:28ZONENUMBER:2-045SUMMARYEXAMINATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIOHBLOCK>>>>I-6-SI-113REF.DUG.NO.02-045168400S1-4200-322CINTEGRALATTACHMENTSCCPTC3.20HDE3.3-55X---10/26/95-PTcomplete,examined8integralattachments,noexaminationfranonesideduetosupportclamp
National Board Number for Unit:
Beach, Box 529100, Hiami, Florida 34957 (if required)
Florida 33152 Page 6 of  7 Two  inch valve V-2169, located in the charging system, was replaced during this outage. Baseline examinations were performed on the new piping welds.
: 15. Abstract of Corrective Measures                        Recommended        and Taken The  spring support found to have settings outside tolerances                                was reset. A follow-up visual examination confirmed no other recordable indications.
0 The loose      lock nut      and incomplete            thread engagement on one spring support were tightened.                 A  follow-up visual examination confirmed no other recordable indications.
Valve V-3217 was lapped to remove the wear areas noted. A new disk was also installed. A follow-up examination confirmed no other recordable indications.


DATE:02/23/96REVISION:0COOLINGHEATEXCHANGER2AST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOHPOHENTSPAGE:29ZONENUHBER:2-055SUHHARYEXAMINATIONAREANUMBERIDENTIFICATIONASHESEC.XICATGYEXAMITEHHOHE'THDDPROCEDURENI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK**REF.DUG.HO.02-0552092001-2701FLANGETOBODYC-AUT45NDE5.2-39C1~10UT60NDE5.2-40X---10/27/95-UTcomplete,limitedX---examinationduetonozzlesandflangeconfiguration**UT-52**2093001-2702BODYTOTUBESHEETC-AUT45C1.30UT60NDE5.2-39HDE5.2-40X---10/27/95-UTcomplete,limitedX---examinationduetonozzlesandtubesheetconfiguration+*UT-52*+2095001-2741-2PADTOVESSELC-BHTC2.31HDE2.2-30X---10/26/95-HTcceyiete01-2741-3PADTOVESSELCBMTC2.31HDE2.2-30X---10/26/95-HTcomplete2098001-2742-2PADTOVESSELC-BHTC2.31NDE2.2-30X---10/26/95-HTcomplete2099001-2742-3PAOTOVESSELC-BMTC2.31HDE2.2-30X---10/26/95-HTcomplete DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOHPONENTSEEDMATERTOSG2A1INSIDECONTAINMENTPAGE:30ZONENUHBER:2-067SUHHARYEXAMIHATIONAREANUHBERIDENTIFICATIONASHESEC.XICATGYEXAHITEHNOMETHODPROCEDURENI0ONGTRSEHEI0EREHARKSCGHR<<*CALIBRATIONBLOCK~*I-18-BF-51REF.DMG.NO.02-067252100BF-4007-6081INTEGRALATTACKHENTC-CHTC3.20NDE2.2-27X---10/16/95-HTcomplete,oneintegralattachmentexamined DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOHPONENTSEEDNATERTOSG281INSIDECONTAINHENTZONENUMBER:2-068SUMHARYEXAHINATIONAREANUHBERIDENTIFICATIONASHESEC.XlCATGY,EXAMITEHNOHETNODPROCEDURENI0ONGTRSENEI0EREMARKSC0HR**CALIBRATIONBLOCK*>>I-18-BF-52REF.DUG.NO.02-068255300BF-4006-6076INTEGRALATTACHHENTC-CHTC3.20NDE2.2-26X---'IO/16/95-MTcomplete DATE:02/23/96REVISION:0ST.LUCIEHUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)~CLASS2CAEPBLSTATUSCOMPONENTSPAGE:32EDHPSIDISCHARGEZONENUMBER:2-087SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDUREHI0ONGTRSEHEI0EREMARKSCGMR**CALIBRATIONBLOCK~*I-3-SI-179REF.DWG.NO.02-087-A361250SI-2416-352ANCHORF-8VT-3F1~10HDE4.3-99X---10/24/95-VT-3complete361300SI-2413-352INTEGRALATTACHMENTSC-CPTC3.20NDE3.3.54X-.-10/24/95-PTcompleteI-3-SI-179REF.DWG.HO.02-087-B364100SI-179-FW-910PipetoElbowC-F-1CS~21PTNDE3.3-53UT45NDE5.4.85UI'0NDE5.4.89X---10/24/95-PTcomplete,10/25/95-UTX---completeX---**3-SS-160..434.22**SI-179-8-SW-1ElbowtoPipeC-F-1PTHDE3.3-53C5.21UT45NDE5.4-85UT60HDE5.4-86X---10/24/95-PTcomplete,10/25/95UTX---complete,rootgeometry--X-**3-SS-160-.434-22*365200SI-179-FW-10PIPETOPENETRATIOH69C-F-1PTC5.21UT45UI'0UT60NDE3.3-53NDE5.4-85HDE5.4-87HDE5.4-88X---10/24/95-PTcomplete,10/25/95UTX---complete,insidesurfacegeometryX-----X-**3-SS-160-.434-22**I-2-SI-109REF.DWG.NO.02-087-C365300SI-109-F'W-1ReducertoPipeC-F-1C5.21PTUT45UT60UT70HDE3.3-52NDE5.4-82NDE5.4-83NDE5'-84X--.10/24/95-PTcomplete,10/25/95-UTX---complete,rootgeometryX-----X-**2-SS-160-.342-20**
, 3.
4.
Owner:
Plant:
Plant Owner NIS-1 Report (continued)
Florida Power and Light Company, P.O.
St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~
Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)
Florida 33152 Page 7 of 7 5.
: 6. National Board Number for Unit:
We certify that          a) the statements made in this report are correct,     b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.
Certificate of Authorization                  No.
Expiration Date Date:                                         Signed:
By CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of St. Lucie County, Florida, and employed by Arkwright Mutual Insurance Company of Norwood, Massachusetts, have inspected the components described in this Owner's Report during the period 10/9/95 to 1/4/96, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Data Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Insp ctor's Signature                                    National Board, State, u/     s~~
Province, and Endorsements Date:    ~ 5        4 7- 'P4


DATE:02/23/96REVISION:0EDHPSIDISCHARGEST.LUCIENUCLEARPLANTUNIT2INSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOMPONENTSPAGE:33ZONENUMBER:2-087SUMHARYEXAMIHATIONAREANUHBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDURENI0ONGTRSEN,EI0EREMARKSCGMR**CALIBRATIONBLOCK~*I-2-S1-109REF.DWG.NO.02-087-C365400Sl-109-SM-2PIPETOVALVEHCV-3647C-F-1PTC5.30NDE3.3-52X---10/24/95-PTcompleteI-2-SI-215REF.DWG.NO.02-087-J375600SI-215-FM-2ReducertoPipeC-F-1C5~21PTUT45UT60UT70NDE3.3-51NDE5.4-79NDE5.4-80NDE5.4-81X--X----XX10/24/95-PTcomplete,oneacceptableroundindication,10/25/95-UTcoapiete,rootgeometry**2-SS-160-.342-20**
St. Lucie Unit
DATE:02/23/96REVISION:0ST.LUCIENUCLEARPLANTUNIT2IHSERVICEINSPECTIONRESULTSFORTHESECONDINTERVAL,FIRSTPERIOD,SECONDOUTAGE(95RF)CLASS2CAEPBLSTATUSCOMPOHENTSNGPUMP2ADISCHARGETOAUXMPSIPAGE:34ZONENUMBER:2-088SUMMARYEXAMINATIONAREANUMBERIDENTIFICATIONASMESEC.XICATGYEXAMITEMNOMETHODPROCEDUREHI0ONGTRSEHEI0EREHARKSCGMR~*CALIBRATIOHBLOCK**I-2-CH-104REF.DWG.HO.02-088-B381625CH-104-FII.600PIPETOVALVEV-2169C.F.1PTC5.30QCRMM95-1817X---11/13/95-PTcomplete,examinationperformedbyQCpersonnel38'l660V-2169CHECKVALVEN/AN/A11/11/95-ValveHasreplaced381675CH-104-FM-601VALVEV.2169TOPIPEC-F-1PTC5.30QCRMM95-1817X---11/13/95-PTcomplete,examinationpe'rformedbyQCpersonnel St.LucieUnit2~~~DocketNo.50-389Fall1995RefuelingOutageL-96-72NIS-1ATTACHMENT21995EDDYCURRENTSUMMARYREPORT Page1of1FORMNISBBOWNERS'ATAREPORTFOREDDYCURRENTEXAMINATIONRESULTSAsrequiredbytheprovisionsoftheASMECODERULESEDDYCURRENTEXAMINATIONRESULTSPLANT:St.LucleUnit2EXAMINATIONDATES:NOVEMBER1,1995throughNOVEMBER9,1995STEAMGENERATORTOTALTUBESEXAMINED814220%-39%23140%100%TOTALINDICATIONSTUBESPLUGGEDASPREVENTIVEMAINTENANCETUBESPLUGGEDTHISOUTAGETOTALPLUGGEDTUBESINS/G2748213152209LOCATIONOFINDICATIONS(20%-100%)STEAMGENERATORAUBENDSDHBtoDCB222EGGCRATES1TO7H/LC/L26PARTIALSUPPORTS8AND9H/LC/L32TOPOFTUBESHEETTO41EGGCRATEH/LC/L10B14323Remarks:S/G'A':(1)ONETUBEPREVENTIVELYPLUGGEDDUETOMRPCEZIINDICATION.S/G'B'REVENTIVELYPLUGGEDTUBESINCLUDE:(2)THREETUBESPLUGGEDDUETOCORROSIONDAMAGEINTlSSLUDGEPILEREGIONFOURTUBESPLUGGEDFORFLAWSSHOWINGWEARPROGRESSIONATDIAGONALS(3)AND(1)VERTICALSTRAP(VS2)DATE:ZoPKPREPAREDBY:GECUENTCOORDINATORDATE'ATE'EVIEWEDBY:ISPECTIONSSUPRVISORREVIEWEDBY:S/8TENICALSECIALISTfcnnslUhiabbsO.~
  ~
0'L"')Pag)~I,g4<1q4jLn"l COMPONENT:STGgACUMULATIVEDISTRIBUTIONSUMMARYSTLUCIEUNITP210/95Page:1Date:11/16/95ExaminationDates:11/02/95thru11/09/95TotalNumberofTubesExamined8142TotalIndicationsBetween20%and39:Greaterthanorequalto40:2315TotalTubesPluggedasPreventiveMaintTotalTubesPlugged>=40%TotalTubesPluggedfromMRPCExaminationforTopofTubesheetIndicationTotalTubesPluggedThisOutage.........:LocationOfIndications204to100%07H+2.1toDHBDHB-3.0toDCB-3.1-3.0HotLegTSH-.5to01H-2.101H-2.0to07H+2.0ColdLeg1TSC-.5to01C-2.1201C-2.0to07C+2.0307C,+2.1toDCB-3.1222
        ~
2 Docket No. 50-389 Fall 1995 Refueling Outage NIS-j. ATTACHMENT j.
EXAMINATION TABLES


COMPONENT:STGgBCUMULATIVEDISTRIBUTIONSUMMARYST.LUCIEUNIT8210/95Page:1Date:11/16/95ExaminationDates:11/01/95thru11/09/95TotalNumberof.TubesExamined8213TotalIndicationsBetween204and39%Greaterthanorequalto4041524TotalTubesPluggedasPreventiveMaintTotalTubesPlugged)40o~~~~~~~~~~~~~~TotalTubesPluggedfromMRPCExaminationforTopofTubesheetIndicationsTotalTubesPluggedThisOutage*Note:Tube69-83waspluggedduetoabobbincoilresponseof4349TSH+0.6.Thistubealsoshowedapluggable"I"code(ASI)atthesamelocation.LocationOfIndications204to100>HotLegTSH-.5to01H-20101H-2.0to07H+2.007H+2.1toDHB-3.1ColdLeg6TSC-.5to01C-2.1201C-2.0to07C+2.0207C+2.1toDCB-3.1DHB-3.0toDCB-30143
DATE: 02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:     1 REVI S ION:       0                            INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS H  I  0 20NE NUHBER: 2-001                      ASHE                                    OHGT SEC. XI                                  RSEH SUMHARY EXAHIHAT ION AREA              CATGY    EXAH                          E  I 0 E REMARKS NUHBER    IDENT  IF I CAT IOH          ITEM NO  HETHOO      PROCEDURE          C G H R  **CALIBRATIOHBLOCK**
REF. DUG. NO. 02-001-002000    '101-121                      BA        UT1.5      NDE 5.12-1        X---    10/19/95 - UT complete, examination UPPER SHELL TO FLANGE MELO    B1.30    UT 5.7      NDE 5.12-2        X---    performed from the flange surface, UT 12.5    NDE 5.12.3        X.--    examination from the shell side will be performed at a later time
                                                                                          **UT-1, UT-8**
REF. DUG. No. 02-001      c 006300    S-01A  THRU S 54A            B-G  1    HT          HDE 2.2.31,32      X  - - - 04/25/95 - HT, VT-1, and  UT  complete, RPV STUDS 1 THRU 54          86.30    HT          NDE 2.2-35,36      X  - - - examined group "A" studs    thru 54 HT          NDE 2.2-37        X  - --                            1 VT.'I       NDE 4.1.34,36      X  - --
VT-1        HDE 4.1-38        X  - - - >>>>7-1.125-8-CS-52-SLC>>>>
UT.45      NDE 5.7.13,14      X UT-80      HDE 5.7-15,16      X UT-45      NDE 5.7-17,18      X-UT-80      NDE 5.7-19        X---
UT-45      NDE 5.7-20,21      X---
UT-80      NDE 5.7-22        X---
UT-45      HDE 5.7-23,24      X---
006500    N-01A  THRU N 54A            B-G.1    HT          HDE 2.2-31,33      - - - X 4/25/95 - MT and UT complete, examined RPV HUTS    1 THRU 54        86.30    HT          HDE 2.2.34,38      - - - X group >>A" nuts 1 thru 54, one acceptable UT-45      NDE 5.10-1        X - - -  linear indication UT-45      NDE 5.10-2         X -  --
UT-45      NDE 5.10-3         X - - - **UT-51**
006700    W-OIA THRU M-54A              B-G-1    VT-1        NDE 4.1-35        X  - - - 4/25/95 - VT-'I complete, examined group RPV IIASHERS    1 THRU 54    86.50    VT-1        HDE 4.1-37        - - - X eA" washers 1 thru 54, acceptable VT-1        HDE 4.1-39        - - - X corrosion and pitting 006900    FL-01  THRU    FL-54        B-G-1    UT 0        HDE 5.12-4        X  . - - 10/19/95 -  UT complete, examination THREADS IH RPV FLANGE        86.40                                            performed from the seal surface
                                                                                          **UT 8**


COHPONENT:STGfIADESCRIPTION:20%TO100%INDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDate:11/16/95Time:08:38:52IIRowl+---II891Ias/I901I611I921IIIII881IIIII981I811IIIIIII961III981110slI921I961Is11I88111011I11IazlIIIII31I751I481II11z61I781IIII11261I49111231IExtentLinlLeglReqlTst/HotelReel---I---I--I-------I-211HITECITECPSIAH070221HITEGITEcIAH070241HITECITECPSIAH070IHITECITECPSIAHOS261HITECITECPSIAH093IHITECITECPSIAH093IHITECITECPSIAH093281HITECITECPLIAH066IHITECITECPCIAH066HITECITECPCIAH066281HITECITECPSIAH089291HITECITECPSIAH089IHITECITECPSIAH089IHITECITECPSIAH089IHITECITECPSIAH089301HITECITECPCIAH066IHITECITECPCIAH066301HITECITECPSIAH089331HITECITECPSIAH089341HITECITECPCIAH066341HITECITECPSIAH066351HITECITECPCIAH087361HITEGITECPSIAH066371HITECITECPSIAH089391CITEHITEHPCIAC099441CITEHITEHPLIAC048471HITECITECPLIAH068IHITECITECPCIAH068IHITECITECPCIAH068491CITEHITEHPSIAC099491HITECITECPCIAH103491CITEHITEHPSIAC05301CITEHITEHPSIAC002501HITECITECPSIAH068IHITECITECPSIAH068OlKITECITECPSIAH091521CITEHITEHPSIAC048521CITEHITEHPSIAC053ICITEHITEHPSIAC053ICITEHITEHPGIAC053541HITECITECPSIAH091551CITEHITEHIAC003551CITEHITEHPSIAC047ProbeIILocationI.7-7-.6.9.7-7-1.2-.8.81.01'.4-.4-7-.6-.91.81.3.8-.8-.6.9-.81~1-3-.81.0-.6~9-.8-7.0-.6.9-9-1.0IA-580.H/ULCIVS2IA-580.H/ULCIVS3IA-580.H/ULCIVS3IA-580-M/ULCIVS4IA-580-H/ULCIVS3IA-580.M/ULCIVS4IA-580-M/ULC105CIA-580-H/ULCIVS3IA-580-H/ULCIVS4IA-580-M/ULCIVS4IA80H/ULCIVSIA-580-M/ULCIVS3IA-580.M/ULCIVS3IA-580.H/ULCIVS3IA-580-H/ULCIVS4IA-580H/ULCIVS2IA-580-H/ULCIVS4IA-580H/ULCIV2IA-580-H/ULCIVS2IA-580.H/ULCIVS4IA-580.H/ULCIVS2IA-580-H/ULCIVS3IA-580.H/ULCIVS4IA-580.M/ULCIVS3IA-560-SF/RHITSHIA-580-M/ULCIVS2IA-580-H/ULCIVS2IA-580-M/ULCIVS3IA-580-M/ULCIVS4IA-560-SF/RH102CIA-580.M/ULCIVS3IA-580.H/ULCIVS3IA-580-H/ULCIVS3IA-580.H/ULCIVS1IA-580.M/ULCIVS2IA-580-M/ULCIVS1IA-580-H/ULCIVS4IA80M/ULCIVS2IA-580.M/ULCIVS3IA8H/ULCIVSIA-580.H/ULCIVS1IA-580.H/ULCIVS3IA-580.M/ULCIVS1I-I-10/95IvoltslDeglchII711.slI61I61I.61I.71II21IPzlII21IIzlI>>lIIzl221211221211I231I1.21132111271~61.sl.71.81.81.71.71.sl.sl.51.sl1.21.71IP21231IIzl201II21231II21z61IP21301IP21zslIPzl231IP21z41IP21z11I>>I201II21zolIPzlzzlII21311IP21zslIIzl221.91139111211~41133111301~91~slF01~91.71.61~sl.sl1.01~slhei~sl1.41~91.sl.81~41Iliz13slli21zollizl291IP21zelII21221IP21241IP21201II21221II21zzlIIzl291IP21zslli21311II21zolIr21311IP21241II21zslIP21211IIzl201II-I--%IDifflLocationN/AlvoltslDeglchI%IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII-I COMPONENT:STGfIADESCRIPTION:20KTo100'NDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDateTime2:11/16/95:08:38:56IIRowlLinl+III131I55II89I57II9sl5rlI129I57II92I58IIIII96I58II93I59II12rl59IIrelsalIIII96IsalI39I63II93I6311133I63II135I63IIIIIIII94I64IIIII47IsslIIII34IselIeelselI35I69II37I69IIIII42IrolI44IrolI82I7olIeelrolI136IrolIIII39I71II41I71II43I71II45I71IIIII79I71II38IralIIII40Iral'---I--I-IExtentLeglReqlTst/---I--I-CITEHITEHCITEHITEHCITEHITEHCITEKITEHCITEHITEHCITEHITEHCITEKITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEH--I--I----IkotelReelIIILocationIProbeIA-580M/ULCIDCBIA-SBO.M/ULCIVS2IA-SSO.M/ULCIVS2IA-580.M/ULCIDCTIA-580.M/ULCIVS4IA-580.M/ULCIVS4IA-580.M/ULCIVS3IA-580.M/ULCIVS4IA580M/ULCIVS1IA-580M/ULCIVS2IA-580-M/ULCIVS3IA-580.M/ULCIVS3IA-580-M/ULCIVS3SCIAC051PSIAC006PLIAC053PSIAC047PSIAC053PSIAC053PSIAC053PSIAC048PSIAC047PSIAC052PSIAC052PCIAC059.0.9-.8.01.0~2-.8-.61.01.0.9-.7IAc003-1.0ScIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580M/ULCIA-580M/ULCIA580.M/ULCIA-580.M/ULCIA-580.M/ULCIA-580M/ULCIA-SBO.M/ULCIA-580.M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580M/ULCIA-580.M/ULCIA-580-M/ULCIA-580M/ULCIA-SBD.M/ULcIA-580-M/ULCIA-seo-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580M/ULCIA-580M/ULCIA-580M/ULCIA-580M/ULCIlvsalvsiI09HIVS1IvsiIvsaPSIACPSIACIAC045islAco45PSIAC045PSIAC052PSIAC052sclAcoo3PSIAC039PSIAC039PCIAC004PSIAC032PCIAC003PSIAC003PSIAC003-1~1.e.9-.8.9.9Ivs3.9lvs3lvsaIvs4IDHBlvsaIDCBIDHB-.9-.9-.9.0-.9.0-3I07c25.oGNPLIAC060IDCBIocgIvs3IvsaIVS1Ivs3~7~0-1.0-7-.8-7PSIAcosoPSIAC032PSIAC032PSIACPSIAC045PSIAC069PSIAC069PSIAC069PSIAC069PSIAC069PSIAC039IDCB.0IDCB.0IDCBIDC8IDCBIVS2.0.0~0-7IDHBGYPLIAC060PSIAC060PLIAC060---I-~0IDCB1.0IDHB.0.5I.7I~sl~5I.sl.Sl.sl~5II~5~rl.7I.5I1.1I.9I~9l.7I1.5I.Sla.ol1.11.5I.7I.sl1.1I.sl.sl.7I.9I~7I.Sl.7I1.olIial21IIialaolIial24IIPal3olIial34Ilialas/lial24Ilial23Ilialas)Iial23IIPalaolIP2I22IIialaolIial23IIialaalIial31IIPalaolIIal32IIialaalIralaalIPalaalIPalaalIialaallial23IIialaelIPalaolIPal32IIPal36IIPal24IIPalaalIialaelIialaollialaolIialaolIial21IIial23IIPalaollial31IIPalarllial33IIII10/95IIIvoltslDeglchIXIDiffl----I---I---I.I.slIial21ILocationIIIIIIIIIIIIN/AIvoltsloeglchIXI COMPONENT:STGO'A:20KTO100KDESCRIPTIONINDICATIOHS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDateTime3:11/16/95:08:38:56I(Row(+-III42(III82((88((126((43(II(491I55(175(11351IIII(421(43(III451III441(S1(I531II1571(73(II(so((72((961I49(IIIIII(S3(Isa(IIINote(Reel-I-GNPLIAC060GNPLIAC060IAC060PSIAC032PSIAC032PCIAC042PSIAC045PSIAC069PSIAC069PSIAC069PSIAC069PSIAC039PSIAC045PSIAC045PSIAC045GYPLIAC060PSIAC060PSIAC032PCIAC069PCIAC069PLIAC069PSIAC069PSIAC045GNPL(AC060PSIAC069PSIAC069PSIAC069PSIAC069PSIAC069PSIAC039PSIAC039GNPLIAC060SSIAC038Ps(Aco61PS(AC069PS(AC069PS(AC069PSIAC069PS(AC069PSIAC069GHPL(AC062GYPLIAC062PSIAC062IICITEHITEH72(CITEHITEHIcITEHITEH21CITEHITEH721CITEHITEH721cITEHITEH721CITEHITEH731CITEHITEHICITEHITEH731CITEHITEH73(CITEH(TEH73(CITEHITEH731cITEHITEH(C(TEH(TEHIcITEHITEH74(cITEHITEHICITEHITEH741CITEHITEHICITEHITEHIcITEHITEH75(C(TEHITEHICITEHITEH751CITEHITEH761cITEHITEH771cITEHITEH77(CITEHITEH77(C(TEH(TEHICITEN(TEH77(C(TEH(TEH771CITEHITEHICITEHITEH781CITEHITEH781CITEHITEH781CITEHITEH791CITEHITEHIC(TEH(TEHIcITEHITEHICITEHITEH79(CITEHITEH791CITEHITEH8O(C(TEH(TEHICITEHITEH801CITEHITEH--I--I-I(S4(+---(-(ExtentLin(LeglReqlTst/IIIProbeILocation(DCTIDHBIDCTIVS3Ivs3109HIVS1IDHT(Dce(BeeIDCB(VS3(VS1IVS3Ivs4IDHBIDCB(vsaIA-580-M/ULCIA-580-M/ULCIA-580.M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULC(A-580-M/ULCIA-580-M/ULC(A-580.M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIDHBIA-580-M/ULCIDCTIA-580-M/ULCIDHTIA-580.M/ULCIDCTIA-580M/ULCIVS1IA-580-M/ULCIDHBIA-580M/ULcIDGTIA80M/ULCICTIA-580-M/ULCIDHBIA-580-M/ULCIDCTIA-580-M/ULCIDCTIA-580-M/ULCIVS2IA-580.M/ULCIVS2IA-580-M/ULCIDHBIA-580.M/ULCIVS4IA80M/ULCIVS3IA-580M/ULCIDHTIA580M/ULCIV3(A-580.M/ULC(VS3IA-580-M/ULCIDCTIA-580.M/ULCIDHT(A-580-M/ULC(DCBIA-580-M/ULCIDHTIA-580-M/ULCIDCB(A-580-M/ULC(DCT-I---------I-.0~0.0-.81.0~1.8.0~0.0.0~9.8.9-.9.0.0-~8.0.0.0.0.9.0.0.0.0~0.0-.7.8.0-.5-.9.0-.9-2~0.0.0.0.0.01.11~7(IP2(36((I2(24((I2(22((I2(221.4113311(24(.6(.6(.61~71.9(.61.912.611.212.3(1.21~91~611.2(a.o(2.111.61.8(1.o(1.011.11~9(2.21F811.S(.711.211.711.7(I(I2(ao((p2(ao(IP2(ao(IP2(as)(I2(ao((I2(22((I2(28(IP2(21((I2(26((I2(s3((P2(311(I2(311(I2(321(I2(34(IIas(Ii2(23((I2(21((I2(37(IP2(32((I2(33((I2(3o(IP2(22(II2(241(I2(211(p2(22(IPal3s(II2(3o((I2(as((I2(29(II21331II2(22(II2(291,,IP21211Iia(261(P214s((p2(46(IP21261I-I-I--I----I-10/95II(volts(oeg(ch(X(Diff(IP2(3s(N/ALocationlvoitsloeg(chIXI----------I----I.I--I"+IIIIII---I-'
DATE:   02/23/96                              ST. LUCIE NUCLEAR PLANT UNIT 2                                     PAGE:   2 REVISION:       0                         INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
COMPONENT:STGIIA:20/.To100KDESCRIPTIONINDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDateTime4:11/16/95:08:38:56IIRoM)+-I62)4IIIIIs3)IIIss)I73)I501)6o))541I49)II)S1)IIIss)~/57/I541)56))se))92)IIII)14o)I491)S1)II)SS)IIII)s91I931)so)I941I47))S3)II)951I451II)471+---I-INote(ReelIExtentLin)Leg)Req)Tst/IIII-GNPLIAC062801CITEHITEH81)CITEH)TEH)C)TEH)TEHIcITEHITEH811CITEHITEHIcITEH)TEH811CITEHITEHe1)c)TEH)TEH821CITEHITEH821cITEHITEH841CITEHITEH851cITEHITEHICITEHITEH851cITEHITEHIcITEHITEH851CITEHITEH851CITEKITEH851cITEHITEK861CITEHITEH861CITEHITEH861CITEHITEK861CITEHITEH861CITEHITEKIcITEHITEKIcITEHITEK861CITEHITEH871CITEHITEH871CITEHITEHIcITEHITEH87)CITEH)TEHIcITEKITEHIcITEHITEH871cITEHITEHe71c)TEH)TEH881CITEHITEH88)CITEHITEH891CITEHITEH891CITEHITEHIcITEHITEH891CITEHITEH911cITEHITEHICITEHITEH911C)TEH)TEH--I---I-IPSIAC071PL)AC071PLIAC071PSIAC071PSIAC071PSIAC071IAC041PSIAC062PCIAC062PSIAC058PSIAC067GNPLIAC067PSIAC067PSIAC067PSIAC067PSIAC067PSIAC041GYPLIAC058PCIAC058-PSIAC058PSIAC058PSIAC061PSIAC061PSIAC061PSIAC045PLIAC067PSIAC067PSIAC067PSIAC067PSIAC067PSIAC067PSIAC067PS)ACPs)AcosePC)ACGYPLIAC067PSIAC067PSIAC067PLIAC061PSIAC067PSIAC067PSIAC067IIProbe)LoI.-I-.IA-SBO.M/ULCIDCB)A-580-H/ULC)OHBIA580-H/ULC)VS3IA-580-H/ULcIDGTIA.580-M/ULC)oHBIA-seo-M/ULCIDGTIA-580-H/ULCIDCTIA-580-H/ULC103CIA-580-M/ULCIDCBIA-580-H/ULCIDHB,IA-580-M/ULCIDCTIA-580-M/ULCIDHBIA-580-M/ULCIDCBIA-580-M/ULCIDHB)A-580-M/ULC)DCBIA-580M/ULcIDCBIA-580-M/ULCIDCBIA-580-H/ULCIVS4IA-580-M/ULCIDHBIA-580.M/ULCIVS3IA-580H/ULCIDCBIA-580.M/ULCIDCBIA.580-M/ULCIVS2IA-580-H/ULCIVS3IA-580-H/ULCIVS4IA-580-H/ULcIDGTIA-580.H/ULCIDCTIA-580-H/ULCIDHBIA-580.H/ULCIDCTIA-580-H/ULCIDHBIA-580-H/ULCIVS3)A-580-H/ULcIDGTIA-580-M/ULcIDHBIA-580-H/ULCIVS2)A-SBO-H/ULC)OCB)A-580.H/ULC)VS4)A-580.H/ULC)DHBIA-580M/ULCIDHBIA-580-H/ULcIDGTIA-580-H/ULCIVS4IA-580-H/ULCIDHBIA-580-H/ULCIDCTIA-580-H/ULCIDHB-I---'---------I-N/AI)volts)oeg)ch)xI10/95II)Volts)oeg)ch)X)Diff)Locationca'tion.-"---I----.I---II--I----I-----------I-----I~oI-9)I>>I34)III---)---+)I2)21).0IIIIII1.81Ii2)3o)2.71Ii213611.o)Ii2122)1.s)II2)ar)2.11IP2)32).41136111251-.8.0.0.0.0-.6~0.0~0.0.0.0)p2)27)IP2)28))I21341)p2)3o))I2)371)I2)24)IIII'II~911.7)2.7)1.11Ii21241)P2133)1~O)2.11.4)1.51.S).8).61.8)1.61.611'1.0~0I>>I261I.0)I2)ao)-1.0)I2)43)~1Ir2)as))I2)3o))r2)as))I2)23)-1.0~0.0.7II2)32))I2)21))p2)'34))I2)36)Ir2)as)IP21321)I21as)-.7-.9.02.51.0)'.1)1.2).0.0.0.7)1~11.8).S).S))I2)ao)II21as))I21as/)I2)221)p2)as))p2)21))P2148))p2)as/Ir2)ao)IP2)as/Ir2)261IPa)as/.8.0.0.8.0-.9~0.0.01.2.0.0.0.71.611.311.31.7)III21ao)-I---I---I---I-IIIII-I----II--I-'
CLASS  1 CAEPBL STATUS COHPONENTS Generator  2A Primer  Side N I   0 ZONE NUMBER:  2-003                ASHE                                    ONGT SEC. XI                                  RSEH SUHHARY EXAHINATION AREA            CATGY    EXAH                          E  I 0 E REMARKS NUMBER  IDENTIFICATION            ITEM NO  METHOD      PROCEDURE          C G H R  **CALIBRATIONBLOCK*"
COMPONENT:STGfIA:20KTO100/eDESCRIPTIONINDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDateTime~5:11/16/95:08:38:56IExtentLeglReqlTst/---I-I----IIRowlLinl'---I---I1139l91II45I93II97I93II49I9slIIII94I96II4rl9rlIIIIs3I9?lI13sl9?lI134I98II138I98II45I99II4ol1oolI46I100II48I100II54I1oolI31I1oilI34I102II134I1oalI91I1o3II95I105II96I108IIIII101I109IIaal11olI123I113IIIIIIII4?I11slIIII127I117II84I12olI94I12olI1oal12olI126I12olIs3I12rlI91I12?lI9?I12?lIs4I128II8?I129II---I-CITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHHITECITECHITECITECHITECITECHITECITECHITECITECHITECITECCITEHITEHHITECITECCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHHITECITECHITECITECCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHcITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEH--I---I--IHotelReel----IPSIAC045PSIAC067PSIAC056PLIAC067PSIAC067PBIAc056PLIAC067PBIAC067IAC067IslAco45PCIAC045IslAco45PSIAH082PSIAH082PCIAH105PSIAH105PCIAH105PCIAH107PCIAC030PCIAH105PCIAC045PLIAC069PCIAC063PSIAC024PSIAC024PSIAC023SCIAC029PSIAC018IAC018PSIAC018PSIAH084PSIAH084PSIAC023PSIAC015PSIAC023PSIAC017PCIAC035IAC017PSIAC012PCIAC018PsIAC017PSIAC011SCIAC016----I-10/95lvoltslDeglchI-I-----I---I--II1.alIIalIxIDif---I--aslaol22I26Iasl26I26I21I29I21Iaol22I22I21I24I22I26I21Ias/22I21Iarl21Iaolaol22I23Iaol22I21IProbeILocationIA80H/ULCIDHTIA-580.M/ULCIDCBIA-580-H/ULCIVS3IA-SSO.H/ULCIVS3IA-580M/ULCIDCTIA-580-M/ULCIVS2IA-SBO.H/ULcIvs3IA-580M/ULCIDCBIA-580-M/ULcI04cIA-580.H/ULcIVS3IA-580.H/ULCIVS3IA-580-H/ULCIDHTIA-580.M/ULCIDCBIA-580-H/ULCIV3IA-580.H/ULCIVS3IA-580-M/ULCIVS3IA-580.H/ULCIDCBIA-580-H/ULCIVS3IA-580-H/ULcIDGTIA-580-M/ULCIVS3IA-580-H/ULCIDCTIA-580-H/ULCIVS4IA-580-H/ULCIVS3IA-580-H/ULCIVS2IA-580-H/ULCIVS3"IA-580-H/ULCIVS3IA-580-H/ULCI03CIA-580.M/ULCIVS1IA-580.H/ULCIVS3IA-SSO.H/ULCIVS4IA-580H/ULCIVSIA-580-H/ULCIVS3IA-580-M/ULCIVS1IA-580-M/ULCIVS4.0.0.9-7~0~?.8.026.2.8-3.0~0.8-.8-7.~0~7.8.0~9~9-.9-.91.012.5-.8~7-.9-.81.0.8.9~rl.4I1.2I.5I.SllpalIIalIIalIpallpalIral.SI134I.6I.sl1.6I.sl.Sl.6I.6I.sl.Sl.6I.5I.7I.slI>>lIralI>>lIIalIIalIIalIIalI>>II>>llpalI>>llpalIIalIIalI>>II>>I.4I.6I.7I.sl.6I.6IIpalI>>lIIalI>>lI>>IlpalIIallvsalvs3IOSHloseIVS3lvsaIvs3IVS3.8-.8-1.3.8.8-.9.8.8IA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-H/ULCIA-580-M/ULCIA-580-M/ULCIA.580-H/ULCIA-580-H/ULCIA58H/ULcI-IIal26IIIalaolIIalaolIIalaallialarlIIalas/IIal24IIIalaalIpalaolIII-.sl1.ol.6I.Sl.5I.7I.6I~4IIIvs3-.8II-------------I-flLocationIIIIIN/AlvoltsloeglChIIIIIIIIIIxI+IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII COMPONENT:STG&#xb9;ADESCRIPTION:20KTO100KIIExtentIRoMILin(Leg(ReqlTst/Note(ReelIPSIAC016PSIAC023IsIacoizPsIAC014PsIAC013PsIAC013PSIAC013PsIAC013--I--I-IIIIIcITEHITEHI9311311CITEHITEHI5711331CITEHITEHI9711331CITEHITEHI9611341cITEHITEHIIIcITEHITEH(96('138(CITEHITEHIIIcITEHITEHI911391CITEHITEHPsIAC014I97(1391cITEHITEHI481140(CITEHITEHI111411cITEHITEHI85(141(cITEHITEHI8711431cITEHITEHIIIcITEHITEHPSIAC013PSIAC009PCIAC033PSIAC013IAC014PCIAC014I4911471cITEHITEKPSIAC012I5611521CITEHITEHI7411541CITEHITEHI5711551cITEHITEH(51(157(CITEHITEHPSIAC014PSIAC013PSIAC013PSIAC014I311591CITEHITEHPSIAC033+IIIIINumberofRECORDS,SelectedfromCNumberofTUBESSelectedfromCurProbeIIA-580M/ULCIA-580.M/ULCIA-580-M/ULCIA-580M/ULCIA-580.M/ULCIA-580.M/ULCIA-580.M/ULc(A-580M/ULCIA-580.M/ULC(A-580-M/ULCIA-580.M/ULCIA-560-SF/RMIA-580M/ULCIA-580.M/ULCIA-580-M/ULCIA-580-M/ULC(A-580-M/ULCIA-580.M/ULCIA-580-M/ULC(a-580-M/ULCIA-560SF/RMIurrentOutagerentOutage:INDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95ILocationI'0/95IIlvolts(DeglchII(Diff(I--I--I--I-II141IP2(36(I-91IP2126(.6(IP2124(I.71IP2127(I~4(IP2(20(IF51IP2(21(.6(li21zzlI11(IP2(27(I~4(IP2(21(as(IP2(24(.slIp2122(I7(142(1(20(6(Ipzl21(I4(IP2(211(IslIP2(24(Ilvs3IVS2.9IVS3-.6lvszlvsz.8lvs3.7lvszlvs3(VS2IVS2-1.2IVS3.8(01H24'IVS3.8IVS2-1~1IVS3.4IDCB.O.6(II21zzlli2122(.51133111301.6(Ip2(z1((I2(28(.51128111351----.I---I--I--I----IIvs3-1~0I105H26.1IIVS3-.7lvs3103c5.8II------------I236177IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII.IIIIIpage:6Date:11/16/95Time:08:38:56+N/AILocationlvoltslDeglchIXI---I---+
REF. D'IJG. NO. 02-003 015700  TUBE BUNDLE                B-0       ECT        NDE 1.3            - - - X 11/9/95 - 8,142 tubes examined, 236 U-TUBES                    B16.20                                           indications, five tube plugged this outage due to HRPC EZI indications


~~COMPONENT:STGffeDESCRiPTION:20KTO100KlNDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95Page:1Date:11/16/95Tine:08:40:03IIRo~l+-II54lIBrlI96lIIII4slI94II96II98II1oilIioolI>>II>>IIIIIIIIII471I96II81II>>IIII>>IIII43II68IIsrlI1solIiszlI49II59II137II34lIII36II39IIotelReel--I-PCIBC092iSIBH1osPSIBH103isleH1osPSIBH103PCIBH103PSIBC105PCIBH086PSIBH103PSIBH086IBC106PSIBC096PCIBC096PCIBC096PCIBC096PCIBC096PCIBC096PCIBC096NPLIBC096PCIBC096PCIBC096IBC107PSIBC098PSIBC109PCIBC127PCIBC127PCIBC098PCIBC098PSIBC101PSIBC019PSIBC018SCIBC081PslecO64PslecO64PSIBC017PGIBc077IBC019PCIBC075PSIBC018NPLIBC018PSIBC018PSIBC019PSIBC08222ICITEHITEH23IHIIECIIEC24IHITECITECIHIIEGITECIHITECITEGIHITECITEC25IcITEHITEH26IHITEGITEC26IHITECITEC26IHITECITEC27ICITEGITEH28ICITEHIIEH29ICITEHITEH29ICITEHITEHICITEKITEHIcITEHITEHIcITEHITEHIcITEHIIEHICITEHITEHGIcITEHITEHICITEHITEH33ICITEHIIEH34ICITEHITEH41ICITEHITEH41ICITEHITEHICITEHITEH41ICITEHITEHICITEHITEH47ICITEHITEH50IcITEHITEH51ICITEHITEH55IcIIEHIIEH56ICITEHITEH58ICITEHITEH59ICITEHITEH59ICITEHITEH65IcITEHITEH67ICITEHITEH68ICITEHITEHIcITEHITEHG68ICITEHITEH69ICITEHITEH70ICITEHITEH+-.-I"-I.--I-IIExtentLinlLeglReqlTst/NI--I-I-----IProbeILoI-I----IA-580-M/ULCIVS3IA-580-M/ULCIVS2IA.580.M/ULCI07HIA-580-H/ULCIOBHIA-580-M/ULCIVS4IA80H/ULCIDCBIA-580-M/ULCIVS3IA-580-H/ULCIV2IA-580-H/ULCIVS4IA-580-M/ULCIDCTIA-580-H/ULCIDCTIA-580-M/ULCIDCTIA-580-M/ULCIDCTIA-580-M/ULCIDHBIA-580-M/ULCIVS1IA-580-M/ULCIVS1IA-580-M/ULCIVS2IA-580-M/ULCIVS3IA-580-M/ULCIVS3IA-580-M/ULCIVS4IA580H/ULCIV4IA-580-M/ULCI02CIA580M/ULCIV2IA-580.H/ULcIvs3IA-560-SF/RMIVS2IA-560-SF/RHIVS4IA-580.H/ULCIVS2IA-580.M/ULCIVS4IA-580-M/ULCIVS3IA-580-H/ULCIVS3IA-580.H/ULCIVS3IA-seo-H/ULcIoceIA-580.M/ULCIDCTIA-580M/ULCIVS1IA-SBO.H/ULCIVS3IA-580.H/ULCIDCTIA-580.H/ULCI06HIA-580-H/ULCIDHTIA-580-M/ULCIDCTIA-580-H/ULCIDCBIA-580-H/ULCIVS3IA-580-H/ULCIVS3IIA580.H/ULCIVS3-I------------I-cation.7~2-.9.0-.6-.8.0.0~0.0-7.81.0-.91.0.9-1.032.9-7-.81.0-1.0.7-.5-1.0-1.1-.9.0.0-.8-7.018.3.0.0.0.9-.9-.810/95IVoltsl.7I1.1I.6I.sl.9I.7I.3I.3I.2I~4I~2I~sl~sl1.ol.5I.6I~4I~4I.6I.6I1.ol.Bl.7I.rl1.01.Bl.7I1.ol.5I1.1IIIDeglchIIIoifflIII-IlialaelIialzollralaslIizl21IlralaslIizlzsllralas/IizlaolIial21IIizl29Ilrzl24IIPal34IlralaslIrzlaslIrzl26IIPalzilIralarlIral21IIral36IIPzlas/IPalasl14ol1Izillrzlz6IlralaslIPalzillrzlazllrzl24Ilrzl24IIrzlzalIPzlas/IPalsalIPalz4IIPalsellral29IIPzl24IIPzlsol138I1I24IIPalaolIPal31IIral36IIPzlarllrzlaslIPzl31ILocationN/AIVoltslIDeglchIx,IIII'IIIIIII 0
DATE:   02/23/96                                      ST. LUCIE NUCLEAR PLANT UNIT 2                                     PAGE:     3 REVISION:       0                                 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
COMPONENT:STGIIB:20KTo100/oDESCRIPTIONINDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95PageDateTime2:11/16/95:08:40:06I(Row(LIn(+II(4s(ro((35(71(IIII451711(97(r1(I4s(ra(I44(76(I521761I56(r6(I47(77((55(77(I44(rs(IIIIIII46(rs(IIIIIII48(78(I50(78(III(52(78(I,III88(78(I96(rs(I51(79((57(79(Isa(so(IIII49(81(IIII98(82(I49(83(IIII51(83(I691831I71(83((73(83(Isr(83(I891831I48(84((So(84((88(84(I511851'.l---lINote(Reel-I-Is(ecosaIC(BCO93Pc(BC093Ic(ecO93ps(ec074PLIBCOBPLIBC082PLIBC082PL(BC082PSIBC093PSIBC093PSIBC082ps(ecosaPL(ecosaGNPLIBC082GNPLIBC082PSIBC082PSIBC082PSIBC082GNPLIBC082Is(ecosaPs(scosaPLIBC054PSIBC087PSIBC093GMPLIBC093PLIBC082PSIBC082GHPL(BC093PSIBC093PCIBC076PBIBC093PSIBC093PCIBC093PLIBC067PSIBC067Ps(ecO67ps(eco67PSIBC067PclecoeoPSIBC080ps(ecO54GNPLIBC091ICITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEH(TEHCITEH(TEHCITEHITEHcITEN(TENCITEH(TEHCITEHITEHC(TEHITEHCITEH(TEHCITEHITEHCITEKITEHCITEHITEHCITEHITEHCITEHITEHCITEKITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEH-I-I(ExtentLeg(Req(Tst/IIIProbe(LoI-IIA-580.H/ULCIVS3(A-580-H/ULC(DCBIA-580-H/ULCIDCBIA-580-H/ULCIDCTIA-580-M/ULCIVS4IA-580-H/ULCIVS3IA580-H/ULCIDHBIA-580-M/ULCIVS3(A-580.H/ULCIVS3IA-580H/ULcIDHBIA-SBO.H/ULCIDCB(A-580-M/ULCIDHBIA-580.H/ULCIDCTIA-580-H/ULCIDCBIA-580-M/ULCIVS3IA-580-H/ULCIVS3IA-580-H/ULCIDCBIA-580-M/ULCIDCBIA-580-M/ULCIDHBIA-580-M/ULCIDCTIA-580-M/ULCIVS3IA-580-M/ULCIDCTIA-580-M/ULCIVS2(A-580.M/ULCIVS2IA-SBO.M/ULC(DceIA-580.H/ULCIDCTIA-580M/ULCIDHBIA-580.H/ULC(DCTIA-580-H/ULCIDHTIA-580H/ULcIoceIA-580.H/ULCIVS3IA-SBO.H/ULCIDHTIA8H/ULCIDCTIA-580-4/ULcIDGBIA-580.M/ULCITSHIA80M/ULCITSH(A-580-M/ULCITSHIA-580H/ULCIVS3IA-SBO.F/ULCIvs3IA-580-M/ULCIDCT(A-580-M/ULC(DGTIA-580.H/ULCIVS2IA-580.H/ULCIDCB-I-------I10/95II(Volts(Deg(chIX(Diff(cation----I---II--.I--I--I-I-4(IP2(201I-72(23(2(23(alas(.5(.5(.8(.5(1.2(.6(.9(.0.02(3o(-.9212112(32(2(as(2(22(2(24(2(3o(-.9.0.61.0IP.0.0.9(.8(~rl1.8(~5(2(as(212512(24(2(39(2(35(2(21(2(34(2(26(2(39(1.3-7.0-71.01.0IPIP(I.8(1.8(.6(.8(.9(.6(1.9(.7-.62(31(2(23(2(24(2(as(-.6-.6.7-.82(23(2(45(2(36(2(as/.0.01.5(.6(~8-.62(33(2(24(2(23(2(34(2(29(2(ao(1(23(-.2.6(4(.8(.01.0.0.041IP1.411221~411411.811371~41IP1.o(.91IP1.O(.8(.0.61.3.7-9.9.0.0.0.01(as(2(ao(213212(32(2(33(al241I1(4s(-II----I-2.2(II--IIIIIIIIIIIII,IIIIIII-I--'/ALocation(Volts(Deg(chIX(
CLASS  1 CAEPBL STATUS COMPONENTS Generator  2B Primer          Side N 0 ZONE NUMBER: 2-004                        ASME                                    ONGT SEC. XI                                  RSEN
+(0
~jCOMPONENT:STGge:20KTo100KDESCRIPTIONINDICATIONS/TRENDINGREPORTPSL-2OUTAGE:10/95pageDateTime3:11/16/95:08:40:06I(RoN]tin]+II]sr]ssl]46]S6]IIII54]s6]]ss]86]]47]sr]I55I87I]73]sr]I48IBSIIII]sa]as/]s6]ss]]62]Ss]III]72]as(I51I89II44I9o(I4S(91]IIIIIIIIIIIIIII]42]92]]46]92]Is4]92]I6o]92]]43]93]]4zl94]I46194IIII]50]94](sa(94]I94I96II71]97]]93]97]]34]98(]3r]99]I94I100IIIII93I101IIExtentLeg]Req]Tst/IICITEHITEHCITEN(TEHCITEHITEHCITEHITEHCITEHITEHCITEH]TEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHC]TEH]TEHC]TEH(TEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHC]TEH]TEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHC(TEH(TEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEH-I---I---.INote)Reel-I-PSIBC091PslecosoPS]BCOSOPc]BCOSOPSIBC056PCIBC091PCIBC091PSIBC067PSIBCOSOPSIBCOSOIs]ecOSOGNPLIBcosoPCIBC080PCIBCOBOGNPL]BC056PCIBC091GNPL]BC080GNPLIBC091PS]BC091PSIBC091PSIBC091PSIBC091PSIBC091PSIBC058Is(ecosoGNPLIBCOSOps]ecosoPSIBCOSOPCIBC091ps]ecosoPL]BC080PSIBCOSOPCIBC080PSIBC080PSIBC078PSIBC073PSIBC078PSIBC097PLIBC084Ps]Bc078PSIBC078PSIBC078PCIBC078ProbeILoI-IIA-580-M/ULCIDCBIA8M/ULCIDCTIA-580M/ULCIDCBIA-580M/ULCIDCTIA-580.M/ULCIVS3IA8M/ULCIDHTIA-580M/ULCIDCTIA-580M/ULCITSHIA-580.M/ULCIDHBIA-580M/ULCIDCB]A-580-M/ULC]VS3IA-580-M/ULCIVS3IA-580-M/ULCIVS3IA-580-M/ULCIVS3IA-580M/ULCITSH]A-580M/ULC]OHBIA-580M/ULCIDHB]A-580-M/ULC]OHTIA580M/ULCIV3IA-SSO.M/ULCIVS3IA-580.M/ULCIDCTIA-580.M/ULCIDCTIA-580-M/ULCIDCB]A-580-M/ULC]TSHIA-580-M/ULCIDCTIA-580-M/ULCIVS3]A-580-M/ULCIvs3IA-580-M/ULCIVSIA-580-M/ULCIDCBIA-580-M/ULCIDCBIA-580-M/ULCIVS3IA-580.M/ULCIDCBIA-SSO.M/ULCIVS3IASM/ULCIDCBIA-580.M/ULCIVS2]A-580-M/ULC]VS4IA-580-M/ULC,IVS2IA-580M/ULCIDHBIA-580.M/ULCIVS3IA-580-M/ULCIVS2IA-SSO.M/ULCIVS2IA-580.M/ULCIVS2IA-580.M/ULCIVS3-I-----------I-Scation.0.0.0.0.7.0.01.4.0~0-.8-1.0-.9-.91.2.3~0-.9-.5~0.0~0.9.0-.5-7.1~1.0~0-1.0.0.1~1~01~1.0.9~0-1.0-.8.9..8..5.sl1.O(.sl.S]~6]~9(]Iz]]I2]Ip2]Iiz]]Iz]]I2]I>>I1.4I137I11l.o]Iiz]slI>>l24]33]zolZl]24]3Z]28]34]21I~9]1.4(]I2]I>>l.7(.r]]Ia]2S]Iizlzs]2.9I141I1I22I.S]1.1].7].S].S]]Izlz3]I>>I36(]Ial39]Ipzlzsl]p2]zz]lpzl23((Ial23]]I2]as/2.0]130]1]32(1.O]~S]4(.9(.9].7].6]~6].7].S].S].9].r].5]]p2(z3]Ii2(3zl(Izl34]]pz]zo]]Iz]22]Ii2]31]Ii2]31(Ip2]zr]]Iz]23]]I2]22(]I2]zs]]pzl24]]Iz]32(]Iz]33]]Izl33]]p2]3ol]Izl24]IIIIIIIIIIIIIIIIIIII=IIIIIIIIII10/95II(Volts]Deg]Ch]X]Diff]LocationN/A]Volts]oeg]chIX]
'
COMPONENT:STG&#xb9;B:20KTO100/DESCRIPTIONINDICATIONS/TRENDINGREPORTPSL-2'Uj'AGE:10/95PageDateTime:11/16/95:08:40:06ProbeILocationIIvs1.olo3c'---I---I---I-I---'----I-(13511011CITEHITEHPsIBc075(A-580-M/ULC(A-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULC(A-580-M/ULCI1611061cITEHITEHI18(106(cITEHITEHI3211061cITEHITEHI50(1061cITEHITEHI96(108(cITEHITEHI521110(CITEHITEHI8911111PSIBC052PSIBC053PSIBC052IBC097Islgco4oPLIBC086103CIvs3Ivs3Ivs2Ivs31.5..8-.9-.9.5C(TEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEN(TENCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHCITEHITEHII--lvs4Ivs2lvs2lvs4IOBHIvs3PSIBC099PS(BC042Ps(Bc042PSIBC042IBC043PLIBC086IA-580-M/ULCIA-580M/ULCIA-580M/ULCIA-580.M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580.M/ULCIA-580.M/ULCIA-580.M/ULCIA-580.M/ULcIA580-M/ULCIA-580-M/ULCIA-580-M/ULCIA-580-M/ULCIA.580-M/ULCI.7-.8.7..8~81.0I96(1141IIIIII(129(115(I52(116(I8911171I5111211I9411241I5511251I6011341I891135(I9411361I7o(138(I55(1391I92(142(I9511431I7611461I82(15olI641152(+-IINumberofIvs2Ivs3Ivs2Ivs3IVs3IDCBIvs4Ivs3lvs3Ivs2Pslgco38SSIBC048PSIBC045PSIBC028PSIBC031PLIBC032PSIBC032PLIBC041PSIBC028PSIBC034PCIBC034PCIBC034PSIBC035-.9.7-.8-7-.9.0.0.6.71~0IVS210IVS21.0Ivs3.0lvs2.oI156PSIBC037--I-----lectedfromRECORDSSeTUBESSoleCurrentOutagerrentOutage:NumberofctedfromCu120IExtentIRoMILin(Leg(Req(Tst/Note(Reel10/95IIN/AI1.11IP21311I.8(IP2(29(IP2123(.5(.911.211.21.5(1.1(.5(.61~61.5(1.21~5(~21.21.5(1.11.8(~8(.6(.61.8(IIP2125(IP2(22(IP2(3o((r2(35(IP2(26(lr2(22(lr2(21(II2(as/Ii2(2ollr2(23(II2(21(II2(2olIP2(34((r2(22((r21241(r2(25(lr2(21(IP2(33(lr2(221(r2(231(r2(2olIP2(2olIIIlvoltsloeg(chIX(Diff(Location(volts(Deglch(XII----I-I---I---I----I-----------I-----I--I--I--+
St.LucieUnit2~~~DocketNo.50-389Fall1995RefuelingOutageL-96-72NIS-1ATTACHMENT31995OUTAGESNUBBERFUNCTIONALTESTINGSUMMARYREPORT Lini2AspartofUnit2RefuelingOutageworkscope,thefollowing,testsandotherrelatedtaskswereperformed:A.Visuallyexamined106of230mechanicalandhydraulicsnubbers.B.Functionallytested27snubberswhichfailedduringthepreviousoutage.Tag-2-019Tag-2-039Tag-2-041Tag-2-066Tag-2-067Tag-2-070Tag-2-093Tag-2-094Tag-2-096Tag-2-102Tag-2-120Tag-2-144Tag-2-146Tag-2-156Tag-2-157Tag-2-169Tag-2-177Tag-2-178Tag-2-183Tag-2-185Tag-2-241Tag-2-242Tag-2-243Tag-2-315Tag-2-316Tag-2-322Tag-2-334C.Functionallytested68of230mechanicalandhydraulicsnubbersaspartoftheselectedsamples.D.Completedactivitiesauthorized'byPlantChange/Modificationpackages:M222M;Modified1snubberduringthisoutage.Tag-1-067,(STAR-2-951523;CRN-279-292-5624)UpgradedwithaLisegaHydraulic.
St.LucieUnit2SnubberTestResultsIudt<ihriaIcashnBmulhGuuura.'~bor:SerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypoSerialNumber:MarkNumberCapacity:RplcmntS/N2-002SMPL-178331/11SS-2-2ALSG-31022-004SMPL-178331/12SSR-2ALSG-3102InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:N/A0240000N/A6.60OA4N/A0240000N/A6.600.445.020.2PassPass5.020.28PassPass156542%Load:.65198868%Load:.835.310.16PassPass5.160.04PassPass162647%Load:.68198762%Load:.83TagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntSIN2-017SMPL-133336-12A1PMHQOInitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:800032000800N/A25.00703.137212579.411.35Pass859.5Pass11.21%Load:1.1637477Pass728.1Fail%Load:1.17PassPassTmber:peSerNumber:MarkNumberCapacity:RplcmntS/N2-019PEV.FAIL33486-1281PMHAOInitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:800032000800N/A25.00552.1Pass358.2Pass11.35Pass12.25Pass37056%Load:1.1639471%Load:1.23420.8Pass247.8PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-023SMPL-161211/61RC-44-R7LSG-3018InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:2105402114.174.726.3Pass7.6550.3%Load:1.025607.6P.ass9.310.20Pass8.352.58Pass1.53Pass%Load:1.04PassPassPassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSumber:mberCapacity:RplcmntS/N2-024SMPL-161211/66RC-44-R7LSG-30182-037SMPL-112504SIR205-4080PSA-10InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:2105402114.174.727500.02120007500N/AN/A8.9Pass12.7Pass555.29.4%Load:1.03564.4Pass12.4%Load:1.05Pass10.052.41PassPass8.42Pass2.51Pass.01312389.331Pass.008PassLoad:1.0311279.2%Load:.94Pass24.7Pass78.5Pass56.9Pass St.LucieUnit2SnubberTestResultsIcsiSrihxiaXemxlEcaulfsCamarade~Brudhber:TpeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumber-Capacity:RplcmntS/N2-038SMPL-219221CH-103-R10APSA-12-039PEV.FAIL38503SI-83-R3PSA-1/438503InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A17.5.0228017.5N/AN/A22.3.0191281.118.813.8.01274.916.4Pass%Load:1.07PassPassPass%Load:.98Pass.0081281.926.323.3.015254.517.5Pass%Load:1.07PassFailPass%Load:.91PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTmber:peSenalNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-040SMPL-129179MSI-9-R88PSA-1/42-041PEV.FAIL61211/738-23-R1ALSG-30182-045SMPL-161211/55CH-108-R4LSG-30182-04611832CH-108-R8PSA-1/438510InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5N/AN/A17.5054017.514.724.722105402114.724.7217.5.0228017.5N/AN/A10.4Pass12.2571.2%Load:1.06553.75.9Pass8.311.28Pass9.502.75Pass2.2610.8Pass16.3563.6.9%Load:1.04533.1Pass10.110.05Pass8.932.59Pass1.995Pass5.011281.5Pass.012%Load:1.01297.3Pass1.73.9Pass3.4.01Pass.01267.5%Load:.96300.14.5Pass3.7PassPass%Load:1.07PassPass%Load:1.03PassPassPassPass%Load:.99PassPassPassPassPass%Load:1.06PassTagNumber:TestTypeumber:umberCapacity:RplcmntS/N2-049SMPL-1376578-15-R10PSA-1/4InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5N/AN/A4.8.0093006.5Pass4.6Pass.009%Load:1.07287.7Pass6PassPass%Load:1.03Pass St.LucieUnit2SnubberTestResultsXm~ltgriaIcnshaEm'umaramaaEesuihber:TeypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-050SMPL-316436SI4201-77418PSA-10InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:.02120002500N/ANIA71.9.0151281776.9Pass82.3Pass.011%Load:1.0712149Pass62.6PassPass%Load:1.01PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-053SMPL-416749SIP200-63438PSA-32-054SMPLA16760SI4200-63438PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A300.024800300N/AN/A16.2Pass20.2Pass.013Pass.006Pass5040.7%Load:1.054210.3%Load:.8821.8Pass14.1Pass18.8Pass16.6Pass.014Pass.009Pass5267.1%Load:1.14201.9%Load:.8819.1Pass16Passmber:SerialNumberMarkNumberCapacity:RplcmntS/N2-055SMPL-417709SIR200-63408PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A20.8.015525217.2Pass30.1PassPass.013Pass%Load:1.095070.6%Load:1.06Pass29.9PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeumber:umberCapacity:RplcmntS/N2-056SMPLA16765SI4200-63408PSA-32-057SMPLR16753SIC200-3268PSA-32-058SMPL-421266Sl-4200-322CPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300NIAN/A300.024800300N/ANIA300.024800300NIAN/A28.5Pass31.6Pass.0125232.324.4Pass.009Pass%Load:1.094613.8%Load:.96Pass25.6Pass18.3Pass14.2Pass.009Pass.007Pass5104.5%Load:1.0621.75162.7%Load:013.8Pass21.7Pass34.8Pass14.2Pass.012Pass.007Pass4760.6%Load:.994791.5%Load:126.3'ass23.4Pass St.LucieUnit2SnubberTestResultsj.CRfCCl~lRXCQRElECS~QglIgZRSK?QhIQRmber:ypeSerialNumber:MarkNumberCapacity:RplcmntS/N2066PREYFAIL16610SI-4203-71PSA-1016610InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:.0212000750N/AN/A145.6Pass.02212887.1Fail%Load:1.07209.9Pass615.7Pass1118Fail.017~Pass12112.2%Load:1.01TagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RptcmntS/Number:peSerialNumber:MarkNumberCapacity:RplcmntS/N2-067PREVFAIL61256/32SI4201-7760LSG-3062RF61256/322-069SMPL-138528SIR208-264BPSA-1/42-070PREVFAILPD87485-1416SIP200-6348PMH-2200InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75001200075014.724.7217.5.0228017.5N/AN/A30001120030030.0030.0013.79Passg.g2Pass2.70Pass2.55Pass6.3Pass6.4Pass.006313.9Pass.005Pass%Load:1.126.5308.4%Load:.02Pass6.5Pass6.9183.8Pass131.1Pass12985.6%Load:1.1612662.1%Load:1.13175.9Pass141.4Pass29.18Pass26.19Pass25.33Pass24.45Pass3.1Pass124.7Pass0Pass0Pass15000%Load:1.2515000%Load:1.251000Fail1000FailTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-072SMPL-314878Sl-4205-6428BPSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A10.5.00812668.3Pass5PassPass.009Pass%Load:1.061307.2%Load:1.09Pass7.2PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-074SMPL-416752SIP205-6713BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A15Pass15.4Pass.010Pass.008Pass4686.3%Load:.984316.2%Load:.920.9Pass11.1PassTagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-075SMPL-416769SIP205-6713BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A30.4Pass16.1.01Pass.0074743.5%Load:.99452823.8Pass23.5PassPass%Load:.94Pass St.LucleUnit2SnubberTestResultsmber:TypoSerialNumber:MarkNumberCapacity:RplcmntSIN2-079SMPL-324734SI-4205-739BPSA-1InitialDrag:Activation:TostLoad:FinalDrag:Lockup:Release:75.02120075NIANIA.0081274.97.415.2PassPass.008Pass%Load:1.061275.9%Load:1.06Pass7.1PassTagNumber:TestTypeSer/alNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-080SMPL-320363SIP205-6428BPSA-12-084SMPL-329504SI-4204-1100BPSA-324745InitialDrag:Activation:TostLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A300.024800300NIANIA7.6Pass10.6Pass.006Pass.008Pass1238.4%Load:1.031307.9%Load:1.0911.2Pass7.2Pass26.5Pass31.7Pass.008Pass.005Pass5369.3%Load:1.124502.8%Load:.9443.1Pass30.8Passmber:peSenalNumber:MarkNumberCapacity:RplcmntS/N2-088SMPL-17419SI4204-1270BPSA-112289InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A26.9.021319.811.1PassPass%Load:1.1Pass30.5Pass.017Pass1313.0%Load:1.0913.6PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RpicmntSIN2-089SMPLR7313SI4204-1270BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075NIAN/A12.6Pass.008Pass1203.4%Load:113.6Pass19.7Pass.006Pass13492%Load'1217.4PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-093PEV.FAIL11971BF-4007-7017PSA-352-094PEV.FAIL8291MS-4100-16APSA-35InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TostLoad:FinalDrag:Lockup:Release:2500.02400002500NIANIA2500.02400002500N/AN/A312.6.01636950226.9545.4.01823576.5PassPass%Load:.92PassPassPass%Load:.01Pass155.5.01743720267.8219.7.018225.1104.7PassPass%Load:1.09PassPassPass%Load:.01Pass St.LucieUnit2SnubberTestResultsXe~ltexiaIcosi'emi@GamareashoEesvlhmber:peSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-096PEV.FAIL2472MS-4100-16BPSA-1002-099SMPL-126006SIQ203-69BPSA-126006InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:6000.02960006000N/AN/A75.02120075N/AN/A1261.4.02952401079.38.1.0151296.34.2PassPass%Load:.99PassPassPass%Load:1.08Pass1410.6Pass.017Pass197230%Load2051167.9Pass6.511.5Pass.018Pass1256.7%Load:1.057.4PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTumber:peSealNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-100SMPL-320360SI4203-69BPSA-169552-102PREVFAIL26062SIP203-24CPSA-12-103SMPL-314872SIR203-24BPSA-1148722-104SMPL-326010SIP203-24BPSA-12-106SMPL-121267SIQ203-581BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A75.02120075N/AN/A75.02120075N/AN/A75.02120075N/AN/A300.024800300N/AN/A16.6Pass18.6Pass.016Pass.011Pass1344.6%Load:1.121349.1%Load:1.1218.5Pass15.1Pass27.6Pass14.8Pass.0091342.412.1Pass.010Pass%Load:1.121339.1%Load:1.12Pass6.7Pass15.2Pass11.2Pass.011Pass.012Pass1310.5%Load:1.091292,3%Load:1.088.3Pass13.0Pass46.8Pass42.9Pass.011Pass.007Pass4901.3%Load:1.02'273.1%Load:.8931.5Pass27.7Pass2.8Pass5.1Pass.010Pass.010Pass1284.3%Load:1.071272.1%Load:1.063.1Pass5Pass St.LucieUnit2SnubberTestResultsbor:TeypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-107SMPLA18680SI4203-581BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:.024800300N/AN/A21.2Pass22.2Pass5119.6%Load:1.074884.6%Load:1.0226.5Pass308PassTagNumber:TostTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-108SMPL-114884SI-4200-314BPSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:?5.02120075N/AN/A12.7Pass8.7Pass.013Pass1197.3%Load:1.0131176.313.7Pass%Load:.98Pass17PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-109SMPLX19231SIP200-314BPSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A7.3Pass6.2Pass.008Pass.007Pass1233.7%Load:1.031263.7%Load:1.058.3Pass5.7PassTmbar.peSerialNumberMarkNumberCapacity:RplcmntS/N2-110SMPL-1113938FP006-7407PSA-10InitialDrag:Activation:TestLoad:FinalDrag:-Lockup:Release:750.0212000750N/AN/A60.7.01812328.348.3PassPass%Load:1.03Pass47.7Pass.01Pass116485%Load9760PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-120PEV.FAIL9282BF-4007-7008PSA-35InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:2500.02400002500N/AN/A294Pass313.7Pass.018Pass.016Pass4p64p%Load;1.p239670%Load:.99109.5Pass80.1PassTagNumber:TestTypoSerialNumber:MarkNumberCapacity:RplcmntS/N2-124SMPL-129366RS-98-R12PSA-1/4InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.02'8017.5N/AN/A5.6.009296.15.1Pass6.4Pass.008%Load:1.06301Pass6PassPass%Load:1.08Pass'ii,TagNumber:)jTestTypeumber:umberCapacity:RplcmntS/N2-125SMPL-037659RC-98-R4BPSA-1/438489InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5N/AN/A4.5Pass4.5.008Pass.007291.9%Load:1.04298.23.5Pass4.6PassPass%Load:1.07Pass St.LucieUnit2SnubberTestResultsXeaGritariaIcllKEEmilyGamKaz~Emdhmber:2-140SMPL-1MarkNumberCapacity:RplcmntS/NRC-99-R5PSA-1/4SerialNumber'2612InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5NIAN/A2.0.011252.1.9PassPass'/0Load:.9Pass2.2.011294.92.8PassPass'/0Load:1.05PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-144PREVFAIL14876RC4300-15PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/ANIA22..011294.335.2PassPass'/oLoad:1.08Pass48.5.011233.442.0PassPass0/0Load:1.03PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTumberpeSNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-146PEV.FAIL16442RCP300-123PSA-102-150SMPL-114880RCQ300-125PSA-1260022-152SMPL-216141RC-4300-28PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:750.0212000750'/ANIA75.02120075N/AN/A75.02120075N/AN/A78.01912418.82513.0161227.612.410.0171212.75.1PassPass'/oLoad:1.03PassPassPasso/0Load:1.02PassPassPass'/oLoad:1.01Pass64.8Pass.012Pass113p3.3/oLoad:.94476Pass11.5Pass024Fail1203.8'/oLoad:116.1Pass9.8Pass.016Pass1285.5/0Load:1.074.6PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-153SMPL-116568RC-4300-26BPSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A38.8.0174916.339.4Pass37.3PassPass.01Pass'/0Load:1.024453.9'/0Load:.93Pass46.0PassTagNumber:TestTypeumber:umberCapacity:RplcmntS/N2-155SMPL-110177RCQ300-126PSA-10InitialDrag:Activation:.TestLoad:FinalDrag:Lockup:Release:750.0212000750N/AN/A20.6.01912751.672.1PassPass'/oLoad:1.06Pass16.9Pass.017Pass1p576.2/0Load:.8842Pass


St.LucieUnit2SnubberTestResultsIQSfSZliQdRTi~ggggjg~~~QgggJQber:TeypeSerialNumber:MarkNumberCapacity:RpicmntS/N2-156PREVFAIL12790RCR300-64BPSA-126008InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:.02120075N/AN/A.0071348,414.6Pass.010%Load:1,121250.2Pass10.5Pass%Load:1.04Pass10.8Pass13.5PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-157PREVFAIL15148RC4300-7066PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A19.6.0161301.65.3PassPass%Load:1.08Pass.0171255.915.9Pass%Load:1.05Pass25.2PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/Nmber:peSerialNumberMarkNumberCapacity:RplcmntSIN2-160SMPL-220253RC<300-12PSA-32-161SMPL-220262RCC300-12PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A300.024800300N/AN/A12,013515513.117.9.013505111.4Pass12.8Pass.008%Load:1.074338Pass13.1Pass8.7Pass'008%Load:1.054382Pass15.6PassPass%Load:.9PassPassPass%Load:.91PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-162SMPL-211387RCP300-157PSA-102-165SMPL-216439RC<300-157PSA-10InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:750.0212000750N/AN/A750.0212000750N/AN/A53.5Pass42.5Pass.01912280.851.7Pass.011Pass%Load:1.0211225.9%Load:.94Pass36.5Pass70Pass59.4Pass.02Pass.017Pass11494.2%Load:.9610744.9%Load:.972.6Pass72.5PassTagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-167SMPL-1PD87773-1891RC-4300-147PMH-2200InitialDragActivation:TestLoad:FinalDrag:Lockup:Release:30001120030030.0030.00184.1Pass224.626.8522.93PassPass24.5322.2813596.4%Load:1.2113142163.3Pass205.1Pass%Load:1.17PassPassPass St.LucieUnit2SnubberTestResults3y~CihriajenaiuahigaQgmgrmgigafhgglhber:TeypeSerialNumber:MarkNumberCapacity:RplcmntSINTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/Nmber:SerialNumberMarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-169PREVFAIL101RCP300-139PSA-32-170SMPL-220264RC-4300-138PSA-32-172SMPL-28934RCQ300-6134CPSA-102-173SMPL-111340RC-4300-6134CPSA-102-176SMPL-2'?RC-4300-6134APSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A300.024800300N/AN/A750.0212000750N/AN/A750.0212000750N/AN/A300.024800300N/AN/A33.9Pass25.5Pass.013Pass.008Pass5229.1%Load:1.094497.5%Load:.9411.3Pass14Pass49.7Pass67.1Pass.02Pass.014Pass11174.6%Load:.9311373.1%Load:.9523.2Pass346Pass52.5Pass42.2Pass.017Pass.012Pass11274.7%Load:.9411141.0%Load:.9337.5Pass377Pass74.5Pass80.8Pass.012Pass.011Pass5193.5%Load:1.084640.3%Load:.9717.2Pass18.9Pass36.1Pass28.5Pass.012Pass.008Pass4887%Load:1.024262.6%Load:.8915.5Pass10.4PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeumber:umberCapacity:RplcmntS/N2-177PREVFAIL29182RC-97-R18PSA-1/42-178PREVFAIL29198RC-97-R18PSA-1/4InitialDragActivation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5N/AN/A17.5.0228017.5N/AN/A5.3Pass6.3.013Pass.013294.8%Load:1.05276.58.2Pass4.46.3Pass7.2.01Pass.009273.7%Load:.98305.18.1Pass5.3PassPass%Load:1.09PassPassPass%Load:.99Pass St.LucieUnit2SnubberTestResultsIm~C'aiaXeamulEmittedGmareaahnEmitmber:TypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-183PEV.FAIL16663RC-4300-1067PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A7.5Pass.01Pass.017Pass7.5%Load:.0110.3%Load:.017.5Pass10.3PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RpicmntS/N2-184SMPL-219228RC-4300-1067PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A9.6.016130010Pass4.3Pass.018%Load:1.081319Pass5.3PassPass%Load:1.1PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/Number:peSenalNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-185PREYFAIL30534RC4300-52PSA-32-186SMPL-116575RC-4300-53BPSA-32-196SMPL-19281MS-4101-314PSA-352-200SMPL-321579SI-80-R5PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/ANIA300,024800300N/AN/A2500.02400002500N/ANIA75.02120075N/AN/A37.6Pass45.1Pass.013Pass.008Pass5295.8%Load:1.14643.5%Load:.9740.Pass41.4Pass31.7Pass31.2Pass.014PassPass4668.4%Load:.97%Load:.97.014660.930.130.1PassPass42.5Pass79.4Pass10.3Pass7.9Pass.008.Pass.008Pass1305.1%Load:1.091322.1%Load:1.14.2Pass14.5Pass218.5Pass208.6Pass.015Pass.018Pass35170%Load:.8842270%Load:1.06TagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-206SMPL-119077MSIQ-R6PSA-1/4InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5.0228017.5NIAN/A6.6Pass8.6.011Pass.012303.3%Load:1.08296.34.0Pass4.8PassPass%Load:1.06Pass
==SUMMARY==
EXAMINATION AREA                    CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDEHTIFICATIOH                    ITEM NO  METHOD      PROCEDURE          C G M R  *"CALIBRATION BLOCK**
REF. DWG. NO.
02-004'18600 TUBE BUNDLE                        B-Q      ECT        HDE 1.3            - - - X 11/9/95 - 8,213 tubes examined, 156 U-TUBES                            B16.20                                            indications, seven tubes plugged this outage for corrosion and wear progression


St.LucieUnit2SnubberTestResultsIg.'~Cm:fgICllKKlECSlklhQ5KS~rgignber:TeypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-211SMPL-416578Sl-2401<4PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300NIANIA14.1Pass.012Pass.008Pass5190.1%Load:1.084961.1%Load:1.0320.4Pass130PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-219SMPL-320259CC-2061-101PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/ANIA18.1.0114513.817.5PassPass%Load:.94Pass12.7.0084267.13.2PassPass%Load:.89PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-222SMPL-17817SI-2412-29APSA-35InitialDrag:Activation:TestLoad:FinaIDrag:Lockup:Release:2500.02400002500N/ANIA208.9Pass119.4Pass.016Pass.015Pass36490%Load:.9137300%Load:.9356.3Pass302Passmber:SerialNumberMarkNumberCapacity:RplcmntS/N2-224SMPL-110719CH-2081-685BPSA-1/2InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:37.5.0252037.5N/AN/A4.4.013532.88.4Pass6.6Pass.01%Load:1.02535.8Pass6.3PassPass%Load:1.03PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeNumber:umberCapacity:RplcmntS/N2-240SMPL-316761BF-3020-14BPSA-32-241PREYFAIL7809MSP102-33PSA-352-242PREYFAIL7810MS-4102-33PSA-35InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/ANIA2500.02400002500N/AN/A2500.02400002500NIANIA17.7Pass15.1Pass.01Pass.008Pass5147,4%Load:1.p74643.2%Load:.9718.1Pass106Pass148.9Pass121.5Pass.02Pass.018Pass39050%Load:.9839540%Load:.99197.6Pass85.8Pass272.8Pass251.4Pass.019Pass.018Pass4237p%Load:1.p64211p%Load:1.05276.8Pass222.6pass St.LucieUnit2SnubberTestResults~~CittJ:jgICl5jQDBCSQlfRQgm~~hiljtg,TagNumberTestTypeSerialNumberMarkNumberCapacity:RplcmntS/N2-243PEV.FAIL7808MS4102-287BPSA-35InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:2500.02400002500N/AN/A211.2.01739760333.4PassPass%Load:.99Pass195.1Pass.015Pass39760%Load:.9!1996PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypoSerialNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerial5lumberMarkbomberCapac".I;Rplcrt.tS/NTagtlaber:Test~"poSerla<Number:MarkNumberCapac>ty;RplcmntS/N2-246SMPL-17814MS-4102-287APSA-352-268SMPL-161242/04BF4004-258LSG-30522-269SMPL-161242/03BF-4004-258LSG-30522-315PREVFAIL8458MS4102-284PSA-35InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:2500.02400002500N/AN/A300054030014.174.72300054030014.174.722500.02400002500N/AN/A63.3Pass64.6Pass5635.043.1%Load:10.445469.5Pass42.6%Load:10.Pass12.39Pass11.06Pass1.95Pass1.46Pass71.8Pass71.6Pass54657%Load:54254%Load:10I:56.6IMP415Pass12.95Pass10.07Pass1,90Pass1.45Pass508.Pass315.6Pass.014Pass.015Pass37440%Load:.9443720%Load:1.0<396.5Pass4162Pass216.4Pass203.2Pass.018Pass.017Pass40580%Load:1.0142140%Load:1X238.6Pass223.5PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-316PREVFAIL25740BF-4004-38PSA-3InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A45.5.0124892367.6Pass,46.3Pass.006%Load101944279Pass37.9PassPass%Load:9.;lPassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-322PREVFAIL61211/58MS-7-R2BLSG-3018InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:17.5028017.514.724.7214.6Pass15.811.58Pass9.033.13Pass3.13558.9%Load:2556.69.9Pass9.8Pass%Load:1.99PassPassPass
DATE:   02/23/96                                ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:     4 REVISION:       0                            INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS RIZER N  I   0 ZONE NUMBER:   2-005                  ASME                                      OHGT SEC. XI                                  RSEH


St.LucieUnit2SnubberTestResults~~CIJ:is[1CEdQQBRRLjJJRGQIEZRKigQECgglflimber:ypoSerialNumber:MarkNumberCapacity:RplcmntS/N2-323SMPL-126064MS-3023-11BPSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A27,7.0051277.929.4Pass42.3Pass.004%Load:1.061242.1Pass40.1Pass%Load:1.04PassTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-324SMPL-326005MS-3023-53PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A9.4.0071273.44.5PassPass%Load:1.06Pass6.9Pass.007Pass12865%Load107PassTagNumber:TestTypoSerialNumber:MarkNumberCapacity:RplcmntS/N2-325SMPL-221596MS-3023-93PSA-1InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:75.02120075N/AN/A20.2Pass21.3Pass.015Pass.016Pass1294.2%Load:1.081208.7%Load:1.0114.4Pass20.6Passumber:peSeiaiNumber:MarkNumberCapacity:RplcmntS/NTagNumber:TestTypeSerialNumber:MarkNumberCapacity:RplcmntS/N2-332SMPL-225526SI-2401-171PSA-32-334PREVFAIL61211/67VRC-4-R3LSG-3018InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:InitialDrag:Activation:TestLoad:FinalDrag:Lockup:Release:300.024800300N/AN/A17.5032017.514.724.7247.9.0145218755.53.415653.311.573.53Pass39.1Pass7.7Fail%Load:1.77585Pass7.6PassPass8.?72.31Pass.007%Load:10.8745882Pass35.3PassPass%Load:9.56PassPass%Load:1.83PassPassPass St.LucieUnit2~~~DocketNo.50-389Fall1995RefuelingOutageL-96-72NIS-2OWNER'SREPORTSOFREPAIRSORREPLACEMENTS NIS-2NumberSL-2-7-001SL-2-7-010SL-2-7-011SL-2-7-012SL-2-7-014SL-2-7-019SL-2-8-001SL-2-8-002SL-2-8-003SL-2-8-004SL-2-8-005SL-2-8-006SL-2-8-007SL-2-8-008SL-2-8-009SL-2-8-010SL-2-8-011SL-2-8-012SL-2-8-013SL-2-8-014SL-2-8-015SL-2-8-016SL-2-8-017SL-2-8-018SL-2-8-019SL-2-8-020SL-2-8-021SL-2-8-022SL-2-8-023St.LucieNIS-2ReportsDate10/21/9411/9/9311/8/9312/30/924/19/934/19/937/28/942/7/967/12/95WorkingCancelledCancelledCancelled6/28/95CancelledCancelledCancelledWorking12/12/94Cancelled2/9/95Notused6/22/956/22/956/30/952/6/967/12/9511/25/961/22/96 SL-2-8-024SL-2-8-025SL-2-8-026SL-2-8-027SL-2-8-028SL-2-8-029SL-2-8-030SL-2-8-031SL-2-8-032SL-2-8-033SL-2-8-034SL-2-8-035SL-2-8-036SL-2-8-037SL-2-8-038SL-2-8-039SL-2-8-040SL-2-8-041SL-2-8-042SL-2-8-043SL-2-8-044SL-2-8-045SL-2-8-046SL-2-8-047SL-2-8-048SL-2-8-049SL-2-8-050SL-2-8-051SL-2-8-052SL-2-8-053St.LucieNIS-2Reportsi2/13/9511/22/9511/14/9511/14/9511/29/9511/29/95Cancelled12/19/9512/4/95i2/13/9512/11/9512/11/9512/1/9511/25/9511/29/9511/25/95i2/2/9512/12/9512/5/9511/27/9512/12/9512/18/95ii/17/95ii/i3/9512/18/9512/13/951/18/9611/29/9512/7/9512/7/95 SL-2-8-054SL-2-8-055SL-2-8-056SL-2-8-057SL-2-8-058SL-2-8-059SL-2-8-060SL-2-8-061SL-2-8-062SL-2-8-063SL-2-8-064SL-2-8-065SL-2-8-066SL-2-8-067SL-2-8-068SL-2-8-069SL-2-8-070SL-2-8-071SL-2-8-072SL-2-8-073SL-2-8-074SL-2-8-075St.LucieNXS-2Reports11/2/9511/17/9512/27/9512/18/9511/14/9512/18/9511/21/9511/24/9511/20/951/18/96NotUsed12/27/9511/29/9511/28/9512/27/9512/27/951/22/9611/14/95CombinedwithSL-2-8-07011/20/9512/12/951/22/96SL-2-8-076SL-2-8-077SL-2-8-078SL-2-8-079SL-2-8-080SL-2-8-081SL-2-8-082SL-2-8-08312/19/9512/8/951/2/9612/1/9511/30/9512/14/9512/14/953ISINst~ls~
==SUMMARY==
EXAMINATION AREA              CATGY      EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION              ITEM NO    METHOD      PROCEDURE        ,C  G M R **CALIBRATIONBLOCK**
REF. DWG. HO. 02-005-B 018700  103-601                      8-D        UT 0        HDE 5.1-25        X  - - - 10/23/95 . UT complete SPRAY NOZZLE TO UPPER HEAD  B3.110    UT 45      NDE 5.1-26        X  - --
UT 60      HDE 5.1-27        X  --
UT 70      HDE 5.1-28        X  - --
                                                                                        **UT-4A**
REF. DMG. NO. 02-005-A 018800  SN-IR                        B.D        UT 30      NDE 5.13-4        X  - - - 10/23/95 - UT complete SPRAY NOZZLE INNER RADIUS    B3.120    UT 70      HDE 5.13-6        X---
SECTION
                                                                                        **UT-6, UT-17">>
REF. DMG. NO. 02-005-B 108-601-A                  8-D        UT 0        HDE 5.1-29        X  - - - 10/24/95 - UT complete, acceptable slag SAFETY VALVE NOZZLE TO HEAD  83.110    UT 45      NDE 5.1-30        X---
UT 60      HDE 5.1-31                X UT 70      HDE 5.1-32        ---X UT 60      HDE 5.1-33        - - - X **UT-4A**
UT 70      HDE 5.1-34            - - X REF. DWG. NO. 02 005 A 019000  SVN-IR-A                    B-D        UT 30      HDE 5.13-3        X  - - - 10/23/95 - Ul'omplete SAFETY VALVE NOZZLE INNER    83.120    UT 70      NDE 5.13-5        X-RADIUS SECTION
                                                                                        *>>UT-6, UT-17
* 019100  503-671-A                    B-F        PT          HDE 3.3-44        X--     10/20/95 - PT complete, 10/21/95 - UT NOZZLE TO FLANGE            B5 ~ 40    UT 30      HDE 5.4-56        X-       complete, limited examination from the UT 45      HDE 5.4-57        X--     nozzle side due to its configuration UT 45      HDE 5.4-58        X--
                                                                                        **UT-17>>*


SL-2-8-084SL-2-8-085SL-2-8-086SL-2-8-087SL-2-8-088SL-2-8-089SL-2-8-090SL-2-8-091SL-2-8-092SL-2-8-093SL-2-8-094SL-2-8-095SL-2-8-096SL-2-8-097SL-2-8-098SL-2-8-099SL-2-8-100SL-2-8-101SL-2-8-102SL-2-8-103SL-2-8-104SL-2-8-105SL-2-8-106SL-2-8-107SL-2-8-108SL-2-8-109SL-2-8-110SL-2-8-111St.LucieNIS-2Reports12/18/951/4/9612/27/95i2/i3/9511/29/9512/13/9511/25/9512/7/95i/2/962/5/962/5/9611/29/9511/29/952/1/9612/11/9512/2/9512/8/9512/6/9511/29/9511/28/9511/28/9511/30/95Cancelled1/4/96CancelledCancelled2/6/96Cancelled PSL-1,NIS-2TRACKINGNO.SL-2-7-~001FFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo:P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJcnscnBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957IIDate:10/21/94."Sheen1of4Unit:2P.O.&#xb9;:NAPCM&#xb9;:178-290PWO&#xb9;:4794WO&#xb9;:CWO&#xb9;:92040566NAProcessSheet:N/A4.(a)IdentificationofSystem:IntakeCoolingWater(b)ComponentIdentification:ICWPP2B(MarkNumber)(c)CodeClass:3TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:AsMESEcTtONIII1986EDrraNNoADDfNDACodeCase:NA(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdcntiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedStampedor(YorN)ReplacementPump(Lessstuffingbox)Pump(Lessstuffingbox)ColumnBoltingCapscrewsColumnBoltingCapscrewsStud-StuffBxtoDischargeHeadStud-StuffBxtoDischargeHeadByronJacksonJohnstonPumByronJacksonBWIDByronJacksonByronJackson761-N-0002901-A-3554Ht&#xb9;.M2943B/16&M2943B/17Ht&#xb9;M9591BNANANANANANA14,000GPM1980130ft14,000GPM130ftAMSS-16411/4-7unc'5ASMESB16411/4-7unc'5ASM'B.1643/4~10uncx31/2ASM'B1643/410uncx31/2ReplacedReplacementReplacedReplacementReplacedReplacementN7.DescriptionofWork:REPLACEPUMPW/MODIFIEDPUMPWHICHWILLPROVIDEIMPROVEDLUBEWATERFLOWTOBEARINGS.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)xOther:VTIVT2xVT3~psigTestTemp.~'F
DATE:  02/23/96                                  ST. LUCIE NUCLEAR PLANT UHIT 2                                     PAGE!      5 REVISION:       0                            INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS RIZER N I  0 NUMBER!    2-005                  ASME                                      ONGT SEC ~ XI                                  RSEH


PSL-2,NIS-2TRACKINGNO.SL-2-7-~001FORMNIS-2(Back)Sheet2of49.Remarks:10.InspectionReportNumbers:NAAPPLICABLEMANUFACTURESDATAAEPOttTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairxReplacementconformstotherulesoftheASMECode,SectionXI.ATypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignednerOwner'sDesignee,TitleDate~2.t,19t'fCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;7startingon06/92,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissions1NationalBoard,State,ProvidenceandEndorsementDate PSL-1,NIS-2TRACKINGNO.SL-2-07-~001FORMNIS-201VNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASiMECodeSectionXIPLSUPPLEMENTALSHEET1.Owner.2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LuciePlant6501SouthHwy.AIAJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1ADate:4/22/94Sheet:3of4Unit&#xb9;:2P.O.&#xb9;:NAPCM&#xb9;:178-2906.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentNut-StuffBoxtoDischargeHeadNameofManufacturerByronJacksonManufacturerBdOtherNationalSerialNo.NIdentificationBoardNA3/4-touncHvyHYearBuiltNAReplacedASMERepairedCodeorStampedReplacement(YorN)ReplacedNut-StuffBoxtoDischargeHeadNuts-DischargeHeadtoPedestalNuts-DischargeHeadtoPedestalBWIPByronJacksonNovaHt&#xb9;M2473BQHt&#xb9;17155NANAASMESB-16414uncHexASMESB-16414uncHvyHexNA3/4-10uncHvyHNANANAReplacementReplacedReplacementStuds-DischargeHeadtoPedestalStuds-DischargeHeadtoPedestalCapscrews-SuetBelltolmplrcaseCapscrews-SuetBelltoImplrcaseNuts-SuetBelltoImplrcaseNuts-SuetBelltoImplrcaseStuds-TopCasetoImplrCaseStuds-TopCasetoImplrCaseNuts-TopCasetoImplrCaseByronJacksonNovaByronJacksonBWIPByronJacksonBWIPByronJacksonBWIPByronJacksonHt&#xb9;22520ReiPODocRefPODocHt&#xb9;M2944BNANANANANA,ASMESB-1641"-Sunc-41/2"ASMESB-1641"-Sunc-41/2"ASMEB-1643/4"-10unc-4"ASMEB.1643/4"-10unc-4"ASTMB-1643/4"-10uncASTMB-1643/4"-10uncASMESB1643/4"-10unc-4"ASMESB1643/4"-10unc-4"3/4-1ouncNANANANANANANANANAReplacedReplacementReplacedReplacementReplacedReplacementReplacedReplacementReplacedNNuts-TopCasetoImplrCaseHexNuts,ColumnBoltingHexNuts,ColumnBoltingByronJacksonByronJacksonNovaHt&#xb9;M9539BHt&#xb9;37165NANAASMESB-16411/4"-7uncASMESB-16411/4"-7uncHxNA3/4-louncHvyHNANANAReplacementReplacedReplacement PSL-I,NIS-2TRACKINGNO.SL-2-07-~001FPLFORMNIS-2OAVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXISUPPLEMENTALSHEETl.Owner.FloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:4/22/94Sheet:4of42.Plant:St.LuciePlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AUnit&#xb9;:2P.O.&#xb9;:NAPCM&#xb9;:178-2906.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentNameofManufacturerManufacturerSerialNo.'ationalOtheryearBoardIdentificationBuiltNo.ReplacedRepairedofReplacementASMECodeStamped(YorN)Capscrews-ColumnTopCaseCapscrews-ColumnTopCaseByronJacksonBWIPHt&#xb9;M33C2BG/111NAASMESB-16411/8"-7unc-5"ASMESB-16411/8"-7unc-5"NANAReplacedReplacementHexNuts-ColumnTopCaseHexNuts-ColumnTopCaseStuffingBoxByronJacksonBWIPByronJacksonHt&#xb9;M2107BGNANAASMESB-16411/8"-7uncASMESB-16411/8"-7uncNANAASMESB-148NACDA954ReplacedReplacementReplacedStuffingBoxStuffingBoxPlugStuffingBoxPlugByronJacksonByronJacksonByronJacksonHt&#xb9;M4659NFHt&#xb9;674TNENANAASMESB-148CDA954SB-564NANANAReplacementReplacedReplacement PSL-1,NIS-2TRACKINGNO.SL-2-7-~010FORMibIS-2OWNER'SREPORTFORREPAIRSORREPLACEi3IIENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957'.(a)IdentificationofSystem:ReactorCoolantPRESSURIZER(b)ComponentIdentification:V1201(MarkNumber)(c)CodeClass:1Date:11/9/93ShceL'ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5658WO&#xb9;:92055870CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStamp,N/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeANSIB31.7,1969Edition.Addenda:N/A.CodeCase:NA(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1980Editionthruwinter19806.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalSerialorHeatBoardNo.No.OtherIdentificationYearBuiltReplacedRepairedofReplacementASMECodeStamped(YorN)SAFETYVALVESAFETYVALVECROSBYCROSBYN59336-00-0002N59336-00-0004NANANA1979REPLACED1984REPLACEMEYALLTHREADNOVAMACHINE11/4"X8UNX2APRODUCTSHEAVYHEXNUTSNOVAMACHiNEPRODUCTSHEAT&#xb9;67094HEAT&#xb9;8094962NASA-193GRB7SA-194GR7NAREPLACEMENAREPLACEME7.DescriptionofWork:Replacevalveandinletboltingduetoseatleakage.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)xOther:VT1xVT2xVT3~~psigTestTemp.~'F PSL-2,NIS2TRACKINGNO.SL-2-7-~010FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSERVICELEAIVGETESTWASPERFORMEDANDALLREPLACEMENTBOLTINGWASVISUALLYEXAMINEDBYAVTCERTIFIEDINSPECTOR.10.InspectionReportNumbers:M93-369APPLIDABLEMANUFADTUAE'SDATAREPORTSToBEATTADHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairxReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/A'SignedOwnerorOwner'sesignee,TitleDate~is<.19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;7startingon06/92,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissions1FCo&#xb9;60NationalBoard,State,ProvidenceandEndorsementDate JL.-l6-199213c85FROf'1OPPD-CORPSPROCQA\aTO91404684115P.82CRbSOYVAlVF448'8CO0PALYWIth~THAM,MASSiORMNV1FORSA,FE'Z'fh&#xc3;DSIAFETYRRXJEFVAlVESharequiredbychefrovislonsotcbaActi@CodeRulesDATAREPORTSafetyandSafetyReliefValtteeClaC.MC-ll.atanuractcuaayCrosValve6CrteCo.43KendrickS.hrrenthcttnMA2learnsandAddressJISXlXI,JLaaa,IdDD-EP86OeddaPewaa&LldhtCOOPaoy,9.0.DOxDZ9990QacanufacturedForHiamL.Floride33252Ordertfo.18656>>22976%3926NllmeandAddressFloridaPotrer6Yd.htCompanySt.LuciaUttit82*OWlcfNamnandhddress4.l:ocatinnafPlantdaSpareforV>>1200,V-1201,V12025.VahwidentificationSerialNo.aReliefQdety.safetyRelief.lhllct.lhowarActuatedS.Sccpressuro<psfa)2129182lbslhr'tsteotusatStampedCafztnttyctN5933600-0004DfaigNo.DS059336Rev.EeeldaoaltaKpleaalta!alta90Oaalhahlochlaahlaoh700FtSmpvrature~~Qvsrp:useureBlowdovyn(pala)4~O<Se>.HtedfrhlhtattnTeat(iPQQ)inlet3750CompleceValveT.Tbepnacsrzatdesign,oOnsuucctonandvrorkrnanshtpcomplyvpichAgMK,'Code.Sectionlg.Oha,1~ddhdon9.hddaodaDateDohddaodapressureConcaincrucortzressureRvcainingCumpcznvnts,CaseNo.a.CasczngsK60802-32-0004BodyBonnetP~rScoc:kandFotgtngsSalPPrar~EOttQBthloaxl~DiscXneertSerialNo.identificationN9L522-33-0004N9153032-0004N91523-34-0008250007idatcrialspenlfioationincludingTypeotbeadsASIDESA35LGr.CPSARKSALOSAS'458Cx.651A48springcsasbersK60807-32-0004~IAdiustingBoltSp.Poult'RN8O6-33-0008Spindl.eBal3.DiscHolderBellowtrK6080533-0005LcushingN9153235-0008N91527330007h'9152SN91524~360008NSL525-34-0008ASMSA193Gr.B6ASHZSA193Gr.S6A$.A276Te440CAS'KSA637Gr.718HttyttcsSatelliteAlloyNo.68
==SUMMARY==
EXAMINATION AREA              CATGY      EXAM                          E  I 0 E REMARKS HUHBER  IDENT  IF ICATION              ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
REF. DWG. HO. 02-005-A 019200  SV-1200                      B-G.2     VT-1        HDE 4.1-29        - - - X 10/25/95 - VT-1 complete, inadequate SAFETY VALVE FLANGE BOLTING  87.50      CNR        95-2-004                    thread engagement on one nut, acceptable per letter JPN-PSL-88-070 REF. DWG. NO. 02-005-8 019300  108-601-8                    8-D        UT 0        NDE 5.1.25        X--     10/23/95 - UT complete RELIEF VALVE NOZZLE TO UPPER  83.110    UT 45      NDE 5.1-26        X---
HEAD                                    UT  60      NDE 5.1-27        X---
UT 70      NDE 5.1-28        X---
                                                                                          **UT-4A<<*
REF. DWG. NO. 02-005-A 019400  RVH- I R                      B-D        UT  30      NDE 5.13-3         X  - - - 10/23/95 - UT complete RELIEF VALVE NOZZLE IHNER    83.120    UT 70      HDE 5 ~ 13-5      X  . --
RADIUS SECTION
                                                                                          <<<<UT-6, UT-17<<*
REF. DWG. HO. 02-005-8 019500  108-601-C                    8-D        UT 0        NDE F  1-25      X---     10/23/95 - UT complete SAFETY VALVE NOZZLE TO UPPER  83.110    UT 45      HDE F  1-26      X---
HEAD                                    UT  60      NDE 5.1-27        X---
UT  70      HDE 5.1-28        X---
                                                                                          **UT-4A"*
REF. DWG. HO. 02-005-A 019600  SVH-IR-8                     8-D        UT 30      NDE 5.13-3        X  - - - 10/23/95 - UT coaplete SAFETY VALVE NOZZLE INNER    83.120    UT 70      NDE 5 '3-5        X---
RADIUS SECTION
                                                                                          <<*UT-6) UT-17
* DATE:  02/23/96                                  ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:    6 REVISION:       0                              INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS RIZER N  I  0 ZONE NUMBER: 2  005                    ASME                                      ONGT SEC ~ XI                                  RSEH


~~~II~~tI~~111'~~~~~~1~~~~~~~Ii:~~~~~V~I~~~4~,~~\I~~~~~~'~~~~~~~Vt+i<I~I~~I~~~~~~I~~~~'~~~~~~~Vl~~~
==SUMMARY==
EXAMIHATIOH AREA                CATGY      EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION                ITEM NO    METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK*"
REF. DWG. NO. 02-005-A 019700  503-671-8                      8-F        PT          NDE 3.3-44        X--      10/20/95 - PT conplete, 10/21/95 UT SAFETY VALVE NOZ2LE TO FLANGE  85.40      UT  30      HDE 5.4 56        X        complete, limited examination from the UT 45      HDE 5.4-57        X--      nozzle side due to its configuration UT 45      HDE 5.4-58        X--
                                                                                          **UT-17
* 019800  SV-1201                        8-G-2      VT-1        HDE 4 ~ 1-28      X  - - - 10/25/95 - VT-1 complete, 8 nuts and SAFETY VALVE FLANGE BOLTIHG    B7.50                                              studs examined REF. DUG. No. 02-005-B 019900  108-601-0                      B-D        UI'        NDE 5.1-25        X  - - - 10/23/95 - UT  complete SAFETY VALVE NOZZLE TO UPPER  B3.110    UI'5        NDE 5.1-26        X  - --
HEAD                                      UT  60      HDE 5.'1-27        X  - --
UT  70      NDE 5.1-28        X  - --
                                                                                          <<<<UT-4A<<<<
REF. DUG. NO. 02-005-A 020000  SVN-IR-C                      8-D        UT 30      NDE 5.13-3        X  - - - 10/23/95 - UT  complete SAFETY VALVE NOZZLE INNER      83.120    UT 70      HDE 5.13-5        X---
RADIUS SECTION
                                                                                          <<*UT-6( UT-17
* 020100  503-671-C                      8-F        PT          HDE 3.3-44        X--      10/20/95 - PT complete, 10/21/95 UT SAFETY VALVE NOZZLE TO FLANGE  B5.40      UT  30      HDE 5.4-56        X--      complete, limited examination from the UT 45      HDE 5.4-57        X-      nozzle side due to its configuration UT 45      NDE 5.4-58        X--
                                                                                          <<*UT 17*<<
020200  SV-1202                        8-G-2      VT-1        NDE 4.1.27        X  - - - 10/25/95 - VT-1 complete SAFETY VALVE FLANGE BOLTING    87.50


PSL-1,NIS-2TRACKINGNO.SL-2-7-~011FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:V1202(MarkNumber)4.(a)IdentificationofSystem:ReactorCoolantDate:11/8/93Sheet:IofUnit:2P.O&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5657WO&#xb9;:92055869CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:15.(a)ApplicableConstructionCodeANSIB31.7,1969Edition.Addenda:N/A.CodeCase:NA(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1980Editionthruwinter19806.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalSerialorHeatBoardNo.No.OtherIdentificationYearBuiltReplacedASMECodeRepairedStampedor(YorN)ReplacementSAFETYVALVECROSBYN59336-00-0003NANA1979REPLACEDSAFETYVALVEALLlHREAD11/4"-8UN-2ACROSBYNOVAMACHINEPRODUCTSHEAVYHEXNUTSNOVAMACHINE11/4"-8UN-2BPRODUCTSN59336-00-0005HEAT&#xb9;8094962HEAT&#xb9;RL3NA'ANANA1987SA193-74GRB71989SA-194GR71990REPLACEMEREPLACEMEREPLACEME7.DescriptionofWork:Replacevalveandinletboltingduetoseatleakage.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)xOther:VTIxVT2xVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-7-~011FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSERVICELEAKAGETESTWASPERFORMEDANDAUREPIACEMENTBOLTINGWASVISUALLYEXAMINEDBYAVTCERTIFIEDINSPECTOR.10.InspectionReportNumbers:M93-370APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepair+xReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedor0er'sDesignee,TitleDa1s~xlIa,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;7startingon06/92,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionstNationalBoard,State,ProvidenceandEndorsementDate t.KUSIIY'L'ALYF.F.SGQloCNOIIYYALVK86AGKCOMPANYCRaS'BYWftKHTHAM,MASSFORMgVIFORSAFETYhgDSAFETYRELIEFVALVEShsrequitedbytheProvisionsoftheASMECodeRulesDATAREPORTSafetyandSafetyReliefValvesaC.-vC-lfturedByCrosbyVa1ve&Gae.Co.,43KendrickSt.WrenthatnMAgameandAddresshlceelHc.OrderNoHB-BP"66N74620ContractDaty11/10/86VatlooalBoardNo.PioridaPower&LightCo.POBoxOI99ManufacturedForMa>>,Florida33102Ordergo.C18656-79388gameandAddressFloridaPower&LightCompanygameandhddtessSt.LucieUnit2JensenBeach,Plorida4.LocattonofPlantS.ValveIdentificationSareSerialgoN59336-00-0005Diawl%goDs-C-59336.Rev.ESafetySafety,SafetyRelief.Pilot,PowerActuateds.SetPtessute(PSIQ)2485212,182LBS/HRSatStmStampedCa)3acity~tloclllccSlee'loeSleelelelocIleI1.53136lIIclllechlechlllch700RatedTetnperatutevOverpressute.BIowdown(PSIQ)4XofS.P.FIlydrrstaticTest(PSIO)inlet~50CompleteValve707.Thematerial.design.constructionandwotkmanshipcomplywithASMECode,Sectionm.NoAddenda,CaseNo.PressureContainingorPtessuteRetainingComponentsa.CastingsBodyK60802-33-0005Bonnetb.BarStockandForgingsZKtNIMPdKBonnetgoasleDiscInSertspr>rigNashersK60807-80-0011AdjustingBoltSpindleK60806-34-0009SpindleBallDiscHolderAssyK60805-80-0009DiscBushingSerialgo.IdentificationN1522-80-0005N91530>>80-0005N91523-36-0013N91526-80-0017N1531-3VtN91532-35-0010N91527-34-0009N91528N91524-38-0011N91525-36-0011MaterialSpecificationIncludingTypeorGradeASTHA351Gr.CF8HASM,"SA105ASTHA458Gr.651ASTMA458Gr.651ASMESA193Gr.B6ASMESA193Gr.B6ASTHA276Te440CAS."IESA637Gr.718
i 0
I 0


12;02/9209:2950S3843152CROSBYVALVEEX(ic.SpringK60807-80-0011d.Boltinge.OtherPartssuchasPilotComponentsBonnetStudBonnetNutSerialNo.oridentificationHX3108-0016810622370MaterialSpecificationincludingTypeorGradeASMESAl93Gr.87ASMESA194Gr.28Vlecertifythatthestatementsmadeinthisreportarecorrect.Date19M~SignedCrosbyValve6GaSeCo.ByManufacturerCertificateofhuthoriaationNo,1878expiresSetember301989CERTIFIChTEOFSHOPINSPFCTIONI,theundersigned,holdingavalidcommissionissuedt%theNationalBoardofBoilerandPressureVesselInspectorsandtheStateorprovinceofandemployedbyArkwrihtMutualInsuranceComanhaveDateinspecceceequpmentdescribe!nthisataReporton19andstatethattothebestofn:yknov:ledgeandbelief.theManufacturerhasconstructedthisequip.mentinaccordancewiththeapplicableSubsectionsofhSMF.Sectiontll.'Bysigningchiscertificate,neithertheInspectornorhisemployermakesanyivacranty,ex.pressedorimplied.concerningtheequipmentdescribedinthisDataReport.Fur!hermore,neithercheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropercydamageoralossofanykindarisingfromorconnectedwith(hisinspection.FactoryMutualSystemCommisstons(Inspector)NationalBoard.State.ProvinceandNo.>
DATE:    02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE      7 REVISION:       0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
PSL-1,NIS-2TRACKINGNO.SL-2-7-~012FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsof'heASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:V3466(MarkNumber)(c)CodeClass:24.(a)IdentificationofSystem:SafetyInjectionDate:12/30/92Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;.2702WO&#xb9;:92002640CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A.(a)ApplicableConstructionCodeANSIB31.7,1969Edition.Addenda:N/A.CodeCase:NA(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1980Editionthruwinter19806.IdentiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)DiscInsertDiscInsertNozzleNozzleSpindleSpindleCrosbyCrosbyCrosbyCrosbyCrosbyCrosbyN89531-38-011N89431-42-020N90557-35-013N90557-38-022K55444-37-019K55444-48-033NANASA479Type316ASTMA-479Te316SA479Type316SA479Te316SA479Te316SA479Te3161979Replaced1992Replacement1979Replaced1985Replacement1979Replaced1991Replacement7.DescriptionofWork:Replaceddisc8nozzleduetoleakage.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)xOther:VTIVT2xVT3~pstgTestTemp~'F PSL-2,NIS-2TRACKINGNO.SL-2-7-~012FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryleakagetestwasperformedandwitnessedbyaVT2certifiedinspector.10.InspectionReportNumbers:M92-1538APPLICABLEMANUFACTURESOATAREPORTSTOBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairxReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedwnerorOwnr'sDesignee,TitleData~aa,19p~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightInsuranceofNorwoodMass.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;7startingon06/92,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspsctor'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorseRIentsDate-Iz
CLASS 'I CAEPBL STATUS COMPONENTS RIZER H  I  0 ZONE NUHBER:   2-005                      ASME                                    ONGT SEC. XI                                  RSEH


PSL2,NIS2TRACKINGNO.8L.2.p7~ayFORMVIS-2OWNER'SREPORTFORREPhlRSORREPLACEMENTSAsRequiredbytheProvlafonsoftbeASMECodeSectionXl1.Owner.2.Plant:FloridaPower4,LightCo.P.O.Box529100Miami,FL33152St.LucicPlant6501SouthHwy.AlAJensenBeach,FL349573.cworkPerformedBy:FloridaPower8cLightCo.6501SouthHwy.A1AJcnscnBeach.FL349574.ldcntificationofSystem:PQ5t'R855URfa8ROs~:CIPPts-Shcct:1of&Unit>>;2PO.>>;qgq9Q-98O&0PCM>>:4//tPWO>>:~/8XA>>:</jg8090Be30-/ddrPACW0>>:Bg+QProcessSheet:$~8-/yy/4'zRepairOrf,anizadonP.O.No.,JobNo.,eet.TypeCodeSymbolStampN/AAuthorizationNo,N/AExpirationDateN/A5.(a)ApplicableConstructionCodeASMESecuonill,1977Edition,Summer1977Addenda.~CodeCases(b)ApplicableEditionofSectionXlUtilizedf'rRepairsandReplacementComponents1980Edition,thrutheWinter1980addenda.~CodeCases6,IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponent(Id9.5gg'~NameofManufacturerQOMSO&2ldyyJCnJ6ra6'CRwlhManufacturerSerialNo.NationalBoardNo.OtherYearIdentificationBuiltH6'kfnlO.fZ+Z6ReplacedASMERepairedCodeorStampedReplacement(YorN)kPth~eitlrN0CaGARI0NutClLM&tP22<0ysJfdhld&dknlUk8N'tO.ff"l't4kPVLKHHurN07.DescriptionofWork:IHPC85rOOSAHQ68/tRrdA5vugg'Pf-AMGM'M6PR855URtKGie'-NRnJ5/flY.8.TestsCendusted:Hydtostatte~PneutnatteOtherPressureNominalOperatingPressureps'estTem.'F PSL.2,NIS2TRACKINGNO.SL~2~07.~DFORM'HIS-2(Sack)Sheol2ofW9,Remarks.Qf)gf565&gNg~ggMwlC<g~CRPl8DAfiitEJ~I~+@p~+~ggNgggh@JeerrgWASL8IffRoCSf/PA.Q.KACUTEA~neo.eP>PSC8Vl-Z.WeSfar-f-Oa~eaOAj~Pe.~O~8.APIsLICASLSMAHVCACTV%'tOATARSPORISTOSSATTACh4OCertificateofCompliancewecenitythailheslalsmenlsmadeinthereparlarecarrealandthisQRspairQReplacemenlconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:NIACertificaleofAuthorizationNo.:NIASignedOwnerorOwnerDesoo,Titl~O,ts4.It"1i293CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoiierandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightfnsuranceofNorwoodMass,haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle407startingon'b(2t3andstatethattothebestofmyknowledgeandbelief.theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.BysigningthiscerlificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedinlheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableInanymannerforanypersonalinjuryorproperty:damageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSlgrIalureCommissionsNationalBoard.Stato,ProvidenceandEndorsementsDaleD~
==SUMMARY==
C~14J~~~~~~~~~~~~~~~~I.~~0~~I~~~~~~~~~~~.~I~~~~rar~~~~~~~~'~~~~~~~~s.~~~~~~II~It~~~~~'~~I~~~~I~~Ii~~~'ll~~':I.st~.~r'I~~~~~,I~~~.~I~~~~~r~.~~~~'LrrI~SR'HMH%MRHMH.ggL'RRxA~:~~o~~~A~.~~:,~
EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUMBER    IDENTIFICATION                  ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK<<>>
PSL.2,NIS2TRACKINGNO.SL-2~09.~OIFORMNIS-2(Sack)Sheet2of&9.Remarks:LQg(I068f'GP.f-af.'/IE~~75M'(F~IC1(OUt'.APKCASLSLiH4UfAClUAE'SOATA22EPOATtTOOSArTsLCHisOCertificateofCompltanceWeoehttythatIhestalemenlsmadeInthereportarecorreolandlhtsQRepatr@JRsplaoemenlconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAutho'ionNo.:N/ASignedOwnororOwner'seslgno,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightfnsuranceofNorwoodMass.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleNO'7startlngon.'5)95andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivomeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.BysigningthiscertiTicateneithertheInspectornorhisemployermakesanywarranty,expressedorImplied,concerningIheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithortheinspectornorhisemployershallbeliableInanymannerforanypersonalinjuryorproperty:damageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sStgnatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDateC' e
REF. DWG. NO. 02-005-8 020300    MS-01                            8-G-2     VT 1        M95-368            X  - - - 11/15/95 - VI'-1 complete, examined 20 MANWAY STUDS                    87.20                                            studs, examination performed by  QC personnel 020400    MN-01                            8-G-2    VT-1        M95-368            X  - - - 11/15/95 - VT-1 complete, examined 20 MANWAY NUTS                      87.20                                            nuts, examination performed by  QC personnel REF. OWG. NO. 02-005-A 020500    501-671                          8-8       UT 0        NDE 5.1-21        X  - - - 10/21/95 - UT  complete UPPER HEAD TO UPPER SHELL        82.11    UT 45      HDE 5 ~ 1-22      X---
PSL-1,NIS-2TRACKINGNO.SL-2-8-~001FFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152StLucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:V09119(MarkNumber)(c)CodeClass:23WorkPerformedBy'loridaPower&,LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:AuxFeedwaterDate:7/28/94Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:0074WO&#xb9;:94010469CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASMESEcrIII1974/SuMMEtt76AooCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalSerialorHeatBoardNo.No.OtherYearIdentificationBuiltReplacedASMECodeRepairedStampedor(YorN)ReplacementPipePLug1/2"PipePlug1/2"PacificValveTiogaPipeCaitolMf.Heat&#xb9;2F3720NAASMESA105ASMESA1051991ReplacedReplacement7.DescriptionofWork:REPLACE1/2"PIPEPLUGFORVALVEDUETOLEAGAGEFROMPIPETHREADS.LINE&#xb9;I-4-BF-298.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VTI'T2XVT3~petgTeetTemp.~'F
UT 60      HDE 5.1-23        X---
UT 70      NDE 5.1-24        X---
                                                                                            <<*UT-4A**
0   101-622.A                       8 8      UT 0        NDE 5.1-21        X  - - - 10/21/95 - UT  complete UPPER SHELL  LOHGITUDIHAL WELD'2.12        UI'5       HDE 5.1-22        X-9 0 DEG.                                   UT 60      NDE 5.1-23        X---
UT 70      HDE 5.1-24        X---
                                                                                            **UT-4A**
WATER SPACE NOZZLES REF. DWG. HO. 02-005-8 022000    672-102                          LER      VT-1        HDE 4.1-'17        X  - - - 10/9/95 - VT-1 complete, no evidence of TEMPERATURE NOZZLE  9 0 DEGREES  93-04                                            leakage I-1-RC-130 REF. DWG. NO. 02-005 022100    V-1437                          PRZ IHC  VT-1        HDE 4.1-24        X  - - - 10/9/95 - VT-'I cerpiete INSTRUMENTATION VALVE            AUG-1


PSL-2,NIS-2TRACKINGNO.SL-2-0-~001FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM94-1080APPLCABLEMANUFACTURESOATAREPORTSTOBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignednerOwner'sDesignee,TitleDateIZ,19~9CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sIgatureCommissionsNationalBoard,State,ProvidenceandEndorsementDate PSL-1,NIS-2TRACKINGNO.SL-2-8-002FORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:02/07/96Sheet:1of2Unit:2P.O.&#xb9;:NY422537PCM&#xb9;:N/ANPWO&#xb9;:8218WO&#xb9;:95032001-01WCD&#xb9;:'N/A4.(a)IdentificationofSystemCCW(b)ComponentIdentificationVALVETCV-14MB(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:5.(a)ApplicableConstructionCodeandAddenda:ASME1974S1974ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearReplacedASMECodeBuiltRepairedorStampedReplacement(YorN)VALVE-30"SA516WR70VALVE-30"SA516-GR70STUDS-SA19311/4-8UN2ANUTS-SA19411/44UN2BHENRYPRATTCO.HENRYPRATTCO.ALLIEDNUTANDBOLTALLIEDNUTANDBOLTD0095-1-1D0095-1-262413E97187N/AN/AN/AN/AN/ARIR&#xb9;3K-0347&3RB-1430RIR&#xb9;2J-0232RIR&#xb9;2J47611979REPLACED1979REPLACEMENT1994REPLACEMENT1993REPLACEMENTYESYES7.DESCRIPTIONOFWORK:VALVEREPLACEMENTPERDISPOSITIONOFSTAR950764.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]VT3[]NominalOperatingPressure(ISLT)[X]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HDURs PSL-1,NIS-2TRACKINGNO.SL-2-8-002FORMNIS-2(Back)Sheet2of9.RemarksISLTWASSATISFACTORILYPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:M95-452APPLICABLEMANUFACTURER'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwner'ssignTitleDate+ICERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwnei'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsJDate 0
Jl DATE:   02/23/96                                  ST. LUCIE NUCLEAR PLANT UNIT 2                                     PAGE:      8 REVISION:       0                              INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
glC)rocatnyCI)kotl.CO)Ycortto<<)c)CloseCcL)to)(eat!gta<<PY)ttCtttylf)ClalCttt.'tt)CRSLe."yAI:LpOIITtUltl'UCllhllI'Uf57305Vf:VC'efsAeetoireaflayltctco)rhinosotatscASttCCoafrSects)etLLC)slsr.)aeasILRL<<sJ~AencMLbhietette)CSLy3))Cm))XCCC.CO..9RP:pethSC5)a>a,g~JATO)If<<or<<eon)5!))Cresset'ICertstacrtcttnlCke)7.Leo&riteStoaXloTLetoJ'os:ep..(.J5R)ttCa...SJ.<<ltsc5pUcaacCrnJ~)p'a~ee<raeve~temsesee~)~lwegtlS,CO4$O'Ielf<<are"r"nXOX~P<<reC~XPXi&tsreaevraurnrc.nccrI;o.~rc.~rtL~S.~r"~tS4e~g".')Icode)ttoCt)ttCeetlPecoteHut<<Ice'slc)Cosset~.So)cartNXScat<<IRct)ttownocTypeMcsttc).~ase))a~I'eeai-eIIse-siiil0}"A".Cq)IA1979gi~LC~~~sLrvetvyn)ctSyotcrawp0r)ySI)''rg~<<vs<<I~~~LCcocnCceaef)Constv<<ceo<<actttc~e~vel)LColt'Lt~afpreSSaeeeZZ$palOC%OS.Ltycssasrep<oXnyfarces~+~~v~~i<<~'s~~~~~\<<vv>>sauaae-e)~~)t.rLttoLtsttA1Socc.NewlouOctaRcenoetsKLt'.~I~ciiafr...,a<<Jl.Cth)littVSLS"ha1'1"i~t)30\~~~4)Catt~no<<a<<<<Le~rs'-e~~ic~~~~a.Nr~~s'';Ta~eh)elft1~.<<lie<<lah.tifL~aven.'T5<<~stu)s-incte~taeo!'[QJfig!s'1~c~a'<<n5ae~ie~i,sessL's%'e'sCtlleens)no&I.cpcect~li.~soPg.~~~~1Siiltlea~i11~i'Ihafar)1tabbI<<,lt~Ie-1rearoose'.nasgLesscafpr'talltlIsrICIO)1lt5Jtref<<sana,InntrekansI,7~raeSe~teu'srtvAspasnlasaa'area<<Iencols~tvrt,matllta<<lslhraIa1~nrIree~Ias1nnsst<raf1!assisI'as~"so<<fastIa,i<<at1'Ives1itlv.,Rl~~~~~.'~~'aah,~~~,~1~''ll''
CLASS  1 CAEPBL STATUS COMPOHENTS RIZER N I   0 ZOHE NUMBER:   2-005                    ASME                                      ONGT SEC. XI                                  RSEH
0  
~>>~'htse'LN1f0}.st.e'seIlast-)t.l,i<<IMf<eo.taL~~,4I.flic/IrrtrLI.I.SISl>>CIIJlB~g<<trsCoveraatt8/!l'}3C:W.BIS.CInel1lL~lr'4~ThurPlnSCSSTraystrIep~thr.is><<fyMech<<5fl(sF~<<ld~ctI<<gEhherPa<<ssB<<s<<I~She)TS/SIIelt~eecI'!>lb1,;t.FgSA'7'snhnsI"'~ChiJ'nesee>>beets."Hl'.II/IlclleeleIISSAIssgl<a%10lth'eh>>SteelslTeLQ!CClsyegaBgt~CfsvOC<<ss)1e.~>>421cs.I>>cc;:c.~oCKR)IFCATtCFCO)IVI.tWMSV'}yeeelstycehsetehestsetl-crrssneer4.'.;-ss~araawcccanlf>>seSL5p;~ee<<hsee.coffcsrnseaaerusesotyes:-'I<<~I<<>>'ttlrcccc>>ee>>QIcc0.Iff<<~lc~Acct>>*esw<<Ills.cc>>eee.I4>>.~Cfes<<set5'dne<<)Dtfsty..f!attCwhttrsc<<ef'LIssssesp<<esQp<<shscce.hf'caseofpfaaariA.tfN<<hJblsilseusestfe'lssn+eee~csverypa".3LfneOnCCMTFff-.fl)fe)s)4}Paasfa))aeth3/1bstorrner~OnfdeasereT'cattCo4O)S~'.h)and~h,Queo~caTf,~ff)lec~>>tcesscccycehleecyccc~QI'I.Ser':CC>>cy>>CCIC>>chefye&ehececaltcs>>Mc-soys.-&SIBSt/escen@'jt5ch>>fagdbf(})tcscscI///ISyr.e/h..I!)Bb}nehrrsnetrs.tubed.LMrhsmso1}y.~~\~~s:ER)lFIC'!YE<<CSIIG>LISPS)ION'4)Isheundessusnehhhah.".rgausIfc"1encl}stunfshuedhpthetfIt:c<<LSIgo:rdat'ogerasstptsshureVesselbifpe.toes~ndsheSssseorl'IIs<<frLcoA)).L!'LolNendeneltotedby-V..~..ISLT~AJf;QeOt~lar1}rc~7e~nnallsieIn}peel>>dttfaNufrp<<}rTthedceclchef411ttl5OssatfcpcetSbuC<<edShiepunlffhOr>>S'biOCecsfJsreShiththehgh'bCOde,SehtO<<SO.f}yI/gn>>fgsh}sersri(eCS}tnefhl'1thertcshfheetnrrurHscnpfcyermslesallyhysirSntPCSPfceStdorbeIF}et<<er~3thee<<tufpment<<frserihed'InOIISOaeaArpole.Futthercner4,neitherthetnt1>>>>crornerhisenchfeyeschilbe14h'et<<1Snfmannertcranyprecech.dtn,uryOrpl.qiutyItamrgeOraIa.SCfenySendenSnffteemOrCernededSn}'hfhftfnfpest}<asf..>~X:-I)~>.(jistt.'shi~'8/tr.r'er+>vs.rSDI..c'e}nile'esbslss++gaglic~.~I'frlrlnrnel<<less,ssarl'll PSL-I,NIS-2TRACKINGNO.SL-2-8-~003FFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plank3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AlAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:07/12/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2032WO&#xb9;:91026981CWO&#xb9;:NAProcessSheet:N/A4.(a)IdentificationofSystem:Chemical3VolumeControl(b)ComponentIdentification:V2328(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:25.(a)ApplicableConstructionCodeandAddenda:ASMESEGT.Ill74EDinow/NoADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalOtherBoardIdentificationNo.YearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)ReliefValveReliefValveCrosbyValveN59200.00-0003CrosbyValveS/NN59200.00-0005SA351CFBM(BODY)SA351CFSM(BODY)Replaced1988Replacement7.DescriptionofWork:Replacechargingpump2Creliefvalveduetobodytobonnetleak8.TestsConducted:Hydrostatic~Pneumatic,NominalOperatingPressure(ISLT)XOther:VTIVT2XVT3~psigTestTemp.~'P


PSL-2,NIS-2TRACKINGNO.SL-2-8-~003FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MMg544gAPPLICABLEMANUFACTURE'SOATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepair+XReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned4ukg~uIOwnor0r'sDesignee,TitleDate19t%CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsaridcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsF&#xb9;0NationalBoard,State,ProvidenceandEndorsementsDate19~4 PSL-1,NIS-2TRACKINGNO.SL-2-8-~008FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ReactorCoolant(b)ComponentIdentification:V2345IMsrkNemrrer)(31reNljgIl7-0s-r0Dre)I(c)CodeClass:2Date:06/28/95SheeL'of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:0236WO&#xb9;:94013291CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASMESFcrIII1974EomowNoAooEwoACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalOtherSerialorHeatBoardIdentificationNo.No.YearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)DiscInsert2x3/600psigDiscInsert2x3/600psigCrosbyVaiveCrosbyValveS/NN89431-38-0012S/N89431-43-0024NASA479Te316SA476Te311974Replaced1993Replacement7.DescriptionofWork:Replacediscduetoleakage,valvesenttostoresforuseasspare.S/NN59197-00-00018.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)X.Orher:VT1VT2VT3~psIgTestTemp.~'F
==SUMMARY==
EXAMINATION AREA                CATGY      EXAM                          E  I 0 E REHARKS NUMBER    IDENTIFICATION                ITEM HO    METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
REF. DWG. HO. 02-005-B 022200    HA1 THRU HA4                  LER        VT-'I      HDE 4.1-19        - - - X 10/9/95 - VT-1 complete, white substance HEATER PEHETRATIONS            93-04                                              found on vessel near heater penetration A3, not boric acid STEAM SPACE NOZZLES REF. DWG. NO. 02-005-B 022300    672-105A                      LER        VT-1        NDE 4.1-23        X  - - - 10/16/95 - VT-1 complete LEVEL NOZZLE 9 0 DEGREES      93-04 022350    672-105A                      B-E        UT 60      NDE 5.22-13        X  - - - 10/23/95 - UT  complete NOZZLE TO VESSEL WELD  9 0    84.13 DEGREES
                                                                                            *~UT-62, Ul'-70**
0  672-105B                      LER        VT-1        NDE 4.1-22        X  - - - 10/16/95 - Vl'-1 complete LEVEL NOZZLE 8 180 DEGREES    93-04 022450    672-1058                      B.E        UT 60      NDE 5.22-13        X  - - - 10/23/95 - UT  complete NOZZLE TO VESSEL WELD 9 'IBO  B4.13 DEGREES
                                                                                            *~UT 62) UT-70**
022500    672-105C                      LER        VT-1        NDE 4.1-21        X  - - - 10/16/95 - VT-1 complete LEVEL NOZZLE B 195 DEGREES    93-04 022550    672-105 C                      B-E        UT 60      NDE 5.22-13        X  - - - 10/23/95 - UT  complete NOZZLE TO VESSEL WELD  9 195  B4 ~ 13 DEGREES
                                                                                            "*UT-62( UT-70**


PSL-2,NIS-2TRACKINGNO.SL-2-8-~008FORMNIS-2(Back)9.Remarks:Q~@do>VW-KM~%pQP&rnhgg,.Sheet2of2'0.InspectionReportNumbers:II/t,IVI,C,Q-(QQAPPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceJWecertifythatthestatementsmadeinthereportarecorrectandthisRepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedsg.PnerrOwner'sDesignee,Titlerv-t6Datelt,19~SCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspecor'sSignatureCommissions1FCom&#xb9;60NationalBoard,State,ProvidenceandEndorsements1992 PSL-1,NIS-2TRACKINGNO.SL-2-8-~013FFORMNIS-ZOWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:CHG-PP-2B(MarkNumber)3WorkperformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:Chemical8VolumeControlDate:12/12/94Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2089WO&#xb9;:94029274CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:25.(a)ApplicableConstructionCodeandAddenda:ASMESecttll1971EDmowW72ADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplaccmcntComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalOtherSerialorHeatBoardIdentificationNo.No.YearBuiltReplacedASMECodeRepairedStampedor(YorN)ReplacementStuffingSoxStuffingBoxUnionPumpUnionPumpSNN732246-602SN33760813300Ht&#xb9;530467607SA479Gr410SA479.Gr41019741985ReplacedReplacementN7.DescriptionofWork:Replacestuffingboxassemblyduetoleakage.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~013FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.,10.InspectionReportNumbers:MMg4-20g4APPLCABLEMANUFACTURESDATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSCCA+V(S(pe1eDc1-1S,19~7OwnerOwn'esignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissions7m&#xb9;NationalBoard,State,ProvidenceandEndorsementDate eePSL-g,NIS-2TRACKINGNO.SL-2-8-~010FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957Date:2/9/95Sheet;1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NA3.WorkPerformedBy:FloridaPower&,LightCo.6501SouthHwy.AlAJensenBeach,FL34957(b)ComponentIdentification:MD-IA-15-R1(MarkNumber)(c)CodeClass:24.(a)IdentificationofSystem:INSTRUMENTAIRPWO&#xb9;:2488WO&#xb9;:95003025CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:,NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalSerialorHeatBoardNo.No.OtherYearIdentificationBuiltReplacedASMECodeRepairedStampedor(YorN)ReplacementHANGER(U-BOLT)BERGEN-PATERattHANGER(U-BOLT)BERGEN.PATERCNNAPART&#xb9;6500RIR&#xb9;3AF-4708NANAREPLACEDREPLACEMNN7.DescriptionofWork:REPLACEUBOLTWHICHWASFOUNDMISSING.LINE&#xb9;2-IA-758.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)Other:VTIVT2VT3X~pstgTestTemp.~'P PSL-2,NIS-2TRACKINGNO.SL-2-0-~010FORMNIS-2(Back)Sheet2of29.Remarks:VT-3PERFORMEDBYQC-EXAMINATIONOFU-BOLTINSTALLATIONONLY(SL-2-8-015)10.InspectionReportNumbers:MM95088APPLCABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis/RepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedwor0er'sDesignee,TitleDate~<I,t9~lCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonal.injuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSigatureCommissions&#xb9;NationalBoard,State,ProvidenceandEndorsementsDate
DATE:   02/23/96                                  ST. LUCIE NUCLEAR PLANT UNIT 2                                     PAGE:     9 REVISION:       0                              INSERVICE INSPECTION RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 1 CAEPBL STATUS COMPOHENTS RIZER H  I  0 ZONE NUMBER:   2-005                    ASME                                    OHGT SEC. XI                                  RSEH


PSL-1,NIS-2TRACKINGNO.SL-2-8-~017FORMNIS-2OWNERtSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:LCV-2110P(MarkNumber)3.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:Chemical6VolumeControlDate:06/22/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:015-295MPWO&#xb9;:2549WO&#xb9;:95003598CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:25.(a)ApplicableConstructionCodeandAddenda:ASMESEc1'III1971Eomm/W72AooCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)Spindle/Plug2"/1500lbSpindle/Plug2"/1500lbControlComonentsIncControlCIncHeatNo606083HeatNo4SA479GR316SA479SA316Stellite61992Replaced1995Replacement7.DescriptionofWork:Replacestem/plugassemblywhichwasfounddamaged8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VTIVT2XVT3~pstgTestTemp.~'3
==SUMMARY==
EXAMIHATIOH AREA                CATGY      EXAM                          E  I 0 E REHARKS NUMBER    IDENTIFICATION                ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
STEAM SPACE NOZZLES REF. DWG. NO. 02-005-B 022600  672-105D                      LER      VT-1       NDE 4.1-20        X  - - - 10/16/95 - VT-1 canplete LEVEL NOZZLE 9 345 DEGREES    93.04 022650  672-105D                      B-E      UT  60      NDE 5.22-13        X  - - - 10/23/95 -  UT complete NOZ2LE TO VESSEL WELD 9 345    84.13 DEGREES
                                                                                          **UT-62, UT-70**
WATER SPACE NOZZLES REF. DWG. NO. 02-005-B 022700  684-108A                      LER      VT-'I      HDE 4.1.16        X  - - - 10/9/95 - VT-1 cceplete, no evidence of LEVEL NOZZLE 9 0 DEGREES      93-04                                            leakage BOTTOM HEAD 022800  684-1088                      LER      VT-1        NDE 4.1-18        X  - - - 'ID/9/95 - VT-1 co@piete, no evidence of LEVEL NOZZLE 9 180 DEGREES    93-04                                            leakage BOTTOM HEAD


PSL-2,NIS-2TRACKINGNO.SL-2-0-~017FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-419APPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned0Ownor0er'sDesignee,TitleData~27,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'signatureCommissions1m&#xb9;NationalBoard,State,ProvidenceandEndorsementsDateI19CS
I I f
  'l t
ly
 
DATE: 02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:    10 REVI SIGH:      0                              IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS R COOLANT  PIPING LOOP B FROM RPV TO SG-2B N  I  0 ZONE NUMBER:  2-007                    ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION                  ITEM HO  METHOD      PROCEDURE          C G M R  **CALIBRATIOHBLOCK**
I-42-RC-123 REF. DWG. NO. 02-007 024300  RC-123-201-258                  8-J      MT          NDE 2.2-28        X  - - - 10/18/95 - MT complete, 10/19/95 - UT NOZZLE EXTEHSIOH TO ST.        B9.11    UT 45      NDE 5.2-36        X  - - - complete GEHERATOR NOZZLE                          UT 60      NDE 5.2-36        X.  --
                                                                                          **UT-4A**
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:    11 REVISION:      0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COHPONENTS R COOLANT  PIPING LOOP B SG-2B TO RCP-2B1 N  I  0 ZONE NUHBER:  2-010                    ASHE                                      ONGT SEC ~ XI                                  RSEN SUHHARY EXAHIMATION AREA                CATGY      EXAH                          E  I 0 E REHARKS NUHBER  IDENT IF ICATION                ITEM NO  HETHOD      PROCEDURE          C G H R  ~*CALIBRATION BLOCK**
I-30-RC-121 REF. DWG. NO. 02-010 027200  RC-121-401-258-8                B-J        MT          NDE 2.2-29        X  - - - 10/18/95 - HT complete, 10/19/95 UT ST. GENERATOR NOZZLE TO NOZZLE 89.11      UT 45      NDE 5.2-37        X  - - - complete, limited examination from the EXTENSION                                  UT 60      NDE 5.2-38        X  - - - nozzle side due to its configuration
                                                                                            **UT 6~*
028600  RC-121-107-742.LS.A            8-J        PT          NDE 3.3-43        X  - - - 10/19/95 - PT complete, 10/20/95 - UT ELBOW LONGITUDINAL SEAH        B9.12      UT 45      NDE 5.4-68        X  - - - complete, examined area next to weld UT 60      NDE 5.4-69        X  - - - RC-121-1501-771-B A*UT 028700  RC-121-107-742-LS-8            8-J        PT          NDE 3.3-43        X  - - - 10/19/95 - PT complete, 10/20/95 - Ul' ELBOW LONGITUDINAL SEAM        B9.12      UT 45      NDE 5.4-68            - - - complete, examined area next to weld UT 60      NDE 5.4-69        X  - - - RC-121-1501-771-B
                                                                                            **UT 6**
0  RC-121-1501-771-8              B-F        PT          NDE 3.3-43        X---    10/19/95 - PT complete, 10/20/95 - UT ELBOW TO SAFE END              85.130    UT 45      NDE 5.4-66        X---    complete, limited examination on the UT 45      NDE 5.4-67        X---    safe-end side due to its configuration UT 45      NDE 5.4-68        X---
UT 60      NDE 5.4-69        X---    **UT-59) UT-6**
028900  RC-121-4                        8-J        PT          NDE 3.3.43        X-      10/'19/95 - PT complete, 10/20/95 - UT SAFE-END TO REACTOR COOLANT    89.11      UT 45      NDE 5.4-65        --X-    complete, inside surface geometry, PUMP  281                                  UT 45      NDE 5.4-66        X-      limited examination due to weld configuration, examined from the safe-end side only
                                                                                            **UT 59k*
 
0 DATE: 02/23/96                                          ST ~ LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:      12 REVI SION:      0                                  IHSERVICE INSPECTION RESULTS FOR THE SECOHD  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS R COOLANT    PIPING  LOOP B FROM RCP-2B1    TO RPV N  I  0 ZONE NUMBER:  2-011                        ASME                                      ONGT SEC. XI                                  RSEN
 
==SUMMARY==
EXAMINATION AREA                      CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENT I F I CAT ION                  ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIOHBLOCK**
I-30-RC-121 REF. DUG. HO. 02-011 029100  RC-121-5                            8-J      PT          HDE 3.3-41        X  - - - 10/18/95 - PT coapiete, 10/20/95 -  UT REACTOR COOLANT PUMP 281      TO    89.11    UT 45      HDE 5.4-70        - - X -  complete, inside surface geometry SAFE-END                                      UT 45      NDE 5.4-72        X  --
                                                                                                **UT 59**
029200  RC-121-901-771                      B-F      PT          NDE 3.3-41        X---    10/18/95 -  PT complete, 10/20/95  UT SAFE-END TO PIPE                    85.130    UT 45      NDE 5.4-71        X--      complete UT 45      NDE 5.4-72        X---
UT 60      NDE 5.4-73        X---
UT 45      NDE 5.4-74        X---    **UT-59, UT-6~*
029300  RC-121-103-722-LS-A                  B-J      PT          NDE 3.3-41        X  - - - 10/18/95 - PT complete, 10/20/95 - UT PIPE LOHGITUDIHAL SEAM              B9.12    UT 45      NDE 5.4-74        X  - - - complete, examined area next to weld UT 60      NDE 5.4-73        X  - - - RC-121-901-771
                                                                                                **UT 64*
029400  RC-121-103-722-LS-B                  8 J      PT          HDE 3.3-41        X  - - - 10/18/95 - PT complete, 10/20/95 - UT PIPE LONGITUDINAL SEAM              89.12    UT60 AXIAL HDE  5.4-73        X  - - - complete, examined area next to weld UT45 CIRC NDE  5.4-74        X  - - - RC-121-901-771
                                                                                                **UT 64*
 
1 1
L 1
0
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION:      0                                IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS A1 SAFETY INJECTION  PIPING  INSIDE  O'TMT N  I  0 20NE NUMBER: 2-021                        ASME                                    OHGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENT IF I CATION                ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
I-6-SI-516  REF. DWG. NO. 02-021 046200  V-3258                            B-M-2    VT-3        NDE 4.3-97        X  - - - 10/23/95 - VT-3 complete VALVE INTERNAL SURFACE            B12.50
 
DATE:    02/23/96                                  ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE    14 REVISION:        0                              INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 1 CAEPBL STATUS COHPONENTS A2 SAFETY INJECTION PIPING  INSIDE CTMT N  I  0 ZONE NUMBER:    2-022                    ASME                                    ONGT SEC. XI                                  RSEN SUHMARY EXAMINATION AREA                CATGY      EXAH                          E  I 0 E REMARKS NUMBER    IDENTIFICATION                  ITEH NO  METKOD    PROCEDURE          C G M R  <<*CALIBRATION BLOCK**
I-12-RC-154 REF. DUG. NO. 02-022 05'1300  V-3217                        8-G-2      VT-1      NDE 4.1-33        X  - - - 11/1/95 - VT-1 complete, 11/6/95 - 18 CHECK VALVE BOLTING            87.70      VT-1      MM95-1692          X  - - - studs and nuts examined in place, examination performed by QC personnel 051400    V-32'l7                        B-H-2      VT-3      NDE 4.3-108                11/1/95 - VT-3 complete, uear located at VALVE INTERNAL SURFACE        B12.50    CNR        95-2-006                    valve and disk seat area, bottom and sides of bearing block housing, seat lapped and new disk  installed
 
    'l I
9      4 ~.
            'I II
 
DATE:  02/23/96                                      ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:    15 REVISION:      0                                  IHSERVICE INSPECTION RESULTS FOR THE SECOND  iNTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS B2 SAFETY INJECTION PIPING    INSIDE CTMT N  I  0 ZONE NUMBER:  2-024                        ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                    CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENT IF ICATION                  ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
1-12-SI-151 REF. DIIG. HO. 02-024 058100  V-3644                            8-G-2    VT-1        NDE  4.1-30        X  - - - 10/30/95 - VT-1 complete, 18 studs and GATE VALVE BOLTING                87.70                                            nuts examined 058300  SI -151-Fll-1                      8-J      PT          NDE  3.3-57        X--      10/30/95  PT and UT complete, root VALVE V-3644 TO PIPE              89.11    UT 45      NDE  5.4-98        X--      geometry,  limited examination from the UT 45      NDE  5.4-99        X--      pipe side due to the weld configuration UT  60      NDE  5.4-100      --X
                                                                                              **UT 354*
058420  SI -4203-581A                      F-A      VT-3        HDE  4.3-107      X  - - - 10/30/95 - VT-3 complete RIGID FRAME SUPPORT                F1.10 1-6-SI-518    REF. DWG. HO. 02-024 00  V-3261                            B-G-2    VT-1        HDE  4.1-31        X  - - - 10/30/95 - VT-1 complete, 16 studs and CHECK VALVE BOLTING                87.70                                            nuts examined 058900  SI-518-Fu-1                        B-J      PT          HDE  3.3-57        X  - - - 10/30/95 -  PT and UT complete, root VALVE V-3261 TO PIPE              89.11    UT 45      HDE  5.4-94        X  - - - geometry UT 45      NDE  5.4-95        X---
UT  60      NDE  5.4-96            X-UT 70      NDE  5.4-97            X-  ~*UT-38**
1-12-S1-151 REF. DMG. NO. 02-024 059740  S1-4203-67                        F-A      VT-3        HDE  4.3-106      - - -  X 10/30/95 - VT-3 complete, 11/8/95 - VT-3 Spring Support                    F1.50    VT-3        NDE  4.3-'112      X  - - - re-examination complete after adjust CNR        95-2-005 STAR        951638 PMO        8222 NO          95013842
 
P P g,
      +    4
        ~ t      I
              'ff 0
 
DATE: 02/23/96                                        ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:    16 REVI SION:        0                                IHSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS B2 SAFETY INJECTION PIPING    INSIDE CTMT N  I  0 ZONE NUMBER:    2-024                      ASHE                                      ONGT SEC. XI                                  RSEH SUHHARY EXAMIHATION AREA                  CATGY      EXAH                          E  I 0 E REMARKS NUHBER  IDENTIFICATION                    ITEH HO  HETKOD      PROCEDURE          C G H R  <<<<CALIBRATION BLOCK**
I-12-SI-151    REF. DMG. NO. 02-024 060100  SI-4203-71                        8-K-1      PT          HDE 3.3-57        X  - - - 10/30/95 - PT complete, examined 8 INTEGRAL ATTACHHENTS              810.10                                            integral attachments on the accessable    3 sides 060400  S I -151- FH-4                    B-J        PT          HDE 3.3-57        X  - - - 10/30/95 - PT and UT cceplete, root PIPE TO VALVE V-3247              B9.11      UT 45      NDE 5.4.98        X  - - - geometry, limited examination from the UT 45      HDE 5 '-99        X  - - - pipe side due to the weld configuration UT 60      NDE 5.4-100        - -  X-
                                                                                              *<<UT-35**
 
l Ll
  =r    I
 
DATE:    02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:      17 REVISION:        0                                INSERVICE INSPECTION RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS ED PRESSURIZER  SPRAY LINE N  I  0 ZONE NUMBER:    2-025                      ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUMBER    IDENTIFICATION                  ITEM HO  METHOD      PROCEDURE          C G M R  **CALIBRATIOHBLOCK**
I-4-RC-103 REF. DWG. HO. 02-025 063140    SPS-787                          F-A      VI'-3      HDE 4.3-96        X  - - - 10/21/95 - VT-3 complete RIGID STRUT                      F1.10 063600    RC"103C-SW-1                    8-J      PT          HDE 3.3-45        X  - - - 10/20/95 - PT complete, 10/23/95 -  UT Pipe to Tee                      89.11    UT  30      HDE 5.4-62        X  - - - complete UT 45      HDE 5.4-64        X---
UT 60      NDE 5.4-63        X-
                                                                                            ~~UT-40**
063700    RC-103C-SW-3                    8-J      PT          NDE 3.3-45        X---    10/20/95 - PT complete, 10/23/95 -  UT Reducer to Tee                  89.11    UT  30      HDE 5.4-62        X---    complete UT 45      HDE 5.4-64        X--
UT  60      NDE 5.4-63        X--
                                                                                            **UT-40**
0  RC-'I03C-SW-2                    8-J      PT          NDE 3.3-45        X  - - - 10/20/95 - PT complete, 10/23/95  UT Tee to Pipe                      89.11    UT  30      NDE 5.4 59        X  - - - complete, root geometry UT 45      NDE 5.4-60        --X-UT 60      NDE 5.4-61            -X-
                                                                                            **UT 40**
063900    RC-103-FW-903                    8-J      PT          NDE 3.3-45        X  - - - 10/20/95 - PT complete, 10/23/95 -  UT PIPE TO SAFE-END                89.11    UT  30      HDE 5.4-62        X  - - - complete UT 45      NDE 5.4-64        X-  --
UT  60      HDE 5.4-63        X.--
                                                                                            **UT 40**
064000    RC-504-671                      8-F      PT          NDE 3.3.45        X  - - - 10/20/95 - PT complete, 10/23/95  UT SAFE-EHD TO SPRAY NOZZLE        85.40    UT 45      NDE 5.4-77        X  - - - complete, counterbore geometry UT 45      HDE 5.4-78              X
                                                                                            **U'I-19**
 
I II I' C
 
DATE:  02/23/96                                      ST. LUCIE NUCLEAR PLANT UNIT 2                                      PAGE:  18 REVISION:        0                                  INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS
      .8 SHUTDOWN COOLING    LINE N  I  0 20NE NUMBER:    2-028                      ASME                                      ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                    CATGY      EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION                      ITEM NO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
I-12-RC-147 REF. DMG. NO. 02-028-A 074600  RC-147-1-SW-8                      B-J      PT          NDE  3.3-58        X---    10/31/95 -  PT and UT complete, root 3"  SllEEPOLET                      89.32    UT 45      NDE  5.4-101      X---    geometry UT 45      NDE'5.4-102        X---
UT  60      NDE 5.4-103        --X-
                                                                                              **UT 35**
I-10-RC-302 REF. DUG. NO. 02-028-B 076450  SI-4205-6408                        F-A      VT-3        NDE  4.3-109      ---X    11/2/95 - VT-3 complete, loose lock nut Spring Support                      F1.50    VT-3        NDE  4.3-111      X---    and incomplete thread engagement, CNR        95-2-007                    11/8/95 VT-3 re-examination complete PIS        8222                        after tightening MO          95013839 076500  SI-4205-6408                        8-K-1    PT          NDE  3.3-59        X  - - - 11/3/95 - PT coaplete, limited INTEGRAL ATTACHMENTS                810.10                                            examination due to hanger clamp, examined 3 accessible sides I-10-SI-130    REF. DUG. NO. 02-028-8 077600  SI-130-1-SN.6                      8-J      PT          NDE  3.3-61        X  - - - 1'I/14/95 - PT complete 2" BRANCH CONNECTION              89.32 I-3-SI-191    REF. DUG. NO. 02-028-A 080700  SI-191-FW.3                        8-J        PT          NDE  3.3-58        X  - - - 10/31/95 -  PT complete PIPE TO VALVE V-3527              89.21 080900  SI -191- FN-2                      8-J        PT          NDE  3.3-58        X  - - - 10/31/95 -  PT complete VALVE  V-3527  TO PIPE            89.21
 
I  II I '
I        I I,
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION:      0                                INSERVICE IHSPECTIOH RESULTS FOR THE SECOHD  INTERVAL, FIRST PERIOD, SECOHD OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS B SHUTDOWN COOLING    LIME N  I  0 ZONE NUMBER:  2-028                      ASME                                      ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY      EXAM                          E  I 0 E REMARKS NUMBER  IDENT IF I CATION                ITEM HO  METHOD      PROCEDURE          C G M R  **CALIBRATIOHBLOCK">>
I-3-SI-191  REF. DWG. NO. 02-028.A 081000  SI-191-1-S'W.1                  B.J        PT          NDE 3.3-58        X  - - - 10/31/95 - PT complete Pipe to Elbow                    89.21 081750  SI-4206-6361                      F-A      VT-3        NDE 4.3-110        X  - - - 11/2/95 - VT-3 coaplete RIGID STRUT    SUPPORT            F1.10
 
DATE:  02/23/96                                      ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION:        0                                INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS A SHUTDOWN COOLING    LINE N  I  0 ZONE NUMBER:  2-029                        ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATIOH AREA                    CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENT I F I CATION                ITEM HO  METHOD      PROCEDURE          C G M R  <<<<CALIBRATION BLOCK**
1-10-SI-127    REF. DWG. HO. 02-029-B 089300  V-3481                            8-M-2    VT.3        HDE 4.3-98        X  - - - 10/26/95 - VT-3 complete VALVE INTERHAL SURFACE            812.50
 
I l
I
 
DATE: 02/23/96                                      ST. LUCIE NUCLEAR PLANT UHIT 2 REVI SION:      0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS RIZER AUXILIARY SPRAY N  I  0 ZONE NUMBER:  2-030                      ASHE                                      ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY      EXAM                          E  I 0 E REMARKS NUHBER    IDENTIFICATION                  ITEM HO  METHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK~*
I-2-CH-146 REF. DWG. NO. 02-030-8 091600    CH-146 SW-1                    8-J        PT          NDE 3.3.49        X  - - - 10/23/95 -  PT complete VALVE SE-02-03 TO PIPE          89.21 091700    CH-146-SW-2                    8-J        PT          NDE 3.3-49        X  - - - 10/23/95 -  PT complete Pipe to Tee                    89.40 09'1900  CH-146-SW.4                    8-J        PT          NDE 3.3-49        X  - - - 10/23/95 -  PT complete Tee to Pipe                    89.40 092000    CH-146-SW-5                    8-J        PT          NDE 3.3-49        X  . . . 'IO/23/95 - PT complete 89.40 I-2-CH-347  REF. DWG. NO. 02-030-8 092100    CH-347-SW-1                    8-J        PT          HDE 3.3-49        X  - - - 10/23/95 -  PT cceyiete VALVE SE-02-04  TO PIPE        89.21 092200    CH-347-FW.2                    8-J        PT          NDE 3.3-49        X  . - . 10/23/95 -  PT complete Pipe to Tee                    89.40 I-2-CH-146 REF. DWG. NO. 02-030-8 092300    CH-146-FW.6                    8-J        PT          NDE 3.3.50        X  - . - 10/23/95 -  PT complete Tee to Pipe                    89.40
 
          ~ i 'I 1I L
~I
  ~
 
DATE:  02/23/96                                      ST. LUCIE NUCLEAR PLANT UNIT 2                                  PAGE: 22 REVISION:        0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVALED FIRST PERIODS SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COHPONENTS RIZER AUXILIARY SPRAY N  I  0 ZONE NUHBER:    2-030                      ASME                                      ONGT SEC. XI                                  RSEH SUHHARY EXAMINATION AREA                  CATGY      EXAH                          E  I 0 E REMARKS NUMBER    IDENT IF ICATION                  ITEH NO  HETHOO      PROCEDURE          C G M R  **CALIBRATIONBLOCK~~
I-2-CH-146 REF. DWG. NO. 02-030-8 092400  CH-146-S'W-7                      8-J        PT          NDE 3.3-50        X  - - - 10/23/95 - PT complete Pipe to Tee                        89.40 092500  CH-146-SW-10                      8-J        PT          NDE 3.3-50        X  - - - 10/23/95 - PT complete REDUCER TO ELBOW                  89.40 092600  CH-146-SW.9                        8-J      PT          NDE 3.3-50        X  - - - 10/23/95 - PT complete Elbow to Pipe                      89.40 092700  CH-146.SW-B                        8-J      PT          NDE 3.3-49        X  - - - 10/23/95 - PT complete 1                              89.40 092800  CH-146-FW-11                      8-J        PT          HDE 3.3-49        X  - - - 10/23/95 - PT co@piete Tee to Pipe                        89.40 I-2-CH-146 REF. DWG. NO. 02-030.
093760  CH-107-R7                          F.A      VT-3        NDE 4.3-104        X  - - - 10/27/95 - VT-3 complete VARIABLE SPRING BASE              F1.50 I-2-RC-149    REF. DWG. NO. 02-030-A 094600  RC-149-FW.2                      8-F        PT          NDE 3.3-47        X  - - - 10/20/95 - PT complete Pipe to Reducer                  85.140
 
E DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:    23 REVISION:      0                                IHSERVICE IHSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS B1 PRIMARY DRAIH N  I  0 ZONE NUMBER:  2-035                      ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION                  ITEM NO  METHOD      PROCEDURE          C G M R  ~*CALIBRATION BLOCK**
I-2-RC-122 REF. DUG. HO. 02-035 111200  RC-122.FN.1                      8-J      PT          NDE 3.3-42        X  - - - 10/19/95 - PT coagulate SAFE-EHD TO PIPE                B9.21 111800  2-RC-122-FB                      B-G-2    VT-1        NDE 4.1-26        - - -  X 10/19/95 - VT-1 coaplete, one bolt flush FLANGE BOLTIHG                  87.50    CNR        95-2-003                    with nut, acceptable per engineering evaluation JPH-PSL-88-070
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                PAGE: 24 REVISION:        0                                INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 1 CAEPBL STATUS COMPONENTS 82 PRIMARY DRAIN N  I  0 ZONE NUMBER:  2-036                        ASHE                                    ONGT SEC. XI                                RSEH SUHHARY EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUHBER  IDENT I F ICATION                ITEM NO  METHOD    PROCEDURE          C G H R  **CALIBRATIONBLOCK*"
I-2-RC-125 REF. OWG. NO. 02-036 112600  2-RC-125-FB                      B-G-2    Vr-1      NDE 4 ~ 1-25      X  - - - 10/19/95 - VT-1 complete FLANGE BOLTING                    87.50
 
1 k N  41 I h
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                  PAGE 25 REVISION:      0                                INSERVICE INSPECTION RESULTS FOR TNE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS  1 CAEPBL STATUS COMPONENTS N LINE FROH LOOP 281 N  I  0 ZONE NUMBER:  2-037                      ASHE                                      ONGT SEC. XI                                  RSEN SUHHARY EXAMI NAT ION AREA              CATGY      EXAM                          E  I 0 E REHARKS NUHBER  IDENTIFICATION                  ITEM NO  HETHOD      PROCEDURE          C G M R  **CALIBRATIONBLOCK**
I-2-CM-145 REF. DUG. NO. 02-037-B 116900  V-2516                                    VT-1        NDE 4.1-32        X  - - - 10/27/95 - VT-1 complete VALVE BOLTING
 
DATE: 02/23/96                                        ST. LUCIE NUCLEAR PLANT UHIT 2                                    PAGE:    26 REVI SION:      0                                  IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 1 CAEPBL STATUS COMPONENTS RIZER RELIEF LINE N  I  0 ZONE NUMBER:  2-038                        ASME                                    ONGT SEC. XI                                RSEM
 
==SUMMARY==
EXAMINATION AREA                    CATGY    EXAM                          E  I 0 E REMARKS NUMBER    IDENT IF I CAT IOH                ITEM HO  METHOD    PROCEDURE          C G M R  **CALIBRATIOHBLOCK**
I 4-RC-101 REF. DWG. HO. 02-038 119200  RC-506-671                          8-F      PT        NDE 3.3-46        X  - - - 10/20/95 - PT complete, 10/24/95  UT NOZZLE TO SAFE-EHD                  85.40    UT 45      NDE 5.4-75        X  - - - complete UT 45      HDE 5.4-76        X---
                                                                                              **UT-17
* I-3-RC-309    REF. DWG. HO. 02-038 120150  RC-4300-9                          F-A      VT-3      NDE 4.3-114        X  - - - 11/20/95 - VT-3 complete Spring Support                      F1.50 I-3-RC-310 REF. DWG. NO. 02-038 121550  RC-4300-70                          F-A      VT-3      NDE  4.3-1'13      X  - - - 11/20/95 - VT-3 complete Spring Support                      F1.50
 
DATE:    02/23/96                                      ST ~ LUCIE NUCLEAR PLANI'NIT 2                                      PAGE:  27 REVISION:          0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COMPONENTS UMP 2A DISCHARGE HEADER    PIPING N  I  0 ZONE NUMBER:    2-043                      ASME                                    OHGT SEC. XI                                RSEH
 
==SUMMARY==
EXAMINATION AREA                      CATGY    EXAM                          E  I 0 E  REMARKS NUMBER    IDENT IF I CAT IOH                  ITEM NO  METHOD      PROCEDURE        C G M R  **CALIBRATIOHBLOCK*~
I-6-SI-113    REF. DHG. NO. 02-043-D 138650    S I -2408-9                        F-8      VT-3        HDE 4.3-105      X  - - -, 10/27/95  - VT-3 complete RIGID  FRAME SUPPORT              F1 ~ 10 138800    S I -113- Fll-5                    C-F-1    PT          HDE 3.3-56        X  - - - '10/27/95 -  PT and UT coaylete, root ELBOM  TO ELBN                    C5.11    UT 45      HDE 5.4-92        X  - - - geometry UT  60      HDE 5.4-93        - - X-ttUT 38*%
'138900  SI -113-5-Ql-1                      C-F-1    PT          HDE 3.3.56        X  - - -  10/27/95 -  PT and UT complete, root Elbow to PIpe                      C5.11    UT 45      HDE 5.4-92        X  - - - geometry UT 60      HDE 5.4.93        - -  X-
                                                                                                **UT-38**
SI -113-FH-6                        C-F-1    PT          NDE 3.3-56        X  - - -  10/27/95 -  PT and UT complete, root PIPE TO PENETRATION 36              C5.11    UT 70      HDE 5.4-90        X - - -  geometry UT 45          5.4-91        X -  --
UT 45 NDE NDE 5.4-92        X -  --
UT  60      NDE 5.4-93        - - X -  **UT-38**
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UHIT 2                                    PAGE:    28 REVISION:      0                                IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COMPONENTS INJECTION PIPING TO SI TANK 2A2 N  I  0 ZONE NUMBER:  2-045                      ASHE                                    ONGT SEC. XI                                RSEH
 
==SUMMARY==
EXAMINATION AREA                  CATGY    EXAM                          E  I 0 E REMARKS NUHBER  IDENT IF ICATION                  ITEM NO  METHOD    PROCEDURE          C G M R  **CALIBRATIOHBLOCK>>>>
I-6-SI-113  REF. DUG. NO. 02-045 168400  S1-4200-322C                      CC        PT        HDE 3.3-55        X  - - - 10/26/95 - PT complete, examined 8 INTEGRAL ATTACHMENTS              C3.20                                            integral attachments, no examination fran one side due to support clamp
 
DATE:  02/23/96                                  ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:    29 REVISION:      0                              INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COHPOHENTS COOLING HEAT EXCHANGER 2A N  I  0 ZONE NUHBER:  2-055                ASHE                                      ONGT SEC. XI                                    RSEH SUHHARY EXAMINATION AREA            CATGY        EXAM                          E  I 0 E REMARKS NUMBER  IDENTIFICATION              I TEH  HO  HE'THDD    PROCEDURE          C G M R  **CALIBRATIONBLOCK**
REF. DUG. HO. 02-055 209200  1-2701                      C-A          UT 45      NDE 5.2-39        X  - - - 10/27/95 - UT complete, limited FLANGE TO BODY              C1 ~ 10      UT  60    NDE 5.2-40        X  - - - examination due to nozzles and flange configuration
                                                                                        **UT-52**
209300  1-2702                      C-A          UT 45      NDE 5.2-39        X  - - - 10/27/95 - UT complete, limited BODY TO TUBESHEET          C1.30        UT  60    HDE 5.2-40        X  - - - examination due to nozzles and tubesheet configuration
                                                                                        +*UT-52*+
209500  1-2741-2                    C-B          HT        HDE 2.2-30        X  - - - 10/26/95 -  HT cceyiete PAD TO VESSEL              C2.31 0  1-2741-3                    CB          MT        HDE 2.2-30        X  - - - 10/26/95 - HT  complete PAD TO VESSEL              C2.31 209800  1-2742-2                    C-B          HT        NDE 2.2-30        X  - - - 10/26/95 - HT  complete PAD TO VESSEL              C2.31 209900  1-2742-3                    C-B          MT        HDE 2.2-30        X  - - - 10/26/95 - HT  complete PAO TO VESSEL              C2.31
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:    30 REVISION:      0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COHPONENTS EEDMATER TO SG 2A1  INSIDE CONTAINMENT N  I  0 ZONE NUHBER:  2-067                      ASHE                                    ONGT SEC. XI                                RSEH SUHHARY EXAMIHATION AREA                  CATGY    EXAH                          E  I 0 E REHARKS NUHBER  IDENTIFICATION                  ITEH NO  METHOD    PROCEDURE          C G H R  <<*CALIBRATION BLOCK~*
I-18-BF-51  REF. DMG. NO. 02-067 252100  BF-4007-6081                    C-C      HT        NDE 2.2-27        X  - - - 10/16/95 - HT complete, one integral INTEGRAL ATTACKHENT              C3.20                                            attachment examined
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION:      0                                  INSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COHPONENTS EEDNATER TO SG 281  INSIDE CONTAINHENT N  I  0 ZONE NUMBER:  2-068                      ASHE                                    ONGT SEC. Xl                                RSEN SUMHARY EXAHINATION AREA                  CATGY,    EXAM                          E  I 0 E REMARKS NUHBER  IDENTIFICATION                  ITEH  NO  HETNOD    PROCEDURE          C  0 H R **CALIBRATIONBLOCK*>>
I-18-BF-52  REF. DUG. NO. 02-068 255300  BF-4006-6076                    C-C        HT        NDE 2.2-26        X  - - - 'IO/16/95 - MT complete INTEGRAL ATTACHHENT              C3.20
 
DATE:    02/23/96                                      ST. LUCIE HUCLEAR PLANT UNIT 2                                    PAGE:      32 REVISION:          0                                IHSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF) ~
CLASS 2 CAEPBL STATUS COMPONENTS ED  HPSI DISCHARGE H  I  0 ZONE NUMBER:    2-087                      ASME                                    ONGT SEC. XI                                  RSEH
 
==SUMMARY==
EXAMINATION AREA                    CATGY      EXAM                          E  I 0 E REMARKS NUMBER    IDENTIFICATION                    ITEM NO    METHOD    PROCEDURE          C G M R  **CALIBRATIONBLOCK~*
I-3-SI-179    REF. DWG. NO. 02-087-A 361250    SI-2416-352                        F-8        VT-3      HDE 4.3-99        X  - - - 10/24/95 - VT-3 complete ANCHOR                            F1 ~ 10 361300    S I -2413-352                      C-C        PT        NDE 3.3.54        X  - . - 10/24/95 - PT  complete INTEGRAL ATTACHMENTS              C3.20 I-3-SI-179    REF. DWG. HO. 02-087-B 364100    S I -179- FW-910                  C-F-1      PT        NDE 3.3-53        X  - - - 10/24/95 - PT  complete, 10/25/95 -  UT Pipe to Elbow                      CS ~ 21    UT 45      NDE 5.4.85        X  - - - complete UI'0      NDE 5.4.89        X  - --
                                                                                              **3-SS-160..434.22**
SI-179-8-SW-1                      C-F-1      PT        HDE 3.3-53        X  - - - 10/24/95 - PT complete, 10/25/95  UT Elbow to Pipe                      C5.21      UT 45      NDE 5.4-85        X - - - complete, root geometry UT 60      HDE 5.4-86        - - X-
                                                                                              **3-SS-160-.434-22*
365200    SI -179-FW-10                      C-F-1      PT        NDE 3.3-53        X  - - - 10/24/95 - PT complete, 10/25/95 UT PIPE TO PENETRATIOH 69            C5.21      UT 45      NDE 5.4-85        X  - - - complete, inside surface geometry UI'0      HDE 5.4-87        X -  --
UT 60      HDE 5.4-88        - - X-
                                                                                              **3-SS-160-.434-22**
I-2-SI-109    REF. DWG. NO. 02-087-C 365300    SI-109-F'W-1                      C-F-1      PT        HDE 3.3-52        X  - - . 10/24/95 - PT complete, 10/25/95 -  UT Reducer to Pipe                    C5.21      UT 45      NDE 5.4-82        X  - - - complete, root geometry UT 60      NDE 5.4-83        X  - --
UT 70      NDE 5 '-84        - -  X-
                                                                                              **2-SS-160-.342-20**
 
DATE:  02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:    33 REVISION:      0                                INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COMPONENTS ED HPSI DISCHARGE N  I  0 ZONE NUMBER:  2-087                    ASME                                    ONGT SEC. XI                                RSEN, SUMHARY EXAMIHAT ION AREA                CATGY    EXAM                          E  I 0 E REMARKS NUHBER  IDENTIFICATION                  ITEM NO  METHOD    PROCEDURE          C G M R  **CALIBRATIONBLOCK~*
I-2-S1-109  REF. DWG. NO. 02-087-C 365400  Sl-109-SM-2                      C-F-1    PT        NDE 3.3-52        X  - - - 10/24/95 - PT  complete PIPE TO VALVE HCV-3647          C5.30 I-2-SI-215  REF. DWG. NO. 02-087-J 375600  SI-215-FM-2                      C-F-1    PT        NDE 3.3-51                X 10/24/95 - PT complete, one acceptable Reducer to Pipe                  C5 ~ 21  UT 45      NDE 5.4-79        X--      round indication, 10/25/95 - UT UT 60      NDE 5.4-80        X--      coapiete, root geometry UT 70      NDE 5.4-81        --X
                                                                                          **2-SS-160-.342-20**
 
DATE:    02/23/96                                    ST. LUCIE NUCLEAR PLANT UNIT 2                                    PAGE:  34 REVISION:        0                                IHSERVICE INSPECTION RESULTS FOR THE SECOND  INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)
CLASS 2 CAEPBL STATUS COMPOHENTS NG PUMP  2A DISCHARGE TO AUX  MPSI H  I  0 ZONE NUMBER:    2-088                      ASME                                    ONGT SEC. XI                                RSEH
 
==SUMMARY==
EXAMINATION AREA                    CATGY    EXAM                          E  I 0 E REHARKS NUMBER    IDENTIFICATION                    ITEM NO  METHOD    PROCEDURE          C G M R  ~*CALIBRATIOH BLOCK**
I-2-CH-104 REF. DWG. HO. 02-088-B 381625    CH-104-FII.600                    C.F.1    PT        QCR MM95-1817      X  - - - 11/13/95 - PT complete, examination PIPE TO VALVE V-2169              C5.30                                            performed by QC personnel 38'l660  V-2169                                      N/A        N/A                        11/11/95 - Valve Has replaced CHECK VALVE 381675    CH-104-FM-601                    C-F-1    PT        QCR MM95-1817      X  - - - 11/13/95 - PT complete, examination VALVE  V.2169  TO PIPE            C5.30                                            pe'rformed by QC personnel
 
St. Lucie Unit
  ~
        ~    ~
2                            L-96-72 Docket No. 50-389 Fall 1995  Refueling Outage NIS-1  ATTACHMENT 2 1995 EDDY CURRENT     
 
==SUMMARY==
REPORT
 
Page1 of 1 FORM NIS BB OWNERS'ATA REPORT FOR EDDY CURRENT EXAMINATIONRESULTS As required by the provisions of the ASME CODE RULES EDDY CURRENT EXAMINATIONRESULTS PLANT: St. Lucle Unit 2 EXAMINATIONDATES: NOVEMBER 1, 1995 through NOVEMBER 9, 1995 TOTAL                TUBES        TUBES        TOTAL TOTAL            INDICATIONS            PLUGGED AS    PLUGGED      PLUGGED STEAM          TUBES                                    PREVENTIVE      THIS        TUBES GENERATOR      EXAMINED        20% - 39%  40%  100%    MAINTENANCE    OUTAGE          IN S/G 8142          231                                                      274 8213          152                                                      209 LOCATION OF INDICATIONS (20% - 100%)
U BENDS        EGGCRATES          PARTIAL SUPPORTS      TOP OF TUBE SHEET STEAM                              1TO7                  8 AND 9          TO 41 EGGCRATE GENERATOR      DHB to DCB        H/L    C/L            H/L      C/L            H/L        C/L A            222            2        6            3        2            1          0 B              143          2        3 Remarks:
S/G 'A': (1) ONE TUBE PREVENTIVELYPLUGGED DUE TO MRPC EZI INDICATION.
S/G 'B'REVENTIVELYPLUGGED TUBES INCLUDE:
(2) THREE TUBES PLUGGED DUE TO CORROSION DAMAGE IN Tl S SLUDGE PILE REGION FOUR TUBES PLUGGED FOR FLAWS SHOWING WEAR PROGRESSION AT DIAGONALS (3)
AND (1) VERTICALSTRAP (VS2)
DATE:        Zo    PK          PREPARED BY:
G E      CU  ENT COORDINATOR DATE'ATE'EVIEWEDBY:                                  I  SPECTIONS SUP RVISOR REVIEWED BY:
S/8 TE      NICALS ECIALIST fcnns lUhiabbsO.~
 
0
                "            L j
            'L n "l
') P a g )    I,    4<    4
          ~      g    1q
 
CUMULATIVE DISTRIBUTION
 
==SUMMARY==
 
ST LUCIE UNIT P 2 10/95 COMPONENT :  STG gA                                    Page : 1 Date : 11/16/95 Examination Dates    :  11/02/95  thru 11/09/95 Total  Number  of Tubes Examined                8142 Total Indications Between  20% and 39:                        231 Greater than or equal to 40:                  5 Total Tubes Plugged as Preventive Maint Total Tubes Plugged >= 40%
Total Tubes Plugged from MRPC Examination for Top of Tubesheet Indication Total Tubes Plugged This Outage.........:
Location Of Indications    204  to 100%
Hot Leg                          Cold Leg TSH .5  to  01H -2.1        1  TSC .5  to  01C -2.1 01H -2.0 to  07H +2.0        2  01C -2.0 to  07C +2.0 07H +2.1 to  DHB -3. 1        3  07C,+2.1 to  DCB  -3.1 DHB -3.0 to  DCB -3. 0    222
 
CUMULATIVE DISTRIBUTION
 
==SUMMARY==
 
ST. LUCIE UNIT 8 2 10/95 COMPONENT :  STG gB                                                    Page : 1 Date : 11/16/95 Examination Dates    :  11/01/95      thru 11/09/95 Total  Number of. Tubes Examined                                8213 Total Indications Between 204 and      39%                                    152 Greater than or equal to 404                                  4 Total Tubes Plugged as Preventive Maint Total Tubes Plugged ) 40 o        ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~  ~ ~
Total Tubes Plugged from MRPC Examination for Top of Tubesheet Indications Total Tubes Plugged This Outage
* Note:    Tube 69-83 was plugged due to a bobbin coil response of 434 9 TSH +0.6. This tube also showed a pluggable "I" code (ASI) at the same  location.
Location Of Indications            204    to    100>
Hot Leg                                      Cold Leg TSH .5  to  01H  -201          6      TSC .5          to  01C -2.1 01H -2.0 to  07H  +2.0          2      01C    -2.0 to        07C +2.0 07H +2.1 to  DHB  -3.1          2      07C    +2.1 to        DCB -3.1 DHB -3.0 to  DCB  -3  0      143
 
INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COHPONENT    : STG fIA                                                                                          Page DESCRIPTION : 20% TO 100%                                                                                        Date : 11/16/95 Time : 08:38:52 I              I Extent                          I                  10/95                                  N/A IRowl LinlLeglReqlTst/Hotel    Reel    Probe          Location    IvoltslDeglch      I %  IDiffl Location lvoltslDeglch  I % I
+---I --- I--- I-- I-------I-      I              I I 891  211  H ITECITEC PSIAH070  IA-580.H/ULC  IVS2      .7    I      71    II 21 221 as/  221  H ITEGITEc    IAH070  IA-580.H/ULC  IVS3    - 7          1.sl      IP zl I
I 901  241  H ITECITEC PSIAH070  IA-580.H/ULC  IVS3    -.6      I      61    II 21  211 I 611      I H ITECITEC PSIAHOS    IA-580-M/ULC  IVS4            I      61    II zl  221 I 921  261  H ITECITEC PSIAH093  IA-580-H/ULC  IVS3      .9    I    .61      I>>l    211    I I    I    I H  ITECITEC PSIAH093  IA-580.M/ULC  IVS4    .7      I    .71      II zl  231    I I    I    I H  ITECITEC PSIAH093  IA-580-M/ULC  105C  - 7          1.211321      11 271 I 881  281  H ITECITEC PLIAH066  IA-580-H/ULC  IVS3  -1.2            ~ 61    IP 21 231 I    I    I  H ITECITEC PCIAH066  IA-580-H/ULC  IVS4                  .sl      II zl  201 I    I      H ITECITEC PCIAH066  IA-580-M/ULC  IVS4                  .71      II 21  231 I 981 281    H ITECITEC PSIAH089  IA 80 H/ULC IVS                      .81      II 21  z61 I 811  291  H ITECITEC PSIAH089  IA-580-M/ULC IVS3      -.8                    IP 21 301 I    I    I H  ITECITEC PSIAH089  IA-580.M/ULC  IVS3                  .81      IP 21  zsl                I I    I    I H  ITECITEC PSIAH089  IA-580.H/ULC  IVS3    .8            .71      IP zl  231                I I    I    I H  ITECITEC PSIAH089  IA-580-H/ULC  IVS4  1.0            .71      IP 21 z41                  I I 961 301    H ITECITEC PCIAH066  IA-580 H/ULC  IVS2    1 '            .sl      IP 21 z11                  I I    I    I H  ITECITEC PCIAH066  IA-580-H/ULC  IVS4                  .sl      I>>I 201                    I I 981 301    H ITECITEC PSIAH089  IA-580 H/ULC  IV 2      .4          .51      II 21  zol                I 110sl 331    H ITECITEC PSIAH089  IA-580-H/ULC  IVS2                  .sl      IP zl zzl                  I I 921 341    H ITECITEC PCIAH066  IA-580.H/ULC  IVS4    -.4          1.21      II 21311                  I I 961 341    H ITECITEC PSIAH066  IA-580.H/ULC  IVS2    - 7 I
I s11 351    H ITECITEC PCIAH087  IA-580-H/ULC  IVS3    -.6            .71      IP 21  zsl                I I 881 361    H ITEGITEC PSIAH066  IA-580.H/ULC  IVS4    -.9                    II zl 221                  I 11011 371    H ITECITEC PSIAH089  IA-580.M/ULC  IVS3    1.8            .911391    11 211                  I I  11 391    C ITEHITEH PCIAC099  IA-560-SF/RH  ITSH    1.3            ~ 411331    11 301                  I I azl  441  C ITEHITEH PLIAC048  IA-580-M/ULC  IVS2      .8          ~ 91    li z13sl                    I 471  H ITECITEC PLIAH068  IA-580-H/ULC  IVS2    -.8          ~  sl    li 21 zol                  I I    I    I H ITECITEC  PCIAH068  IA-580-M/ULC  IVS3  -.6          F 01      li zl 291                  I I    I    I H ITECITEC  PCIAH068  IA-580-M/ULC  IVS4    .9            ~  91    IP 21  zel                I I  31 491 C ITEHITEH    PSIAC099  IA-560-SF/RH  102C    -.8          .71      II  21 221                  I 491  H ITECITEC PCIAH103  IA-580.M/ULC  IVS3    1 ~ 1        .61      IP 21 241                  I 751 491 C ITEHITEH    PSIAC053  IA-580.H/ULC  IVS3    - 3          ~  sl    IP 21 201 I                                                                                                            I I 481    01  C ITEHITEH PSIAC002  IA-580-H/ULC  IVS3    -.8          .sl      II  21 221                  I 501  H ITECITEC PSIAH068  IA-580.H/ULC  IVS1    1.0                    II 21 zzl                  I I    I    I  H ITECITEC PSIAH068  IA-580.M/ULC  IVS2  -.6          1.01      II zl 291                  I 11z61    Ol K ITECITEC  PSIAH091  IA-580-M/ULC  IVS1      ~ 9        ~  sl    IP 21  zsl                I I 781 521 C ITEHITEH    PSIAC048  IA-580-H/ULC  IVS4    -.8          hei      li 21311                    I 521 C ITEHITEH  PSIAC053  IA  80 M/ULC IVS2      - 7          ~  sl    II  21  zol                I I    I    I  C ITEHITEH PSIAC053  IA-580.M/ULC IVS3      .0          1.41      Ir  21 311                  I I    I    I  C ITEHITEH PGIAC053  IA 8 H/ULC IVS        -.6            ~  91    IP 21 241                  I 11261 541    H ITECITEC PSIAH091  IA-580.H/ULC IVS1        .9          .sl      II  21  zsl                I 491 551    C ITEHITEH    IAC003  IA-580.H/ULC IVS3      - 9          .81      IP 21 211                  I-I 11231 551 C ITEHITEH    PSIAC047  IA-580.M/ULC IVS1    -1.0          ~  41    II zl  201                I I
                                                - I-I  I    I
                                                                                          -I--
 
REPORT 100'NDICATIONS/TRENDING                    PSL-2 OUTAGE    : 10/95 COMPONENT      : STG fIA                                                                                          Page      2 DESCRIPTION      : 20K To                                                                                          Date : 11/16/95 Time : 08:38:56 I              I Extent      I                    I                  10/95                  I  I          N/A IRowlLinlLeglReqlTst/ kotel      Reel    Probe        Location      IvoltslDeglch        X  IDiffl Location Ivoltsloeglch  I X I
+      I    I
              ---I- -I-        I      I            I
                                                                        ---- I---I---I. I I
I131I 55I    C ITEHITEH    SCIAC051  IA-580 M/ULC IDCB        .0          .sl      Ii al  21I I 89I 57I    C ITEHITEH    PSIAC006  IA-SBO.M/ULC IVS2        .9                  Ii al  21I I 9sl 5rl    C ITEHITEH    PLIAC053  IA-SSO.M/ULC IVS2    -.8            .5I      Ii al  aol I129I 57I    C ITEKITEH    PSIAC047  IA-580.M/ULC IDCT        .0        .7I      Ii al  24I I 92I 58I    C ITEHITEH    PSIAC053  IA-580.M/ULC IVS4    1.0                    IP al  3ol I    I    I C ITEHITEH    PSIAC053  IA-580.M/ULC IVS4      ~ 2                    Ii al  34I I 96I 58I    C ITEKITEH    PSIAC053  IA-580.M/ULC IVS3    -.8            ~ sl    li al  as/
I 93I 59I    C ITEHITEH    PSIAC048  IA-580.M/ULC IVS4    -.6            ~ 5I    li al  24I I12rl 59I    C ITEHITEH    PSIAC047  IA 580 M/ULC IVS1    1.0            .sl      li al  23I I rel sal    C ITEHITEH    PSIAC052  IA-580 M/ULC IVS2    1.0            .Sl      li al  as)
I    I    I C ITEHITEH    PSIAC052  IA-580-M/ULC IVS3    .9            .sl      Ii al  23I I 96I sal    C ITEHITEH    PCIAC059  IA-580.M/ULC IVS3    -.7            ~ 5I    IP al  aol I 39I 63I    C ITEHITEH Sc    IAc003  IA-580-M/ULC IVS3    -1.0                    IP 2I  22I I 93I 631    C ITEHITEH    PSIAC      IA-580-M/ULC lvsa    -1 ~ 1          ~ 5 I    Ii al  aol 1133I 63I    C ITEHITEH    PSIAC      IA-580-M/ULC lvsi        .e          ~ rl    Ii al  23I I135I 63I    C ITEHITEH      IAC045  IA-580-M/ULC I09H        .9          .7I      Ii al  aal I    I    I  C ITEHITEH    islAco45  IA-580-M/ULC IVS1    -.8                      Ii al  31I I    I    I C ITEHITEH    PSIAC045  IA-580-M/ULC Ivsi    .9            .5I      IP al  aol I 94I 64I    C ITEHITEH    PSIAC052  IA-580 M/ULC Ivsa        .9        1.1I      II al  32I I    I    I C ITEHITEH    PSIAC052  IA-580 M/ULC Ivs3    .9                      Ii al  aal I 47I ssl    C ITEHITEH    sclAcoo3  IA 580.M/ULC lvs3    -.9            .9I      Ir al  aal C ITEHITEH    PSIAC039  IA-580.M/ULC lvsa    -.9                    IP al  aal I    I    I  C ITEHITEH    PSIAC039  IA-580.M/ULC Ivs4    -.9            ~ 9l    IP al  aal I 34I  sel  C ITEHITEH    PCIAC004  IA-580 M/ULC IDHB        .0                  Ii al  aal I eel  sel  C ITEHITEH    PSIAC032  IA-SBO.M/ULC lvsa    -.9            .7I      li al  23I I 35I  69I  C ITEHITEH    PCIAC003  IA-580.M/ULC IDCB        .0        1.5I      Ii al  ael                I      I  I 37I  69I  C ITEHITEH    PSIAC003  IA-580-M/ULC IDHB    - 3            .Sl      IP al  aol I                                                                                                              I      I  I I    I    I  C ITEHITEH    PSIAC003  IA-580-M/ULC I07c  25.o          a.ol      IP al  32I                I      I  I I 42I  rol  C ITEHITEH GNPLIAC060    IA-580-M/ULC IDCB        ~ 7      1.11      IP al  36I                I      I  I I 44I  rol  C ITEHITEH    PSIAcoso  IA-580 M/ULC Iocg        ~ 0        .5I      IP al  24I I 82I  7ol  C ITEHITEH    PSIAC032  IA-580.M/ULC Ivs3    -1.0          .7I I eel  rol  C ITEHITEH    PSIAC032  IA-580-M/ULC Ivsa    - 7          .sl      IP  al  aal I136I  rol  C ITEHITEH    PSIAC      IA-580 M/ULC IVS1    -.8          1.1I      Ii al  ael I    I    I C ITEHITEH    PSIAC045  IA-SBD.M/ULc Ivs3    - 7            .sl      Ii al  aol I 39I  71 I C ITEHITEH    PSIAC069  IA-580-M/ULC IDCB        .0        .sl      li al  aol I 41I  71I C ITEHITEH      PSIAC069  IA-seo-M/ULC IDCB        .0                  Ii al  aol I 43I 71 I    C ITEHITEH    PSIAC069  IA-580-M/ULC IDCB        .0        .7I      Ii al  21I I 45I 71I    C ITEHITEH    PSIAC069  IA-580-M/ULC I DC 8      .0        .9I      Ii al  23I I    I    I C  ITEHITEH    PSIAC069  IA-580-M/ULC IDCB    ~  0 79I 71I    C ITEHITEH    PSIAC039  IA-580 M/ULC IVS2    - 7          ~  7I    IP  al aol I
I 38I ral    C ITEHITEH GYPLIAC060    IA-580 M/ULC IDHB        ~ 0        .Sl      li al 31I I    I    I C  ITEHITEH    PSIAC060  IA-580 M/ULC IDCB    1.0            .7I      IP al arl I  40I  ral C ITEHITEH PLIAC060        IA-580 M/ULC IDHB        .0        1.ol      li al  33I
'---I--    I- --I--I------ -I-        I                                            I    I    I
 
IND I CAT IOHS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT    : STG O'A                                                                                                Page      3 DESCRIPTION : 20K TO 100K                                                                                              Date : 11/16/95 Time : 08:38:56 I              (
Extent      I                                          10/95                      I    I          N/A (Row( Lin(LeglReqlTst/ Note(    Reel      Probe      Location        (volts(oeg(ch          X (D i ff  Location  lvoitsloeg(ch  I X I
+-          I  I  I
                            -I-        I
(          (
                                                                                                            -- --------I----I. I--I"  +
I    I    I C ITEHITEH GNPLIAC060    IA-580-M/ULC (DCT      .0                      IP 2( 3s(
I 42( 72(    C ITEHITEH GNPLIAC060    IA-580-M/ULC IDHB        ~ 0      1.11        IP 2( 36(
I    I    I c ITEHITEH      IAC060    IA-580.M/ULC IDCT      .0                      (I 2( 24(
I  82( 21 C ITEHITEH      PSIAC032    IA-580-M/ULC IVS3      -.8                      (I 2( 22(
( 88( 721 C ITEHITEH  PSIAC032    IA-580-M/ULC Ivs3      1.0          ~ 7(      (I 2( 221 (126( 721 c ITEHITEH      PCIAC042    IA-580-M/ULC 109H        ~ 1        .411331        1( 24(
721 C ITEHITEH    PSIAC045    IA-580-M/ULC IVS1        .8          .6(        (I 2( ao(
(  43( 731    C ITEHITEH  PSIAC069    (A-580-M/ULC IDHT        .0          .6(        (p 2( ao(
I    I    I C ITEHITEH  PSIAC069    IA-580-M/ULC (Dce      ~ 0          .61        IP 2( ao(
(  491 731    C ITEHITEH  PSIAC069    (A-580.M/ULC (Bee        .0          ~ 71      IP 2( as)
I  55( 73(    C ITEH(TEH  PSIAC069    IA-580-M/ULC IDCB        .0                    (I 2( ao(
175( 73(      C ITEHITEH  PSIAC039    IA-580-M/ULC (VS3        ~ 9        .9(        (I 2( 22(
11351 731 c ITEHITEH      PSIAC045    IA-580-M/ULC (VS1        .8                    (I 2( 28(
I    I    ( C (TEH(TEH  PSIAC045    IA-580-M/ULC IVS3      .9            .61        IP 2( 21(
I    I    I c ITEHITEH PSIAC045      IA-580-M/ULC Ivs4    -.9            .91        (I 2( 26(
(  421 74( c ITEHITEH GYPLIAC060        IA-580-M/ULC IDHB        .0        2.61        (I 2( s3(
I C ITEHITEH  PSIAC060    IA-580-M/ULC IDCB      .0                      (P 2( 311 741 C ITEHITEH    PSIAC032    IA-580-M/ULC (vsa      - ~8        1.21        (I 2( 311
(  43(      I C ITEHITEH  PCIAC069    IA-580-M/ULC IDHB        .0                    (I 2( 321 I    I    I c ITEHITEH  PCIAC069    IA-580-M/ULC IDCT      .0          2.3 (        (I 2( 34(
I  451 75(    C (TEHITEH  PLIAC069    IA-580-M/ULC IDHT        .0        1.21        I    I as(
I    I    I C ITEHITEH  PSIAC069    IA-580.M/ULC IDCT      .0            ~ 91      Ii 2( 23(
751 C ITEHITEH    PSIAC045    IA-580 M/ULC IVS1        .9          ~ 61      (I 2( 21(
I  441  761 c ITEHITEH GNPL(AC060      IA-580-M/ULC IDHB        .0        1.2(        (I 2( 37(
771 c ITEHITEH    PSIAC069    IA-580 M/ULc IDGT        .0        a.o(        IP 2( 32(
(  S1( 77(    C ITEHITEH  PSIAC069    IA  80 M/ULC I CT        .0        2.11        (I 2( 33(
I 531 77( C (TEH(TEH      PSIAC069    IA-580-M/ULC IDHB        .0        1.61        (I 2( 3o(
I    I    I C ITEN(TEH  PSIAC069    IA-580-M/ULC IDCT      ~ 0          .8(        IP 2( 22(
1571 77(      C (TEH(TEH  PSIAC069    IA-580-M/ULC IDCT        .0        1.o(        II 2( 241
( 73( 771 C ITEHITEH  PSIAC039    IA-580-M/ULC IVS2      -.7                    (I 2( 211 I    I    I C ITEHITEH  PSIAC039    IA-580.M/ULC IVS2      .8          1.01        (p 2( 22(
(  so( 781    C ITEHITEH GNPLIAC060    IA-580-M/ULC IDHB        .0        1.11        IP al 3s(
(  72( 781    C ITEHITEH  SSIAC038    IA-580.M/ULC IVS4      -.5                      II 2( 3o(
(  961 781    C ITEHITEH  Ps(Aco61    IA 80 M/ULC  IVS3      -.9          ~ 9(      (I 2( as(
I  49( 791    C ITEHITEH  PS(AC069    IA-580 M/ULC IDHT        .0                    (I 2( 29(
I    I    I C (TEH(TEH  PS(AC069    IA 580 M/ULC  IV 3    -.9          2.21        II 21331 c ITEHITEH  PS(AC069    (A-580.M/ULC (VS3    -  2          F 81      II 2( 22(
I    I    I I    I    I C ITEHITEH  PSIAC069    IA-580-M/ULC  IDCT      ~ 0        1.S(        II 2( 291
(  S3( 79(    C ITEHITEH  PS(AC069    IA-580.M/ULC  IDHT        .0        .71    ,,
IP 21 211 791  C ITEHITEH  PSIAC069    (A-580-M/ULC  (DCB        .0        1.21        Ii a(    261 I  sa( 8O(    C (TEH(TEH GHPL(AC062    IA-580-M/ULC  IDHT        .0        1.71        (P 21    4s(
I    I    I C ITEHITEH GYPLIAC062    IA-580-M/ULC  IDCB      .0          1.7(        (p 2( 46(
S4( 801    C ITEHITEH  PSIAC062    (A-580-M/ULC  (DCT        .0                    IP 21 261 I---I- '
(                                                                                                        I                  I  I  I  I
+---(- --I --I-    I        I      -I    ---------I-                          I    -I  -
I
                                                                                                --I----I-                    I
 
INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT      : STG IIA                                                                                          Page      4 DESCRIPTION : 20/. To 100K                                                                                          Date : 11/16/95 Time : 08:38:56 I                I Extent      I                    I                  10/95                  I    I          N/A                  I IRoM) Lin)Leg)Req)Tst/ Note( Reel          Probe    )
Lo ca'tion    )Volts)oeg)ch      )
X  )Diff) Location  )volts)oeg)ch    )
x I
  +-          I    I    I        I-      I
                                                      .-I-  .  .- "---I----.I---I I- -I----I--- --------I-----I                ---)---+
I 62) 801    C  ITEHITEH GNPLIAC062  IA-SBO.M/ULC IDCB        ~ o    I    -9)    I>>I 34)        I          I      I 4    81)  C  ITEH)TEH  PSIAC071  )A-580-H/ULC  )OHB      .0                  )I 2) 21)
I    I    )
C  )TEH)TEH  PL)AC071  IA 580-H/ULC  )VS3    -.8          1.81      Ii 2) 3o)                          I I    I    I c ITEHITEH    PLIAC071  IA-580-H/ULc  IDGT      .0          2.71      Ii 21 361                          I I s3) 811    C  ITEHITEH  PSIAC071  IA.580-M/ULC  )oHB      .0        1.o)      Ii 21  22)                        I I    I    I c ITEH)TEH    PSIAC071  IA-seo-M/ULC  IDGT      .0          1.s)      II 2) ar)                          I I ss)  811  C  ITEHITEH  PSIAC071  IA-580-H/ULC  IDCT      .0        2.11      IP 2) 32)                          I I 73) e1) c )TEH)TEH          IAC041  IA-580-H/ULC  103C    -.6            .411361    11 251                          I I 501 821 C ITEHITEH        PSIAC062  IA-580-M/ULC  IDCB      ~ 0                  )p 2)  27)      I
  ) 6o) 821 c ITEHITEH        PCIAC062  IA-580-H/ULC  IDHB,      .0                  IP 2)  28)      I
  ) 541 841 C ITEHITEH        PSIAC058  IA-580-M/ULC  IDCT      ~ 0          ~ 91    )I 21  341      I I 49) 851 c ITEHITEH        PSIAC067  IA-580-M/ULC  IDHB      .0        1.7)      )p 2)  3o)      I' I    I    I  C  ITEHITEH GNPLIAC067  IA-580-M/ULC  IDCB    .0          2.7)    )I 2)  371
  ) S1) 851 c ITEHITEH        PSIAC067  IA-580-M/ULC  IDHB      .0        1.11      )I 2)  24)      I I    I    I  c  ITEHITEH  PSIAC067  )A-580-M/ULC  )DCB    .0          1 ~ O)    Ii 21241        I I  ss) 851    C  ITEHITEH  PSIAC067  IA-580 M/ULc  IDCB      ~ 0        2.11    )P 21 33)
~ /  57/ 851
  ) 56) 861 861 C
C ITEKITEH 851 c ITEHITEK I 541 861 C ITEHITEH C ITEHITEK PSIAC067 PSIAC041 ITEHITEH GYPLIAC058 PCIAC058
                              -PSIAC058 IA-580-M/ULC IA-580-H/ULC IA-580-M/ULC IA-580.M/ULC IA-580 H/ULC IDCB IVS4 IDHB IVS3 IDCB
                                                                  .0
                                                                -1.0
                                                                  ~ 1
                                                                -1.0
                                                                  ~ 0
                                                                                .4) 1.51
                                                                                .S)
                                                                                .8)
I>>I
                                                                                      )I
                                                                                      )I Ir
                                                                                      )I 2) 2)
2) 2)
261 ao) 43) as) 3o)
I
  )  se) 861    C  ITEHITEH  PSIAC058  IA-580.M/ULC  IDCB      .0          .61    )r  2)as)
  )  92) 861    C  ITEHITEK  PSIAC061  IA.580-M/ULC  IVS2      .7          .8)    )I 2) 23)
I    I    I  c ITEHITEK    PSIAC061  IA-580-H/ULC  IVS3    -.7          1.61    II 2) 32)
I    I    I  c ITEHITEK    PSIAC061  IA-580-H/ULC  IVS4    -.9            .61    )I 2) 21)
  )14o) 861      C  ITEHITEH  PSIAC045  IA-580-H/ULc  IDGT      .0        1 '1    )p 2)'34)
I 491 871      C  ITEHITEH  PLIAC067  IA-580.H/ULC  IDCT      .0        2.51    )I 2) 36)
  ) S1) 871 C  ITEHITEH  PSIAC067  IA-580-H/ULC  IDHB      .0    )
                                                                            '.1)      Ir 2) as)
I    I    I  c ITEHITEH    PSIAC067  IA-580.H/ULC  IDCT    .0                    IP 21 321
  )  SS) 87) C ITEH)TEH        PSIAC067  IA-580-H/ULC  IDHB      .0        1.2)    )I  21  as)
I    I    I  c ITEKITEH    PSIAC067  IA-580-H/ULC  IVS3    .8            .7)    )I  2)ao)
I    I    I  c ITEHITEH    PSIAC067  )A-580-H/ULc  IDGT    .0          1 ~ 11  II  21  as)
  )  s91 871 c ITEHITEH        PSIAC067  IA-580-M/ULc  IDHB      .0          .8)    )I 21  as/
I  931 e71 c )TEH)TEH        PS)AC      IA-580-H/ULC  IVS2      .8          .S)    )I 2)  221
  )  so) 881    C  ITEHITEH  Ps)Acose  )A-SBO-H/ULC )OCB        .0                  )p 2)  as)
I  941 88)    C  ITEHITEH  PC)AC      )A-580.H/ULC  )VS4    -.9            .S)    )p 2)  21)
I  47) 891    C  ITEHITEH GYPLIAC067  )A-580.H/ULC  )DHB      ~ 0                )P 21 48)
  )  S3) 891    C  ITEHITEH  PSIAC067  IA-580 M/ULC  IDHB      .0                  )p 2) as/
I    I    I  c ITEHITEH    PSIAC067  IA-580-H/ULc  IDGT    .0            .71    Ir 2) ao)
  )  951 891 C ITEHITEH        PLIAC061  IA-580-H/ULC  IVS4    1.2            .61    IP 2) as/
I  451 911 c ITEHITEH        PSIAC067  IA-580-H/ULC  IDHB      .0        1.31    Ir 2) 261 I    I    I  C  ITEHITEH  PSIAC067  IA-580-H/ULC  IDCT    .0          1.31    IP a) as/
471 911 C )TEH)TEH        PSIAC067  IA-580-H/ULC  IDHB      .0          .7)    II 21 ao)
                                                                                                                                  --I- '
  )                                                                                                                I      I  I    I  I
  +---I---I---I-        I        I
                                        -I---'---------I-                          I
                                                                                      -I---I---I---I-              -I- ---I    I
 
INDICATIONS/TRENDING REPORT PSL-2 OUTAGE    : 10/95 COMPONENT      : STG fIA                                                                                    Page  ~
5 DESCRIPTION : 20K TO 100/e                                                                                  Date : 11/16/95 Time : 08:38:56 I              I Extent    I                                        10/95                I              N/A                I IRowlLinlLeglReqlTst/ Hotel    Reel-    Probe    I  Location      lvoltslDeglch    I x IDiffl Location lvoltsloeglCh  I x I
'---I---I---I- I---- ---I                                          -I-----I---I--I---I--                                    +
1139l 91I    C ITEHITEH PSIAC045    IA  80 H/ULC IDHT      .0    I  1.al    II al asl                                  I I 45I 93I    C ITEHITEH PSIAC067    IA-580.M/ULC IDCB      .0          ~ rl          aol                                  I I  97I 93I    C ITEHITEH PSIAC056    IA-580-H/ULC IVS3      .9          .4I    lp al 22I                                  I 49I 9sl    C ITEHITEH PLIAC067    IA-SSO.H/ULC IVS3    - 7                    II al 26I I                                                                                                                            I I    I    I C ITEHITEH PSIAC067    IA-580 M/ULC IDCT    ~  0          1.2I    II al asl                                  I I  94I 96I    C ITEHITEH PBIAc056    IA-580-M/ULC IVS2      ~ ?          .5I    Ip al 26I                                  I I  4rl 9rl    C ITEHITEH PLIAC067    IA-SBO.H/ULc Ivs3      .8                  lp al 26I                                  I I    I    I C ITEHITEH PBIAC067    IA-580 M/ULC IDCB    .0              .Sl    Ir al 21 I                                  I I  s3I  9?l  C ITEHITEH    IAC067  IA-580-M/ULc I04c 26.2              .SI134I      29I                                  I I13sl    9?l  C ITEHITEH IslAco45    IA-580.H/ULc IVS3      .8          .6I          21 I                                I I134I    98I  C ITEHITEH PCIAC045    IA-580.H/ULC IVS3    - 3            .sl    I>>l aol                                    I I138I    98I  C ITEHITEH IslAco45    IA-580-H/ULC IDHT      .0        1.6I    Ir al                                      I H ITECITEC PSIAH082    IA-580.M/ULC IDCB      ~ 0                I>>l 22I                                    I I  45I 99I    H ITECITEC PSIAH082    IA-580-H/ULC IV 3      .8                  II al 22I                                  I I  4ol1ool    H ITECITEC PCIAH105    IA-580.H/ULC IVS3    -.8            .sl    II al 21 I                                  I 46I100I    H ITECITEC PSIAH105    IA-580-M/ULC IVS3    - 7            .Sl    II al 24I I                                                                                                                            I I  48I100I    H ITECITEC PCIAH105    IA-580.H/ULC IDCB      .~ 0          .6I    II al 22I                                  I I  54I1ool    H ITECITEC PCIAH107    IA-580-H/ULC IVS3      ~ 7          .6I    I>>I    26I                                  I I  31I1oil    C ITEHITEH PCIAC030    IA-580-H/ULc IDGT                          I>>l                                        I I  34I102I    H ITECITEC PCIAH105    IA-580-M/ULC IVS3      .8          .sl    lp al  21 I                                I I134I1oal    C ITEHITEH PCIAC045    IA-580-H/ULC IDCT      .0                  I>>l as/                                    I I 91I1o3I    C ITEHITEH PLIAC069    IA-580-H/ULC IVS4      ~ 9          .Sl    lp al 22I                                  I I 95I105I    C ITEHITEH PCIAC063    IA-580-H/ULC IVS3      ~9          .6I    II al  21 I                    I  I      I I 96I108I    C ITEHITEH PSIAC024    IA-580-H/ULC IVS2    -.9            .5I    II al                          I  I      I I    I    I C ITEHITEH PSIAC024    IA-580-H/ULC IVS3"  -.9              .7I    I>>I arl                        I  I      I I 101 I 109 I C ITEHITEH PSIAC023    IA-580-H/ULC IVS3    1.0            .sl    I>>I    21 I                    I  I      I I  aal11ol    C ITEHITEH SCIAC029    IA-580-H/ULC I03C  12.5                                                                I I 123 I 113 I C ITEHITEH  PSIAC018    IA-580.M/ULC IVS1    -.8            .4I    Ip al aol                                  I I    I    I C ITEHITEH    IAC018  IA-580.H/ULC IVS3    ~  7                  I>>l    aol                                  I I      I    I C ITEHITEH PSIAC018    IA-SSO.H/ULC IVS4  -.9              .6I    II al 22I                                  I I  4?I11sl    H ITECITEC PSIAH084    IA-580 H/ULC IVS    -.8            .7I    I>>l    23I                                  I I      I    I H ITECITEC PSIAH084    IA-580-H/ULC IVS3  1.0            .sl    I>>I    aol                                  I I127I117I      C ITEHITEH PSIAC023    IA-580-M/ULC IVS1      .8          .6I    lp al 22I                                  I I 84I12ol      C ITEHITEH PSIAC015    IA-580-M/ULC IVS4      .9          .6I    II al 21 I                                  I I 94I12ol      C ITEHITEH PSIAC023    IA-580-M/ULC lvsa      .8                  II al 26I I1oal12ol      C ITEHITEH PSIAC017    IA-580-M/ULC lvs3    -.8            .sl    II al aol I126I12ol      C ITEHITEH PCIAC035    IA-580-M/ULC IOSH  -1.3          1.ol    II al aol C ITEHITEH    IAC017  IA-580-H/ULC lose      .8          .6I    II al aal I  s3I12rl c    ITEHITEH PSIAC012    IA-580-M/ULC IVS3      .8          .Sl    li al arl I  91I12?l    C ITEHITEH PCIAC018    IA-580-M/ULC lvsa    -.9            .5I    II al as/                I I  9?I12?l    C ITEHITEH Ps IAC017  IA.580-H/ULC Ivs3      .8          .7I    II al 24I                I I  s4I128I    C ITEHITEH PSIAC011    IA-580-H/ULC IVS3      .8          .6I    II al aal                I I  8?I129I    C ITEHITEH SCIAC016    IA 58 H/ULc  Ivs3    -.8      I    ~  4I  Ip al aol    I          I I---I---I---I-- ----I-        I-          I
                                                    -------------I-          I  I  I    I-
 
INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT    : STG &#xb9;A                                                                                        page :    6 DESCRIPTION: 20K TO 100K                                                                                      Date : 11/16/95 Time : 08:38:56 I              I Extent IRoMILin(Leg(ReqlTst/Note(        Reel      Probe I  '0/95 Location      lvolts(Deglch      I I I Location N/A lvoltslDeglch    X
                                                                                                                                +
I
  --I--I-                                                              I- -I--I--I- (Diff(
I                                I  I I  I          I        I            I                                        I
                                                                                                                        ---I---+
I    I    I c ITEHITEH    PSIAC016  IA-580 M/ULC  lvs3              I  1  41    IP 2( 36(              I      I        I I  9311311  C  ITEHITEH    PSIAC023    IA-580.M/ULC IVS2      .9    I    -91    IP 21 26(              I      I        I I  5711331  C  ITEHITEH    Is Iacoiz  IA-580-M/ULC IVS3      -.6          .6(    IP 21 24(              I      I        I I  9711331  C  ITEHITEH    Ps IAC014  IA-580 M/ULC  lvsz              I    .71    IP 21 27(              I      I        I I  9611341 c ITEHITEH      Ps IAC013  IA-580.M/ULC  lvsz      .8    I    ~ 4(    IP 2( 20(              I      I        I I      I    I c ITEHITEH    Ps IAC013  IA-580.M/ULC  lvs3      .7      I    F 51    IP 2( 21(              I      I        I
(  96('138(  C  ITEHITEH    PS IAC013  IA-580.M/ULc  lvsz                  .6(    li 21  zzl            I      I        I I    I    I c ITEHITEH    Ps IAC013  (A-580 M/ULC  lvs3              I  1  1(    IP 2( 27(              I      I        I I  9 11391  C  ITEHITEH    Ps IAC014  IA-580.M/ULC  (VS2              I    ~ 4(    IP 2( 21(              I      I        I I  97(1391 c ITEHITEH      PSIAC013  (A-580-M/ULC  IVS2    -1.2          as(    IP 2( 24(              I      I        I I  481140( C ITEHITEH      PSIAC009  IA-580.M/ULC  IVS3      .8          .sl    Ip 21 22(              I      I        I I    111411 c ITEHITEH      PCIAC033  IA-560-SF/RM  (01H    24 '      I      7(142( 1( 20(                I      I        I I  85(141( c ITEHITEH      PSIAC013  IA-580 M/ULC  IVS3      .8            6(    Ip zl 21(              I      I        I I  8711431 c ITEHITEH          IAC014  IA-580.M/ULC  IVS2    -1 ~ 1          4(    IP 2( 211 I                        (          I      I        I I      I    I c ITEHITEH    PCIAC014  IA-580-M/ULC  IVS3      .4      I      sl    IP 2( 24(              I      I        I I  4911471 c ITEHITEK      PSIAC012  IA-580-M/ULC  IDCB      .O    I    .6(    II 21  zzl  I          I      I  I    I I  5611521  C  ITEHITEH    PSIAC014  (A-580-M/ULC  I vs3  -1 ~ 0    I            li 21 22(              I      I  I    I I  7411541  C  ITEHITEH    PSIAC013  IA-580.M/ULC  105H    26.1      I    .511331    11 301              I      I  I    I I  5711551 c ITEHITEH      PSIAC013  IA-580-M/ULC  IVS3      -.7          .6(    Ip 2( z1(              I      I  I    .I
(  51(157(  C  ITEHITEH    PSIAC014  (a-580-M/ULC  lvs3                          (I 2( 28(              I      I  I    I I    311591  C  ITEHITEH    PSIAC033  IA-560 SF/RM  103c      5.8    I    .511281    11 351              I      I  I    I
+      I    I    I  I          I      I            I
                                                        ------------I----.I---I- -I- -I----
Number    of  RECORDS, Selected from C urrent Outage        236 Number    of  TUBES  Selected from Cur rent Outage :    177
 
lND I CAT IONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  :~ STG ffe                                                                                            Page :    1 DESCRiPTION : 20K TO 100K~                                                                                        Date : 11/16/95 Tine : 08:40:03 I              I Extent        I                      I                    10/95                I  I          N/A                I IRo~l LinlLeglReqlTst/Notel      Reel      Probe    I  Location      I Volts l Deglch  I I Ioiffl Location IVoltslDeglch  I x, I
+-  I    I
            --I- I------- I-            I
                                                    -I----                          I    I    I -I I 54l 22I  C  ITEHITEH    PCIBC092    IA-580-M/ULC  IVS3                            li al  ael I Brl 23I  H  IIECIIEC    i SIBH1os    IA-580-M/ULC  IVS2        .7          .7I    Ii al  zol I 96l 24I  H  ITECITEC    PSIBH103    IA.580.M/ULC  I07H        ~ 2                lr al  asl I    I H  IIEGITEC    i sleH1os    IA-580-H/ULC  IOBH                            Ii zl  21I I    I H ITECITEG    PSIBH103    IA-580-M/ULC  IVS4    -.9          1.1I    lr al  asl I    I H ITECITEC    PCIBH103    IA 80 H/ULC  IDCB      .0                  Ii zl  zsl I 4sl 25I  c  ITEHITEH    PSIBC105    IA-580-M/ULC  IVS3      -.6            .6I    lr al  as/
I 94I 26I  H  ITEGITEC    PCIBH086    IA-580-H/ULC  IV 2                    .sl    Ii zl  aol I 96I 26I  H  ITECITEC    PSIBH103    IA-580-H/ULC  IVS4      -.8            .9I    Ii al  21I I 98I 26I  H  ITECITEC    PSIBH086    IA-580-M/ULC  IDCT        .0                  Ii zl  29I I1oil 27I  C  ITEGITEH        IBC106  IA-580-H/ULC  IDCT        .0          .7I    lr zl  24I Iiool 28I  C  ITEHIIEH    PSIBC096    IA-580-M/ULC  IDCT                            IP  al  34I I >>I  29I  C  ITEHITEH    PCIBC096    IA-580-M/ULC  IDCT        ~ 0          .3I    lr al  asl I >>I  29I  C  ITEHITEH    PCIBC096    IA-580-M/ULC  IDHB        .0          .3I    Ir  zl  asl I    I    I C  ITEKITEH    PCIBC096    IA-580-M/ULC  IVS1    - 7                    Ir  zl  26I I    I    I c ITEHITEH    PCIBC096    IA-580-M/ULC  IVS1      .8            .2I    IP  al  zil I    I    I c ITEHITEH    PCIBC096    IA-580-M/ULC  IVS2    1.0            ~ 4I  Ir al arl I c ITEHIIEH    PCIBC096    IA-580-M/ULC  IVS3    -.9            ~ 2I  Ir al 21I I C  ITEHITEH G NPLIBC096    IA-580-M/ULC  IVS3    1.0                    Ir al 36I I c ITEHITEH    PCIBC096    IA-580-M/ULC  IVS4      .9            ~ sl  IP  zl as/
I    I    I C  ITEHITEH    PCIBC096    IA 580 H/ULC  IV 4    -1.0            ~ sl  IP  al asl I 471  33I  C  ITEHIIEH        IBC107  IA-580-M/ULC  I02C    32.9          1.ol 14ol 1I zil 96I 34I  C  ITEHITEH    PSIBC098    IA 580 M/ULC  IV 2      - 7            .5I    lr zl z6I I
I 81I 41I  C  ITEHITEH    PSIBC109    IA-580.H/ULc Ivs3      -.8            .6I    lr al asl I>>I    41I  C  ITEHITEH    PCIBC127    IA-560-SF/RM  IVS2      1.0                  IP al zil I    I    I C  ITEHITEH    PCIBC127    IA-560-SF/RH  IVS4    -1.0                    lr zl azl I >>I  41I  C  ITEHITEH    PCIBC098    IA-580.H/ULC  IVS2        .7          ~ 4I    lr zl 24I I    I    I C  ITEHITEH    PCIBC098    IA-580.M/ULC  IVS4    -.5            ~  4I  lr zl 24I I 43I 47I C    ITEHITEH    PSIBC101    IA-580-M/ULC  IVS3    -1.0          .6I    Ir zl zal                          I    I I 68I 50I c    ITEHITEH    PSIBC019    IA-580-H/ULC  IVS3    -1.1          .6I    IP zl as/                          I
                                                                                                                              'I I srl 51I C    ITEHITEH    PSIBC018    IA-580.H/ULC  IVS3      -.9          1.ol    IP al sal                          I    I 55I c  IIEHIIEH    SCIBC081    IA-seo-H/ULc Ioce        .0          .Bl    IP al z4I                          I    I I1sol 56I C    ITEHITEH    PslecO64    IA-580.M/ULC IDCT        .0                  IP al sel                          I    I Iiszl 58I C    ITEHITEH    PslecO64    IA-580 M/ULC IVS1      -.8          .7I    lr al 29I IA-SBO.H/ULC IVS3      - 7          .rl        zl 24I I 49I 59I C    ITEHITEH    PSIBC017                                                  IP 59I C  ITEHITEH    PGIBc077    IA-580.H/ULC  IDCT        .0        1.01    IP  zl sol I 59I  65I  c  ITEHITEH        IBC019  IA-580.H/ULC  I06H    18.3          .Bl 138I    1I 24I I137I 67I C    ITEHITEH    PCIBC075    IA-580-H/ULC  IDHT        .0          .7I    IP  al aol I 34l 68I C    ITEHITEH    PSIBC018    IA-580-M/ULC  IDCT        .0        1.ol    IP al 31I I    I  I  c ITEHITEH G NPLIBC018      IA-580-H/ULC  IDCB      .0                    Ir al 36I I 36I 68I  C  ITEHITEH    PSIBC018    IA-580-H/ULC  IVS3        .9                  IP  zl arl I 39I 69I  C  ITEHITEH    PSIBC019    IA-580-H/ULC I
IVS3      -.9          .5I    lr zl asl 70I  C  ITEHITEH    PSIBC082    IA 580.H/ULC  IVS3      -.8          1.1I    IP zl 31I
+-.-I"-I.--I-      I
                                      -I------------I-
 
0 INDICATIONS/TRENDING REPORT PSL-2 OUTAGE    : 10/95 COMPONENT      : STG IIB                                                                                              Page      2 DESCRIPTION      : 20K To 100/o                                                                                      Date : 11/16/95 Time : 08:40:06 I              (
Extent      I                      I                  10/95                  I    I (Row(LIn( Leg(Req(Tst/ Note(    Reel      Probe    (  Location      (Volts(Deg(ch      I X  (Diff( Location (Volts(Deg(ch          I X (
+      I    I  I    I
                              -I-        I            -I            ----I ---I        I--.I--    I
                                                                                                      --I-4s( ro(    C ITEHITEH  Is(ecosa      IA-580.H/ULC  IVS3    - 7            -4(      IP 2( 201
(                                                                      I                              I (35(  71(  C ITEHITEH  I C(BCO93    (A-580-H/ULC  (DCB                    .5(        2( 23(
I    I    I  C ITEHITEH  Pc(BC093      IA-580-H/ULC  IDCB    .0            .5(        2( 23(
I 451  711 C ITEHITEH    I c(ecO93    IA-580-H/ULC  IDCT      .0                        al as(
(97( r1(    C ITEHITEH  ps(ec074      IA-580-M/ULC  IVS4    -.9            .8(        2( 3o(
I 4s( ra(    C ITEHITEH  PLIBCOB      IA-580-H/ULC  IVS3    -.9            .5(        21 211 I 44( 76(    C ITEHITEH  PLIBC082      IA 580-H/ULC  IDHB      .0          1.2(          2( 32(
I 521 761 C ITEHITEH      PLIBC082      IA-580-M/ULC  IVS3      .6                    IP 2( as(                  I I  56( r6(    C ITEHITEH  PL(BC082      (A-580.H/ULC  IVS3    1.0                        2(  22(                I I  47( 77(    C ITEHITEH  PSIBC093      IA-580 H/ULc  IDHB      .0            .6(        2(  24(                I
(  55( 77(    C ITEHITEH  PSIBC093      IA-SBO.H/ULC IDCB      .0            .9(        2(  3o(                I I  44( rs(    C ITEHITEH  PSIBC082      (A-580-M/ULC IDHB    1.3            .9(        2(  as(                I C ITEHITEH  ps(ecosa      IA-580.H/ULC  IDCT  - 7              .8(        21 251 I    I    I                                                                                                      I I    I    I C ITEHITEH    PL(ecosa      IA-580-H/ULC  IDCB    .0            ~ rl        2(  24(                I 46(  rs(  C ITEHITEH GNPLIBC082      IA-580-M/ULC  IVS3    - 7          1.8(          2(  39(
I                                                                                                                  I        I            I I    I    I C ITEHITEH GNPLIBC082 PSIBC082 IA-580-H/ULC IA-580-H/ULC IVS3  1.0                          2(  35(                I        I,          I I    I    I C ITEHITEH                                IDCB                    ~ 5(        2(  21(                I          I          I I  48( 78(    C ITEHITEH  PSIBC082      IA-580-M/ULC  IDCB    1.0                        2(  34(
I  50( 78(    C ITEHITEH  PSIBC082      IA-580-M/ULC  IDHB      .7            .8(      IP 2(  26(
I    I    I C  ITEH(TEH GNPLIBC082      IA-580-M/ULC  IDCT  -.6            1.8(          2(  39(
(  52( 78(    C ITEH(TEH  Is(ecosa      IA-580-M/ULC  IVS3    -.6                      IP 2(  31(
I,88( I    I C  ITEHITEH 78( c ITEN(TEN Ps(scosa PLIBC054 IA-580-M/ULC IA-580-M/ULC IDCT IVS2
                                                              -.6
                                                                  .7
                                                                                .6(
                                                                                .8(
2(  23(
24(
I                                                                                      (I 2(
I  96( rs(    C ITEH(TEH  PSIBC087      (A-580.M/ULC  IVS2    -.8            .9(        2(  as(
I  51( 79(    C ITEHITEH  PSIBC093      IA-SBO.M/ULC (Dce      .0            .6(        2(  23(
(  57( 79(    C (TEHITEH GMPLIBC093      IA-580.H/ULC  IDCT      .0          1.9(          2(  45(
I  sa( so(    C ITEH(TEH  PLIBC082      IA-580 M/ULC  IDHB      ~ 8        1.5(          2(  36(
I    I    I C  ITEHITEH  PSIBC082      IA-580.H/ULC  (DCT  -.6              .6(        2(  as/
I  49( 81(    C ITEKITEH GHPL(BC093      IA-580-H/ULC  IDHT    -.2                        2(  33(
I    I    I  C ITEHITEH  PSIBC093      IA-580 H/ULc  Ioce    .0            .6(          2(  24(
I  98( 82(    C ITEHITEH  PCIBC076      IA-580.H/ULC  IVS3    1.0              4(        2(  23(                                -I--'/A I  49( 83(    C ITEHITEH  PBIBC093      IA-SBO.H/ULC IDHT      .0                        2(  34(
I    I    I C  ITEKITEH  PSIBC093    IA 8    H/ULC IDCT    .0            .8(          2(  29(
I  51( 83(    C ITEHITEH  PCIBC093    IA-580-4/ULc  IDGB      .0              41    IP 2(  ao(
I  691 831 C ITEHITEH      PLIBC067    IA-580.M/ULC ITSH        .6          1.411221 I  71( 83(    C ITEHITEH  PSIBC067    IA 80 M/ULC ITSH      1.3            ~  411411    1( 23(
(  73( 83(    C ITEHITEH  Ps(ecO67    (A-580-M/ULC ITSH        .7          .811371      1( as(
sr( 83(    C ITEHITEH  ps(eco67    IA-580 H/ULC IVS3      - 9            ~  41    IP 2( ao(
I I  891 831    C ITEHITEH  PSIBC067    IA-SBO.F/ULC Ivs3        .9          1.o(          21 321 I  48( 84(    C ITEHITEH  Pclecoeo    IA-580-M/ULC IDCT        .0          .91      IP 2( 32(
(  So( 84(    C ITEHITEH  PSIBC080    (A-580-M/ULC (DGT        .0          1.O(          2( 33(
(  88( 84(    C ITEHITEH  ps(ecO54    IA-580.H/ULC IVS2        .0          .8(          al  241      I I 511  851 C ITEHITEH GNPLIBC091      IA-580.H/ULC IDCB        .0          2.2(          1( 4s(
'.l---l -I-          I          I      -I -    ------I                            I I---I      I----I-I I
I  I
 
  +(
0
 
INDICATIONS/TRENDING REPORT
~
j COMPONENT    : STG ge OUTAGE PSL-2
: 10/95 page    3 DESCRIPTION : 20K To 100K                                                                                          Date : 11/16/95 Time : 08:40:06 I              I Extent      I                                          10/95                I    I          N/A (RoN]  tin]Leg]Req]Tst/ Note)    Reel      Probe      I  Lo cation      (Volts]Deg]Ch    ] X  ]Diff] Location ]Volts]oeg]ch  I X ]
    +    I    I  I  I
                                -I-        I            -I
    ] sr] ssl    C ITEHITEH  PSIBC091    IA-580-M/ULC IDCB          .0          .sl    ]I z] 24]
    ] 46] S6]    C ITEN(TEH  Pslecoso    IA 8    M/ULC IDCT        .0        1.O(      ]I 2] 33]
I    I    I C ITEHITEH  PS]BCOSO    IA-580 M/ULC IDCB        .0            .sl    Ip 2] zol I 54] s6]    C ITEHITEH  Pc]BCOSO    IA-580 M/ULC IDCT          .0          .S]    Ii z] Zl]
    ] ss] 86]    C ITEHITEH  PSIBC056    IA-580.M/ULC IVS3          .7          ~ 6]    ]I z] 24]
    ] 47] sr]    C ITEH]TEH  PCIBC091    IA 8    M/ULC IDHT        .0          ~ 9(    ]I 2]
I 55I 87I    C ITEHITEH  PCIBC091    IA-580 M/ULC  IDCT        .0                  I>>I 3Z]
    ] 73] sr]    C ITEHITEH  PSIBC067    IA-580 M/ULC  ITSH      1.4        1.4 I 137 I  11  28]
I 48I BSI    C ITEHITEH  PSIBCOSO    IA-580.M/ULC  IDHB        .0        l.o]      Ii z] 34]
I    I    I C ITEHITEH  PSIBCOSO    IA-580 M/ULC  IDCB      ~ 0            sl    I>>l    21 I
    ] sa] as/    C ITEHITEH  I s]ecOSO    ]A-580-M/ULC  ]VS3      -.8          ~ 9]    ]I 2]
    ] s6] ss]    C ]TEH]TEH GNPLIBcoso    IA-580-M/ULC  IVS3    -1.0          1.4(      I>>l
    ] 62] Ss]    C ]TEH(TEH  PCIBC080    IA-580-M/ULC  IVS3      -.9          .7(    ]I a] 2S]
I    I    I C ITEHITEH  PCIBCOBO    IA-580-M/ULC  IVS3    -.9            .r]    Ii zl zs]    I
    ] 72] as(    C ITEHITEH GNPL]BC056    IA-580 M/ULC  ITSH      1.2        2.9I141I 1I 22I          I I 51I 89I    C ITEHITEH  PCIBC091    ]A-580 M/ULC  ]OHB      . 3        .S]    ]I zl z3]      I I 44I 9o(    C ITEHITEH GNPL]BC080    IA-580 M/ULC  IDHB                  1.1]      I>>I    36(    I I 4S( 91]    C ITEHITEH GNPLIBC091    ]A-580-M/ULC  ]OHT        ~ 0                ]I al 39]    I I    I    I C ITEHITEH  PS]BC091    IA 580 M/ULC IV 3      -.9            .7]    Ip zl zsl    I I    I    I C ITEHITEH  PSIBC091    IA-SSO.M/ULC IVS3      -.5                    ]p 2] zz]      I I    I    I C ITEHITEH  PSIBC091    IA-580.M/ULC IDCT        ~ 0          .S]    lp zl 23(    I I    I    I C ITEHITEH  PSIBC091    IA-580.M/ULC  IDCT      .0            .S]    (I al 23]    I I    I    I C ITEHITEH  PSIBC091    IA-580-M/ULC  IDCB      ~ 0                  ]I 2] as/    I C ITEHITEH  PSIBC058    ]A-580-M/ULC  ]TSH        .9        2.0]130] 1] 32(        I
    ] 42]    92]  C ITEHITEH  Is(ecoso    IA-580-M/ULC  IDCT        .0                  ]p 2( z3]    I
    ] 46]    92]  C ITEHITEH GNPLIBCOSO    IA-580-M/ULC  IVS3      -.5                  Ii 2( 3zl    I s4]    92]  C ITEHITEH  ps]ecoso    ]A-580-M/ULC  Ivs3      - 7        1.O]      (I zl 34]
I                                                                                                    I I 6o]    92]  C ITEHITEH  PSIBCOSO    IA-580-M/ULC  IVS    .1 ~ 1          ~ S]    ]p z] zo]    I
    ] 43]    93]  C ITEHITEH  PCIBC091    IA-580-M/ULC  IDCB        .0            4(    ]I z] 22]    I
    ] 4zl 94]    C ITEHITEH  ps]ecoso    IA-580-M/ULC  IDCB        ~ 0        .9(    Ii 2] 31]    I I 461 94I    C ITEHITEH  PL]BC080    IA-580-M/ULC  IVS3    -1.0          .9]      Ii 2] 31(    I I    I    I C ]TEH]TEH  PSIBCOSO    IA-580.M/ULC  IDCB      .0          .7]      Ip 2] zr]    I
    ] 50]    94]  C ITEHITEH  PCIBC080    IA-SSO.M/ULC IVS3      .1 ~ 1        .6]      ]I z] 23]    I
( sa(    94]  C ITEHITEH  PSIBC080    IA S M/ULC IDCB            ~ 0        ~ 6]    ]I 2] 22(    =I I 94I    96I  C ITEHITEH  PSIBC078    IA-580.M/ULC IVS2        1 ~ 1 I
I 71]    97]  C ITEHITEH  PSIBC073    ]A-580-M/ULC ]VS4          .0        .7]      ]I 2] zs]    I
    ] 93]    97]  C (TEH(TEH  PSIBC078    IA-580-M/ULC,IVS2          .9        .S]      ]p zl 24]    I
    ] 34]    98(  C ITEHITEH  PSIBC097    IA-580 M/ULC IDHB          ~0        .S]                    I
    ] 3r] 99]    C ITEHITEH  PLIBC084    IA-580.M/ULC IVS3 -1.0                        ]I z] 32(    I I 94I100I    C ITEHITEH  Ps]Bc078    IA-580-M/ULC IVS2        -.8          .9]      ]I z] 33]    I I    I    I C ITEHITEH    PSIBC078    IA-SSO.M/ULC IVS2        .9                    ]I zl 33]    I I 93I101I    C ITEHITEH  PSIBC078    IA-580.M/ULC IVS2        ..8          .r]      ]p 2] 3ol    I C ITEHITEH  PCIBC078    IA-580.M/ULC IVS3      ..5            .5]      ]I zl 24]    I I---I---.              -I--------- --I-S
 
INDICATIONS/TRENDING REPORT PSL-2
: 10/95
                                                                            'Uj'AGE COMPONENT    : STG  &#xb9;B                                                                                                Page DESCRIPTION : 20K TO      100/                                                                                        Date : 11/16/95 Time : 08:40:06 I Extent                                                  10/95                    I    I          N/A IRoMILin(Leg(Req(Tst/Note( Reel            Probe        Location      lvoltsloeg(ch          I X  (Diff( Location (volts(Deglch  ( X I
'---  I--- I--- - I---'----I-I                        I            I                  I
                                                                          ----I- I---I---I----I-- ---------I-----I --I--I-- +
(13511011 C I TEH I TEH    Ps I Bc075  (A-580-M/ULC Ivs1        .o    I      1.11      IP 21 311      I I 1611061 c ITEHITEH      PSIBC052    (A-580-M/ULC lo3c                          .8(  IP 2( 29(
I 18(106( c ITEHITEH      PSIBC053    IA-580-M/ULC 103C      1.5                        IP 21 23(
I 3211061 c ITEHITEH      PSIBC052    IA-580-M/ULC I vs3
                                                                ..8                  .5(  IP 21 25(
I 50(1061 c ITEHITEH          IBC097    IA-580-M/ULC Ivs3      -.9                        IP 2( 22(
I 96(108( c ITEHITEH      Islgco4o    IA-580-M/ULC Ivs2      -.9                  .91  IP 2( 3o(
I 521110( C ITEHITEH      PLIBC086    (A-580-M/ULC Ivs3        .5            1.21      (r 2(35(
I 8911111  C  (TEHITEH    PSIBC099    IA-580-M/ULC lvs4        .7                      IP 2( 26(
I  96(1141  C  ITEHITEH    PS(BC042    IA-580 M/ULC Ivs2      -.8            1.21 I    I    I C ITEHITEH    Ps(Bc042    IA-580 M/ULC lvs2      .7                  .5(  lr 2( 22(
I    I    I C ITEHITEH    PSIBC042    IA-580.M/ULC lvs4    ..8                          lr 2( 21(
(129(115(    C  ITEHITEH      IBC043    IA-580-M/ULC IOBH        ~ 8          1.1(      II 2( as/
I 52(116(    C  ITEHITEH    PLIBC086    IA-580-M/ULC Ivs3      1.0                  .5(  Ii 2( 2ol I  8911171  C  ITEHITEH    Pslgco38    IA-580-M/ULC Ivs2      -.9                  .61  lr 2( 23(
I  5111211  C  ITEHITEH    SSIBC048    IA-580-M/ULC Ivs3      . 7                  ~ 61  II 2( 21(
I  9411241  C  ITEHITEH    PSIBC045    IA-580-M/ULC Ivs2      -.8                  .5(  II 2( 2ol I  5511251  C  ITEHITEH    PSIBC028    IA-580-M/ULC Ivs3      - 7            1.21      IP 2( 34(
I  6011341  C  ITEHITEH    PSIBC031    IA-580-M/ULC IVs3      -.9                  ~ 5(  (r 2( 22(
I  891135(  C  ITEHITEH    PLIBC032    IA-580.M/ULC IDCB        .0                ~ 21  (r 21 241 I  9411361  C  ITEN(TEN    PSIBC032    IA-580.M/ULC Ivs4        .0                .21  (r 2( 25(
I  7o(138(  C  ITEHITEH    PLIBC041    IA-580.M/ULC Ivs3        .6                .5(  lr 2( 21(
I  55(1391  C  ITEHITEH    PSIBC028    IA-580.M/ULc lvs3        .7          1.11        IP 2( 33(
I  92(142(  C  ITEHITEH    PSIBC034    IA 580-M/ULC Ivs2      1 ~ 0                .8(  lr 2( 221 I  9511431  C  ITEHITEH    PCIBC034    IA-580-M/ULC IVS2      1  0                ~ 8(  (r 2( 231 I 7611461    C  ITEHITEH    PCIBC034    IA-580-M/ULC IVS2      1.0                  .6(  (r 2( 2ol I  82(15ol  C  ITEHITEH    PSIBC035    IA-580-M/ULC Ivs3        .0                .61 I  641152(  C  ITEHITEH    PSIBC037    IA.580-M/ULC lvs2        .o                .8(  IP 2( 2ol
+-    I    I    I I--    - -I----- I I                                  I I    I  I Number  of  RECORDS Se  lected from Current Outage        156 Number  of  TUBES  Sole cted from Cu rrent Outage :    120
 
St. Lucie Unit 2
  ~
        ~  ~
L-96-72 Docket No. 50-389 Fall 1995 Refueling Outage NIS-1  ATTACHMENT 3 1995 OUTAGE SNUBBER FUNCTIONAL TESTING
 
==SUMMARY==
REPORT
 
L  i      ni    2 As part of Unit 2 Refueling Outage work scope, the following, tests and other related tasks were performed:
A. Visually  examined 106  of  230 mechanical    and  hydraulic snubbers.
B. Functionally tested    27 snubbers    which  failed during the previous outage.
Tag-2-019    Tag-2-093    Tag-2-146      Tag-2-178    Tag-2-243 Tag-2-039    Tag-2-094    Tag-2-156      Tag-2-183    Tag-2-315 Tag-2-041    Tag-2-096    Tag-2-157      Tag-2-185    Tag-2-316 Tag-2-066    Tag-2-102    Tag-2-169      Tag-2-241    Tag-2-322 Tag-2-067    Tag-2-120    Tag 177    Tag-2-242    Tag-2-334 Tag-2-070    Tag-2-144 C. Functionally tested 68 of 230 mechanical        and  hydraulic snubbers as part of the selected samples.
D. Completed  activities authorized    'by Plant Change/Modification packages:
M2    2 2M; Modified  1  snubber during this outage.
Tag-1-067,  (STAR-2-951523;CRN-279-292-5624)
Upgraded  with  a Lisega Hydraulic.
 
St. Lucie Unit 2 Snubber Test Results Iud t<ihria      Icashn      Bmulh      Guuura.'~
bor:  2-002      Initial Drag:    N/A SMPL-1      Activation:      0 Serial Number:  78331/11    Test Load:      240000        162647      %  Load: .68    198762  % Load: .83 Mark Number    SS-2-2A                      N/A Final Drag:
Capacity:      LSG-3102      Lock up:      6.60          5.02      Pass            5.02      Pass Rplcmnt S/N                  Release:        OA4          0.2        Pass            0.28      Pass Tag Number:      2-004      Initial Drag:    N/A Test Typo        SMPL-1    Activation:      0 Serial Number:  78331/12    Test Load:      240000        156542      % Load:.65      198868    % Load:.83 Mark Number      SSR-2A      Final Drag:      N/A Capacity:        LSG-3102      Lock up:      6.60          5.31      Pass            5.16    Pass Rplcmnt S/N                  Release:        0.44          0.16      Pass            0.04      Pass Tag Number:    2-017        Initial Drag:    800          703.1      Pass            859.5    Fail Test Type      SMPL-1      Activation:      0 Serial Number:  33336-1      Test Load:      32000          37212      % Load: 1.16    37477    % Load: 1.17 Mark Number    2A1        Final Drag:      800          579.4      Pass            728.1    Pass Capacity:      PMHQO          Lock up:      N/A Rplcmnt SIN                  Release:      25.00          11.35    Pass            11.21    Pass T      mber:  2-019        Initial Drag:    800          552.1      Pass            358.2    Pass pe    PEV.FAIL    Activation:      0 Ser    Number: 33486-1      Test Load:      32000        37056      %  Load: 1.16    39471    % Load: 1.23 Mark Number    281        Final Drag:      800          420.8      Pass            247.8    Pass Capacity:      PMHAO        Lock up:        N/A Rplcmnt S/N                  Release:        25.00        11.35      Pass            12.25    Pass Tag Number:    2-023      Initial Drag:    21            6.3        Pass            7.6      Pass Test Type      SMPL-1      Activation:      0 Serial Number:  61211/61    Test Load:      540            550.3      %  Load: 1.02  560      % Load: 1.04 Mark Number    RC-44-R7                    21            7.6        P.ass            9.3      Pass Final Drag:
Capacity:      LSG-3018      Lock up:        14.17        10.20      Pass            8.35    Pass Rplcmnt S/N                  Release:        4.72          2.58      Pass            1.53      Pass Tag Number:    2-024      Initial Drag:    21            8.9        Pass            12.7      Pass Test Type      SMPL-1      Activation:      0 Serial Number:  61211/66    Test Load:      540            555.2      % Load: 1.03    564.4    % Load: 1.05 Mark Number    RC-44-R7                    21            9.4        Pass            12.4      Pass Final Drag:
Capacity:      LSG-3018      Lock up:      14.17          10.05      Pass            8.42      Pass Rplcmnt S/N                  Release:      4.72          2.41        Pass            2.51      Pass Tag Number:    2-037      Initial Drag:    7500          78.5        Pass            56.9      Pass Test Type      SMPL-1      Activation:      .02          .013        Pass            .008      Pass S        umber: 12504      Test Load:      12000          12389.3      Load: 1.03    11279.2  % Load: .94 mber  SIR205-4080 Final Drag:      7500          31          Pass            24.7      Pass Capacity:      PSA-10        Lock up:      N/A Rplcmnt S/N                  Release:      N/A
 
St. Lucie Unit 2 Snubber Test Results IcsiSrihxia      Xemxl      Ecaulfs    Camarade~    Brudh 2-038      Initial Drag:    75            22.3 ber:
T      pe    SMPL-2      Activation:      .02            .019      Pass            .008    Pass Serial Number: 19221      Test Load:      1200            1281.1    % Load: 1.07    1281.9  % Load: 1.07 Mark Number    CH-103-R10A Final Drag:      75            18.8      Pass            26.3    Pass Capacity:      PSA-1        Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-039      Initial Drag:    17.5          13.8      Pass            23.3    Fail Tag Number:
Test Type      PEV.FAIL    Activation:      .02          .01        Pass            .015    Pass Serial Number: 38503      Test Load:      280            274.9      % Load: .98    254.5    % Load: .91 Mark Number-  SI-83-R3    Final Drag:      17.5          16.4      Pass            17.5    Pass Capacity:      PSA-1/4      Lock up:      N/A Rplcmnt S/N    38503        Release:        N/A 2-040      Initial Drag:    17.5          3.9        Pass            3.4      Pass Tag Number:
Test Type      SMPL-1      Activation:      .02          .01        Pass            .01    Pass Serial Number: 29179      Test Load:      280            267.5    % Load: .96      300.1    % Load: 1.07 Mark Number    MSI-9-R88  Final Drag:      17.5          4.5        Pass            3.7    Pass Capacity:      PSA-1/4      Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-041      Initial Drag:    17.5          10.4      Pass            12.2    Pass T      mber:
pe    PEV.FAIL    Activation:      0 Senal Number:  61211/73    Test Load:      540            571.2    % Load: 1.06    553.7  % Load: 1.03 Mark Number    8-23-R1A    Final Drag:      17.5          5.9        Pass            8.3      Pass Capacity:      LSG-3018      Lock up:      14.72          11.28    Pass            9.50    Pass Rplcmnt S/N                  Release:      4.72          2.75      Pass            2.26    Pass 2-045      Initial Drag:    21            10.8      Pass            16.3    Pass Tag Number:
Test Type      SMPL-1      Activation:      0 Serial Number: 61211/55    Test Load:      540            563.      % Load: 1.04    533.1  % Load: .99 Mark Number    CH-108-R4  Final Drag:      21            6.9        Pass            10.1    Pass Capacity:      LSG-3018      Lock up:      14.72          10.05    Pass            8.93    Pass Rplcmnt S/N                  Release:      4.72          2.59      Pass            1.99    Pass 2-046      Initial Drag:    17.5        5          Pass            5      Pass Tag Number:
Test Type                  Activation:      .02          .011      Pass            .012    Pass Serial Number: 11832      Test Load:      280          281.5      % Load: 1.01    297.3  % Load: 1.06 Mark Number    CH-108-R8  Final Drag:      17.5                    Pass            1.7      Pass Capacity:      PSA-1/4      Lock up:      N/A Rplcmnt S/N    38510        Release:      N/A 2-049      Initial Drag:    17.5        4.8        Pass            4.6      Pass Tag Number:
Test Type      SMPL-1      Activation:      .02          .009      Pass            .009    Pass umber: 37657      Test Load:      280          300        % Load: 1.07    287.7    % Load: 1.03 umber  8-15-R10    Final Drag:      17.5        6.5        Pass            6        Pass Capacity:      PSA-1/4      Lock up:      N/A Rplcmnt S/N                  Release:      N/A
 
St. Lucie Unit 2 Snubber Test Results Xm~ltgria      Icnsha      Em'umaramaa              Eesuih 2-050          Initial Drag:                  71.9      Pass          82.3      Pass ber:
Te    ype      SMPL-3        Activation:      .02          .015      Pass        .011      Pass Serial Number:  16436          Test Load:      12000          12817    % Load: 1.07  12149    % Load: 1.01 Mark Number    SI 4201-7741 8 Final Drag:      2500          76.9      Pass        62.6      Pass Capacity:      PSA-10          Lock up:      N/A Rplcmnt S/N                      Release:        NIA 2-053          Initial Drag:    300            18.8      Pass          16.6      Pass Tag Number:
Test Type      SMPL-4        Activation:      .02          .014      Pass        .009      Pass Serial Number:  16749          Test Load:      4800          5267.1    % Load: 1.1  4201.9    % Load:.88 Mark Number    SIP200-63438  Final Drag:      300          19.1      Pass        16        Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-054          Initial Drag:    300            16.2      Pass          20.2      Pass Tag Number:
Test Type      SMPLA          Activation:      .02          .013      Pass        .006      Pass Serial Number:  16760          Test Load:      4800          5040.7    % Load: 1.05  4210.3    % Load: .88 Mark Number    SI4200-63438  Final Drag:      300          21.8      Pass        14.1      Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-055          Initial Drag:    300          20.8      Pass          30.1      Pass mber:
SMPL-4        Activation:      .02          .015      Pass        .013      Pass Serial Number  17709          Test Load:      4800          5252      % Load: 1.09  5070.6    % Load: 1.06 Mark Number    SIR200-63408  Final Drag:      300          17.2      Pass        29.9      Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-056          Initial Drag:    300          28.5      Pass          31.6      Pass Tag Number:
Test Type      SMPLA          Activation:      .02          .012      Pass        .009      Pass Serial Number:  16765          Test Load:      4800          5232.3    % Load: 1.09 4613.8    % Load: .96 Mark Number    SI4200-63408  Final Drag:      300          24.4      Pass        25.6      Pass Capacity:      PSA-3            Lock up:      NIA Rplcmnt S/N                      Release:        N/A 2-057          Initial Drag:    300          18.3      Pass          14.2      Pass Tag Number:
Test Type      SMPLR          Activation:      .02          .009      Pass        .007      Pass 16753                          4800          5104.5    % Load: 1.06 21.75162.7 % Load: 0 Serial Number:                Test Load:
Mark Number    SIC200-3268    Final Drag:      300          13.8      Pass        21.7      Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                    Release:        NIA 2-058          Initial Drag:    300          34.8      Pass          14.2      Pass Tag Number:
Test Type      SMPL-4        Activation:      .02          .012      Pass        .007      Pass umber: 21266          Test Load:      4800          4760.6    % Load:.99  4791.5    % Load: 1 umber  Sl-4200-322C  Final Drag:      300          26.3'ass                23.4      Pass Capacity:      PSA-3            Lock up:      NIA Rplcmnt S/N                    Release:        N/A
 
St. Lucie Unit 2 Snubber Test Results j.CRf CCl~lR    XCQREl      ECS~        QglIgZRSK?Q    hIQR 2 066          Initial Drag:                  145.6      Pass              1118    Fail mber:
ype    PREY FAIL      Activation:      .02          .022      Fail              .017  ~  Pass Serial Number: 16610          Test Load:      12000          12887.1    % Load: 1.07      12112.2  % Load: 1.01 Mark Number    SI-4203-71    Final Drag:      750          209.9      Pass            615.7    Pass Capacity:      PSA-10          Lock up:      N/A Rplcmnt S/N    16610            Release:        N/A 2-067          Initial Drag:    750          3.1        Pass            124.7    Pass Tag Number:
Test Type      PREV FAIL      Activation:      0            0          Pass            0        Pass Serial Number: 61256/32      Test Load:      12000          15000    % Load: 1.25      15000    % Load: 1.25 Mark Number    SI4201-7760    Final Drag:      750          1000      Fail            1000      Fail Capacity:      LSG-3062RF      Lock up:      14.72          13.79    Pass            g.g2      Pass Rplcmnt S/N    61256/32        Release:        4.72          2.70      Pass            2.55      Pass 2-069          Initial Drag:    17.5          6.3      Pass              6.4      Pass Tag Number:
Test Type      SMPL-1        Activation:      .02          .006      Pass            .005      Pass Serial Number: 38528          Test Load:      280            313.9    % Load: 1.12      6.5308.4 % Load: .02 Mark Number    SIR208-264B    Final Drag:      17.5          6.9        Pass            6.5      Pass Capacity:      PSA-1/4          Lock up:      N/A Rptcmnt S/N                    Release:        N/A 2-070          Initial Drag:    300          183.8    Pass              131.1    Pass umber:
pe    PREV FAIL      Activation:      0 Serial Number: PD  87485-1416 Test Load:      11200          12985.6  % Load: 1.16      12662.1  % Load: 1.13 Mark Number    SIP200-6348    Final Drag:      300          175.9      Pass            141.4    Pass Capacity:      PMH-2200        Lock up:      30.00        29.18      Pass            26.19      Pass Rplcmnt S/N                    Release:        30.00        25.33      Pass            24.45      Pass 2-072          Initial Drag:    75            10.5      Pass            5        Pass Tag Number:
Test Type      SMPL-3        Activation:      .02          .008      Pass            .009      Pass Serial Number: 14878          Test Load:      1200          1266      %  Load:1.06      1307.2  % Load:1.09 Mark Number    Sl-4205-6428B  Final Drag:      75            8.3        Pass            7.2        Pass Capacity:      PSA-1            Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-074          Initial Drag:    300          15        Pass            15.4      Pass Tag Number:
Test Type      SMPL-4        Activation:      .02          .010      Pass            .008      Pass Serial Number: 16752          Test Load:      4800          4686.3    % Load: .98      4316.2    % Load: .9 Mark Number    SIP205-6713B  Final Drag:      300          20.9      Pass            11.1      Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-075          Initial Drag:    300          30.4      Pass            16.1      Pass Tag Number:
Test Type      SMPL-4        Activation:      .02          .01        Pass            .007      Pass Number: 16769          Test Load:      4800          4743.5    %  Load: .99    4528      % Load: .94 umber  SIP205-6713B  Final Drag:      300          23.8      Pass            23.5      Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                    Release:        N/A
 
St. Lucle Unit 2 Snubber Test Results 2-079        Initial Drag:    75                                    15.2  Pass mber:
T              SMPL-3        Activation:      .02          .008      Pass        .008    Pass ypo 24734                          1200          1274.9    % Load: 1.06  1275.9 % Load: 1.06 Serial Number:                Tost Load:
Mark Number    SI-4205-739B  Final Drag:      75            7.4        Pass        7.1    Pass Capacity:      PSA-1          Lock up:      NIA Rplcmnt SIN                    Release:        NIA 2-080        Initial Drag:    75          7.6        Pass          10.6  Pass Tag Number:
Test Type      SMPL-3        Activation:      .02          .006      Pass        .008    Pass 20363                          1200          1238.4    % Load: 1.03  1307.9 % Load: 1.09 Ser/al Number:                Tost Load:
Mark Number    SIP205-6428B  Final Drag:      75            11.2      Pass        7.2    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-084        Initial Drag:    300          26.5      Pass        31.7    Pass Tag Number:
Test Type      SMPL-3        Activation:      .02          .008      Pass        .005    Pass 29504                          4800          5369.3    % Load: 1.12 4502.8  % Load: .94 Serial Number:                Test Load:
Mark Number    SI-4204-1100B Final Drag:      300          43.1      Pass        30.8    Pass Capacity:      PSA-3          Lock up:      NIA Rplcmnt S/N      24745          Release:        NIA 2-088        Initial Drag:    75            26.9      Pass        30.5    Pass mber:
SMPL-1        Activation:      .02          .02        Pass        .017    Pass pe 7419                            1200          1319.8    % Load: 1.1  1313.0 % Load: 1.09 Senal Number:                Test Load:
Mark Number    SI4204-1270B                  75            11.1      Pass        13.6    Pass Final Drag:
Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N    12289          Release:        N/A 2-089        Initial Drag:    75            12.6      Pass          19.7  Pass Tag Number:
Test Type      SMPLR        Activation:      .02          .008      Pass        .006    Pass 7313          Test Load:        1200          1203.4    % Load: 1    1349 2 % Load'  12 Serial Number:
Mark Number    SI 4204-1270B Final Drag:      75            13.6      Pass        17.4    Pass Capacity:        PSA-3          Lock up:      NIA Rpicmnt SIN                    Release:        N/A 2-093          Initial Drag:    2500          312.6    Pass          155.5  Pass Tag Number:
PEV.FAIL    Activation:      .02          .016      Pass        .017    Pass Test Type 11971                        40000          36950    % Load: .92  43720  % Load: 1.09 Serial Number:                Test Load:
Mark Number      BF-4007-7017                  2500        226.9      Pass        267.8  Pass Final Drag:
Capacity:        PSA-35          Lock up:      NIA Rplcmnt S/N                    Release:        NIA 2-094        Initial Drag:    2500        545.4    Pass        219.7  Pass Tag Number:
Test Type        PEV.FAIL    Activation:      .02          .018      Pass        .018    Pass 8291                          40000        235      % Load:.01  225.1  % Load:.01 Number:                Tost Load:
umber    MS-4100-16A                    2500          76.5      Pass        104.7  Pass Final Drag:
Capacity:      PSA-35          Lock up:      N/A Rplcmnt S/N                    Release:        N/A
 
St. Lucie Unit 2 Snubber Test Results Xe~ltexia      Icosi'emi@              Gamareasho  Eesvlh 2-096        Initial Drag:    6000          1261.4    Pass            1410.6  Pass mber:
PEV.FAIL      Activation:      .02          .02        Pass          .017    Pass pe Serial Number:  2472          Test Load:      96000        95240      % Load: .99    197230  % Load 2 05 MS-4100-16B                    6000          1079.3    Pass          1167.9  Pass Mark Number                  Final Drag:
Capacity:      PSA-100        Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-099        Initial Drag:    75          8.1        Pass          6.511.5  Pass Tag Number:
Test Type      SMPL-1        Activation:      .02          .015      Pass          .018    Pass Serial Number:  26006        Test Load:      1200          1296.3    % Load: 1.08    1256.7  % Load: 1.05 Mark Number    SIQ203-69B                    75            4.2        Pass          7.4      Pass Final Drag:
Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N    26006          Release:        N/A 2-100        Initial Drag:    75            2.8      Pass            5.1    Pass Tag Number:
SMPL-3        Activation:      .02          .010      Pass          .010    Pass Test Type 20360                          1200          1284.3    % Load: 1.07    1272.1  % Load: 1.06 Serial Number:                Test Load:
SI4203-69B                    75            3.1        Pass          5        Pass Mark Number                  Final Drag:
Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N      6955          Release:        N/A 2-102        Initial Drag:    75            16.6      Pass            18.6    Pass T      umber:
PREV FAIL    Activation:      .02          .016      Pass          .011    Pass pe 26062        Test Load:        1200          1344.6    % Load: 1.12    1349.1  % Load: 1.12 Se al Number:
SIP203-24C                    75            18.5      Pass          15.1    Pass Mark Number                  Final Drag:
Capacity:      PSA-1          Lock up:        N/A Rplcmnt S/N                    Release:        N/A 2-103          Initial Drag:    75            27.6      Pass            14.8    Pass Tag Number:
SMPL-3        Activation:      .02          .009      Pass          .010    Pass Test Type 14872                          1200          1342.4  % Load:1.12    1339.1  % Load:1.12 Serial Number:                Test Load:
Mark Number      SIR203-24B                    75            12.1      Pass          6.7      Pass Final Drag:
Capacity:        PSA-1          Lock up:      N/A Rplcmnt S/N    14872          Release:        N/A 2-104          Initial Drag:    75            15.2    Pass            11.2    Pass Tag Number:
SMPL-3      Activation:      .02          .011      Pass          .012    Pass Test Type 26010                          1200          1310.5  % Load: 1.09    1292,3  % Load: 1.08 Serial Number:                Test Load:
SIP203-24B                    75            8.3      Pass          13.0    Pass Mark Number                  Final Drag:
Capacity:        PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-106        Initial Drag:    300          46.8      Pass            42.9    Pass Tag Number:
SMPL-1      Activation:      .02          .011      Pass          .007    Pass Test Type Number:  21267        Test Load:      4800          4901.3    % Load: 1.02 '273.1    % Load: .89 umber    SIQ203-581 B                  300          31.5      Pass          27.7    Pass Final Drag:
Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:        N/A
 
St. Lucie Unit 2 Snubber Test Results 2-107        Initial Drag:                21.2      Pass          22.2  Pass bor:
Te      ype      SMPLA        Activation:    .02 18680        Test Load:      4800          5119.6    % Load: 1.07 4884.6  % Load: 1.02 Serial Number:
Mark Number      SI4203-581B  Final Drag:    300          26.5      Pass        30 8    Pass Capacity:        PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-108        Initial Drag:  ?5            8.7        Pass          17    Pass Tag Number:
Tost Type        SMPL-1      Activation:    .02          .013      Pass        .013    Pass 14884        Test Load:      1200          1197.3    % Load: 1    1176.3 % Load:.98 Serial Number:
Mark Number      SI-4200-314B Final Drag:    75            12.7      Pass        13.7    Pass Capacity:        PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-109        Initial Drag:    75          7.3        Pass        6.2    Pass Tag Number:
Test Type        SMPLX        Activation:    .02          .008      Pass        .007    Pass 19231        Test Load:      1200          1233.7    % Load: 1.03  1263.7 % Load: 1.05 Serial Number:
Mark Number    S IP200-314B Final Drag:    75            8.3        Pass        5.7    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-110        Initial Drag:    750          60.7      Pass        47.7    Pass T        mba r.
SMPL-1      Activation:    .02          .018      Pass        .01    Pass pe Serial Number  11393        Test Load:      12000          12328.3  % Load: 1.03  116485 % Load 97 Mark Number    8FP006-7407  Final Drag:    750          48.3      Pass        60      Pass Capacity:      PSA-10        -Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-120        Initial Drag:    2500        294        Pass        313.7  Pass Tag Number:
Test Type      PEV.FAIL    Activation:    .02          .018      Pass        .016    Pass 9282        Test Load:      40000        4p64p      % Load; 1.p2 39670  % Load:.99 Serial Number:
Mark Number    BF-4007-7008 Final Drag:    2500          109.5      Pass        80.1    Pass Capacity:      PSA-35        Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-124        Initial Drag:    17.5          5.6      Pass        6.4    Pass Tag Number:
Test Typo      SMPL-1      Activation:    .02          .009      Pass        .008    Pass
                                                                                                % Load: 1.08
                                                        '80 Serial Number:  29366        Test Load:                    296.1    % Load: 1.06 301 Mark Number    RS-98-R12    Final Drag:      17.5        5.1        Pass        6      Pass Capacity:      PSA-1/4        Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-125        Initial Drag:    17.5        4.5      Pass        4.5    Pass
'ii, Tag Number:
SMPL-0      Activation:      .02          .008      Pass        .007    Pass
  )jTest Type 37659        Test Load:      280            291.9    % Load: 1.04 298.2  % Load: 1.07 umber:
umber    RC-98-R4B  Final Drag:      17.5        3.5        Pass        4.6    Pass Capacity:        PSA-1/4      Lock up:      N/A Rplcmnt S/N    38489        Release:        N/A
 
St. Lucie Unit 2 Snubber Test Results XeaGritaria      IcllKE        Emily        GamKaz~        Emdh 2-140        Initial Drag:    17.5          2.0          Pass            2.2      Pass mber:
SMPL-1        Activation:      .02          .011        Pass              .011      Pass Serial Number'2612            Test Load:      280            252.        '/0 Load: .9      294.9    '/0 Load: 1.05 Mark Number    RC-99-R5      Final Drag:      17.5        1.9        Pass              2.8      Pass Capacity:      PSA-1/4        Lock up:      NIA Rplcmnt S/N                    Release:        N/A 2-144        Initial Drag:    75            22.        Pass              48.5      Pass Tag Number:
Test Type      PREV FAIL    Activation:      .02          .01        Pass              .01      Pass Serial Number:  14876        Test Load:        1200          1294.3      '/o Load: 1.08    1233.4    0/0 Load: 1.03 Mark Number    RC4300-15    Final Drag:      75            35.2        Pass              42.0      Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:        NIA 2-146        Initial Drag:    750          78          Pass            64.8      Pass Tag Number:
Test Type      PEV.FAIL      Activation:      .02          .019        Pass              .012      Pass Serial Number:  16442        Test Load:        12000        12418.8    '/o Load: 1.03    113p3.3    /o Load: .94 Mark Number    RCP300-123    Final Drag:                    25          Pass              47 6      Pass 750'/A Capacity:      PSA-10          Lock up:
Rplcmnt S/N                    Release:        NIA 2-150        Initial Drag:    75            13          Pass            11.5      Pass T      umber pe      SMPL-1      Activation:      .02          .016      Pass                024    Fail S      Number:  14880        Test Load:      1200          1227.6    o/0  Load: 1.02  1203.8    '/o Load:  1 Mark Number    RCQ300-125    Final Drag:      75            12.4      Pass              16.1    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N    26002          Release:        N/A 2-152        Initial Drag:    75            10        Pass              9.8      Pass Tag Number:
Test Type      SMPL-2        Activation:      .02          .017      Pass              .016      Pass Serial Number:  16141        Test Load:      1200          1212.7    '/o  Load: 1.01  1285.5    /0 Load: 1.07 Mark Number    RC-4300-28    Final Drag:      75          5.1        Pass              4.6      Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-153        Initial Drag:    300          38.8        Pass              37.3    Pass Tag Number:
Test Type      SMPL-1        Activation:      .02          .017        Pass              .01      Pass 16568                        4800          4916.3    '/0  Load: 1.02  4453.9    '/0 Load: .93 Serial Number:                Test Load:
Mark Number    RC-4300-26B  Final Drag:    300          39.4        Pass              46.0      Pass Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-155        Initial Drag:    750          20.6      Pass              16.9    Pass Tag Number:
Test Type      SMPL-1        Activation:      .02          .019        Pass              .017      Pass umber: 10177      . Test Load:      12000        12751.6    '/o  Load: 1.06  1p576.2  /0 Load: .88 umber  RCQ300-126    Final Drag:    750          72.1        Pass              42        Pass Capacity:      PSA-10          Lock up:      N/A Rplcmnt S/N                    Release:      N/A
 
St. Lucie Unit 2 Snubber Test Results IQSfSZliQdR    T  i~      ggggjg      ~~~        QgggJQ 2-156          Initial Drag:                  10.8      Pass          13.5    Pass ber:
Te              PREV FAIL      Activation:      .02          .007      Pass          .010    Pass ype Serial Number:  12790          Test Load:      1200          1348,4    % Load: 1,12  1250.2  % Load: 1.04 Mark Number    RCR300-64B    Final Drag:      75            14.6      Pass          10.5    Pass Capacity:      PSA-1            Lock up:      N/A Rpicmnt S/N    26008            Release:        N/A 2-157          Initial Drag:    75            19.6      Pass          25.2    Pass Tag Number:
Test Type      PREV FAIL      Activation:      .02          .016      Pass          .017    Pass 15148          Test Load:      1200          1301.6    % Load: 1.08  1255.9  % Load: 1.05 Serial Number:
Mark Number    RC4300-7066                    75            5.3        Pass          15.9    Pass Final Drag:
Capacity:      PSA-1            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-160          Initial Drag:    300          12        Pass          12.8    Pass Tag Number:
Test Type      SMPL-2        Activation:      .02          ,013      Pass          .008    Pass 20253          Test Load:      4800          5155      % Load: 1.07  4338    % Load:.9 Serial Number:
Mark Number    RC<300-12      Final Drag:      300          13.1      Pass          13.1    Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-161          Initial Drag:    300          17.9      Pass          8.7      Pass mber:
pe      SMPL-2        Activation:      .02          .013      Pass      '008        Pass 20262          Test Load:      4800          5051      % Load: 1.05  4382    % Load: .91 Serial Number Mark Number    RCC300-12      Final Drag:      300          11.4      Pass          15.6    Pass Capacity:      PSA-3            Lock up:      N/A Rplcmnt SIN                    Release:        N/A 2-162          Initial Drag:    750          53.5      Pass          42.5    Pass Tag Number:
SMPL-2        Activation:      .02          .019      Pass          .011    Pass Test Type 11387          Test Load:        12000        12280.8  %Load:1.02    11225.9 %Load:.94 Serial Number:
Mark Number    RCP300-157    Final Drag:      750          51.7      Pass          36.5    Pass Capacity:      PSA-10          Lock up:        N/A Rplcmnt S/N                    Release:        N/A 2-165          Initial Drag:    750          70        Pass          59.4    Pass Tag Number:
Test Type      SMPL-2        Activation:      .02          .02      Pass          .017    Pass 16439                          12000          11494.2  % Load: .96    10744.9 % Load: .9 Serial Number:                Test Load:
Mark Number    RC<300-157    Final Drag:      750          72.6      Pass          72.5    Pass Capacity:        PSA-10          Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-167          Initial Drag    300            184.1    Pass          224.6  Pass Tag Number:
Test Type      SMPL-1        Activation:      0 P D87773-1891                  11200          13596.4  % Load: 1.21  13142  % Load: 1.17 Number:                Test Load:
RC-4300-147                    300          163.3    Pass          205.1    Pass umber                  Final Drag:
Capacity:      PMH-2200        Lock up:      30.00        26.85    Pass          24.53    Pass Rplcmnt S/N                      Release:        30.00        22.93    Pass          22.28    Pass
 
St. Lucie Unit 2 Snubber Test Results 3y~Cihria      jenaiua    higa        Qgmgrmgiga  fhgglh 2-169          Initial Drag:    300          36.1      Pass          28.5    Pass ber:
PREV FAIL    Activation:      .02          .012      Pass          .008    Pass Te    ype 101                            4800          4887      % Load: 1.02  4262.6  % Load:.89 Serial Number:                Test Load:
RCP300-139                      300          15.5      Pass          10.4    Pass Mark Number                    Final Drag:
Capacity:      PSA-3            Lock up:      N/A Rplcmnt SIN                      Release:        N/A 2-170          Initial Drag:    300          33.9      Pass          25.5    Pass Tag Number:
SMPL-2      Activation:      .02          .013      Pass          .008    Pass Test Type 20264                          4800          5229.1    % Load: 1.09  4497.5  % Load: .94 Serial Number:                Test Load:
RC-4300-138                    300          11.3      Pass          14      Pass Mark Number                    Final Drag:
Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-172          Initial Drag:    750          49.7      Pass            67.1    Pass Tag Number:
SMPL-2      Activation:      .02          .02        Pass          .014    Pass Test Type 8934                            12000        11174.6  %  Load:.93    11373.1 % Load:.95 Serial Number:                Test Load:
Mark Number    RCQ300-6134C                    750          23.2      Pass          34 6    Pass Final Drag:
Capacity:      PSA-10          Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-173          Initial Drag:    750          52.5      Pass          42.2    Pass mber:
SMPL-1        Activation:      .02          .017      Pass          .012    Pass 11340                            12000        11274.7  % Load:.94      11141.0 % Load:.93 Serial Number                  Test Load:
Mark Number    RC-4300-61 34C Final Drag:      750          37.5      Pass          37 7    Pass Capacity:      PSA-10          Lock up:        N/A Rplcmnt S/N                    Release:        N/A 2-176          Initial Drag:      300          74.5      Pass            80.8    Pass Tag Number:
Test Type        SMPL-2        Activation:      .02          .012      Pass          .011    Pass
                '?                              4800          5193.5    % Load: 1.08    4640.3  % Load: .97 Serial Number:                Test Load:
RC-4300-6134A                  300          17.2      Pass          18.9    Pass Mark Number                  Final Drag:
Capacity:      PSA-3            Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-177          Initial Drag      17.5        6.3      Pass            7.2    Pass Tag Number:
Test Type        PREV FAIL    Activation:      .02          .01      Pass          .009    Pass 29182                          280          273.7    % Load: .98    305.1  % Load: 1.09 Serial Number:                Test Load:
Mark Number      RC-97-R18    Final Drag:      17.5          8.1      Pass          5.3      Pass Capacity:        PSA-1/4        Lock up:      N/A Rplcmnt S/N                      Release:        N/A 2-178          Initial Drag:    17.5          5.3      Pass          6.3      Pass Tag Number:
PREV FAIL    Activation:      .02          .013      Pass          .013    Pass Test Type 29198                          280            294.8    % Load: 1.05    276.5  % Load:.99 umber:                Test Load:
umber    RC-97-R18                      17.5          8.2      Pass          4.4      Pass Final Drag:
Capacity:        PSA-1/4        Lock up:      N/A Rplcmnt S/N                      Release:        N/A
 
St. Lucie Unit 2 Snubber Test Results Im~C'aia        Xeamul      Emitted    Gmareaahn  Emit 2-183        Initial Drag:    75                                      7.5    Pass mber:
T              PEV.FAIL    Activation:    .02          .01        Pass          .017    Pass ype Serial Number:  16663        Test Load:      1200          7.5        % Load: .01    10.3  % Load: .01 Mark Number    RC-4300-1067 Final Drag:    75            7.5        Pass            10.3  Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-184        Initial Drag:    75          9.6        Pass            4.3    Pass Tag Number:
Test Type      SMPL-2      Activation:    .02          .016      Pass          .018    Pass Serial Number:  19228        Test Load:      1200          1300      % Load: 1.08    1319  % Load: 1.1 Mark Number    RC-4300-1067 Final Drag:    75            10        Pass          5.3    Pass Capacity:      PSA-1          Lock up:      N/A Rpicmnt S/N                    Release:      N/A 2-185        Initial Drag:    300          37.6      Pass            45.1  Pass Tag Number:
Test Type      PREY FAIL    Activation:    .02          .013      Pass          .008    Pass Serial Number:  30534        Test Load:      4800          5295.8    % Load: 1.1    4643.5 % Load: .97 Mark Number    RC4300-52    Final Drag:    300          40.        Pass          41.4    Pass Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:      NIA 2-186        Initial Drag:    300          31.7      Pass            31.2  Pass umber:
pe    SMPL-1      Activation:    ,02          .014      Pass          .01    Pass Senal Number:  16575        Test Load:      4800          4668.4    % Load: .97    4660.9 % Load: .97 Mark Number    RC-4300-53B  Final Drag:    300          30.1      Pass          30.1    Pass Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:      N/A 2-196        Initial Drag:    2500        218.5      Pass            208.6  Pass Tag Number:
Test Type      SMPL-1      Activation:    .02          .015      Pass          .018    Pass Serial Number:  9281        Test Load:      40000        35170      % Load: .88    42270  % Load: 1.06 Mark Number    MS-4101-314  Final Drag:    2500          42.5      Pass          79.4    Pass Capacity:      PSA-35        Lock up:      N/A Rplcmnt S/N                    Release:      NIA 2-200        Initial Drag:    75          10.3      Pass          7.9    Pass Tag Number:
Test Type      SMPL-3      Activation:    .02          .008    . Pass          .008    Pass 21579        Test Load:      1200          1305.1    % Load: 1.09    1322.1 % Load: 1.1 Serial Number:
Mark Number    SI-80-R5    Final Drag:    75            4.2        Pass          14.5    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                  Release:      N/A 2-206        Initial Drag:    17.5        6.6        Pass          8.6    Pass Tag Number:
Test Type      SMPL-1      Activation:    .02          .011      Pass          .012    Pass 19077      Test Load:      280          303.3      % Load: 1.08  296.3  % Load: 1.06 Number:
umber  MSIQ-R6      Final Drag:    17.5          4.0        Pass          4.8      Pass Capacity:      PSA-1/4        Lock up:      NIA Rplcmnt S/N                  Release:      N/A
 
St. Lucie Unit 2 Snubber Test Results Ig.'~Cm:fg      ICllKKl    ECSlklh      Q5KS~rgign 2-211        Initial Drag:    300                                      14.1    Pass ber:
SMPL-4      Activation:      .02          .012      Pass            .008    Pass Te    ype 16578                        4800          5190.1    % Load: 1.08    4961.1  % Load: 1.03 Serial Number:              Test Load:
Sl-2401<4                    300          20.4      Pass            13 0    Pass Mark Number                  Final Drag:
Capacity:      PSA-3          Lock up:      NIA Rplcmnt S/N                    Release:        NIA 2-219        Initial Drag:    300          18.1      Pass            12.7    Pass Tag Number:
SMPL-3      Activation:      .02          .011      Pass            .008    Pass Test Type 20259                        4800          4513.8    % Load: .94    4267.    % Load:.89 Serial Number:              Test Load:
CC-2061-101                  300          17.5      Pass            13.2    Pass Mark Number                  Final Drag:
Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:        NIA 2-222        Initial Drag:    2500          208.9    Pass            119.4  Pass Tag Number:
SMPL-1      Activation:      .02          .016      Pass            .015    Pass Test Type 7817                          40000          36490    % Load:.91      37300  % Load:.93 Serial Number:              Test Load:
Mark Number    SI-2412-29A                  2500          56.3      Pass            30 2    Pass Fina I Drag:
Capacity:      PSA-35        Lock up:        N/A Rplcmnt S/N                  Release:        NIA 2-224        Initial Drag:    37.5          4.4      Pass            6.6    Pass mber:
SMPL-1      Activation:      .02          .013      Pass            .01      Pass 10719                        520          532.8    % Load: 1.02    535.8  % Load: 1.03 Serial Number                Test Load:
Mark Number    CH-2081-685B Final Drag:      37.5        8.4        Pass            6.3      Pass Capacity:        PSA-1/2        Lock up:      N/A Rplcmnt S/N                    Release:        N/A 2-240        Initial Drag:    300          17.7    Pass            15.1    Pass Tag Number:
SMPL-3      Activation:      .02          .01      Pass            .008    Pass Test Type 16761                        4800          5147,4    % Load: 1.p7    4643.2  % Load: .97 Serial Number:                Test Load:
BF-3020-14B                  300          18.1      Pass            10 6    Pass Mark Number                Final Drag:
Capacity:        PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:        NIA 2-241        Initial Drag:    2500          272.8    Pass            251.4  Pass Tag Number:
PREY FAIL  Activation:      .02          .019      Pass            .018    Pass Test Type 7809                          40000          4237p    % Load: 1.p6    4211p  % Load: 1.05 Serial Number:              Test Load:
MSP102-33                    2500          276.8    Pass            222.6    pass Mark Number                  Final Drag:
Capacity:      PSA-35        Lock up:        N/A Rplcmnt S/N                    Release:        N/A 2-242        Initial Drag:    2500          148.9    Pass            121.5  Pass Tag Number:
PREY FAIL  Activation:        .02          .02      Pass            .018    Pass Test Type 7810                          40000          39050    % Load:.98      39540  % Load:.99 Number:              Test Load:
MS-4102-33                    2500          197.6    Pass            85.8    Pass umber                Final Drag:
Capacity:      PSA-35        Lock up:        NIA Rplcmnt S/N                    Release:        NIA
 
St. Lucie Unit 2 Snubber Test Results
                                              ~~CittJ:jg      ICl5jQD      BCSQlfR    Qgm~~          hiljtg, Tag Number      2-243        Initial Drag:    2500          211.2        Pass              195.1    Pass Test Type      PEV.FAIL      Activation:      .02          .017        Pass              .015    Pass Serial Number  7808          Test Load:      40000          39760      % Load:.99        39760    % Load: .9!
Mark Number    MS4102-287B  Final Drag:      2500          333.4      Pass              199 6    Pass Capacity:      PSA-35          Lock up:      N/A Rplcmnt S/N                    Release:        N/A Tag Number:    2-246        Initial Drag:    2500          216.4      Pass              203.2    Pass Test Type      SMPL-1        Activation:      .02          .018        Pass            .017      Pass Serial Number:  7814          Test Load:      40000          40580      % Load: 1.01    42140    % Load: 1X Mark Number    MS-4102-287A  Final Drag:      2500          238.6        Pass            223.5    Pass Capacity:        PSA-35          Lock up:      N/A Rplcmnt S/N                    Release:        N/A Tag Number:      2-268        Initial Drag:    300          63.3        Pass            64.6      Pass Test Typo        SMPL-1      Activation:      0 Serial Number:  61242/04      Test Load:      540          5635.0      % Load: 10.44    5469.5    % Load: 10.
Mark Number      B F4004-258                    300          43.1        Pass              42.6    Pass Final Drag:
Capacity:        LSG-3052        Lock up:      14.17        12.39      Pass              11.06    Pass R plcmnt S/N                    Release:      4.72          1.95        Pass            1.46      Pass Tag Number:    2-269          Initial Drag:    300          71.8        Pass            71.6      Pass Test Type      SMPL-1        Activation:      0 Serial 5lumber  61242/03      Test Load:        540          54657      % Load:          54254    % Load: 10I:
Mark bomber    BF-4004-258 Final Drag:      300          56.6        IMP              41 5      Pass Capac".I;      LSG-3052        Lock up:        14.17        12.95      Pass            10.07    Pass Rplcrt .t S/N                  Release:        4.72          1,90        Pass            1.45      Pass Tag tl aber:    2-315        Initial Drag:    2500          508.        Pass            315.6    Pass Test ~"po      PREV FAIL    Activation:      .02          .014        Pass            .015      Pass Serla< Number:  8458          Test Load:      40000          37440      % Load:.94      43720    % Load: 1.0<
Mark Number    MS4102-284    Final Drag:      2500          396.5        Pass            416 2      Pass Capac>ty;      PSA-35          Lock up:      N/A Rplcmnt S/N                    Release:        N/A Tag Number:    2-316        Initial Drag:    300          45.5        Pass,            46.3      Pass Test Type      PREV FAIL    Activation:      .02          .012        Pass            .006      Pass Serial Number:  25740        Test Load:      4800          48923        % Load    1019  44279      % Load: 9.;l Mark Number    BF-4004-38    Final Drag:      300          67.6        Pass            37.9      Pass Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                    Release:      N/A Tag Number:    2-322        Initial Drag:    17.5          14.6        Pass            15.8      Pass Test Type      PREV FAIL    Activation:      0 Serial Number:  61211/58      Test Load:      280          558.9      % Load: 2        556.6    % Load: 1.99 Mark Number    MS-7-R2B                      17.5          9.9        Pass            9.8      Pass Final Drag:
Capacity:      LSG-3018        Lock up:      14.72        11.58      Pass            9.03      Pass Rplcmnt S/N                    Release:      4.72          3.13        Pass            3.13      Pass
 
St. Lucie Unit 2 Snubber Test Results
                                          ~~CIJ:is[      1CEdQQ      BRRLjJJR    GQIEZRKigQ  ECgglfli 2-323        Initial Drag:    75            27,7      Pass            42.3 mber:
SMPL-1      Activation:      .02          .005      Pass            .004    Pass ypo Serial Number: 26064        Test Load:      1200          1277.9    % Load: 1.06    1242.1  % Load: 1.04 Mark Number    MS-3023-11 B Final Drag:      75            29.4      Pass            40.1    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-324        Initial Drag:    75            9.4        Pass            6.9    Pass Tag Number:
Test Type      SMPL-3      Activation:      .02          .007      Pass            .007    Pass Serial Number: 26005        Test Load:      1200          1273.4    % Load: 1.06    1286 5  % Load  1 07 Mark Number    MS-3023-53  Final Drag:      75            4.5        Pass                    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-325        Initial Drag:    75          20.2      Pass            21.3    Pass Tag Number:
Test Typo      SMPL-2      Activation:      .02          .015      Pass            .016    Pass Serial Number: 21596        Test Load:      1200          1294.2    % Load: 1.08    1208.7  % Load: 1.01 Mark Number    MS-3023-93  Final Drag:      75            14.4      Pass            20.6    Pass Capacity:      PSA-1          Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-332        Initial Drag:    300          47.9      Pass            39.1    Pass umber:
pe    SMPL-2      Activation:      .02          .014      Pass            .007    Pass 25526        Test Load:      4800          52187    % Load: 10.87    45882  % Load: 9.56 Se iai Number:
Mark Number    SI-2401-171  Final Drag:      300          55.5      Pass            35.3    Pass Capacity:      PSA-3          Lock up:      N/A Rplcmnt S/N                  Release:        N/A 2-334        Initial Drag:    17.5        3.4        Pass            7.7    Pass Tag Number:
Test Type      PREV FAIL    Activation:      0            1          Fail Serial Number: 61211/67    Test Load:      320            565      % Load: 1.77    585    % Load: 1.83 Mark Number    VRC-4-R3    Final Drag:      17.5          3.3        Pass            7.6      Pass Capacity:      LSG-3018      Lock up:      14.72          11.57    Pass            8.?7    Pass Rplcmnt S/N                  Release:        4.72        3.53      Pass            2.31    Pass
 
St. Lucie Unit
  ~
        ~  ~
2                            L-96-72 Docket No. 50-389 Fall 1995 Refueling Outage NIS-2 OWNER'S REPORTS        OF REPAIRS OR REPLACEMENTS
 
St. Lucie NIS-2 Reports NIS-2 Number            Date SL-2-7-001              10/21/94 SL-2-7-010              11/9/93 SL-2-7-011              11/8/93 SL-2-7-012              12/30/92 SL-2-7-014              4/19/93 SL-2-7-019              4/19/93 SL-2-8-001              7/28/94 SL-2-8-002              2/7/96 SL-2-8-003              7/12/95 SL-2-8-004              Working SL-2-8-005              Cancelled SL-2-8-006              Cancelled SL-2-8-007              Cancelled SL-2-8-008              6/28/95 SL-2-8-009              Cancelled SL-2-8-010              Cancelled SL-2-8-011              Cancelled SL-2-8-012              Working SL-2-8-013              12/12/94 SL-2-8-014              Cancelled SL-2-8-015              2/9/95 SL-2-8-016              Not used SL-2-8-017              6/22/95 SL-2-8-018              6/22/95 SL-2-8-019              6/30/95 SL-2-8-020              2/6/96 SL-2-8-021              7/12/95 SL-2-8-022              11/25/96 SL-2-8-023              1/22/96
 
St. Lucie NIS-2 Reports SL-2-8-024            i2/13/95 SL-2-8-025            11/22/95 SL-2-8-026            11/14/95 SL-2-8-027            11/14/95 SL-2-8-028            11/29/95 SL-2-8-029            11/29/95 SL-2-8-030            Cancelled SL-2-8-031            12/19/95 SL-2-8-032            12/4/95 SL-2-8-033            i2/13/95 SL-2-8-034            12/11/95 SL-2-8-035            12/11/95 SL-2-8-036            12/1/95 SL-2-8-037            11/25/95 SL-2-8-038            11/29/95 SL-2-8-039            11/25/95 SL-2-8-040            i2/2/95 SL-2-8-041            12/12/95 SL-2-8-042            12/5/95 SL-2-8-043            11/27/95 SL-2-8-044            12/12/95 SL-2-8-045            12/18/95 SL-2-8-046            ii/17/95 SL-2-8-047            ii/i3/95 SL-2-8-048            12/18/95 SL-2-8-049            12/13/95 SL-2-8-050            1/18/96 SL-2-8-051            11/29/95 SL-2-8-052            12/7/95 SL-2-8-053            12/7/95
 
St. Lucie NXS-2 Reports SL-2-8-054            11/2/95 SL-2-8-055            11/17/95 SL-2-8-056            12/27/95 SL-2-8-057            12/18/95 SL-2-8-058            11/14/95 SL-2-8-059            12/18/95 SL-2-8-060            11/21/95 SL-2-8-061            11/24/95 SL-2-8-062            11/20/95 SL-2-8-063            1/18/96 SL-2-8-064            Not Used SL-2-8-065            12/27/95 SL-2-8-066            11/29/95 SL-2-8-067            11/28/95 SL-2-8-068            12/27/95 SL-2-8-069            12/27/95 SL-2-8-070            1/22/96 SL-2-8-071            11/14/95 SL-2-8-072            Combined with SL-2-8-070 SL-2-8-073            11/20/95 SL-2-8-074            12/12/95 SL-2-8-075            1/22/96 SL-2-8-076            12/19/95 SL-2-8-077                      3ISIN st~ls~
SL-2-8-078            12/8/95 SL-2-8-079            1/2/96 SL-2-8-080            12/1/95 SL-2-8-081            11/30/95 SL-2-8-082            12/14/95 SL-2-8-083            12/14/95
 
St. Lucie NIS-2 Reports SL-2-8-084            12/18/95 SL-2-8-085            1/4/96 SL-2-8-086            12/27/95 SL-2-8-087            i2/i3/95 SL-2-8-088            11/29/95 SL-2-8-089            12/13/95 SL-2-8-090            11/25/95 SL-2-8-091            12/7/95 SL-2-8-092            i/2/96 SL-2-8-093            2/5/96 SL-2-8-094            2/5/96 SL-2-8-095            11/29/95 SL-2-8-096            11/29/95 SL-2-8-097            2/1/96 SL-2-8-098            12/11/95 SL-2-8-099            12/2/95 SL-2-8-100            12/8/95 SL-2-8-101            12/6/95 SL-2-8-102            11/29/95 SL-2-8-103            11/28/95 SL-2-8-104            11/28/95 SL-2-8-105            11/30/95 SL-2-8-106            Cancelled SL-2-8-107            1/4/96 SL-2-8-108            Cancelled SL-2-8-109            Cancelled SL-2-8-110            2/6/96 SL-2-8-111            Cancelled
 
PSL-1, NIS-2 TRACKING NO. S L -                  2  ~00 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                            As Required by the Provisions of the ASME Code Section XI II
: 1. Owner:                    Florida Power & Light Co:                Date:      10/21/94  ."
P.O. Box 529100                          Sheen      1  of 4 Miami, FL 33152 Unit:      2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:      NA Jcnscn Beach, FL 34957                    PCM    &#xb9;:  178-290
: 3. Work Performed By:          Florida Power & Light Co.                PWO&#xb9;: 4794 6501 South Hwy. A1A WO&#xb9;:        92040566 Jensen Beach, FL 34957 CWO &#xb9;:      NA          Process Sheet:    N/A
: 4. (a) Identification of System:      Intake Cooling Water Type Code Symbol Stamp          N/A ICW PP 2B                                          Authorization No.              N/A (b) Component Identification:
(Mark Number)                                                              Expiration Date                N/A (c) Code Class:    3
: 5. (a) Applicable Construction Code and Addenda: AsME SEcTtON III 1986 EDrraN No ADDfNDA Code Case: NA (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. IdcntiTication  of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other          Year        Replaced      ASME Code Component or      Manufacturer      Serial or Heat Board      Identification      Built        Repaired      Stamped Material                                No.          No.                                          or        (Y or N)
Replacement Pump              Byron          761-N-0002        NA    14,000 GPM          1980          Replaced (Less stuffing box)      Jackson                                              130 ft Pump            Johnston          901-A-3554        NA    14,000 GPM                      Replacement (Less stuffing box)        Pum                                                130 ft Column Bolting        Byron                              NA      A M SS-164                        Replaced Cap screws                                                    1  1/4-7unc '5 Jackson Column Bolting          BWID          Ht &#xb9;. M2943B/16    NA    ASME SB 164                    Replacement Cap screws                          & M2943B/17              1  1/4-7unc '5 Stud -Stuff Bx to      Byron                              NA      ASM'B.164                        Replaced 3/4 10uncx3
                                                                            ~
Discharge Head        Jackson                                            1/2 Stud-Stuff Bx to        Byron                Ht&#xb9;          NA      ASM'B 164                      Replacement          N 3/4    10uncx3 Discharge Head        Jackson            M9591B                        1 /2
: 7. Description of Work: REPLACE PUMP W/MODIFIED PUMP WHICH WILLPROVIDE IMPROVED LUBE WATER FLOW TO BEARINGS.
: 8. Tests Conducted:        Hydrostatic Other: VT I
                                                ~    Pneumatic VT 2 x      VT 3              ~
Nominal Operating Pressure (ISLT) x psig      Test  Temp.~'F
 
PSL-2, NIS-2 TRACKING NO. S              L-2      ~001 FORM      NIS-2 (Back)                              Sheet 2 of 4
: 9. Remarks:
: 10. Inspection Report Numbers:        NA APPLICABLE MANUFACTURES DATA AEPOttTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                Repair x  Replacement conforms to the rules of the ASME Code, Section XI.
A Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed ner  Owner's Designee, Title Date  ~2.t,        19  t'f CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                1 inspector's Signature                                  National Board, State, Providence and Endorsement Date
 
PSL-1, NIS-2 TRACKING NO. S L 0 7-~00          1 FORM NIS-2 01VNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASiME Code Section XI PL                            SUPPLEMENTAL SHEET
: 1. Owner.                  Florida Power & Light Co.            Date:        4/22/94 P.O. Box 529100 Miami, FL 33152                    Sheet:        3 of    4
: 2. Plant:                    St. Lucie Plant                    Unit &#xb9;:        2 6501 South Hwy. AIA Jensen Beach, FL 34957              P.O.  &#xb9;:      NA
: 3. Work Performed By:        Florida Power & Light Co.          PCM &#xb9;:          178-290 6501 South Hwy. A1A
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
National                                Replaced    AS ME Name of          Name of        Manufacturer                    Other          Year                Code Board B    d                                Repaired Component          Manufacturer      Serial No.                Identification      Built N                                        or      Stamped Replacement (Y or N)
Nut-Stuff Box to          Byron                            NA                              NA  Replaced 3/4 -tounc Hvy H Discharge Head          Jackson Nut-Stuff Box to          BWIP              Ht&#xb9;          NA 3/4 -10unc Hvy H NA  Replacement Discharge Head                            M2473BQ Nuts-Discharge          Byron                            NA      ASME SB-164            NA  Replaced Head to Pedestal        Jackson                                      14uncHex Nuts-Discharge            Nova              Ht&#xb9;          NA      ASME SB-164            NA  Replacement Head to Pedestal                            17155                1  4 unc Hvy Hex Studs-Discharge          Byron                            NA      ASME SB-164            NA  Replaced Head to Pedestal        Jackson                                    1"-Sunc-4 1/2" Studs-Discharge            Nova              Ht&#xb9;          NA      ASME SB-164            NA  Replacement    N Head to Pedestal                            22520                  1"-Sunc-4 1/2" Cap screws- Suet          Byron                            NA        AS ME B-164          NA  Replaced Bell to lmplr case      Jackson                                    3/4"-10unc-4" Cap screws- Suet          BWIP          Rei PO Doc      NA        ASME B.164            NA  Replacement Bell to Implr case                                                  3/4"-10 unc-4" Nuts- Suet          Byron                                      ASTM B-164            NA  Replaced Bell to Implr case      Jackson                                      3/4"-10 unc Nuts- Suet            BWIP          Ref PO Doc                ASTM B-164            NA  Replacement Bell to Implr case                                                    3/4"-10 unc Studs-Top Case            Byron                                      ASME SB164            NA  Replaced to Implr Case        Jackson                                    3/4"-10 unc-4" Studs-Top Case            BWIP              Ht&#xb9;          NA,      ASME SB164            NA  Replacement to Implr Case                          M2944B                  3/4"-10 unc-4" Nuts-Top Case            Byron                                                            NA  Replaced 3/4 - 1ounc to Implr Case        Jackson Nuts-Top Case            Byron              Ht&#xb9;          NA 3/4 -lounc Hvy H NA  Replacement to Implr Case        Jackson          M9539B Hex Nuts,            Byron                            NA      ASME SB-164            NA  Replaced Column Bolting          Jackson                                      1 1/4"-7unc Hex Nuts,            Nova              Ht&#xb9;          NA      ASME SB-164            NA  Replacement Column Bolting                              37165                1 1/4"-7unc Hx
 
PSL-I, NIS-2 TRACKING NO. S L -          2- 0 7-~00  1 FORM NIS-2 OAVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL                                  SUPPLEMENTAL SHEET
: l. Owner.                Florida Power & Light Co.          Date:      4/22/94 P.O. Box 529100 Miami, FL 33152                    Sheet:      4 of    4
: 2. Plant:                  St. Lucie Plant                    Unit &#xb9;:    2 6501 South Hwy. A1A Jensen Beach, FL 34957            P.O.  &#xb9;:    NA
: 3. Work Performed By:        Florida Power & Light Co.        PCM &#xb9;:        178-290 6501 South Hwy. A1A
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Manufacturer'ational Replaced      ASME Name of          Name of                                        Other        year                  Code Board                              Repaired Component          Manufacturer      Serial No.              Identification    Built No.                                  of        Stamped Replacement    (Y or N)
Capscrews-Column          Byron                          NA      ASME SB-164          NA  Replaced Top Case            Jackson                                  1 1/8"-7unc-5" Capscrews-Column          BWIP              Ht&#xb9;                ASME SB-164          NA  Replacement Top Case                          M33C2BG/111              1 1/8"-7unc-5" Hex Nuts-Column          Byron                          NA    ASME SB-164          NA  Replaced Top Case            Jackson                                    1 1/8"-7unc Hex Nuts-Column          BWIP              Ht&#xb9;                ASME SB-164          NA  Replacement Top Case                            M2107BG                  1 1/8"-7unc Stuffing Box          Byron                          NA    ASME SB-148          NA  Replaced Jackson                                    CDA 954 Stuffing Box          Byron              Ht&#xb9;        NA    ASME SB-148          NA  Replacement Jackson            M4659                  CDA 954 Stuffing Box          Byron              NF          NA                          NA    Replaced Plug            Jackson Stuffing Box          Byron              Ht&#xb9;                    SB-564          NA  Replacement Plug            Jackson          674TNE
 
PSL-1, NIS-2 TRACKING NO. S L 7 - ~01 0 FORM ibIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEi3IIENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:    11/9/93 P.O. Box 529100                        ShceL'      of Miami, FL 33152 Unit:    2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach, FL 34957                PCM    &#xb9;: NA 3 Work Performed By              Florida Power & Light Co.              PWO    &#xb9;: 5658 6501 South Hwy. A1A WO &#xb9;:    92055870 Jensen Beach,  FL 34957
'.    (a) Identification of System:      Reactor Coolant PRESSURIZER CWO    &#xb9;: NA          Process Sheet:
Type Code Symbol Stamp, N/A N/A V 1201 Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                        Expiration Date            N/A (c) Code Class:      1
: 5. (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification  Built      Repaired    Stamped Material                                  No.          No.                                    of      (Y or N)
Replacement SAFETY VALVE            CROSBY          N 59336                    NA          1 979    REPLACED        Y 0002 SAFETY VALVE            CROSBY          N59336        NA          NA          1 984 REPLACEME 0004 ALLTHREAD        NOVA MACHINE            HEAT  &#xb9;                SA- 193          NA    REPLACEME 1  1/4" X 8 UN X2A      PRODUCTS              67094                    GR B7 HEAVYHEX NUTS NOVA MACHiNE                    HEAT  &#xb9;        NA        SA-194          NA    REPLACEME PRODUCTS            8094962                    GR7
: 7. Description of Work: Replace valve and inlet bolting due to seat leakage.
: 8. Tests Conducted:          Hydrostatic Other: VT1 x
                                                  ~      Pneumatic VT2 x      VT 3  ~      Nominal Operating Pressure (ISLT) x
                                                                                  ~psig        Test  Temp.~'F
 
PSL-2, NIS 2 TRACKING NO. S L            7-    ~01 0 FORM      NIS-2 (Back)                                Sheet 2 of 2
: 9. Remarks:      A SATISFACTORY INSERVICE LEAIVGE TEST WAS PERFORMED AND ALL REPLACEMENT BOLTING WAS VISUALLYEXAMINEDBY A VT CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:        M93-369 APPLIDABLE MANUFADTUAE'SDATA REPORTS To BE ATTADHED Certificate      of Compliance We certify that the statements made in the report are correct and this              Repair x  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:        N/A Certificate of Authorization No.:      N/A
'Signed Owner or Owner's    esignee, Title Date  ~is<        . 19~
CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                1    F    Co  &#xb9;60 Inspector s Signature                                    National Board, State, Providence and Endorsement Date
 
JL.-l6-1992            13c 85  FROf'1    OPPD  CORP        S  PROC QA            TO                  9140 4684115              P. 82
  \
a CRb SOY VAl VF 4 4                                  8'8      CO      0 PALY W  I th~THAM,          MASS iORM NV 1 FOR SA,F E'Z'f h&#xc3;D SIAF ETY RRXJEF VAl            VES                      ClaC.MC-l ha required by che f rovislons ot cba Acti@ Code Rules DATA REPORT Safety and Safety Relief Valttee
: l. atanuractcua ay Cros              Valve    6 Crt e Co.          43 Kendrick        S  . hrrenthcttn      MA      2 DD-EP 86 JISXlXI, Oedda Pewaa        &
learns and Address Lldht    COOPaoy,      9.0.
JL    aaa, DOx DZ9990 I          d Q    acanufactured For        HiamL. Floride        33252                                    Ordertfo.18656>>22976%3926 Nllme and Address
* OWlcf                Florida    Potrer 6    Yd. ht    Company      St. Lucia Uttit        82 Namn and hddress
: 4. l:ocatinn af Plant                            da Spare        for    V>>1200, V-1201, V 1202 Serial No. N59336        00-0004    Dfa  ig No. DS  0 59336 Rev. E
: 5. Vahw identification a
Relief                                    eel dao  alta  K      plea alta            !alta    9 0    Oaa Qdety.safety Relief.lhllct.lhowar Actuated                          l hah              loch            laah          lao h 700                              F S. Scc pressuro      <psfa) t      Smpvrature 2129182      lbslhr 'tsteotu sat        ct        ~~ Qvsrp:useure        Blowdovyn    (pala)    4~    O<  Se>.
Stamped Cafztnt ty Htedfrhlhtattn Teat (iPQQ)  inlet          3750                          Complece Valve T. Tbe pnacsrzat      design, oOnsuuccton and vrorkrnanshtp comply vpich AgMK,'Code. Section      lg.
Do hddaoda Oha,            1
                        ~ddhdon            9        .hddaoda Date                                            ,Case No.
pressure Concaincruc or tzressure Rvcaining Cumpcznvnts Serial No.                                idatcrial s penl fioation
: a. Casczngs                                        identification                            including Type ot beads K60802-32-0004                    N9L522-33-0004                            ASIDE  SA35L Gr. CPS Body Bonnet P~r Scoc:k and Fotgtngs SalPPrar~ EOttQBt                          N91530 32-0004                            ARK    SALOS hloaxl ~                                  N91523-34-0008                            AS'458          Cx. 651 Disc Xneer      t                                2      5  0007                            A4 8 spring csasbers    K60807-32-0004 ~            I Adiusting Bolt                            N91532 35-0008                            ASM SA193 Gr. B6 Sp.        Poult                          N91527 33 0007                            ASHZ SA193 Gr. S6
          'RN8O6-33-0008 Spindl.e Bal3.                            h'9152 S                                    A$ . A276 T        e 440C Disc Holder                                N91524~36 0008                              AS'K SA637 Gr. 718 Bellowtr K60805 33-0005 Lcu shing                                  NSL525-34-0008                              Httyttcs  Satellite Alloy No.              68
 
                                                ~  ~
                                                    ~  I                                                  I  ~ ~  t I ~ ~
111'                              ~ ~  ~
~ ~ ~                                  1 ~
~ ~ ~
                                    ~ ~
                            ~ I    i:    ~ ~
                            ~  ~
                                                            ~      V  ~        I  ~
                                                                                      ~
                                                                                      ~
4
      ~, ~                            ~      \ I                                ~    ~  ~    ~
                      ~ ~ '      ~ ~                                                        ~    ~~  ~    ~
Vt    +i<I~ I    ~
                                                                                                                  ~ I  ~
                                                                          ~  ~
                                                ~    ~  ~      I  ~  ~
          ~      ~
                                                            ~ ~                              ~      ~    ~
                                                                ~    ~
Vl~
                                                                                                    ~    ~
 
PSL-1, NIS-2 TRACKING NO. S L 7 - ~01          1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.              Date:    11/8/93 P.O. Box 529100                        Sheet:    I of Miami, FL 33152 Unit:    2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O  &#xb9;:  NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.              PWO&#xb9;: 5657 6501 South Hwy. A1A WO &#xb9;:    92055869 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet:  N/A
: 4. (a) Identification of System:      Reactor Coolant Type Code Symbol Stamp      N/A V 1202 Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                        Expiration Date            N/A (c) Code Class:      1
: 5. (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of      Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification  Built      Repaired    Stamped Material                                No.          No.                                    or      (Y or N)
Replacement SAFETYVALVE              CROSBY        N 59336        NA          NA          1979      REPLACED 0003 SAFETY VALVE            CROSBY        N 59336        NA          NA          1987 REPLACEME 0005 ALL lHREAD 1/4"-8 UN-2A NOVA MACHINE          HEAT &#xb9;        'A        SA 193-74      1989 REPLACEME 1                      PRODUCTS          8094962                    GR B7 HEAVYHEX NUTS NOVA MACHINE                  HEAT &#xb9;          NA    SA-194 GR 7      1990 REPLACEME 1  1/4"-8 UN-2B      PRODUCTS              RL3
: 7. Description of Work: Replace valve and inlet bolting due to seat leakage.
: 8. Tests Conducted:        Hydrostatic Other: VT I x
                                                ~      Pneumatic VT 2 x        VT 3            ~    pstg    Test Temp.  ~'F Nominal Operating Pressure (ISLT) x
 
PSL-2, NIS-2 TRACKING NO. S            L-2    ~01 1 FORM      NIS-2 (Back)                                Sheet 2 of 2
: 9. Remarks:      A SATISFACTORY INSERVICE LEAKAGETEST WAS PERFORMED AND AU REPIACEMENT BOLTING WAS VISUALLYEXAMINEDBY A VT CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:          M93-370 APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate        of Compliance We certify that the statements made in the report are correct and this                  Repair +x  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:            N/A Certificate of Authorization No.:        N/A Signed or 0    er's Designee, Title Da1s  ~xl  Ia,      19~
CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                t inspector's    Signature                                  National Board, State, Providence and Endorsement Date
 
t.KUSIIY 'L'ALYF. F.SG Qlo CNOIIY YALV K CRaS'BY                                                            W ft  KHTHAM, MASS 8 6A GK CO                M  PANY FORM  gV I FOR SAFETY hgD SAFETY RELIEF VALVES                                      a C.-vC-l hs requited by the Provisions of the ASME Code Rules DATA REPORT Safety and Safety Relief Valves f tured By Crosby Va 1ve          & Ga      e . Co  .,  43  Kendrick        S t. Wrenthatn      MA game and Address HB-BP"66 hlceel Hc.            Order    No N74 620                Contract Daty 11/10/86 Vatlooal Board No.
Piorida      Power    &  Light      Co. PO Box OI 9 9 Manufactured For Ma>>, Florida              33102                                      Order go. C18656-79388 game and Address Florida    Power    &  Light      Company game and hddtess St. Lucie Unit          2    Jensen Beach,          Plorida
: 4. Locatton of Plant S  are              Serial go N59336-00-0005            Diawl% go      Ds-C-59336. Rev.      E S. Valve    Identification Safety Safety, Safety Relief.Pilot,Power Actuated
                                                                                  'loe oclllcc Slee 1. 531 lIIcll Slee lech lelel 3 lech ocIleI  6 lllch
: s. Set Ptessute (PSIQ)                2485                                                              700                          F Rated Tetnperatute 212,182 LBS/HR Sat Stm                                                                              4X  of S.P.
Stamped Ca)3acity~                                      tl          v Overpressute.        BIowdown (PSIQ)
Ilydrr static Test (PSIO) inlet        ~    50                          Complete Valve                        7 0
: 7. The material. design. construction and wotkmanship comply with ASME Code, Section                m.
No Addenda
                                                                                                              ,Case No.
Pressure Containing or Ptessute Retaining Components Serial go.                                  Material Specification
: a. Castings                                        Identification                              Including Type or Grade Body  K60802-33-0005                    N  1522-80-0005                            ASTH A 351      Gr. CF8H Bonnet
: b. Bar Stock and Forgings ZKtNIMPdK Bonnet                            N91530>>80-0005                            ASM," SA 105 goasle                                    N91523-36-0013                            ASTH A 458      Gr. 651 Disc  InSert                              N91526-80-0017                            ASTM A 458      Gr. 651 N
Vt 1531-3 spr>rig Nashers  K60807-80-0011 Adjusting Bolt                            N91532-35-0010                            ASME SA 193        Gr. B6 Spindle                                    N91527-34-0009                            ASME SA      193 Gr. B6 K60806-34-0009 Spindle Ball                                N91528                                    ASTH A 276 T          e 440C Disc Holder Assy                            N91524-38-0011                            AS."IE SA 637    Gr. 718 K60805-80-0009 Disc Bushing                                N91525-36-0011
 
12;02/92        09:29        50S      384 3152                      CROSBY VALVE EX(i Serial No. or                              Material Specification identification                            including Type or Grade
: c. Spring K60807-80-0011                          HX3108-0016
: d. Bolting
: e. Other Parts such as Pilot Components Bonnet Stud                                    81062                          ASME SA      l93 Gr. 87 Bonnet Nut                                      2370                          ASME SA 194        Gr. 28 Vle certify that the statements  made  in this report are correct.
Date                    19M~ Signed          Crosby Valve 6 GaSe Co.
Manufacturer By Certificate of huthoriaation No,        1878                  expires Se  tember 30        1989 CERTIFIChTE OF SHOP INSPFCTION I, the undersigned, holding a valid commission issued t% the National Board of Boiler and Pressure Vessel Inspectors and the State or province of                            and employed by Arkwri ht Mutual Insurance Com an                                                        have inspecce c e equ pment describe !n this ata Report on                                  19      and state that to the best of n:y knov:ledge and belief. the Manufacturer has constructed this equip.
ment in accordance with the applicable Subsections of hSMF. Section tll.
                'By signing chis certificate, neither the Inspector nor his employer makes any ivacranty, ex.
pressed or implied. concerning the equipment described in this Data Report.Fur!hermore, neither che Inspector nor his employer shall be liable in any manner for any personal injury or propercy damage or a loss of any kind arising from or connected with (his inspection.
Date                                                    Factory Mutual System Commis s tons (Inspector)                                    National Board. State. Province and No.>
 
PSL-1, NIS-2 TRACKING NO. S            L-2    ~01 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of'he ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.              Date:    12/30/92 P.O. Box 529100                        Sheet:    1  of Miami, FL 33152 Unit:    2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By:            Florida Power & Light Co.
PWO&#xb9;. 2702 6501 South Hwy. A1A WO &#xb9;:      92002640 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet:  N/A
: 4. (a) IdentificationofSystem:        Safety Injection Type Code Symbol Stamp      N/A (b) Component Identification:  V 3466                                        Authorization No.          N/A (Mark Number)                                                        Expiration Date            N/A (c) Code Class:    2
.  (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980
: 6. IdentiTication of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification    Built      Repaired    Stamped Material                                No.          No.                                    or      (Y or N)
Replacement Disc Insert          Crosby      N 89531-38-0                SA 479 Type      1 979      Replaced 11                      316 Disc Insert          Crosby      N89431-42-0                ASTM A-479        1992    Replacement 20                    T e 316 Nozzle              Crosby      N 90557-35-0                SA 479 Type      1979      Replaced 13                        316 Nozzle              Crosby      N 90557-38-0        NA        SA 479        1985    Replacement 22                    T e 316 Spindle            Crosby      K55444-37-0          NA        SA 479        1  979      Replaced 19                    T e 316 Spindle            Crosby      K55444-48-0                    SA 479        1991      Replacement 33                    T e 316
: 7. Description of Work: Replaced disc 8 nozzle due to leakage.
: 8. Tests Conducted:        Hydrostatic Other: VT I
                                                ~      Pneumatic VT 2 x      VT 3                                      ~'F Nominal Operating Pressure (ISLT) x
                                                                                  ~pstg          Test Temp
 
PSL-2, NIS-2 TRACKING NO. S              L-2      ~01 2 FORM      NIS-2 (Back)                                Sheet 2 of 2
: 9. Remarks:      A satisfactory leakage test was performed and witnessed by a VT 2 certified inspector.
: 10. Inspection Report Numbers:        M92-1538 APPLICABLE MANUFACTURES OATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this              Repair x    Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:    N/A Signed wner or Own r's Designee, Title Data  ~aa,          19  p~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Insurance of Norwood Mass.
have inspected the components described in this Owner's Report during operating cycle &#xb9;7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspsctor's Signature                                  National Board, State, Providence and EndorseRIents Date            - Iz
 
PSL 2, NIS 2 TRACKING NO. 8                L. 2. p 7~ay FORM VIS-2 OWNER'S REPORT FOR REPhlRS OR REPLACEMENTS As Required by the Provlafons of tbe ASME Code Section Xl
: 1. Owner.                    Florida Power 4, Light Co.                Os~:  CIPPt      s-P.O. Box 529100 Miami, FL 33152                          Shcct:    1  of  &
: 2. Plant:                      St. Lucic Plant                          Unit >>;    2 6501 South Hwy. AlA Jensen Beach, FL 34957                  PO.>>;  qgq9Q        - 98O& 0
: 3. cwork Performed By:          Florida Power    8c Light Co.          PCM>>:    4//t 6501 South Hwy. A1A Jcnscn Beach. FL 34957                  PWO>>:    ~/8 XA>>: </jg 8090                          Be30- /ddr        PA CW0>>: Bg+Q              Process Sheet: $  ~8- /yy/4'z Repair Orf,anizadon P.O. No., Job No., eet.
Type Code Symbol Stamp            N/A Authorization No,                N/A Expiration Date                  N/A
: 4. ldcntification of System:
PQ    5    t'R855UR f a8R
: 5. (a) Applicable Construction Code ASME Secuon ill, 1977 Edition, Summer 1977 Addenda.
f'r
                                                                                                                ~    Code Cases (b) Applicable  Edition Winter 1980 addenda.
of  Section
                                            ~ Xl Utilized Code Cases Repairs and Replacement    Components    1980  Edition, thru the 6, Identification of Components Repaired or Replaced and Replacement Components:
National                                Replaced          AS ME Name of            Name of            Manufacturer                    Other          Year Board                                  Repaired          Code Component            Manufacturer            Serial No.        No.
Identification      Built or          Stamped Replacement      (Y or N)
QOMSO&2 ldyyJ                                      H 6'kf nlO.
( Id9. 5 gg'~        CnJ6 ra6'CRwlh                                      f Z+Z6                    kPth~eitl r          N0 CaGA R      ClLM &tP2  2 < 0 ysJ                                k8N'tO.
I  0 Nut              fdhld&dknlU                                          ff "l't4                  kPVLKHHur            N0
: 7. Description of Work:            IHPC8 5 r OOS AHQ 68/tR                    rdA5 vugg'Pf-AMG M    'M6 PR855 URtKGie'- NRnJ5/flY.
: 8. Tests Cendusted:            Hydtostatte Other
                                                      ~      Pneutnatte Pressure            ps'est Nominal Operating Pressure Tem .                'F
 
PSL.2, NIS 2 TRACKING NO. S L ~ 2            ~ 07.~D FORM 'HIS-2          (Sack)                              Sheol 2 of W 9,    Remarks.      Q  f  )  gf    565&gNg~
I~+@p~+~gg ACUTE Ngg ggMwlC< g~CRPl8D gh    @Jeer Afiit EJ~
r gWASL8 I ff RoCSf/
PA.Q.K A~ neo.eP>PSC8          Vl- Z. WeS      far-f-Oa~ea OAj~P e.~O                  ~8.
APIsLICASLS MAHVCACTV%'tOATA RSPORIS TO SS ATTACh4O Certificate of Compliance we cenity thai lhe slalsmenls made in the reparl are carreal and this conforms to the rules of the ASME Code, Section XI.
QRspair      Q Replacemenl Type Code Symbol Stamp:          NIA Certificale of Authorization No.:      NIA Signed                                                                            O,ts      4.I t"1      i293 Owner or Owner      Des  oo, Titl~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiier and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright fnsurance of Norwood Mass, have inspected the components described in this Owner's Report during operating cycle 407 starting on
      'b(2t 3 and state that to the best of my knowledge and belief. the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this cerlificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in lhe Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property:damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's SlgrIalure                                  National Board. Stato, Providence and Endorsements Dale      D~
 
C          ~
1            4 J
                                                                        ~                                                                    ~          ~          ~    ~
                                                                    ~                          ~      ~
                                                                                                                ~                ~                              ~
                                                                                    ~    ~                                                                          ~ ~
                                              ~  I  .      ~
0            ~
                                                ~
                                            ~  I        ~
                                                                                                    ~
                                                                                                      ~                    ~      ~
                                                                                                                                                      ~  ~  ~
                            ~  ~                  ~ .          ~
I        ~
                                                                                                  ~
                                                                                                        ~
                                                                                                        ~          rar                          ~
                                                                                                                                                  ~
                                                                                                                                                                    ~      ~  ~  ~ ~
                                                                                                            ~      '
                                                                                                                        ~              ~  ~            ~
                                                                                                                ~          ~    ~        ~
s  .      ~
          ~ ~        ~                        ~        ~  I            I                        ~    I                                        t ~      ~                  ~ ~
    ~
        '    ~        ~          I  ~      ~                                ~ ~    I  ~    ~    I        i                        ~      ~ ~              'll      ~    ~
                      ':I .st            ~ .                          ~ r
                  'I    ~        ~  ~ ~                    ~,    I    ~  ~  ~ .  ~      I                      ~      ~ ~
                                                                                          ~ .  ~                                                                                      ~ ~
  ~  ~ r
                                                                                                                                                                                          ~ '
I~SR'                                                  rr                                . gg L
HMH
                                                                                  %MR                                                                                            L
                                                                                                                                                                                'RR x
      ~:          ~    ~        o      ~
HMH A
                                                                                                                                                  ~:,
A
                    ~    ~                                                                                                ~        .      ~              ~
 
PSL.2, NIS 2 TRACKING NO. S L - 2 ~ 0                9.~OI FORM NIS-2 (Sack)                                            Sheet 2  of&
: 9. Remarks:        L Q  g  (    I 0    68      f'GP.f-af.'/    I E~~      75M      '( F ~I C1 ( OUt'.
APKCASLS LiH4UfAClUAE'S OATA 22EPOATt TO OS ArTsLCHisO Certificate of Compltance We oehtty that Ihe stalemenls made In the report are correol and lhts              Q Repatr@J          Rsplaoemenl conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Autho    'ion    No.:  N/A Signed Ownor or Owner's    eslgn o, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright fnsurance of Norwood Mass.
have inspected the components described in this Owner's Report during operating cycle NO'7startlng on .
95 and state that to the best of my knowledge and belief, the Owner has performed examinations and                  '5) and taken correctivo measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning Ihe examinations and corrective measures descibed in the Owner's Report.
Furthermore, neithor the inspector nor his employer shall be liable In any manner for any personal injury or property:damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Stgnature                                  National Board, State, Providence and Endorsements Date    C'
 
e PSL-1, NIS-2 TRACKING NO. S            L-2    ~00  1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                          As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.              Date:    7/28/94 P.O. Box 529100                        Sheet:    I of Miami, FL 33152 Unit:    2
: 2. Plant:                      St Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA 3  Work Performed    By'lorida Power &, Light Co.                      PWO&#xb9;: 0074 6501 South Hwy. A1A WO &#xb9;:    94010469 Jensen Beach,  FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identificationof System:    Aux Feedwater Type Code Symbol Stamp      N/A V09119                                          Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda:      ASME SEcr III 1974/SuMMEtt 76 Aoo        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or      Manufacturer      Serial or Heat    Board    Identification    Built      Repaired    Stamped Material                              No.            No.                                    or      (Y or N)
Replacement Pipe PLug        Pacific Valve                                    ASME                    Replaced 1/2"                                                          SA 105 Pipe Plug        Tioga Pipe          Heat &#xb9;          NA        ASME          1991    Replacement 1/2"          Ca itol Mf  .      2F3720                    SA 105
: 7. Description of Work: REPLACE 1/2" PIPE PLUG FOR VALVE DUE TO LEAGAGE FROM PIPE THREADS.
LINE  &#xb9;  I-4-BF-29
: 8. Tests Conducted:        Hydrostatic Other: VT I
                                              ~
                                              'T      Pneumatic 2 X      VT 3            ~
Nominal Operating Pressure (ISLT) X petg    Teet  Temp.~'F
 
PSL-2, NIS-2 TRACKING NO. S              L 0-    ~00  1 FORM      NIS-2 (Back)                              Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:      MM94-1080 APPLCABLE MANUFACTURES OATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this              Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed ner    Owner's Designee, Title Date      I  Z,      19~9 CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's  Ig ature                                National Board, State, Providence and Endorsement Date
 
PSL-1, NIS-2 TRACKING NO. S L 8 -              002 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 02/07/96 P. O. Box 529100                              Sheet:  1          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: NY 422537 6501 South Hwy. AIA                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO    &#xb9;: 8218
: 3. Work Performed By:                  Florida Power & Light Co.                      WO &#xb9;: 95032001-01 6501 South Hwy. A1A                            WCD &#xb9;: 'N/A Jensen Beach,  FL 34957
: 4. (a) Identification of System        CCW                                        Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVETCV-14MB                                          Expiration Date N/A (Mark Number)
(c) Code Class:
: 5. (a) Applicable Construction Code and Addenda:            ASME 1974 S 1974 ADD. Code Case:                    N/A (b) Applicable  Edition of Section XI  for Repairs and  Replacement Components: 1989 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other      Year      Replaced      ASME Code Component or        Manufacturer Serial or Heat          Board    Identification Built Repaired or        Stamped Material                              No.            No.                              Replacement      (Y or N)
VALVE- 30"        HENRY PRATT SA 516 WR 70            CO.            D0095-1-1        N/A            N/A        1979    REPLACED          YES VALVE-30"        HENRY PRATT                                    RIR&#xb9; 3K-0347 SA 516 - GR 70          CO.            D0095-1-2        N/A        & 3RB-1430    1979 REPLACEMENT          YES STUDS- SA193        ALLIED NUT 1 1/4-8UN2A        AND BOLT            62413          N/A      RIR&#xb9; 2J-0232    1994 REPLACEMENT NUTS- SA194        ALLIED NUT 1 1/44UN2B          AND BOLT          E97187          N/A      RIR&#xb9; 2J4761 1993 REPLACEMENT
: 7. DESCRIPTION OF WORK:                VALVE REPLACEMENT PER DISPOSITION OF STAR 950764.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) [ X]
Other: VT1    []        VT2[X]            VT3[]              sYsTEM PSIG        Test Temp.        sYsTEM F Hold Time 4 HDURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          002 FORM NIS-2            (Back)                  Sheet    2  of
: 9. Remarks            ISLT WAS SATISFACTORILY PERFORMED AND WITNESSED BY A VT2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:            M95-452 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this            [ ] Repair      [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date      +I Owners or Owner's    sign    Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Ownei's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements J
Date
 
0
                        )(eat! g ta<<PY)        tt Ctttylf)ClalC ttt.'tt)CRS fs Aeetoireaf lay lt c tco)rhinos Lbhietette)CS Ly 3))Cm) )XCCC. CO..
aeasILRL<< J 9RP:pet If<<or<<eon)5!))Cresset 'I Certstacrtc ttnlCke) s      ~
Le."yA I:LpOIIT t Ult ot atsc ASt tC Coafr hS C 5 )a>a,g ~JATO) l'UCllhll I'Uf573 0 5 Vf:VC'e Sects)et LLC)slsr.
A en cM CrnJ~)
                                                                                                                                                              )
: 7. Leo&rite Stoa                  XloTLeto        J'os:ep..(.J        5R)tt        Ca            ...SJ.<< ltsc5p Ucaac p'a~e e<      ra  eve ~ temsesee ~ ) ~ lwegtl "r" n XOX~P<<reC~XPXi&
S, CO 4$ O'I elf<<are rc tsre aev raur nr
                                                                                                  ~rt L~                  S.          ~r"                  ~t S4e~g" c.n
                    .  ')
c cr I;o.~
I code) tto NX Ct )  tt CeetlPecote Scat<<I Hut<<Ice's Rct) lc) Cosset~
tt own              gl C)rocatny                                  CI) kotl.          CO) Yc  or So)cart oc Type                        Mcs                              ttc).                      tto<<)c)              Close              CcL )to
                            ))a~I'eea                                                                                  sii i l
        ~  a se i- e                    II s              e-                                                      )I A            1979 "A
0}
Cq
                                                                                                                                                                                ~ ~ ~
                                                                                                )ySI)''rg~
gi~LC~~~s                          Lrvetvyn)ct Syotcra wp 0          r                                                      <<vs<<I L Ccocn Cceaef)Cons                        tv<<ceo<<act                            ttc~e~v el
                                                                                                                                ~
                                                                                                                              <<vv>> sa
                                                                                                                                    ~  +
                                                                                                                                                \
u            aae                      ~
e) i<<
            )L Colt'Lt~af preSSaeee                                                                                                          ~      v  ~                                            ~
ZZ$                pal    OC  %OS.                                                    ~
                                                                                                                                                                  '                    s~  ~
                                                                                                                                                                          ~ ~
L tycssasre p<oXny farces
: 4) Catt~no
                  <<a<< <<Le~r
                              ~~
s'-
                                    )t. rL tto tabb LtsttA1 Socc.
KLt'.~I
                                                                            ~
c New                            lou Octa e    o Rcenoets e
  ~  ~  i c
~      ~
    ~      ~  a
: n.    'T5<<
Nr~~s
' ';Ta~eh)elf t 1
                          .<<lie<<la      h.tifLave i iafthr...,
C          )litt SL S"ha 1'1"i ~ t)30 a<<Jl.
V
                                                                                                                      ~      st  u)s inc te ~ ta                              [QJfig!s'1
                  ~
        ~
                          \~
                  ~  ~
      ~    c            ~ a'<<n  5    a  e ~  ie  ~ i,      sessL's%'            e    '        s Ctl lee      ns)no&I. cpcect~l          i.~s o Pg.                                                    ~ ~
                                                                                                                                                                      ~        ~
1  Siiltl ~ i 11 i'I ha fa r) 1 ea          ~                        I<<, lt I
                                                                        ~  e-  1 re  a    roose'.      nasg Le sscaf pr        'tal ltl I    sr  I  C IO      )1  lt    5 J tref<<sana, Inn tre k ans I, 7 ~ rae S e ~ teu'srtv                As pasn la saa'area<<I          en co    ls  ~ tv  rt, mat  llt  a  <<ls lhra    Ia  1~  nr Iree ~ I as    1 nnss  t<r a f 1!assis I' as "so<<fast I a,i<<at 1' Ives 1
                        ~
it    lv., Rl    ~ ~  ~  ~ ~    .'~ ~  'a ah,            ~ ~  ~,  ~ 1      ~
                                                                                                                                              '              'll''
 
0
      ~  >>            ~ '
f0 }.st.e'se I last-)
htse'L    N  1                                  t.l,i<<IMf<eo. taL                                ~ ~,4    I.flic/I r                      rt rLI.I.S IS l>>CII Jl B~g<<trs Cover                      aatt            8/! l'}3 C:W. BI                                  S. C I n el 1  l L ~lr '4        ~
Thur          Pln SC SS                                                        Trays    tr Iep                        Mech<< 5                                fl(s    F~<<  ld
                                                        ~thr.
                                                                                                                            's is><<f y
        ~ c    t I<<g Ehher Pa<<ss S  A'7                                      nhns            hi J'n e B<<s<<I~ She)T S/S      II elt~eec I                                        '!  >lb 1,;t.        Fg                            I"'            ~C                      see>>    beets."Hl'.I I/Il clleele              IISS          AI            ss gl<        a%      10                          lth'eh>>    Steel                      sl Te LQ!CClsyega Bgt~CfsvOC                        <<ss)1
: e.  ~>>                        421                  cs.      I>>cc;:            c.                  ~o CKR) IFCATt CF CO)IVI.tWMS 4 .'.;-s s~                                              p;~ ee <<hsee.
                                                                                                                                        .~Cff<<~lc~
eels  ty cehse    tehe  stsetl-crrs sneer V'}ye ara awccc      anl    f>>se SL 5                          co ffcsrns ea    ae    ruses ot yes:-'I              <<~      I<<>> ' t                      tlrcc  cc>>ee>>              Q    I      cc  0  . I  f Acct>>*es            w<<Ills    es<<set
                                                              .c          c>>e ee.                  I                            4>>
5'dne<<)    Dtfsty..f!att  rs c<<ef 'LIsss Cw ses p<<es htt Q p<<shscce.hf'case                    of pfaaariA.tf N<<h              Jblsil                      se use stfe              'lfne          ssn+eee      ~cs    very OnC pa  ".3L CMT Fff-.fl)fe)s) 4}P aasfa))
aeth3/1  bstorrner~          On fde          asere T'catt Co 4O) S~'.h)and~h,                                                  Queo~ca      Tf,~ff)l ec        ~>>tcesscccycehleecyccc~Q I  'I      .Ser ': CC>>cy>>CCIC>>chefye&ehe cecal tcs>>Mc                                          soy s.          -&SIB                                                                        ~  ~
St/esc en@'jt 5 ch>>fag tcscsc              I///I I!) Bb}nehrrs net rs.tubed. LM rhsms dbf (})
Sy    r.e/h..
o 1}y.
                                                                                                                                      \      ~    ~
s:ER)lFIC'!YE <<C SIIG> LISPS)ION
                                        '4
)I she undessusnehh hah.".rg a us If c"1 encl}stun fshued hp the tf It:c<<LSI go:rd                                            a  t'oger asst ptsshure Vessel bifpe.toes
~ nd she Sssse or l'IIs<<fr Lc oA) ).L!'Lo N                    l                                        end eneltoted by - V..~..IS            LT~AJ        f;Qe Ot  ~lar        1}rc~7e~nna                                                llsie In}peel>>d ttfa Nufrp <<}r T the dceclche f 411 ttl 5 Ossa tfcpcet SbuC<<ed Shie punlffh Or >>S'                        bi OCecsf Jsr e Shith the hgh'b COde, Seht                O<<S O.
f}y I/gn>>fg sh}s ersri(eCS}t ne fhl'1 ther                      tcshfheetnr  rur Hs cn pfcyer msles ally sir SntP      hy            CSPfceStd    or beIF} et  <<er~        3 the e<<tufpment <<frserihed 'In OIIS Oaea Arpole. Futthercner 4, neither the tnt 1>>>>cror ner his enchfeyes chil be 14h'e t<<1 Snf manner t cr any p recech.d tn,ury Or pl.q iuty Itamrge Or a Ia.S Cf eny Send enS nff teem Or Cerneded Sn}'h fhft fnfpest} <
( ji ~X:-
asf..>
stt.'sh    i~'8/tr. lic        ~ .~
r'er I'
I) ~>.
                                                        +>vs. r SDI                  .. c'e}nile'es bslss    +    +gag  frl rl nr    n el<< less, ssa  rl'll
 
PSL-I, NIS-2 TRACKING NO. S          L-2    ~00 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                            As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:    07/12/95 P.O. Box 529100                        Sheet:    1  of Miami, FL 33152 Unit:    2
: 2. Plank                        St. Lucie Nuclear Plant 6501 South Hwy. AlA                P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.              PWO&#xb9;: 2032 6501 South Hwy. A1A WO &#xb9;:    91026981 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identification of System:    Chemical 3 Volume Control Type Code Symbol Stamp      N/A V2328                                        Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda:      ASME SEGT. Ill 74 EDinow/No ADDENDA      Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. IdentiTication of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or      Manufacturer      Serial or Heat    Board    Identification  Built      Repaired    Stamped Material                                No.          No.                                    or      (Y or N)
Replacement Relief Valve      Crosby Valve                                      SA 351                  Replaced N 59200.00-0003            CFBM ( BODY)
Relief Valve      Crosby Valve            S/N                      SA 351      1988    Replacement N 59200.00-0005            CFSM ( BODY)
: 7. Description of Work: Replace charging pump 2C relief valve due to body to bonnet leak
: 8. Tests Conducted:          Hydrostatic Other: VT I
                                                ~      Pneumatic, VT 2 X      VT 3            ~
Nominal Operating Pressure (ISLT) X psig  Test  Temp.~'P
 
PSL-2, NIS-2 TRACKING NO. S              L-2    ~00 3 FORM      NIS-2      (Back)                          Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        MMg5 44g APPLICABLE MANUFACTURE'S OATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                  Repair +XReplacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:            N/A Certificate of Authorization No.:        N/A Signed                                    4ukg~    u I                            Date                  19 t%
Own    or 0    r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations arid corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                      F        &#xb9;  0 inspector's Signature                                    National Board, State, Providence and Endorsements Date                                    19~4
 
PSL-1, NIS-2 TRACKING NO. S            L-2    ~00 8 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.              Date:    06/28/95 P.O. Box 529100                        S heeL'      of 2 Miami, FL 33152 Unit:      2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.              PWO&#xb9;: 0236 6501 South Hwy. A1A WO  &#xb9;:    94013291 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identificationof System:    Reactor Coolant Type Code Symbol Stamp    N/A Authorization No.          N/A (b) Component Identification: V2345 l7-0 s-r0D                          Expiration Date            N/A IMsrkNemrrer)      (31re Nljg I                    re)I (c) Code Class:    2
: 5. (a) Applicable Construction Code and Addenda: ASME SFcr III 1974 Eomow No AooEwoA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer      National      Other        Year      Replaced    ASME Code Component or      Manufacturer      Serial or Heat    Board    Identification    Built      Repaired    Stamped Material                              No.            No.                                    or      (Y or N)
Replacement Disc Insert      Crosby Vaive            S/N                      SA 479        1 974      Replaced 2 x 3/600 psig                      N89431-38-0012                T e 316 Disc Insert      Crosby Valve            S/N            NA        SA 476        1 993    Replacement 2x 3/600psig                          89431-43-0024                T e31
: 7. Description of Work: Replace disc due to leakage, valve sent to stores for use as spare.
S/N    N59197-00-0001
: 8. Tests Conducted:        Hydrostatic Orher:VT1
                                              ~  VT2 Pneumatic VT3 Nominal Operating Pressure (ISLT) X.
                                                                                ~psIg        Test  Temp.~'F
 
PSL-2, NIS-2 TRACKING NO. S            L-2          ~008 FORM      NIS-2 (Back)                              Sheet 2 of
: 9. Remarks:      Q  ~@do>            VW-K M~% pQP&rnhgg,.
2'0.
Inspection Report Numbers:      II/t, IVI,C,Q - ( QQ APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate    of Compliance J
We certify that the statements made in the report are correct and this                Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed ner sg. P r Owner's Designee, Title rv    - t6                    Date      l    t,    19~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              1    F  Com &#xb9;60 Inspec or's Signature                                  National Board, State, Providence and Endorsements 19  92
 
PSL-1, NIS-2 TRACKING NO. S L            8-  ~01 3 FORM NIS-Z OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                            As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:    12/12/94 P.O. Box 529100                        Sheet:    I of Miami, FL 33152 Unit:    2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA 3  Work performed By            Florida Power & Light Co.              PWO&#xb9;: 2089 6501 South Hwy. A1A WO &#xb9;:    94029274 Jensen Beach, FL 34957 CWO &#xb9;:    NA        Process Sheet:  N/A
: 4. (a) Identification of System:    Chemical 8 Volume Control Type Code Symbol Stamp    N/A CHG-PP-2B                                    Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                        Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda: ASME Sect tll 1971 EDmow W72 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replaccmcnt Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or      Manufacturer      Serial or Heat    Board    Identification  Built      Repaired    Stamped Material                                No.          No.                                    or      (Y or N)
Replacement Stuffing Sox        Union Pump              SN                    SA 479        1974      Replaced N73 2246-602                  Gr 410 Stuffing Box        Union Pump      SN33760813300      7607      SA 479.      1985    Replacement      N Ht&#xb9; 53046                  Gr 410
: 7. Description of Work: Replace stuffing box assembly due to leakage.
: 8. Tests Conducted:          Hydrostatic Other: VT  1
                                                ~      Pneumatic VT 2 X      VT 3  ~      Nominal Operating Pressure (ISLT) X
                                                                                ~pstg        Test  Temp.~'F
 
PSL-2, NIS-2 TRACKING NO. S              L-2    ~01 3 FORM      NIS-2    (Back)                          Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.,
: 10. Inspection Report Numbers:      MMg4-20g4 APPLCABLE MANUFACTURES DATA REPORTS To BE ATTACHEO Certificate      of Compliance We certify that the statements made in the report are correct and this              Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed                                      SCCA+    V    (S (                pe1eDc1-    1S,      19~7 Owner    Own  'esignee,  Title CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              7            m&#xb9; Inspector's Signature                                National Board, State, Providence and Endorsement Date
 
ee PSL-g, NIS-2 TRACKING NO. S            L-2    ~01 0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:    2/9/95 P.O. Box 529100                        Sheet;    1  of Miami, FL 33152 Unit:    2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach, FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By:          Florida Power &, Light Co.            PWO&#xb9;: 2488 6501 South Hwy. AlA WO &#xb9;:    95003025 Jensen Beach,  FL 34957 CWO &#xb9;: NA            Process Sheet:  N/A
: 4. (a) Identificationof System:      INSTRUMENTAIR Type Code Symbol Stamp      N/A MD -IA-15-R1 Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date            N/A (c) Code Class:    2
: 5. (a) Applicable Construction Code and    Addenda:,                  NA                      Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other        Year      Replaced    ASME Code Component or      Manufacturer        Serial or Heat  Board    Identification    Built    Repaired    Stamped Material                                  No.          No.                                    or      (Y or N)
Replacement HANGER(U-BOLT) BERGEN-PATER                                NA        PART&#xb9;          NA      REPLACED        N att                                        6500 HANGER(U-BOLT) BERGEN. PATER                                          RIR  &#xb9;        NA    REPLACEM          N CN                                      3AF-4708
: 7. Description of Work: REPLACE U BOLT WHICH WAS FOUND MISSING.
LINE  &#xb9;  2-IA-75
: 8. Tests Conducted:          Hydrostatic Other: VT I
                                                ~    Pneumatic VT 2        VT 3 X Nominal Operating Pressure (ISLT)
                                                                                ~pstg        Test  Temp.~'P
 
PSL-2, NIS-2 TRACKING NO. S L -               2    ~01 0 FORM      NIS-2 (Back)                                Sheet 2 of 2
: 9. Remarks:      VT-3 PERFORMED BY QC-EXAMINATIONOF U-BOLT INSTALLATIONONLY (S L-2-8-01 5)
: 10. Inspection Report Numbers:        MM95 088 APPLCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this          /Repair      X  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed w    or 0  er's Designee, Title Date    ~<I, t9~l CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                                &#xb9; inspector's Sig ature                                    National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO. S L 8 - ~01 7 FORM NIS-2 OWNERtS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power  & Light Co.              Date:    06/22/95 P.O. Box 529100                        Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                  P.O.&#xb9;:    NA Jensen Beach, FL 34957                  PCM    &#xb9;:  015-295M
: 3. Work Performed By:          Florida Power & Light Co.              PWO&#xb9;: 2549 6501 South Hwy. A1A WO &#xb9;:      95003598 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification of System:      Chemical 6 Volume Control Type Code Symbol Stamp      N/A LCV-2110P                                      Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda:      ASME SEc1'III 1971 Eomm/W72 Aoo          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
Type of              Name of      Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification      Built    Repaired    Stamped Material                                No.          No.                                      or      (Y or N)
Replacement Spindle / Plug        Control          Heat No                    SA 479        1992      Replaced 2" / 1500lb      Com onents Inc        606083                      GR 316 Spindle / Plug        Control          Heat No                SA 479 SA316      1995    Replacement 2" / 1500lb                    Inc          4                  Stellite 6 C
: 7. Description of Work: Replace stem/plug assembly which was found damaged
: 8. Tests Conducted:        Hydrostatic Other: VT I
                                                ~      Pneumatic VT 2 X      VT3 Nominal Operating Pressure (ISLT) X
                                                                                ~pstg          Test  Temp.~'3
 
PSL-2, NIS-2 TRACKING NO. S L -             2  ~01 7 FORM      NIS-2 (Back)                               Sheet 2 of 2
: 9. Remarks:         A satisfactory inservice leakage test was performed and witnessed by a VT -2 certified inspector.
: 10. Inspection Report Numbers:           MM95-41 9 APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                  Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:             N/A Certificate of Authorization No.:         N/A Signed Own      or 0 0
er's Designee, Title Data  ~27,           19~
CERTIFICATE OF INSERVICE INSPECTION I, the  undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                1            m&#xb9; Inspector's    ignature                                    National Board, State, Providence and Endorsements Date                                    I 19 CS
 
PSL-I, NIS-2 TRACKING NO. S L 8 -            ~01 8 FORM NIS-2 OYVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:    06/22/95 P.O. Box 529100                        Sheet:    I of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:    NA Jensen Beach,  FL 34957                PCM    &#xb9;:  015-295
: 3. Work Performed By:            Florida Power & Light Co.              PWO&#xb9;: 2685 6501 South Hwy. A1A WO &#xb9;:      95005451 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identificationof System:      Chemical & Volume Control Type Code Symbol Stamp      N/A LCV.21100                                      Authorization No.          N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda:        ASME SEcT III 1971 Eornow/W 72 ADO        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Rcplaccmcnt Components: 1989 Edition.
: 6. IdentiTication of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification    Built      Repaired    Stamped Material                                No.          No.                                      of      (Y or N)
Replacement Seat Ring            Control              NA          NA          SA 479                    Replaced 2" /1500 Ib                                                          GR 316 Com onents Inc Seat Ring            Control            Ht No        NA      SA 479 SA316      1994    Replacement 2 /1500lb      Co    o                                          Stelllted Spindle / Plug        Control              NA                      SA 479          NA        Replaced 2" / 1500lb                                                        GR 316 Com one ts Inc Spindle / Plug        Control            Ht No                  SA 479 SA316      1995    Replacement 2" / 1500!b                                                      Stellite 6 Com      n      Inc
: 7. Description of Work: Replaced seat ring and spindle / plug assembly.
: 8. Tests Conducted:          Hydrostatic Other:VT t
                                                ~  VT2 Pneumatic x      VT3 Nominal Operating Pressure (ISLT) x
                                                                                  ~pstg        Test  Temp.~'F
 
PSL-2, NIS-2 TRACKING NO. S              L-2    ~01 8 FORM      NIS-2 (Back)                                Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT -2 certified inspector.
: 10. Inspection Report Numbers:        MM95-438 APPLICABLE MANUFACTURES DATA REPDRTB To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                Repair x    Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed                              se.         S''tst                          Date      <~ +7, 19~
Owner o    wn  'esignee,    Title CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requiremenls of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              1            m&#xb9;   0 Inspector's Signature                                  National Board, State, Providence and Endorsements 19~


PSL-I,NIS-2TRACKINGNO.SL-2-8-~018FORMNIS-2OYVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:LCV.21100(MarkNumber)(c)CodeClass:24.(a)IdentificationofSystem:Chemical&VolumeControlDate:06/22/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:015-295PWO&#xb9;:2685WO&#xb9;:95005451CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASMESEcTIII1971Eornow/W72ADOCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandRcplaccmcntComponents:1989Edition.6.IdentiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialSeatRing2"/1500IbNameofManufacturerControlComonentsIncManufacturerSerialorHeatNo.NANationalBoardNo.NAOtherIdentificationSA479GR316YearBuiltReplacedRepairedofReplacementReplacedASMECodeStamped(YorN)SeatRing2/1500lbSpindle/Plug2"/1500lbSpindle/Plug2"/1500!bControlCooControlComonetsIncControlComnIncHtNoNAHtNoNASA479SA316StellltedSA479GR316SA479SA316Stellite6NAReplaced1995Replacement1994Replacement7.DescriptionofWork:Replacedseatringandspindle/plugassembly.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)xOther:VTtVT2xVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~018FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-438APPLICABLEMANUFACTURESDATAREPDRTBToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairxReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedse.S''tstOwnerown'esignee,TitleDate<~+7,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequiremenlsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissions1m&#xb9;0NationalBoard,State,ProvidenceandEndorsements19~
O.
O.
PSL-1,NIS-2TRACKINGNO.SL-2-0-~019FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)Componentidentification:ChargingPump2A(MarkNumber)3.WorkPerformedBy.FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL349574.(a)IdentificationofSystem:Chemical8VolumeControlDate:06/30/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4099WO&#xb9;:95011304CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:25.(a)ApplicableConstructionCodeandAddenda:AsMEsEcTIII74Eo/SuMMER74AooCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalSerialorHeatBoardNo.No.OtherYearIdentificationBuiltReplacedASMECodeRepaired"Stampedor(YorN)ReplacementStuffingBoxStuffingBoxNuts(Coverflange)11/4Rune-28UnionPumUnionmUnionPumHeatNo34NANANASA479Te304SA4794SA194Gr6NANANAReplacedReplacementReplacedNu'ts(Coverffeoge)11/4"4unw28NovaHeatNo81ASMESA194NAReplacementN,Nuts(Valvecover)11/44unc-28Nuts((Valvecover)11/44unc-28UnionuNovaNAHeatNo871201NASA194GrASMESA194Gr6NAReplacedReplacement7.DescriptionofWork:Replacedstuffingboxduetoleakageandnutsduetogalling.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VTIVT2XVT3~pstgTestTemp.~'F  
PSL-1, NIS-2 TRACKING NO. S L            0-   ~01 9 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                     Florida Power & Light Co.             Date:     06/30/95 P.O. Box 529100                        Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                       St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:     NA Jensen Beach,  FL 34957                PCM    &#xb9;: NA
: 3. Work Performed By.          Florida Power & Light Co.              PWO&#xb9;: 4099 6501 South Hwy. AIA WO &#xb9;:     95011304 Jensen Beach, FL 34957 CWO  &#xb9;: NA          Process Sheet: N/A
: 4. (a) Identification of System:      Chemical 8 Volume Control Type Code Symbol Stamp      N/A Charging Pump 2A Authorization No.          N/A (b) Component identification:
(Mark Number)                                                        Expiration Date            N/A (c) Code Class:      2
: 5. (a) Applicable Construction Code and Addenda:       AsME sEcT III 74 Eo/SuMMER 74 Aoo Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of      Manufacturer    National      Other        Year      Replaced    ASME Code Component or        Manufacturer      Serial or Heat    Board    Identification    Built      Repaired  "Stamped Material                                No.           No.                                     or      (Y or N)
Replacement Stuffing Box            Union                            NA        SA 479          NA      Replaced Pum                                      T e 304 Stuffing Box            Union            Heat No        NA        SA 479          NA    Replacement m              3 4                              4 Nuts (Cover flange)       Union                            NA        SA 194          NA      Replaced 1  1/4 Rune-28 Pum                                          Gr 6 Nu'ts (Cover ffeoge)     Nova            Heat No                ASME SA 194        NA    Replacement      N, 1 1/4"4unw28 8      1 Nuts(Valve cover)         Union              NA                    SA 194                    Replaced 1  1/4 4unc-28                                                      Gr u
Nuts ((Valve cover)       Nova            Heat No        NA    ASME SA 194        NA    Replacement 1 1/4 4unc-28 871201                      Gr 6
: 7.     Description of Work: Replaced stuffing box due to leakage and nuts due to galling.
: 8. Tests Conducted:       Hydrostatic Other: VT I
                                              ~      Pneumatic VT 2 X      VT 3            ~
Nominal Operating Pressure (ISLT) X pstg  Test  Temp.~'F
 
PSL2, NIS2 TRACKING NO. S L 9 - ~01 9 FORM      NIS-2 (Back)                                  Sheet 2 of 2
: 9. Remarks:      A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
1 0. Inspection Report Numbers:        MM95-584 APPLIGABLE MANUPAGTURE's DATA REPORTs  To BE ATTAGHEO Certificate          of Compliance Wa certify that the statements made in the report are correct and this                  Repair QRepiacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:      N/A Signed      8      I o
rg wner's Designee, Title
                                                  ~  or -  ZKT'r Date  ~VI      ito . f9~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                71            m&#xb9; inspector's  gnature                                    National Board, State, Providence and fndorsements Date
 
PSL-2, NIS-2 TRACKING NO.              SL-2C-      ~020 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.              Date:      2/6/96 P.O. Box 529100                        Sheet:      1  of Miam, FL 33152 Unit:      2
: 2. Plant:                        St. Lucio Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM &#xb9;: 386-288D
: 3. Work Performed By:            Florida Power  4 Light Co.              PWO&#xb9;: 0775 6501 South Hwy. A1A WO &#xb9;:      94010958 JcnsenBcach, FL 34957 CWO &#xb9;:      NA        Process Sheet:  N/A
: 4. (a) Identification of System:    Chemical & Volume Control Type Code Symbol Stamp    N/A CHPP 2C Authorization No.        N/A (b) Component                                                                                              N/A Identification:                                                                  Expiration Date (Mark Number)
(c) Code Class:      2 a) Applicable Construction Code and Addenda:      ASME SEC. III 71 ED-72 ADDENDA            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of        Manufacturer    National      Other          Year    Replaced      ASME Component        Manufacturer      Serial or Heat  Board                        Built    Repaired      Code or                                  No.        No. Identification                    or      Stamped Material                                                                                Replacement (Yor N)
SUCTION SPOOL        UNION PUMP                          NA      SA564 GR630          NA    Replacement PIECE CAP SCREW
: 7. Description of Work:    REPLACE CAP SCREWS WHICH WERE REMOVED DURING MAINTENANCEOF PUMP.
: 6. Tests Conducted:    Hydrostatic Other: VT1
                                                ~      Pneumatic VT2 X        VT3              ~
Nominal Operating Pressure (ISLT) psig  Test Temp.
X
                                                                                                                        'F
 
PSL-2, NIS-2 TRACKING NO.                  SL-2C-        ~020 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remai'ks:        A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:              MM95-1919 APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACNED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                                                    Ca~eQk 6              <0~G er o      ei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
C By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
g1g4 Commissions              NB7719      FL Com      &#xb9; 6889')
Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO. S L                8-    ~02 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.                Date:  07/12/95 P.O. Box 529100                          SheeL    1 of Miami, FL 33152 Unit:    2
: 2. Plant:                      St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach,  FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.                PWO&#xb9;: 7756 6501 South Hwy. A1A WO &#xb9;:    93020470 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet:        N/A
: 4. (a) Identificationof System:    Chemical & Volume Control Type Code Symbol Stamp          N/A V2326                                            Authorization No.                N/A (b) Component Identification:
(Mark Number)                                                          Expiration Date                  N/A (c) Code Class:    2
: 5. (a) Applicable Construction Code and Addenda: ASME SECT. III 74 EDrnON /No ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized. for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of      Manufacturer      National      Other        Year      Replaced          ASME Code Component or      Manufacturer      Serial or Heat      Board    Identification    Built      Repaired          Stamped Material                                No.            No.                                                  (Y or N)
                                                                                                      'I'eplacement Disc Insert      Crosby Valve            S/N            NA    Haynes Stelllte    NA        Replaced 1 1/2" X2"                        N91102-51-0080                  Alloy 68 Disc Insert      Crosby Valve            S/N                    Haynes Stelllte  1987    Replacement 1 1/2" X2"                        N911 02-99-0065                Alloy 68 Nozzle        Crosby Valve            S/N            NA      ASME SA 479      NA        Replaced 1 1/2" X2"                        N 91469-34-0013                Type 316 Nozzle        Crosby Valve            S/N            NA      ASME SA 479      1988    Replacement 1 1/2" X2"                        N91469-36-0015                  Type 316
: 7. Description of Work: Rebuild valve SN N59200-00-0005.
Replaced disc and Nozzle Valve to be used as spare.
: 8. Tests Conducted:        Hydrostatic Other: VT I
                                              ~  VT 2 Pneumatic VT 3 Nominal Operating Pressure (ISLT)
                                                                                  ~psig        Test  Temp.~'2
 
PSL-2, NIS-2 TRACKING NO. S              L-2    ~021 FORM      NIS-2 (Back)                              Sheet 2 of 2
: 9. Remarks:        None
: 10. Inspection Report Numbers:        NA APPLICABLE MANUFACTUAESDATA AEPOItTS TO BE ATTACHEO Certificate      of Compliance We certify that the statements made in the report are correct and this              Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp:          N/A Certificate of Authorization No.:
Signed 0  ner o N/A mfa'- ZVPV, LGi, wner's Designee, Title Date      h  I,      19 95 CERTIFICATE OF INSERVICE INSPECTION I,  the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                      F        &#xb9;60 tnspec or's Sig ature                                  National Board, State, Providence and Endorsements Date                                  19~5
 
PSL-1, NIS-2 TRACKING NO.              SL-2        022 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                Date:    11/25/95 P.O. Box 529100                          Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:      NA Jensen Beach,  FL 34957                PCM&#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.                PWO&#xb9;: 2160 6501 South Hwy. A1A WO &#xb9;:      94030738 Jensen Beach, FL 34957 CWO &#xb9;:      NA        Process Sheet:  N/A
: 4. (a) Identification  of System:      Intake Cooling Water Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                    SB 21251 Identification:                                                                    Expiration Date          N/A (Mark Number)
(c) Code Class:    3 a) Applicable Construction Code and Addenda:        ASME Section III, 1971 edition, no ad. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other          Year      Replaced        ASME Component        Manufacturer        Serial or Heat  Board                        Built    Repaired        Code or                                    No.        No. Identification                    or        Stamped Material                                                                                  Replacement (Yor N)
STEEL PLATE    BETHLEHEM STEE            RIR &#xb9;        NA      ASME SA 51 5 G              Replacement 3/8 X48 X96                                2FC318                        70 FW 2000              FPL            WELD TRAVL&#xb9;      NA            &#xb9; LINE CW-20        NA      NEW WELD BUTT WELD                                95-2712 FW 2000              FPL            WELD TRAV&#xb9;        NA      LINE  &#xb9; CW-21      NA      NEW WELD BUTT WELD                                95-2713
: 7. Description of Work:      REMOVE VALVES AND CAP OFF PIPING WITH PLATE. MATERIAL. NEW WELD ADDED.
: 8. Tests Conducted:      Hydrostatic Other. VT1
                                                  ~      Pneumatic VT2 X        VT3              ~pstg        TestTemp.    ~'F Nominal Operating Pressure (tgLT)
 
PSL-2, NIS-2 TRACKING NO.                      SL-2    ~022 FORM NIS-2 (Back)                                            Sheet 2 of 2
: 9. Remarks:        go<<i        VG    L<+<~
I
: 10. Inspection Report Numbers:      2-Z PT- Q l APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair        X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                      I I                                          Date Ioae 29 Owner'wner's      Designee, Title 19'ERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVs Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL Com          &#xb9;60 Inspector's Signature                                      National Board, State, Providence and Endorsements Date                    /f,          19~
 
7'of 9 TECHNICAL DEPARTMENT PROCEDURE NO. 2-IPT-32, REVISI ST. LUCIE UNIT 2                    'B'agy HYDROSTATIC PRESSURE TEST ICW LOOP TEST DATA SHEET TEST DES CRIP77ON                                                            SYS      ESC I Q SYSTEM LEAKAGE TEST                                                'B'NTAKE COOLING WATER PUMP DISC Q SYSTEM FUNCTIONALTEST Q SYSTEM LNSERV(CE TEST                                              SYSTEM CODE CLASS: Q 1(A)                  ~  3(C)
~ SYSTEM HYDROSTATIC TEST                                            SYSTEM DESIGN PRESSURE:                90            PSIG Q SYSTEM PNEUMATIC TEST                                              SYSTEM OP. PRESSURE:                    60            PSIG Q INSTRUMENTED INSPECTION (IIT)                                      SYSTEM DESIGN TEMP:                    125            oF DRAWING(S)'2(B)90 SYSTEM OP. TEMP.:                                    'F QSCHEDULED          QUNSCHEDULED'EPAIR REFERENCE                    2998-&482 Current        Revision Q                  REPLACEMENTS'REVIEW by ISI REQUIRED TEST CONDmONS                                                            TEST CONDmON HOLD TIME TEST MEDIUM:          SEA WATER                                              INSULATED                      N 0 NIN SU IATED    'I WATER CHEMISTRY: NOMINALICW                                          Q 0-MIN (SYS LEAKAGE)            0 MIN (SYS LEAKAGE)
PLANT SOURCE: Screen Wash Pumps                                      Q 10-M(N (FUNCTIONAL)        , Q 10-MIN (FUNCTIONAL)
Q 10-MIN (PNEUMATIC)            Q 10-MIN (PNEUMATIC)
TEST TEMP:            AMBIENT                                  '.F Q 4-HOUR {HYDRO)                ~ 10-MIN {HYDRO)
                                                              'F    Q 4-HOUR (INSERVICE)              10 MIN (INSERVICE)
EXAM. TEMP:          AMBIENT ANII WETNESS                                                    TEST TIMETABLE                  77ME        DATE
~
Q REQUIRED ANII
      ~Sea. coal DATK WAIVED                        ACHIEVED TEST CONDITIONS ACHIEVED REQUIRED HOLD TiME COMPLETED VT-2 EXAMINATION I  190 I(-id<
1 -2.g+
TEST RESULTS
 
==SUMMARY==
MEASURING & TEST EQUIP.            IDENT.
Z. 30Z.                                              le~        MASTER GAUGE    ~
II-~3qS BACKUP GAUGE                                      /j->>.
EXAMJTEST PERSONNEL            METHOD          LEVEL V7 2-a GATE.~Z"I DISCREPANCIES                                                                FINAL TEST REVIEW Q STAR                                                                TEST SUPV.                        ATE:      -?
Q NPWO                                                                AN!I:                          DATE:
0 OTHER
 
/                                                        ST. LUCIE UNIT 2 TECHNICAL DEPARTMENT PROCEDURE NO. 2-IPT-31, REVISION Page 7 of 10 PRESSURE TEST ICMI LOOP A AND C                                3"'-'YDROSTATIC TEST DATA SHEET System
 
== Description:==
 
Q    System Leakage Test                                    Intake Coolin Water Pum          Disch Q    System Functional Test                                                    AB C Q    System Inservice Test                        System Code Class Q        1  (A) Q 2 (B)
General Test 8    System Hydrostatic Test                      System Design Pressure            -        90                          PSIG Data      Q System Pneumatic Test                            System Op. Pressure                        60                          PSIG Q Instrumented lns ection                      I  System Design Temp:                        125                            'F Q Scheduled Q      unscheduled'g System Op. Temp:                            90$ 5                          dF Repair'          Replacements'ISI Reference Drawing(s) 29986-082 Coordinator Review                                          Current Revision T  Conditions                                          Test    ondition Hold Time Test medium:      Sea Water                                  Ins la                          N nin                I Water Chemistry: Nominal ICW                      Q  0-min {Sys Leakage)              Q 0-min (sys Leakage)
Test      Plant Source: Screen Wash Pum s                  Q  10-min {Functional)              Q 10.min (Functional)
Parameters                                                      Q  10-min {Pneumatic)                Q 10-min {Pneumatic)
Test Temperature: Ambient                      'F Q  2-hour (IIT)                      0 10-min (Hydro)
Q  4-hour (Hydro)                    Q 10-min (lnservice)
Exam. Tem .:    Ambient                      'F  Q  4-hour lnservice                  Q10-min I ANII Witne s                                  Test Timetabl Z    mme                      D te O Rgerered    MWei~ed                            Achieved Tes      n  'i  n ANII                                Date  tr-i  A hi vedRe ui          oldTime I    VT-    x    i    i n      22,  <<                    I{
T t Resul s Summa                            Me      'n    Te      ui            Id nt                        I Da e
                                                                                                            -ZS                IO-Sl-9 Test sAza~s        I~                                    cku    au                              -Z                      0-Sl Implementation SBZ{Z.<l          A                        trgz.S Exam JTest Pere nnel                    Method                      L vel lR<s  T~< AeemcbPfFS                      RYbPe                                        U<~
              ~Lu~~g        oo t4P<O                    2-/f,o Di re an ie                                                  ~nal  Te t    eview Post      Ef~                                              Test Eng~..                                Date:/            -/l 85 Test      C6WO        a            SOI              %~0    ISI Coor .:                                Date:    II Q Other                                          ANII'.                                      Date:~6~
 
PSL-2, NIS-2 TRACKING NO.              SL-2            ~023 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.'wner:                          Florida Power & Light Co.                Date:      1/22/96 P.O. Box 529100                          Sheet:      1 of  2 Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hvvy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:            Florida Povver & Light Co.              PWO&#xb9;: 4812 6501 South Hwy. A1A WO &#xb9;:      95023706 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:        N/A
: 4. (a) IdenQication    of System      Chemical & Volume Control Type Code Symbol Stamp            N/A CHG PP 2B                                          Authorization No.              N/A (b) Component Identification:                                                                      Expiration Date .                N/A (Mark Number)
(c) Code Class:          2 (a) Applicable Construction Code and Addenda: ASME SEC. III; 1971 ED.;W72 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National        Other          Year      Replaced            ASME Component          Manufacturer        Serial or Heat  Board                          Built    Repaired            Code of                                    No.        No.      Identification                                  Stamped oi'eplacement Material (Yor N)
FLUID BLACK          UNION PUMP        N52918-N S/N 2      NA      SA182 TYPE 304      1976      Replaced ASSEMBLY FLUID BLACK          UNION PUMP        N52918-N S/N 2      NA    SA182 TYPE 304      1988      Replacement ASSEMBLY
: 7. Description of Work:      REPLACE FLUID BLOCK DUE TO CRACKING.
: 8. Tests Conducted:      Hydrostatic Other. VT1
                                                  ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure (ISLT)
                                                                                    ~psig          TestTemp.
X
                                                                                                                                'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2        ~023 FORM NIS-2 (Back)                                      Sheet 2 of 2
: 9. Remarks:        A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:              Wg Q APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A sISne8        t    4            A sR        (88>T  5IPU    -  Isi      Date          ~2., 19~~
er or 0    r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions            NB7719 FL      Com&#xb9;60 inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-I, NIS-2 TRACKING NO.              SL-2      ~824 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                      As Required by the Provisions of the ASME Code Section XI
: l. Owner:                          Florida Power & Light Co.                Date:      12/13/95 P.O. Box 529100                          Sheet:
Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucic Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power  & Light Co.              PWO&#xb9;: 4058 6501 South Hwy. A1A WO &#xb9;:      95012105 Jensen Beach, FL 34957 CWO &#xb9;:      NA        Process Sheet:  N/A
: 4. (a) Identification of System:          Safety Injection Type Code Symbol Stamp    N/A V3414 Authorization No.        N/A (b) Component                                                                                                    N/A Identification:                                                                        Expiration Date (Mark Number)
(c) Code Class:            2 a) Applicable Construction Code and Addenda:                              NA                        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification        of Components Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer    National        Other        Year      Replaced      ASME Component              Manufacturer      Serial or Heat  Board                        Built    Repaired      Code No.        No. Identification                    or      Stamped oi'aterial                                                                              Replacement (Yor N)
Seal Weld                  NA                Ht No                    ER 316                  Replacement (FW 2003)                                GT 6100 0434                (P8 to P8)
: 7. Description of Work:        Remove and replace seal weld to facilitate valve work.
: 8. Tests Conducted:          Hydrostatic Other:  VTI
                                                      ~      Pneumatic VT2 X        VT3 Nominai Operating Pressure (ISLTI
                                                                                        ~Psig          TestTemP.
X
                                                                                                                              'F
 
PSL-2, NIS-2 TRACKING NO.                    SL-24I-        ~024 FORM NIS-2 (Back)                                          Sheet 2 of 2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:            MM95-2352 APPUCABLE MANUFACTURE'S DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed vmer Auuk, vmeVs Designee, Title o t/. lS(            CaIe  ~l.,            IS~5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this OwneVs Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719      FL Com      &#xb9;60 I spector's Signature                                      National Board, State, Providence and Endorsements Date                                , 19~%
 
PSL-1, NIS-2 TRACKING NO.              SL-2      025 FORM NIS-2 OWNERt S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power  k Light Co.              Date:      11/22/95 P.O. Box 529100                          Sheet:    1  of  2 Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power  k Light Co.              PWO    &#xb9;:  2821 6501 South Hwy. A1A WO &#xb9;:      95007333 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification  of System:    Safety Injection Type Code Symbol Stamp    N/A V3551 Authorization No.        N/A (b) Component Identification:                                                                    Expiration Date          N/A (Mark Number)
(c)  Code  Class:    2 (a) Applicable Construction Code and Addenda:                          NA                        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer    National      Other          Year    Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code of                                      No.        No. Identification                  or        Stamped Material                                                                                    Replacement (Yor N)
SEAL WELD                FPL        WELD TRAVELO        NA      SA-182 316 SS              Replacement FW-2002                                &#xb9; 95-2473
: 7. Description of Work:      Remove and replace seal weld to facilitate valve work.
: 8. Tests Conducted:      Hydrostatic Other: VT1
                                                  ~      Pneumatic VT2 X        VT3              ~pstg        TestTemp.    ~'P Nominal Operating Pressure (ISLT)      X
 
PSL-2, NIS-2 TRACKING NO.                SL-2        ~025 FORM NIS-2 (Back)                                      Sheet 2 of 2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:          fA K t 5 - Q~ ~        I APPUCABLE MANUFACTURES DATA REPDRTB To BE ATrACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                              'cCC er's Designee, Title Pu  lhl        Date  ~0t/~ 19~
Ow er or CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the OwneVs Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719      FL  Com&#xb9;60 Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NtS-2 TRACKING NO.              SL-2C-      ~026 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                          As Required by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power  4 Light Co.              Date:      11/14/95 P.O. Box 529100                        Slleet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:      NA JensenBeach,  FL 34957                PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power  k Light Co.              PWO&#xb9;: 2418 6501 South Hwy. AlA WO &#xb9;.      95001976 Jensen Beach,  FL 34957                                      s CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification  of System:    Safety InJection Type Code Symbol Stamp      N/A HCV-3616                                        Authorization No.          N/A (b) Component Identification:                                                                    Expiration Date            N/A (Mark Number)
(c)  Code  Class:    2 (a) Applicable Construction Code and Addenda:                          NA                        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer    National        Other        Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built      Repaired      Code or                                      No.        No. Identification                    of        Stamped Material                                                                                    Replacement (Yor N)
Seal Weld                NA                Ht No        NA        P8To P8            NA      Replacement DT 6289                    ER 316
: 7. Description of Work:      Remove seal weld for valve inspection and reweld following examination.
: 8. Tests Conducted:        Hydrostatic Other: VT1
                                                  ~      Pneumatic VT2 X      VT3 Nominal Operating Pressure (ISLT)
                                                                                    ~psig          Test Temp.    ~'F  X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~026 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        PA)RQ G -Q, K5+
APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Owner r AR ei's Designee, Title Date  ~AV I            19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this OwneVs Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVS Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
8v inspectors S!gnature Commissions              NB7719 FL Com          &#xb9;60 National Board, State, Providence and Endorsements Date        /                        19  <6
 
0 PSL-1, NIS-2 TRACKING NO.              SL-2      027 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power & Light Co.              Date:      11/14/95 P.O. Box 529100                          Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. AlA                      P.O.&#xb9;:    NA JcnscnBeach, FL 34957                    PCM&#xb9;: NA
'. Work    Performed By:          Florida Power & Light Co.                PWO    &#xb9;:  2863 6501 South Hwy. A1A WO &#xb9;:      95009205 Jensen Beach,  FL 34957 CWO &#xb9;:      NA        Process Sheet:  N/A
: 4. (a) IdenQication      of System:    Safety Injection Type Code Symbol Stamp    N/A V3523 Authorization No.        N/A (b) Component Identification:                                                                    Expiration Date          N/A (Mark Number)
(c) Code Class:      2 a) Applicable Construction Code and Addenda:                            NA                      Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. IdentiTication    of Components Repaired or Replaced and    Replacement Components:
Type of              Name of        Manufacturer    National        Other        Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                      No.        No. Identification                  or        Stamped Material                                                                                    Replacement (Yor N)
Seal Weld                NA          Ht No DT6289      NA        P8To P8          NA      Replaced ER 316 Filler              (SA-182 FQ16)              Seal Weld
: 7. Description of Work:      Remove seal weld for valve inspection and reweld following examination.
: 8. Tests Conducted:        Hydrostatic Other. VT1
                                                  ~      Pneumatic VT2 X      VT3 Nominal Operating Pressure (ISLT)
                                                                                      ~psig        Test Temp.
X
                                                                                                                          'F
 
PSL-2, NiS-2TRACKtNG NO.                  SL-2        ~927 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:          'g INQ Q Q,RES APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTADHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed    I    A          a    K PLtttttr R%/-                          Date  ~CI/ t5          19~7 Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL        Com&#xb9;60 Inspector's Signature                                    National Board, State, Providence and Endorscments Date
 
PSL-I, NIS-2 TRACKING NO.                SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS EP                          As Rcquircd by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power & Light Co.                  Date:    11/29/95 P.O. Box 529100                            Sheet:    1  of 2 Miami, FL 33152 Unit:
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.lf:  NA Jensen Beach, FL 34957                      PCM/I: NA 3, Work Performed By                Florida Power & Light Co.                  PWO//: 8726 6501 South Hwy. AIA WO f/:    94007112 Jensen Beach, FL 34957 CWO f/: NA          Process Sheet:            N/A
: 4. (a) Identification    of System:      Main Steam Type Code Symbol Stamp              N/A MV-08-1 B Authorization No.                  N/A (b) Component Identification:
Expiration Date                    N/A (Mark Number)
(c)  Code  Class:    2 a) Applicable Construction Code and Addenda:                ASME Sect III 1974 Ed/S 74Add.          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer      National      Other        Year          Replaced            ASME Component            Manufacturer          Serial or Heat    Board                        Built        Repaired            Code Of                                          No.        No. Identification                                      Stamped OI'eplacement Material (Yor N) isc tern                o    e                eat o                                                    ep ace Assembly                                      H2261                      TP 316 Disc    tern            o    e              ena    o                      4          963          ep acement Assembly                                      H6572                    TP 316
: 7. Description of Work:        Replaced stem/disc assembly, oui"      +'~~          ~'+~Qc
                                            - requires seal weld replacement. Tracked on PWO 95013022  'ote NIS No. SL-2-8-039
: 8. Tests Conducted:          Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                    psig  Test Temp.                      'F
 
PSL-2, NIS-2 TRACKING NO.              ~
SL-2                                                    FORM NIS-2 (Back)                                        Sheet 2 of      2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:          (5% $    5- g,~    I@
APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                              +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                          <Q. P~,
ner's Designee, Title Date~L'~,            19~
wner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
1 By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions inspector's Signature                                        National Board, State, Providence and Endorsements Date                                , 19~~.
 
PSL-1, NIS-2 TRACKING NO.            SL-2                                                  FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                          Florida Power    & Light Co.              Date:      11/29/95 P.O. Box 529100                            Sheet:      1  of  3 Miami, FL 33152 Unit:
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.//:    NA Jensen Beach, FL 34957                      PCM f/: 009-293M
: 3. Work Performed        By'lorida Power                Ec Light Co.              PWO f/:
6501 South Hwy. AIA WO f/:      94005831 Jensen Beach, FL 34957 CWO f/:              Process Sheet:  N/A
: 4. (a) Identification    of System:        Service Air Type Code Symbol Stamp      N/A V1 81270 Authorization No.        N/A (b) Component Identification:                        (service air)                                      Expiration Date          N/A (Mark Number)
(c) Code Class:      2 (a) Applicable Construction Code and Addenda:                ASME Sect III 1986 Edition No Add          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components      Repaired or Replaced and Replacement Components:
Type of              Name of              Manufacturer      National      Other        Year      Replaced      ASME Component          Manufacturer            Serial or Heat    Board                        Built    Repaired        Code or                                          No.          No. Identification                  or        Stamped Material                                                                                          Replacement (Yor N) a e                  0    e                                                                      ep ace 2 Check a e              n    or a mg                                            10                  ep acement 2 Check Ipe 2                      aw                                              06                    ep ace Sch 40                                                                    GrB pe 2          icago    u e    ron                                      106                  ep acemen Sch 40                                      2J122                        GrB 200 so et              e    rave er                                        i er                  ep acement (Old weld No FW 14)            95-2739                                        ER7082 2      so et          e    rave er          06                            i er                  ep acement (Old weld No FW13)              95-2740                                        ER7082
: 7. Description of Work:            Replaced valve due to leakage. replace by welding. Includes replacement of section of piping.
(This valve is a CIVI penis)
: 8. Tests Conducted:            Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2~          VT3                      psig  Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.              SL-2                                                    FORM NIS-2 (Back)                                      Sheet 2 of      3
: 9. Remarks:          A satisfactory pneumatic test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:
APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed er or    ner's Designee, Title i  Kopv              Date  ~Cl, IS~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-I, NIS-2 TRACKING NO.          SL                                    FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of thc ASME Code Section XI PL                                SUPPLEMENTAL SHEET
: 1. Owner:                Florida Power 0 Light Co.                Date:        4f22I94 P.O. Box 529100 Miami, FL 33152                    Sheet:            3 of    3
: 2. Plant:                St. Lucie Plant                  Unit &#xb9;:
6501 South Hwy. A1A Jensen Beach, FL 34957              P.O. &#xb9;:            NA
: 3. Work Performed By: Florida Power & Light Co.                'PCM  &#xb9;:        009-293M 6501 South Hwy. AIA
: 6. Identification of Components  Repaired or Replaced and Replacement Components:
National                            Replaced          ASME Name of          Name of          Manufacturer                    Other          Year Board                              Repaired          Code Component          Manufacturer      Serial or Heat                Identification  Built No.        No.                                                  Stamped OI'eplacement (Y or N) so e        e    rave er                                    e    rave er          ep acemen (Old weld No FW 12)      95-2741                                          95-2740
 
FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR VALVESe AI RequIgod by tne f)rovtahf)I of the ASME Code, Se0tIon III, DlvIalon 1
                                                                                                                                'Pg.            of Manufactured snd certified by            Anchor/Darl i ng          Va 1 ve Co      .,  70 1 Fi rst St        .,    Wi 1  1 i amspor      t,  PA 1770 (nano end address of N Cart(()cata Ho(dar)
M      f ctu sd f        F1  ori da    Power    8    Li ht      Com  an,        P. 0. 8ox 029950, Ni ami, FL                          33102-9950 (nsms and address of Purchaser or Owner) 3, Location of Installation
: 4. Model No., Series No., or Type                      Gb          ore~
(nemo and address)
W9323936                R  .        A                cjjN=
ted)don)              (addenda date)                (dass)                (Coda Case no.)
II                                        2n Nominal Inlet s(a                2 B. Pump or valve (In.)
7 Mater(a).        Body SA216-WCB                Bonnet                                  0    6  -600-10          Ij lal                            lbl                          Icl                            ldl                              Iel cen.                            Nat'I                        Body                          Bonnet                            Olsk Ho(der'a                          Board                        Serial                        Serial                            Serial Ser(al No.                          No.                          No.                          No.                              No.
E-T488          1                          N/                                                                              T  C  A761A E-T 88-5-2                                    N  A                                            HT.&#xb9;C0607                      T      A 61A
'Suoo(ements( lnfonnsoon in form of ((ets, sketches. or drawings may be used provided l1) e(ae ls 8)5'          11, (2l infonnaoon in (terna 1 through 4 on this Oats iteoort is included on each sheet, (3) each sheet is numbered snd the number of sheets is recorded at the too of the form.
('I 2/88)                        this form (8)0037) msy be obtained from the Order Oeot.. ASM8. 22 Law Or(vs. Box 2300. Febfleld, NJ 07007 2300.
isk          '-        +g-2.Q- 0 Q.Q iR f~ at~
                                                                                                              ~ W page
 
ST. LUCI          IT 2                          ts OPERATItla PROCEDURE NO. 2-1300051, REVISION $ 3 LOCAL LEAK RATE TEST DATA SHEET 4 Test Procedure                                        Penetration No:
Note: Make a list of          ail caps        and  flanges that are removed, ln the Remarks                                    Stat)on Alr {Pg. 1 of 2)
Section below.                                                                                        Type Test:              Bypass 5, Qt osa sglgl2.$ 'I                        H)get o                                                Test Pressure:          41.8 (+1.1, %) psig
: 1. Close V-18-1253,+~%-, SH-18-797.                                                                  Test Media:              Air or N,
: 2. Open V-18-784 and V-18-1271 (Vent Path). he> SH- IS- f254.
Test Locat)on:          23'ontainment
: 3. Pressurize against 2-IY-18-1270 through SH-18-1254.                                                                        1" female adapter
: 4. Measure and record leakage.                                                                        Test Fittings Required; lose V-18-784 and t-HCV-18-2.
S10pen SH-18-1252 (Vent Path).
X$ Pressurize against l-HCV-18-2 through V-18-1271.
g') Measure and record leakage.
Sl>Close SH-18-1252.                                                                                            Valve No.        2-lv-18-1270        I-HCV-18-2 16:llOpen V-18-784 (See page 2 of 2).
Gauge Serial No.
a..Two go.~e~            ~sWtt,        to,~ca >~ I V't.o    a{ fsoues-Qsyr L~ r Tv r C'~~v'~ r =c>(o ~ m~4.
JS                                                                                        %AT fa~p Q
          <<~4~04          ~R f5',eg~Sa~++C eel.eve ~+ t l~ p~s(+O,-g a~                                                          Rotameter Serial No.                          T6--/5
          > ~wWQecl est K~V raS'r CArRW ~~~ Po~                                                        Rotameter Range 5QC~                          \  5 /sZS lg.Q., fs) struts y ANll O'C,LAcu+ N p &r@sst,gg~
l'ts /s &ehgallt) sm<Peaes~ /&+Sat,rt                        ~            f  pSt,
                                                                      /Q5 pygmy (yg~)
Date Time Start
                                                                                                                                        -z/-p
            )t'o  +e    6'+  4                                                                      Time End                                          S /O o
Ai4~ HoQ'~ ~~+P~S~Se    usda'<a.
                                                                ~4aLle W          Jf $(fS~)P5    g    Pressure Start
          $'Or    lO  artois gsa4qsa          p6 +arm 'tr/T2      O C    ttff1jff~7  g ~Q .          Pressure End o4-8~ 5cwpmgckp as xeekpP lych"reaa&DC~                  Le mai<4;s~
                                                            )                        ~              Leakage (SCCM)
          ~eP~~~~>t>e.+n+ bau.<da.~ +L P~ +es+cm+ v&9,
  )S.S    P-o(.eeJ +~            s~~,            ~                                                  Leakage Limit (SCCM)
Verified By 8,000              8,000 RoasonForTest:
Remarks; G18MonthSorveittanoe le>>
0 ril -R Vi F-0-
seau tv..~Q 6 PreMaint    gP      stMaint CI Other
                                                                                  ~m~ /-~'I      PS
                                                                                                      -2.I V T~/Z  r//z/<$
                                                    ~CCruLC<4Iree          Ptr CSbsa sC AC&
Sntattraa...oAs                os. APrJso          Sto2.t(t,i
 
PSL-2, NIS-2 TRACKING NO. S L 8 -                31 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of thc ASME Code Section XI
: 1. Owner                                Florida Power & Light Co.                        Date: 12/19/95 P. O. Box 529100                              Sheet:  1          of  5 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. AIA                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO    &#xb9;: 8507
: 3. Work Performed By:                  Florida Power & Light Co.                      WO &#xb9;: 95026315-01 6501 South Hwy. AIA                            WCD &#xb9;: 0244 Jensen Beach, FL 34957
: 4. (a) Identification of System        2A a 2B DIEsEL oIL TRANsFER LINEs          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        1-2"-DO-62  & 1-2"-DO-63                              Expiration Date N/A (Mark Number)
(c) Code Class:            3
: 5. (a) Applicable Construction Code and Addenda:          ASME 1974 S 1974 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year      Replaced      ASME Code Component or        Manufacturer Serial or Heat        Board      Identification Built Repaired or        Stamped Material                              No.          No.                                Replacement      (Y or N)
PIPE - 2" SA106GR. B              NIA              NIA            N/A            NIA          N/A    REPLACED          NO PIPE - 2"        TIOGA PIPE      HT.&#xb9; 637224                  UTC 379890 SA 106 GR. B          SUPPLY          & N68491        N/A          RIR 29032      1995  REPLACEMENT          NO PIPE -3"        TIOGA PIPE        HEAT  &#xb9;                  UTC 381359 SA 106 GR. B          SUPPLY          N 68491                  RIR 2J-1100      1994 MODIFICATION          NO
: 7. DESCRIPTION OF WORK:                  LEAKAGE OF 13 GAL. PER DAY IDENTIFIED IN ORIGINAL LINE. REPLACEMENT WITH MODIFICATIONTO PROVIDE IMPROVED CORROSION PROTECTION.
: 8. Test Conducted:          Hydrostatic [ X]              Pneumatic    [X ]                Nominal Operating Pressure (ISLT) [ X]
Other: VT 1 [ ]          VT 2 [X ]        VT 3 f ]          HYDRo-150 PSIG        Test Temp. 1HR. @ sYs. F IsLT-110 PSIG      Test Temp. 10 MIN.e sYs. F
 
PSL-1, NIS-2TRACKING NO. S            L-2          31 FORM NIS-2            (Back)                  Sheet    2    of
: 9. Remarks            HYDRosTATIG TEsTs AND IsLTwERE sUGGEssFULLY PERFoRMED AND WITNESSED BY CERTIFIED Q.C. INSPECTORS.
: 10. Inspection Report Numbers:            ISLT - M95438 HYDRO'S- M95-157, M95-196, M95-197, M95-377, M95-388, 8 M95-389 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this          [  ] Repair  [ X ] Replacement  /
f ] Modification conforms to the rules of the Asme Code, Section XI.
X Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date  QeC.        k  l,    19  15 Owners orOwner's DB gnee, TI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date                                                    19~<'
 
PSL-2, NIS-2TRACKING NO. S              L-2        31 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section      XI
: 1. Owner                            Florida Power & Light Co.                          Date: 12/19/95 P. O. Box 529100                                Sheet:  3          of 5 Miami, FL 33152                                    Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                          P.O. &#xb9;: N/A 6501 South Hwy. A1A                              PCM &#xb9;: 096-295 Jensen Beach,  FL 34957
: 3. Work Performed By:                Florida Power  & Light Co.,  6501  SAlA Hwy., Jensen Bch., FL 34957
: 4. Identification  of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National          Other          Year    Replaced    ASME Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or          Stamped Material                          No.            No.                                Replacement      (Yor N)
FLANGE - 2" SA 105            NIA              N/A          NIA            NIA            NIA    Replaced FLANGE-2"        TIOGA PIPE        HEAT  &#xb9;                    UTC  377921'IR SA 105          SUPPLY          8866369          NIA                27412      1995  Replacement ELBOW -2" SA 105 90 DEG.        N/A                            NIA            NIA            NIA    Replaced HT.&#xb9; R143S, ELBOW-2"        TIOGA PIPE        8867888,                    RIR&#xb9; 29401, SA 105 90 DEG.      SUPPLY          8869827          N/A          2K~46          1995  Replacement ELBOW -1 1/2" SA 105 90 DEG.        N/A              N/A          N/A            N/A            NIA    Replaced        NO ELBOW -1 1/2"    TIOGA PIPE        HEAT  &#xb9;                    UTC 340391 SA 105 90 DEG.      SUPPLY            R28C          N/A        RIR 2K-0195      1995  Replacement        NO ELBOW - 2" SA 105 45 DEG.        N/A              NIA          N/A            NIA            NIA    Replaced        NO ELBOW - 2" SA 105 45 DEG.      HUB, INC.            &#xb9; HEAT MC-81          NIA        UTC 378122        1988  Replacement UNION - 1 1/2" SA 105            N/A              NIA          NIA            N/A            N/A    Replaced        NO UNION - 1 1/2"    TIOGA PIPE    HEAT&#xb9; 26215                      UTC 34272 SA 105          SUPPLY        (NUT) 28332        N/A        RIR 2H-3441      1993  Replacement      NO COUPLING - 2" SA 105            N/A              NIA          NIA                            N/A    Replaced        NO COUPLING - 2"      TIOGA PIPE        HEAT  &#xb9;                    UTC 380213 SA 105          SUPPLY          M46010          N/A          RIR 29401        1995  Replacement      NO COUPLING - 2" SA 105            NIA              N/A          NIA            NIA            NIA    Replaced COUPLING - 2"      TIOGA PIPE      HT. CODE                      UTC 384011 SA 105          SUPPLY            008J          N/A          RIR 33042        1995  Replacement      NO
 
PSL-2, NIS-2 TRACKING NO. S L            8-      31 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section    XI
: 1. Owner                                Florida Power  & Light Co.                        Date: 12/19/95 P. O. Box 529100                                Sheet:  4          of 5 Miami, FL 33152                                  Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A I A                          PCM &#xb9;: 096-295 Jensen Beach,  FL 34957
: 3. Work Performed By:                  Florida Power  & Light Co.,  6501 SAI A Hwy., Jensen Bch., FL 34957
: 4. Identification    of Components  Repaired or Replaced and Replacement Components:
Type of            Name of      Manufacturer      National        Other        Year    Replaced    ASME Code Component or        Manufacturer Serial or Heat        Board      Identification Built Repaired or        Stamped Material                                            No.                                Replacement    (Yor N)
REDUCER - 1 1/2" SA 105              N/A              N/A            NIA                          N/A    Replaced        NO REDUCER - 1 1/2"        DUBOSE                                        UTC 372132 SA 105          NAT'L ENR.      HEAT &#xb9;009G        N/A        RIR 2D-7774      1995  Replacement        NO BAR,FlAT- A36        INTERSTATE                                      UTC 366048 1/4" X 8"          STEEL        HT.&#xb9; 227640        N/A        RIR R82-2191    1982  Replacement BAR,FLAT - A36                                                      UTC 378632 1/4" X 1/2"        HUB INC.      HT.&#xb9; G7511        NIA      RIR3AH-2235      1993  Replacement BAR,FLAT- A36        INTERSTATE                                      UTC 365966 3" X 1/2"          STEEL          HT.&#xb9; 16663        NIA        RIR R82-1515    1982  Replacement        NO BAR,FLAT - A36                                                      UTC 372171 4" X 1/2"      ENERGY STEEL        &#xb9; HT 642767          N/A        RIR 3AJ-1414    1994  Replacement BAR,FLAT- A36          DUBOSE                                        UTC 378748 12" X 1/2"        NAT'L ENR.      HT &#xb9; K34177        N/A        RIR 3AJ4666      1994  Replacement        NO BAR,FLAT - A36      INTERSTATE                                    UTC 365976-1 314" X 2 1/2"        STEEL              &#xb9; HEAT 25748          NIA        RIR 4R4258      1984  Replacement        NO ANGLE - A36          DUBOSE                                        UTC 372122 2" X2" X1/4"        NAT'L ENR.            &#xb9; HEAT J4710          NIA        RIR 3AK4606      1995  Replacement        NO ANGLE - A36                                                      'TC 372126 3" X3" X1/4"                              &#xb9; ENERGY STEEL HEAT 831674            NIA      RIR3AK4238B 1995        Replacement        NO RND BAR-A36          DUBOSE                                        UTC 377719 1/2" FOR U-BOLT        NAT'L ENR. HEAT&#xb9; 831674        NIA        RIR 3AJ-1 369    N/A  Replacement        NO U-BOLT A36          BERGEN          BP PART&#xb9;                      UTC 378467 2" PIPE SIZE        PATTERSON          6510-2"          N/A          RIR 27761      1995  Replacement        NO U-BOLT A36          BERGEN          BP PART  &#xb9;                    UTC 373880 2" PIPE SIZE        PATTERSON          6510-2"          NIA        RIR 3AF<708      1992  Replacement        NO BOLT, SA 193        ALLIED NUT                                      UTC 372563 5/8"-1 1UNC 2A        AND BOLT        HT.&#xb9; 86240        N/A        RIR 2H-1962      1993  Replacement        NO
 
PSL-2, NIS-2 TRACKING NO. S          L-2      31 FORM NIS-2 OWVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section    XI
: 1. Owner                            Florida Power  & Light Co.                      Date: 12/19/95 P. O. Box 529100                              Sheet:  5        of 5 Miami, FL 33152                                Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: 096-295 Jensen Beach,  FL 34957
: 3. Work Performed By:              Florida Power  & Light Co.,  6501  SAIA Hwy., Jensen Bch., FL 34957
: 4. Identification of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other        Year    Replaced    ASME Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or      Stamped Material                          No.            No.                              Replacement    (Yor N)
NUT, HEAVY HEX SA 194 GR. 7    ALLIEDNUT        HEAT  &#xb9;                    UTC 377946 1/2"-13 UNC 2B    AND BOLT        8865606          N/A        RIR 2J-0423    1994  Replacement      NO NUT, HEAVY HEX A 563 GR. A    ALLIEDNUT        HEAT  &#xb9;                    UTC 371763 3/8"-16 UNC 2B    AND BOLT          L04058          N/A        RIR 3AJ-1253    1994  Replacement      No NUT, HEAVY HEX SA 194 GR. 7    ALLIED NUT        HEAT  &#xb9;                    UTC 375497 5/8"-11 UNC 2B    AND BOLT          L63812          N/A          RIR 25731    1995  Replacement      NO NUT, HEAVY HEX SA 194 GR. 2H    ALLIEDNUT        HEAT  &#xb9;                    UTC 377897:
5/8"-11 UNC 2B    AND BOLT          151603          N/A          RIR 27358    1995  Replacement NUT, HEAVY HEX SA 194 GR. 2H    ALLIEDNUT        HEAT  &#xb9;                    UTC 372081 5/8"-11 UNC 2B    AND BOLT          151603          N/A          RIR 22763    1995  Replacement      NO
 
PSL-1, NIS-2 TRACKING NO.              SL-2<-      ~032 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.              Date:      12/4/95 P.O. Box 529100                        Sheet:      1 of    2 Miam, FL 33152 Unit:      2
: 2. Plant:                            St. Lucic Nuclear Plant 6501 South Hwy. AlA                    P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM &#xb9;: 009-293M
: 3. Work Performed By:                Florida Power & Light Co.              PWO&#xb9;: 3640 6501 South Hwy. A1A WO &#xb9;:      93017569 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification    of System:    Chemical & Volume Control Type Code Symbol Stamp    N/A V2169                                            Authorization No.        N/A (b) Component Identification:                                                                      Expiration Date          N/A (Mark Number)
(c)  Code  Class:    2 a) Applicable Construction Code and Addenda: ASME SEC.III;1971 ED.-'73 ADDENDUM Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. IdentiTication    of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer    National        Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                      No.        No. Identification                    or        Stamped Material                                                                                    Replacement (Yor N) 2'ISTON CHECK            ROCKWELL                            NA      SA 182 TP 316      1978      Replaced VALVE              EDWARD 2'ISTON CHECK        ANCHOR DARLING S/N: ET 401938          NA      SA 351; CF 8M      1993    Replacement VALVE CH 104 FW 600              FPL          WELD TRAV&#xb9;        NA      SOCKET WELD                  Replacement 95-2324                (VALVE-PIPE)
CH 104 FW 601              FPL          WELD TRAV&#xb9;        NA      SOCKET WELD          1995    Replacement 95-2325                (VALVE-PIPE)
: 7. Description of Work:      REPLACED VALVEAND ASSOCIATED WELDS CH-104-SW 14 &15 AS PART OF A MODIFICATIONTO CORRECT SEAT LEAKAGE PROBLEMS.
: 8. Tests Conducted:        Hydrostatic Other: VT1 X X      Pneumatic VT2 X      VT3 Nominal Operating Pressure (ISLT)
                                                                                      ~pstg          Test Temp.    ~'P
 
PSL-2, NIS-2TRACKING NO.                  SL-2        032 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:          NEW WELDS WERE EXAMINEDBY THE LIQUID PENETRANT METHOD BY CERTIFIED INSPECTORS. A HYDROSTATIC TEST OF THE NEW ASSEMBLY WAS PERFORMED. NO LEAKAGE EVIDENT.
: 10. Inspection Report Numbers:              OST HYDRO RPT&#xb9; 3640 APPLICABLE MANUFACTURES oATAREPORTSTO BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this                        Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                GP
* Date&~ 19~
r r        s Oasignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
dM Commissions                    NB7719 FL Com          &#xb9;60 spector's Signature                                        National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2TRACKING NO. S            L-2          33 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/13/95 P. O. Box 529100                              Sheet:    I          of  3 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. f/: N/A 6501 South Hwy. AIA                          PCM 0: 058-295 Jensen Beach, FL 34957                      NPWO 0: 8234
: 3. Work Performed By:                    Florida Power  & Light Co.                    WO &#xb9;: 95020553-01 6501 South  Hwy. AIA                          WCD &#xb9;: 0220 Jensen Beach,  FL 34957
: 4. (a) Identification of System          COMPONENT COOLING                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification          'A'UPPLY HD'R. 1-8"<C<7 TAG SB 14628                  Expiration Date N/A (Mark Number)              'A'ETURN HD'R. 1-8 "<C-50 TAG SB14629
                                          'B'UPPLY HD'R. 1-8'<C-53 TAG SB 14630 (c) Code Class:    3                  'B'ETURN HD'R 1-8"<C-54 TAG SB14631
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of        Manufacturer    National        Other      Year      Replaced      ASME Code Component or        Manufacturer Serial or Heat          Board      Identification Built Repaired or          Stamped Material                              No.            No.                                Replacement      (Y or N)
VALVE- 6"        HENRY PRATT          SERIAL&#xb9;                    UTC 380404            A'UPPLY HD'R SA 516 GR. 70          CO.            DD375-1-1        N/A          RIR 29783    1995        MOD.
VALVE- 6"        HENRY PRATT          SERIAL&#xb9;                    UTC 380406                A'RETURN SA 516 GR. 70          CO.            DD375-1-3        N/A          RIR 29783    1995      HD'R MOD.
VALVE- 6"        HENRY  PRAYI'O.
SERIAL&#xb9;                      UTC 380405            B'UPPLY HD'R SA 516 GR. 70                          DD375-1-2        N/A          RIR 29783    1995        MOD.
VALVE- 6"        HENRY PRATT          SERIAL&#xb9;                      UTC 380408              B'RETURN SA 516 GR. 70          CO.            DD375-1A          N/A          RIR 29783    1995      HD'R MOD.
: 7. DESCRIPTION OF WORK:                  PERMANENT MODIFICATIONTO SUPPLY A/C TO CONTAINMENTTO REDUCE MAN REM I MAN HOURS FOR CONTAINMENTJOBS.
: 8. Test Conducted:          Hydrostatic [X ]              Pneumatic    []                  Nominal Operating Pressure (ISLT) [ ]
Other. VT1 []            VT2[X]          VT3 []              195      PSIG      Test Temp.      sYsTEM    F Hold Time  10 MINUTEs
 
PSL-1, NIS-2TRACKING NO. S            L-2          33 FORM NIS-2          (Back)                  Sheet    2  of
: 9. Remarks            A HYDROSTATIC PRESSURE TEST WAS SUCCESSFULLY PERFORMED ON THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
: 10. Inspection Report Numbers:            M95-166 FOR      'A'EADER M95-070 FOR      'B'EADER APPLICABLE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                [ ] Replacement
[X ] Modification conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date% ( lR'5,              19 OwnersorOwne s Desig ee, Title CERTIFICATE OF INSERVICE INSPECTION
                                                    '\
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                              National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO. S L 8 -                  33 FORM NIS-2 OiVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                            Florida Power & Light Co.                        Date: 12/13/95 P. O. Box 529100                              Sheet:  3              of 3 Miami, FL 33152                                  Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A I A                          PCM &#xb9;: 058-295 Jensen Beach,  FL 34957
: 3. Work Performed By:              Florida Power  & Light Co.,  6501 SA1A Hwy., Jensen Bch., FL 34957
: 4. Identification of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other        Year    Replaced          ASME Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or            Stamped Material                          No.            No.                              Replacement          (Yor N)
TEE 8" X 8" X 6"  TIOGA PIPE        HEAT  &#xb9;                    UTC 381931                A'
                                                                                                    'B'D'R SA 234 WPB        SUPPLY          N07397          N/A          RIR 22806      1995        MOD.            NO FLANGE 6"      TIOGA PIPE        HEAT  &#xb9;                    UTC371 232                A'
                                                                                                    'B'D'R SA 105        SUPPLY          539 TNT          N/A          RIR 17907      1995        MOD.            NO STUD 3/4"-1 OUNC2A      ALLIED          HEAT  &#xb9;                                              A'
                                                                                                    'B'D'R SA 193 GR.B7    NUT & BOLT        91521          N/A        RIR 1J-0091    1994        MOD              NO STUD 3/4"-10UNC2A      ALLIED          HEAT  &#xb9;                                              A'
                                                                                                    'B'D'R SA 193 GR.B7    NUT & BOLT      88147-GP          N/A        RIR 1 J4I043    1994        MOD              NO STUD 3/4"-1 OUNC2A      ALLIED          HEAT  &#xb9;                                              A'
                                                                                                      'B'D'R SA 193 GR.B7    NUT 8 BOLT        51122          N/A        RIR 1H-1100      1993        MOD NUT, HEAVY HEX 3/4"-10UNC2B      ALLIED          HEAT  &#xb9;                    UTC 373362                A'
                                                                                                      'B'D'R SA 194 GR.6    NUT & BOLT        N784D          N/A          RIR 22763      1995        MOD
 
PSL-1, NIS-2 TRACKING NO. S L 8 -              34 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS FPL                              As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power    & Light Co.                    Date: 12/1 I/95 P. O. Box 529100                              Sheet:    I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O.  &#xb9;: N/A 6501 South Hwy. AIA                          PCM &#xb9;: N/A Jensen Beach,    FL 34957                  NPWO &#xb9;: 8214
: 3. Work Performed By:                  Florida Power    & Light Co.                  WO &#xb9;: 95012906-01 6501 South Hwy. A1A                            WCD    &#xb9; 0198 Jensen Beach,    FL 34957
: 4. (a) Identification of System        CCW HX 2A & 2B                              Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VARIABLESPRING SUPPORT                                  Expiration Date N/A (Mark Number)            CC-2073-531 (c) Code Class:    N/A (SUPPORT)
: 5. (a) Applicable Construction Code and Addenda:            ANSI B31.1      1977 ED. Code Case:              N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components:        1973  Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other        Year      Replaced      ASME Code Component or      Manufacturer Serial or Heat          Board    Identification Built Repaired or          Stamped Material                              No.            No.                              Replacement      (Yor N)
VARIABLESPRING          BERGEN            PART  &#xb9; SUPPORT 16VS          PATTERSON          BP-3100F-1 6      N/A            N/A        1982      REPLACED          NO VARIABLESPRING BERGEN                      PART  &#xb9;                    UTC 377925 SUPPORT 16VS        PATTERSON            BP-3100F-16        N/A        RIR 27324      1995  REPLACEMENT
: 7. DESCRIPTION OF WORK:                  DURING INSPECTION OF THE CCW, THE SPRING CAN WAS FOUND TO BE RUSTED AND CORRODED. ENGINEERING DETERMINED THAT IT SHOULD BE REPLACED DURING THE REFUELING OUTAGE.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) []
OF Other: VT1    []        VT2[]              VT3 [X]                      PSIG      Test Temp.
Hold Time
 
PSL-1, NIS-2TRACKING NO. S            L-2          34 FORIN NIS-2          (Back)                  Sheet    2  of      2
: 9. Remarks            FINALASSEMBLY INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
: 10. Inspection Report Numbers:            M95-464 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date                        19 AS Owners orOwnei's    eslg  e,TItle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State  or Providence    of Florida and employed  by  Arkwright  Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Ownei's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property'damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO. S L                  8-      35 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL
: 1. Owner                                Florida Power    & Light Co.                    Date: 12/11/95 P. O. Box 529100                              Sheet:    1                of 2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O.  &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach,    FL 34957                  NPWO &#xb9;: 8212
: 3. Work Performed By:                  Florida Power    & Light Co.                  WO &#xb9;: 95020723-01 6501 South Hwy. A IA                            WCD &#xb9; Jensen Beach, FL 34957                                    0203'b)
: 4. (a) Identification of System        CCW HX 2A & 2B                              Type Code Symbol Stamp N/A Authorization No. N/A Component Identification        VARIABLESPRING SUPPORT                                  Expiration Date N/A (Mark Number)            CC-2073-441 (c) Code Class:    N/A (SUPPOR'Q
: 5. (a) Applicable Construction Code and Addenda:            ANSI B31.1      1977 ED. Code Case:                    N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1973 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other        Year Replaced                ASME Code Component or        Manufacturer Serial or Heat          Board    Identification Built Repaired or                Stamped Material                              No.            No.                              Replacement            (Y or N)
VARIABLESPRING          BERGEN            PART  &#xb9; SUPPORT 15VS          PATTERSON        BP-3100F-1 5      N/A            N/A        1982            REPLACED        NO VARIABLESPRING BERGEN                      PART  &#xb9;                    UTC 380514 SUPPORT 15VS        PATTERSON          BP-3100F-15        N/A        RIR 29831    1995    REPLACEMENT
: 7. DESCRIPTION OF WORK:                  DURING INSPECTION OF THE CCW, THE SPRING CAN WAS FOUND TO BE RUSTED AND CORRODED. ENGINEERING DETERMINED THAT IT SHOULD BE REPLACED DURING THE REFUELING OUTAGE.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT)    []
Other: VT1    []        VT2[]              VT3[X]                      PSIG              Test Temp.              F Hold Time
 
PSL-1, NIS-2 TRACKING NO. S            L-2          35 FORM NIS-2            (Back)                  Sheet    2  of
: 9. Remarks            FINALASSEMBLY INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
: 10. Inspection Report Numbers:            M95-121 APPUCABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No      N/A signed        Nk 25ciw                                                      Date      (21 )l            19  IS Owners or OwneVS    esig  e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the OwneVs Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date          L)~          tf
 
PSL-1, NIS-2 TRACKING NO.              SL-2<-      ~636 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.              Date:      12/1/95 P.O. Box 529100                        Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucio Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                  PCM&#xb9;: 009-293m
: 3. Work Performed By:            Florida Power & Light Co.              PWO&#xb9;: 3640 6501 South Hwy. AlA WO &#xb9;:      94025062 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification of System:      Chemical 8 Volume Control Type Code Symbol Stamp    N/A V2462                                            Authorization No.        N/A (b) Component Identification:                                                                    Expiration Date          N/A (Mark Number)
(c)  Code  Class:  2 a) Applicable Construction Code and Addenda: ASME SECTI. III, 1971 ED; SUMMER '73 Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Rcpaircd or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other          Year      Replaced      ASME Component          Manufacturer      Serial or Heat  Board                        Built    Repaired      Code or                                    No.        No. Identification                    or        Stamped Material                                                                                  Replacement (Yor N) 2 PISTON CHECK          ROCKWELL              NA                    SA 182 TP 316      1983        Replaced VALVE 2 PISTON CHECK ANCHOR DARLING 8/N E-T401-9-16                NA      SA 351,CF 8M        1993    Replacement VALVE 2 SCH 160PIPE          SANDVIK          HT&#xb9; 468341        NA      SA 312, TP 304      NA      Replacement VALVE-PIPE WELD              FPL          WELD TRAV&#xb9;                    ER 308          1995    Replacement FW 2000                                954225 VALVE-PIPE WELD              FPL          WELD TRAV&#xb9;        NA          ER 308                  Replacement FW 2001                                954226 PIPE - TEE WELD            FPL          WELD TRAV&#xb9;        NA          ER 308                  Replacement FW-2002                                954471
: 7. Description of Work:    REPLACE VALVE DUE TO SEAT LEAKAGE. NEW WELDS ADDED FW 2000, 2001 & 2002 S/N E-T401-9-1 6
: 8. Tests Conducted:      Hydrostatic Other. VT1 X
                                                  ~  VT2 X Pneumatic VT3 Nominal Operating Pressure (ISLT)
                                                                                    ~pstg          Test Temp.    ~'F
 
PSL-2, NIS-2 TRACKING NO.                  SL-2<-        ~036 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A LIQUID PENETRANT EXAM AND HYDROSTATIC TEST WAS PERFORMED OF ALL WELDS.
: 10. Inspection Report Numbers:              OST Hydro Rpt 11/10/95 APPLiCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the'rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed 0    er or
                                ~  ~    p ibvr SLitov' ei's Designee, Title Z,I            Date,    c. I        19  ~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this OwneVs Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719    FL Com      &#xb9;60 nspectoVS Signature                                        National Board, State, Providence and Endorsements Date                                19~4.~
 
PSL-1, NIS-2 TRACKING NO.            SL-2          ~83?
                                ~            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.              Date:      11/25/95 P.O. Box 529100                        Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM &#xb9;: 082-193M
: 3. Work Performed By:              Florida Power  & Light Co.              PWO&#xb9;: 8994 6501 South Hwy. A1A WO &#xb9;:      94009303 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:      N/A
: 4. (a) Identification    of System:    Safety Injection Type Code Symbol Stamp          N/A V3523 Authorization No.              N/A (b) Component Identification:                                                                    Expiration Date                N/A (Mark Number)
(c)  Code  Class:    2 a) Applicable Construction Code and Addenda:            ASME SECTION III; 1974 EDITION          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer    National      Other        Year      Replaced            ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                      No.        No. Identification                                  Stamped Ol'eplacement Material (Yor N)
DISC ASSMEMBLY        TARGET ROCK            HEAT III        NA    SA 479- TP 316      1983    Replacement IG 4041
: 7. Description of Work:      REPLACE DISC ASSEMBLY DUE TO SEAT LEAKAGE
: 8. Tests Conducted:      Hydrostatic Other. VT1
                                                  ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure (ISLTI
                                                                                    ~pstg          TestTemp.        ~'P    X
 
PSL-2, NtS-2TRADKtNG NO.                SL-2        ~037 FORM NIS-2 (Back)                                        Sheet 2 of 2 R    s'eki3G&e-          7        wspsekoh            R)~
: 9. Remarks:                                      tt bg              VTR        1    i+@~
: 10. Inspection Report Numbers:        0+QG-Q            g+
APPUCABLE MANUFACTURES DATA REPORTS To BE ATTAciiED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner o      ei's Designee, Title Go I/      LG(        Date~art      2, 19~5
                            ~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719    FL  Com&#xb9;60 Inspectoi's Signature                                      National Board, State, Providence and Endorsements Date                                  19'
 
PSL-1, NIS-2 TRACKING NO.            SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.                Date:      11/29/95 P.O. Box 529100                          Sheet:      I of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM &#xb9;: 082-193M
: 3. Work Performed By:                Florida Power & Light Co.                PWO&#xb9;: 7323 6501 South Hwy. A1A WO &#xb9;:      93018650 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identification    of System:      Safety Injection Type Code Symbol Stamp      N/A V3551 Authorization No.        N/A (b) Component Identification:                                                                      Expiration Date          N/A (Mark Number)
(c) Code Class:      2 (a) Applicable Construction Code and Addenda:            ASME Sect III 1974 Ed / Sum 75 Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer    National      Other        Year      Replaced        ASME Component          Manufacturer          Serial or Heat  Board                        Built    Repaired        Code or                                        No.        No. Identification                  of        Stamped Material                                                                                      Replacement (Y or N) sc    em            arget  o                                                                    ep ace Assembly                                                                TP 347 isc    em            arget  o                    0        2288              4 9              ep acement Assembly                                  0000352220                    TP 347
: 7. Description of Work:        Replaced disc/stem assembly due to seat leakage
: 8. Tests Conducted:          Hydrostatic Other. VT1            VT2 Pneumatic VT3
                                                                                        ~
Nominal Operating Pressure (ISLT) psig  Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.              SL-2                                                  FORM NIS-2 (Back)                                      Sheet 2 of 2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        PA~ Q6          ROE~
APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                    Repair  +Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed          Au            s< p<<w+ s ov.                            Date  Qlv    Q.tt    19 9-'0 ne    Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
                                      >r    Commissions Inspector's Signature                                    National Board, State, Providence and Endorsements Date                                19 is
 
FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCESe Ae Required by the Provisions of the ASME Code, Section lil                                                        ~ g c~/4 Not to Exceed One Day's Production                                                            Pg.)of        2
  . Manufacturedandcenlfledby              Tar et Rock Cor .                1966E Broadhollow Rd; Farmingdale,                                    NY      11735 (name and address ol IIPT Car(rica(a Ho(derl
: 2. Manufactured for Florida        Power h          Light Co.; Fort Pierce,                    FL 34954 Iname and address ot Purchase(I
: 3. Location of installation St. Lucie Plant; densen Beach,                              FL 34957 (name ahd addr ~ stl
: 4. Type:
204600-1                        SA-479 347                        75    ksi                      N/A                                        1994 (drawrns no.l                (mat I. Soec. ho.l          (tensile strehetht                      ICRNI                          (year oualtl 1974                  Summer          1975                                                          None
: 5. ASME Code, Section III, Oivision 1:
(adrtronl              (addenda datal                        IC(asst                    (Code Case no,l N/A                                  N/A                                      N/A
: 6. Fabricated in accordance with Const. Spec. IOiv. 2 only)                                        Revision                              Oate (no.l
: 7. Remarks:
Disc Spare      part for valve                  model no. 75C-023 Part of Stem Assembly, P/N 200571-5
: 8. Nom. thickness (in.l                      Min. design thickness (in.l                  Oia. IO (ft (tt in.l                Length overall (tt  8(  in.)
: 9. When applicable, Certificate Holders'ats Reports are attached for each item of this report:
Part or Appurtenance                              National                          Part or Appurtenance                            National Serial Number                                Board No.                              Serial Number      ~                      Board No.
in Numerical Order                                                                  in Numerical Order (1)
N/A                      (26)
N  A (2)                                                                              (27)
N  A                                                            (28)
(3)
(4)                                                                              l29)
(5)                                                                              {30)
(6)                                                                              (31) l7)                                                                              l32)
(8)                                                                              (33)
(9)                                                                              {34)
{10)                                                                                l35) l I II                                                                              {36)
(12)                                                                                {37)
(13)                                                                                (38)
{14)                                                                                (39)
(1 5)                                                                              (40)
(16)                                                                                (41)
(17)                                                                                (42)
(I8)                                                                                {43) l19)                                                                                l44)
{20)                                                                                (45)
(21)                                                                                (46)
(22)                                                                                {47) l23)                                                                                (48)
(24)                                                                                {49) l25)                                                                                (50)
: 10. Oesign pressure                                                                                F. Hydro. test pressure                                    at temp. F (wtwn aooacso(el
'upplemental information in the form of lists. sketches, ot drawings may be used provided l1) sire is 8)) x 11. I2) lnfotmation in items 2 and 3 on this
                                                              ~
i t Amb e n oats Repon i~ ktc(uded on each sheet. ~ I3) each sheet is numbered and the number of sheets is recorded at th ~ top of this form.
l12/88)                                          This fohn (800040) may be obtained from the order oept.. AsM8. 22 Law orive.~ 8ox 2300.~ Faitfie(d.~ NJ 07007.2300.
Reprint pig 1)
 
PSL-1, NiS-2TRACKtNG NO.                SL-2      ~039 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.              Date:      11/25/95 P.O. Box 529100                        Sheet:    -
1 of Miam, FL 33152 Unit:        2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:        NA Jensen Beach, FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By            Florida Power  & Light Co.              PWO    &#xb9;:    4906 6501 South Hwy. A1A WO &#xb9;:        95025620 JensenBeach, FL34957 CWO &#xb9;: NA                Process Sheet:  N/A
: 4. (a) Identification  of System:    Main Steam Type Code Symbol Stamp    N/A MV-08-1 B                                          Authorization No.        N/A (b) Component Identification:                                                                    Expiration Date          N/A (Mark Number)
(c) Code Class:    2 a) Applicable Construction Code and Addenda:                        NA                          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National      Other          Year      Replaced      ASME Component        Manufacturer      Serial or Heat  Board                          Built    Repaired      Code of                                    No.        No. Identification                    or        Stamped Material                                                    s Replacement (Yor N)
SEAL WELD              FPL          WELD TRAV.&#xb9;        NA        SA-105                    Replacement FW-2001                                954246
: 7. Description of Work:      REMOVE / REPLACE SEAL WELD TO FACILITATEVALVE REPAIR
: 8. Tests Conducted:      Hydrostatic Other. VT1
                                                ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure ttSLT)
                                                                                    ~psig          Test Temp.    ~'F  X
 
PSL-2, NIS-2TRACKING NO.                  SL-2        039 FORM NIS-2 (Back)                                        Sheet 2 of 2 9.Remarks:        Q    Qsska&r"WQ                    trtst-'re.'crhQrt      >for 4'ski a/ra                ~%5 p.rrttt)rtsse8                ~d        ~IkcsseZ Q
a V~            g C~r4F ~8
: 10. Inspection Report Numbers:          Iti/ii  Q $ Q gQ g APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACKED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                              SR I          Sv/v-      ISI        Date  kv ?S          ta 'rr.
e  or    er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions            NB7719 FL        Com&#xb9;60 Inspector's Signature                                        National Board, State, Providence and Endorsements Date                      rh          19  5i
 
PSL-1, NIS-2 TRACKING NO.              SL-2                                              FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section XI
: l. Owner:                          Florida Power  & Light Co.                Date:      12/2/95 P.O. Box 529100                          Sllect'        of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. AIA                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM    &#xb9;: NA
: 3. Work Performed By:              Florida Power & Light Co.                  PWO&#xb9;:      1122 6501 South Hwy. AIA WO&#xb9;:        95019529 Jensen Beach, FL 34957                                IA CWO &#xb9;: NA              Process Sheet: N/A
: 4. (a) IdentificationofSystem:          MainSteam Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component                      V8211 Expiration Date          N/A IdentiTication:
(Mark Number)
(c) Code Class:      2 ASME Section III 1989 Ed / No Add          Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer      National        Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                    No.          No. Identification                    of        Stamped Material                                                                                      Replacement (Yor N) net    us                aw                                                                    ep ace 1  3/8 x 8 unc 2A                                                          Gr B7 n et tu s          ovaMac ne            eat o                        A 193                    ep acement 1  3/8'    8 unc 2A                      8868243/92397                    Gr B7 net    us                aw                                                4                    ep ace 1  3/8 x 8 unc 2B                                                          Gr2H n et    uts      A  ie  ut    ot        eat o                              4                  ep acement 1  3/8'    8 unc 2B                          Q2293A                        Gr7
: 7. Description of Work:      Replaced inlet flange bolting due to corrosion.
: 8. Tests Conducted:          Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig  Test Temp.
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORM NIS-2 (Back)                                          Sheet 2 of      2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. InspectionReport Numbers:          f8&#xc3;g 5          c2  l  I    t APPLiCABLE MANUFACTURE'S DATAREPORTS TO BE ATl'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                            +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                      J ~M P~~(      GRr Owner r Owner's Designee, Title
                                                      - lGI                  D  t~ t,19                ~+
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory            Mutual  Engrg Assoc.
have inspected the components described in this      Owner's    Report during operating    cycle  C3 starting on 05/94,  and  state that  to the best of my knowledge  and  belief,  the  Owner  has performed    examinations  and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions inspector's Signature                                        National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.                SL-2                                                  FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                            Florida Power  & Light Co.                Date:      12/12/95 P.O. Box 529100                            Sheet:    1  pf Miami, FL 33152 Unit:      2
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3  Work Performed        By.'lorida Power & Light Co.                            PWO&#xb9;: 2499 6501 South Hwy. A1A WO &#xb9;:      95003094 Jensen Beach, FL 34957 CWO &#xb9;:                Process Sheet:  N/A
: 4. (a) Identification      of System:        Main Steam Type Code Symbol Stamp      N/A Authorization No.          N/A (b) Component Identification:          V8213 Expiration Date          N/A (Mark Number)
(c) Code Class:            2
    ) APPlicable Construction Code and Addenda:                  ASME Sect III 1989 Ed/No Add              Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of            Manufacturer      National        Other          Year      Replaced      ASME Component              Manufacturer        Serial or Heat    Board                        Built    Repaired      Cpde No.          No. Identification                    Of      Stamped OI'aterial                                                                                    Replacement (Yor N) n  et ange tu                      aw                                                                      ep ace 1  3/8 x Sun 2A                                                              Gr B7 n  et ange tu                  ova              eat  o                        88~93                  ep acement 1  3/8 x Sun 2A                              8868243/92397                    Gr B7 n et  ange ut                    aw                                                                      ep ace 1  3/8'    8un 2B                                                            Gr2H n  et ange ut          Iie    ut    ot        eat o                                                  ep acement 1  3/8 x Sun 2B                                Q2293A                        Gr7
: 7. Description of Work:              Replaced inlet flange bolting due to corrosion
: 8. Tests Conducted:            Hydrostatic Other: VT1            VT2 Pneumatic VT3
                                                                                            ~
Nominal Operating Pressure (ISLT) pslg    Test Temp.            'F
 
PSL-2, NIS-2 TRACKING NO.                  SL-2                                                  FORM NIS-2 (Back)                                          Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:      fr< re i"-I g I G 8 5 APPLICABLE MANUFACTURE'S DATA REPORTS To BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                          A.ne-            v'- l<l                Date  MC I 3 19~5' Own r r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to,the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Ownei's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or toss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.              SL-2                      FP FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                        Florida Power  & Light Co.              Date:      12/5/95 P.O. Box 529100                          Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                Florida Power & Light Co.                PWO    &#xb9;:  1122 6501 South Hwy. A1A WO&#xb9;:        95019530 Jensen Beach, FL 34957                                1A CWO    &#xb9;: NA          Process Sheet: N/A
: 4. (a) Identification    of System:      Main Steam Type Code Symbol Stamp    N/A V8207 Authorization No.        N/A (b) Component Identification:                                                                        Expiration Date          N/A (Mark Number)
(c) Code Class:      2 a) Applicable Construction Code and Addenda:            ASME Sect lii 1989 Edition / No Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer      National      Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                      No.          No. Identification                    or        Stamped Material                                                                                      Replacement    PorN) u    net                  aw                                                                    ep ace 13/8'x8unc2A                                                              Gr 87 tu    net              ova              eat  o                              93              ep acement 1 3/8 x 8 unc 2A                          8868243/ 92397                  Gr 87 ut net            SPS2aw                                                  194                ep ace 1 3/8 x 8 unc 28                                                          Gr7 ut  n et        Ahe    ut    ot        eat o                                94              ep acement 1 3/8 x 8 unc 28                            Q2293A                        Gr7
: 7. Description of Work:      Replaced inlet flange bolting
: 8. Tests Conducted:          Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig    Test Temp.
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                    FORM NIS-2 (Back)                                        Sheet 2 of      2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        'W Glic2- i ~~
APPLiCASLE MANUFACTuRE'S DATAREPORTS To SE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                Gk arRIi      WM IN(
n  ror    n r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, Nls-2 TRACKING NO.              SL-2                                              FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power &, Light Co.              Date:      11/27/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3    Work Performed By              Florida Power & Light Co.                PWO&#xb9;: 5002 6501 South Hwy. A1A WO&#xb9;:        95028509 Jensen Beach, FL 34957                                1A CWO &#xb9;: NA              Process Sheet: N/A
: 4. (a) Identification    of System:      Main Steam Type Code Symbol Stamp      N/A V8201 Authorization No.        N/A (b) Component Identification:                                                                        Expiration Date          N/A (Mark Number)
(c) Code Class:      2 a) Applicable Construction Code and Addenda:            ASME Sect III 1989 Edition/no addenda      Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of        Manufacturer      National      Other          Year      Replaced      ASME Component            Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                      No.          No. Identification                    or        Stamped Material                                                                                      Replacement (Yor N) u      ne    ange            aw                                                                    ep ace 1  3/8 x 8 unc 2A                                                        Gr B7 u      n et  ange      ie  u      ot        eat os                        ESK705                  ep acement 1  3/8 x 8 unc 2A                        8868243/92397                  Gr B7 ut  n et ange              aw                                                  94                ep ace 1  3/8 x 8 unc 2B                                                        Gr 2H ut  n et  ange      ie  u      ot        eat  o                                              ep acemen 13/8xaunc2B                                  02293A                        Gr7
: 7. Description of Work:          Replaced inlet bolting.
: 8. Tests Conducted:          Hydrostatic Other: VT1            VT2~
Pneumatic VT3
                                                                                      ~
Nominal Operating Pressure (ISLT) pslg    Test Temp.            'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORM NIS-2 (Back)                                        Sheet 2 of      2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        N/tn  I  6 APPLICABLE MANUFACTuRE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of A thorization No.: N/A Signed                              o  Ge      (. WSuW          5      D t    QOV~,19'K Owne      Ow e s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions tnspectoi's Signature                                      National Board, State, Providence and End orsements Date    ILiOV'      >              , 19~5
 
PSL-1, NIS-2 TRACKING NO.              SL-2                      I FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                          Florida Power  & Light Co.                Date:      12/12/95 P.O. Box 529100                          Sheet:      I of Miami, FL 33152 Unit:
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3    Work Performed By                Florida Power & Light Co.                  PWO&#xb9;: 2511 6501 South Hwy. A1A WO&#xb9;:        95002850 Jensen Beach, FL 34957                                1A CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identification      of System:      Main Steam Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component Identification:          V8208 Expiration Date          N/A (Mark Number)
(c) Code Class:            2 a) Applicable Construction Code and Addenda:                ASME Sect III 1989 Ed/No Add              Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification      of Components Repaired or Replaced      and Replacement Components:
Type of              Name of          Manufacturer      National        Other          Year      Replaced      ASME Component            Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                        No.          No. identification                    or        Stamped Material                                                                                        Replacement (Y or N) n et    ange tu                  aw                              A                                      ep ace 1 3/8 x 8un 2A                                                              Gr B7 n  et  ange  tu              ova              eat o                                93              Rep acement 13/8 x8un2A                                8868243/92397                    Gr B7 n et ange ut                    aw                              A                                      ep ace 1 3/8 x 8un 2Blnlet                                                            Gr2H ange  u            ie    Ut    ot        eat o                                94              ep acemen 13/8 x8un2B                                  Q2293A                        Gr7
: 7. Description of Work:            Replaced inlet flange bolting due to corrosion
: 8. Tests Conducted:            Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
VT.3                            Test Temp.              LF Other: VT1            VT2                                    psig
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                    FORM NIS-2 (Back)                                          Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:
APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATfACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                              +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                        Sri  PCA    Soot/-    IS                    CeIe~llZ, Ie 'RS n    r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board            of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by            Factory  Mutual  Engrg Assoc.
have inspected the components described in this          Owner's  Report  during  operating  cycle  P8 starting on 05/94,  and  state that  to  the best  of my  knowledge  and belief, the Owner    has performed    examinations  and and taken  corrective  measures    described  in this Owner's Report  in accordance    with the  requirements  of the  ASME    Code,  Section    XI. 1989  Edition, no  addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                          National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO. S L                8-      45 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI
: 1. Owner-                              Florida Power  & Light Co.                      Date: 12/18/95 P. O. Box 529100                              Sheet:    1            of 3 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O.  &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: 016-290 Jensen Beach, FL 34957                      NPWO &#xb9;: 8882
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95024868-01 6501 South Hwy. A1A                            WCD &#xb9;: 0242 Jensen Beach, FL 34957
: 4. (a) Identification of System        CCW HEAT EXCHANGER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        2A SHELL SIDE DRAIN                                    Expiration Date N/A (Mark Number)
(c) Code Class:    3
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                        N/A Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
                                                                                                        'b)
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other        Year      Replaced      ASME Code Component or      Manufacturer Serial or Heat        Board      Identification Built Repaired or            Stamped Material                              No.            No.                                Replacement        (Y or N)
FLANGE"S/0          TIOGA PIPE        HEAT  &#xb9;                      UTC 380442                  2A HX SA 105 150&#xb9;          SUPPLY          8861721          N/A          RIR 29303    1995      DRAIN MOD.          NO PIPE -6"        TIOGA PIPE          HEAT &#xb9;                                                  2A HX SA 106 GR. B        SUPPLY            33366          N/A      RIR 3RB-1677    1990      DRAIN MOD.
FLANGE%"BL          TIOGA PIPE          HEAT &#xb9;                    UTC 3825939                  2A HX SA 105&#xb9;            SUPPLY          8079587          N/A          RIR 31617    1995      DRAIN MOD.
: 7. DESCRIPTION OF WORK:                  EXISTING DRAINS WERE DEGRADED AND INEFFECTIVE.
MODIFICATIONWAS COMPLETED TO INCREASE EFFECTIVENESS.
: 8. Test Conducted:          Hydrostatic [X ]              Pneumatic    []                  Nominal Operating Pressure (ISLT) []
Other: VT1    []        VT2[X]          VT3 []              165      PSIG        Test Temp.      SYSTEM    F Hold Time  10 MINUTEs
 
PSL-1, NIS-2TRACKING NO. S            L-2          45 FORM NIS-2            (Back)                  Sheet    2  of
: 9. Remarks            A HYDRosTATIG PREssURE TEsTwAs succEssFULLY PERFQRMED QN THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
: 10. Inspection Report Numbers:          . M95-307 APPLICABLE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate      of  Compliance We certify that the statements made in the reportare correct and this [              ] Repair      [ ] Replacement
[ X ) Modification conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Date  De< ~4,              19 ~S OwnersorOwn      SDes    nse, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors  and  the State  or Providence  of Florida  and employed  by  Arkwright  Mutual Insurance Company have inspected the components described in this        Owner's Report during  operating cycle P8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
xl PSL-2, NIS-2TRACKING NO. S            L-2        45 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.,Owner                            Florida Power  & Light Co.                      Date: 12/13/95 P. O. Box 529100                              Sheet:  3          of 3 Miami, FL 33152                                Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. 8: N/A 6501 South Hwy. A1A                          PCM  &#xb9;: 016-290 Jensen Beach, FL 34957
: 3. Work Performed By:              Florida Power  & Light Co.,  6501 SA1A Hwy., Jensen Bch., FL 34957
: 4. Identification of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other        Year      Replaced    ASME Code Component or Manufacturer Serial or Heat            Board      Identification Built Repaired or        Stamped Material                                        No.                                Replacement      (Yor N)
STUD 3/4" 10UNC2A    ALLIED NUT        HEAT  &#xb9;                                                2A HX SA 193 GR.B7      AND BOLT          51122          N/A        RIR 1H-1100    1995    DRAIN MOD.
NUT, HEAVY HEX 3/4" 10UNC28    ALLIED NUT        HEAT  &#xb9;                      UTC375495                  2A HX SA 194 GR. 2H      AND BOLT          E04277          N/A          RIR 25731    1995    DRAIN MOD.      NO
 
PSL-1, NIS-2 TRACKING NO. S L 8 -                46 FORM Ii/IS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMEi ITS PPL                            As Required by the Provisions of the ASME Code Section      XI
: 1. Owner                                Florida Power & Light Co.                        Date: I I/13/95 P. O. Box 529100                                Sheet:    I          of 2 Miami, FL 33152                                  Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A IA                          PCM&#xb9;: N/A Jensen Beach, FL 34957                      NPWO    &#xb9;: 7706
: 3. Work Performed By:                  Florida Power & Light Co.                      WO &#xb9;: 95013850-01 6501 South Hwy. A1A                              WCD &#xb9;: 0184 Jensen Beach, FL 34957
: 4. (a) Identification of System        INTAKECOOLING WATER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVEV-21165                                            Expiration Date N/A (Mark Number)
(c) Code Class:
: 5. (a) Applicable Construction Code and Addenda:          ASME 1977 S 1977 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identi6cation    of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other        Year      Replaced    ASME Code Component or Manufacturer Serial or Heat              Board      Identification Built Repaired or          Stamped Material                              No.          No.                                Replacement      (Yor N)
NUT, HEAVY HEX        ALLIEDNUT                                      RIR 2J-1 002 1 1/2"%UN 2B        AND BOLT                                      SA194GR.7              REPlACEMENT        NO NUT, HEAVY HEX        ALLIEDNUT                                        RIR 26598 1 1/2"%UN 2B        AND BOLT          Q2293A                      SA 194 GR. 7            REPLACEMENT        NO NUT, HEAVY HEX        ALLIEDNUT                                      RIR 2H4253 1 1/2"%UN 2B        AND BOLT          Q2293A                      SA 194 GR. 7    1993  REPLACEMENT        NO NUT, HEAVY HEX        ALLIEDNUT                                      RIR2J-1243 1 1/2"NUN 2B        AND BOLT          Q2293A                      SA 194 GR. 7            REPIACEMENT        NO BOLT, STUD            ALLIEDNUT                                        RIR 26597 1 1/2"4UNX61/2"        AND BOLT        52869-FC          N/A      SA 193 GR. B7 1995      REPlACEMENT        NO
: 7. DESCRIPTION OF WORK:                BOLTING WAS WORN DUE TO NORMALWEAR AND TEAR AND FPL RECOMMENDED REPlACEMENT
: 8. Test Conducted:          Kydrostatic []                Pneumatic    []                  Nominal Operating Pressure (ISLT) [ X]
Other. VT1      []        VT2[X]          VT3 []                sYsTEM PSIG          Test Temp.        sYsTEM F Hold Time      4 HQURs
 
PSL-1, NIS-2TRACKING NO. S              L-2          46 FORM NIS-2              (Back)                Sheet    2  of
: 9. Remarks            IsLT wAs sATIsFAGToRILY PERFQMED oN YALYEsB-21165
: 10. Inspection Report Numbers:            M95-308 APPLICABLE MNrUFACTURER'S OATA REPORTS To BE ATTACIKD Certificate      of    Compliance We certify that the statements made in the report are correct and this [            ) Repair      f X ) Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Signed                                                                        Date LL Owners or        s De  nee, TIUe CERTIFICATE OF INSERVlCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bo6er and Pressure Vessel inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any wananty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-1 NIS-2 TRACKING NO. S L 8 -
                                                                        ~                                              47 FORiM NIS-2 OIVlAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions  of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                        Date: 11/13/95 P. O. Box 529100                              Sheet:  I          of  2 Miami, FL 33152                                  Unit: 2
: 2. Plant                                  St. Lucie Nuclear Plant                          P.O. &#xb9;: N/A 6501 South Hwy. A1A                            PCM &#xb9;: 129-295 Jensen Beach, FL 34957                        NPWO &#xb9;: 8779
: 3. Work Performed By:                    Florida Power  & Light Co.                      WO &#xb9;: 95024463-01 6501 South Hwy. A I A                            WCD &#xb9;: 0236 Jensen Beach, FL 34957
: 4. (a) Identification of System          INTAKECOOLING WATER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification          LINE I-24"-CW-75                                        Expiration Date N/A (Mark Number)          24" ELBOW (VALVESIDE) ICW "A" HEADER (c) Code Class:              3
: 5. (a) Applicable Construction Code and Addenda:            ASME 1977 S 1977 ADD. Code Case:                      N/A (b)    Applicable Edition of Section XI  for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National          Other                Replaced    ASME Code Component or Manufacturer Serial or Heat                  Board        Identification          Repaired or      Stamped Material                              No.          No.                                Replacement      (Yor N)
UTC 378384 BOLT, STUD          ALLIED                                      SA 193 GR. B7
      '1  1/4"WX51/2      NUT & BOLT          M53716                    RIR 27708              REPLACEMENT          NO BOLT, STUD                                                        UTC 379705 1 1/4"WUN2AX13          ALLIED                                        SA 193 GR. B7 CUT FROM ROD          NUT & BOLT          62413          N/A          RIR 2J<232            REPLACEMENT          NO UTC 333268 NUT, H. HEX        ALLIED                                      SA 194 GR. 2H 1 1/4" WUN2B      NUT & BOLT          E97187                    RIR 2J<761              REPlACEMENT          NO
: 7. DESCRIPTION OF WORK:                  STUDS AND NUTS WERE REPLACED BECAUSE THEY WERE NICKED AND WORN DUE TO NORMALWEAR AND TEAR.
: 8. Test Conducted:            Hydrostatic [ ]                Pneumatic    []                Nominal Operating Pressure (ISLT) [ X]
Other. VT1    []        VT2[X]            VT3 []                sYsTEM PSIG        Test Temp.        sYsTEM F Hold Time        4 HDURs
 
PSL-1, NIS-2 TRACKING NO. S L 8 -              47 FORNI NIS-2        (Back)                  Sheet    2  of
: 9. Remarks            ISLT WAS SATISFACTORILY PERFOMED FOR THE FLANGE TO VALVE CONNECTION AT VALVE I-MV-21-3.
: 10. Inspection Report Numbers:            M95-306 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Signed  W~W                                                                Date    ('L  I IS          19~X Owners or      er's    ignee, TiUe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engineering Associates have inspected the components described in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my knowledge and belief, the Ovmer has performed examinations and taken corrective measures descnbe in this Owner's Report in accordance viith the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                              National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2TRACKING NO. S          L-2>>8-          48 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section    XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/18/95 P. O. Box 529100                              Sheet:  I          of 2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. AIA                          PCM ff: N/A Jensen Beach,  FL 34957                    NPWO    &#xb9;: 8210
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95012782-01 6501 South    Hwy. A IA                        WCD &#xb9;: 0195 Jensen Beach, FL 34957
: 4. (a) Identification of System        INTAKECOOLING                              Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        SB 21163                                              Expiration Date N/A (Mark Number)
(c) Code Class:    3
: 5. (a) Applicable Construction Code and Addenda:            ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable Edition of Section XI  for Repairs  and  Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other        Year Replaced        ASME Code Component or        Manufacturer Serial or Heat          Board    Identification Built Repaired or        Stamped Material                            No.            No.                              Replacement      (Y or N)
BOLT, SA 193 GR.B7                          HEAT  &#xb9;                    UTC 341998 1  1/4"-SUN2AX7"  NOVA MACHINE          79916            N/A        RIR 3J-1052    1994  Replacement        NO BOLT, SA 193 GR.B7                          HEAT&#xb9;                      UTC 341991 1  1/4"SUN2AX20  NOVA MACHINE          M51 481          N/A      RIR 3J-1052B    1994  Replacement        NO NUT, HEAVY HEX SA 194 GR. 2H      ALLIED NUT        HEAT&#xb9;                      UTC 374489 1 1/4-8UN2B    AND BOLT CO.          151593          N/A        RIR 24742      1995  Replacement        NO
: 7. DESCRIPTION OF WORK:                  BOLTING AT VALVE21163 REPLACED BECAUSE OF NORMAL WEAR AND TEAR
: 8. Test Conducted:          Hydrostatic []                  Pneumatic  []                  Nominal Operating Pressure (ISLT) [X ]
Other: VT1 []          VT2 [X]            VT3 []          sYsTEM      PSIG      Test Temp.      sYsTEM      F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S              L-2          -59 FORM NIS-2            (Back)                    Sheet  2  of
: 9. Remarks            AN IsLT wAs sUGGEssFULLY PERFQRMED QN THE FLANGED CONNECTIONS AND WITNESSED BY A CERTIFIED Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95-302 APPLICABLE MANUFACTURER'S OATA REPORTS TO BE ATTACHED Certificate    of      Compliance We certify that the statements made in the report are correct and this [ ] Repair                    t X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Signed Owners or Own    s DB I  nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel
    ,  Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.            SL-2                                              FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP                        As Required by thc Provisions of the ASME Code Section XI I. Owner:                          Florida Power  & Light Co.                Date:      12/13/95 P.O. Box 529100                            Sheet:      I  of Miami, FL 33152 Unit:
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach,  FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power  Er, Light Co.              PWO&#xb9;: 3572 6501 South Hwy. A1A WO &#xb9;:      95001866 Jensen Beach, FL 34957 CWO      &#xb9;: NA        Process Sheet:  N/A
: 4. (a) IdentificationofSystem:          ComponentCooling Water Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component Identification:        SS-21-1A Expiration Date          N/A (Mark Number)
(c) Code Class:        3 (a) Applicable Construction Code and Addenda:              ASME Sect lli / 1989 Ed No Add          Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components  Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer      National      Other          Year      Replaced        ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired        Code of                                      No.          No. Identification                  or        Stamped Material                                                                                      Replacement (Y or N) u s                um                                                193                    ep ace 1  -Suncx 7"        Industries                                        Gr B7
            ~iu s                ova              eat o                            193                  ep acement 1  -Suncx 7          Machine            S090323                      Gr B7
: 7.  'escription of Work:      Replaced strainer studs due to normal corrosion.
: 8. Tests Conducted:          Hydrostatic Other: VT1            VT2 Pneumatic
                                                              ~        VT3
                                                                                        ~
Nominal Operating Pressure (ISLT) psig  Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                    FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:              MM95-1395 8 MM95-1918 APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                            SP            V/ L/  l5              Date  ~l(819~7, ner o    nei's Designee, Title CERTIFICATE OF. INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle P8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date                      /3, 19~
 
PSL-1, NIS-2TRACKING NO. S          L-2          50 FORM NIS-2 OWVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 01/18/96 P. O. Box 529100                              Sheet:  I          of  4 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A IA                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO &#xb9;: 8218
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95012801-03    & 04 6501 South    Hwy. AIA                        WCD &#xb9;: 0188, 189,  & 0190 Jensen Beach, FL 34957
: 4. (a) Identification of System        INTAKECOOLING WATER                        Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        LINE I-30-CW-20                                        Expiration Date N/A (Mark Number)          SPOOL 14 ZiV-68-I Ec 2 EL 1-30"-CW-77-2 (c) Code Class:                        EL I-30 CiV-76-2
: 5. (a) Applicable Construction Code and Addenda:            ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable Edition of Section Xl for Repairs and Replacement Components: 1989 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other        Year Replaced          ASME Code Component or      Manufacturer Serial or Heat          Board    Identification Built Repaired or          Stamped Material                              No.            No.                              Replacement      (Yor N)
NUT,HH-SA-194    ALLIED NUT            HEAT  &#xb9;                    UTC 333268 1 1/4"-8UN2B    AND BOLT              E97187          N/A        RIR 2J-0761    1994  REPLACEMENT          NO BOLT, SA 193    ALLIEDNUT              HEAT  &#xb9;                    UTC 373936 1 1/4"4UN2AX9" AND BOLT                8894177          N/A        RIR 24401    1995  REPLACEMENT          NO BOLT, SA 193      ALLIED, NUT          HEAT  &#xb9;                    UTC 331564 1 1/4"-8UN2AX9"      AND BOLT            70251          N/A        RIR 3J-0190    1994  REPLACEMENT NUT,HH-SA-194      ALLIED, NUT          HEAT &#xb9;                      UTC 374489 1 1/4"-8UN2B      AND BOLT            151593          N/A        RIR 24742    1994 REPLACEMENT            NO
: 7. DESCRIPTION OF WORK:                  MATERIALSWORN DUE TO NORMALWORN, TEAR AND CORROSION.
FPL RECOMMENDATIONTO REPLACE
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) [ X]
Other: VT1    f]        VT2[X]            VT3 [X]            SYSTEM  PSIG      Test Temp.          SYSTEM F Hold Time        4 HoURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          50 FORM NIS-2            (Back)                  Sheet    2  of        4
: 9. Remarks            ISLT WAS SATISFACTORILY PERFORMED FOR THE FLANGED CONNECTIONS.
FINAL INSPECTION WAS PERFORMED FOR SUPPORT BY A VT3 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:            M95-411, M95452, 8 M95-454 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  f X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorizati No N/A Signed                                                                        Date ners or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board      of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
    'By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                              National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO. S L 8 -              50 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section    XI
: 1. Owner                            Florida Power  & Light Co.                      Date: 01/18/96 P. O. Box 529100                              Sheet:  3        of 4 Miami, FL 33152                                  Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. I/: N/A 6501 South Hwy. A1A                            PCM  &#xb9;: N/A Jensen Beach,  FL 34957
: 3. Work Performed By:              Florida Power  & Light Co.,  6501  SAIA Hwy., Jensen Bch., FL 34957
: 4. Identification of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other        Year    Replaced    ASME Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or        Stamped Material                          No.          No.                                Replacement    (Yor N)
BOLT-SA193                        HEAT&#xb9;                      UTC 375439 5/8"-1 1UNC2A  NOVA MACHINE      6R-59444          NIA          RIR 25175      1995  Replacement      NO NUT,HH -SA194    ALLIEDNUT        HEAT    &#xb9;                    UTC 374489 1 1/4"-8UN2B    AND BOLT          151593          NIA          RIR 24742      1995  Replacement      NO NUT, HH- SA194    ALLIEDNUT        HEAT    &#xb9;                    UTC 374486 1 1/8"4UN2B      AND BOLT          152550          NIA          RIR 24742      NIA  Replacement      NO U-BOLT A36 WI                    U-BOLT HT.&#xb9; A563 GR.A NUT      BERGEN          8096325                      UTC 373874 2 1/2" PIPE SIZE  PATIERSON      NUTS-3D589                    RIR 3AH4375      1993  Replacement      NO NUT, HH- SA194    ALLIEDNUT          HEAT  &#xb9;                    UTC 375497 5/8"-11UNC2B      AND BOLT          L63812          NIA          RIR 25731      1995  Replacement BOLT- SA1 93                      HEAT  &#xb9; 5/8"-1 1UNC2A  NOVA MACHINE        62477          N/A        RIR 1 J4199    1994  Replacement      NO BOLT- SA193                        HEAT  &#xb9;                    UTC 372561 5/8"-1 1UNC2A  NOVA MACHINE        62477          N/A        RIR 1J4224      1994  Replacement      NO BOLT- SA193                        HEAT  &#xb9;                    UTC 375439 5/8"-1 1UNC2A  NOVA MACHINE      6R-59444          N/A          RIR 25175      1995  Replacement      NO BOLT- SA193    ALLIED NUT        HEAT  &#xb9;                    UTC 372557 5/8"-11UNC2A      AND BOLT        88147-GP          N/A        RIR 1 J-0247    1994  Replacement      NO BOLT- SA193    ALLIED NUT        HEAT  &#xb9;                    UTC 374493 5/8"-11UNC2A      AND BOLT        88147-GP          N/A          RIR 24742      1995  Replacement      NO BOLT- SA193    ALLIED NUT        HEAT&#xb9;                      UTC 331566 1 1/4"-8UNC2A    AND BOLT          70251          N/A        RIR 3J-0190B    1994  Replacement      NO BOLT- SA193    ALLIEDNUT          HEAT  &#xb9;                    UTC 331565 1 1/4"-8UNC2A    AND BOLT        8078593          NIA        RIR 3J-0190A    1994  Replacement      NO BOLT- SA193    ALLIEDNUT          HEAT  &#xb9;                    UTC 331567 1 1/4"-8UNC2A    AND BOLT          62480          NIA        RIR 3J4190B      1994    Replacement
 
PSL-2, NIS-2 TRACKING NO. S          L-2        50 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS FPL                          As Required by the Provisions of the ASME Code Section XI
: 1. Owner                            Florida Power  & Light Co.                      Date: 01/18/96 P. O. Box 529100                              Sheet:  4        of 4 Miami, FL 33152                                Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM&#xb9;: N/A Jensen Beach, FL 34957
: 3. Work Performed By:                Florida Power  & Light Co.,  6501 SA1A Hwy., Jensen Bch., FL 34957
: 4. Identification  of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other        Year    Replaced    ASME Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or      Stamped Material                          No.          No.                              Replacement    (Yor N)
FLANGE, 4" SA 105            N/A            N/A            N/A            N/A        N/A    Replaced        NO FlANGE, 4"                        HEAT  &#xb9;                    UTC 378328 SA 105        TIOGA PIPE        8860283          N/A          RIR 27287    1995  Replacement      NO PIPET, 30"X4" SA 234            N/A            NIA            NIA            NIA        NIA    Replaced        NO PIP ET, 30"X4"                    HEAT CODE SA 234        TIOGA PIPE          71            N/A        RIR 2J4292    1994  Replacement      NO SUPPORT CW-3001437 A36 (ANGLE)          NIA            NIA            N/A            N/A        N/A    Replaced DUBOSE ANGLE, A36        NATIONAL        HEAT  &#xb9;                    UTC 369804 3" X3" X3/8"        ENERGY          J5966          N/A        RIR 3AK4606    1995  Replacement SUPPORT CW-3001437 A36 (ANGLE)          N/A            NIA            NIA            NIA        N/A    Replaced DUBOSE ANGLE, A36        NATIONAL        HEAT  &#xb9;                    UTC 370160 1 1/2"X1 1/2"X1/4"    ENERGY          J2705          NIA        RIR3AK4617      1995  Replacement      NO
 
PSL-Q NIS-2 TRACKING NO.                SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                          Florida Power & Light Co.                Date:      11/29/95 P.O. Box 529100                          Sheet:      I  of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:      NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                Florida Power & Light Co.                PWO&#xb9;: 3601 6501 South Hwy. A1A WO &#xb9;:        95001741 Jensen Beach, FL 34957 CWO    &#xb9;:            Process Sheet: N/A
: 4. (a) Identification    of System:        Reactor Coolant Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                        PCV-1100F Identification:
Expiration Date          N/A (Mark Number)
(c) Code Class:    1 a) Applicable Construction Code and Addenda:              ASME Sect III 1971 Ed/W72Add.            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components      Repaired or Replaced and Replacement Components:
Type of              Name of            Manufacturer    National      Other          Year      Replaced      ASME Component          Manufacturer          Serial or Heat  Board                        Built    Repaired      Code of                                        No.        No. Identification                    of        Stamped Material                                                                                        Replacement (Y or N) ug stem          is er  ontro s                                        4                      ep ace Assembly                                                              Typ 316 ug stem          is er  ontro s          eat o          A              4 9        199      Replacement Assembly                                    99911-1                    Typ 316
: 7. Description of Work:        Replaced plug and stem assembly due to normal wear.
: 8. Tests Conducted:          Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2~        VT3                        psig  Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:      cf          Q APPLicABLE MANUFACTURE'S DATAREPORTS TO BE ATl'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair Q Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed    kA  Own
                            'e    GS ndnn      5vnv r Owner's Designee, Title Date    ~0~+7,      19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the'Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2TRACKING NO. S          L-2          52 FORM NIS-2 OYVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power & Light Co.                      Date: 12/07/95 P. O. Box 529100                            Sheet:    I          of 2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O.  &#xb9;: C92933-90719 6501 South Hwy. AIA                          PCM&#xb9;: N/A Jensen Beach,    FL 34957                  NPWO    &#xb9;: 8234
: 3. Work Performed By:                  Florida Power    & Light Co.                  WO &#xb9;: 95028726-01 6501 South    Hwy. AIA                        WCD &#xb9;: 'N/A Jensen Beach, FL 34957
: 4. (a) Identification of System        CCW SUPPLY HEADER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVESB14528                                            Expiration Date N/A (Mark Number)
(c) Code Class:            3
: 5.  (a) Applicable Construction Code and Addenda:          ASME 1974 S 1974 ADD. Code Case:                    N/A (b) Applicable Edition of Section  XI  for Repairs  and Replacement Components: 1989 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other        Year Replaced          ASME Code Component or      Manufacturer Serial or Heat            Board    Identification Built Repaired or          Stamped Material                              No.            No.                              Replacement      (Y or N)
HENRY PRATT                                          SA516 VALVE- 10"            CO.            D 0065-2-1        N/A        GR. 70        N/A      REPLACED          YES UTC 383726 HENRY PRATr                                    SA 516 GR. 70 VALVE- 10"            CO.            DD74-1-1          N/A      RIR 3H-0911A    1993    REPLACEMENT        YES
: 7. DESCRIPTION OF WORK:                  PLANT WAS UNABLE TO TIE-IN PER PCM 058-295 (PERM. CONT. A/C)
VALVEWAS LEAKINGAT THE SEAT AT A RATE OF 2 GAL.PER MINUTE.
: 8. Test Conducted:          Hydrostatic [ ]                  Pneumatic []                  NominaI Operating Pressure (ISLT) [ X]
Other: VT 1    []        VT 2 [X ]          VT3 []            sYsTEM PSIG        Test Temp.        sYsTEM F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          52 FORM NIS-2          (Back)                  Sheet    2  of
: 9. Remarks            ISLT FOR THE FIANGED CONNECTIONS ON VALVESB-14528 WAS SATISFACTORILY PERFORMED.
: 10. Inspection Report Numbers:            M95-467 APPUCAB LE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  f X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              NIA Certificate of Authorization No N/A Owners or Owner's D    ignee    Ie Date    >2 I      7,        ttt~f.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ff8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and
    'taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or toss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date                                                    196 V
 
                                                          ) p    gQ-o            t II Page        <          ot  ~(
FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORTS-0                                                    R  PUMPS OR VALVES As Required by the Provisions of the ASME Code. Section III. Division                              1 Pg.            of
: 1. Manufactured and cenrfied by              HENRY PRATT COMPANY                                  T    V Iname and address ot N Canrhcate Holder)
: 2. Manutactured for            FLORIDA POWER AND LIGHT (name and address ot Parcnaser or ownen
: 3. Locauon of installation            ST. LUCIE UNIT 2 (name and address)
: 4. Model No.. Series No. or Type
                              ~                                  Drawing          N/A            Rev.        N/A            CRN        N/A
: 5. ASME Code. Section Ill, Division 1:              1974                  SUM    74                  3                        N/A (edmon)              Iaddenda dater                Idassi              (Code Case no.)
VALVE                                            10
: 6. Pump or valve                              Nomina( inlet size                            0 detsize (in.)                                lin. I 7  Mat    r,-ai.        SA516 GR70            Bonnet                                    SA351 CFSM            Bolting      SAl        GR8 Br)d                                                            Disk (al                        (bl                          (cl                          (dl                            (el Cen.                        Nat'I                        Body                        Sonnet                          Ois((
Holder's                    Board                        Serial                        Serial                        Serial Serial No.                    No.                          No,                            No.                            No.
N  A              802H41790                            N/A                      T180-802H41790                            N/A                      T18 -4
'Supplemental intonnation in form of rists. sketches, or drswines mav be used provided (1) size is 8)( x 11. 121 Information in items I through 4 on this oats Repon is induded on each sheet, (3) each sheet is numbered and the number of sheets is recorded st the top of this form.
() 2JB())                  This form (E00037) may be obtained from the Order Oept., ASME, 22 Law orivesos 2300. Faireeld. NJ 07007.2300.
 
lR ~              ~      I 20F2 page~et                                                                          0074 FORM NPV-1 (kcckl B. Remarks
: 9. Design conditions                              psi        200                4F or valve      pressure    class (pressurel                    ttemoereturer 1
: 10. Cold working pressure              285              psi at 1004F
: 11. Hydrostatic test      450              psi. Disk differential test pressure                165                                          psi CERTIFICATION OF DESIGN Design Spectfication cerufied by                                                P E  State FL            R 13797 Design Report certified by        KE I TH  LB%                                  P.E. State
                                                                                                                                                  .gP CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this re pon are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section lli, Division 1.
N1030                                    Expires N Certificate of Authorization No.
Date~" I< '7~            ame                                                      Signed (N Cert>fkeste Holdert                                  (eutnonte        eseotsuvet CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board            of Boiler and Pressure Vessel Inspectors and the State or Province of                                                  and employed by of                                                              have inspected the pump, or valve, descnbed in this Oats Report on
                -I                , 19 ~~. and state that to the best of my knowledge and belief, the Certtflcate Holder                    has constructed this pump. or valve. in accordance with the ASME Code, Section III, Division 1.
By signing this certificate.'eithor the inspector nor his employer makes any warranty, expressed or implied. concerning the manner for component described in this Data Report. Furthermore, neither the inspoctor nor his employer shall be liable in any any personal injury or property damage or a loss of any kind arising from or connected          with  this inspection.
Date 3'- r~.,'+      Signed    ~          opted  I  pector>
w Commissions
                                                                                          '        >5        Xf-I (Net'I. Bd. lied. endorsernents) state or prov. snd no.l I1) For manually operated valves only.
 
PSL-1, NIS-2TRACKING NO. S          L-2          53 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL
: 1. Owner                                Florida Power  & Light Co.                    Date: 12/07/95 P. O. Box 529100                              Sheet:  I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.o.f/: C92933-90719 6501 South Hwy. A1A                          PCM f/: N/A Jensen Beach, FL 34957                    NPWO ff: 8234
: 3. Work Performed By:                  Florida Power  & Light Co.                  WO //: 95028735-01 6501 South Hwy. A1A                            WCD //: 'N/A Jensen Beach, FL 34957
: 4. (a) Identification of System        CCW SUPPLY HEADER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVESB14530                                          Expiration Date N/A (Mark Number)
(c) Code Class:            3
: 5. (a) Applicable Construction Code and Addenda:          ASME 1974 S 1974 ADD. Code Case:                    N/A (b) Applicable Edition of  Section XI for Repairs  and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other      Year      Replaced      ASME Code Component or      Manufacturer Serial or Heat          Board    Identification Built Repaired or        Stamped Material                              No.            No.                            Replacement      (Yor N)
HENRY PRATI                                          SA516 VALVE- 10"            CO.          D44725-8-1        N/A          GR. 70      N/A      REPLACED          YES UTC 383729 HENRY PRATT                                    SA 516 GR. 70 VALVE- 10"            CO.            0D74-1-2          N/A      RIR 3H-0911B    1993  REPLACEMENT        YES
: 7. DESCRIPTION OF WORK:                  PLANT WAS UNABLE TO TIE-IN PER PCM 058-295 (PERM. CONT. A/C)
VALVEWAS LEAKINGAT THE SEAT AT A RATE OF 2 GAL.PER MINUTE.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                Nominal Operating Pressure (ISLT) [ X]
Other: VT1    []        VT2[X]            VT3 []              sYSTEM PSIG      Test Temp.        SYSTEM F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S            L-2                                                    FORIN NIS-2          (Back)                  Sheet  2  of
: 9. Remarks            ISLT FOR THE FLANGED CONNECTIONS ON VALVESB-14530 WAS SATISFACTORILY PERFORMED.
: 10. Inspection Report Numbers:            M95-466 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed Owners or Owner'slg        e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date                                                    19~>
 
                                                        )R      g]4-oq f(
Page        <          ot  ~(
FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORT%                                                          R PUMPS OR          VALVES As Required by the Provisions of the ASME Code, Section III, Division                                  1 Pg.      1      of
: 1. Manufactured and certified by              HENRY PRATT C(NPANY                        00          T A tname and address ot N cernricate Hoideri
: 2. Manufactured for              LO IDA      PO~R AND LIGHT (name and address  ot Parcnaser or owneri
: 3. l.ocahon of installation ST>>  LUC I E      UNIT    2 (name and addiessi
: 4. Model No.. Series No.. or Type                              Orawing            N/A            Rev          N/A              C((N        N/A
: 5. ASME Code, Section III, Oivision 1:
1974                  SUM    74                  3                            N/A (editionl              taddenda cater                Icrassr                (Code Case no.i VALVE                                            10tr                                    t nit
: 6. Pump or valve                              Nominal inlet size                              Outlet size (in.l                                  lin. I 7  M t nal      Bod                            Bonnet (al                          (b)                          (c)                            (d)                              (el Cen.                          Nat'I                        Body                          Bonnet                              Oisk Holder's                        Board                        Serial                        Serial                            Serial Serial No.                        No.                          No.                            No.                              No.
N A                  802H41790                            N/A                          T18 N A                  802H41790                            N/A                          T18        -4
'supplemental information in term ot asts. sketches, or drawings may be used provided (1) size is 8)) x 11. (21 information in items 1 through 4 on this oats Report is indud<<d on each sheet, l3) each sheet is numbered and the number ol sheets is recorded at the top of this form.
112/88)                      th(s form (E00037)may be obtained from the order oept.. ASME, 22 taw Drive. 8ox 2300.          Fair eield. N3  07007-2300.
 
la ~ -~~~~
20F2 psife~of FORM NPV-1 (back)
DD7".
: 8. Remarks
: 9. Oestgn    conditions                              psj        200                eF  or valve pressure        class ipressure>                    itempcrsturer
: 10. Cold working pressure                285              psi at 1004F
: 11. Hydrostatic test                        psi. Oisk differential test pressure                165                                        psl CERTIFICATION OF OESIGN Reg. no.
Oesign Specification certified by Oesign Report cartigred by        KE I TH  L P.E. State P.E. State                        RI<    o.~~M'p                  o qP CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code. Section III. Division 1.
N Certificate of Authorization No.
N1030                                      Expires Oste  ~" ~~ ~~            arne                                                        Signed IN Cenrricste Holder>                                      leutnonze      esentstrver CERTIFICATE OF SHOP INSPECTION I~ the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure                      Vessel Inspectors and n
the State or Province of                                                    and employed by ot                                                                have inspected the pump, or valve. descnbed in this Oats Report on
              - /
                                  , 19  ~~.      and state that to the best of my knowledge and belief. the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section III. Oivision 1.
By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or implied. concerning the component described in this Oats Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Oats 2-rg..  '+      Signed nzed I  peer pn Commissions
                                                                                            '        )K        ZLf INet'I. Bd. (ind. endorsementsi state or prov. snd no.l l1)For manually operated valves only.
 
                                                                  , PSL-1, NIS-2 TRACKING NO.              SL-2        054 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F            ~
As Required by the Provisions of thc ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                Date:      11/2/95 P.O. Box 529100                            Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA JensenBeach, FL 34957                      PCM&#xb9;: NA
: 3. Work Performed By:            Florida Power  & Light Co.                PWO&#xb9;: 8801 6501 South Hwy. A1A WO &#xb9;:      94007594 JcnscnBeach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification of System:      Containment Spray Type Code Symbol Stamp      N/A V07120 Authorization No.          N/A (b) Component Identification:                                                                      Expiration Date            N/A (Mark Number)
(c) Code Class:    2 ASME SEcnoN III 1986 EomoNNo AoosNoA      Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section  XI Utilized for Repairs    and Replacement Components: 1989 Edition.
: 6. Identification    of Components Repaired or Replaced and Rcplacemcnt Components:
Type of              Name of          Manufacturer      National      Other          Year      Replaced        ASME Component or          Manufacturer      Serial or Heat    Board      IdentiTication      Built    Repaired        Code Material                                    No.          No.                                        or Replacement    Stamped Yor Flange Stud            BF Shaw                NF          NA          SA  193          NA        Replaced    N)    N 1 1/4'    8 unc                                                          Gr  B7 Flange Stud        Allied Nut & Bolt      Heat No                      SA  193          NA      Replacement        N 1 1/4'    8 unc                        90755/TR N 27                    Gr  B7
: 7. Description of Work:      Replaced flange stud due to damage.
: 8. Tests Conducted:        Hydrostatic Other. VT1
                                                  ~      Pneumatic VT2 X          VT3
                                                                                'ominal Operating
                                                                                      ~pstg          TestTemp.    ~'F Pressure (ISLT)    X
 
                                                                        'heet PSL-2, NIS-2 TRACKING NO.
FORM NIS-2 (Back)
SL-2N-2 of 2 054
: 9. Remarks:          A satisfactory Inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:              MM95-1 524 APPUCABLE MAMUFAOTURES OATA REPORTS To BE ATfACHEO Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Owner o l4          .S    L rt s Designee, Title Wpv                  Date  It ~            19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719      FL Com      &#xb9;60 Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO. S L 8-                  55 FORM YiIS-2 OIVtAVERS REPORT FOR REPAIRS OR REPLACEIilENTS J    As Required by the Provisions of the ASME Code Section XI
: 1. Owner                              Florida Power & Light Co.                      Date: 11/17/95 P. O. Box 529100                            Sheet:  I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.O.//: 88929-92668 6501 South Hwy. A1A                          PCM I/: N/A Jensen Beach, FL 34957                    NPWO //: 8210
: 3. Work Performed By:                  Florida Power  & Light Co.                  WO 0: 95012782-02 6501 South Hwy. A1A                            WCD f/: 0197 Jensen Beach, FL 34957
: 4. (a) Identification of System        INTAKECOOLING WATER                        Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVEV-21162                                          Expiration Date N/A (Mark Number)
(c) Code Class:            3
: 5. (a) Applicable Construction Code and Addenda:          ASME 1977 S 1977 ADD. Code Case:                    N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year Replaced          ASME Code Component or Manufacturer Serial or Heat              Board      Identification Built Repaired or        Stamped Material                              No.          No.                              Replacement      (Yor N)
TRW MISSION      TAG I-V-21 678                    SA216 VALVE- 30"    VALVECO.          FIG. 15-SNF-921                  GR. WCB      N/A      REPLACED UTC 349242 SA 216 C&S VALVE        89G213801-                      GR. WCB VALVE- 30"        COMPANY            Z0663                      RIR 3J-1375    1995  REPLACEMENT          YES
: 7. DESCRIPTION OF WORK:                  DURING INSPECTION, M/M SUPV. DETERMINED THAT THE VALVE NEEDED TO BE REPLACED.
: 8. Test Conducted:          Hydrostatic []                Pneumatic  []                  Nominal Operating Pressure (ISLT) [ X]
Other. VT1      []        VT2[X]          VT3 []              SYSTEM PSIG        Test Temp.        SYSTEM F Hold Time        4 HQURs
 
PSL-1, NIS-2 TRACKING NO. S            L-2          55 FORM NIS-2            (Back)                  Sheet  2  of
: 9. Remarks            ISLT FOR THE FLANGED CONNECTIONS ON VALVEV-21162 WAS SATISFACTORILY PERFORMED.
: 10. Inspection Report Numbers:            M95-301 APPUCAIRE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [ X J Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Signed                                                                        Date    >~l11 Owners or Owne      Des nee, TrUe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components descnbed in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my krewledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
I By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concemlng the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
FORM NPV-1 CERTlRCATE                    HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR VALVESe Ae Required by the Provlelone of the ASME Code, section ill. Division 1 Pg. 1  of
*, ,                              .GLS Yalve Co., Mzlear Products Div.; 40 ~i~t Ave.; Westmont,                                                lL 6K
                                          ~
: 1. Manufactured and cert(f(ed by (nsn(s snd  sddtsss of Csn(nests N              Hc(dsr(
3  Location of installation Flori~
1Ori+    ~
g, Li~ QzPai1y; P.Q. KN 12S; Fort Pierce. Florida 34954
                                                          ~  Light  Ca (nsms t  +
snd address
                                                                                    ~ie of
                                                                                              ~
purchaser}  .
6501 RUUl A1A; (hsme snd sddfs ss(
                                                                                                                              ~        Heach,    Florid Model NoSeriea        Noor Zype Dual Plate                  g(,;~ 94-2PM1                N R
A            gg      N/A Ennea 1%4                      3                    N-133-1
: 5. ASMB Code. Section III, Oh(alon          1
                                                ~
(ed(t(onl            (addenda cats)                  (c(ass(            (Cods Case no.)
: d. pumper vahe                                  Nominal inlet aix X"                    Outlet aixe
: 7. Material:    Body                            Bonnet (In.l ol,m (Plate 148    e. m (in.l
                                                                                                                            ~, See    ~      Side ia)                            ib)                          ic)                              id)                          ie)
Cert.                          Nat'I                        Body                          Bonnet                          Oia)(
Holder's                        Board                        Ser(al                            Ser(al                        Serial Serial No.                        No.                            No.                              No.                          No.
'voo(smenta( information in form of asts, snatches. or drawings may he used provided l1) s(te is 1% x 11, l2) infonnaoon in items 1 through            i on th(>> osta ftsoort la inc(uded on sech sheet. (2) sech sheet is numbered snd the numosr of sheets is rscordeo at the too of th(s form.
(12/88)                        TNs ream (axe37) may be    o~      fm  the order oeot.. idML 22 ta      0~. do* 2200. Faeee.      M 0700T    2200 as  ~~~~
* 8(xty manufactured            by  CSS  Yalve    mhr F89-0606(Nl.          ~
M 0 89-05K?41(N)-01.
i          ~libby Fl~e Plates manufactured by QS Yalve F)        aLi~.
g'g-z -p- 05+
 
g ZJ-IVVS-P        ~      t      cs                      FORM NPV-1 t Back            Pg. 2 of                )
Certificate Holder's Senal ffo. 8        6 2<1(N)<1
      $ . Design conditions                              psj          100                  eF or vsl ~ pressure class ipreaeurel                    iternpereturel
: 9. Cold working pressure
: 10. Hydrostatic test                        psi. Disk differential teat pressure              1      1 pal
: 11. Remarks:
CHlTIFICATIONOF OKSIQN Design Specificadon certified by                                                P.E. State    ~~+                  R~~.      ~>
Design Report cartified by                                                      P.E. State                        Raga now CEllTIFICATIOF COMPUANCI We certif that the statements made in this report    ar ~ correct and  that this pump or valve conforms to the rules for construction of the ASM'ode, Section III, Division I.
N Certificate of Authorlxadon No.                                                                                    6/20/95
                                  , C5S  Valye    CO. Re.    ~~
W Ceroficete Holderl DiV.      SI~                Iwtnorieed representsdvel CSmFICATI OF IN4$%CTlON I. the undersigned. holding a valid commission issued by the National Board of Boger and Pressure Vessel In                            ors and the State or Province of                                                      and employed by of                                                              have inspected the pump, or valve. described in this Data Report on
                                            ~ and state that to the best ot my knowledge and begef the Certificate Holder has con structed thfa pump. or valve. in accordance with the AS ME Code, Secdon ill, Division 1.
By signing thfa certitlcat>>. neither the inspector nor hla employer
                                                                          +F            tbtual          ineeriw Associatian or implied. concerning the any              , axprea component deacrfbed ln this Oat>> Report. Furthermore, neither the inspector nor hfa employer shaw be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with thfa inapecdon.
Frp O          ~  +  Signed I        'n        orl chal Iffet'I.ad. finer. endoreeroentsi end ststeorprov. endno.l l 1) For manually operated valves only.
 
k((ILI larV.I I(        ~II>> v<<>>I              ~                                  ~.
                                                                                              -7'!
Aa Roe) r(red by. t)to Boo{alone            cf the ASN%                  Sect)on N, ()br.
(>>I,                                                                                                                                                                        1
~ 5 '>>      4'      I OfVfsiCn'.40        Cheart            AVe. 'MSStmat,                      IL 6Q559-11%
'l                        ; 1(,    )4AAltaured by
  ~  I                    0: ltanuaectured lor                                                                                      Shach          'laridi"BI%8-1m or fvweee w
(
L Locedon d  ~
                                                        ~~ g
                    '-'i4, Aae0 or Viho Inch)
              ~            ~  ~
(a) Mode{ No      (b) )t Cert(Acate HOMar's No'    " "'.:. 0er{al.;-                  Reglatret(on  ~  'd) Drawing',"                  .    *        ~    . ~,", (() Nat'I.    ~
(0) Year or Type'                  Ho,  .>>".                  No.".  ".            No.              -    {e) CIaae            . ed. No.          ~;  e~
(
h          1%g
{a)  ~
{10)
                            ~    r Olsf eaacneoon      or Sanaca fer ~
                                                                                                                                                                                        ~
                                                                                                                                                                                          '% '.". "':;-')'-
                        ~
L                                                                                            'p or Valve heaaure
                                                ~  4 Cold Wore)ny Procure
                                                        ~
Pressure {tete(ning tleeee1 IFtsA 1  '
                                                                                            ~
                                                                                          'pal et  10M '.  ':
ogpg+gai
                                                                                                                                  ~,
                                                                                                                                    ~ (4 A
                                                                                                                                        .'.'>>,                                                      II
                                                                                                                                                                                                          ~ ~
Mater{a( Spec. No.                          Nawfacturer I
                          ;      (e)
                                                                                                                                                  ~
S-.
                                                                                                                                                                                      ~    ~
                                                                                                                                          ~
{b) Forylnye                                                                                                  ~
qual>>'
                'l) t        ~
        ~
          '                  tot meweiy            operated valse on)y.:,':,        i."
                  '          Nupplemental aheeta ln terri ol )lath ebeaciee or draw(neo mey be used yeekSe) (1) a{ac le 4'lO' 11; N) (rv)orrnetlon ln
                ~          )tome 1 0 and 5 on d(e octa ((aport le inctuded on each sheet, and 0) each sheet le numbered and number ot eheeta
                                                                                                                                                    ~
le retorded at tetr oi this form.                                                                              ~            ~~                                  ~
                                            *:                    '' llew ierrrt {SCPj hwr ae eitaawd
~ ~
                'I
                    .".. {14Nl Ir r                                                          ~ '. O'er OaotANt,0' rjorn the
                                                                                                                        ~, rr>>>>eL  y~I ~      + Pl~>>r CO 0t (r
New VeA, N Y. 10011
                                                                                                                                                                            ~qayq .i~>> r      ' -      >    ~
 
Yc'i                    i'aQe    )Je                              , Ieaaatlel Qyec. HO.
                                                                            ~
V
      ,tq
                                                                  ~ r+
      ,r                                                                                          '
    '4          ~
                ~ ~
      .(,  ~
                                                                                  ,I ~
    'Q 4
4 IILLIILIL44          ~nr    'LI..
                                                  ~
ILILNIIIILIIIL      meyLLLL        21Q . LI.-
  ~
CStfHCAT% Of          ~ANCE
  .4.        ~
V We cenlfy aac    d>>      aaceenonce        made ln thla tepon ate cottecc endtt>>c thle pump, ot.valve. confom>>
aIIII "-
Oe tulae af Addenda Ya    m, N CNINcalt NQQattt Out ANN Cad&ere of Authokcedon No.
Tricentrlc Divisicn  .
LI3hl io uee Oe
                                                                                                                'S
                                                                                                                                        ~ IIII'4PIIIL 6/8l/%
oe    .
q ~
                                  ~;, '...,,
                                        ~...
DeelOn infonnedon on Sbeee anelyele tepott (Oeee le ec 1
                                                            '          ~,
onlyl on Oe ec CSRTPCNNN            'INON Deeiya epecl5cedone      ~led by (fl Scteee          cenNed by il),
                                                              ')1 spnelee not teeuited.        Lice nano eely.
                                  - ~ 'I-.v.'  <<1  .;,'2;,'-4'IgfPICA75 Of                        ~        Ngf!CT)OH I Oe undeteiined; hoNnI e veNd commlealon ieeued by oe Natonal Ioetd of loller end Aeee22te Weeal b~dore nd employed by *
                    ~ nd Oe eceee or ftevinco ef of                                                                hove Inepecced Oe pump. or vere, deecHbod ln Ole Deke hapotc m
                                                        )0~,                end easooecloee bee otmy IQnewledoe end beNet.oe N cenMlcea Holdaheecon eauceed Ole pump, er veiv>>. ln accordance vQOh Oe ASMI Code. Secdon N.
                    ~ y eiininy Ne ce&HceiII nQher oe Inepeceor not Ne employer mehee eny>>ettency eaptc>>eed et hapa4 eencendni
',V mav>>r Ier                      ~
0N equiptnenI deecrlbed ln Ne Dace hepotc. twthonnote. neioet Oe Inepeccot nor Ne etnployer eNI be Ielle In eny or ptope& darned ot e loca of eny              ~    etielne Aotn ot conneclei ah% ole @operon.
ss-c
                                            ~I>>an
                                                                                                                                                          'onwnleeione (traced  ee sea,    ~ aae Nal gL ~
 
PSL-1, NIS-2 TRACKING NO. S            L-2          56 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL
: 1. Owner                                Florida Power  & Light Co.                        Date: 12/27/95 P. O. Box 529100                                Sheet:  1          of  2 Miami, FL 33152                                  Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: C95934-90011 6501 South Hwy. A I A                          PCM  &#xb9;: N/A Jensen Beach, FL 34957                      NPWO &#xb9;: 8218
: 3. Work Performed By:                  Florida Power  & Light Co.                      WO &#xb9;: 95012801-03 6501 South Hwy. A I A                            WCD &#xb9;: 0189 Jensen Beach, FL 34957
: 4. (a) Identification of System        INTAKECOOLING WATER                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        VALVEV-21189                                            Expiration Date N/A (Mark Number)
(c) Code Class:
: 5.  (a) Applicable Construction Code and Addenda:        ASME 1971 S 1973 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other        Year      Replaced      ASME Code Component or      Manufacturer Serial or Heat        Board      Identification Built Repaired or          Stamped Material                              No.          No.                                Replacement      (Yor N)
VALVE- 4"                          SERIAL  &#xb9; SA 516 GR.70    HENRY PRATT          D0066-3-2        N/A            N/A        1977    REPLACED          NO VALVE- 4"                          SERIAL  &#xb9;                    UTC 377172 SA 516 GR.70      HENRY PRATT        DD343-1-2        N/A          RIR 26612      1995  REPLACEMENT        NO NUT,HH-SA194        ALLIED, NUT        HEAT  &#xb9;                    UTC 375497 5/8"-11UNC2B        AND BOLT          L63812          N/A          RIR 25731      1995  REPLACEMENT BOLTNA193        ALLIED, NUT        HEAT  &#xb9;                    UTC 372557 5/8"-1 1UNC2A      AND BOLT          88147-GP          N/A        RIR 1 J-0247  1994 REPLACEMENT
: 7. DESCRIPTION OF WORK:                  DURING INSPECTION, M/M SUPV. DETERMINED THAT THE VALVE NEEDED TO BE REPLACED.
: 8. Test Conducted:          Hydrostatic [ ]              Pneumatic    f]                  Nominal Operating Pressure (ISLT) [ X]
Other: VT1 []            VT2[X]          VT3 []                sYsTEM PSIG        Test Temp.        sYsTEM F Hold Time        4 HQURs
 
PSL-1, NIS-2 TRACKING NO. S L 8 -            '6 FORNI NIS-2          (Back)                  Sheet  2    of
: 9. Remarks            ISLT FOR THE FLANGED CONNECTIONS ON VALVEV-21189 WAS SATISFACTORILY PERFORMED.
: 10. Inspection Report Numbers:            M95-313 APPLICABLE MANUFACTURER's DATAREPDRTB To BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this [            ] Repair      [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization          N/A Signed                                                                        Date      /      ~7,        19 Own    s or Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of    florida  and employed by  Arkwright  Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date        ~          27                              19~a
 
PSL-I, NIS-2 TRACKING NO.              SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                          Florida Power & Light Co.                Date:      12/1/95 P.O. Box 529100                          Sheet:      I of Miami, FL 33152 Unit:      2
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3    Work Performed        By'lorida Power & Light Co.                          PWO&#xb9;: 3609 6501 South Hwy. A1A WO &#xb9;:      95001904 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet: N/A
: 4. (a) Identification      of System:      Reactor Coolant Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                        PORV V1475 Identification:
Expiration Date          N/A (Mark Number)
(c) Code Class:        1 a) Applicable Construction Code and Addenda:                ASME Sect III 1977 Ed / S 79 Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer    National      Other          Year      Replaced      ASME Component            Manufacturer          Serial or Heat  Board                        Built    Repaired      Code No.        No. Identification                    or        Stamped oi'aterial Replacement PorN) onnei                  arrett                                                                    ep ace Gr F316 onnei                rosy    a  e          ena  o                                    9 4      ep acement K7204-324002                  Gr F316
: 7. Description of Work:          Replace bonnet due to loose bonnet guide.
: 8. Tests Conducted:            Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
VT2          VT3                              Test Temp.            IF Other: VT1                                                    psig
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORII NIS-2 (Back)                                      Sheet 2 of      2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:
APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                        +    Replacement Type Code Symbol Stamp: N/A Certificate of Autho zation No.: N/A Signed ner r    neCs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions lnspectoCs Signature                                      National Board, State, Providence and Endorsements
 
                        ~
                          >>'    >>    ~  'r,  >>>>S    'I.'>>>>'>>>>>>'.I      >>>>>>>>>>>>'>> '.        I  ", >>;c '              '                  ~ >>',        .
* Ili              CL
(        L          re&
                                                          ~    I I    ~
J
                                                                                                                                                                                                            ~      ~  >>
                                                                                                              ~>>  ~
                    ~,    ~                    ~  ~              $0  ~            1
                                                                                                        >>  ~  >>      ~  II ~:I                  ~
                                                                                                                                                              >>  I  ~            I    I  II  II          I I
                                                                                                              >>          ~        ~    ~
                                                                                                                                              '          ~                        ~  ~  >>
                                                                                                                  ~
                                                                                                                                                                            ~
                    ~  ~                            ~      ~ ~      ~                                                                                          ~
                                                                              ~    '      ~                                        I      ~        ~        >>
                                                                                                                                                            ~
~
      '        ~                                                          ~ ~                                                                                  ~
                                                                                                                    ~ ~
                                                                                                                                                                                                        ~ ~  ~
                                                                                  ~        ~
                                                                                                                                                                    ~  >>    ~
1                      ~          ~
                                                                                                                                                                ~  >>    i
                                                                      ~,
    ~  ~                      ~      ~
1  ~            ~
I ~
          '                  ~    ~                                      ~ >>          ~                                                      i            ~
                                                                                                                                ~            ~          ~
              ~  ~
                                                                                                                                          ~                                                          ~  ~ >>
                                                                        ~      ~                                  ~ ~    a    ~    >>
                                                                                                                                                                                    ~ ~
            ~  ~    ~            >>                      ~ ~        ~              \  ~  ~        ~  >>                      ~        ~        >>
                                          ~  ~                                                                                                    1        ~        ~ >>
                                                                                                                                                                                                ~  '          ~
                                                                                  ~        ~                                                                                  ~ >>
                                                                                                                                                                                                                  ~  ~
                                                                                                    ~  ~  >>
                                                    ~ ~    I
 
~ ~ ~l P I
                                                                                                                                ~    '                                                                    ~ ~  I IW                      'j,i  a
                                                                                            ~  I                          ~    ~                    ~        I        ~      ~            I
                                                                                        ~            ~                                    ~    I '                    ~
          'c>i~j
                                                                                        ~                          ~        ~                                        ~                /g I I I
                                                                                                                                                                          ~  ~    I                                                                ~    '      I js i fr.''~
I  ~              ~
                                              ~ I    ~        ~                I        ~                      ~      ~
                                                                                                                                                                            ~            ~
L                                                                                ~
                                              ~      ~
                                                                '      ~                                                                                ~ ~
                                                                                                                                                ~
                                                    ~    I        I      ~        '
9 ~-":iW 7 "~5fipM9~vRQXLa ~JK8Ka.".F&~~~d,'W~~4~W" lj J J
g "i,
                                                                                                                                                                                                                                                                                    "\1
                      ~ '
                          ~ gg
                                ~
                                  ~ ~ ~
                                        ~
Iy
                                                    ~  ~
I
                                                              ~
                                                              ~
                                                                                  ~          ~
                                                                                                    ~
I Lt''[          ~  '
                                                                                                                                        ~
                                                                                                                                          ~
                                                                                                                                            ~
g'
                                                                                                                                                ~
I I
                                                                                                                                                                                ~
                                                                                                                                                                                  ~  ~
I I
                                                                                                                                                                                                    ~
                                                                                                                                                                                                    ~
                                                                                                                                                                                                      ~
                                                                                                                                                                                                        ~
                                                                                                                                                                                                            ~  ~      ~
                                                                                                                                                                                                                        ~
I
                                                                                                                                                                                                                            ~
                                                                                                                                                                                                                              ~ I
                                                                                                                                                                                                                                ~    I I
LI I  ~ ~
I I          I        ~
                                                                                                                                                                                                                                                                                      ,gl jL/
                                                                                                                                                                                                                                                                                          ~  I~
I I    ~                                    ~            '      ~        ~                          ~          I  ~  ~
                                                                                                                                                                                                          '        ~                                          I    ~  ~
i'
                                                                  ~          ~              I          I    I                    ~    ~                                                                    ~ ~
                                                ~    ~                ~      ~      ~                    ~,        '
                                                                                                                                                  ~ ~
                                                                                                            ~        ~            ~                        ~    ~                                                  1
                                                                                                                                                                                                                                  'I      I            ~            ~    I ~
                                            ~    ~ ~                ~            ~
                                                                                          '                        ~ .        I      ;  ~                                                                                          I  '                          I      1    ~
                                                                                                                                                                                                                                                                                    .?~I  '
                                                                                                  ~
I                      ~        ~    ~  ~                ~ I        '        '              ~      ~                      ~    I        ~      ~        ~
8  I
                                                                                                                                                                                                                                                                                    .J~    .g gs  "g
                                                        ~,      ~
L:,',
 
PSL-1, NIS-2 TRACKING NO.              SL-2      ~058 F          g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                    Florida Power & Light Co.                Date:      11/14/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:      NA Jensen Beach,  FL 34957                PCM&#xb9;: NA
: 3. Work Performed By.          Florida Power & Light Co.                PWO    &#xb9;:  4972 6501 South Hwy. A1A WO &#xb9;:      95027851 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification of System:      Safety Injection Type Code Symbol Stamp    N/A HCV-3635                                          Authorization No.        N/A (b) Component Identification:                                                                  Expiration Date          N/A (Mark Number)
(c) Code Class:    2 a) Applicable Construction Code and Addenda:                        NA                        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National        Other        Year      Replaced      ASME Component          Manufacturer      Serial or Heat  Board                        Built    Repaired      Code or                                    No.        No. Identification                  or        Stamped Material                                                                                Replacement (Yor N)
Seal Weld              NA                Ht No        NA        P8To P8            NA    Replacement (SI-2000)                              DT 6289                    ER 316
: 7. Description of Work:    'Remove seal weld for valve inspection and reweld following examination.
: 8. Tests Conducted:      Hydrostatic Other: VT1
                                                ~      Pneumatic VT2 X      VT3              ~prig          TeetTemp.    ~'P Nominal Operating Pressure (ISLT)    X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        OSS FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:
APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                    Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                        WPI        .U    I/-lSl                Date ~&II i            19~7 Own r r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this OwneVS Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
M            .k~
Inspectors Signature Commissions              NB7719 FL Com          &#xb9;60 National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO. S L          8-        59 FORM NIS-2 OiVFAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions  of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/18/95 P. O. Box 529100                            Sheet:  I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. AIA                          PCM &#xb9;: N/A Jensen Beach,  FL 34957                    NPWO &#xb9;: 8210
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95012782-01 6501 South    Hwy. AIA                          WCD &#xb9;: 0195 Jensen Beach,  FL 34957
: 4. (a) Identification of System        INTAKECOOLING                              Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        EXPANSION JOINT                                        Expiration Date N/A (Mark Number)            SJ-21-4A (c) Code Class:    3
: 5. (a) Applicable Construction Code and Addenda:            ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable  Edition of Section XI  for Repairs and  Replacement Components: 1989 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National        Other      Year Replaced          ASME Code Component or      Manufacturer Serial or Heat          Board    Identification Built Repaired or        Stamped Material                              No.            No.                              Replacement      (Y or N) 24" EXPANSION      PATHWAY              &#xb9; HT AMNT JOINTSA182 F316 BELLOWS                  &#xb9; PT B-14392                                        N/A    REPLACED          NO 24" EXPANSION                          HT&#xb9; 610VNE                    UTC 384322 JOINTSA182 F316        ABB/CE        PT&#xb9; B-1-7832                  RIR 3H-3361    1993  Replacement        NO BOLT, SA 193 GR.B7        ALLIED NUT          HEAT &#xb9;                    UTC 379706 1 1/4"- 8UN2A      AND BOLT CO.          90755          NIA        RIR 2H-1680    1993  Replacement        NO NUT, HEAVY HEX SA 194 GR. 2H      ALLIEDNUT            HEAT &#xb9;                    RIR 21-1002    1994/
1 1/44UN2B        AND BOLT CO. E97817/151593            N/A        RIR 24742    1995 Replacement          NO
: 7. DESCRIPTION OF WORK:                EXPANSION JOINT WAS REPIACED BECAUSE OF PITTING AND CORROSION.
BOLTING, BECAUSE OF NORMALWEAR AND.TEAR.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                Nominal Operating Pressure (ISLT) [X ]
Other. VT1    []        VT2[X]            VT 3  []        sYsTEM      PSIG      Test Temp.      BYBTEM      F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          59 FORM NIS-2          (Back)                  Sheet    2  of
: 9. Remarks            AN ISLT WAS SUCCESSFULLY PERFORMED ON THE FLANGED CONNECTIONS AND WITNESSED BY A CERTIFIED Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95-302 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                (X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date Dt'-1'-  ~
19 ~$
Owners or    ne    esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
8d                                              Commissions National Board, State, Providence and Endorsements Inspectors Signature Date
 
PSL-1, NIS-2 TRACKING NO.            SL-2                                              FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.                Date:      11/21/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:,,                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By.              Florida Power  & Light Co.              PWO&#xb9;: 4518 6501 South Hwy. A1A WO &#xb9;:      95018944 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet: N/A
: 4. (a) Identification    of System:      Safety Injection Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                      V3550 Identification:                                                                      Expiration Date          N/A (Mark Number)
(c) Code Class:      2 tern a) Applicable Construction Code and Addenda: ASME SEGT III 1974 Eomow SuM 75 Aoo Code Case: None (b) Applicable Edition of Section Xl Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer    National      Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                      No.        No. Identification                  ol        Stamped Material                                                                                      Replacement (Yor N) bise      em          arge  o                                                                    cp acc Assembly                                                              TP 347 isc                  arget  o                    0                                            ep accment Assembly                                0000352219                  TP 347
: 7. DescriptionofWork:          Replacedisc/stemassembly Note: Seal weld replaced Ref WO95030191        / NIS-2 SL-2-8-060
: 8. Tests Conducted:          Hydrostatic              Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                    psig  Test Temp.
 
PSL-2, NIS-2 TRACKING NO.                  SL                                                  FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector
: 10. Inspection Report Numbers:        1VlI41 9g ZGD f APPLICABLE MANOFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair  +Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed          4&              Zp )t.ftlvi    gv~        hSL          Date  ititttt eID-  19  W nsr o    nei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Insp'tor's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.              SL-2      061 i                                  g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                          Florida Power & Light Co.              Date:    11/24/95 P.O. Box 529100                        Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:      NA JensenBeach,  FL 34957                PCM&#xb9;: NA
: 3. Work Performed          By'Florida Power & Light Co.                      PWO&#xb9;: 5226 6501 South Hivy. A1A WO &#xb9;:      95030191 Jensen Beach,  FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification of System:        Safety Injection Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                        V3550 Identification:                                                                      Expiration Date          N/A (Mark Number)
(c) Code Class:        2 Applicable Construction Code and Addenda:          ASME SECTION III; 1980 EDITION            Code Case: None
      )
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification      of Components Repaired or Replaced and Replacement Components:
Type of                Name of        Manufacturer    National        Other        Year      Replaced      ASME Component            Manufacturer      Serial or Heat  Board                        Built    Repaired      Code No.        No. Identification                  of        Stamped OI'aterial                                                                                Replacement (Y or N)
SEAL WELD                  FPL          WELD TRAV&#xb9;        NA                                  Replacement FW-2003                                  954375
: 7. Description of Work        SEAL WELD 8 FILLET WELD
: 8. Tests Conducted:        Hydrostatic Other: VT1
                                                      ~      Pneumatic VT2 X        VT3              ~pstg          TestTemp.    ~'F Nominal Operating Pressure (ISLT)      X
 
PSL-2, NtS-2TRACKtNG NO.                          SL-2    ~061 FORM NIS-2 (Back)                                                Sheet 2 of 2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector
: 10. Inspection Report Numbers:              QCR: 2009 APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair            X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                  Cu,          9Z                                  Date ttAe<    2'I    19 er or    ei's Designee, Title 95'ERTIFICATE OF INSERVICE INSPECTION e
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;6 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719      FL Com      &#xb9;60 inspector's Signature                                      National Board, State, Providence and Endorsemants Date                                  19 JCC
 
PSL-1, NIS-2 TRACKING NO.              SL-2                                            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power  & Light Co.              Date:      11/20/95 P.O. Box 529100                          Sheet:      I of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3  Work Performed By            Florida Power & Light Co.                PWO&#xb9;: 5229 6501 South Hwy. A1A WO &#xb9;:      95030271 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet:  N/A
: 4. (a) Identification  of System:      Safety Injection Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component                    V3495 Expiration Date          N/A Identification:
(Mark Number)
(c) Code Class:    2 NA                        Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and.Replacement Components:
Type of            Name of          Manufacturer    National      Other        Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                    No.        No. Identification                    of        Stamped Material                                                                                    Replacement (Y or N) ea    e                                ea    o                                              ep acemen DT 6289 95-'33+%                                                                (P8 to P8)
: 7. Description of Work:      Remove and replace seal weld to facilitate valve work.
: 8. Tests Conducted:        Hydrostatic              Pneumatic              Nominal Operating Pressure (ISLT)
Other. VT1            VT2          VT3                    psig    Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                    FORM NIS-2 (Back)                                        Sheet 2 of      2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:            MM95-1892 APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                            +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                          sp f4sn sUpa2ulsa2.              ~<~  Dale  u~. 0>        19  ~D Owne o Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida        and employed by  Factory  Mutual  Engrg Assoc.
have inspected the components        described  in this Owner's Report during  operating  cycle  &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date            j-      ( -,19~~"
 
PSL-2, NIS-2 TRACKING NO. S L          8-        63 FORM NIS-2 OiVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section    XI
: 1. Owner                            Florida Power  & Light Co.                      Date: 01/18/96 P. O. Box 529100                              Sheet:  3          of 3 Miami, FL 33152                                Unit: 2
: 2. Plant                            St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach, FL 34957
: 3. Work Performed By:              Florida Power  & Light Co.,  6501 SA1A Hwy., Jensen Bch., FL 34957
: 4. Identification of Components Repaired or Replaced and Replacement Components:
Type of        Name of      Manufacturer      National        Other      Year      Replaced    ASMF Code Component or      Manufacturer Serial or Heat      Board      Identification Built Repaired or        Stamped Material                          No.          No.                                Replacement    (Yor N)
ELBOW, 4" 90 DEG., SA 234        NIA            NIA            N/A            N/A        N/A    Replaced ELBOW, 4"    DUBOSE NATL        HEAT  &#xb9;                    UTC 381319 90 DEG., SA 234      ENERGY          N87038          N/A          RIR 30129    1995  Replacement        NO ELBOW, 4" 45 DEG. SA 234
              ~            N/A            N/A                            NIA        N/A    Replaced        NO ELBOW, 4"    DUBOSE NA'PL      HEAT  &#xb9;                    UTC 381320 45 DEG. SA 234
              ~          ENERGY          N75134          N/A          RIR 30129    199s  Replacement BOLT- SA193      ALLIEDNUT        HEAT  &#xb9;                      UTC 347675 5/8"-11UNC2A      AND BOLT        88147-GP          N/A        RIR 1J-1421    1994  Replacement        NO BOLT- SA193      ALLIEDNUT        HEAT &#xb9;                      UTC 374492 5/8"-11UNC2A      AND BOLT        8078593          N/A          RIR 24742    1995  Replacement        NO NUT-SA 194    ALLIEDNUT        HEAT &#xb9;                      UTC 375497 5/8"-11UNC2B      AND BOLT          L63812          NIA          RIR 25731    199s  Replacement        NO BOLT- SA193      ALLIED NUT        HEAT  &#xb9;                    UTC 373936 1 1/4"-8UNC2A      AND BOLT        8894177          N/A          RIR 24401    199s  Replacement        NO NUT-SA 194    ALLIEDNUT        HEAT  &#xb9;                    UTC 374489 1 1/4"-8UN2B    AND BOLT          151593          N/A          RIR 24742    1995  Replacement        NO
 
PSL-1, NIS-2TRACKING NO. S            L-2          63 FORM NIS-2 OIVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 01/18/96 P. O. Box 529100                              Sheet:  I          of  3 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO &#xb9;: 8218
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95012801-01 6501 South  Hwy. AIA                          WCD &#xb9;: 0187 Jensen Beach,  FL 34957
: 4. (a) Identification of System        INTAKECOOLING WATER                        Type Code Symbol Stamp N/A (b) Component Identification        LINE I-364iV-16                                        Expiration Date N/A (Mark Number)            LINE I-30-CiV-2l (c) Code  Class:            3
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year Replaced          ASME Code Component or      Manufacturer Serial or Heat          Board      Identification Built Repaired or        Stamped Material                              No.            No.                              Replacement      (Y or N)
FLANGE, SA 105 4", WELD NECK            N/A              N/A            NIA            N/A        NIA    Replaced          NO FLANGE, SA 105      TIOGA PIPE        HEAT  &#xb9;                    UTC 374412 4", WELD NECK      SUPPLY CO.          8860283          NIA          RIR 24917    1995  REPLACEMENT          NO FLANGE, SA 105 4", SLIP ON            N/A              N/A            NIA            N/A        NIA    Replaced          NO FLANGE, SA 105      TIOGA PIPE        HEAT  &#xb9;                    UTC 378524 4", SLIP ON      SUPPLY CO.          8861721          NIA          RIR 27818    1995 REPLACEMENT            NO PIPE, 4"        TIOGA PIPE        HEAT &#xb9;                      UTC 382058 SA106          SUPPLY CO.          N87139          N/A        RIR2K-0032 1994 REPLACEMENT                NO
: 7. DESCRIPTION OF WORK:                PUP" PIECE ADDED TO EASE FIT UP OF FLANGE. BOLTING AND FLANGES, WHICH WERE WORN, DUE TO NORMALWEAR AND TEAR WERE REPLACED PER FPL DIRECTION.
: 8. Test Conducted:          Hydrostatic [X]                Pneumatic  []                  Nominal Operating Pressure (ISLT) [ X]
Other. VT1    []        VT2[X]          VT3[]                ISLTaYS. PSIG      Test Temp.        sYsTEM F HOLDTIME HYDRO-10MIN. O100PSIG                      Hold Time      IsLT-4 HRs
 
PSL-1, NIS-2 TRACKING NO. S L 8 -                63 FORM NIS-2          (Back)                  Sheet    2  of
: 9. Remarks            IsLTwAs sATlsFAGTQRILY PERFQRMED FoR THE FLANGED coNNEGTIQNs.
HUDROSTATIC TEST WAS SATISFACTORILY PERFORMED ON THE WELDED JOINTS.
: 10. Inspection Report Numbers:            M95-198 AND M95-309 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this          [  ] Repair      [ X) Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorizati No N/A Signed                                                                        Date wners or Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                                        ~r>~l Inspectors Signature                                National Board, State, Providence and Endorsements Date                                                    <9~4
 
PSL-2, NIS-2TRACKING NO. S            L-2          65 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power & Light Co.                      Date: 12/27/95 P. O. Box 529100                            Sheet:    I          of 2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.O.  &#xb9;: N/A 6501 South Hwy. AIA                          PCM&#xb9;: N/A Jensen Beach, FL 34957                    NPWO    &#xb9;: 7709
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95010521-1 A 6501 South Hwy. A1A                            WCD &#xb9;: N/A Jensen Beach,  FL 34957
: 4. (a) Identification of System        STEAM GENERATOR                            Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        2B COLDLEG HANDHOLE                                    Expiration Date N/A (Mark Number)
(c) Code Class:    I
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable Edition of Section XI for Repairs  and  Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year      Replaced    ASME Code Component or      Manufacturer    Serial  or Heat    Board    Identification Built Repaired or          Stamped Material                              No.          No.                              Replacement      (Yor N)
HELI-COIL                            HEAT  &#xb9;                    UTC 385001 SA 479            ABB/CE            51892          N/A      RIR 3AF-2278    1992      REPAIRED
: 7. Description Of Work:                  ENGINEERING PROCEEDURE 'EP-9448-CSE91-2131 ADDRESSES THE REPAIR OF STUD HOLES WITH THE USE OF HELICOIL INSERTS.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) [X ]
Other: VT1    []        VT2[X]            VT 3 []          sYsTEM      PSIG      Test Temp.      sYBTEM      F Hold Time 4 HDURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          65 FORM NIS-2            (Back)                  Sheet  2    of
: 9. Remarks            AN IsLT wAs sUGGEssFULLY PERFQRMED AND wlTNEssED BY A CERTIFIED VT-2 Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95495 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this            [X ) Repair        [ ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorizatio No N/A Signed                                                                        Date Brs or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the OwneCs Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind adsing from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date                                                    19~(
 
PSL-1, NIS-2 TRACKING NO.              SL-2                    Fp FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section XI
: 1. Owner:                          Florida Power & Light Co.                Date:      11/29/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                Florida Power & Light Co.                            2389  'WO&#xb9;:
6501 South Hwy. A1A WO &#xb9;:      95001683-01 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification    of System:      Safety Injection Type Code Symbol Stamp      N/A HCV-3657 Authorization No.          N/A (b) Component Identification:                                                                        Expiration Date            N/A (Mark Number)
(c) Code Class:        2
    ) Applicable Construction Code and Addenda:              ASME Sect III 74 Ed./Sum 76Add            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer      National      Other          Year        Replaced      ASME Component            Manufacturer        Serial or Heat    Board                        Built      Repaired      Code or                                        No.        No. Identification                    or      Stamped Material                                                                                      Replacement PorN) a er    isc            ames urry                                                                    ep ace Shaft Assembly              Corp.                                        Gf CF8M a er    isc            ames uriy            ena    o                        351                    ep acement Shaft Assembly              Corp.              RKG-1                    Gr CF8M ange  tu s                aw                                              A 19                    ep ace 1  X8unc2A                                                                Gr 87 ange    u s              ova                eat o                          S    93                ep acement 1  X8unc2A                                  8090323                      Gr 87
: 7. Description of Work:            Replaced disc assembly and flange bolting    - >~+    P~PlcLrs-'d
                                      +g ~en+        lm~gc
: 8. Tests Conducted:            Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
Other. VT1            VT2          VT3                      psig    Test Temp.            'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORII NIS-2 (Back)                                      Sheet 2 of      2
: 9. Remarks:          A satisfactory inseivice leakage test was performed and witnessed by a VT-2 certiTied inspector.
: 10. Inspection Report Numbers:            MM95-1893 APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed  M        ner
                                ~a. P~ Gum- t~f Ownei's Designee, Title CaIe IOgu    S~C    Ig~T CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
                                          /  Commissions inspector's Signat'e                                      National Board, State, Providence and Endorsements Date                                19 WJ
 
                                    ~ 0      ~
                                                                                    ~      I              ~  ~      ~    ~    ~    ~
                                                              ~    0  ~  ~  ~  ~        ~      ~  l ~  \
                        ~        ~      .
                                          ~    ~    ~            ~        ~  ~  ~        ~              ~ ~  '      ~
                                                        ~          ~          ~ ~          ~              \  ~
P        ~ ~
I        ~                          ~      I
                      ~      ~      ~            ~                                  ~        I  ~    I                        ~    ~ I
    ~  ~
                                                                                ~      ~  II                                                ~ ~
  ~      ~    P ~ ~
      ~    ~                  ~      ~                    ~      II  ~
                                            ~                                                                                      ~  ~
      ~ ~    ~                    ~ ~          ~        ~ ~                          ~  ~                                ~ ~
~ ~
                                                                                                                    ~  ~
 
FORM N 2(back)
CERTIFICATE OF DESIGN NY Design specifications certified by T.L. Kettles                                                P. E. state                Rag. no.
N/A
                                                                                                                                          '/A N/A                                                    P. F state                  Reg. no.
Destgn report certltied by CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made In this report are correct and that this phase) conform to the rules ot construction ot the ASME Code, Section III.
October 27, 1993 ASME Certificate of Authorization no.                                                        Expires
        ~          F2.                Neles-Jamesbury,              Inc.
Oate                        Name
                                                  ~  cervlaeco saasen Signed ianhariaed yreserasim)
I CERTIFICATE OF SHOP INSPECTION I, the underslpned, holdinp a valid commission Issued by the National Board ot Boiler and Pressure Vessel Inspectors and the state or pro.
nd employed by protection Inca oiMassachuset ts Mutua 1 of          oorj  MA          have Inspected these Items described In this data report on best of my knowledge and belief, lhe Certificate Holder has fabricated these parts or appurt Section tli. Each part listed has been authorized for stamping on!he dale shown above.
By ~ Ipnlng this certilicate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment scribed In this data report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal Injury or rty damage or loss ol any tdnd arlslnp from or co              with this Inspection.      pactory Mutual Systems Gate                                                                                    Commissions
                                                ~hOHCKt IhiOOCIN)                                    y4ark ed. ImL endorsemontn slate w pew. end no)
 
PSL-1, NIS-2 TRACKING NO.            SL-2                                              FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                Date:      11/28/95 P.O. Box 529100                          Sheet:    I  of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM &#xb9;: 158-295M 3, Work Performed By.            Florida Power & Light Co.                IWO&#xb9;:      3613 6501 South Hwy. A1A WO &#xb9;:      95002158 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:      N/A
: 4. (a) Identification  of System:      Containment Spray Type Code Symbol Stamp          N/A FCV-07-1A Authorization No.              N/A (b) Component Identification:                                                                    Expiration Date                N/A (Mark Number)
(c) Code Class:    2 a) Applicable Construction Code and Addenda:          ASME Section III 74 Edition / No Add. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other        Year      Replaced            ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                      No.        No. Identification                                  Stamped OI'eplacement Material (Y or N) ae                    a ves                                          4                    ep ace 300 Ib/8                                                            Gr 316 ate                ooper            Sea    o                        240        9 4      ep acement 300 Ib/8            Industries          K272620                    Gr 316
: 7. Description of Work:      Replaced gate due to erosion
: 8. Tests Conducted:        Hydrostatic              Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2            VT3                    psig  Test Temp.                  'F
 
PSL-2, NIS-2 TRACKING NO.              SL-2                                                  FORM NIS-2 (Back)                                        Sheet 2 of      2 t.
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        hii ~ q g Q 7g APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Auth rization No.: N/A Signed r r Owner's Designee, Title pv  -    IS            Date  ~~ 19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components descdbed in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2TRACKING NO. S            L-2            68 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL
: 1. Owner                                Florida Power & Light Co.                      Date: 12/27/95 P. O. Box 529100                              Sheet:  I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.O. f/: N/A 6501 South Hwy. AIA                          PCM&#xb9;: N/A Jensen Beach,  FL 34957                  NPWO f/: 7709
: 3. Work Performed By:                    Florida Power  & Light Co.                    WO jj: 95010521-1A    & 01 6501 South Hwy. A1A                            WCD f/: N/A Jensen Beach,  FL 34957
: 4. (a) Identification of System          STEAM GENERATOR                          Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification          28 COLDLEG HANDHOLE BOLTING                          Expiration Date N/A (Mark Number)
(c) Code Class:      1
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification  of Components  Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National        Other      Year      Replaced      ASME Code Component or        Manufacturer Serial or Heat        Board      Identification Built Repaired or          Stamped Material                                No.          No.                              Replacement        (Y or N)
STUD - SA193                            HEAT  &#xb9;                    UTC 314658 1"-8UNC2A X 6"        ABB/CE              85689          N/A        RIR 1H-1524    1992  Replacement          NO STUD - SA1 93      COMBUSTION          HEAT  &#xb9;                    UTC 314658 1"-8UNC2A X 6"      ENGINEERING          85689          N/A        RIR 1H-2360    1983  Replacement          NO NUT- SA193        COMBUSTION          HEAT&#xb9;                      UTC 314662 1"-8UNC        ENGINEERING          215272          N/A        RIR 1H-2360    1983  Replacement          NO
: 7. Description Of Work:                    BOLTING MATERIALREPLACED BECAUSE OF ONE BROKEN STUD AND NORMALWEAR AND TEAR ON THREADS OF ANOTHER
: 8. Test Conducted:            Hydrostatic [ ]              Pneumatic  f]                  Nominal Operating Pressure (ISLT) [X ]
Other: VT1      []        VT2[X]          VT 3  []        SYSTEM      PSIG      Test Temp.        sysTEM    F Hold Time 4 HQURs
 
PSL-1, NIS-2 TRACKING NO. S L 8 -                68 FORM NIS-2            (Back)                  Sheet    2  of
: 9. Remarks            AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95<95 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate      of    Compliance We certify that the statements made in the report are correct and this          [  ] Repair      [X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorizatio No N/A Signed                                                                        Date            Z  ~,      19~&
ers or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle f/8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO. S L 8 -                69 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power & Light Co.                      Date: 12/27/95 P. O. Box 529100                            Sheet:    1          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.O.  &#xb9;: N/A 6501 South Hwy. A1A                          PCM&#xb9;: N/A Jensen Beach,  FL 34957                  NPWO      &#xb9;: 7709
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95010526-01 6501 South Hwy. A1A                            WCD &#xb9;: N/A Jensen Beach, FL 34957
: 4. (a) Identification of System        STEAM GENERATOR                            Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        2A HOTLEG HANDHOLE BOLTING                            Expiration Date N/A (Mark Number)
(c) Code Class:    1
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year Replaced          ASME Code Component or      Manufacturer Serial or Heat        Board      Identification Built Repaired or          Stamped Material                              No.          No.                              Replacement      (Y or N)
NUT- SA193        COMBUSTION          HEAT  &#xb9;                    UTC 314662 1"-8UNC        ENGINEERING          215272          N/A        RIR 1H-2360    1983    Replacement STUD - SA193      COMBUSTION          HEAT &#xb9;                    UTC 314658 1"-8UNC2A X 6"      ENGINEERING          85689          N/A        RIR 1H-2360    1983    Replacement        NO
: 7. Description Of Work:                  BOLTING MATERIALREPLACED BECAUSE OF WORN THREADS DUE TO NORMALWEAR AND TEAR.
: 8. Test Conducted:          Hydrostatic [ ]              Pneumatic  []                  Nominal Operating Pressure (ISLT) [X ]
Other: VT1    []        VT2[X]          VT 3 []          sYsTEM      PSIG      Test Temp.      sYsTEM      F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          69 FORM NIS-2          (Back)                  Sheet  2    of
: 9. Remarks            AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95-497 APPLICABLE MANUFACTVREIrsDATAREPORTS To BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [ X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Author tion No N/A Signed Owners or Owners Designee, Title Date    /Z      >7,          19  9'5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board      of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cyde &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-2, NtS-2TRACKtNG NO.                SL-2        ~070 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F            ~
As Required by the Provisions of the ASME Code Section XI
: l. Owner:                        Florida Power & Light Co.              Date:      1/22/96 P.O. Box 529100                        Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucio Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA JcnsenBcach, FL 34957                    PCM&#xb9;: NA 3    Work Performed    By'lorida Power & Light Co.                        PWO&#xb9;: 4894 6501 South Hwy. A1A WO &#xb9;:      95025593 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:    N/A
: 4. (a) IdcnQication    of System:    Safety Injection Type Code Symbol Stamp      N/A V3217 Authorization No.          N/A (b) Component Identification:                                                                      Expiration Date            N/A (Mark Number)
(c) Code Class:          1 None a) Applicable Construction Code and Addenda: ASME SEC. III;1974 ED.; S74 ADDENDA Code Case:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National        Other          Year      Replaced        ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired        Code or                                      No.        No. Identification                    or          Stamped Material                                                                                    Replacement (Yor N)
DISC          WESTINGHOUSE            S/N-2025        NA      SA182 GR. F316      NA        Replaced DISC          WESTINGHOUSE            S/N 4499        NA      SA182 GR. F316      NA      Replacement BONNET NUTS              ALLIED              &#xb9; HT 500260        NA      SA 453 GR 660      NA      Replacement
: 7. Description of Work:      REPLACE DISC ASSEMBLY 8 BONNET NUTS DUE TO WEAR.
: 8. Tests Conducted:        Hydrostatic Other: VT1 X
                                                  ~      Pneumatic VT2 X      VT3 Nominal Operating Pressure (tSLT)
                                                                                    ~Psig          TestTemP.    ~'P    X
 
PSL-2, NIS-2 TRACKING NO.                SL-2C-          ~070 FORM NIS-2 (Back)                                      Sheet 2 of 2
: 9. Remarks:          A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT CERTIFIED INSPECTOR.
CUING.)
: 10. Inspection Report Numbers:            MM95-1692 & 1694 (VT 1)
I7I7AR4      - IS.S APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Own
                                  ~    PL/i.fat~
Owner's Designee, Title gVPV,      tSI        Date    Atl otk        19  l4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719    FL Com      &#xb9;60 inspector's Signature                                    National Board, State, Providence and Endorsernents Date
 
PSL-1, NtS-2TRACKtNG NO.              SL-2        ~871 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                Date:      11/14/95 P.O. Box 529100                          Slleet;    1, of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    5342 Jensen Beach, FL 34957                    PCM    &#xb9;: NA
: 3. Work Performed By:          Florida Power & Light Co.                PWO    &#xb9;:  5324 6501 South Hwy. A1A WO &#xb9;:      95031268 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:    N/A
: 4. (a)  IdenQicationofsystem:        Safety Injection Type Code Symbol Stamp      N/A Authorization No.          N/A (b) Component V3225 Identification:                                                                    Expiration Date            N/A (Mark Number)
(c) Code Class:    1 None
    )  Applicable Construction Code and Addenda: ASME SEcr III 1980 Eomoii / W80 ADD Code Case:
(b) Applicablc Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National        Other          Year    Replaced        ASME Component          Manufacturer      Serial or Heat  Board                        Built    Repaired        Code or                                      No.        No. Identification                  or          Stamped Material                                                                                  Replacement (Yor N)
Weld Repair              NA                Ht No        NA        P8To P8          NA      Repaired Bonnet                              CT6100 0434              SA 182 TR316
: 7. Description of Work:    Weld repair bonnet pressure seal area.
: 8. Tests Conducted:      Hydrostatic Other  VT1
                                                ~      Pneumatic VT2 X        VT3              ~psig        Test Temp.    ~'P Nominat Operating Pressure (tSLT)      X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~071 FORM NIS-2 (Back)                                        'heet    2 of  2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbeis:          g$  Wg'.j 7 g8'S APPLICABLE MANUFACTURES OATA REPORTS To BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this                      X Repair        Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed OwiIer or      er's Designee, Title S~PV    - LS)            Date~llN      t.,    19  0L2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719    FL Com      440-~ p tnspectol's Signature                                        National Board, State, Providence and Endorsements
 
PSL-1, NIS-2 TRACKING NO.              SL-2                                                FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                            Florida Power & Light Co.                Date:      11/20/95 P.O. Box 529100                          Sheet:      I  of Miami, FL 33152 Unit:      2
: 2. Plant:                            St;-Lucie Nuclear Plant 6501 South Hwy. AIA                      P.o.f/:    NA
                                    'ensen    Beach, FL 34957                  PCM/f: NA
: 3. Work Performed By:                Florida Power & Light Co.                PWO/f: 1118 6501 South Hwy. A IA WO f/:      94015104 Jensen Beach, FL 34957 CWO      k  NA        Process Sheet:  N/A
: 4. (a) Identification      of System:      Feedwater Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component                        MV09-11 Expiration Date          N/A Identification:
(Mark Number)
(c) Code Class:        2
    ) Applicable Construction Code and Addenda: ASME SEcT III 1974 EomoN No AooEttoA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification      of Components    Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer    National        Other          Year      Replaced      ASME Component            Manufacturer        Serial or Heat  Board                          Built    Repaired      Code No.        No.      Identification                  or        Stamped oi'aterial                                                                                  Replacement (Yor N) ave ug                                                                                              ep ace 4" /600 Ib                                                              TP 316 ave ug                    nc or                  0                        4 9          9 0    ep acement 4" /600 Ib                Darling        0000379151                    TP 316
: 7. Description of Work:            Replaced plug due to damaged seating surface
: 8. Tests Conducted:            Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
VT2          VT3                              Test Temp.            'F Other: VT1                                                  psig
 
PSL-2, NIS-2 TRACKING NO.                  SL-2                                                  FORM NIS-2 (Back)                                          Sheet 2 of    2
: 9. Remarks          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:      'r'<%giO Z 4O~
APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                            +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization t No.: N/A Signed                            KP PmmiSOPV  ls'I                      Date ILDV QD          19  RE ne    Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Ownei's Report during operating cycle            &  starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements
 
PSL-1, NtS-2 TRACKING NO.              SL-2      ~374
                                ~            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.              Date:    12/12/95 P.O. Box 529100                        Sheet:      1 of  2 Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucic Nuclear Plant 6501 South Hwy. A1A                  P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power & Light Co.              PWO&#xb9;: 3640 6501 South Hwy. A1A Wo &#xb9;.      94025096 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A 4., (a) Identification    of System:    Feedwater Type Code Symbol Stamp    N/A V09157 Authorization No.        N/A (b) Component Identification:                    4'Aux. Fd Wtr.                                  Expiration Date          N/A (Mark Number)          CHECK VLV
      '(c) Code Class:          2
      ) Applicable Construction Code and Addenda:        ASME SEC. III; CL 2 1974 ED.-'76 ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other        Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                      No.        No. Identification                  of        Stamped Material                                                                                    Replacement (Yor N)
DISC (FOR              CONTROL          S/N: M336830      NA      SA 216; GR.      NA      Replacement VALVE) 4'HECK COMPONENTS                                        WCB 3/4'-10 UNC 2A      ALLIEDNUT & BOL        HT&#xb9; 88147        NA      SA 193; GR 87      NA      Replacement ALLTHREAD 3/4 -10 UNC 28      ALLIEDNUT & BOL      HT&#xb9;E04277NA        NA      SA 194; GR 2H      NA      Replacement HEAVY HEX NUTS
: 7. Description of Work:      REPLACE DISC DUE TO WEAR.
REPLACE BOLTING DUE TO CORROSION
: 3. Tests Conducted:        Hydrostatic Other: VT1
                                                    ~      Pneumatic VT2 X        VT3            ~psig          TestTemp.    ~'P Nominal Operating Pressure (tSLT)    X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~074 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:          A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:          ivy tv'    4 - V lg APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                      SR                upv. IS(                  DaIe~EC. I'8          19~1 r or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL        Com&#xb9;60 Inspector's Signature                                        National Board, State, Providence and Endorsements Date
 
PSL-2, NIS-2 TRACKING NO.              SL-2      075 F        g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power  k Light Co.              Date:      1/22/96 P.O. Box 529100                        Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA JensenBeach, FL 34957                    PCM&#xb9;: NA 3  Work Performed        By'lorida Power k Light Co.                        PWO&#xb9;: 3640 6501 South Hwy. A1A WO &#xb9;:      95003428 JensenBeach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification of System:          Safety Injection Type Code Symbol Stamp      N/A V3414                                            Authorization No.        N/A (b) Component Identification:                                                                        Expiration Date            N/A (Mark Number)
(c) Code Class:          2
    )  Applicable Construction Code and Addenda: ASME SEC. III; 1971 ED.; S74 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer    National        Other          Year      Replaced      ASME Component            Manufacturer        Serial or Heat  Board                        Built    Repaired      Code No.        No.      Identification                    or      Stamped oi'aterial Replacement (Yor N)
DISC ASSEMBLY          TARGET ROCK              NA          NA      SA479 TQ47/348      1976      Replaced DISC ASSEMBLY          TARGET ROCK                            NA      SA479 T-347/348      NA      Replacement
: 7. Description of Work:        REPLACE DISC DUE TO WEAR
: 8. Tests Conducted:          Hydrostatic Other. VT1
                                                    ~      Pneumatic VT2 X      VTS Nominat Operating Pressure (ISLT)
                                                                                      ~psig          TestTemp.    ~'F  X
 
PSL-2, NIS-2 TRACKING NO.                SL-2        ~070 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:              MM95-2351 APPUCABLE MANUFAC1URES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed                L  +~    PL&      ZDI ~                          Date  ~aeA    ~2, 19~4 0      or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
ED        Commissions              NB7719 FL      Com&#xb9;60 inspector's Signature                                      National Board, State, Providence and Endorsements Date                    94, 19~
 
PSL-2, NIS-2 TRACKING NO. S L            8-        76 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS FPL                              As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/19/95 P. O. Box 529100                              Sheet:  I          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                      P.O.  &#xb9;: N/A 6501 South Hwy. A1A                          PCM&#xb9;: N/A Jensen Beach,  FL 34957                    NPWO    &#xb9;: 8220
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95013790-1A 6501 South Hwy. A1A                            WCD &#xb9;: N/A Jensen Beach,  FL 34957
: 4. (a) Identification of System        SAFETY INJECTION                            Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        SUPPORT SI4201-7760                                    Expiration Date N/A (Mark Number)            SNUBBER 2467 (c) Code Class:    1
: 5. (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                      N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other      Year      Replaced      ASME Code Component or        Manufacturer Serial or Heat        Board      Identification Built Repaired or        Stamped Material                              No.          No.                                Replacement      (Y or N)
      'BRACKET, PT&#xb9;                          SERIAL  &#xb9; BEA22-11A-10          NAVCO            5623-30          NIA        UTC 381536      1983  REPACEMENT
: 7. DESCRIPTION OF WORK:                  AS FOUND CONDITION DID NOT MATCH DWG. INSTALL NEW PART PER DWG. & AS BUILDAS REQUIRED.
: 8. Test Conducted:          Hydrostatic [ ]              Pneumatic    []                  Nominal Operating Pressure (ISLT) f ]
Other. VT1      []        VT2[]            VT3 [X]                        PSIG      Test Temp.                  F Hold Time
 
PSL-1, NIS-2TRACKING NO. S            L-2                  76 FORM NIS-2          (Back)                  Sheet  2  of
: 9. Remarks            A FINALVISUALEXAM WAS PERFORMED BY A VT-3 CERTIFIED INSPECTOR      .
: 10. Inspection Report Numbers:            95-PSL-2067 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHE0 Certificate      of  Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [X ] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:                N/A Certificate of Authorization No N/A Date    )Elf~I,              19 Owners or Own    s Desi    ee, Title OF INSERVICE INSPECTION                                'ERTIFICATE I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida        and employed by  Arkwright  Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle f/8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signa ure                                National Board, State, Providence and Endorsements Date
 
PSL.2, NIS-2 TRACKING NO                SL-2.8.      ~077 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                          Florida Power  & Light Co.              Date:      3/8/96 P.O. Box 529100                          Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                              St. Lucic Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM    &#xb9;: NA
: 3. Work Performed By:                  Florida Power  & Light Co.              PWO    &#xb9;:  5377 6501 South Hwy. A1A WO  &#xb9;:    95031723 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification of System:            Reactor Coolant Type Code Symbol Stamp      N/A Authorization No,        N/A (b) Component                          V1234 Identification:                                                                          Expiration Date          N/A (Mark Number)
(c) Code Class:            1 a) Applicable Construction Code and Addenda: ASME SECTION III; 71'D.-W
                                                                                              '73 ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification        of Components Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer    National      Other          Year    'eplaced        ASME Component              Manufacturer      Serial or Heat  Board                        Built      Repaired      Code No.        No. Identification                    or      Stamped oi'aterial                                                                                Replacement (Yor N)
STUDS                ALLIED            52825-DF                  SA 193,  Bj        NA      Replacement 7/8'-9 UN C 2A NUTS                ALLIED            NU312565          NA      SA 194 GR 2H        NA      Replacement 7/8'9 UNC 2B
: 7. Description of Work:        REPLACE BLIND FLANGE BOLTING DOWNSTREAM OF 2 DRAIN VALVE DUE TO HEAVY CORROSION .
: 8. Tests Conducted:        Hydrostatic Other;  VTI X
                                                      ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure (ISLTI
                                                                                          ~[Pstg        Test Temp.    ~'F  X
 
PSL-2, NIS-2 TRACKING NO.                SL              ~077 FORM NIS-2 (Back)                                      Sheet 2 of 2
: 9. Remarks:          A SATISFACTORY INSPECTION OF THE NEW BOLTING (VT 1) AND A'N FOR LEAKAGE (VT 2) WAS PERFORMED.                                        'NSPECTIONN
: 10. Inspection Report Numbers:              MM95-1 771 &
MM95-2484 APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed            As er or
                                <<a        p~ S~e~
ai's Designee, Title IS i        CaIe  > I 27 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Co.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719    FL  Com&#xb9;329 Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2TI2ACKING NO.              SL-2      ~078 g          FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                    Date:      12/8/95 P.O. Box 529100                              Sheet:
Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                          P.O.&#xb9;:      NA Jensen Beach, FL 34957                      PCM &#xb9;: NA
: 3. Work Performed By:            Florida Power    & Light Co.                PWO&#xb9;: 91-8220 6501 South Hwy. A1A WO &#xb9;:        VARIOUS Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification  of System      SNUBBERS Type Code Symbol Stamp    N/A 2-039,2-046                                          Authorization No.        N/A (b) Component Identification:                  2-066,2-067                                          Expiration Date          N/A (Mark Number)        2 p84 2 p88 (c) Code Class:        ALL    2 125, 2 15p 2-156 a) Applicable Construction Code and Addenda:            ASME SEC. III; 1977 ED THRU '79 ADD.
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer      National        Other          Year    Replaced      ASME Component        Manufacturer        Serial or Heat    Board                          Built    Repaired      Code of                                        No.        No.      Identification                    of      Stamped Material                                                                                      Replacement (Yor N)
PSA 1/4 SNUBBER:          PACIFIC        S/N 38499 (OLD)        NA          WO&#xb9;            NA      Replacement 2439            SCIENTIFIC      S/N 38503 (NEW)                  9501375841 PSA 1/4 SNUBBER:          PACIFIC        S/N 11832 (OLD)        NA          WO&#xb9;            NA      Replacement 2446            SCIENTIFIC      S/N 38510(NEW)                  9501378541 PSA 10 SNUBBER:          PACIFIC        S/N 17848 (OLD)        NA          WO&#xb9;            NA      Replacement 2-066            SCIENTIFIC      S/N 16610 (NEW)                  9501378741 PSA 10 SNUBBER:      PAC. SCIENTIC        s/N 12848 IQLo)            WO&#xb9; 950137904                RepIacement s/N 81256/32 INEw) 2467          LISEGA 3062 RF1                            NA'A PSA 3 SNUBBER            PACIFIC        S/N 29504 (OLD)                    WO&#xb9;                    RepIacement 2484            SCIENTIFIC      S/N 24747 (NEW)                  9501371541 PSA  1 SNUBBER          PACIFIC        S/N 7419 (OLD)                    WO&#xb9;            NA      Replacement 2-088            SCIENTIFIC      S/N 12289 (NEW)                  9501378841
: 7. Description of Work:      REPLACE SNUBBERS DUE TO TEST FAILURES. REFER TO INDIVIDUALWORK ORDERS FOR SPECIFIC DETAILS.                                          s
: 8. Tests Conducted:      Hydrostatic Other: VT1
                                                    ~    VT2 Pneumatic VT3 X            ~psig          TestTemp.    ~'F Nominal Operating Pressure (ISLT)
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~078 FORM NIS-2 (Back)                                        Sheet 2 of 3
: 9. Remarks:        A POST INSTALLLTIONVT 3 WAS PERFORMED FOR ALL SNUBBERS.
INFORMATION RECORDED ON INDIVIDUALVT 3 INSPECTION REPORTS ON FILE.
: 10. Inspection Report Numbers:              VARIOUS.
APPLiCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Signed        A Ow
                          '~
Certificate of Authorization No.: N/A
                                      ~Citii @Pt/- IXI r or Owner's Designee, Title Date  ~IS'9~9 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719 FL Com          &#xb9;60 lnspectoi's Signat re                                        National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.          SL-2    ~078 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI PL                                SUPPLEMENTAL SHEET
: 1. Owner:                  Florida Power & Light Co.                Date:  12/8/95 P.O. Box 529100 Mami, FL 33152                    Sheet:          3 of  3
: 2. Plant:                  St. Lucie Plant                  Unit &#xb9;:          2 6501 South Hwy. A1A Jensen Beach, FL 34957            P.O.  &#xb9;:            NA
: 3. Work Performed By:                      k Florida Power Light Co.            PCM &#xb9;:        NA 6501 South Hwy. A1A
: 6. Identification of Components Repaired or Replaced and Replacement Components:
National                            Replaced    ASME Name of            Name of          Manufacturer                    Other        Year Serial or Heat    Board                              Repaired      Code Component          Manufacturer                                    Identification  Built No.        No.                                  or      Stamped Replacement  (Y or N)
PSA 1/4 SNUBBER          PACIFIC        S/N 37659 (OLD)    NA            WOO          NA  REPLACEMENT 2-125          SCIENTIFIC      S/N 38489 (NEW)              9501376941 PSA 1  SNUBBER          PACIFIC        S/N 14880 (OLD)    NA            WOII        NA  REPLACEMENT 2-150          SCIENTIFIC      S/N 26002 (NEW)              95013771  ZI A1 SNUBBER            PACIFIC        S/N 12790 (OLD)    NA            Wot/        NA  REPLACEMENT 2-156          SCIENTIFIC      S/N 26008 (NEW)              9501375941
 
PSL-1, NIS-2 TRACKING NO.              SL-2      ~gyp
                                      ~            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                            Florida Power & Light Co.              Date:      1/2/96 P.O. Box 529100                        Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                                St. Lucic Nuclear Plant 6501 South Hwy. AIA                  P.O.&#xb9;:    NA Jensen Beach, FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:                  Florida Power & Light Co.              PWO    &#xb9;:
6501 South Hwy. A1A WO &#xb9;:      94025103 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:  N/A
: 4. (a) Identification          of System:    Main Steam Type Code Symbol Stamp    N/A MV-08-19B                                        Authorization No.        N/A (b) Component Identification:                                                                          Expiration Date          N/A (Mark Number)
(c) Code Class:              2
      )  Applicable Construction Code and Addenda: ASME SEC. III; 1980 ED. NO ADDENDA Code Case: None (b) Applicablc Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of                Name of          Manufacturer    National      Other          Year    Replaced      ASME Component              Manufacturer        Serial or Heat  Board                        Built    Repaired      Code or                                          No.        No. Identification                    of      Stamped Material                                                                                      Replacement (Y or N)
PLUG ASSEMBLY              PACIFIC VALVE              NA          NA      SA 182 GR F11      1980      Rep'laced 10' 12'LUG ASSEMBLY              CONTROL            S/N 360270        NA      SA 182 GR F11      1992    Replacement 10 X12                COMPONENTS BONNET STUDS                  CONTROL              &#xb9; HT 231 50B        NA      SA 193 GR B7        NA    Replacement 1  1/4 N UN X 7 1/4        COMPONENTS BONNET NUT              NOVA MACHINE            &#xb9; HT 8099455        NA      SA 194 GR 2H        NA    Replacement 1 1/4 -8 UN 2B
: 7. Description of Work:          REPLACE PLUG ASSEMBLY DUE TO STEAM CUTTING. STUDS 8 NUTS REPLACED DUE TO CORROSION.
: 8. Tests Conducted:            Hydrostatic Other: VT1
                                                        ~      Pneumatic VT2 X        VT8 Nominal Operating Pressure(ISLTI
                                                                                            ~pstg        TestTemp.    ~'P    X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~079 FORM NIS-2 (Back)                                          Sheet 2 of 2
: 9. Remarks:          A SATISFACTORY INSPECTION FOR LEAKGE WAS PERFORMED AND WITNESSED BY A VT 2 INSPECTOR.
I
: 10. Inspection Report Numbers:              MM95      1777(VTI}              KR&          (  L 6~i )
APPLICAB(.E MANUFACTuRES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair    X  Replacement conforms to the rules of the ASME Code, Section XI.
i Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Ow    r or Own    Designee, Title Cate  ~I    ~, 19~4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition no addenda.
                                                ~
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
C'57                              Commissions                NB7719 FL Com          &#xb9; 60 Inspecto Vs Signature                                        National Board, State. Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.                SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                          Florida Power & Light Co.                Date:      12/1/95 P.O. Box 529100                          Sheet:      I of    3 Miami, FL 33152 Unit:
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P,O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                Florida Power & Light Co.                PWO&#xb9;: 3572 6501 South Hwy. A1A WO &#xb9;:        95001867 Jensen Beach, FL 34957 CWO      &#xb9;: NA          Process Sheet:  N/A
: 4. (a) IdentificationofSystem:            ComponentCooling Water Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component                        SS-21-1B Identification:
Expiration Date          N/A (Mark Number)
(c) Code Class:    3 ASME Sect III 1989 Ed/No Add              Code Case: None
      ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of            Manufacturer    National        Other          Year      Replaced      ASME Component          Manufacturer          Serial or Heat  Board                          Built      Repaired      Code or                                        No.        No.      Identification                    of        Stamped Material                                                                                        Replacement (Y or N) tu      over              um                                                                        ep ace 1"-Sunc x 6'          Industries                                        Gr B7 Cover              ova                eat o                          93                  Rep acement 1  -Sunc x 6          Machine              8090323                      Gr B7 ut Cover                um                                                94                      ep ace 1 -Sunc            Industries                                        Gr2H ut    over          he      ut            eat o                          9                    ep acement 1'-8unc                Bolt              090309                      Gr 2H fT'i%9%1                    urn                              A                  3                    ep ace 3/4  x10uncx51/2          Industries                                        Gr B7 ova                eat o                          93                    ep acement 3/4 x 10unc x 5 1/2        Machine              8078372                      Gr B7
: 7. Description of Work:        Replaced strainer cover bolting and handhole bolting due to corrosion.
: 8. Tests Conducted:          Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2~        VT3                        psig    Test Temp.              'F
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                    FORM NIS-2 (Back)                                          Sheet 2 of    3
: 9. Remarks:          A satisfactory Inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:
APPLICABLE MANUFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                              +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner      nei's Designee, Title UPV    (s(        Date~, 19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors and the    State  or Providence  of Florida  and employed  by Factory  Mutual  Engrg Assoc.
have inspected    the components    described  in  this Owner's Report during  operating  cycle  ff8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions inspector's Signature                                        National Board, State, Providence and Endorsements Date            Z- %'
 
PSL-1, NIS-2 TRACKING NO.          SL-2                                    FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F PL                                    SUPPLEMENTAL SHEET
: 1. Owner:              Florida Power & Light Co.                  Date:  12/1/95 P.O. Box 529100 Miami, FL 33152                    Sheet:            3 of  3
: 2. Plant:                St. Lucie Plant                  Unit &#xb9;:              2 6501 South Hwy. A1A Jensen Beach, FL 34957              P.O. &#xb9;:              NA
: 3. Work Performed By: Florida Power & Light Co.                PCM &#xb9;:          NA 6501 South Hwy. A1A
: 6. Identification of Components  Repaired or Replaced and Replacement Components:
National                            Replaced      ASME Name of          Name of          Manufacturer                    Other        Year Board                              Repaired      Code Component          Manufacturer      Serial or Heat                Identification  Built No.        No.                                    or      Stamped Replacement  (Yor N) u    an  oe            urn                                                                  ep ace 3/4" x 10unc -2B      Industries                                        Gr2H u    an oe            ie    u              ea    o                                          ep acemen 3/4 x10unc-2B              Bolt            E04277                      Gr 2H
 
PSL-1, NIS-2 TRACKING NO.              SL                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                          Florida Power'    Light Co.            Date:      11/30/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                  Florida Power & Light Co.                PWO&#xb9;: 3640 6501 South Hwy. A1A WO &#xb9;:      95002733 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:        N/A
: 4. (a) IdentificationofSystem:              Component Cooling Water Type Code Symbol Stamp            N/A Authorization No.                N/A (b) Component                        V1 4147 Identification:                                                                          Expiration Date                N/A (Mark Number)
(c) Code Class:      3 a) Applicable Construction Code and Addenda:                    ASME Sect III 1974/ No Add            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification      of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer      National      Other          Year      Replaced            ASME Component            Manufacturer        Serial or Heat    Board                        Built    Repaired            Code of                                      No.          No. Identification                                    Stamped OI'eplacement Material (Y or N) ave                    ISS On                                                                  ep ace 20                                                                Gr WCB a  e            au    onroe              /                                        990      ep acement 20                                  894952%1                      Gr WCB ange      u          8  Saw                                                                        ep ace 1  1/8-8un 2A                                                              Gr 87 ange    tu            lie                eat o                              3                  ep acernent 1  1/8- Sun 2A                                52825                        Gr 87 ange    ut            s aw 1  1/8-8un 28                                                              Gr 2H ange      ut                                eat o                                                ep acement 1  1/8 - Sun 28                            152550 TR 053                    Gr 87
: 7. Description of Work:          Replaced valve due to seal damage and flange bolting due to corrosion.
: 8. Tests Conducted:            Hydrostatic              Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1              VT2          VT3                    psig    Test Temp.
 
PSL-2, NIS-2 TRACKING NO.                SL                                                  FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        tliriigQ  5 "Q.S p f APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                        c a2 PLeur          Uoov Isi              o,<<    IVov  Eo      Ig~q ner o  wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2TRACKING NO.              SL-2N-        082
                                ~          FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.                Date:      12/14/95 P.O. Box 529100                          Sheet:      1  of  2 Miam, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:      NA Jensen Beach, FL 34957                  PCM&#xb9;: NA 3    Work Performed By              Florida Power & Light Co.                PWO    &#xb9;:  5205 6501 South Hwy. A1A WO &#xb9;:      95029884 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:  N/A
: 4. (a) Identification of System:        Containment Purge Type Code Symbol Stamp      N/A FCV-25-36                                        Authorization No.          N/A (b) Component Identification:                                                                      Expiration Date            N/A (Mark Number)
(c) Code Class:          2 Applicable Construction Code and Addenda:            ASME Sect III 1977 Ed/ No add.          Code Case: None
    )
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat  Board                        Built,    Repaired      Code No.        No. Identification                    or      Stamped OI'aterial                                                                              Replacement (Yor N)
Wafer            Controlmatics            NF          NA      ASME SA 516                    Replaced
( Disc)                                                              Gr 70 Wafer            Controtmatics          Heat No        NA      ASME SA 516                  Replacement
( Disc)                                  8383726                    Gr 70
: 7. Description of Work:        Replaced disc due to wear
: 8. Tests Conducted:        Hydrostatic Other: VT1
                                                    ~  VT2 Pneumatic VT3 Nominal Operating Pressure itgLT)
                                                                                      ~psig          TestTemp.              'F
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        ~082 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A SATISFACTORY LOCAL LEAK RATE TEST WAS PERFORMED.
: 10. Inspection Report Numbers:              OP 2-'130051 APPLICABLE MANUFACTURE'S OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed      l    A date ner or 0 M Ptsan 8>PII-eVs Designee, Title ISI        Cate~IN                19  tI5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Piessure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719 FL      Com&#xb9;60 Inspector's Signature                                      National Board, State, Providence and Endorsements Date
 
0 PSL-1, NiS-2TRAOKtNG NO.              SL-2C-      ~083 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                                  Florida Power  & Light Co.              Date:      12/14/95 P.O. Box 529100                          Sheet:    1  of Miam, FL 33152 Unit:      2
: 2. Plant:                                  St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach,  FL 34957                  PCM&#xb9;: NA
: 3. Work Performed By:                      Florida Power  & Light Co.              PWO    &#xb9;:  1089 6501 South Hwy. A1A WO &#xb9;:      94025102 Jensen Beach, FL 34957 CWO &#xb9;:      NA        Process Sheet:  N/A
: 4. (a) Iden@ication              of System:    Main Steam Type Code Symbol Stamp    N/A MV-08-19A                                        Authorization No.        N/A (b) Component Identification:                                                                              Expiration Date          N/A (Mark Number)
(c)  Code        Class:        2 a) Applicable Construction Code and Addenda: ASME SEC. III 1980 ED; NO ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of                    Name of          Manufacturer    National        Other        Year      Replaced      ASME Component                  Manufacturer        Serial or Heat  Board                        Built    Repaired      Code No.        No. Identification                    or      Stamped ol'aterial                                                                                    Replacement (Yor N)
PLUG ASSEMBLY                  PACIFIC VALVE              NA          NA      SA 182 GR F-11      1980      Replaced PLUG ASSEMBLY                    CONTROL            SN&#xb9;: 360270                SA 182 GR F11      1992    Replacement COMPONENTS 1  1/4 N UN - 2B          ALLIEDNUT & BOL        HT&#xb9; E 97187      NA      SA194; GR2H          NA    Replacement BOONET NUT 1  1/4 W UN 2A            ALLIEDNUT & BOL        HT&#xb9; 62413        NA      SA 193; GR B7        NA    Replacement ALLTHREAD
: 7. Description of Work:            REPLACE BOLTING AND PLUG DUE TO STEAM CUTI ING AND CORRODED BOLTING
: 8. Tests Conducted:              Hydrostatic Other. VT1
                                                            ~      Pneumatic VT2 X      VT3              ~psig          TestTetep.    ~'F Nominal Operating Pressure (ISLT)    X
 
PSL-2, NIS-2 TRACKING NO.                  SL-2        083 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:        A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:          Ph)'h fC      I."I )
APPUCABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                                rt/ S      I      Date ~tZ      I        t tt~5 vmer or      eVs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the'examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL      Com&#xb9;60 InspectoVS Signature                                      National Board, State, Providence and Endorsements Date                                19~>
 
FORM      N-2      CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENA/ACES>>
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Prodtrction                                                  Pg. 1of2
: 1. Manut>>nceed and cecal>>dby          Contest Ca nfronerrft hc.2259t Atwicfd GnprdddAvabo Sarrgt h4aryarttd. CA 92688 hens>>nc address d osrcna>>e Hcsdcrl
: 2. Menufactcsed for          FLORIDA POWER AIVDUGHT. RAT PIERCE. FLORIDA hsn>> cnd eddcsse cr Ccneseci
: 3. Location of hstattaaon        ST. L(IDIEPLANT.(WIT2, FORT PIERCE. FLORIDA hens end address)
: i. Type        82060I612XX'A 182-Pf f                                  70,000 PSI                          H/A                          1992 (dnssne nca)                    hc>>l >>ace. na}            (te>>se crenate                  ftttrr)
: 5. ItsME code, seclon ttL oansion 1:              f980                            NO                                                              N/A (sdtasc)                                                                              (Cade Csee ca,)
tL Fabricated  h accocclance sett consL spec.    (oN. 2 only)              N/A                  sw'e'en          cvA        Dan                NIA ha)
T. ecnsstaca    FDRMCD(JLATIs 1/ENTDRAG VALVE/N26689-I Cgf )1/C4C 6f11f 1- f          PL(Ae WC''850270 rL  Nora fftctcr>>rs (st,)  2.8    Mh. deign tnictcness 0rL) N/A              Ota 0 (ft S h)          1.4'angat      owait (ft S h)      12.6'.
vtr>>napptcabte. Certtccate Holders'Data Re porta are attacned for each fhm of tnta report Habceal                                Part or Apca>>enate>>                    Natlond Swd HcL                                    Serial Ncanber                      Board NcL in Nwnencat Order                                                              h Ncanencat Order 860270  BH 1                                                          (2tL)
(2.)  8602708/H2                                                            (27) p.)                                                                          (2tL)
(4)                                                                          (2(L)
(5)                                                                          pg.)
(a)                                                                          P1.)
(7)                                                                          (32)
(fL)                                                                        (33.)
(0)                                                                          pi.)
(ftL)                                                                          p5.)
(1 1.)                                                                        (3tL)
{12.)                                                                          pl.)
(1 3.)                                                                        PfL)
(1 4.)                                                                        Pg.)
(15.)                                                                          (4tL)
(1 tL)                                                                        (41.)
(1 7.)                                                                        (42.)
(1 5.)                                                                        (43.)
{1 0.)                                                                        (aa)
(30.)                                                                        (45.)
    '3$  .)                                                                        {atL)
(22)                                                                          (47.)
(23.)                                                                        (45)
(34)                                                                          (40.)
(35)                                                                          (50.)
: 10. Oeeign presscse          Q5$              pa.      Temp. 660                            oeg. F      Hydrcc  astpreeaae    N/A    'tacmp.          oeg. F
~ftuPPlenarearannSOCCnht>>rC>>nefaCCS.Ckcaear>>e.CrdnaaCnte      n>>r be  ueed CCCCSted (1) Sae b ~    tftatl.  (g) idrnn>>arC h lane aenda CSC tW OPS ftCPCCt b hcacded cn eedc d>>d    gs ense d>>>> b sera>>csd>>nt tw rsscca>>    ro d>>ccs b cascaded el tee tcp d ten fccnn.
Tria farm  g05a)    cner be cbtahed ecsn he Ceder OsPC ASLE 22 Lees Ortsa Bcscs&#xc3;ZL Fee>>eccl faf OWtr 2XXL Page z3
 
N-2 FORM              N-2 plack Pg. 2 a~2 csrgycoh Hokeer's serial etoa.        XC2S              ehroctger    SrN 1 8 2
~      eoeoehrcknoensedby            K N. CHOW                                                      I E  are    R            sag,          carat I s- sue        hVA      sea. na        N/A
~
tea oerd1  hd fly  ~          made h tlk ~c oe ocnos and tip hta thesee co he asae et ocnerakakn ca he stage code. secckn s. Qklaan s.
AlVEF, 1854k lt I  f 0~tr              COWVROLCCWPCNIENTSJVC hddh e      ~  oorsnbhm    ~      by he etdknct sacro  cd eeoeer oae prseoae vessel epeooore end    tre dirae or    pro@acre et CALIIcURtV14 beet ct my oacedcte oee basal tre        ~
oae ~ crtoeedby      HARVARDS7K4M BOILER hlSPECTJONAND NSUROVCZCCtMPANY Header has bbtcered trees pens or    zgxs~          h eoooneoars ~  tre AslE coos jeodcn
                                  ~
g, crrkicn k Sean pen treed bee bem acrhorkad ear ecamphce cn tw dace etcwn <<xaa sy ekyrhp Ns oerreketa, natrer tw haoecror ncs tsc empioyer makes waarrcnry, etrrsaeeed h tria cats Aaocrk ycatromae, Moat tre hapecror nck nta ~ nploter anat ba tcbl ~ h any eoae cd any khd ananp fram or l'I I g        race trk hapecckn.
                                                                                              ~ or hoaec1 ocakarmhee Q.t +
ear~ perscnat ~ tra aatencnc darorbed or property reenacts or (Nrcl scL hoaadhct ecknwneae axe %de or prot aae na) tR        ~-+~~'age 7  af ~~
 
PSL-2, NIS-2TRACKING NO. S          L-2-8-,        84 FORM NIS-2 OiVIAVERS REPORT FOR REPAIRS OR REPLACEMENTS FPL                            As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/18/95 P. O. Box 529100                              Sheet:  1          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach,  FL 34957                    NPWO &#xb9;: 8211
: 3. Work Performed By:                  Florida Power & Light Co.                      WO &#xb9;: 95012902-01 6501 South Hwy. A1A                            WCD &#xb9;: 0204 Jensen Beach,  FL 34957
: 4. (a) Identification of System        COMPONENT COOLING iVATER                    Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        LINE I-20-CIV-97-2                                    Expiration Date N/A (Mark Number)
(c) Code Class:    3
: 5. (a) Applicable Construction Code and Addenda:            ASME 1971 S 1973 ADD. Code Case:                    N/A (b)  Applicable  Edition of Section XI for Repairs  and  Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other      Year      Replaced      ASME Code Component or      Manufacturer Serial or Heat          Board    identification Built Repaired or        Stamped Material                              No.            No.                              Replacement      (Yor N)
PIPE - 20" SA 106 GR. B          NIA              NIA            N/A          N/A          NIA    REPLACED          NO PIPE - 20"      TIOGA PIPE        HEAT  &#xb9;                    UTC 371811 SA 106 GR. B        SUPPLY          L63840            N/A        RIR 22764      1995  REPACEMENT          NO
: 7. DESCRIPTION OF WORK:                  12" SECTION OF 20" PIPE REPLACED BECAUSE OF PIPE WALL REDUCTION DUE TO CORROSION
: 8. Test Conducted:          Hydrostatic [X ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) []
Other: VT1    []        VT2[X]            VT3 []            105        PSIG      Test Temp.      sYsTEM      F Hold Time 10 MINUTEs
 
PSL-1, NIS-2 TRACKING NO. S          L-2          84 FORIN'IS-2          (Back)                  Sheet    2  of
: 9. Remarks            A HYDRosTATIc PREssURE TEsTwAs succEssFULLY PERFDRMED QN THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
: 10. Inspection Report Numbers:            M95-425 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate    of    Compliance Wecertifythatthestatementsmadeinthereportarecorrectandthis                      [  ]Repair        [ ]Replacement
[X    ] Modification    conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No N/A Signed                                                                        Date  ~<                  19  [5 Owners or OwneVS    Bsigne    itic CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
7 i)                          Commissions Inspectors Signature                              National Board, State, Providence and Endorsements Date
 
PSL-I, NIS-2 TRACKING NO.              SL-2      ~088 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                          As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power & Light Co.                Date:      1/4/96 P.O. Box 529100                          Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucio Nuclear Plant 6501 South Hwy. AIA                      P.O.&#xb9;:    NA JensenBeach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By.              Florida Popover & Light Co.              PWO&#xb9;: 4808 6501 South Hwy. A1A WO &#xb9;:      95023617 Jensen Beach, FL 34957 CWO &#xb9;: NA            Process Sheet:  N/A
: 4. (a) IdenSication      of System      Chemical 8 Volume Control Type Code Symbol Stamp    N/A CHG PP 2A                                        Authorization No.        N/A (b) Component Identification:                                                                      Expiration Date          N/A (Mark Number)
(c)  Code  Class:        2
    )  Applicable Construction Code and Addenda:        ASME SEC. III;  '3  ED., 'S. '4  ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National        Other        Year      Replaced      ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                      No.        No.      Identification                    of      Stamped Material                                                                                    Replacement (Yor N)
VALVECOVER NUT          NOVA MACHINE          HT&#xb9; 2FCS76        NA        SA 194; GR 6      NA      Replacement
: 7. Description of Work:      REPLACE VALVE COVER NUT WHICH WAS FOUND TO BE CRACKED.
(POSSIBLY OVER TORQUED)
: 8. Tests Conducted:      Hydrostatic Other: VT1
                                                    ~    Pneumatic VT2 X        VT3 Nominal Operating Pressure(ISLTI
                                                                                      ~psig          Test Temp.    ~'F  X
 
0 0
 
PSL-2, NIS-2 TRACKING NO.                  SL-2-8<<085 FORM NIS-2 (Back)                                          Sheet 2 of 2
: 9. Remarks:          A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:                  ~~    Ig -Z.4 l+
APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                              Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
,  Type Code Symbol Stamp:
of Authorization No.: N/A N/A'ertificate go Signed                                                EUr v.                  DateM                  19  tt ner        ei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this OwneVs Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVs Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, rio addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
                      .g In pectoi's Signature Commissions              NB7719      FL Com      &#xb9;60 National Board, State, Providence and Endorsements Oate
 
PSL-2, NIS-2 TRACKING NO. S L 8 -              86 FORM NIS-2 OiVIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power  & Light Co.                      Date: 12/27/95 P. O. Box 529100                              Sheet:  1          of  2 Miami, FL 33152              i                  Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO &#xb9;: 7709
: 3. Work Performed By:                  Florida Power  & Light Co.                    WO &#xb9;: 95010526-01 6501 South Hwy. A1A                            WCD &#xb9;: N/A Jensen Beach,  FL 34957
: 4. (a) Identification of System        STEAM GENERATOR                            Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        MANiVAY,SECONDARY SIDE                                Expiration Date N/A (Mark Number)
(c) Code Class:    3
: 5.  (a) Applicable Construction Code and Addenda:          ASME 1971 S 1973 ADD. Code Case:                    N/A (b) Applicable Edition of Section XI for Repairs  and  Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other        Year    Replaced      ASME Code Component or        Manufacturer Serial or Heat          Board      Identification Built Repaired or        Stamped Material                              No.            No.                              Replacement      (Y or N)
STUD - SA540      COMBUSTION          HEAT  &#xb9; 1-1/2" X 9"      ENGINEERING          82158          N/A        UTC 388124    1983  Replacement        NO
: 7. Description Of Work:                  BOLTING MATERIALREPlACED BECAUSE OF WORN THREADS DUE TO NORMALWEAR AND TEAR.
: 8. Test Conducted:          Hydrostatic [ ]                Pneumatic  []                  Nominal Operating Pressure (ISLT) [X ]
Other: VT1    []        VT2[X]            VT 3 []          sYsTEM      PSIG      Test Temp.      sYBTEM      F Hold Time 4 HQURs
 
PSL-1, NIS-2TRACKING NO. S            L-2          86 FORM NIS-2          (Back)                  Sheet  2  of
: 9. Remarks            AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
: 10. Inspection Report Numbers:            M95497 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                  [X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:              N/A Certificate of Authorization No Nl Signed                                                                        Date    /Z. Z T,          19 ~b Owners o Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board      of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Ownei's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.                SL-2                                            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP                      As Required by the Provisions of the ASME Code Section XI
: l. Owner:                      Florida Power & Light Co.                Date:      12/13/95 P.O. Box 529100                          Sheet:      I  of 2 Miami, FL 33152 Unit:
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:            Florida Power & Light Co.                PWO&#xb9;: 3638 6501 South Hwy. A1A WO &#xb9;:      95002817 Jensen Beach, FL 34957 CWO      &#xb9;: NA        Process Sheet:        N/A
: 4. (a) Identification of System:      Main Steam Type Code Symbol Stamp          N/A Authorization No.              N/A (b) Component Identification:    V08163 Expiration Date                N/A (Mark Number)
(c) Code Class:        3 ASME Sect III 1974 Ed/S 76 Add            Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components; Type of            Name of          Manufacturer    National      Other          Year      Replaced            ASME Component        Manufacturer        Serial or Heat  Board                          Built    Repaired            Code or                                    No.        No.      Identification                                  Stamped OI'eplacement Material                                                                                                          (Yor N) a ve isc          aciic ave                                                                    ep ace 600 Ib /4'                                                          Gr WCB e isc          aci ic a ve          eat  o                            26              Rep acemen 600 Ib /4                                26M3                      Gr WCB
: 7. Description of Work:      Replaced disc which was damaged during disassembly
: 8. Tests Conducted:        Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2
                                                          ~      VT3                      psig    Test Temp.                  'F
 
PSL-2, NIS-2 TRACKING NO.              SL-2                                                    FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        N~ q      cP APPLICABLE MANUFACTURES DATAREPORTS  To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  +Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Stgaeg        Jl/(!Zl,      I  5              RP V        IS (          DateZEC        (3, 19~
Owne or      nei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors and the State or    Providence    of Florida  and employed  by Factory  Mutual  Engrg Assoc.
have inspected the components        described    in this Owner's Report during  operating  cycle  &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 19S9 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
: 8. Inspector's Signature Commissions National Board, State, Providence and Endorsements Date
 
PSL-1, NIS-2 TRACKING NO.              SL-2                                            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power & Light Co.                Date:      11/29/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. AlA                      P.O  &#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:            Florida Power  & Light Co.              PWO&#xb9;: 8958 6501 South Hwy. A1A WO &#xb9;:      94009167 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:      N/A
: 4. (a) Identification  of System:      Safety Injection Type Code Symbol Stamp          N/A Authorization No.              N/A (b) Component                    HCV-3512 Identification:
Expiration Date                N/A (Mark Number)
(c) Code Class:    2 ASME Sect III 74 Ed. / Sum 76 Add        Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other          Year      Replaced            ASME Component        Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                      No.        No. Identification                                  Stamped OI'eplacement Material (Y or N) e ge              ames urry                                                                  ep ace (Disc)              Corp.                                        Gr CFSM e ge              ames urry            ena  o                        3                    ep acement (Disc)              Corp.              NJV-2                    Gr CFSM
: 7. Description of Work:      Replaced disc due to leakage.
no root cause identified.
: 8. Tests Conducted:        Hydrostatic              Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2~          VT3                    psig    Test Temp.                  'F
 
PSL-2, NIS-2 TRACKING NO.                  SL-2-S-FORM NIS-2 (Back)                                          Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:          )5 f6 Q Q -3, 5 QQ APPLICABLE MANDFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                              +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed      (    k(            sR Pieei'Snp"e            - (S                Date  ~d 2-'f, 19          Lg ne    r Ovine VS Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors  and the  State  or Providence    of Florida  and employed  by Factory  Mutual  Engrg Assoc.
have  inspected  the  components      described  in this Owner's Report during  operating  cycle  f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                        National Board, State, Providence and Endorsements Date
 
PSL-2. NIS-2 TRACKING NO.                SL-2                                                FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power    & Light Co.              Date:      12/13/95 P.O. Box 529100                            Sheet:      I  of  2 Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:    NA Jensen Beach, FL 34957                      PCM &#xb9;: NA
: 3. Work Performed By:              Florida Power & Light Co.                  PWO&#xb9;: 3624 6501 South Hwy. A I A WO &#xb9;:      94025119 Jensen Beach, FL 34957 CWO      &#xb9;: NA        Process Sheet:  N/A
: 4. (a) Identification  of System:        Safety Injection Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component ldentiTication:        V3468 Expiration Date          N/A (Mark Number)
(c) Code Class:          2
    ) APPlicable Construction Code and Addenda:              ASME Sect lii 1989 Ed / No Add            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components      Repaired or Replaced and Replacement Compo'nents:
Type of            Name of            Manufacturer    National      Other          Year      Replaced      ASME Component          Manufacturer,          Serial or Heat  Board                          Built    Repaired      Code or                                        No.        No.      Identification                    of        Stamped Material                                                                                        Replacement (Yor N) net    u s                  aw                                                3                    ep ace 5/8 -11unc2A                                                              Gr 87 n et tu s                ova                eat  o                        193                  ep acement 5/8 -11unc 2A                                9965663                      Gr 87 n et  uts                  aw                                        S  194        NA        Rep ace 5/8 -11unc 28                                                              Gr2H n et  uts          ie    ut    8~et        eat o                          194                  Rep acement 5/8 -11unc 28                                  97365                      Gr 2H
: 7. Description of Work:        Replaced bolting due to corrosion
: 8. Tests Conducted:          Hydrostatic                Pneumatic                Nominal Operating Pressure (ISLT)
VT2          VT3                              Test Temp.            'F Other: VT1                                                    psig
 
PSL-2, NIS-2 TRACKING NO.                SL-2                                                  FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
NNqQ          n  I Qg
: 10. Inspection Report Numbers:
APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                        +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A SIgned    I    A          cd  ~
Owner r Owners Designee, Title pcc  ISc                Once&~a'.c    I, I      gag CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board      of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions inspector's Signature                                    National Board, State, Providence and Endorsements Date
 
PSL-I, NIS-2 TRACKING NO.            SL-2            ~090
                              ~            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                        Florida Power  & Light Co.              Date:      11/25/95 P.O. Box 529100                        Slicct;    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                        St. Lucio Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                  PCM &#xb9;: 179-295M
: 3. Work performed By.            Florida Power & Light Co.              PWO&#xb9;: 5488 6501 South Hwy. AIA WO &#xb9;:      95032597 Jensen Beach, FL 34957 CWO    &#xb9;:            Process Sheet:        N/A
: 4. (a) Identification  of System:    Safety Injection Type Code Symbol Stamp          N/A HCV-3512                                        Authorization No.              N/A (b) Component Identification:                                                                    Expiration Date                N/A (Mark Number)
(c) Code Class:      2
    ) Applicable Construction Code and Addenda:                          NA                        Code Case: None (b) Applicable Edition of Section    XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Rcplaccment Components:
Type of              Name of        Manufacturer    National        Other        Year      Replaced            ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                      No.          No. Identification                                  Stamped oi'eplacement Material (Yor N)
FLAT BAR          FRY STEEL CO            HEAT&#xb9;                  SAR79 TP 316        NA        Replaced 1/4 X1/2                                A1 2060 FILLET WELD                FPL          WELD TRAV&#xb9;        NA            NA          1995    NEW WELD 3583                                  95-3583
: 7. Description of Work:      SECURE PIN TO THE VAVLE DISC BY WELDING TO PREVENT DISC FROM ROTATING AROUND STEM.
: 8. Tests Conducted:        Hydrostatic Other. VT1
                                                ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure (ISLTI
                                                                                    ~psig          Test Temp.         ~'F   X


PSL2,NIS2TRACKINGNO.SL-2-9-~019FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-584APPLIGABLEMANUPAGTURE'sDATAREPORTsToBEATTAGHEOCertificateofComplianceWacertifythatthestatementsmadeinthereportarecorrectandthisRepairQRepiacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned8Irg~or-ZKT'rowner'sDesignee,TitleDate~VIito.f9~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sgnatureCommissions71m&#xb9;NationalBoard,State,ProvidenceandfndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2C-~020FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miam,FL33152St.LucioNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2CHPP2C3.WorkPerformedBy:FloridaPower4LightCo.6501SouthHwy.A1AJcnsenBcach,FL349574.(a)IdentificationofSystem:Chemical&VolumeControlDate:2/6/96Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:386-288DPWO&#xb9;:0775WO&#xb9;:94010958CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEC.III71ED-72ADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialSUCTIONSPOOLPIECECAPSCREWNameofManufacturerUNIONPUMPManufacturerSerialorHeatNo.NationalBoardNo.NAOtherIdentificationSA564GR630YearBuiltNAReplacedRepairedorReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:REPLACECAPSCREWSWHICHWEREREMOVEDDURINGMAINTENANCEOFPUMP.6.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2C-~020FORMNIS-2(Back)Sheet2of29.Remai'ks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:MM95-1919APPUCABLEMANUFACTURESDATAREPORTSToBEATTACNEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignederoei'sDesignee,TitleCa~eQk6<0~GCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.CBysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsg1g4NB7719FLCom&#xb9;6889')NationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-~021FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:V2326(MarkNumber)3.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:Chemical&VolumeControlDate:07/12/95SheeL1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:7756WO&#xb9;:93020470CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:25.(a)ApplicableConstructionCodeandAddenda:ASMESECT.III74EDrnON/NoADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilized.forRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialDiscInsert11/2"X2"NameofManufacturerCrosbyValveManufacturerSerialorHeatNo.S/NN91102-51-0080NationalBoardNo.NAOtherIdentificationHaynesStelllteAlloy68YearBuiltNAReplacedRepaired'I'eplacementReplacedASMECodeStamped(YorN)DiscInsert11/2"X2"Nozzle11/2"X2"Nozzle11/2"X2"CrosbyValveCrosbyValveCrosbyValveS/NN91102-99-0065S/NN91469-34-0013S/NN91469-36-0015NANAHaynesStelllteAlloy68ASMESA479Type316ASMESA479Type316NAReplaced1988Replacement1987Replacement7.DescriptionofWork:RebuildvalveSNN59200-00-0005.ReplaceddiscandNozzleValvetobeusedasspare.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)Other:VTIVT2VT3~psigTestTemp.~'2 PSL-2,NIS-2TRACKINGNO.SL-2-0-~021FORMNIS-2(Back)Sheet2of29.Remarks:None10.InspectionReportNumbers:NAAPPLICABLEMANUFACTUAESDATAAEPOItTSTOBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisRepairXReplacementconformstotherulesoftheASMECode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedmfa'-ZVPV,LGi,0nerowner'sDesignee,TitleDatehI,1995CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.tnspecor'sSigatureCommissionsF&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate19~5 PSL-1,NIS-2TRACKINGNO.SL-2-8-022gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3SB212514.(a)IdentificationofSystem:IntakeCoolingWaterDate:11/25/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2160WO&#xb9;:94030738CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectionIII,1971edition,noad.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialSTEELPLATE3/8X48X96NameofManufacturerBETHLEHEMSTEEManufacturerSerialorHeatNo.RIR&#xb9;2FC318NationalBoardNo.NAOtherIdentificationASMESA515G70YearBuiltReplacedRepairedorReplacementReplacementASMECodeStamped(YorN)FW2000BUTTWELDFW2000BUTTWELDFPLFPLWELDTRAVL&#xb9;95-2712WELDTRAV&#xb9;95-2713NALINE&#xb9;CW-20NANALINE&#xb9;CW-21NANEWWELDNEWWELD7.DescriptionofWork:REMOVEVALVESANDCAPOFFPIPINGWITHPLATE.MATERIAL.NEWWELDADDED.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(tgLT)Other.VT1VT2XVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~022FORMNIS-2(Back)Sheet2of29.Remarks:go<<iVGL<+<~I10.InspectionReportNumbers:2-ZPT-QlAPPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedIIOwner'wner'sDesignee,TitleDateIoae2919'ERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwneVsReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate/f,19~
PSL-2, NIS-2 TRACKING NO.                   SL-2       ~000 FORM NIS-2 (Back)                                         Sheet 2 of 2
ST.LUCIEUNIT2TECHNICALDEPARTMENTPROCEDURENO.2-IPT-32,REVISIHYDROSTATICPRESSURETESTICWLOOP'B'agy7'of9TESTDATASHEETTESTDESCRIP77ONQSYSTEMLEAKAGETESTQSYSTEMFUNCTIONALTESTQSYSTEMLNSERV(CETEST~SYSTEMHYDROSTATICTESTQSYSTEMPNEUMATICTESTQINSTRUMENTEDINSPECTION(IIT)QSCHEDULEDQUNSCHEDULED'EPAIRQREPLACEMENTS'REVIEWbyISIREQUIREDTESTCONDmONSSYSTEMCODECLASS:Q1(A)SYSTEMDESIGNPRESSURE:SYSTEMOP.PRESSURE:SYSTEMDESIGNTEMP:SYSTEMOP.TEMP.:REFERENCEDRAWING(S)'2(B)~3(C)90PSIG60PSIG125oF90'F2998-&482CurrentRevisionTESTCONDmONHOLDTIMESYSESCI'B'NTAKECOOLINGWATERPUMPDISCTESTMEDIUM:SEAWATERWATERCHEMISTRY:NOMINALICWPLANTSOURCE:ScreenWashPumpsTESTTEMP:AMBIENT'.FEXAM.TEMP:AMBIENT'FINSULATEDQ0-MIN(SYSLEAKAGE)Q10-M(N(FUNCTIONAL)Q10-MIN(PNEUMATIC)Q4-HOUR{HYDRO)Q4-HOUR(INSERVICE)N0NINSUIATED'I0MIN(SYSLEAKAGE),Q10-MIN(FUNCTIONAL)Q10-MIN(PNEUMATIC)~10-MIN{HYDRO)'10MIN(INSERVICE)ANIIWETNESSQREQUIRED.WAIVED~~Sea.coalANIIDATKTESTRESULTSSUMMARYZ.30Z.le~TESTTIMETABLEACHIEVEDTESTCONDITIONSACHIEVEDREQUIREDHOLDTiMECOMPLETEDVT-2EXAMINATIONMEASURING&TESTEQUIP.MASTERGAUGE~BACKUPGAUGE77MEI190IDENT.DATE1-2.g+I(-id<II-~3qS/j->>.EXAMJTESTPERSONNELMETHODV72-LEVELQSTARQNPWO0OTHERaGATE.~Z"IDISCREPANCIESTESTSUPV.AN!I:FINALTESTREVIEWATE:-?DATE:
: 9. Remarks:     A   ~w+c4N                  1~+~4~         ~ l~Q< ~
/Page7of10ST.LUCIEUNIT2TECHNICALDEPARTMENTPROCEDURENO.2-IPT-31,REVISION3"'-'YDROSTATICPRESSURETESTICMILOOPAANDCTESTDATASHEETGeneralTestDataQSystemLeakageTestQSystemFunctionalTestQSystemInserviceTest8SystemHydrostaticTestQSystemPneumaticTestQInstrumentedlnsectionIQScheduledQunscheduled'gRepair'Replacements'ISICoordinatorReviewTConditionsSystemDescription:IntakeCoolinWaterPumDischABCSystemCodeClassQ1(A)Q2(B)SystemDesignPressure-90SystemOp.Pressure60SystemDesignTemp:125SystemOp.Temp:90$5ReferenceDrawing(s)29986-082CurrentRevisionTestonditionHoldTimePSIGPSIG'FdFTestParametersTestmedium:SeaWaterWaterChemistry:NominalICWPlantSource:ScreenWashPumsTestTemperature:Ambient'FExam.Tem.:Ambient'FInslaQ0-min{SysLeakage)Q10-min{Functional)Q10-min{Pneumatic)Q2-hour(IIT)Q4-hour(Hydro)Q4-hourlnserviceNninIQ0-min(sysLeakage)Q10.min(Functional)Q10-min{Pneumatic)010-min(Hydro)Q10-min(lnservice)Q10-minIANIIWitnesORgereredMWei~edANIIDatetr-iTtResulsSummaTestTimetablAchievedTesn'inAhivedReuioldTimeIVT-xiinMe'nTeuiZmme22,<<I{IdntDteIDaeTestImplementationsAza~sI~SBZ{Z.<lAtrgz.Sckuau-ZSIO-Sl-9-Z0-SllR<sT~<AeemcbPfFSRYbPe~Lu~~goot4P<O2-/f,oExamJTestPerennelMethodU<~LvelPostTestDireanieEf~C6WOaSOI%~0QOtherTestEng~..ISICoor.:ANII'.~nalTeteviewDate:/-/l85Date:IIDate:~6~
CA'Hgeg Itnz~cS/,
PSL-2,NIS-2TRACKINGNO.SL-2-3-~023gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.'wner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHvvy.A1AJensenBeach,FL34957FloridaPovver&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2CHGPP2B4.(a)IdenQicationofSystemChemical&VolumeControlDate:1/22/96Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4812WO&#xb9;:95023706CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDate.N/A(a)ApplicableConstructionCodeandAddenda:ASMESEC.III;1971ED.;W72ADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedoi'eplacementASMECodeStamped(YorN)FLUIDBLACKASSEMBLYFLUIDBLACKASSEMBLYUNIONPUMPN52918-NS/N2UNIONPUMPN52918-NS/N2NASA182TYPE304NASA182TYPE30419761988ReplacedReplacement7.DescriptionofWork:REPLACEFLUIDBLOCKDUETOCRACKING.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther.VT1VT2XVT3~psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~023FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:WgQAPPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AsISne8t4AsR(88>T5IPU-Isieror0r'sDesignee,TitleDate~2.,19~~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-I,NIS-2TRACKINGNO.SL-2-8-~824FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucicNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V34143.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:12/13/95Sheet:Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4058WO&#xb9;:95012105CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialSealWeld(FW2003)NameofManufacturerNAManufacturerSerialorHeatNo.HtNoGT61000434NationalBoardNo.OtherIdentificationER316(P8toP8)YearBuiltReplacedRepairedorReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:Removeandreplacesealweldtofacilitatevalvework.8.TestsConducted:Hydrostatic~PneumaticNominaiOperatingPressure(ISLTIXOther:VTIVT2XVT3~PsigTestTemP.'F PSL-2,NIS-2TRACKINGNO.SL-24I-~024FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-2352APPUCABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedAuuk,ot/.-lS(vmervmeVsDesignee,TitleCaIe~l.,IS~5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwneVsReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Ispector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate,19~%
1
PSL-1,NIS-2TRACKINGNO.SL-2-8-025FORMNIS-2OWNERtSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPowerkLightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35513.WorkPerformedBy:FloridaPowerkLightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/22/95Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2821WO&#xb9;:95007333CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialSEALWELDFW-2002NameofManufacturerFPLManufacturerSerialorHeatNo.WELDTRAVELO&#xb9;95-2473NationalBoardNo.NAOtherIdentificationSA-182316SSYearBuiltReplacedRepairedorReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:Removeandreplacesealweldtofacilitatevalvework.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~pstgTestTemp.~'P
: 10. Inspection Report Numbers:         IAN95 Q.9        ~
APPUCABLE MANUFACTURES DATA, REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                    X Repair        Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 0  er or Pb >qg ei's Designee, Title IS<                Date  Po U  ~,       19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719    FL  Com&#xb9;60 inspector's Signature                                        National Board, State, Providence and Endorsements Date        j


PSL-2,NIS-2TRACKINGNO.SL-2-8-~025FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:fAKt5-Q~~IAPPUCABLEMANUFACTURESDATAREPDRTBToBEATrACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned'cCCOwerorer'sDesignee,TitlePu-lhlDate~0t/~19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwneVsReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate
PSL-1, NIS-2 TRACKING NO.               SL-2                                                 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI
: 1. Owner:                            Florida Power & Light Co.                Date:      12/7/95 P.O. Box 529100                          Sheet:      1  of Miami, FL 33152 Unit:      2
: 2. Plant:                               St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By                    Florida Power & Light Co.                 PWO&#xb9;: 3638 6501 South Hwy. A1A WO &#xb9;:      94025126 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet: N/A
: 4. (a) Identification        of System:     Main Steam Type Code Symbol Stamp    N/A Authorization No.        N/A (b) Component                          V08130 Identification:
Expiration Date          N/A (Mark Number)
(c) Code Class:          3
    ) Applicable Construction Code and Addenda:              ASME Sect III 1974 Edition/S 75 Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989,Edition.
: 6. Identification        of Components    Repaired or Replaced and Replacement Components:
Type of                  Name of        Manufacturer    National      Other            Year      Replaced      ASME Component              Manufacturer        Serial or Heat    Board                          Built    Repaired      Code No.          No. Identification                    or      Stamped oi'aterial Replacement (Y or N)
ISC                      acI ic                                                                    ep ace (4'heck        )            Valves                                        Gr WBC ISC                      on ro            eat o                          26          199      ep acement (4 Check)                Components            A0342                      Gr WBC
: 7. Description of Work:            Replaced disc assembly due to damage.
: 8. Tests Conducted:              Hydrostatic            Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig    Test Temp.             'F


PSL-1,NtS-2TRACKINGNO.SL-2C-~026FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower4LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPowerkLightCo.6501SouthHwy.AlAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2HCV-36164.(a)IdentificationofSystem:SafetyInJectionDate:11/14/95Slleet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2418WO&#xb9;.95001976sCWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedofReplacementASMECodeStamped(YorN)SealWeldNAHtNoDT6289NAP8ToP8ER316NAReplacement7.DescriptionofWork:Removesealweldforvalveinspectionandreweldfollowingexamination.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~psigTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-6-~026FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:PA)RQG-Q,K5+APPUCABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedAROwnerrei'sDesignee,TitleDate~AVI19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwneVsReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwneVSReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.8vinspectorsS!gnatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate/19<6 0
PSL-2, NIS-2 TRACKING NO.                 SL-2Z-FORM NIS-2 (Back)                                         Sheet 2 of 2
PSL-1,NIS-2TRACKINGNO.SL-2-8-027FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:'.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AlAJcnscnBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35234.(a)IdenQicationofSystem:SafetyInjectionDate:11/14/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2863WO&#xb9;:95009205CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialSealWeldNameofManufacturerNAManufacturerSerialorHeatNo.HtNoDT6289ER316FillerNationalBoardNo.NAOtherIdentificationP8ToP8(SA-182FQ16)YearBuiltNAReplacedRepairedorReplacementReplacedSealWeldASMECodeStamped(YorN)7.DescriptionofWork:Removesealweldforvalveinspectionandreweldfollowingexamination.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther.VT1VT2XVT3~psigTestTemp.'F
: 9. Remarks:         A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:       +W    IQ  (3, W APPLiCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorizati n No.: N/A Signed Ow      or Own  i'esignee, EL Title PbattP        I/ l5    Date~, 19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Providence and Endorscments Date


PSL-2,NiS-2TRACKtNGNO.SL-2-8-~927FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:'gINQQ-Q,RESAPPUCABLEMANUFACTURESDATAREPORTSTOBEATTADHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedIAaKPLtttttrR%/-Owner'sDesignee,TitleDate~CI/t519~7CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorscmentsDate PSL-I,NIS-2TRACKINGNO.SL-2-2-EPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2MV-08-1B3,WorkPerformedByFloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:11/29/95Sheet:1of2Unit:P.O.lf:NAPCM/I:NAPWO//:8726WOf/:94007112CWOf/:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1974Ed/S74Add.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOfMaterialiscternAssemblyDiscternAssemblyNameofManufactureroeoeManufacturerSerialorHeatNo.eatoH2261enaoH6572NationalBoardNo.OtherIdentificationTP3164TP316YearBuilt963ReplacedRepairedOI'eplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedstem/discassembly,oui"+'~~~'+~Qc'ote-requiressealweldreplacement.TrackedonPWO95013022NISNo.SL-2-8-0398.TestsConducted:HydrostaticOther:VT1PneumaticNominalOperatingPressure(ISLT)VT2VT3psigTestTemp.'F
PSL-2. NtS-2TRACtONG NO.             SL-2           ~892 g            FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                       Florida Power & Light Co.               Date:       1/2/96 P.O. Box 529100                        Sheet:
Miami, FL 33152 Unit:      2
: 2. Plant:                         St. Lucie Nuclear Plant 6501 South Hwy. A1A                    P.O.&#xb9;:     na Jensen Beach, FL 34957                  PCM&#xb9;:       na
: 3. Work Performed By:           'lorida Power & Light Co.                PWO&#xb9;: 2960 6501 South Hwy. A1A WO &#xb9;:       950103040 Jensen Beach, FL 34957 CWO &#xb9;:                 Process Sheet:       N/A f
: 4. (a) IdenQication o System:         Auxiliary Steam Type Code Symbol Stamp          N/A AFW PP 2B                                        Authorization No.             N/A (b) Component Identification:                                                                    Expiration Date                N/A (Mark Number)
(c) Code Class:       3
    ) Applicable Construction Code and Addenda:        ASME SEC. III; 1974 ED., NO ADDENDA Code Case: None (b) Applicable Edition of Section    XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of          Manufacturer    National        Other          Year    Replaced            ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                    No.         No. Identification                                  Stamped OI'eplacement Material (Yor N)
CAPSCREWS        INGERSOLL RAND              &#xb9; HEAT 94521        NA      SA 193; GR B7      NA      Replacement
: 7. Description of Work:     REPLACE BOLTING DUE TO THREAD DAMAGE,.
: 8. Tests Conducted:       Hydrostatic Other: VT1
                                                  ~      Pneumatic VT2 X        VT3 Nominal Operating Pressure (18LT)
                                                                                    ~pstg          TestTemp.         ~'P    X


PSL-2,NIS-2TRACKINGNO.~SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:(5%$5-g,~I@APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned<Q.P~,wnerner'sDesignee,TitleDate~L'~,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.1BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate,19~~.
PSL-2, NIS-2 TRACKING NO.                 SL-2       ~092 FORM NIS-2 (Back)                                       Sheet 2 of 2
PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy'loridaPowerEcLightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:11/29/95Sheet:1of3Unit:P.O.//:NAPCMf/:009-293MPWOf/:WOf/:94005831CWOf/:ProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V181270(serviceair)4.(a)IdentificationofSystem:ServiceAirTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESectIII1986EditionNoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialae2Checkae2CheckIpe2Sch40pe2Sch40200soet(OldweldNoFW14)2soet(OldweldNoFW13)NameofManufacturer0enoramgawicagoueroneraveer95-2739eraveer95-2740ManufacturerSerialorHeatNo.2J12206NationalBoardNo.OtherIdentification1006GrB106GrBierER7082ierER7082YearBuiltReplacedRepairedorReplacementepaceepacementepaceepacemenepacementepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedvalveduetoleakage.replacebywelding.Includesreplacementofsectionofpiping.(ThisvalveisaCIVIpenis)8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of39.Remarks:AsatisfactorypneumatictestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignederorner'sDesignee,TitleiKopvDate~Cl,IS~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyclef/8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-I,NIS-2TRACKINGNO.SL-24-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsofthcASMECodeSectionXIPLSUPPLEMENTALSHEET1.Owner:2.Plant:FloridaPower0LightCo.P.O.Box529100Miami,FL33152St.LuciePlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.AIASheet:Unit&#xb9;:3of3P.O.&#xb9;:'PCM&#xb9;:NA009-293MDate:4f22I946.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentsoe(OldweldNoFW12)NameofManufacturereraveer95-2741ManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationeraveer95-2740YearBuiltReplacedRepairedOI'eplacementepacemenASMECodeStamped(YorN)
: 9. Remarks:         A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
FORMNPV-1CERTIFICATEHOLDERS'ATAREPORTFORNUCLEARPUMPSORVALVESeAIRequIgodbytnef)rovtahf)IoftheASMECode,Se0tIonIII,DlvIalon1'Pg.ofManufacturedsndcertifiedbyAnchor/DarlingVa1veCo.,701FirstSt.,Wi11iamsport,PA1770(nanoendaddressofNCart(()cataHo(dar)MfctusdfF1oridaPower8LihtComan,P.0.8ox029950,Niami,FL33102-9950(nsmsandaddressofPurchaserorOwner)3,LocationofInstallation4.ModelNo.,SeriesNo.,orType(nemoandaddress)Gbore~W9323936R.AcjjN=B.Pumporvalve7Mater(a).BodySA216-WCBted)don)NominalInlets(aBonnet(addendadate)2II(dass)(In.)06-600-10Ij(CodaCaseno.)2nlalcen.Ho(der'aSer(alNo.E-T488-5-1E-T88-5-2lblNat'IBoardNo.N/NAIclBodySerialNo.ldlBonnetSerialNo.HT.&#xb9;C0607IelOlskSerialNo.TCA761ATA61A'Suoo(ements(lnfonnsooninformof((ets,sketches.ordrawingsmaybeusedprovidedl1)e(aels8)5'11,(2linfonnaoonin(terna1through4onthisOatsiteoortisincludedoneachsheet,(3)eachsheetisnumberedsndthenumberofsheetsisrecordedatthetoooftheform.('I2/88)thisform(8)0037)msybeobtainedfromtheOrderOeot..ASM8.22LawOr(vs.Box2300.Febfleld,NJ070072300.isk'-+g-2.-Q-0Q.QiR~Wpagef~at~
: 10. Inspection Report Numbers:       Ivt re Q g
ST.LUCIIT2OPERATItlaPROCEDURENO.2-1300051,REVISION$3LOCALLEAKRATETESTtsDATASHEET4TestProcedureNote:Makealistofailcapsandflangesthatareremoved,lntheRemarksSectionbelow.5,Qtosasglgl2.$'IH)geto1.CloseV-18-1253,+~%-,SH-18-797.2.OpenV-18-784andV-18-1271(VentPath).he>SH-IS-f254.3.Pressurizeagainst2-IY-18-1270throughSH-18-1254.4.Measureandrecordleakage.loseV-18-784andt-HCV-18-2.S10penSH-18-1252(VentPath).X$Pressurizeagainstl-HCV-18-2throughV-18-1271.g')Measureandrecordleakage.Sl>CloseSH-18-1252.16:llOpenV-18-784(Seepage2of2).PenetrationNo:TypeTest:TestPressure:TestMedia:TestLocat)on:TestFittingsRequired;ValveNo.GaugeSerialNo.Stat)onAlr{Pg.1of2)Bypass41.8(+1.1,%)psigAirorN,23'ontainment1"femaleadapter2-lv-18-1270I-HCV-18-2JSa..Twogo.~e~~sWtt,to,~ca>~IV't.oa{fsoues-Qsyr%ATfa~pQ<<~4~04~RL~rTvrC'~~v'~r=c>(o~m~4.f5',eg~Sa~++Ceel.eve~+tl~p~s(+O,-ga~>~wWQeclestK~VraS'rCArRW~~~Po~lg.Q.,fs)strutsyANllO'C,LAcu+Np&r@sst,gg~fpSt,l'ts/s&ehgallt)sm<Peaes~/&+Sat,rt~/Q5pygmy(yg~))t'o+e6'+4ousda'<a.Ai4~HoQ'~~~+P~S~Se~4aLleWJf$(fS~)P5g$'OrlOartoisgsa4qsap6+arm'tr/T2OCttff1jff~7g~Q.o4-8~5cwpmgckpasxeekpPlychLemai<4;s~)"reaa&DC~~~eP~~~~>t>e.+n+bau.<da.~+LP~+es+cm+v&9,)S.SP-o(.eeJ+~s~~,~RotameterSerialNo.RotameterRange5QC~DateTimeStartTimeEndPressureStartPressureEndLeakage(SCCM)LeakageLimit(SCCM)VerifiedBy-z/-p8,000T6--/5\5/sZSS/O8,000RoasonForTest:G18MonthSorveittanoePreMaintgPstMaintCIOtherRemarks;0Vi0--2.Iril-Rseau..~m~/-~'IPSle>>F-tv..~Q6~CCruLC<4IreePtrCSbsasCAC&Sntattraa...oAsos.APrJsoSto2.t(t,iVT~/Zr//z/<$
APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X Replacement conforms to the rules of the ASME Code, Section XI.
PSL-2,NIS-2TRACKINGNO.SL-2-8-31FORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsofthcASMECodeSectionXI1.Owner2.PlantFloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957Date:12/19/95Sheet:1Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8507of53.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957WO&#xb9;:95026315-01WCD&#xb9;:02444.(a)IdentificationofSystem2Aa2BDIEsELoILTRANsFERLINEsTypeCodeSymbolStampN/AAuthorizationNo.N/A(b)ComponentIdentification1-2"-DO-62&1-2"-DO-63ExpirationDateN/A(MarkNumber)(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1974S1974ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)PIPE-2"SA106GR.BPIPE-2"SA106GR.BPIPE-3"SA106GR.BNIATIOGAPIPESUPPLYTIOGAPIPESUPPLYNIAHT.&#xb9;637224&N68491HEAT&#xb9;N68491N/AN/ANIAUTC379890RIR29032UTC381359RIR2J-1100N/A19951994REPLACEDREPLACEMENTMODIFICATIONNONONO7.DESCRIPTIONOFWORK:LEAKAGEOF13GAL.PERDAYIDENTIFIEDINORIGINALLINE.REPLACEMENTWITHMODIFICATIONTOPROVIDEIMPROVEDCORROSIONPROTECTION.8.TestConducted:Hydrostatic[X]Pneumatic[X]NominalOperatingPressure(ISLT)[X]Other:VT1[]VT2[X]VT3f]HYDRo-150PSIGTestTemp.1HR.@sYs.FIsLT-110PSIGTestTemp.10MIN.esYs.F PSL-1,NIS-2TRACKINGNO.SL-2-8-31FORMNIS-2(Back)Sheet2of9.RemarksHYDRosTATIGTEsTsANDIsLTwEREsUGGEssFULLYPERFoRMEDANDWITNESSEDBYCERTIFIEDQ.C.INSPECTORS.10.InspectionReportNumbers:ISLT-M95438HYDRO'S-M95-157,M95-196,M95-197,M95-377,M95-388,8M95-389APPLICABLEMANUFACTURER'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]Replacement/fX]ModificationconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwner'sDBgnee,TIDateQeC.kl,1915CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate19~<'
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                  SU V    IG                    Date          8       19  Q4 Ovm      r Ovmer's Oestgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
PSL-2,NIS-2TRACKINGNO.SL-2-8-31FORMNIS-2OWNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/19/95Sheet:3Unit:2of52.PlantSt.LucieNuclearPlant6501SouthHwy.A1AP.O.&#xb9;:N/APCM&#xb9;:096-295JensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.,6501SAlAHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerNationalOtherNo.No.SerialorHeatBoardIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)FLANGE-2"SA105FLANGE-2"SA105ELBOW-2"SA10590DEG.ELBOW-2"SA10590DEG.ELBOW-11/2"SA10590DEG.ELBOW-11/2"SA10590DEG.ELBOW-2"SA10545DEG.ELBOW-2"SA10545DEG.UNION-11/2"SA105UNION-11/2"SA105COUPLING-2"SA105COUPLING-2"SA105COUPLING-2"SA105COUPLING-2"SA105NIATIOGAPIPESUPPLYN/ATIOGAPIPESUPPLYN/ATIOGAPIPESUPPLYN/AHUB,INC.N/ATIOGAPIPESUPPLYN/ATIOGAPIPESUPPLYNIATIOGAPIPESUPPLYN/AHEAT&#xb9;8866369HT.&#xb9;R143S,8867888,8869827N/AHEAT&#xb9;R28CNIAHEAT&#xb9;MC-81NIAHEAT&#xb9;26215(NUT)28332NIAHEAT&#xb9;M46010N/AHT.CODE008JNIANIANIAN/AN/AN/AN/ANIANIAN/ANIAN/ANIAN/ANIAUTC377921'IR27412NIARIR&#xb9;29401,2K~46N/AUTC340391RIR2K-0195NIAUTC378122N/AUTC34272RIR2H-3441UTC380213RIR29401NIAUTC384011RIR33042NIA1995NIA1995NIA1995NIA1988N/A1993N/A1995NIA1995ReplacedReplacementReplacedReplacementReplacedReplacementReplacedReplacementReplacedReplacementReplacedReplacementReplacedReplacementNONONONONONONONO PSL-2,NIS-2TRACKINGNO.SL-2-8-31FORMNIS-2OWNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsofthcASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/19/95Sheet:4Unit:2of52.PlantSt.LucieNuclearPlantP.O.&#xb9;:N/APCM&#xb9;:096-2956501SouthHwy.AIAJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.,6501SAIAHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)REDUCER-11/2"SA105REDUCER-11/2"SA105N/ADUBOSENAT'LENR.N/AHEAT&#xb9;009GNIAN/AUTC372132RIR2D-7774N/AReplaced1995ReplacementNONOBAR,FlAT-A361/4"X8"BAR,FLAT-A361/4"X1/2"BAR,FLAT-A363"X1/2"INTERSTATESTEELHUBINC.INTERSTATESTEELHT.&#xb9;227640HT.&#xb9;G7511HT.&#xb9;16663N/ANIANIAUTC366048RIRR82-21911982ReplacementUTC378632RIR3AH-22351993ReplacementUTC365966RIRR82-15151982ReplacementNOBAR,FLAT-A364"X1/2"ENERGYSTEELHT&#xb9;642767N/AUTC372171RIR3AJ-14141994ReplacementBAR,FLAT-A3612"X1/2"BAR,FLAT-A36314"X21/2"ANGLE-A362"X2"X1/4"DUBOSENAT'LENR.INTERSTATESTEELDUBOSENAT'LENR.HT&#xb9;K34177HEAT&#xb9;25748HEAT&#xb9;J4710N/ANIANIAUTC378748RIR3AJ46661994ReplacementUTC365976-1RIR4R42581984ReplacementUTC372122RIR3AK46061995ReplacementNONONOANGLE-A363"X3"X1/4"ENERGYSTEELHEAT&#xb9;831674NIA'TC372126RIR3AK4238B1995ReplacementNORNDBAR-A361/2"FORU-BOLTU-BOLTA362"PIPESIZEDUBOSENAT'LENR.BERGENPATTERSONHEAT&#xb9;831674BPPART&#xb9;6510-2"NIAN/AUTC377719RIR3AJ-1369UTC378467RIR27761N/AReplacement1995ReplacementNONOU-BOLTA362"PIPESIZEBOLT,SA1935/8"-11UNC2ABERGENPATTERSONALLIEDNUTANDBOLTBPPART&#xb9;6510-2"HT.&#xb9;86240NIAN/AUTC372563RIR2H-19621993ReplacementUTC373880RIR3AF<7081992ReplacementNONO PSL-2,NIS-2TRACKINGNO.SL-2-8-31FORMNIS-2OWVNERSREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/19/95Sheet:5Unit:2of52.PlantSt.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957P.O.&#xb9;:N/APCM&#xb9;:096-2953.WorkPerformedBy:FloridaPower&LightCo.,6501SAIAHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)NUT,HEAVYHEXSA194GR.71/2"-13UNC2BALLIEDNUTANDBOLTHEAT&#xb9;8865606N/AUTC377946RIR2J-04231994ReplacementNONUT,HEAVYHEXA563GR.A3/8"-16UNC2BALLIEDNUTANDBOLTHEAT&#xb9;L04058N/AUTC371763RIR3AJ-12531994ReplacementNoNUT,HEAVYHEXSA194GR.75/8"-11UNC2BNUT,HEAVYHEXSA194GR.2H5/8"-11UNC2BNUT,HEAVYHEXSA194GR.2H5/8"-11UNC2BALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTHEAT&#xb9;L63812HEAT&#xb9;151603HEAT&#xb9;151603N/AN/AN/AUTC375497RIR25731UTC377897:RIR27358UTC372081RIR227631995Replacement1995Replacement1995ReplacementNONO PSL-1,NIS-2TRACKINGNO.SL-2<-~032FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miam,FL33152St.LucicNuclearPlant6501SouthHwy.AlAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V21693.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:Chemical&VolumeControlDate:12/4/95Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:009-293MPWO&#xb9;:3640WO&#xb9;:93017569CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEC.III;1971ED.-'73ADDENDUMCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentiTicationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)2'ISTONCHECKVALVE2'ISTONCHECKVALVEROCKWELLEDWARDANCHORDARLINGS/N:ET401938NASA182TP3161978NASA351;CF8M1993ReplacedReplacementCH104FW600CH104FW601FPLFPLWELDTRAV&#xb9;95-2324WELDTRAV&#xb9;95-2325NANASOCKETWELD(VALVE-PIPE)SOCKETWELD(VALVE-PIPE)1995ReplacementReplacement7.DescriptionofWork:REPLACEDVALVEANDASSOCIATEDWELDSCH-104-SW14&15ASPARTOFAMODIFICATIONTOCORRECTSEATLEAKAGEPROBLEMS.8.TestsConducted:HydrostaticXPneumaticNominalOperatingPressure(ISLT)Other:VT1XVT2XVT3~pstgTestTemp.~'P
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL Com          &#xb9;60 inspector's Signature                                      National Board, State, Providence and Endorsements Date        0            K          19 54


PSL-2,NIS-2TRACKINGNO.SL-2-8-032FORMNIS-2(Back)Sheet2of29.Remarks:NEWWELDSWEREEXAMINEDBYTHELIQUIDPENETRANTMETHODBYCERTIFIEDINSPECTORS.AHYDROSTATICTESTOFTHENEWASSEMBLYWASPERFORMED.NOLEAKAGEEVIDENT.10.InspectionReportNumbers:OSTHYDRORPT&#xb9;3640APPLICABLEMANUFACTURESoATAREPORTSTOBEATTACHEDCertiTicateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedGP*rrsOasignee,TitleDate&~19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.spector'sSignaturedMCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-33FORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/13/95Sheet:Iof3Unit:2P.O.f/:N/APCM0:058-295NPWO0:8234WO&#xb9;:95020553-01WCD&#xb9;:02204.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)(c)CodeClass:3COMPONENTCOOLING'A'UPPLYHD'R.1-8"<C<7TAGSB14628'A'ETURNHD'R.1-8"<C-50TAGSB14629'B'UPPLYHD'R.1-8'<C-53TAGSB14630'B'ETURNHD'R1-8"<C-54TAGSB14631TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearReplacedASMECodeBuiltRepairedorStampedReplacement(YorN)VALVE-6"SA516GR.70HENRYPRATTCO.SERIAL&#xb9;DD375-1-1N/AUTC380404RIR29783A'UPPLYHD'R1995MOD.VALVE-6"SA516GR.70HENRYPRATTCO.SERIAL&#xb9;DD375-1-3N/AUTC380406RIR297831995A'RETURNHD'RMOD.VALVE-6"SA516GR.70VALVE-6"SA516GR.70HENRYPRAYI'O.HENRYPRATTCO.SERIAL&#xb9;DD375-1-2SERIAL&#xb9;DD375-1AN/AN/AUTC380405RIR29783UTC380408RIR297831995B'RETURNHD'RMOD.B'UPPLYHD'R1995MOD.7.DESCRIPTIONOFWORK:PERMANENTMODIFICATIONTOSUPPLYA/CTOCONTAINMENTTOREDUCEMANREMIMANHOURSFORCONTAINMENTJOBS.8.TestConducted:Hydrostatic[X]Other.VT1[]VT2[X]Pneumatic[]VT3[]195NominalOperatingPressure(ISLT)[]PSIGTestTemp.sYsTEMFHoldTime10MINUTEs
PSL-1, NIS-2 TRACKING NO.               SL-2                         rP                        FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                               Florida Power & Light Co.               Date:      12/12/95 P.O. Box 529100                        Sheet:        I of Miami, FL 33152                                    i Unit:        2
: 2. Plant:                                 St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                  PCM&#xb9;: NA 3    Work Performed By'.                   Florida Power & Light Co.               PWO&#xb9;: 5075 6501 South Hwy. A1A WO &#xb9;:         95028673 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet: N/A
: 4. (a) Identification          of System:      Feedwater Type Code Symbol Stamp    N/A MV 09 14 Authorization No.        N/A (b) Component Identification:
(Mark Number)                                                                 Expiration Date          N/A (c) Code Class:               3 a) Applicable Construction Code and Addenda:                   ASME Sect lli 1989 Ed / No Add            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification          of Components    Repaired or Replaced and Replacement Components:
Type of                  Name of          Manufacturer    National      Other            Year      Replaced      ASME Component                Manufacturer        Serial or Heat  Board                          Built    Repaired      Code No.       No. Identification                    or        Stamped OI'aterial Replacement (Y or N) onnet        uts          aa icvave                                                                    ep ace 5/8 x11unc2B                                                                    GR7 onnet uts                Ie    ut    ot          eat no                        A 94                  ep acement 5/8 x11unc2B                                        L63812                      GR7 onnet tu s                aaic ave                                    A        AA9,3                  ep ace 5/8 x11unc2B                                                                  Gr B7 onne          u s              ova                eat o                                                ep acemen 5/8'   11unc 2B                                    62477                      Gr B7
: 7. Description of Work:               Replaced bolting due to corrosion.
: 8. Tests Conducted:               Hydrostatic               Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1           VT2         VT3                       psig    Test Temp.             'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-33FORMNIS-2(Back)Sheet2of9.RemarksAHYDROSTATICPRESSURETESTWASSUCCESSFULLYPERFORMEDONTHEWELDEDJOINTSANDWITNESSEDBYAVT-2CERTIFIEDQ.C.INSPECTOR.10.InspectionReportNumbers:M95-166FOR'A'EADERM95-070FOR'B'EADERAPPLICABLEMANUFACTURERSDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[]Replacement[X]ModificationconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwnesDesigee,TitleDate%(lR'5,19CERTIFICATEOFINSERVICEINSPECTION'\I,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-33FORMNIS-2OiVNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/13/95Sheet:3Unit:2of32.PlantSt.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957P.O.&#xb9;:N/APCM&#xb9;:058-2953.WorkPerformedBy:FloridaPower&LightCo.,6501SA1AHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)TEE8"X8"X6"SA234WPBFLANGE6"SA105TIOGAPIPESUPPLYTIOGAPIPESUPPLYHEAT&#xb9;N07397HEAT&#xb9;539TNTN/AN/AUTC381931RIR22806UTC371232RIR1790719951995A''B'D'RMOD.A''B'D'RMOD.NONOSTUD3/4"-1OUNC2ASA193GR.B7STUD3/4"-10UNC2ASA193GR.B7STUD3/4"-1OUNC2ASA193GR.B7NUT,HEAVYHEX3/4"-10UNC2BSA194GR.6ALLIEDNUT&BOLTALLIEDNUT&BOLTALLIEDNUT8BOLTALLIEDNUT&BOLTHEAT&#xb9;91521HEAT&#xb9;88147-GPHEAT&#xb9;51122HEAT&#xb9;N784DN/AN/AN/AN/ARIR1J-00911994RIR1J4I0431994UTC373362RIR227631995RIR1H-11001993A''B'D'RMODA''B'D'RMODA''B'D'RMODA''B'D'RMODNONO PSL-1,NIS-2TRACKINGNO.SL-2-8-34FPLFORMNIS-2OWIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/1I/95Sheet:Iof2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8214WO&#xb9;:95012906-01WCD&#xb9;0198(b)ComponentIdentification(MarkNumber)VARIABLESPRINGSUPPORTCC-2073-5314.(a)IdentificationofSystemCCWHX2A&2BTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:N/A(SUPPORT)5.(a)ApplicableConstructionCodeandAddenda:ANSIB31.11977ED.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1973Edition6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:N/ATypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearReplacedBuiltRepairedorReplacementASMECodeStamped(YorN)VARIABLESPRINGBERGENSUPPORT16VSPATTERSONPART&#xb9;BP-3100F-16N/AN/A1982REPLACEDNOVARIABLESPRINGBERGENSUPPORT16VSPATTERSONPART&#xb9;BP-3100F-16N/AUTC377925RIR273241995REPLACEMENT7.DESCRIPTIONOFWORK:DURINGINSPECTIONOFTHECCW,THESPRINGCANWASFOUNDTOBERUSTEDANDCORRODED.ENGINEERINGDETERMINEDTHATITSHOULDBEREPLACEDDURINGTHEREFUELINGOUTAGE.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)[]PSIGTestTemp.OFHoldTime
PSL-2, NIS-2 TRACKING NO.               SL-2                                                 FORM NIS-2 (Back)                                         Sheet 2 of      2
: 9. Remarks:          A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:       g~    t5  2-E~
APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                        +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                                                  Detect      '+ 19~
ne o Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board      of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
a /               Commissions Inspector's Signature                                    National Board, State, Providence and Endorsements
                                    , 19~


PSL-1,NIS-2TRACKINGNO.SL-2-8-34FORINNIS-2(Back)Sheet2of29.RemarksFINALASSEMBLYINSPECTIONWASSUCCESFULLYPERFORMEDBYAVT3CERTIFIEDQ.C.ISNPECTOR.10.InspectionReportNumbers:M95-464APPLICABLEMANUFACTURER'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwnei'seslge,TItleDate19ASCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwnei'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorproperty'damageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-35FPLFORMNIS-2OWIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/11/95Sheet:1of2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8212WO&#xb9;:95020723-01WCD&#xb9;0203'b)ComponentIdentification(MarkNumber)VARIABLESPRINGSUPPORTCC-2073-4414.(a)IdentificationofSystemCCWHX2A&2BTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:N/A(SUPPOR'Q5.(a)ApplicableConstructionCodeandAddenda:ANSIB31.11977ED.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1973EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)VARIABLESPRINGSUPPORT15VSVARIABLESPRINGSUPPORT15VSBERGENPATTERSONBERGENPATTERSONPART&#xb9;BP-3100F-15PART&#xb9;BP-3100F-15N/AN/AN/AUTC380514RIR2983119821995REPLACEDREPLACEMENTNO7.DESCRIPTIONOFWORK:DURINGINSPECTIONOFTHECCW,THESPRINGCANWASFOUNDTOBERUSTEDANDCORRODED.ENGINEERINGDETERMINEDTHATITSHOULDBEREPLACEDDURINGTHEREFUELINGOUTAGE.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)[]PSIGTestTemp.FHoldTime PSL-1,NIS-2TRACKINGNO.SL-2-8-35FORMNIS-2(Back)Sheet2of9.RemarksFINALASSEMBLYINSPECTIONWASSUCCESFULLYPERFORMEDBYAVT3CERTIFIEDQ.C.ISNPECTOR.10.InspectionReportNumbers:M95-121APPUCABLEMANUFACTURER'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/AsignedNk25ciwOwnersorOwneVSesige,TitleDate(21)l19ISCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwneVsReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDateL)~tf PSL-1,NIS-2TRACKINGNO.SL-2<-~636gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucioNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AlAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V24624.(a)IdentificationofSystem:Chemical8VolumeControlDate:12/1/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:009-293mPWO&#xb9;:3640WO&#xb9;:94025062CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESECTI.III,1971ED;SUMMER'73CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRcpaircdorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)2PISTONCHECKVALVEROCKWELLNASA182TP3161983Replaced2PISTONCHECKANCHORDARLINGVALVE8/NE-T401-9-16NASA351,CF8M1993Replacement2SCH160PIPEVALVE-PIPEWELDFW2000VALVE-PIPEWELDFW2001PIPE-TEEWELDFW-2002SANDVIKFPLFPLFPLHT&#xb9;468341WELDTRAV&#xb9;954225WELDTRAV&#xb9;954226WELDTRAV&#xb9;954471NANANAER308ER3081995ER308SA312,TP304NAReplacementReplacementReplacementReplacement7.DescriptionofWork:REPLACEVALVEDUETOSEATLEAKAGE.NEWWELDSADDEDFW2000,2001&2002S/NE-T401-9-168.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)Other.VT1XVT2XVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2<-~036FORMNIS-2(Back)Sheet2of29.Remarks:ALIQUIDPENETRANTEXAMANDHYDROSTATICTESTWASPERFORMEDOFALLWELDS.10.InspectionReportNumbers:OSTHydroRpt11/10/95APPLiCABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstothe'rulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/Asigned~~pibvrSLitov'Z,I0erorei'sDesignee,TitleDate,c.I19~SCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwneVsReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.nspectoVSSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate19~4.~
PSL-I, NIS-2 TRACKING NO.               SL-2                                             FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                         Florida Power & Light Co.               Date:     12/12/95 P.O. Box 529100                        Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3  Work Performed    By'lorida Power & Light Co.                          PWO&#xb9;: 5074 6501 South Hwy. A I A WO &#xb9;:       95028672 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet: N/A
: 4. (a) IdentificationofSystem:          Feedwater Type Code Symbol Stamp    N/A MV 09 13 Authorization No.       N/A (b) Component Identification:
(Mark Number)                                                              Expiration Date          N/A (c) Code Class:         3
    ) Applicable Construction Code and Addenda:             ASME Sect III 1989 Ed/No Add            Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components    Repaired or Replaced and Replacement Components:
Type of            Name of            Manufacturer    National      Other           Year      Replaced      ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired      Code or                                        No.         No. Identification                    of        Stamped Material                                                                                      Replacement (Y or N) onnet uts          aci ic a ve                                                                  ep ace 5/8' 11unc 2B                                                              GR7 onnet uts          ie    Ut    ot        eat no                                              ep acement 5/8' 11unc 2B                                L63812                      GR7 Bonnet tu s          Paciic a e                                                                      ep ace 5/8'  11unc 2B                                                          Gr B7 honnnet ate s            Nova                eat o                              93              ep acement 5/8 x11unc2B                                  62477                      Gr B7
: 7. Description of Work:       Replaced bolting due to corrosion.
: 8. Tests Conducted:         Hydrostatic               Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig    Test Temp.             'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-~83?~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35234.(a)IdentificationofSystem:SafetyInjectionDate:11/25/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:082-193MPWO&#xb9;:8994WO&#xb9;:94009303CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESECTIONIII;1974EDITIONCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedOl'eplacementASMECodeStamped(YorN)DISCASSMEMBLYTARGETROCKHEATIIIIG4041NASA479-TP3161983Replacement7.DescriptionofWork:REPLACEDISCASSEMBLYDUETOSEATLEAKAGE8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLTIXOther.VT1VT2XVT3~pstgTestTemp.~'P PSL-2,NtS-2TRADKtNGNO.SL-2-3-~037FORMNIS-2(Back)Sheet2of29.Remarks:Rs'eki3G&e-7ttwspsekohR)~bgVTR1i+@~10.InspectionReportNumbers:0+QG-Qg+APPUCABLEMANUFACTURESDATAREPORTSToBEATTAciiEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignednero~ei'sDesignee,TitleGoI/LG(Date~art2,19~5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspectoi'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate19' PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:11/29/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:082-193MPWO&#xb9;:7323WO&#xb9;:93018650CWO&#xb9;:NAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35514.(a)IdentificationofSystem:SafetyInjectionTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESectIII1974Ed/Sum75AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialscemAssemblyiscemAssemblyNameofManufacturerargetoargetoManufacturerSerialorHeatNo.00000352220NationalBoardNo.2288OtherIdentificationTP34749TP347YearBuiltReplacedRepairedofReplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replaceddisc/stemassemblyduetoseatleakage8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other.VT1VT2VT3~psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:PA~Q6ROE~APPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AAus<p<<w+sov.SignedneOwner'sDesignee,TitleDateQlvQ.tt199-'0CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignature>rCommissionsNationalBoard,State,ProvidenceandEndorsementsDate19is FORMN-2CERTIFICATEHOLDERS'ATAREPORTFORIDENTICALNUCLEARPARTSANDAPPURTENANCESeAeRequiredbytheProvisionsoftheASMECode,SectionlilNottoExceedOneDay'sProduction~gc~/4Pg.)of2.ManufacturedandcenlfledbyTaretRockCor.1966EBroadhollowRd;Farmingdale,NY11735(nameandaddressolIIPTCar(rica(aHo(derlFloridaPowerhLightCo.;FortPierce,FL349542.ManufacturedforInameandaddressotPurchase(ISt.LuciePlant;densenBeach,FL349573.Locationofinstallation(nameahdaddr~stlSA-479347204600-14.Type:(drawrnsno.l(matI.Soec.ho.l19745.ASMECode,SectionIII,Oivision1:(adrtronl6.FabricatedinaccordancewithConst.Spec.IOiv.2only)Disc7.Remarks:75ksi(tensilestrehethtSummer1975(addendadatalN/ARevision(no.lN/AIC(asstN/AICRNIOate1994(yearoualtlNone(CodeCaseno,lN/ASparepartforvalvemodelno.75C-023PartofStemAssembly,P/N200571-58.Nom.thickness(in.lMin.designthickness(in.lOia.IO(ft(ttin.l9.Whenapplicable,CertificateHolders'atsReportsareattachedforeachitemofthisreport:Lengthoverall(tt8(in.)(1)(2)(3)(4)(5)(6)l7)(8)(9){10)lIII(12)(13){14)(15)(16)(17)(I8)l19){20)(21)(22)l23)(24)l25)PartorAppurtenanceSerialNumberNANationalBoardNo.inNumericalOrderN/ANA(26)(27)(28)l29){30)(31)l32)(33){34)l35){36){37)(38)(39)(40)(41)(42){43)l44)(45)(46){47)(48){49)(50)PartorAppurtenanceSerialNumber~NationalBoardNo.inNumericalOrder10.OesignpressureF.Hydro.testpressureattemp.F~~~~~(wtwnaooacso(elAmbient'upplementalinformationintheformoflists.sketches,otdrawingsmaybeusedprovidedl1)sireis8))x11.I2)lnfotmationinitems2and3onthisoatsReponi~ktc(udedoneachsheet.I3)eachsheetisnumberedandthenumberofsheetsisrecordedatth~topofthisform.l12/88)Thisfohn(800040)maybeobtainedfromtheorderoept..AsM8.22Laworive.8ox2300.Faitfie(d.NJ07007.2300.Reprintpig1)
PSL-2, NIS-2 TRACKING NO.               SL-2                                                   FORII NIS-2 (Back)                                       Sheet 2 of      2
PSL-1,NiS-2TRACKtNGNO.SL-2-8-~039gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miam,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2MV-08-1B3.WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:11/25/95Sheet:-1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4906WO&#xb9;:95025620CWO&#xb9;:NAProcessSheet:N/A,TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialSEALWELDFW-2001NameofManufacturerFPLManufacturerSerialorHeatNo.WELDTRAV.&#xb9;954246NationalBoardNo.sNAOtherIdentificationSA-105YearBuiltReplacedRepairedorReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:REMOVE/REPLACESEALWELDTOFACILITATEVALVEREPAIR8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressurettSLT)XOther.VT1VT2XVT3~psigTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-039FORMNIS-2(Back)Sheet2of29.Remarks:QQsska&r"WQtrtst-'re.'crhQrt>for4'skia/ra~%5p.rrttt)rtsse8~d~IkcsseZQaV~gC~r4F~810.InspectionReportNumbers:Iti/iiQ$QgQgAPPUCABLEMANUFACTURESDATAREPORTSToBEATTACKEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSRISv/v-ISIeorer'sDesignee,TitleDatekv?Sta'rr.CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDaterh195i PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentiTication:(MarkNumber)(c)CodeClass:2V82114.(a)IdentificationofSystem:MainSteamDate:12/2/95Sllect'ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:1122WO&#xb9;:CWO&#xb9;:95019529IANAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectionIII1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialnetus13/8x8unc2Anettus13/8'8unc2Anetus13/8x8unc2Bnetuts13/8'8unc2BNameofManufacturerawovaMacneawAieutotManufacturerSerialorHeatNo.eato8868243/92397eatoQ2293ANationalBoardNo.OtherIdentificationGrB7A193GrB74Gr2H4Gr7YearBuiltReplacedRepairedofReplacementepaceepacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedinletflangeboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.
: 9. Remarks:         A satisfactory inservlce leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:       PRM 9S - ZS 8'5 APPLiCABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +   Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed        /''wn r or Owner's Designee, Title Date  ~(., 9~         1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
c aLd Commissions Inspector's Signature                                      National Board, State, Providence and Endorsements


PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:f8&#xc3;g5c2lItAPPLiCABLEMANUFACTURE'SDATAREPORTSTOBEATl'ACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedJ~MP~~(GRr-lGIOwnerrOwner'sDesignee,TitleDt~t,19~+CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleC3startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate
PSL-1, NIS-2 TRACKING NO.             SL-2                                               FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI
: l. Owner:                          Florida Power & Light Co.               Date:     11/29/95 P.O. Box 529100                          Sheet:    1  of Miami, FL 33152 Unit:      2
: 2. Plant:                             St. Lucie Nuclear Plant 6501. South Hwy. AIA                      P.O.&#xb9;:    NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By;            'lorida Power & Light Co.                      PWO&#xb9;: 2305 6501 South Hwy. A1A WO &#xb9;:      95000522 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:      N/A
: 4. (a) Identification    of System:       Chemical 8 Volume Control Type Code Symbol Stamp          N/A V2500 Authorization No.               N/A (b) Component Identification:                                                                         Expiration Date                N/A (Mark Number)
(c) Code Class:      2 (a) Applicable Construction Code and Addenda:              ASME Sect III 1989 Edition/No Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components      Repaired or Replaced and Replacement Components:
Type of              Name of            Manufacturer      National      Other          Year      Replaced            ASME Component          Manufacturer          Serial or Heat    Board                        Built    Repaired            Code or                                        No.        No. Identification                                  Stamped OI'eplacement Material (Y or N) ange  ut                  aw                                                                    ep ace 5/8 x11unc28                                                              Gr2H ange  ut          le    ut    ot        ea    o                            94               ep acement 5/8 x11unc28                                  L63812                      GR 7"'
ange tu                      aw                                          ESKi05                    ep ace 5/8 x11unc2A                                                              Gr 87 ange u              ova    a  ine          ea    o                                            Rep acement 5/8 x11unc2A                                  8099572                      Gr 87
: 7. Description of Work:          Replaced flange bolting due to corrosion.
: 8. Tests Conducted:          Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1            VT2
                                                              ~      VT3                      psig    Test Temp.                   'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573WorkPerformedBy.'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/12/95Sheet:1pfUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2499WO&#xb9;:95003094CWO&#xb9;:ProcessSheet:N/A4.(a)IdentificationofSystem:MainSteam(b)ComponentIdentification:V8213(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:2)APPlicableConstructionCodeandAddenda:ASMESectIII1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialnetangetu13/8xSun2Anetangetu13/8xSun2Anetangeut13/8'8un2Bnetangeut13/8xSun2BNameofManufacturerawovaawIieutotManufacturerSerialorHeatNo.eato8868243/92397eatoQ2293ANationalBoardNo.OtherIdentificationGrB788~93GrB7Gr2HGr7YearBuiltReplacedASMERepairedCpdeOfStampedReplacement(YorN)epaceepacementepaceepacement7.DescriptionofWork:Replacedinletflangeboltingduetocorrosion8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3~pslgTestTemp.'F
PSL-2, NIS-2 TRACKING NO.                 SL                                                   FORM NIS-2 (Back)                                         Sheet 2 of      2
.
: 9. Remarks:         A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:fr<rei"-Ig-IG85APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertiTicateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedA.ne-v'-l<lOwnrrOwner'sDesignee,TitleDateMCI319~5'CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethatto,thebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwnei'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageortossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-2-FPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/5/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:1122WO&#xb9;:CWO&#xb9;:950195301ANAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V82074.(a)IdentificationofSystem:MainSteamTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectlii1989Edition/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialunet13/8'x8unc2ANameofManufacturerawManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationGr87YearBuiltReplacedRepairedorReplacementepaceASMECodeStampedPorN)tunet13/8x8unc2Autnet13/8x8unc28utnet13/8x8unc28ovaSPS2awAheutoteato8868243/92397eatoQ2293AGr87Gr7Gr79319494epacementepaceepacement7.DescriptionofWork:Replacedinletflangebolting8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.
: 10. Inspection Report Numbers:         fYl MO,Q      -X3 lQ, APPLiCABLE MANUFACTURE'S DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
PSL-2,NIS-2TRACKINGNO.SL-2-2-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:&#x17d;WGlic2-i~~APPLiCASLEMANUFACTuRE'SDATAREPORTSToSEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedGkarRIiWMIN(nrornr'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,Nls-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&,LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V82013WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:11/27/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5002WO&#xb9;:CWO&#xb9;:950285091ANAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1989Edition/noaddendaCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialuneange13/8x8unc2Aunetange13/8x8unc2Autnetange13/8x8unc2Butnetange13/8xaunc2BNameofManufacturerawieuotawieuotManufacturerSerialorHeatNo.eatos8868243/92397eato02293ANationalBoardNo.OtherIdentificationGrB7ESK705GrB794Gr2HGr7YearBuiltReplacedRepairedorReplacementepaceepacementepaceepacemenASMECodeStamped(YorN)7.DescriptionofWork:Replacedinletbolting.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3~pslgTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:N/tnI6APPLICABLEMANUFACTuRE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAthorizationNo.:N/ASignedoGe(.WSuW5DtQOV~,19'KOwneOwesDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.tnspectoi'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDateILiOV'>,19~5 PSL-1,NIS-2TRACKINGNO.SL-2-8-IFORMNIS-2OiVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:V8208(MarkNumber)(c)CodeClass:23WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:12/12/95Sheet:IofUnit:P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2511WO&#xb9;:CWO&#xb9;:950028501ANAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialnetangetu13/8x8un2ANameofManufacturerawManufacturerSerialorHeatNo.NationalBoardNo.AOtheridentificationGrB7YearBuiltReplacedRepairedorReplacementepaceASMECodeStamped(YorN)netangetu13/8x8un2Anetangeut13/8x8un2Blnletangeu13/8x8un2BovaawieUtoteato8868243/92397eatoQ2293AAGrB7Gr2HGr79394Repacementepaceepacemen7.DescriptionofWork:Replacedinletflangeboltingduetocorrosion8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT.3psigTestTemp.LF
Repair
                                                                                                            +   Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                                                      Dele  ~~4~) ebe e    19~7 ner or    ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
                    .)
Commissions inspector's Signature                                        National Board, State, Providence and Endorsements Date


PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPLICABLEMANUFACTURE'SDATAREPORTSTOBEATfACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSriPCASoot/-ISnrOwner'sDesignee,TitleCeIe~llZ,Ie'RSCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleP8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-45FORMNIS-2OiVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsoftheASMECodeSectionXI1.Owner-2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/18/95Sheet:1of3Unit:2P.O.&#xb9;:N/APCM&#xb9;:016-290NPWO&#xb9;:8882WO&#xb9;:95024868-01WCD&#xb9;:02424.(a)IdentificationofSystemCCWHEATEXCHANGER(b)ComponentIdentification2ASHELLSIDEDRAIN(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:'b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearReplacedBuiltRepairedorReplacementASMECodeStamped(YorN)FLANGE"S/0SA105150&#xb9;PIPE-6"SA106GR.BFLANGE%"BLSA105&#xb9;TIOGAPIPESUPPLYTIOGAPIPESUPPLYTIOGAPIPESUPPLYHEAT&#xb9;8861721HEAT&#xb9;33366HEAT&#xb9;8079587N/AN/AN/AUTC380442RIR29303RIR3RB-1677UTC3825939RIR316171995199019952AHXDRAINMOD.2AHXDRAINMOD.2AHXDRAINMOD.NO7.DESCRIPTIONOFWORK:EXISTINGDRAINSWEREDEGRADEDANDINEFFECTIVE.MODIFICATIONWASCOMPLETEDTOINCREASEEFFECTIVENESS.8.TestConducted:Hydrostatic[X]Other:VT1[]VT2[X]Pneumatic[]VT3[]165NominalOperatingPressure(ISLT)[]PSIGTestTemp.SYSTEMFHoldTime10MINUTEs PSL-1,NIS-2TRACKINGNO.SL-2-8-45FORMNIS-2(Back)Sheet2of9.RemarksAHYDRosTATIGPREssURETEsTwAssuccEssFULLYPERFQRMEDQNTHEWELDEDJOINTSANDWITNESSEDBYAVT-2CERTIFIEDQ.C.INSPECTOR.10.InspectionReportNumbers:.M95-307APPLICABLEMANUFACTURERSDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[]Replacement[X)ModificationconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/AOwnersorOwnSDesnse,TitleDateDe<~4,19~SCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleP8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate xl PSL-2,NIS-2TRACKINGNO.SL-2-8-45FORMNIS-2OWNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.,OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/13/95Sheet:3Unit:2of32.PlantSt.LucieNuclearPlantP.O.8:N/APCM&#xb9;:016-2906501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.,6501SA1AHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)STUD3/4"10UNC2ASA193GR.B7NUT,HEAVYHEX3/4"10UNC28SA194GR.2HALLIEDNUTANDBOLTALLIEDNUTANDBOLTHEAT&#xb9;51122HEAT&#xb9;E04277N/AN/AUTC375495RIR257311995RIR1H-110019952AHXDRAINMOD.2AHXDRAINMOD.NO PSL-1,NIS-2TRACKINGNO.SL-2-8-46PPLFORMIi/IS-2OWIAVERSREPORTFORREPAIRSORREPLACEMEiITSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:4.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957INTAKECOOLINGWATERVALVEV-21165Date:II/13/95Sheet:Iof2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:7706WO&#xb9;:95013850-01WCD&#xb9;:0184TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:5.(a)ApplicableConstructionCodeandAddenda:ASME1977S1977ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.Identi6cationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNUT,HEAVYHEX11/2"%UN2BNUT,HEAVYHEX11/2"%UN2BNUT,HEAVYHEX11/2"%UN2BNameofManufacturerALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTManufacturerSerialorHeatNo.Q2293AQ2293ANationalBoardNo.OtherIdentificationRIR2J-1002SA194GR.7RIR26598SA194GR.7RIR2H4253SA194GR.7YearBuilt1993ReplacedRepairedorReplacementREPlACEMENTREPLACEMENTREPLACEMENTASMECodeStamped(YorN)NONONONUT,HEAVYHEX11/2"NUN2BBOLT,STUD11/2"4UNX61/2"ALLIEDNUTANDBOLTALLIEDNUTANDBOLTQ2293A52869-FCN/ARIR2J-1243SA194GR.7RIR26597SA193GR.B71995REPIACEMENTREPlACEMENTNONO7.DESCRIPTIONOFWORK:BOLTINGWASWORNDUETONORMALWEARANDTEARANDFPLRECOMMENDEDREPlACEMENT8.TestConducted:Kydrostatic[]Other.VT1[]VT2[X]Pneumatic[]VT3[]NominalOperatingPressure(ISLT)[X]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-46FORMNIS-2(Back)Sheet2of9.RemarksIsLTwAssATIsFAGToRILYPERFQMEDoNYALYEsB-2116510.InspectionReportNumbers:M95-308APPLICABLEMNrUFACTURER'SOATAREPORTSToBEATTACIKDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[)RepairfX)ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorsDenee,TIUeDateLLCERTIFICATEOFINSERVlCEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBo6erandPressureVesselinspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescnbeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywananty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate
PSL-1, NIS-2 TRACKING NO.             SL-2                                                 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                           Florida Power & Light Co.               Date:       11/29/95 P.O. Box 529100                          Sheet:      1  of  3 Miami, FL 33152 Unit:      2
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM &#xb9;: 009-293M
: 3. Work Performed By:                   Florida Power  & Light Co.               PWO&#xb9;: 4092 6501 South Hwy. A1A WO &#xb9;:       95012783 Jensen Beach, FL 34957 CWO      &#xb9;: NA        Process Sheet: N/A
: 4. (a) Identification    of System:       Chemical & Volume Control Type Code Symbol Stamp      N/A Authorization No.        N/A (b) Component                        V2551 Identification:                                                                         Expiration Date          N/A (Mark Number)
(c) Code Class:     3 (a) Applicable Construction Code and Addenda:                 ASME Sect III 1986 Ed / No Add.         Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components      Repaired or Replaced and Replacement Components:
Type of              Name of            Manufacturer      National      Other          Year      Replaced        ASME Component          Manufacturer          Serial or Heat    Board                        Built    Repaired        Code or                                        No.         No. Identification                    or        Stamped Material                                                                                        Replacement (Y or N) ave    ssem  y            arway                                                                      ep ace 2'lobe                                                              GR F316 ave    ssem  y      n    or a ing          ena    o                                    993    Rep acement 2 Globe                                SN-E-T516-74                  GR F316 Ipe                      aw                                                                    ep ace 2 Sch 80                                                              316 TP304 Ipe                ioga ipe              eat o                        ESA 376                ep acement 2 Sch 80            Kobe Steel            V40407                      TP 304 2000                  e    rave er            021                        i er                  ep acement Socket Weld              95-3574                                        ER 308 2                    e    rave er                                        i er                  ep acement Socket Weld              95-3573                                        ER 308
: 7. Description of Work:        REPLACE 2" CHECK AS PART OF VALVE UPGRADE. EXISTING WELDS REPLACED.
: 8. Tests Conducted:           Hydrostatic Other: VT1           VT2~
Pneumatic VT3
                                                                                            ~
Nominal Operating Pressure (ISLT) psig  Test Temp.               'F


PSL-1~NIS-2TRACKINGNO.SL-2-8-47FORiMNIS-2OIVlAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:11/13/95Sheet:Iof2Unit:2P.O.&#xb9;:N/APCM&#xb9;:129-295NPWO&#xb9;:8779WO&#xb9;:95024463-01WCD&#xb9;:0236TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A4.(a)IdentificationofSystemINTAKECOOLINGWATER(b)ComponentIdentificationLINEI-24"-CW-75(MarkNumber)24"ELBOW(VALVESIDE)ICW"A"HEADER(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1977S1977ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialBOLT,STUD'11/4"WX51/2BOLT,STUD11/4"WUN2AX13CUTFROMRODNUT,H.HEX11/4"WUN2BNameofManufacturerALLIEDNUT&BOLTALLIEDNUT&BOLTALLIEDNUT&BOLTManufacturerSerialorHeatNo.M5371662413E97187NationalBoardNo.N/AOtherIdentificationUTC378384SA193GR.B7RIR27708UTC379705SA193GR.B7RIR2J<232UTC333268SA194GR.2HRIR2J<761ReplacedRepairedorReplacementREPLACEMENTREPLACEMENTREPlACEMENTASMECodeStamped(YorN)NONONO7.DESCRIPTIONOFWORK:STUDSANDNUTSWEREREPLACEDBECAUSETHEYWERENICKEDANDWORNDUETONORMALWEARANDTEAR.8.TestConducted:Hydrostatic[]Other.VT1[]VT2[X]Pneumatic[]VT3[]NominalOperatingPressure(ISLT)[X]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HDURs
PSL-2, NIS-2 TRACKING NO.               SL                                                   FORM NIS-2 (Back)                                      Sheet 2 of      3
: 9. Remarks:         A satisfactory hydrostatic test was performed and witnessed by a VT-2 certified inspector D5~      W~>        O<P@~              4                            QIX B
: 10. Inspection Report Numbers:
APPLICABLE MANuFACTURFS DATAREPORTS To BE ATTACHED Certificat of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                        +    Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner or    ner's Designee, Title Cate ~gigV          . Ig~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desoibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectols Signature                                      National Board, State, Providence and Endorsements Date        6                      . 19~<


PSL-1,NIS-2TRACKINGNO.SL-2-8-47FORNINIS-2(Back)Sheet2of9.RemarksISLTWASSATISFACTORILYPERFOMEDFORTHEFLANGETOVALVECONNECTIONATVALVEI-MV-21-3.10.InspectionReportNumbers:M95-306APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedW~WOwnersorer'signee,TiUeDate('LIIS19~XCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngineeringAssociateshaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmyknowledgeandbelief,theOvmerhasperformedexaminationsandtakencorrectivemeasuresdescnbeinthisOwner'sReportinaccordanceviiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.Bysigningthiscertificateneithertheinspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2>>8-48FORMNIS-2OWIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsofthcASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/18/95Sheet:Iof2Unit:2P.O.&#xb9;:N/APCMff:N/ANPWO&#xb9;:8210WO&#xb9;:95012782-01WCD&#xb9;:01954.(a)IdentificationofSystemINTAKECOOLING(b)ComponentIdentificationSB21163(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)BOLT,SA193GR.B711/4"-SUN2AX7"BOLT,SA193GR.B711/4"SUN2AX20NUT,HEAVYHEXSA194GR.2H11/4-8UN2BNOVAMACHINENOVAMACHINEALLIEDNUTANDBOLTCO.HEAT&#xb9;79916HEAT&#xb9;M51481HEAT&#xb9;151593N/AN/AN/AUTC341998RIR3J-10521994UTC341991RIR3J-1052B1994UTC374489RIR247421995ReplacementReplacementReplacementNONONO7.DESCRIPTIONOFWORK:BOLTINGATVALVE21163REPLACEDBECAUSEOFNORMALWEARANDTEAR8.TestConducted:Hydrostatic[]Pneumatic[]NominalOperatingPressure(ISLT)[X]Other:VT1[]VT2[X]VT3[]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8--59FORMNIS-2(Back)Sheet2of9.RemarksANIsLTwAssUGGEssFULLYPERFQRMEDQNTHEFLANGEDCONNECTIONSANDWITNESSEDBYACERTIFIEDQ.C.INSPECTOR10.InspectionReportNumbers:M95-302APPLICABLEMANUFACTURER'SOATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]RepairtX]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwnsDBInee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVessel,InspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate
PSL-I, NIS-2 TRACKING NO.           SL-2                                   FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PL                                SUPPLEMENTAL SHEET
: 1. Owner:               Florida Power & Light Co.               Date:       4j22Jg4 P.O. Box 529100 Miami, FL 33152                    Sheet:           3 of    3
: 2. Plant:               St. Lucie Plant                  Unit &#xb9;:             2 6501 South Hwy. A1A Jensen Beach, FL 34957            P.O.  &#xb9;:           NA
: 3. Work Performed By: Florida Power & Light Co.               PCM &#xb9;:          009-293M 6501 South Hwy. A1A
: 6. Identification of Components  Repaired or Replaced and Replacement Components:
National                            Replaced      ASME Name of          Name of          Manufacturer                    Other         Year Serial or Heat    Board                              Repaired      Code Component          Manufacturer                                    Identification  Built No.         No.                                   or      Stamped Replacement  PorN) e    rave er                                  i er                    ep acemen Socket Weld          95-3572


PSL-1,NIS-2TRACKINGNO.SL-2-8-FPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsoftheASMECodeSectionXII.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:SS-21-1A(MarkNumber)(c)CodeClass:33.WorkPerformedBy:FloridaPowerEr,LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ComponentCoolingWaterDate:12/13/95Sheet:IofUnit:P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3572WO&#xb9;:95001866CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESectlli/1989EdNoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialus1-Suncx7"~ius1-Suncx7NameofManufacturerumIndustriesovaMachineManufacturerSerialorHeatNo.eatoS090323NationalBoardNo.OtherIdentification193GrB7193GrB7YearBuiltReplacedRepairedorReplacementepaceepacementASMECodeStamped(YorN)7.'escriptionofWork:Replacedstrainerstudsduetonormalcorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3~psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-13958MM95-1918APPLICABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSPV/L/-l5neronei'sDesignee,TitleDate~l(819~7,CERTIFICATEOF.INSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleP8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate/3,19~
FORM NPV-1 CERT1FICATE                  HOLDERS'ATA REPORT                    FOR NUCLEAR PUMPS OR VALVES As Required by the Provisions of the ASME Cade. Section ill. Division                                  1 Pg.           of I. Manufactured and certified by        Anchor/Darl ing            Va 1 ve      Co., 701        First Street,              Wi 1 1 i amsport,    PA 17 (name snd sddtess ot N Cenificste Hoidetl M      f      d  f, Fl ori da      Poive  r  iz Li qht    Co  .,  P . 0. Bo'x    029950, Mi ami, FL (name sna aadress ot Purcnsser or awnerl 33102-9950 3  .,,..,St.Lucie Plants,                            6501 South A1A, Jensen                        Beach, FL          34957 Iname sna aaatessl Gb                                                                                            N/A
: 4. Model No.. Series No., or Type                                orawing W93239                      Rev.                        cRN
: 5. ASME Code. Section ill, Division          I:       1986 (edioonl            Ieadenaa aatel                  (cfassr              (Code Case no.l Val ve B. Pump or valve                                Nominal inlet size                              Outlet size (In.l                                    (in.l
: 7. Material:     Body                            Bonnet                                                                            N A lal                            ib)                          lc)                              ld)                           Iel Cert.                         Nat'I                        Body                          Bonnet                          Disk Holder's                        Board                        Serial                          Serial                        Serial Serial No.                        No.                          No.                            No.                            No.
E-T516-       -4                                                                                                          MT.&#xb9;34735
'uooiementa( informahon in form of lists. sketches. or drawings msv be used oroinasd        (ll size is 8yi x 11. I2) infonnaoon in items I through 4 on this asia Reoott ts inciuaaa on escn shear. (3) each sneet is numoerea snd the number Of Sheets is recoraad st the top at this form.
(12/86I                      This form (6000371msv be obtained tram the atder aeot.. ASME. 22        taw arive. 8ox 2300. Fsirfield. NJ 07007-2300.


PSL-1,NIS-2TRACKINGNO.SL-2-8-50FORMNIS-2OWVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:01/18/96Sheet:Iof4Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8218WO&#xb9;:95012801-03&04WCD&#xb9;:0188,189,&01904.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)(c)CodeClass:INTAKECOOLINGWATERLINEI-30-CW-20SPOOL14ZiV-68-IEc2EL1-30"-CW-77-2ELI-30CiV-76-2TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXlforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNUT,HH-SA-19411/4"-8UN2BBOLT,SA19311/4"4UN2AX9"BOLT,SA19311/4"-8UN2AX9"NUT,HH-SA-19411/4"-8UN2BNameofManufacturerALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIED,NUTANDBOLTALLIED,NUTANDBOLTManufacturerSerialorHeatNo.HEAT&#xb9;E97187HEAT&#xb9;8894177HEAT&#xb9;70251HEAT&#xb9;151593NationalBoardNo.N/AN/AN/AN/AOtherIdentificationUTC333268RIR2J-0761UTC373936RIR24401UTC331564RIR3J-0190UTC374489RIR24742YearReplacedBuiltRepairedorReplacement1994REPLACEMENT1995REPLACEMENT1994REPLACEMENT1994REPLACEMENTASMECodeStamped(YorN)NONONO7.DESCRIPTIONOFWORK:MATERIALSWORNDUETONORMALWORN,TEARANDCORROSION.FPLRECOMMENDATIONTOREPLACE8.TestConducted:Hydrostatic[]Other:VT1f]VT2[X]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)[X]SYSTEMPSIGTestTemp.SYSTEMFHoldTime4HoURs PSL-1,NIS-2TRACKINGNO.SL-2-8-50FORMNIS-2(Back)Sheet2of49.RemarksISLTWASSATISFACTORILYPERFORMEDFORTHEFLANGEDCONNECTIONS.FINALINSPECTIONWASPERFORMEDFORSUPPORTBYAVT3CERTIFIEDINSPECTOR.10.InspectionReportNumbers:M95-411,M95452,8M95-454APPLICABLEMANUFACTURER'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]RepairfX]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizatiNoN/ASignednersorOwner'sDesignee,TitleDateCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.'BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-50FORMNIS-2OWNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:01/18/96Sheet:3Unit:2of42.PlantSt.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957P.O.I/:N/APCM&#xb9;:N/A3.WorkPerformedBy:FloridaPower&LightCo.,6501SAIAHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)BOLT-SA1935/8"-11UNC2ANUT,HH-SA19411/4"-8UN2BNUT,HH-SA19411/8"4UN2BNOVAMACHINEALLIEDNUTANDBOLTALLIEDNUTANDBOLTHEAT&#xb9;6R-59444HEAT&#xb9;151593HEAT&#xb9;152550NIANIANIAUTC375439RIR25175UTC374489RIR24742UTC374486RIR247421995Replacement1995ReplacementNIAReplacementNONONOU-BOLTA36WIA563GR.ANUT21/2"PIPESIZENUT,HH-SA1945/8"-11UNC2BBOLT-SA1935/8"-11UNC2ABERGENPATIERSONALLIEDNUTANDBOLTNOVAMACHINEU-BOLTHT.&#xb9;8096325NUTS-3D589HEAT&#xb9;L63812HEAT&#xb9;62477NIAN/AUTC375497RIR257311995ReplacementRIR1J41991994ReplacementUTC373874RIR3AH43751993ReplacementNONOBOLT-SA1935/8"-11UNC2ABOLT-SA1935/8"-11UNC2ABOLT-SA1935/8"-11UNC2ABOLT-SA1935/8"-11UNC2ANOVAMACHINENOVAMACHINEALLIEDNUTANDBOLTALLIEDNUTANDBOLTHEAT&#xb9;62477HEAT&#xb9;6R-59444HEAT&#xb9;88147-GPHEAT&#xb9;88147-GPN/AN/AN/AN/AUTC372561RIR1J4224UTC375439RIR25175UTC372557RIR1J-0247UTC374493RIR247421994Replacement1995Replacement1994Replacement1995ReplacementNONONONOBOLT-SA19311/4"-8UNC2ABOLT-SA19311/4"-8UNC2ABOLT-SA19311/4"-8UNC2AALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTHEAT&#xb9;70251HEAT&#xb9;8078593HEAT&#xb9;62480N/ANIANIAUTC331566RIR3J-0190B1994ReplacementUTC331565RIR3J-0190A1994ReplacementUTC331567RIR3J4190B1994ReplacementNONO PSL-2,NIS-2TRACKINGNO.SL-2-8-50FPLFORMNIS-2OWNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:01/18/96Sheet:4Unit:2of42.PlantSt.LucieNuclearPlantP.O.&#xb9;:N/APCM&#xb9;:N/A6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.,6501SA1AHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)FLANGE,4"SA105FlANGE,4"SA105PIPET,30"X4"SA234N/ATIOGAPIPEN/AN/AHEAT&#xb9;8860283NIAN/AN/ANIAN/AUTC378328RIR27287NIAN/AReplaced1995ReplacementNIAReplacedNONONOPIPET,30"X4"SA234TIOGAPIPEHEATCODE71N/ARIR2J42921994ReplacementNOSUPPORTCW-3001437A36(ANGLE)NIANIAN/AN/AN/AReplacedANGLE,A363"X3"X3/8"DUBOSENATIONALENERGYHEAT&#xb9;J5966N/AUTC369804RIR3AK46061995ReplacementSUPPORTCW-3001437A36(ANGLE)N/ANIANIANIAN/AReplacedANGLE,A3611/2"X11/2"X1/4"DUBOSENATIONALENERGYHEAT&#xb9;J2705NIAUTC370160RIR3AK46171995ReplacementNO
PSL-1, NIS-2 TRACKING NO. S            L-2         97 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                                Florida Power & Light Co.
P. O. Box 529100 Miami, FL 33152 Date: 02/01/96 Sheet:
Unit: 2 1
                                                                                                        'f      2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. &#xb9;: N/A 6501 South Hwy. A1A                          PCM &#xb9;: N/A Jensen Beach, FL 34957                      NPWO &#xb9;: 8218
: 3. Work Performed By:                   Florida Power  & Light Co.                    WO &#xb9;: 95032001-1A 6501 South Hwy. A1A                            WCD N/A Jensen Beach, FL 34957
: 4. (a) Identification of System        CCW                                        Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        SUPPORT CW-3002-152                                    Expiration Date N/A (Mark Number)
(c) Code Class:     N/A (SUPPORT FOR CLASS 3 SYSTEM)
: 5. (a) Applicable Construction Code and Addenda:          ANSI B31.1       1977 ED. Code Case:             N/A (b) Applicable Edition of Section XI for Repairs and Replacement    Components:     1973  Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer      National        Other        Year      Replaced      ASME Code Component or        Manufacturer    Serial  or Heat    Board      Identification Built Repaired or          Stamped Material                            'No.           No.                                 Replacement      (Y or N)
      'ANGLE - A36 5" X 5" X 3/8"         N/A              NIA          NIA                        NIA      REPLACED ANGLE A36                            HEAT  &#xb9;                   UTC  381833 5" X 5" X 3/8"     HUB INC.           89180          N/A        RIR 4R4590      1985 REPLACEMENT ANGLE - A36 3" X 3" X 1/4"         N/A              NIA          NIA            N/A        NIA      REPLACED          NO ANGLE - A36      INTERSTATE                                    UTC 379177 3" X 3" X 1/4"       STEEL            F7116          N/A      RIR 4R-2876      1983 REPLACEMENT            NO
: 7. DESCRIPTION OF WORK:                VALVEI-TCV-144B, VALVE EXTENSION STEM        WAS    MISALIGNED  TO VALVE DUE TO AN ORIGINAL INSTALLATIONPROBLEM. THE ENTIRE SUPPORT NEEDED TO BE MOVED TO ALLOWVALVESTEM REALIGNMENT.
8.. Test Conducted:         Hydrostatic []                Pneumatic    []                  Nominal Operating Pressure (ISLT) []
Other: VT1 []            VT2[]            VT3 [X]                        PSIG      Test Temp.                 F Hold Time


PSL-QNIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1PCV-1100F4.(a)IdentificationofSystem:ReactorCoolantDate:11/29/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3601WO&#xb9;:95001741CWO&#xb9;:ProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1971Ed/W72Add.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentof"MaterialugstemAssemblyugstemAssemblyNameofManufactureriserontrosiserontrosManufacturerSerialorHeatNo.eato99911-1NationalBoardNo.AOtherIdentification4Typ31649Typ316YearBuilt199ReplacedRepairedofReplacementepaceReplacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedplugandstemassemblyduetonormalwear.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.RemarksAsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:cfQAPPLicABLEMANUFACTURE'SDATAREPORTSTOBEATl'ACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairQReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AsignedkA'eGSndnn5vnvOwnrOwner'sDesignee,TitleDate~0~+7,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,the'OwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-52FORMNIS-2OYVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/07/95Sheet:Iof2Unit:2P.O.&#xb9;:C92933-90719PCM&#xb9;:N/ANPWO&#xb9;:8234WO&#xb9;:95028726-01WCD&#xb9;:'N/A4.(a)IdentificationofSystemCCWSUPPLYHEADER(b)ComponentIdentificationVALVESB14528(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1974S1974ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)VALVE-10"VALVE-10"HENRYPRATTCO.HENRYPRATrCO.D0065-2-1DD74-1-1N/AN/ASA516GR.70UTC383726SA516GR.70RIR3H-0911AN/A1993REPLACEDREPLACEMENTYESYES7.DESCRIPTIONOFWORK:PLANTWASUNABLETOTIE-INPERPCM058-295(PERM.CONT.A/C)VALVEWASLEAKINGATTHESEATATARATEOF2GAL.PERMINUTE.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]VT3[]NominaIOperatingPressure(ISLT)[X]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-52FORMNIS-2(Back)Sheet2of9.RemarksISLTFORTHEFIANGEDCONNECTIONSONVALVESB-14528WASSATISFACTORILYPERFORMED.10.InspectionReportNumbers:M95-467APPUCABLEMANUFACTURERSDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]RepairfX]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:NIACertificateofAuthorizationNoN/AOwnersorOwner'sDigneeIeDate>2I7,ttt~f.CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleff8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsand'takencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageortossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate196V
PSL-1, NIS-2 TRACKING NO. S L 8 -               97 FORM NIS-2           (Back)                   Sheet  2   of
)pgQ-otIIPage<ot~(FORMNPV-1CERTIFICATEHOLDERS'ATAREPORTS-0RPUMPSORVALVESAsRequiredbytheProvisionsoftheASMECode.SectionIII.Division1Pg.of1.ManufacturedandcenrfiedbyHENRYPRATTCOMPANYTV2.Manutacturedfor3.LocauonofinstallationInameandaddressotNCanrhcateHolder)FLORIDAPOWERANDLIGHT(nameandaddressotParcnaserorownenST.LUCIEUNIT2(nameandaddress)4.ModelNo..SeriesNo.~orType5.ASMECode.SectionIll,Division1:1974DrawingN/ARev.N/ASUM743CRNN/AN/A6.PumporvalveVALVE7Matr,-ai.Br)dSA516GR70(edmon)Nomina(inletsizeBonnetIaddendadaterIdassi100detsize(in.)lin.IDiskSA351CFSMBolting(CodeCaseno.)SAlGR8(alCen.Holder'sSerialNo.(blNat'IBoardNo.NA(clBodySerialNo,802H41790802H41790(dlSonnetSerialNo.N/AN/A(elOis((SerialNo.T180-T18-4'Supplementalintonnationinformofrists.sketches,ordrswinesmavbeusedprovided(1)sizeis8)(x11.121InformationinitemsIthrough4onthisoatsReponisindudedoneachsheet,(3)eachsheetisnumberedandthenumberofsheetsisrecordedstthetopofthisform.()2JB())Thisform(E00037)maybeobtainedfromtheOrderOept.,ASME,22Laworivesos2300.Faireeld.NJ07007.2300.
: 9. Remarks            FINAL INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
lR~~Ipage~etFORMNPV-1(kcckl20F20074B.Remarks9.Designconditions(pressurel110.Coldworkingpressure285psi200ttemoereturerpsiat1004F4Forvalvepressureclass11.Hydrostatictest450psi.Diskdifferentialtestpressure165psiCERTIFICATIONOFDESIGNDesignSpectficationcerufiedbyDesignReportcertifiedbyKEITHLB%PEStateP.E.StateFLR13797.gPCERTIFICATEOFSHOPCOMPLIANCEWecertifythatthestatementsmadeinthisreponarecorrectandthatthispumporvalveconformstotherulesforconstructionoftheASMECode,Sectionlli,Division1.N1030NCertificateofAuthorizationNo.ExpiresDate~"I<'7~ameSigned(NCert>fkesteHolderteseotsuvet(eutnonteCERTIFICATEOFSHOPINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvinceofandemployedbyofhaveinspectedthepump,orvalve,descnbedinthisOatsReporton-I,19~~.andstatethattothebestofmyknowledgeandbelief,theCerttflcateHolderhasconstructedthispump.orvalve.inaccordancewiththeASMECode,SectionIII,Division1.Bysigningthiscertificate.'eithortheinspectornorhisemployermakesanywarranty,expressedorimplied.concerningthecomponentdescribedinthisDataReport.Furthermore,neithertheinspoctornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnectedwiththisinspection.Date'+Signed~3'-r~.,wCommissions'>5Xf-IoptedIpector>(Net'I.Bd.lied.endorsernents)stateorprov.sndno.lI1)Formanuallyoperatedvalvesonly.
: 10. Inspection Report Numbers:             MM96-161 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate      of  Compliance We certify that the statements made in the report are correct and this            [X ] Repair        [ ] Replacement conforms to the rules of the Asme Code, Section XI.
PSL-1,NIS-2TRACKINGNO.SL-2-8-53FPLFORMNIS-2OWIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/07/95Sheet:Iof2Unit:2P.o.f/:C92933-90719PCMf/:N/ANPWOff:8234WO//:95028735-01WCD//:'N/A4.(a)IdentificationofSystemCCWSUPPLYHEADER(b)ComponentIdentificationVALVESB14530(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1974S1974ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)VALVE-10"HENRYPRATICO.D44725-8-1N/ASA516GR.70N/AREPLACEDYESVALVE-10"HENRYPRATTCO.0D74-1-2N/AUTC383729SA516GR.70RIR3H-0911B1993REPLACEMENTYES7.DESCRIPTIONOFWORK:PLANTWASUNABLETOTIE-INPERPCM058-295(PERM.CONT.A/C)VALVEWASLEAKINGATTHESEATATARATEOF2GAL.PERMINUTE.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]VT3[]NominalOperatingPressure(ISLT)[X]sYSTEMPSIGTestTemp.SYSTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-FORINNIS-2(Back)Sheet2of9.RemarksISLTFORTHEFLANGEDCONNECTIONSONVALVESB-14530WASSATISFACTORILYPERFORMED.10.InspectionReportNumbers:M95-466APPLICABLEMANUFACTURER'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwner'slge,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate19~>
Type CodeSymbol Stamp:                 N/A Certificate  of Authorization    No    N/A Signed Owners or Ow    I's DB  Ree, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors  and  the State  or Providence  of Florida  and employed by  Arkwright  Mutual Insurance Company have inspected the components described in this        Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
)Rg]4-oqf(Page<ot~(FORMNPV-1CERTIFICATEHOLDERS'ATAREPORT%RPUMPSORVALVESAsRequiredbytheProvisionsoftheASMECode,SectionIII,Division1Pg.1of1.ManufacturedandcertifiedbyHENRYPRATTC(NPANY00TAtnameandaddressotNcernricateHoideri2.ManufacturedforLOIDAPO~RANDLIGHT(nameandaddressotParcnaserorowneri3.l.ocahonofinstallationST>>LUCIE4.ModelNo..SeriesNo..orTypeUNIT2(nameandaddiessiOrawingN/ARevN/AC((NN/A5.ASMECode,SectionIII,Oivision1:6.PumporvalveVALVE7MtnalBod1974(editionlNominalinletsizeBonnettaddendacater10tr(in.lIcrassrtnitOutletsizelin.ISUM743N/A(CodeCaseno.i(alCen.Holder'sSerialNo.(b)Nat'IBoardNo.NANA(c)BodySerialNo.802H41790802H41790(d)BonnetSerialNo.N/AN/A(elOiskSerialNo.T18T18-4'supplementalinformationintermotasts.sketches,ordrawingsmaybeusedprovided(1)sizeis8))x11.(21informationinitems1through4onthisoatsReportisindud<<doneachsheet,l3)eachsheetisnumberedandthenumberolsheetsisrecordedatthetopofthisform.112/88)th(sform(E00037)maybeobtainedfromtheorderoept..ASME,22tawDrive.8ox2300.Faireield.N307007-2300.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
la~-~~~~psife~ofFORMNPV-1(back)20F2DD7".8.Remarks9.Oestgnconditionsipressure>10.Coldworkingpressure285psj200itempcrsturerpsiat1004FeForvalvepressureclass11.Hydrostatictestpsi.Oiskdifferentialtestpressure165pslCERTIFICATIONOFOESIGNOesignSpecificationcertifiedbyOesignReportcartigredbyKEITHLP.E.StateP.E.StateReg.no.RI<o.~~M'poqPCERTIFICATEOFSHOPCOMPLIANCEWecertifythatthestatementsmadeinthisreportarecorrectandthatthispumporvalveconformstotherulesforconstructionoftheASMECode.SectionIII.Division1.N1030NCertificateofAuthorizationNo.ExpiresOste~"~~~~arneSignedINCenrricsteHolder>leutnonzeesentstrverCERTIFICATEOFSHOPINSPECTIONI~theundersigned.holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandntheStateorProvinceofandemployedbyothaveinspectedthepump,orvalve.descnbedinthisOatsReporton-/,19~~.andstatethattothebestofmyknowledgeandbelief.theCertificateHolderhasconstructedthispump,orvalve,inaccordancewiththeASMECode,SectionIII.Oivision1.Bysigningthiscertificate.neithertheinspectornorhisemployermakesanywarranty,expressedorimplied.concerningthecomponentdescribedinthisOatsReport.Furthermore,neithertheinspectornorhisemployershallbeliableinanymannerforanypersonalInjuryorpropertydamageoralossofanykindarisingfromorconnectedwiththisinspection.Oats'+Signed2-rg..Commissions')KZLfnzedIpeerpnINet'I.Bd.(ind.endorsementsistateorprov.sndno.ll1)Formanuallyoperatedvalvesonly.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
,PSL-1,NIS-2TRACKINGNO.SL-2-8-054F~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJcnscnBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V071204.(a)IdentificationofSystem:ContainmentSprayDate:11/2/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:8801WO&#xb9;:94007594CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEcnoNIII1986EomoNNoAoosNoACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandRcplacemcntComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentiTicationYearBuiltReplacedRepairedorReplacementASMECodeStampedYorFlangeStud11/4'8uncFlangeStud11/4'8uncBFShawAlliedNut&BoltNFHeatNo90755/TRN27NASA193GrB7SA193GrB7NAReplacedNAReplacementN)NN7.DescriptionofWork:Replacedflangestudduetodamage.8.TestsConducted:Hydrostatic~Pneumatic'ominalOperatingPressure(ISLT)XOther.VT1VT2XVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2N-054FORMNIS-2(Back)'heet2of29.Remarks:AsatisfactoryInserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-1524APPUCABLEMAMUFAOTURESOATAREPORTSToBEATfACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedl4.SLWpvOwnerortsDesignee,TitleDateIt~19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate
Commissions Inspectors Signature                                National Board, State, Providence and Endorsements Date


PSL-1,NIS-2TRACKINGNO.SL-2-8-55FORMYiIS-2OIVtAVERSREPORTFORREPAIRSORREPLACEIilENTSJAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:11/17/95Sheet:Iof2Unit:2P.O.//:88929-92668PCMI/:N/ANPWO//:8210WO0:95012782-02WCDf/:01974.(a)IdentificationofSystemINTAKECOOLINGWATER(b)ComponentIdentificationVALVEV-21162(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1977S1977ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofManufacturerComponentorManufacturerSerialorHeatMaterialNo.NationalBoardNo.OtherYearReplacedIdentificationBuiltRepairedorReplacementASMECodeStamped(YorN)VALVE-30"TRWMISSIONVALVECO.TAGI-V-21678FIG.15-SNF-921SA216GR.WCBN/AREPLACEDVALVE-30"C&SVALVECOMPANY89G213801-Z0663UTC349242SA216GR.WCBRIR3J-13751995REPLACEMENTYES7.DESCRIPTIONOFWORK:DURINGINSPECTION,M/MSUPV.DETERMINEDTHATTHEVALVENEEDEDTOBEREPLACED.8.TestConducted:Hydrostatic[]Other.VT1[]VT2[X]Pneumatic[]VT3[]NominalOperatingPressure(ISLT)[X]SYSTEMPSIGTestTemp.SYSTEMFHoldTime4HQURs
PSL-1, NIS-2 TRACKING NO. S L 8 -               98 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section    XI
: 1. Owner                                Florida Power  & Light Co.                     Date: 12/11/95 P. O. Box 529100                              Sheet:    1          of  2 Miami, FL 33152                                Unit: 2
: 2. Plant                                St. Lucie Nuclear Plant                        P.O. f/: N/A 6501 South Hwy. A1A                          PCM f/: 190-295 Jensen Beach,  FL 34957                    NPWO f/: 9105
: 3. Work Performed By:                   Florida Power  & Light Co.                    WO ff: 95033072-01 6501 South Hwy. A I A                          WCD f/0271 Jensen Beach,  FL 34957
: 4. (a) Identification of System        BOILER FEEDWATER                            Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification        SUPPORT BF-4007-7008                                    Expiration Date N/A (Mark Number)
(c) Code Class:    N/A (SUPPORT)
: 5. (a) Applicable Construction Code and Addenda:           ASME 1974 S 1974 ADD. Code Case:                     N/A (b) Applicable  Edition of Section XI  for Repairs and  Replacement Components: 1989 Edition
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of          Name of      Manufacturer        National      Other      Year Replaced            ASME Code Component or        Manufacturer Serial or Heat          Board    Identification Built Repaired or          Stamped Material                              No.           No.                               Replacement      (Y or N)
CAP SCREW                                                            A325 3/4"-10UNC2A X 2      ALLIEDNUT                                      UTC 378011 1/2"         AND BOLT CO.         B02156          N/A      RIR 3AD4723      1991  REPLACEMENT          NO A194 GR. 2H NUT, HEAVY HEX        ALLIEDNUT                                      UTC 377944 3/4"-10UNC 2B      AND BOLT CO.         B47139          N/A      RIR 3AH-2141    1993    REPLACEMENT
: 7. DESCRIPTION OF WORK:                 GAPPING, LOOSE BOLTING AND SIGNS OF RUBBING WERE IDENTIFIED DURING AN ENGINEERING WALKDOWN. PCM 190-295 WAS GENERATED TO REPLACE THE BOLTING WITH A LARGER DIAMETER, HIGHER STRENGTH BOLTING .
: 8. Test Conducted:           Hydrostatic [ ]                 Pneumatic  []                 Nominal Operating Pressure (ISLT) []
VT2[]             VT3 [X]                                 Test Temp.                oF Other: VT1    []                                                       PSIG Hold Time


PSL-1,NIS-2TRACKINGNO.SL-2-8-55FORMNIS-2(Back)Sheet2of9.RemarksISLTFORTHEFLANGEDCONNECTIONSONVALVEV-21162WASSATISFACTORILYPERFORMED.10.InspectionReportNumbers:M95-301APPUCAIREMANUFACTURER'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[XJReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwneDesnee,TrUeDate>~l11CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescnbedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmykrewledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.IBysigningthiscertificateneithertheinspectornorhisemployermakesanywarranty,expressedorimplied,concemlngtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate FORMNPV-1CERTlRCATEHOLDERS'ATAREPORTFORNUCLEARPUMPSORVALVESeAeRequiredbytheProvleloneoftheASMECode,sectionill.Division1Pg.1ofModelNoSerieaNoorZypeDualPlate*,,.GLSYalveCo.,MzlearProductsDiv.;40~i~tAve.;Westmont,lL6K1.Manufacturedandcert(f(edby(nsn(ssndsddtsssofNCsn(nestsHc(dsr(Flori~~g,Li~QzPai1y;P.Q.KN12S;FortPierce.Florida34954(nsmssndaddressofpurchaser}.3Locationofinstallation1Ori+~~LightCat+~ie~6501RUUlA1A;~Heach,Florid(hsmesndsddfsss(g(,;~94-2PM1NRAggN/A5.ASMBCode.SectionIII,Oh(alon1~Ennea1%43N-133-1d.pumpervahe(ed(t(onlNominalinletaix7.Material:BodyBonnet(CodsCaseno.)(addendacats)(c(ass(X"Outletaixe(In.l(in.lol,m148e.m~,See~Side(Plateia)Cert.Holder'sSerialNo.ib)Nat'IBoardNo.ic)BodySer(alNo.id)BonnetSer(alNo.ie)Oia)(SerialNo.'voo(smenta(informationinformofasts,snatches.ordrawingsmayheusedprovidedl1)s(teis1%x11,l2)infonnaooninitems1throughionth(>>ostaftsoortlainc(udedonsechsheet.(2)sechsheetisnumberedsndthenumosrofsheetsisrscordeoatthetooofth(sform.(12/88)TNsream(axe37)maybeo~fmtheorderoeot..idML22ta0~.do*2200.Faeee.M0700T2200*8(xtymanufacturedbyCSSYalvemhrM089-05K?41(N)-01.PlatesmanufacturedbyQSYalveas~~~~F89-0606(Nl.~i~libbyFl~eF)aLi~.g'g-z-p-05+
PSL-1, NIS-2 TRACKING NO. S L 8 -               98 FORM NIS-2           (Back)                 Sheet    2  of
gZJ-IVVS-P~tcsFORMNPV-1tBack-Pg.2of)CertificateHolder'sSenalffo.862<1(N)<1$.Designconditionsipreaeurel9.Coldworkingpressure10.Hydrostatictestpsj100iternpereturelpsi.DiskdifferentialteatpressureeForvsl~pressureclass11pal11.Remarks:DesignSpecificadoncertifiedbyDesignReportcartifiedbyCHlTIFICATIONOFOKSIQNP.E.State~~+P.E.StateR~~.~>RaganowCEllTIFICATIOFCOMPUANCIWecertifthatthestatementsmadeinthisreportar~correctandthatthispumporvalveconformstotherulesforconstructionoftheASM'ode,SectionIII,DivisionI.NCertificateofAuthorlxadonNo.6/20/95,C5SValyeCO.Re.~~DiV.SI~WCeroficeteHolderlIwtnorieedrepresentsdvelCSmFICATIOFIN4$%CTlONI.theundersigned.holdingavalidcommissionissuedbytheNationalBoardofBogerandPressureVesselInorsand*theStateorProvinceofandemployedbyofhaveinspectedthepump,orvalve.describedinthisDataReporton~andstatethattothebestotmyknowledgeandbegeftheCertificateHolderhasconstructedthfapump.orvalve.inaccordancewiththeASMECode,Secdonill,Division1.+FtbtualineeriwAssociatianBysigningthfacertitlcat>>.neithertheinspectornorhlaemployerany,axpreaorimplied.concerningthecomponentdeacrfbedlnthisOat>>Report.Furthermore,neithertheinspectornorhfaemployershawbeliableinanymannerforanypersonalInjuryorpropertydamageoralossofanykindarisingfromorconnectedwiththfainapecdon.O~+SignedchalFrpI'norlIffet'I.ad.finer.endoreeroentsiendststeorprov.endno.ll1)Formanuallyoperatedvalvesonly.  
: 9. Remarks            FINAL INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
(>>I,k((ILIlarV.II(~II>>v<<>>I~AaRoe)r(redby.t)toBoo{alonecftheASN%~.Sect)onN,()br.1~5'>>'l'~I'4'I;1(,)4AAltauredby0:ltanuaecturedlorLLocedond(~~~g'-'i4,Aae0orViho~~~(a)Mode{NoNo'orType'((b))tCert(AcateHOMar's""'.:.0er{al.;-Ho,.>>".Inch)Reglatret(on~'d)Drawing',".*~.~,",(()Nat'I.No.".".No.-{e)CIaae.ed.No.~(0)Year~;e~h1%g-7'!OfVfsiCn'.40CheartAVe.'MSStmat,IL6Q559-11%Shach'laridi"BI%8-1morfvweeew{a)~{10)>>'~rOlsfeaacneoonorSanacafer~~L~4~IFtsA1'~ogpg+gaiColdWore)nyProcure-.'palet10M'.':Pressure{tete(ningtleeee1'porValveheaaure~(4A~,.'.'>>,~'%'."."':;-')'-~~IIMater{a(Spec.No."Nawfacturer;(e)~IS-.~~{b)Forylnye~~>>t~~''l)totmeweiyoperatedvalseon)y.:,':,i."'Nupplementalaheetalnterriol)lathebeacieeordraw(neomeybeusedyeekSe)(1)a{acle4'lO'11;N)(rv)orrnetlonln~)tome10and5ond(eocta((aportleinctudedoneachsheet,and0)eachsheetlenumberedandnumberoteheetaleretordedattetroithisform.~~~~~."..{14Nl*:':,..''llewierrrt{SCPjhwraeeitaawdrjorntheO'erOaotANt,0'CO0tNewVeA,NY.10011~~'IIrr~'.~,rr>>>>eLy~I~+Pl~>>rqual>>'(r~qayq.i~>>r'->~
: 10. Inspection Report Numbers:           M95450 APPUCABLE MANUFACTURERS DATA REPORTS To BE ATTACHED Certificate    of    Compliance We certify that the statements made in the report are correct and this [ ] Repair                 [ X] Replacement conforms to the rules of the Asme Code, Section XI.
Type CodeSymbol Stamp:               N/A Certificate of Authorization No N/A Owners or Owne    Desi  Be, Title Date      I~I  [~,        19  ~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectors Signature                              National Board, State, Providence and Endorsements Date                                                    19  /d


Yc'iV,tqi'aQe)Je,~IeaaatlelQyec.HO.~r+,r'4~~~.(,~',I~'4~'Q.4.~'V4IILLIILIL44r'LI..ILILNIIIILIIILmeyLLLLLI.-~n~21Q.CStfHCAT%Of~ANCEWecenlfyaacd>>aaceenoncemadelnthlateponatecotteccendtt>>cthlepump,ot.valve.confom>>aOetulaeaf-IIII-"-Addenda.-LI3hl-'SYam,TricentrlcDivisicn.NCNINcaltNQQatttOutANNCad&ereofAuthokcedonNo.ioueeOe6/8l/%~IIII'4PIIILoe.q~~...'...,,CSRTPCNNN'INON~;,'~,DeelOninfonnedononleec'"*Sbeeeanelyeletepott(Oeee1onlylonOeecDeeiyaepecl5cedone~ledby(flScteeecenNedbyil),')1spneleenotteeuited.Licenanoeely.',V-~'I-.v.'<<1.;,'2;,'-4'IgfPICA75Of~Ngf!CT)OHIOeundeteiined;hoNnIeveNdcommlealonieeuedbyoeNatonalIoetdoflollerendAeee22teWeealb~dore~ndOeeceeeorftevincoef'ndemployedby*ofhoveInepeccedOepump.orvere,deecHbodlnOleDekehapotcm)0~,endeasooecloeebeeotmyIQnewledoeendbeNet.oeNcenMlceaHoldaheeconeauceedOlepump,erveiv>>.lnaccordancevQOhOeASMICode.SecdonN.~yeiininyNece&HceiIInQheroeInepeceornotNeemployermeheeeny>>ettencyeaptc>>eedethapa4eencendni0NequiptnenIdeecrlbedlnNeDacehepotc.twthonnote.neioetOeInepeccotnorNeetnployereNIbeIelleInenymav>>rIer~orptope&darnedotelocaofeny~etielneAotnotconnecleiah%ole@operon.ss-c'onwnleeione~I>>an(tracedeesea,~aaeNalgL~
PSL-S, NIS-2 TRACKING NO.               SL-2-S-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
PSL-1,NIS-2TRACKINGNO.SL-2-8-56FPLFORMNIS-2OiVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/27/95Sheet:1of2Unit:2P.O.&#xb9;:C95934-90011PCM&#xb9;:N/ANPWO&#xb9;:8218WO&#xb9;:95012801-03WCD&#xb9;:01894.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)INTAKECOOLINGWATERVALVEV-21189TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:5.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialVALVE-4"SA516GR.70VALVE-4"SA516GR.70NUT,HH-SA1945/8"-11UNC2BBOLTNA1935/8"-11UNC2ANameofManufacturerHENRYPRATTHENRYPRATTALLIED,NUTANDBOLTALLIED,NUTANDBOLTManufacturerSerialorHeatNo.SERIAL&#xb9;D0066-3-2SERIAL&#xb9;DD343-1-2HEAT&#xb9;L63812HEAT&#xb9;88147-GPNationalBoardNo.N/AN/AN/AN/AOtherIdentificationN/AUTC377172RIR26612UTC375497RIR25731UTC372557RIR1J-0247YearReplacedBuiltRepairedorReplacement1977REPLACED1995REPLACEMENT1995REPLACEMENT1994REPLACEMENTASMECodeStamped(YorN)NONO7.DESCRIPTIONOFWORK:DURINGINSPECTION,M/MSUPV.DETERMINEDTHATTHEVALVENEEDEDTOBEREPLACED.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumaticf]VT3[]NominalOperatingPressure(ISLT)[X]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HQURs
: l. Owner:                        Florida Power & Light Co.               Date:      12/2/95 P.O. Box 529100                          Sheet:      1 of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:              Florida Power & Light Co.                PWO&#xb9;: 4413 6501 South Hwy. A1A WO &#xb9;:       9501703 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:      N/A
: 4. (a) Identification    of System:    Chemical 8 Volume Control Type Code Symbol Stamp          N/A V2555 Authorization No.              N/A (b) Component Identification:                                                                      Expiration Date                N/A (Mark Number)
(c) Code Class:     2 (a) Applicable Construction Code and Addenda:           ASME SEC. III,1977 ED., 77 ADDEN.           Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National        Other          Year      Replaced            ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired            Code or                                      No.         No. Identification                                  Stamped ol'eplacement Material (Y or N) eat o                                                ep acement HT 306778
: 7. Description of Work:     REPLACE PLUG/STEM ASSEMBLY DUE TO SEAT LEAKAGE.
: 8. Tests Conducted:         Hydrostatic               Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1           VT 2          VT 3      .              psig    Test Temp.                   'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-'6FORNINIS-2(Back)Sheet2of9.RemarksISLTFORTHEFLANGEDCONNECTIONSONVALVEV-21189WASSATISFACTORILYPERFORMED.10.InspectionReportNumbers:M95-313APPLICABLEMANUFACTURER'sDATAREPDRTBToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationN/ASignedOwnsorOwnei'sDesignee,TitleDate/~7,19CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceoffloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate~2719~a PSL-I,NIS-2TRACKINGNO.SL-2-2-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1PORVV14753WorkPerformedBy'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ReactorCoolantDate:12/1/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3609WO&#xb9;:95001904CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1977Ed/S79AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialonneionneiNameofManufacturerarrettrosyaeManufacturerSerialorHeatNo.enaoK7204-324002NationalBoardNo.OtherIdentificationGrF316GrF316YearBuilt94ReplacedRepairedorReplacementepaceepacementASMECodeStampedPorN)7.DescriptionofWork:Replacebonnetduetoloosebonnetguide.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.IF PSL-2,NIS-2TRACKINGNO.SL-2-8-FORIINIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthozationNo.:N/ASignednerrneCsDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.lnspectoCsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsements
PSL-2, NIS-2TRACKING NO.                   SL-2       099 FORM NIS-2 (Back)                                         Sheet 2 of 2
~>>'>>~'r,>>>>S'I.'>>>>'>>>>>>'.I>>>>>>>>>>>>'>>'.I",>>;c''~>>',.*IliCL(Lre&~II~''>>J~>>~~~>>~,~~~$0~1'>>~>>~II~:I~>>I~>>~~~~'~IIIIIIII~~>>~~~~~~~~~'~~'~~~I~~>>~~~~~~~~~1~~~>>~~>>i~~~~I~'~~1~~,~~>>~i~~~~~~~~~~a~>>~~~>>~~~>>~~~\~~~>>~~>>~~~~1~~>>~~~~>>~>>~'~~~~~I
: 9. Remarks:          A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
~~~lPI~'~~IIW'j,ia~I~~~I~~I~~~I'~'c>i~jjsifr.''~~'~~~'/gIII~~I~'II~~'~I~~I~L~~'~~~~~~~~~~II~'~~~~~I~~III~~~'~'~~~I~~~~I~~~~~~~~I'~I~~~'I~,~9~-":iW7"~5fipM9~vRQXLa~JK8Ka.".F&~~~d,'W~~4~W"ljJgJ"i,"\1~'~~~I~~~~I'I,gl~'~~Lt''[~g'I~~I~~~~~ILIII~jL/~gg~~~IyI~'~'I'~I~I~~I~~'~I~~i'III~~~~~~~~,'~~~~1'II'~~'~.I;~I1~.?~I'8I~~~~~I''~~~.J~.ggs"gL:,',
: 10. Inspection Report Numbers:         6AM CI 6    - R O'C'~
PSL-1,NIS-2TRACKINGNO.SL-2-8-~058FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2HCV-36353.WorkPerformedBy.FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/14/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4972WO&#xb9;:95027851CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)SealWeld(SI-2000)NAHtNoDT6289NAP8ToP8ER316NAReplacement7.DescriptionofWork:'Removesealweldforvalveinspectionandreweldfollowingexamination.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~prigTeetTemp.~'P
APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair   X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed              (                                                   Date~ I,19                    )S er o  wnei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719      FL  Com&#xb9;60 Inspector's Signature                                      National Board, State, Providence and Endorsements Date


PSL-2,NIS-2TRACKINGNO.SL-2-8-OSSFORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedWPI.UI/-lSlOwnrrOwner'sDesignee,TitleDate~&IIi19~7CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwneVSReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.M.k~InspectorsSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-59FORMNIS-2OiVFAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.PlantFloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957Date:12/18/95Sheet:IUnit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8210of23.WorkPerformedBy:4.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957INTAKECOOLINGEXPANSIONJOINTSJ-21-4AWO&#xb9;:95012782-01WCD&#xb9;:0195TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofManufacturerComponentorManufacturerSerialorHeatMaterialNo.NationalBoardNo.OtherYearReplacedASMECodeIdentificationBuiltRepairedorStampedReplacement(YorN)24"EXPANSIONJOINTSA182F316ABB/CE24"EXPANSIONPATHWAYJOINTSA182F316BELLOWSHT&#xb9;AMNTPT&#xb9;B-14392HT&#xb9;610VNEPT&#xb9;B-1-7832UTC384322RIR3H-3361N/AREPLACED1993ReplacementNONOBOLT,SA193GR.B711/4"-8UN2AALLIEDNUTANDBOLTCO.HEAT&#xb9;90755NIAUTC379706RIR2H-16801993ReplacementNONUT,HEAVYHEXSA194GR.2HALLIEDNUTHEAT&#xb9;11/44UN2BANDBOLTCO.E97817/151593N/ARIR21-1002RIR247421994/1995ReplacementNO7.DESCRIPTIONOFWORK:EXPANSIONJOINTWASREPIACEDBECAUSEOFPITTINGANDCORROSION.BOLTING,BECAUSEOFNORMALWEARAND.TEAR.8.TestConducted:Hydrostatic[]Other.VT1[]VT2[X]Pneumatic[]NominalOperatingPressure(ISLT)[X]VT3[]sYsTEMPSIGTestTemp.BYBTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-59FORMNIS-2(Back)Sheet2of9.RemarksANISLTWASSUCCESSFULLYPERFORMEDONTHEFLANGEDCONNECTIONSANDWITNESSEDBYACERTIFIEDQ.C.INSPECTOR10.InspectionReportNumbers:M95-302APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair(X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorneesignee,TitleDateDt'-1'-~19~$CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.8dInspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate
PSL-2, NIS-2 TRACKING NO.               SL-2     ~100 g          FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F                        As Required by thc Provisions of thc ASME Code Section XI
: l. Owner:                       Florida Power & Light Co.               Date:       12/8/95 P.O. Box 529100                          Sheet:      1 of Miami FL 33152 Unit:      2
: 2. Plant:                        St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:     N/A Jensen Beach, FL 34957                  PCM&#xb9;: N/A
: 3. Work Performed By:          Florida Power & Light Co.                PWO    &#xb9;: 3624 6501 South Hwy. A1A WO &#xb9;:       94025081 Jensen Beach, FL 34957 CWO    &#xb9;: N/A          Process Sheet:  N/A
: 4. (a) Identification of System:      Safety Injection Type Code Symbol Stamp    N/A V3211 Authorization No.        N/A (b) Component Identification:                                                                    Expiration Date          N/A (Mark Number)
(c) Code  Class:   2 a) Applicable Construction Code and Addenda:           ASME SEC. III; 1974 EDITION              Code Case: None (b) Applicable Edition of Section  XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components Repaired or Replaced and Replacement Components:
Type of            Name of        Manufacturer    National        Other          Year      Replaced      ASME Component          Manufacturer      Serial or Heat  Board                        Built    Repaired      Code or                                    No.         No. Identification                    or        Stamped Material                                                                                    Replacement (Yor N) 3/4" - 10 UNC 2A ALL        ALLIED            HEAT &#xb9;;       NA      SA 193; GRADE                Replacement      N THREAD                                88147-GP                      87 3/4-10 UNC 28          ALLIED            HEAT &#xb9;:        NA      SA 194, GRADE                Replacement NUTS                                  604277                        2H
: 7. Description of Work:    REPLACE INLET FLANGE BOLTS (2 EA.) DAMAGED DURING REMOVALOF VALVE.
: 8. Tests Conducted:     Hydrostatic             Pneumatic               Nominal Operating Pressure (ISLT)     X Other: VT1            VT2 X       VT3              ~psig          TestTemp.             'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OiVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:,,FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35503.WorkPerformedBy.FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/21/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4518WO&#xb9;:95018944CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEGTIII1974EomowSuM75AooCodeCase:None(b)ApplicableEditionofSectionXlUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialbiseemAssemblyiscternAssemblyNameofManufacturerargeoargetoManufacturerSerialorHeatNo.00000352219NationalBoardNo.OtherIdentificationTP347TP347YearBuiltReplacedRepairedolReplacementcpaccepaccmentASMECodeStamped(YorN)7.DescriptionofWork:Replacedisc/stemassemblyNote:SealweldreplacedRefWO95030191/NIS-2SL-2-8-0608.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.
PSL-2, NIS-2 TRACKING NO.                 SL-2         100 FORM NIS-2 (Back)                                        Sheet 2 of 2
: 9. Remarks:       A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:         N i~ ( 6 0 [35 APPUCABLE MANUFACTURES OATA REPORTS To SE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair    X  Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed  Y4 4 vmer SR P Ovmer's Designee, Title Date~                  19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL Com          &#xb9;60 Ins ectoi's signature                                      National Board, State, Providence and Endorsements Date                              , 19 9.(


PSL-2,NIS-2TRACKINGNO.SL-24-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector10.InspectionReportNumbers:1VlI419g-ZGDfAPPLICABLEMANOFACTURESOATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned4&Zp)t.ftlvigv~hSLnsronei'sDesignee,TitleDateititttteID-19WCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Insp'tor'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-061igFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V35503.WorkPerformedBy'FloridaPower&LightCo.6501SouthHivy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/24/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5226WO&#xb9;:95030191CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESECTIONIII;1980EDITIONCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialSEALWELDFW-2003NameofManufacturerFPLManufacturerSerialorHeatNo.WELDTRAV&#xb9;954375NationalBoardNo.NAOtherIdentificationYearBuiltReplacedRepairedofReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWorkSEALWELD8FILLETWELD8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~pstgTestTemp.~'F PSL-2,NtS-2TRACKtNGNO.SL-2-8-~061FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector10.InspectionReportNumbers:QCR:2009APPUCABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedCu,9Zerorei'sDesignee,TitleDatettAe<2'I1995'ERTIFICATEOFINSERVICEINSPECTIONe,I,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;6startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsemantsDate19JCC
PSL-1, NIS-2 TRACKING NO.               SL-2                                               FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP                          As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                         Florida Power & Light Co.                 Date:     12/6/95 P.O. Box 529100                          Sheet:      I of    3 Miami, FL 33152 Unit:
: 2. Plant:                            St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:                Florida Power & Light Co.                PWO&#xb9;: 4287 6501 South Hwy. A I A WO&#xb9;:       95016029 1A Jensen Beach, FL 34957                                95016029 01 CWO    &#xb9;: NA          Process Sheet: N/A
: 4. (a) Identification    of System:      Main Steam Type Code Symbol Stamp      N/A Authorization No.         N/A (b) Component                        V8201 ( S/N 59335-00-0001)
V8207 ( S/N 59335-00-0007)                        Expiration Date          N/A Identification:
(Mark Number)            V8208 ( S/N 59335-00-0008)
(c) Code Class:       2            V8211 ( S/N 59335-00-0011)
V8213 ( S/N 59335-00-0013)
ASME Sect lil 1974 Ed / No Add          Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components Type of              Name of          Manufacturer      National      Other          Year      Replaced      ASME Component          Manufacturer        Serial or Heat    Board                        Built      Repaired      Code or                                        No.         No. Identification                    or        Stamped Material                                                                                        Replacement (Y or N)
Isc nsert            rosy    a e          ena    o                          4                    ep ace (V8211)                               N 91608-334026                  Gr651 isc nsert            rosy    a e          aena aa                          458      99        ep acement (V8211)                                N91 608-344027                  Gr651
        >sc  nsert          ros y    ave          ena    o        NA          $ TA4S8                    ep ace (V8201)                                N 91608-31-0014                  Gr651 isc nsert            ros y    ave          ena    o                            8       992      ep acement (V8201)                              N91608-34-0030                    Gr651 pm e    ssy          ros y ave              ena    o                            93                  ep ace (V8201)                                K5720 84841 26                  Gr 86 pin e    ssy          ros y  ave          ena    o                            93    1995      ep acement (V8201)                               K57208<94119                    Gr 86
: 7. Description of Work:         Replaced disc inserts and spindle assemblies on listed valves.
: 8. Tests Conducted:           Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1              VT2~        VT3                      psig    Test Temp.             'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V34956501SouthHwy.AIAJensenBeach,FL349573WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/20/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5229WO&#xb9;:95030271CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedand.ReplacementComponents:TypeofComponentorMaterialeae95-'33+%NameofManufacturerManufacturerSerialorHeatNo.eaoDT6289NationalBoardNo.OtherIdentification(P8toP8)YearBuiltReplacedRepairedofReplacementepacemenASMECodeStamped(YorN)7.DescriptionofWork:Removeandreplacesealweldtofacilitatevalvework.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other.VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:MM95-1892APPLICABLEMANUFACTURE'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedspf4snsUpa2ulsa2.-~<~Daleu~.0>19~DOwneoOwner'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDatej-(-,19~~"
0 PSL-2, NIS-2 TRACKING NO.               SL-2                                                   FORM NIS-2 (Back)                                       Sheet 2 of      3
PSL-2,NIS-2TRACKINGNO.SL-2-8-63FORMNIS-2OiVNERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.OwnerFloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:01/18/96Sheet:3Unit:2of3P.O.&#xb9;:N/APCM&#xb9;:N/A2.PlantSt.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.,6501SA1AHwy.,JensenBch.,FL349574.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMFCodeStamped(YorN)ELBOW,4"90DEG.,SA234ELBOW,4"90DEG.,SA234ELBOW,4"45DEG.~SA234ELBOW,4"45DEG.~SA234BOLT-SA1935/8"-11UNC2ABOLT-SA1935/8"-11UNC2ANUT-SA1945/8"-11UNC2BBOLT-SA19311/4"-8UNC2ANUT-SA19411/4"-8UN2BNIADUBOSENATLENERGYN/ADUBOSENA'PLENERGYALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTALLIEDNUTANDBOLTNIAHEAT&#xb9;N87038N/AHEAT&#xb9;N75134HEAT&#xb9;88147-GPHEAT&#xb9;8078593HEAT&#xb9;L63812HEAT&#xb9;8894177HEAT&#xb9;151593N/AN/AN/AN/AN/ANIAN/AN/AN/AUTC381319RIR30129NIAUTC381320RIR30129UTC347675RIR1J-1421UTC374492RIR24742UTC375497RIR25731UTC373936RIR24401UTC374489RIR24742N/AReplaced1995ReplacementN/AReplaced199sReplacement1994Replacement1995Replacement199sReplacement199sReplacement1995ReplacementNONONONONONONO PSL-1,NIS-2TRACKINGNO.SL-2-8-63FORMNIS-2OIVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:01/18/96Sheet:Iof3Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8218WO&#xb9;:95012801-01WCD&#xb9;:01874.(a)IdentificationofSystem(b)ComponentIdentification(MarkNumber)(c)CodeClass:3INTAKECOOLINGWATERLINEI-364iV-16LINEI-30-CiV-2lTypeCodeSymbolStampN/AExpirationDateN/A5.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989Edition6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:N/ATypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)FLANGE,SA1054",WELDNECKN/AN/ANIAN/ANIAReplacedNOFLANGE,SA1054",WELDNECKFLANGE,SA1054",SLIPONFLANGE,SA1054",SLIPONPIPE,4"SA106TIOGAPIPESUPPLYCO.N/ATIOGAPIPESUPPLYCO.TIOGAPIPESUPPLYCO.HEAT&#xb9;8860283N/AHEAT&#xb9;8861721HEAT&#xb9;N87139NIANIANIAN/AUTC374412RIR249171995N/ANIAUTC378524RIR278181995UTC382058RIR2K-00321994REPLACEMENTReplacedREPLACEMENTREPLACEMENTNONONONO7.DESCRIPTIONOFWORK:PUP"PIECEADDEDTOEASEFITUPOFFLANGE.BOLTINGANDFLANGES,WHICHWEREWORN,DUETONORMALWEARANDTEARWEREREPLACEDPERFPLDIRECTION.8.TestConducted:Hydrostatic[X]Pneumatic[]NominalOperatingPressure(ISLT)[X]Other.VT1[]VT2[X]VT3[]ISLTaYS.PSIGTestTemp.sYsTEMFHOLDTIMEHYDRO-10MIN.O100PSIGHoldTimeIsLT-4HRs PSL-1,NIS-2TRACKINGNO.SL-2-8-63FORMNIS-2(Back)Sheet2of9.RemarksIsLTwAssATlsFAGTQRILYPERFQRMEDFoRTHEFLANGEDcoNNEGTIQNs.HUDROSTATICTESTWASSATISFACTORILYPERFORMEDONTHEWELDEDJOINTS.10.InspectionReportNumbers:M95-198ANDM95-309APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X)ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizatiNoN/ASignedwnersorOwnei'sDesignee,TitleDateCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;13startingon12/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissions~r>~lNationalBoard,State,ProvidenceandEndorsementsDate<9~4 PSL-2,NIS-2TRACKINGNO.SL-2-8-65FORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/27/95Sheet:Iof2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:7709WO&#xb9;:95010521-1AWCD&#xb9;:N/A4.(a)IdentificationofSystemSTEAMGENERATOR(b)ComponentIdentification2BCOLDLEGHANDHOLE(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:I5.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialHELI-COILSA479NameofManufacturerABB/CEManufacturerSerialorHeatNo.HEAT&#xb9;51892NationalBoardNo.N/AOtherIdentificationUTC385001RIR3AF-2278YearReplacedBuiltRepairedorReplacement1992REPAIREDASMECodeStamped(YorN)7.DescriptionOfWork:ENGINEERINGPROCEEDURE'EP-9448-CSE91-2131ADDRESSESTHEREPAIROFSTUDHOLESWITHTHEUSEOFHELICOILINSERTS.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]NominalOperatingPressure(ISLT)[X]VT3[]sYsTEMPSIGTestTemp.sYBTEMFHoldTime4HDURs PSL-1,NIS-2TRACKINGNO.SL-2-8-65FORMNIS-2(Back)Sheet2of9.RemarksANIsLTwAssUGGEssFULLYPERFQRMEDANDwlTNEssEDBYACERTIFIEDVT-2Q.C.INSPECTOR10.InspectionReportNumbers:M95495APPLICABLEMANUFACTURER'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[X)Repair[]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizatioNoN/ASignedBrsorOwner'sDesignee,TitleDateCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwneCsReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindadsingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate19~(
: 9. Remarks:         A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
PSL-1,NIS-2TRACKINGNO.SL-2-2-FpFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2HCV-36573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/29/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NA'WO&#xb9;:2389WO&#xb9;:95001683-01CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII74Ed./Sum76AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialaeriscShaftAssemblyaeriscShaftAssemblyangetus1X8unc2Aangeus1X8unc2ANameofManufactureramesurryCorp.amesuriyCorp.awovaManufacturerSerialorHeatNo.enaoRKG-1eato8090323NationalBoardNo.OtherIdentificationGfCF8M351GrCF8MA19Gr87S93Gr87YearBuiltReplacedRepairedorReplacementepaceepacementepaceepacementASMECodeStampedPorN)7.DescriptionofWork:Replaceddiscassemblyandflangebolting->~+P~PlcLrs-'d+g~en+lm~gc8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other.VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORIINIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinseiviceleakagetestwasperformedandwitnessedbyaVT-2certiTiedinspector.10.InspectionReportNumbers:MM95-1893APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedM~a.P~Gum-t~fnerOwnei'sDesignee,TitleCaIeIOguS~CIg~TCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignat'e/CommissionsNationalBoard,State,ProvidenceandEndorsementsDate19WJ
: 10. Inspection Report Numbers:
~0~~0~~~~I~~~~~~~~~l~\~~.~~~~~~~~~~'~~~~~~\~P~~I~~I~~~~~I~I~~I~~~~II~~~~P~~~~~~~II~~~~~'~~~~~~~~~~~~~~~
APPLICABLE MANUFACTURES DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
FORMN2(back)DestgnreportcertltiedbyN/ACERTIFICATEOFDESIGNDesignspecificationscertifiedbyT.L.KettlesNYP.E.stateRag.no.'/AN/AP.FstateReg.no.CERTIFICATEOFSHOPCOMPLIANCEWecertifythatthestatementsmadeInthisreportarecorrectandthatthisphase)conformtotherulesotconstructionottheASMECode,SectionIII.ASMECertificateofAuthorizationno.October27,1993ExpiresOate~F2.NameNeles-Jamesbury,Inc.~cervlaecosaasenSignedianhariaedyreserasim)ICERTIFICATEOFSHOPINSPECTIONI,theunderslpned,holdinpavalidcommissionIssuedbytheNationalBoardotBoilerandPressureVesselInspectorsandthestateorpro.IncaoiMassachusettsndemployedbyprotectionMutua1ofoorjMAhaveInspectedtheseItemsdescribedInthisdatareportonbestofmyknowledgeandbelief,lheCertificateHolderhasfabricatedthesepartsorappurtSectiontli.Eachpartlistedhasbeenauthorizedforstampingon!hedaleshownabove.By~Ipnlngthiscertilicate,neithertheInspectornorhisemployermakesanywarranty,expressedorImplied,concerningtheequipmentscribedInthisdatareport.Furthermore.neithertheInspectornorhisemployershallbeliableInanymannerforanypersonalInjuryorrtydamageorlossolanytdndarlslnpfromorcowiththisInspection.pactoryMutualSystemsGate~hOHCKtIhiOOCIN)Commissionsy4arked.ImLendorsemontnslatewpew.endno)
Repair
PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2FCV-07-1A3,WorkPerformedBy.FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ContainmentSprayDate:11/28/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:158-295MIWO&#xb9;:3613WO&#xb9;:95002158CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectionIII74Edition/NoAdd.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialae300Ib/8ate300Ib/8NameofManufactureravesooperIndustriesManufacturerSerialorHeatNo.SeaoK272620NationalBoardNo.OtherIdentification4Gr316240Gr316YearBuilt94ReplacedRepairedOI'eplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedgateduetoerosion8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)t.Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:hii~qgQ7gAPPLICABLEMANUFACTURE'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthrizationNo.:N/ASignedrrOwner'sDesignee,Titlepv-ISDate~~19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescdbedinthisOwner'sReportduringoperatingcyclef/8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertiTicateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-68FPLFORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.PlantFloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957Date:12/27/95Sheet:IUnit:2P.O.f/:N/APCM&#xb9;:N/ANPWOf/:7709of23.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957WOjj:95010521-1A&01WCDf/:N/A4.(a)IdentificationofSystemSTEAMGENERATOR(b)ComponentIdentification28COLDLEGHANDHOLEBOLTING(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:15.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)STUD-SA1931"-8UNC2AX6"STUD-SA1931"-8UNC2AX6"NUT-SA1931"-8UNCABB/CECOMBUSTIONENGINEERINGCOMBUSTIONENGINEERINGHEAT&#xb9;85689HEAT&#xb9;85689HEAT&#xb9;215272N/AN/AN/AUTC314658RIR1H-1524UTC314658RIR1H-2360UTC314662RIR1H-2360199219831983ReplacementReplacementReplacementNONONO7.DescriptionOfWork:BOLTINGMATERIALREPLACEDBECAUSEOFONEBROKENSTUDANDNORMALWEARANDTEARONTHREADSOFANOTHER8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumaticf]NominalOperatingPressure(ISLT)[X]VT3[]SYSTEMPSIGTestTemp.sysTEMFHoldTime4HQURs
                                                                                                          +   Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed      I    8er or uP 'SiL  PLli er's Designee, Title SdPV        IS  1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectoi's Signature                                      National Board, State, Providence and Endorsements Date


PSL-1,NIS-2TRACKINGNO.SL-2-8-68FORMNIS-2(Back)Sheet2of9.RemarksANISLTWASSUCCESSFULLYPERFORMEDANDWITNESSEDBYACERTIFIEDVT-2Q.C.INSPECTOR10.InspectionReportNumbers:M95<95APPLICABLEMANUFACTURER'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizatioNoN/ASignedersorOwner'sDesignee,TitleDateZ~,19~&CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyclef/8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-69FORMNIS-2OiVNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.PlantFloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957Date:12/27/95Sheet:1Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:7709of23.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957WO&#xb9;:95010526-01WCD&#xb9;:N/A4.(a)IdentificationofSystemSTEAMGENERATOR(b)ComponentIdentification2AHOTLEGHANDHOLEBOLTING(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:15.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofNameofComponentorManufacturerMaterialManufacturerSerialorHeatNo.NationalBoardNo.OtherYearIdentificationBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)NUT-SA1931"-8UNCSTUD-SA1931"-8UNC2AX6"COMBUSTIONENGINEERINGCOMBUSTIONENGINEERINGHEAT&#xb9;215272HEAT&#xb9;85689N/AN/AUTC314662RIR1H-2360UTC314658RIR1H-236019831983ReplacementReplacementNO7.DescriptionOfWork:BOLTINGMATERIALREPLACEDBECAUSEOFWORNTHREADSDUETONORMALWEARANDTEAR.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]NominalOperatingPressure(ISLT)[X]VT3[]sYsTEMPSIGTestTemp.sYsTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-69FORMNIS-2(Back)Sheet2of9.RemarksANISLTWASSUCCESSFULLYPERFORMEDANDWITNESSEDBYACERTIFIEDVT-2Q.C.INSPECTOR10.InspectionReportNumbers:M95-497APPLICABLEMANUFACTVREIrsDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthortionNoN/ASignedOwnersorOwnersDesignee,TitleDate/Z>7,199'5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyde&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertiTicateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NtS-2TRACKtNGNO.SL-2-8-~070F~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucioNuclearPlant6501SouthHwy.A1AJcnsenBcach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1V32173WorkPerformedBy'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdcnQicationofSystem:SafetyInjectionDate:1/22/96Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4894WO&#xb9;:95025593CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEC.III;1974ED.;S74ADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)DISCDISCWESTINGHOUSES/N-2025WESTINGHOUSES/N4499NANASA182GR.F316SA182GR.F316NANAReplacedReplacementBONNETNUTSALLIEDHT&#xb9;500260NASA453GR660NAReplacement7.DescriptionofWork:REPLACEDISCASSEMBLY8BONNETNUTSDUETOWEAR.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(tSLT)XOther:VT1XVT2XVT3~PsigTestTemP.~'P PSL-2,NIS-2TRACKINGNO.SL-2C-~070FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVTCERTIFIEDINSPECTOR.10.InspectionReportNumbers:MM95-1692&1694(VT1)I7I7AR4-IS.SCUING.)APPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned~PL/i.fat~gVPV,tSIOwnOwner'sDesignee,TitleDateAtlotk19l4CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsernentsDate PSL-1,NtS-2TRACKtNGNO.SL-2-8-~871FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1-V32254.(a)IdenQicationofsystem:SafetyInjectionDate:11/14/95Slleet;1,ofUnit:2P.O.&#xb9;:5342PCM&#xb9;:NAPWO&#xb9;:5324WO&#xb9;:95031268CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEcrIII1980Eomoii/W80ADDCodeCase:None(b)ApplicablcEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialWeldRepairBonnetNameofManufacturerNAManufacturerSerialorHeatNo.HtNoCT61000434NationalBoardNo.NAOtherIdentificationP8ToP8SA182TR316YearBuiltNAReplacedRepairedorReplacementRepairedASMECodeStamped(YorN)7.DescriptionofWork:Weldrepairbonnetpressuresealarea.8.TestsConducted:Hydrostatic~PneumaticNominatOperatingPressure(tSLT)XOtherVT1VT2XVT3~psigTestTemp.~'P
PSL-1, NIS-2 TRACKING NO.           SL-2                                     FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F PL                                    SUPPLEMENTAL SHEET
: 1. Owner:                 Florida Power & Light Co.                 Date:   12/6/95 P.O. Box 529100 Miami, FL 33152                    Sheet:             3 of  3
: 2. Plant:               St. Lucie Plant                  Unit &#xb9;:
6501 South Hwy. A1A Jensen Beach, FL 34957              P.O. &#xb9;:             NA
: 3. Work Performed By: Florida Power & Light Co.               PCM    &#xb9;:       NA 6501 South Hwy. A1A
, 6. Identification of Components  Repaired or Replaced and Replacement Components:
National                            Replaced      ASME Name of            Name of          Manufacturer                      Other        Year Serial or Heat    Board                              Repaired      Code Component          Manufacturer                                    Identification  Built No.         No.                                   or      Stamped Replacement  (Yor N) isc nse          ros y ave            ena    o                                            ep ace (V8208)                           N91 608-31-0012                    Gr 651 isc nse          ros y ave            ena    o                                          ep acemen (V8208)                          N91 608-34-0031                    Gr 651 pin e ssy          ros y ave            ena    o                                            ep ace (V8208)                           K57208-33-0419                    Gr B6 pin e ssy          ros y  ave          ena    o                                          ep acemen (V8208)                           K5720849-0117                      Gr B6 isc nse          ros y ave            ena o                                              ep ace (V8207)                           N 91608-31-0011                    Gr 651 isc nse          ros y ave            ena o                                            ep acemen (V8207)                          N91 608-34-0029                    Gr 651 pin e ssy          ros y  ave          ena    o                                            ep ace (V8207)                          K57208-38-0148                    Gr B6 pin e ssy          ros y  ave          ena    o                                          ep acemen (V8207)                           K57208<9-0121                      Gr B6 isc nse          ros y  ave          ena    o                                            ep ace (V8213)                           N 91608-31-0006                    Gr 651 isc nse          ros y  ave          ena    o                                          ep acemen (V8213)                           N 91608-34-0028                    Gr 651 pin e ssy          ros y ave            ena    o                                            ep ace (V8213)                           K57208-38-0140                    Gr B6 pin e ssy          ros y  ave          ena    o                                          ep acemen (V8213)                           K5720849-0111                      Gr B6


PSL-2,NIS-2TRACKINGNO.SL-2-0-~071FORMNIS-2(Back)'heet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbeis:g$Wg'.j7g8'SAPPLICABLEMANUFACTURESOATAREPORTSToBEATTACHEDCertiTicateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.XRepairReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedS~PV-LS)OwiIerorer'sDesignee,TitleDate~llNt.,190L2CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.tnspectol'sSignatureCommissionsNB7719FLCom440-~pNationalBoard,State,ProvidenceandEndorsements PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNERISREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St;-LucieNuclearPlant6501SouthHwy.AIA'ensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:11/20/95Sheet:IofUnit:2P.o.f/:NAPCM/f:NAPWO/f:1118WOf/:94015104CWOkNAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2MV09-114.(a)IdentificationofSystem:FeedwaterTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEcTIII1974EomoNNoAooEttoACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialaveug4"/600Ibaveug4"/600IbNameofManufacturerncorDarlingManufacturerSerialorHeatNo.00000379151NationalBoardNo.OtherIdentificationTP31649TP316YearBuilt90ReplacedRepairedorReplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedplugduetodamagedseatingsurface8.TestsConducted:HydrostaticOther:VT1PneumaticNominalOperatingPressure(ISLT)VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-9-FORMNIS-2(Back)Sheet2of29.RemarksAsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:'r'<%giO-Z4O~APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedtKPPmmiSOPV-ls'IneOwnei'sDesignee,TitleDateILDVQD19RECERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwnei'sReportduringoperatingcycle&startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsements PSL-1,NtS-2TRACKINGNO.SL-2-8-~374~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucicNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)'(c)CodeClass:2V091574'Aux.FdWtr.CHECKVLV3.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.,(a)IdentificationofSystem:FeedwaterDate:12/12/95Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3640Wo&#xb9;.94025096CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;CL21974ED.-'76ADD.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialDISC(FOR4'HECKVALVE)NameofManufacturerCONTROLCOMPONENTSManufacturerSerialorHeatNo.S/N:M336830NationalBoardNo.NAOtherIdentificationSA216;GR.WCBYearBuiltNAReplacedRepairedofReplacementReplacementASMECodeStamped(YorN)3/4'-10UNC2AALLTHREAD3/4-10UNC28HEAVYHEXNUTSALLIEDNUT&BOLALLIEDNUT&BOLHT&#xb9;88147HT&#xb9;E04277NANASA193;GR87NANASA194;GR2HNAReplacementReplacement7.DescriptionofWork:REPLACEDISCDUETOWEAR.REPLACEBOLTINGDUETOCORROSION3.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(tSLT)XOther:VT1VT2XVT3~psigTestTemp.~'P PSL-2,NIS-2TRACKINGNO.SL-2-9-~074FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:ivytv'4-VlgAPPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSRupv.-IS(rorOwner'sDesignee,TitleDaIe~EC.I'819~1CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-075FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRcquircdbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:FloridaPowerkLightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V34143WorkPerformedBy'loridaPowerkLightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:1/22/96Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3640WO&#xb9;:95003428CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;1971ED.;S74ADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)DISCASSEMBLYTARGETROCKNANASA479TQ47/3481976ReplacedDISCASSEMBLYTARGETROCKNASA479T-347/348NAReplacement7.DescriptionofWork:REPLACEDISCDUETOWEAR8.TestsConducted:Hydrostatic~PneumaticNominatOperatingPressure(ISLT)XOther.VT1VT2XVTS~psigTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-9-~070FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:MM95-2351APPUCABLEMANUFAC1URESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AsignedL+~PL&ZDI~0orOwner'sDesignee,TitleDate~aeA~2,19~4CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureEDCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate94,19~
CROSBY VA l VK                          6)    BABK          CO 8 PANY W  II  ENTHAM        ~   MASS                          Q.C.AQUA FORM N-2 N OR NPT CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code, Section III, Division 1 Not to Exceed One Day'a Producdon                                          Pg~of~
PSL-2,NIS-2TRACKINGNO.SL-2-8-76FPLFORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.PlantFloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957Date:12/19/95Sheet:IUnit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8220of23.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957WO&#xb9;:95013790-1AWCD&#xb9;:N/A4.(a)IdentificationofSystemSAFETYINJECTION(b)ComponentIdentificationSUPPORTSI4201-7760(MarkNumber)SNUBBER2467TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:15.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterial'BRACKET,PT&#xb9;BEA22-11A-10NameofManufacturerNAVCOManufacturerSerialorHeatNo.SERIAL&#xb9;5623-30NationalBoardNo.NIAOtherYearIdentificationBuiltUTC3815361983ReplacedASMECodeRepairedorStampedReplacement(YorN)REPACEMENT7.DESCRIPTIONOFWORK:ASFOUNDCONDITIONDIDNOTMATCHDWG.INSTALLNEWPARTPERDWG.&ASBUILDASREQUIRED.8.TestConducted:Hydrostatic[]Other.VT1[]VT2[]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)f]PSIGTestTemp.FHoldTime PSL-1,NIS-2TRACKINGNO.SL-2-8-76FORMNIS-2(Back)Sheet2of9.RemarksAFINALVISUALEXAMWASPERFORMEDBYAVT-3CERTIFIEDINSPECTOR.10.InspectionReportNumbers:95-PSL-2067APPLICABLEMANUFACTURER'SDATAREPORTSTOBEATTACHE0CertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/AOwnersorOwnsDesiee,TitleDate)Elf~I,19'ERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyclef/8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignaureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL.2,NIS-2TRACKINGNOSL-2.8.~077FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucicNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:3/8/96Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5377WO&#xb9;:95031723CWO&#xb9;:NAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1V12344.(a)IdentificationofSystem:ReactorCoolantTypeCodeSymbolStampN/AAuthorizationNo,N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESECTIONIII;71'D.-W'73ADD.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialSTUDS7/8'-9UNC2ANUTS7/8'9UNC2BNameofManufacturerALLIEDALLIEDManufacturerSerialorHeatNo.52825-DFNU312565NationalBoardNo.NAOtherIdentificationSA193,BjSA194GR2HYearBuiltNANA'eplacedRepairedorReplacementReplacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:REPLACEBLINDFLANGEBOLTINGDOWNSTREAMOF2DRAINVALVEDUETOHEAVYCORROSION.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLTIXOther;VTIXVT2XVT3~[PstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-24-~077FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONOFTHENEWBOLTING(VT1)ANDA'N'NSPECTIONNFORLEAKAGE(VT2)WASPERFORMED.10.InspectionReportNumbers:MM95-1771&MM95-2484APPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedAs<<ap~S~e~-ISiCaIe>I27erorai'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCo.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;329NationalBoard,State,ProvidenceandEndorsementsDate
~ Manufactured and oertIIIed by          Crosb      Valve    8( Ga e Co.         43 Kendrick        St. Wrentham      MA  02  3 (name and addresa of certilicate holder) .
Man+act redfor        Florida    Power      8  Li ht    C      P.O.Box 029950            H  ami        L      02 (name and addresa of pllrchaser)
St.Lucie Plant PSL-972                6501 South A1A Jensen              Beach      FL 34957 (name and address)
(dra))vinyl na}              (fMflspec  no.)       (tenace atrength}          (CRH)
AS ME Code, Seeuon III          1974                          NO                          2 (ed Non)                   (addenda)                     (class)
Fabricated ln acoordance with Const. Spec. (Dlv. 2 only)                                                       Date (Ho.}
. Remarks:
                                                                        'i I R      j= -37'- 2
. tenn. nrtekneee gn.)             kttn. dec)go thteknene gn.)           t))h ID (rk hkk)           length overall (L h kk)
. Whan applcable, Certificate      Holders'ata reports are attached for each Item of this report National                                                              Natfc)nal Board No.                                                             Board Ho.
In Numerical Order                                                      In Numerical Order N91608-34-0028 (2)  N91608-34-0029                                                      (12)
(3)   N91608-34-0030                                                      (13)
(4)   N91608-34-0031                                                      (I4)
(6)                                                                       (16)
(8)                                                                       (18)
(9)                                                                       (19)
: 10)                                                                     (2o)
: p. Design pressure                    psi Temp.                   'F  Hydro. test pressure                  at temp. F.
(when applicable)


PSL-1,NIS-2TI2ACKINGNO.SL-2-8-~078gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystemSNUBBERSDate:12/8/95Sheet:Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:91-8220WO&#xb9;:VARIOUSCWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(b)Component2-039,2-046Identification:2-066,2-067(MarkNumber)2p842p88(c)CodeClass:ALL2125,215p2-156a)ApplicableConstructionCodeandAddenda:ASMESEC.III;1977EDTHRU'79ADD.(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialPSA1/4SNUBBER:2439PSA1/4SNUBBER:2446PSA10SNUBBER:2-066PSA10SNUBBER:2467PSA3SNUBBER2484PSA1SNUBBER2-088NameofManufacturerPACIFICSCIENTIFICPACIFICSCIENTIFICPACIFICSCIENTIFICPAC.SCIENTICLISEGA3062RF1PACIFICSCIENTIFICPACIFICSCIENTIFICManufacturerSerialorHeatNo.S/N38499(OLD)S/N38503(NEW)S/N11832(OLD)S/N38510(NEW)S/N17848(OLD)S/N16610(NEW)s/N12848IQLo)s/N81256/32INEw)S/N29504(OLD)S/N24747(NEW)S/N7419(OLD)S/N12289(NEW)NationalBoardNo.NANANANA'AOtherIdentificationWO&#xb9;9501375841WO&#xb9;9501378541WO&#xb9;9501378741WO&#xb9;950137904WO&#xb9;9501371541WO&#xb9;9501378841YearBuiltNANANANAReplacedRepairedofReplacementReplacementReplacementReplacementRepIacementRepIacementReplacementASMECodeStamped(YorN)7.DescriptionofWork:REPLACESNUBBERSDUETOTESTFAILURES.REFERTOINDIVIDUALWORKORDERSFORSPECIFICDETAILS.s8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3X~psigTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~078FORMNIS-2(Back)Sheet2of39.Remarks:APOSTINSTALLLTIONVT3WASPERFORMEDFORALLSNUBBERS.INFORMATIONRECORDEDONINDIVIDUALVT3INSPECTIONREPORTSONFILE.10.InspectionReportNumbers:VARIOUS.APPLiCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedA'~~Citii@Pt/-IXIOwrorOwner'sDesignee,TitleDate~IS'9~9CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.lnspectoi'sSignatreCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-~078FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXIPLSUPPLEMENTALSHEET1.Owner:FloridaPower&LightCo.P.O.Box529100Mami,FL33152Date:12/8/95Sheet:3of32.Plant:St.LuciePlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPowerkLightCo.6501SouthHwy.A1AUnit&#xb9;:2P.O.&#xb9;:NAPCM&#xb9;:NA6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)PSA1/4SNUBBER2-125PSA1SNUBBER2-150A1SNUBBER2-156PACIFICSCIENTIFICPACIFICSCIENTIFICPACIFICSCIENTIFICS/N37659(OLD)S/N38489(NEW)S/N14880(OLD)S/N26002(NEW)S/N12790(OLD)S/N26008(NEW)NANANAWOO9501376941WOII95013771ZIWot/9501375941NAREPLACEMENTNAREPLACEMENTNAREPLACEMENT PSL-1,NIS-2TRACKINGNO.SL-2-8-~gyp~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucicNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2MV-08-19B3.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:1/2/96Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:WO&#xb9;:94025103CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;1980ED.NOADDENDACodeCase:None(b)ApplicablcEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedofReplacementASMECodeStamped(YorN)PLUGASSEMBLY10'12'LUGASSEMBLY10X12BONNETSTUDS11/4NUNX71/4BONNETNUT11/4-8UN2BPACIFICVALVECONTROLCOMPONENTSCONTROLCOMPONENTSNOVAMACHINENAS/N360270HT&#xb9;23150BHT&#xb9;8099455NASA182GRF111980NASA182GRF111992NASA193GRB7NANASA194GR2HNARep'lacedReplacementReplacementReplacement7.DescriptionofWork:REPLACEPLUGASSEMBLYDUETOSTEAMCUTTING.STUDS8NUTSREPLACEDDUETOCORROSION.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLTIXOther:VT1VT2XVT8~pstgTestTemp.~'P PSL-2,NIS-2TRACKINGNO.SL-2-8-~079FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKGEWASPERFORMEDANDWITNESSEDBYAVT2INSPECTOR.10.InspectionReportNumbers:IMM951777(VTI}KR&(L6~i)APPLICAB(.EMANUFACTuRESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementiTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedOwrorOwnDesignee,TitleCate~I~,19~4CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition~noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.C'57InspectoVsSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State.ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/1/95Sheet:Iof3Unit:P,O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3572WO&#xb9;:95001867CWO&#xb9;:NAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3SS-21-1B4.(a)IdentificationofSystem:ComponentCoolingWaterTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialtuover1"-Suncx6'Cover1-Suncx6utCover1-Suncutover1'-8uncfT'i%9%13/4x10uncx51/23/4x10uncx51/2NameofManufacturerumIndustriesovaMachineumIndustriesheutBolturnIndustriesovaMachineManufacturerSerialorHeatNo.eato8090323eato090309eato8078372NationalBoardNo.AOtherIdentificationGrB793GrB794Gr2H9Gr2H3GrB793GrB7YearBuiltReplacedRepairedofReplacementepaceRepacementepaceepacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedstrainercoverboltingandhandholeboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of39.Remarks:AsatisfactoryInserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPLICABLEMANUFACTURESOATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedUPV-(s(Date~,19~nernei'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleff8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDateZ-%'
CROSB                          F 4-=c~cc~Ms~$ W                        d.  -g Q.C.-392 SHEE7    1 OF 2 FORM N-2, N OR NPT CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code, Section III, Division I - Not to Exceed One Day's Production
PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OiVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIFPLSUPPLEMENTALSHEET1.Owner:FloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/1/95Sheet:3of32.Plant:St.LuciePlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AUnit&#xb9;:2P.O.&#xb9;:NAPCM&#xb9;:NA6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentuanoe3/4"x10unc-2Buanoe3/4x10unc-2BNameofManufacturerurnIndustriesieuBoltManufacturerSerialorHeatNo.eaoE04277NationalBoardNo.OtherIdentificationGr2HGr2HYearBuiltReplacedRepairedorReplacementepaceepacemenASMECodeStamped(YorN)
: 1. Manufactured and certified by (Name and Address of N Cert(f(cate Holder)
PSL-1,NIS-2TRACKINGNO.SL-24-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower'LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3V141473.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ComponentCoolingWaterDate:11/30/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3640WO&#xb9;:95002733CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1974/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentofMaterialave20ae20angeu11/8-8un2Aangetu11/8-Sun2Aangeut11/8-8un28angeut11/8-Sun28NameofManufacturerISSOnauonroe8SawliesawManufacturerSerialorHeatNo./894952%1eato52825eato152550TR053NationalBoardNo.OtherIdentificationGrWCBGrWCBGr873Gr87Gr2HGr87YearBuilt990ReplacedRepairedOI'eplacementepaceepacementepaceepacernentepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedvalveduetosealdamageandflangeboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.
: 2. Manufactured for          FLORIDA POWER & LIGHT CO.
(Name and Address of Purchaser or Owner)
: 3. Location of Installation  ST.LUCIE (Name and Address) 4,                                         DS-C-59335 REV.C                                                1995 (CRN)                     (Drawing No.)                                               (Year Built)
: 5. ASTIVI A458 GR,651                                                REIVIAR S (Material Spec No.)                               (Tensile Strength)
: 6.                               Nom. Thickness(in.)                        Mln. Design Thickness Dia. ID    Length Overall                                Inch                                            Inch DF 7.
Design Pressure(PSI)                                             Temperature Hydrostatic Test (psig)                             at                      oF (When applicable)
: 8. Fabricated in accordance with Const. Spec.(Div. 2      only)        Revision        Date (No.)
: 9. ASME Code, Section III, Division 1: 1974                  NO (Edition)        (Addenda Date)               (Class)         (Code Case No.)
: 10. Remarks      TENSILE MIN:95 000
: 11. When applicable; Certificate Holders'ata reports are attached for each item of this report:
Part or Appurtenance            National                Part or Appurtenance>>          National Serial Number                Board No.                   Serial Number              Board No.
Numerical Order                                          Numerical Order (1)      N91 608-34-0027                                (11)
(2)                                                     (12)
(3)                                                     (13)
(4)                                                     (14)
(6)                                                     ('l5) l6)                                                      (16)
(7)                                                     (17)
(8)                                                     (18)
(9)                                                     (19)
(10)                                                     (20)


PSL-2,NIS-2TRACKINGNO.SL-24-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:tliriigQ5"Q.SpfAPPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedca2PLeurUoovIsio,<<IVovEoIg~qnerowner'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2N-082~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miam,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2FCV-25-363WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ContainmentPurgeDate:12/14/95Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5205WO&#xb9;:95029884CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1977Ed/Noadd.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialWafer(Disc)Wafer(Disc)NameofManufacturerControlmaticsControtmaticsManufacturerSerialorHeatNo.NFHeatNo8383726NationalBoardNo.NANAOtherIdentificationASMESA516Gr70ASMESA516Gr70YearBuilt,ReplacedRepairedorReplacementReplacedReplacementASMECodeStamped(YorN)7.DescriptionofWork:Replaceddiscduetowear8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressureitgLT)Other:VT1VT2VT3~psigTestTemp.'F
Q.C.-392 Manufacturer Serial No.     N91 608-34-0027                      SHEE7 2 OF 2 CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this(these) conform to the rules of construction of the ASME Cade. Section III.
Date    2                  S        Signed (NptCertificate Holder)            (Authorized Repr sentative)
Expires  ~~~~
(Date)
CERTIFICATE OF DESIGN Design specification certified by" PE  State                          Reg No.
Design Report Certified by'E State                          Reg No.
                    'Signature not required - list name only.
CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel of                                        have inspected these items described in this Data Report on has fabricated these parts ar appurtenances in accordance with the ASME Code, Section III. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warrant, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from ar connected with this inspection.
Date                          1B 1>.
Signed                                                  Commissions (Inspector)                                           (Nat'I. Bd., State, Prov. and No.)
<<Factory Mutual Systems


PSL-2,NIS-2TRACKINGNO.SL-2-8-~082FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYLOCALLEAKRATETESTWASPERFORMED.10.InspectionReportNumbers:OP2-'130051APPLICABLEMANUFACTURE'SOATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AsignedlAdateMPtsan8>PII-ISIneror0eVsDesignee,TitleCate~IN19tI5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPiessureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate 0
    /      ROSR                      r              P
PSL-1,NiS-2TRAOKtNGNO.SL-2C-~083FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miam,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2MV-08-19A4.(a)Iden@icationofSystem:MainSteamDate:12/14/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:1089WO&#xb9;:94025102CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEC.III1980ED;NOADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentol'aterialNameofManufacturerManufacturerSerialorHeatNo.NAPLUGASSEMBLY11/4NUN-2BBOONETNUTCONTROLCOMPONENTSSN&#xb9;:360270ALLIEDNUT&BOLHT&#xb9;E97187PLUGASSEMBLYPACIFICVALVENationalBoardNo.NANAOtherIdentificationYearBuiltSA182GRF-111980SA182GRF111992SA194;GR2HNAReplacedRepairedorReplacementReplacedReplacementReplacementASMECodeStamped(YorN)11/4WUN2AALLTHREADALLIEDNUT&BOLHT&#xb9;62413NASA193;GRB7NAReplacement7.DescriptionofWork:REPLACEBOLTINGANDPLUGDUETOSTEAMCUTIINGANDCORRODEDBOLTING8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther.VT1VT2XVT3~psigTestTetep.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-083FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:Ph)'hfCI."I)APPUCABLEMANUFACTURE'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedvmeroreVsDesignee,Titlert/SIDate~tZIttt~5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningthe'examinationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectoVSSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate19~>
                                                      ~   a<73Ol>
FORMN-2CERTIFICATEHOLDERS'ATAREPORTFORIDENTICALNUCLEARPARTSANDAPPURTENA/ACES>>AsRequiredbytheProvisionsoftheASMECode,SectionIIINottoExceedOneDay'sProdtrctionPg.1of2H/AN/A(CadeCseeca,)NIA1.Manut>>nceedandcecal>>dbyContestCanfronerrfthc.2259tAtwicfdGnprdddAvaboSarrgth4aryarttd.CA92688hens>>ncaddressdosrcna>>eHcsdcrl2.MenufactcsedforFLORIDAPOWERAIVDUGHT.RATPIERCE.FLORIDAhsn>>cndeddcssecrCcneseci3.LocationofhstattaaonST.L(IDIEPLANT.(WIT2,FORTPIERCE.FLORIDAhensendaddress)i.Type82060I612XX'A182-Pff70,000PSI1992(dnssnenca)hc>>l>>ace.na}(te>>secrenateftttrr)5.ItsMEcode,seclonttLoansion1:f980NO(sdtasc)tLFabricatedhaccocclancesettconsLspec.(oN.2only)N/Asw'e'encvADanha)T.ecnsstacaFDRMCD(JLATIs1/ENTDRAGVALVE/N26689-ICgf)1/C4C6f11f1-fPL(AeWC''850270rLNorafftctcr>>rs(st,)2.8Mh.deigntnictcness0rL)N/AOta0(ftSh)1.4'angatowait(ftSh)12.6'.vtr>>napptcabte.CerttccateHolders'DataReportaareattacnedforeachfhmoftntareportHabcealSwdHcLinNwnencatOrderPartorApca>>enate>>SerialNcanberNatlondBoardNcLhNcanencatOrder860270BH1(2.)8602708/H2p.)(4)(5)(a)(7)(fL)(0)(ftL)(11.){12.)(13.)(14.)(15.)(1tL)(17.)(15.){10.)(30.)'3$.)(22)(23.)(34)(35)(2tL)(27)(2tL)(2(L)pg.)P1.)(32)(33.)pi.)p5.)(3tL)pl.)PfL)Pg.)(4tL)(41.)(42.)(43.)(aa)(45.){atL)(47.)(45)(40.)(50.)10.OeeignpresscseQ5$pa.Temp.660oeg.FHydrccastpreeaaeN/A'tacmp.oeg.F~ftuPPlenarearannSOCCnht>>rC>>nefaCCS.Ckcaear>>e.CrdnaaCnten>>rbeueedCCCCSted(1)Saeb~tftatl.(g)idrnn>>arChlaneaendaCSCtWOPSftCPCCtbhcacdedcneedcd>>dgsensed>>>>bsera>>csd>>nttwrsscca>>rod>>ccsbcascadedelteetcpdtenfccnn.Triafarmg05a)cnerbecbtahedecsnheCederOsPCASLE22LeesOrtsaBcscs&#xc3;ZLFee>>ecclfafOWtr2XXLPagez3 N-2FORMN-2plack-Pg.2a~2csrgycohHokeer'sserialetoa.XC2SehroctgerSrN182~eoeoehrcknoensedbyKN.CHOWIEareRsag,caratIs-suehVAsea.naN/Ateaoerd1hdfly~madehtlk~coeocnosandtiphtathesee~coheasaeetocnerakakncahestagecode.secckns.Qklaans.AlVEF,1854kltIf0~trCOWVROLCCWPCNIENTSJVCl'IIgrace(NrclscLhoaadhctecknwneaeaxe%deorprotaaena)hddhe~oorsnbhm~byheetdknctsacrocdeeoeeroaeprseoaevesselepeoooreendtrediraeorpro@acreetCALIIcURtV14oae~crtoeedbyHARVARDS7K4MBOILERhlSPECTJONANDNSUROVCZCCtMPANYbeetctmyoacedcteoeebasaltre~Headerhasbbtceredtreespensorzgxs~heoooneoars~treAslEcoosjeodcng,crrkicnkSeanpentreedbeebemacrhorkadearecamphcecntwdaceetcwn<<xaasyekyrhpNsoerreketa,natrertwhaoecrorncstscempioyermakeswaarrcnry,etrrsaeeedorhoaec1ocakarmheetraaatencncdarorbedhtriacatsAaocrkycatromae,Moattrehapecrorncknta~nploteranatbatcbl~hany~ear~perscnat~orpropertyreenactsoreoaecdanykhdananpframor~trkhapecckn.Q.t+tR~-+~~'age7af~~
3 ag Io Q.C.-392 SHEET    I OF 2
PSL-2,NIS-2TRACKINGNO.SL-2-8-,84FPLFORMNIS-2OiVIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/18/95Sheet:1of2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8211WO&#xb9;:95012902-01WCD&#xb9;:02044.(a)IdentificationofSystemCOMPONENTCOOLINGiVATER(b)ComponentIdentificationLINEI-20-CIV-97-2(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherYearidentificationBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)PIPE-20"SA106GR.BPIPE-20"SA106GR.BNIATIOGAPIPESUPPLYNIAHEAT&#xb9;L63840N/AN/AN/AUTC371811RIR22764NIA1995REPLACEDREPACEMENTNONO7.DESCRIPTIONOFWORK:12"SECTIONOF20"PIPEREPLACEDBECAUSEOFPIPEWALLREDUCTIONDUETOCORROSION8.TestConducted:Hydrostatic[X]Other:VT1[]VT2[X]Pneumatic[]VT3[]105NominalOperatingPressure(ISLT)[]PSIGTestTemp.sYsTEMFHoldTime10MINUTEs PSL-1,NIS-2TRACKINGNO.SL-2-8-84FORIN'IS-2(Back)Sheet2of9.RemarksAHYDRosTATIcPREssURETEsTwAssuccEssFULLYPERFDRMEDQNTHEWELDEDJOINTSANDWITNESSEDBYAVT-2CERTIFIEDQ.C.INSPECTOR.10.InspectionReportNumbers:M95-425APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[]Replacement[X]ModificationconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwneVSBsigneiticDate~<19[5CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertiTicateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.7i)InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-I,NIS-2TRACKINGNO.SL-2-8-~088FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:FloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:1/4/96Sheet:1of2.Plant:St.LucioNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2CHGPP2A3.WorkPerformedBy.FloridaPopover&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdenSicationofSystemChemical8VolumeControlUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4808WO&#xb9;:95023617CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;'3ED.,'S.'4ADD.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedofReplacementASMECodeStamped(YorN)VALVECOVERNUTNOVAMACHINEHT&#xb9;2FCS76NASA194;GR6NAReplacement7.DescriptionofWork:REPLACEVALVECOVERNUTWHICHWASFOUNDTOBECRACKED.(POSSIBLYOVERTORQUED)8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLTIXOther:VT1VT2XVT3~psigTestTemp.~'F 00 PSL-2,NIS-2TRACKINGNO.SL-2-8<<085FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:~~Ig-Z.4l+APPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementSignednerEUrv.ei'sDesignee,Title,TypeCodeSymbolStamp:N/A'ertificateofAuthorizationNo.:N/AgoDateM19ttCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwneVsReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwneVsReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,rioaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection..gInpectoi'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsOate PSL-2,NIS-2TRACKINGNO.SL-2-8-86FORMNIS-2OiVIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152iSt.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/27/95Sheet:1of2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:7709WO&#xb9;:95010526-01WCD&#xb9;:N/A4.(a)IdentificationofSystemSTEAMGENERATOR(b)ComponentIdentificationMANiVAY,SECONDARYSIDE(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:35.(a)ApplicableConstructionCodeandAddenda:ASME1971S1973ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)STUD-SA5401-1/2"X9"COMBUSTIONENGINEERINGHEAT&#xb9;82158N/AUTC3881241983ReplacementNO7.DescriptionOfWork:BOLTINGMATERIALREPlACEDBECAUSEOFWORNTHREADSDUETONORMALWEARANDTEAR.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[X]Pneumatic[]NominalOperatingPressure(ISLT)[X]VT3[]sYsTEMPSIGTestTemp.sYBTEMFHoldTime4HQURs PSL-1,NIS-2TRACKINGNO.SL-2-8-86FORMNIS-2(Back)Sheet2of9.RemarksANISLTWASSUCCESSFULLYPERFORMEDANDWITNESSEDBYACERTIFIEDVT-2Q.C.INSPECTOR10.InspectionReportNumbers:M95497APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoNlSignedOwnersoOwnei'sDesignee,TitleDate/Z.ZT,19~bCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwnei'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-2-FPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/13/95Sheet:Iof2Unit:P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3638WO&#xb9;:95002817CWO&#xb9;:NAProcessSheet:N/A4.(a)IdentificationofSystem:MainSteam(b)ComponentIdentification:V08163(MarkNumber)(c)CodeClass:3TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1974Ed/S76AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents;TypeofComponentorMaterialaveisc600Ib/4'eisc600Ib/4NameofManufactureraciicaveaciicaveManufacturerSerialorHeatNo.eato26M3NationalBoardNo.OtherIdentificationGrWCB26GrWCBYearBuiltReplacedRepairedOI'eplacementepaceRepacemenASMECodeStamped(YorN)7.DescriptionofWork:Replaceddiscwhichwasdamagedduringdisassembly8.TestsConducted:HydrostaticOther:VT1PneumaticNominalOperatingPressure(ISLT)VT2~VT3psigTestTemp.'F
        -2, N OR NPT CERTIFICATE IIOLMRS'ATAREPORT FOR IDENTICAI.NUCLZARPARTS AND APPURTENANCES I
As Requirsd by tire Provisions of drs AS<YE Cods, Sccnon III, Division - Not to Erossd One Day's Production
: 1. Manufactured sind certified by (Name and Address of N Certificate Holder)
: 2. Manufactured for              FLORlDA POWER          5 LIGHT COMPANY            JENSEN    BEACH FL (Name and Address of Purchaser or Owner)
: 3. Locat(on of installation      LUC(E STORES JE SEN BEACH L (Name and Address)
: a.                                             DS-C-69335 REV. C                                            1995 (CRNI                      (Drawing Na.)                                             (Year Built)
: 6. ASME SA 193 GR. B6                                                    110 000
{Material Spec No.)                                 (Tensile Strength)
: 6.                                   Nom. Thickness((n.)                           Min. Design Thickness Dia. ID    Length Overall                                  inch                                          inch 7.
Design Pressure(PSI)                                               Temperature Hydrostatic Test (psig)                               at                          oF
{When applicable)
: 8. Fabricated in accordance with Const. Spec.{Div. 2 only) -                Revision      Date (No.)
: 9. ASME Code, Section ill, Division 1: 1974                    NO ADDENDA (Edit(an)         (Addenda Date)             (Class)       {Code Case No.l
'l0. Remarks 1'l. When  app{(cab(e, Certif(cate  Holders'ata reports are attached for each item of this report:
Part ar Appurtenance            Net(anal                  Part or Appurtenance        National Serial Number                Board No.                     Serial Number            Board No.
Numerical Order                                        Numerical Order K6720&%9%111                                    {11)
(2)        K57208%9-01 17                                  (12)
(3)       K67208%9%119                                    (13)
(a)       K67208&9%121                                    (1a)
(5)                                                         ('l 6)
(8)                                                         (16)
(7)                                                         ('l7)
(8)                                                         {18)
(9)                                                         (19)
(10)                                                       (20)


PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:N~qcPAPPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AStgaegJl/(!Zl,I5RPVIS(Owneornei'sDesignee,TitleDateZEC(3,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.19S9Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.8.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AlAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2HCV-35123.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/29/95Sheet:1ofUnit:2P.O&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:8958WO&#xb9;:94009167CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII74Ed./Sum76AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialege(Disc)ege(Disc)NameofManufactureramesurryCorp.amesurryCorp.ManufacturerSerialorHeatNo.enaoNJV-2NationalBoardNo.OtherIdentificationGrCFSM3GrCFSMYearBuiltReplacedRepairedOI'eplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replaceddiscduetoleakage.norootcauseidentified.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F
Q.C.-992 Manufacturer Serial No.         K5720&%9-0111                      SHEET,2 OF 2 iR$1~& 0%+bCR4~~                  m rrevaa~~~ s'aa'n~~
CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this(these)       &PINO  "E 4&SEMBIES l"ao3377(
conform to the rules of construction of the ASME Code, Section III.
Vog(g Date                              Signed (NptCertificate Holder)              (Authorized Re    esentative)
Expires ~E~
(Date)
CERTIFICATE OF DESIGN Design speclficatlon certified  by'E State                            Reg No.
Design Report Certlfied by>>
PE  State                            Reg No.
                    <<Signature not required - list name only.
CERTIFICATE OF SHOP INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel of                                        have inspected these items described ln this Data Report on 19~5  and state that to the best of my knowledge and belief. the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section III. Each part listed has been authorized for 'stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warrant, expressed or implied, concerning the component described ln this Data Report. Furthermore, neither the Inspector nor his employer shalt be liable ln any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date                        195' Signed                                                    Commissions (Inspector)                                             (Nat'I. Bd.. State, Prov. and No.)
<<Factory Mutual Systems


PSL-2,NIS-2TRACKINGNO.SL-2-S-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:)5f6QQ-3,5QQAPPLICABLEMANDFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/Asigned(k(sRPieei'Snp"e-(SnerOvineVSDesignee,TitleDate~d2-'f,19LgCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyclef/8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-2.NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/13/95Sheet:Iof2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3624WO&#xb9;:94025119CWO&#xb9;:NAProcessSheet:N/A4.(a)IdentificationofSystem:SafetyInjection(b)ComponentldentiTication:V3468(MarkNumber)(c)CodeClass:2TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)APPlicableConstructionCodeandAddenda:ASMESectlii1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementCompo'nents:TypeofComponentorMaterialnetus5/8-11unc2Anettus5/8-11unc2Anetuts5/8-11unc28netuts5/8-11unc28NameofManufacturer,awovaawieut8~etManufacturerSerialorHeatNo.eato9965663eato97365NationalBoardNo.OtherIdentification3Gr87193Gr87S194Gr2H194Gr2HYearBuiltNAReplacedRepairedofReplacementepaceepacementRepaceRepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedboltingduetocorrosion8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:NNqQnIQgAPPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASIgnedIAcd~pcc-IScOwnerrOwnersDesignee,TitleOnce&~a'.cI,IgagCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-I,NIS-2TRACKINGNO.SL-2-8-~090~FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucioNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2HCV-35123.WorkperformedBy.FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:11/25/95Slicct;1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:179-295MPWO&#xb9;:5488WO&#xb9;:95032597CWO&#xb9;:ProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:NACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandRcplaccmentComponents:TypeofComponentorMaterialFLATBAR1/4X1/2NameofManufacturerFRYSTEELCOManufacturerSerialorHeatNo.HEAT&#xb9;A12060NationalBoardNo.OtherIdentificationSAR79TP316YearBuiltNAReplacedRepairedoi'eplacementReplacedASMECodeStamped(YorN)FILLETWELD3583FPLWELDTRAV&#xb9;95-3583NANA1995NEWWELD7.DescriptionofWork:SECUREPINTOTHEVAVLEDISCBYWELDINGTOPREVENTDISCFROMROTATINGAROUNDSTEM.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLTIXOther.VT1VT2XVT3~psigTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-0-~000FORMNIS-2(Back)Sheet2of29.Remarks:A~w+c4N1~+~4~~l~Q<~1CA'HgegItnz~cS/,10.InspectionReportNumbers:IAN95-Q.9~APPUCABLEMANUFACTURESDATA,REPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.XRepairReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedPb>qg-IS<0erorei'sDesignee,TitleDatePoU~,19CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDatej PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3V081303.WorkPerformedByFloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:MainSteamDate:12/7/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3638WO&#xb9;:94025126CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1974Edition/S75AddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989,Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentoi'aterialISC(4'heck)ISC(4Check)NameofManufactureracIicValvesonroComponentsManufacturerSerialorHeatNo.eatoA0342NationalBoardNo.OtherIdentificationGrWBC26GrWBCYearBuilt199ReplacedRepairedorReplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replaceddiscassemblyduetodamage.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F
PSLQ NIS-2 TRACKING NO.                 SL-2                                                 FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                           Florida Power  & Light Co.               Date:     11/29/95 P.O. Box 529100                          Sheet:      1  of 2 Miami, FL 33152 Unit:
: 2. Plant:                             St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3  Work Performed          By'lorida Power & Light Co.                          PWO    &#xb9;: 3604 6501 South Hwy. AIA WO&#xb9;:       95002731 01 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet:   N/A
: 4. (a) Identification      of System:     Reactor Coolant Type Code Symbol Stamp        N/A Authorization No.           N/A (b) Component                          V1200 Expiration Date          ~
N/A Identification:
(Mark Number)
(c) Code Class:         1 Code Case: None
    ) Applicable Construction Code and Addenda: ASME Sect III 1974 Edition/ No addenda (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification      of Components Repaired or Replaced      and Replacement Components:
Type of                  Name of          Manufacturer      National      Other          Year      Replaced        ASME Component              Manufacturer        Serial or Heat    Board                        Built      Repaired      . Code No.         No. Identification                    or          Stamped OI'aterial                                                                                    Replacement (Y or N) eie      ave          ros y ave            ena o                                                    ep ace
( Code Safety)                              N59336-00-0003                Gr CF8M eie      ave          ros y ave            ena  o          30                          99        ep acement
( Code Safety)                             N 5933641-0002                Gl CF8M
: 7. Description of Work:             Replaced exisiting valve with new spare.
S/N 59336-01-002 (New valve)
: 8. Tests Conducted:             Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig    Test Temp.


PSL-2,NIS-2TRACKINGNO.SL-2Z-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:+WIQ-(3,WAPPLiCABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizatinNo.:N/ASignedELPbattPI/l5Date~,19~OworOwni'esignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorscmentsDate PSL-2.NtS-2TRACtONGNO.SL-2-8-~892gFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3AFWPP2B4.(a)IdenQicationofSystem:AuxiliarySteamDate:1/2/96Sheet:Unit:2P.O.&#xb9;:naPCM&#xb9;:naPWO&#xb9;:2960WO&#xb9;:950103040CWO&#xb9;:ProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;1974ED.,NOADDENDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedOI'eplacementASMECodeStamped(YorN)CAPSCREWSINGERSOLLRANDHEAT&#xb9;94521NASA193;GRB7NAReplacement7.DescriptionofWork:REPLACEBOLTINGDUETOTHREADDAMAGE,.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(18LT)XOther:VT1VT2XVT3~pstgTestTemp.~'P PSL-2,NIS-2TRACKINGNO.SL-2-8-~092FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:IvtreQgAPPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedSUV-IGOvmrOvmer'sOestgnee,TitleDate819Q4CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate0K1954 PSL-1,NIS-2TRACKINGNO.SL-2-8-rPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:MV0914(MarkNumber)(c)CodeClass:33WorkPerformedBy'.FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:FeedwaterDate:12/12/95Sheet:IofiUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5075WO&#xb9;:95028673CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectlli1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialonnetuts5/8x11unc2Bonnetuts5/8x11unc2Bonnettus5/8x11unc2Bonneus5/8'11unc2BNameofManufactureraaicvaveIeutotaaicaveovaManufacturerSerialorHeatNo.eatnoL63812eato62477NationalBoardNo.OtherIdentificationGR7A94GR7AAA9,3GrB7GrB7YearBuiltReplacedRepairedorReplacementepaceepacementepaceepacemenASMECodeStamped(YorN)7.DescriptionofWork:Replacedboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F
PSL-2, NIS-2 TRACKING NO.                 SL-2                                                  FORM NIS-2 (Back)                                       Sheet 2 of    2
: 9. Remarks:         A satisfactory insewice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. inepeoiionReportNombem:         lnNR5          Q lip/p APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATI'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                          +   Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signeo          Sf'R.
ne or Puceol nei's Designee, Title v'. I 6I            Date MCt/    '- f,19~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspactols Signature                                      National Board, State, Providence and Endorsements Date


PSL-2,NIS-2TRACKINGNO.SL-2-2-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:g~t52-E~APPLICABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedneoOwner'sDesignee,TitleDetect'+19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableInanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.a/Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsements,19~
GROS BY YA LVE                          8 GAGED              CO    M  PALY W  It  KIITHAM MASS  ~
PSL-I,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:MV0913(MarkNumber)(c)CodeClass:33WorkPerformedBy'loridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL349574.(a)IdentificationofSystem:FeedwaterDate:12/12/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5074WO&#xb9;:95028672CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1989Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialonnetuts5/8'11unc2Bonnetuts5/8'11unc2BBonnettus5/8'11unc2BNameofManufactureraciicaveieUtotPaciicaeManufacturerSerialorHeatNo.eatnoL63812NationalBoardNo.OtherIdentificationGR7GR7GrB7YearBuiltReplacedRepairedofReplacementepaceepacementepaceASMECodeStamped(YorN)honnnetates5/8x11unc2BNovaeato62477GrB793epacement7.DescriptionofWork:Replacedboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F
O.C..CCC ~
IF 9XXa 1
FORM MV-1 FOR SAFETY ANG SAFEtY REI.IEF VALVES r<<quired by the provisions of the AsME Code Rules Pate~et I<>                                                      DATA REPORT Safety and Safety Relief ValveS
'l. Manufactured      By      eros    valve    IL ca e co. 43 rendrick street      wrenthan  Ka 02093 Name arx$  Address HB-BP-86                        N28017 Model Mo.                    order    Mo.                           Contract Gate                        Maticnsl aboard Mo.
: 2. Manufactured For          =        da    o e                                                      Order No.
Name  and Address Florida        Power    ie  Light      Co. P.O.Box 029950              Miami,FL 33102 Name  and Addrcs
: 4. Location of Plant            St.Lucie Stores-PSL-972                  6501 South A1A Jensen            Beach FL 34957
: 5. Valve Idcntif icaticn          SPARE                      Serial    No. N59336-01-0002            Graving No. DS-C-59336-1 Rev.
Type    Saf et                                              Orifice Size      1 ~ 531 Safety, Safety Relief, Pilot, Pover Actuated                                    Inch              Inch          Inch            Inch
: 6. Sct Pressure (PSIG)             2485                                                    Desi  ~  '      . 700 F Rated T~rature 0
F Scaeped Capacity      212 182 LBS HR Steam a                      3      X Overpresure          Biovdovn (Pslr)     15X  of  SP Kydroscacic Test (PSIC)         Inlet            3750                        Cpiece valve                  750
: 7. The ceceriai      ~ design, construction and vorkmanship          c~ly vith AWE Code,      Section  III.
Class        1              calcic        1974        , Addenda Gate        No                            ~ Case Mo.
Serial No.                         Material Specification
: a. Castings                                          ident i f ication                    including Type or Grade K60802-36-0009 Barnet                                        N91530-35-0009                      ASME SA105
: b. Bar Sco      and Forgings S~rt      Rods Mottle                                          N95969-32-0009                      ASME SA182      Cr.F316 Gisc  Insert Spring uashcrs      K60807-82-001          3 N91531-40-0030 N91521-40-0026 Adjuct eng 6ol I                                N91532-38-0015                      ASHE SA193 Gr ~ B6 spvesI e  'p 1  t  K60806-39-0018            N91 527-39-'0020                    AS)iE SA193 Gr ~ B6


PSL-2,NIS-2TRACKINGNO.SL-2-9-FORIINIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinservlceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:PRM9S-ZS8'5APPLiCABLEMANUFACTURE'SDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned/''wnrorOwner'sDesignee,TitleDate~(.,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcyclef/8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionscaLdNationalBoard,State,ProvidenceandEndorsements
i
                                                                    ~ ~
IFV>
P:Ice                  /5  7-Serial Ko.                          Katerial Specification Identif ication                        including Type or Grade sprf"g K60807-82-0013                      NX3108-0018
: d. Bolting Disc Holder K77785-31-0001 N91524-40-0020                                        ASME SB637 UNS N07718 Disc Bushin          K777S5-31-0001 N91525-38-0020                              Stellite      No. 6B Bonnet Stud                                  N93669                              ASME      1  3    r    7 ue certify that  the statanenta    made  in this report are correct.
Oate:                       19~~      Signed    Cros    Valve 4 Ga    e Co. By Kanufacturer Certificate of Authorization      Ko. 1878        exp      Se tember 30 ~        1 995 CERTlF lCATE OF SROP lKSPECTLOK l, the undersigned, holding a valid comsission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of              Pass.                 and eeployed by Arkuri ht-Boston Nanufacturers Kutual insurance C                                            have inspected the equipaent described in this Oata Report on                              c      19~> and state that to the best of ey knouledge and belief, the Karafacturer has constructed this equip.
aent in accordance uith the appL!cable Subsections of ASKE Section              Ill.
By signed this certificate, neither the inspector nor his employer Wakes any uarranty, ex-pressed or is@lied, concerning the equipnent described in this Oata Report. furthermore, neitherj the inspector nor his eaployer shall be Liable in any aarncr for any personal injury or property t daaage or a loss of any kind arising frora or corrected uith this inspection.
Oate      /                      19  r                    Factory Kvtual Systea
                                                  'oacai ss ions        r'         .       ~I l~
( inspector )                              (Rational Board, State, province      and Ko.)


PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsofthcASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501.SouthHwy.AIAJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V25003.WorkPerformedBy;'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:Chemical8VolumeControlDate:11/29/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:2305WO&#xb9;:95000522CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESectIII1989Edition/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialangeut5/8x11unc28angeut5/8x11unc28angetu5/8x11unc2Aangeu5/8x11unc2ANameofManufacturerawleutotawovaaineManufacturerSerialorHeatNo.eaoL63812eao8099572NationalBoardNo.OtherIdentificationGr2H94GR7"'ESKi05Gr87Gr87YearBuiltReplacedRepairedOI'eplacementepaceepacementepaceRepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedflangeboltingduetocorrosion.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-24-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:fYlMO,Q-X3lQ,APPLiCABLEMANUFACTURE'SDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignednerorner'sDesignee,TitleDele~~4~)ebee19~7CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection..)Commissionsinspector'sSignatureNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:3V25514.(a)IdentificationofSystem:Chemical&VolumeControlDate:11/29/95Sheet:1of3Unit:2P.O.&#xb9;:NAPCM&#xb9;:009-293MPWO&#xb9;:4092WO&#xb9;:95012783CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESectIII1986Ed/NoAdd.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialavessemy2'lobeavessemy2GlobeIpe2Sch80Ipe2Sch802000SocketWeld2SocketWeldNameofManufacturerarwaynoraingawiogaipeKobeSteeleraveer95-3574eraveer95-3573ManufacturerSerialorHeatNo.enaoSN-E-T516-74eatoV40407021NationalBoardNo.OtherIdentificationGRF316GRF316316TP304ESA376TP304ierER308ierER308YearBuilt993ReplacedRepairedorReplacementepaceRepacementepaceepacementepacementepacementASMECodeStamped(YorN)7.DescriptionofWork:REPLACE2"CHECKASPARTOFVALVEUPGRADE.EXISTINGWELDSREPLACED.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3~psigTestTemp.'F  
PSL-g, NIS-2 TRACKING NO.               SL-2                                                 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: l. Owner:                           Florida Power & Light Co.                 Date:       11/28/95 P.O. Box 529100                            Sheet:      1 of Miami, FL 33152 Unit:       2
: 2. Plant:                              St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM&#xb9;: NA 3    Work Performed        By'lorida Power & Light Co.                          PWO&#xb9;: 3606 6501 South Hwy. A1A WO &#xb9;:         95002732 01 Jensen Beach, FL 34957 CWO    &#xb9;: NA          Process Sheet: N/A
: 4. (a) Identification      of System:     Reactor Coolant Type Code Symbol Stamp    N/A Authorization No.         N/A (b) Component                        V1202 Identification:                                                                           Expiration Date          N/A (Mark Number)
(c) Code Class:         1 a) Applicable Construction Code and Addenda:                 ASME Sect III 1974 Edition / No Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of                  Name of          Manufacturer      National      Other          Year      Replaced      ASME Component              Manufacturer        Serial or Heat    Board                          Built    Repaired      Code No.        No. Identification                      or      Stamped OI'aterial Replacement (Yor N) isc nse                ros y  ave            eria  o                                                  ep ace N 91526424022                    Gr 651 isc      sert        rosy  a  e          ea    o                            6 7    1 92      ep acement N 95970-344015 ozz e                ros y ave            ena    o                A        45                      ep ace N91 523-374014                  GR 651 ozz e                ros y ave            ena    o                  A            62              ep acement N 95969-324006                    F316
: 7. Description of Work:          Replaced disc insert and nozzle.
(Valve S/N N59336-00-0005)
                                        **(Approved per PCM 41,7-291M )
: 8. Tests Conducted:             Hydrostatic                Pneumatic              Nominal Operating Pressure (ISLT)
Other: VT1              VT2          VT3                     psig    Test Temp.             'F


PSL-2,NIS-2TRACKINGNO.SL-24-FORMNIS-2(Back)Sheet2of39.Remarks:AsatisfactoryhydrostatictestwasperformedandwitnessedbyaVT-2certifiedinspector10.InspectionReportNumbers:D5~W~>O<P@~4QIXBAPPLICABLEMANuFACTURFSDATAREPORTSToBEATTACHEDCertificatofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignednerorner'sDesignee,TitleCate~gigV.Ig~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdesoibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectolsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate6.19~<
PSL-2,'IS-2 TRACKING NO.               SL-2                                                  FORM NIS-2 (Back)                                     Sheet 2 of      2
: 9. Remarks:         A satisfactory inser vice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:       + +qg 3,9&~
APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                        +   Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                                          ~Pe        LS l Date ne or  wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                    National Board, State, Providence and Endorsernents Date


PSL-I,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OiVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIPLSUPPLEMENTALSHEET1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LuciePlant6501SouthHwy.A1AJensenBeach,FL34957Date:4j22Jg4P.O.&#xb9;:NASheet:3of3Unit&#xb9;:23.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1APCM&#xb9;:009-293M6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentSocketWeldNameofManufacturereraveer95-3572ManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationierYearBuiltReplacedRepairedorReplacementepacemenASMECodeStampedPorN)
PSL-2, NIS-2 TRACKING NO.               SL-2                                             FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
FORMNPV-1CERT1FICATEHOLDERS'ATAREPORTFORNUCLEARPUMPSORVALVESAsRequiredbytheProvisionsoftheASMECade.Sectionill.Division1Pg.ofI.ManufacturedandcertifiedbyAnchor/DarlingVa1veCo.,701FirstStreet,Wi11iamsport,PA17(namesndsddtessotNCenificsteHoidetlMfdf,FloridaPoiverizLiqhtCo.,P.0.Bo'x029950,Miami,FL33102-9950(namesnaaadressotPurcnsserorawnerl3.,,..,St.LuciePlants,6501SouthA1A,JensenBeach,FL34957Inamesnaaaatessl4.ModelNo..SeriesNo.,orTypeGborawingW93239Rev.cRNN/A5.ASMECode.Sectionill,DivisionI:ValveB.Pumporvalve7.Material:Body1986(edioonlNominalinletsizeBonnetIeadenaaaatel(cfassrOutletsize(In.l(in.l-66-(CodeCaseno.lNAlalCert.Holder'sSerialNo.E-T516--4ib)Nat'IBoardNo.lc)BodySerialNo.ld)BonnetSerialNo.IelDiskSerialNo.MT.&#xb9;34735'uooiementa(informahoninformoflists.sketches.ordrawingsmsvbeusedoroinasd(llsizeis8yix11.I2)infonnaooninitemsIthrough4onthisasiaReootttsinciuaaaonescnshear.(3)eachsneetisnumoereasndthenumberOfSheetsisrecoraadstthetopatthisform.(12/86IThisform(6000371msvbeobtainedtramtheatderaeot..ASME.22tawarive.8ox2300.Fsirfield.NJ07007-2300.
: l. Owner:                       Florida Power & Light Co.                 Date:   11/28/95 P.O. Box 529100                            Sheet:      I of Miami, FL 33152 Unit:      2
PSL-1,NIS-2TRACKINGNO.SL-2-8-97FORMNIS-2OWIAVERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:02/01/96Sheet:1'f2Unit:2P.O.&#xb9;:N/APCM&#xb9;:N/ANPWO&#xb9;:8218WO&#xb9;:95032001-1AWCDN/A4.(a)IdentificationofSystemCCW(b)ComponentIdentificationSUPPORTCW-3002-152(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:N/A(SUPPORTFORCLASS3SYSTEM)5.(a)ApplicableConstructionCodeandAddenda:ANSIB31.11977ED.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1973EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeat'No.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)'ANGLE-A365"X5"X3/8"ANGLE-A365"X5"X3/8"ANGLE-A363"X3"X1/4"ANGLE-A363"X3"X1/4"N/AHUBINC.N/AINTERSTATESTEELNIAHEAT&#xb9;89180NIAF7116NIAN/ANIAN/AUTC381833RIR4R4590N/AUTC379177RIR4R-2876NIA1985NIA1983REPLACEDREPLACEMENTREPLACEDREPLACEMENTNONO7.DESCRIPTIONOFWORK:VALVEI-TCV-144B,VALVEEXTENSIONSTEMWASMISALIGNEDTOVALVEDUETOANORIGINALINSTALLATIONPROBLEM.THEENTIRESUPPORTNEEDEDTOBEMOVEDTOALLOWVALVESTEMREALIGNMENT.8..TestConducted:Hydrostatic[]Other:VT1[]VT2[]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)[]PSIGTestTemp.FHoldTime PSL-1,NIS-2TRACKINGNO.SL-2-8-97FORMNIS-2(Back)Sheet2of9.RemarksFINALINSPECTIONWASSUCCESFULLYPERFORMEDBYAVT3CERTIFIEDQ.C.ISNPECTOR.10.InspectionReportNumbers:MM96-161APPLICABLEMANUFACTURERSDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[X]Repair[]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/ASignedOwnersorOwI'sDBRee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate PSL-1,NIS-2TRACKINGNO.SL-2-8-98FORMNIS-2OWNWERSREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner2.Plant3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/11/95Sheet:1of2Unit:2P.O.f/:N/APCMf/:190-295NPWOf/:9105WOff:95033072-01WCDf/02714.(a)IdentificationofSystemBOILERFEEDWATER(b)ComponentIdentificationSUPPORTBF-4007-7008(MarkNumber)TypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(c)CodeClass:N/A(SUPPORT)5.(a)ApplicableConstructionCodeandAddenda:ASME1974S1974ADD.CodeCase:(b)ApplicableEditionofSectionXIforRepairsandReplacementComponents:1989EditionN/A6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedASMECodeRepairedorStampedReplacement(YorN)CAPSCREW3/4"-10UNC2AX21/2"NUT,HEAVYHEX3/4"-10UNC2BALLIEDNUTANDBOLTCO.ALLIEDNUTANDBOLTCO.B02156B47139N/AN/AA325UTC378011RIR3AD4723A194GR.2HUTC377944RIR3AH-214119911993REPLACEMENTREPLACEMENTNO7.DESCRIPTIONOFWORK:GAPPING,LOOSEBOLTINGANDSIGNSOFRUBBINGWEREIDENTIFIEDDURINGANENGINEERINGWALKDOWN.PCM190-295WASGENERATEDTOREPLACETHEBOLTINGWITHALARGERDIAMETER,HIGHERSTRENGTHBOLTING.8.TestConducted:Hydrostatic[]Other:VT1[]VT2[]Pneumatic[]VT3[X]NominalOperatingPressure(ISLT)[]PSIGTestTemp.oFHoldTime PSL-1,NIS-2TRACKINGNO.SL-2-8-98FORMNIS-2(Back)Sheet2of9.RemarksFINALINSPECTIONWASSUCCESFULLYPERFORMEDBYAVT3CERTIFIEDQ.C.ISNPECTOR.10.InspectionReportNumbers:M95450APPUCABLEMANUFACTURERSDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthis[]Repair[X]ReplacementconformstotherulesoftheAsmeCode,SectionXI.TypeCodeSymbolStamp:N/ACertificateofAuthorizationNoN/AOwnersorOwneDesiBe,TitleDateI~I[~,19~SCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyArkwrightMutualInsuranceCompanyhaveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon5/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandtakencorrectivemeasuresdescribeinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI,1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescribedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspectorsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate19/d PSL-S,NIS-2TRACKINGNO.SL-2-S-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:12/2/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4413WO&#xb9;:9501703CWO&#xb9;:NAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V25554.(a)IdentificationofSystem:Chemical8VolumeControlTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(a)ApplicableConstructionCodeandAddenda:ASMESEC.III,1977ED.,77ADDEN.CodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.eatoHT306778NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedol'eplacementepacementASMECodeStamped(YorN)7.DescriptionofWork:REPLACEPLUG/STEMASSEMBLYDUETOSEATLEAKAGE.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3.psigTestTemp.'F  
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                        P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM &#xb9;: 191-295M 1
: 3. Work Performed By.               Florida Power & Light Co.                 PWO&#xb9;: 4301 6501 South Hwy. A1A WO &#xb9;:     95015833 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:      N/A
: 4. (a) Identification    of System:      Reactor Coolant Type Code Symbol Stamp          N/A V1201 Authorization No.             N/A (b) Component Identification:                                                                       Expiration Date                N/A (Mark Number)
(c) Code Class:      1 a) Applicable Construction Code and Addenda:             ASME Sect III 1974 Edition / No Add        Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification    of Components    Repaired or Replaced and Replacement Components:
Type of              Name of          Manufacturer    National        Other          Year      Replaced            ASME Component          Manufacturer        Serial or Heat  Board                          Built    Repaired            Code or                                        No.         No. Identification                                    Stamped oi'eplacement Material (Y or N) pnng      as er          ros y                                    pnng          8                 ep ace Assembly                Valve                                      Washer ASME SA1 05 pnng      as er          ros y              ena  o                p ng        689                ep acement Assembly                Valve          K60807-834015                Washer ASME SA1 05
: 7. Description of Work:         SPRING 8 WASHER ASSEMBLY REPLACED BY WYLE DURING OVER HAUL.
(VALVES/N: N59336-00-0004)
: 8. Tests Conducted:         Hydrostatic Other:- VT 1           VT 2 Pneumatic VT 3       psigNominal Operating Pressure (ISLT)
Test Temp.                   'F


PSL-2,NIS-2TRACKINGNO.SL-2-8-099FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:6AMCI6-RO'C'~APPLICABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned(erownei'sDesignee,TitleDate~I,19)SCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate PSL-2,NIS-2TRACKINGNO.SL-2-0-~100FgFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbythcProvisionsofthcASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100MiamiFL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V32113.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:SafetyInjectionDate:12/8/95Sheet:1ofUnit:2P.O.&#xb9;:N/APCM&#xb9;:N/APWO&#xb9;:3624WO&#xb9;:94025081CWO&#xb9;:N/AProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESEC.III;1974EDITIONCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterial3/4"-10UNC2AALLTHREAD3/4-10UNC28NUTSNameofManufacturerALLIEDALLIEDManufacturerSerialorHeatNo.HEAT&#xb9;;88147-GPHEAT&#xb9;:604277NationalBoardNo.NANAOtherIdentificationSA193;GRADE87SA194,GRADE2HYearBuiltReplacedRepairedorReplacementReplacementReplacementASMECodeStamped(YorN)N7.DescriptionofWork:REPLACEINLETFLANGEBOLTS(2EA.)DAMAGEDDURINGREMOVALOFVALVE.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)XOther:VT1VT2XVT3~psigTestTemp.'F
PSL-2, NIS-2 TRACKING NO.                 SL-2rtt-FORIN NIS-2 (Back)                                         Sheet 2 of    2
: 9. Remarks:         A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:         rArtigr0 Ct        IIOC APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                              +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ne    Owner's Designee, Title Date    o"  >8,19          ~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board          of Boiler and Pressure Vessel Inspectors  and the  State  or Providence    of Florida  and employed  by Factory  Mutual  Engrg Assoc.
have inspected    the  components    described  in this Owner's Report during  operating  cycle  If8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectoi's Signature                                        National Board, State, Providence and Endorsements Date                                I 199a


PSL-2,NIS-2TRACKINGNO.SL-2-8-100FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:Ni~(60[35APPUCABLEMANUFACTURESOATAREPORTSToSEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedY44SRPvmerOvmer'sDesignee,TitleDate~19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Insectoi'ssignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate,199.(
PSL-1, NIS-2 TRACKING NO.             SL-2                                             FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP                        As Required by the Provisions of the ASME Code Section XI
PSL-1,NIS-2TRACKINGNO.SL-2-8-FPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL349573.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957Date:12/6/95Sheet:Iof3Unit:P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:4287WO&#xb9;:CWO&#xb9;:950160291A9501602901NAProcessSheet:N/A4.(a)IdentificationofSystem:MainSteamTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A(b)ComponentV8201(S/N59335-00-0001)Identification:V8207(S/N59335-00-0007)(MarkNumber)V8208(S/N59335-00-0008)(c)CodeClass:2V8211(S/N59335-00-0011)V8213(S/N59335-00-0013))ApplicableConstructionCodeandAddenda:ASMESectlil1974Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponentsTypeofComponentorMaterialIscnsert(V8211)iscnsert(V8211)>scnsert(V8201)iscnsert(V8201)pmessy(V8201)NameofManufacturerrosyaerosyaerosyaverosyaverosyaveManufacturerSerialorHeatNo.enaoN91608-334026aenaaaN91608-344027enaoN91608-31-0014enaoN91608-34-0030enaoK57208484126NationalBoardNo.NAOtherIdentification4Gr651458Gr651$TA4S8Gr6518Gr65193Gr86YearBuilt99992ReplacedRepairedorReplacementepaceepacementepaceepacementepaceASMECodeStamped(YorN)pinessy(V8201)rosyaveenaoK57208<94119Gr86931995epacement7.DescriptionofWork:Replaceddiscinsertsandspindleassembliesonlistedvalves.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2~VT3psigTestTemp.'F 0
: l. Owner:                       Florida Power  & Light Co.               Date:     11/30/95 P.O. Box 529100                          Sheet:      1  of 2 Miami, FL 33152 Unit:
PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of39.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:APPLICABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedI8uP'SiLPLliSdPVIS1erorer'sDesignee,TitleCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspectoi'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate
: 2. Plant:                         St. Lucie Nuclear Plant 6501 South Hwy. A I A                      P.O.&#xb9;:     NA Jensen Beach, FL 34957                    PCM    &#xb9;: 158-295M
: 3. Work Performed By:              Florida Power & Light Co.                PWO&#xb9;: 3614 6501 South Hwy. A1A WO &#xb9;:       95002185 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:       N/A
: 4. (a) Identification  of System:     Containment Spray Type Code Symbol Stamp          N/A Authorization No.               N/A (b) Component                      FCV-07-1 B Expiration Date                N/A Identification:
(Mark Number)
(c) Code Class:     2 ASME Sect III 1974 Ed/No Add            Code Case: None
    ) Applicable Construction Code and Addenda:
(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced      and Replacement Components:
Type of              Name of          Manufacturer      National      Other          Year      Replaced            ASME Component          Manufacturer        Serial or Heat    Board                        Built    Repaired            Code Of                                      No.         No. Identification                                  Stamped OI'eplacement Material (Y or N) a ve  ate                a ves                                            4                    ep ace Gr 316 a ve  ate        ooper n ustnes          eat o                          2          994      ep acement P-11534                      Gr 316
: 7. Description of Work:       Replaced valve gate due to wear.
: 8. Tests Conducted:         Hydrostatic              Pneumatic                Nominal Operating Pressure (ISLT)
Other: VT1            VT2          VT3                      psig    Test Temp.                   'F


PSL-1,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OiVNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIFPLSUPPLEMENTALSHEET1.Owner:FloridaPower&LightCo.P.O.Box529100Miami,FL33152Date:12/6/95Sheet:3of32.Plant:St.LuciePlant6501SouthHwy.A1AJensenBeach,FL34957Unit&#xb9;:P.O.&#xb9;:NA3.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1APCM&#xb9;:NA,6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:NameofComponentiscnse(V8208)iscnse(V8208)pinessy(V8208)pinessy(V8208)iscnse(V8207)iscnse(V8207)pinessy(V8207)pinessy(V8207)iscnse(V8213)iscnse(V8213)pinessy(V8213)pinessy(V8213)NameofManufacturerrosyaverosyaverosyaverosyaverosyaverosyaverosyaverosyaverosyaverosyaverosyaverosyaveManufacturerSerialorHeatNo.enaoN91608-31-0012enaoN91608-34-0031enaoK57208-33-0419enaoK5720849-0117enaoN91608-31-0011enaoN91608-34-0029enaoK57208-38-0148enaoK57208<9-0121enaoN91608-31-0006enaoN91608-34-0028enaoK57208-38-0140enaoK5720849-0111NationalBoardNo.OtherIdentificationGr651Gr651GrB6GrB6Gr651Gr651GrB6GrB6Gr651Gr651GrB6GrB6YearBuiltReplacedRepairedorReplacementepaceepacemenepaceepacemenepaceepacemenepaceepacemenepaceepacemenepaceepacemenASMECodeStamped(YorN)
PSL-2, NIS-2 TRACKING NO.                 SL-2                                                   FORM NIS-2 (Back)                                        Sheet 2 of    2
: 9. Remarks:        A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
: 10. Inspection Report Numbers:        I'I/I MQ Q    -Q+ 7+
APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section XI.
Repair
                                                                                                            +  Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                        M Acznk.Su/        Y'&(                    Cate ILINIS>
Own      r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board        of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by        Factory  Mutual  Engrg Assoc.
have inspected the components described in this        Owner's  Report  during  operating  cycle  &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions Inspectoi's Signature                                      National Board, State, Providence and Endorsements Date                                19  9a


CROSBYVAlVK6)BABKCO8PANYWIIENTHAM~MASSQ.C.AQUAFORMN-2NORNPTCERTIFICATEHOLDERS'ATAREPORTFORIDENTICALNUCLEARPARTSANDAPPURTENANCESAsRequiredbytheProvisionsoftheASMECode,SectionIII,Division1NottoExceedOneDay'aProducdonPg~of~~ManufacturedandoertIIIedbyCrosbValve8(GaeCo.43KendrickSt.WrenthamMA023(nameandaddresaofcertilicateholder).Man+actredforFloridaPower8LihtCP.O.Box029950HamiL02(nameandaddresaofpllrchaser)St.LuciePlantPSL-9726501SouthA1AJensenBeachFL34957(nameandaddress)(dra))vinylna}ASMECode,SeeuonIII1974(edNon)(fMflspecno.)(tenaceatrength}(CRH)NO2(addenda)(class)FabricatedlnacoordancewithConst.Spec.(Dlv.2only)(Ho.}'i.Remarks:DateIRj=-37'-2.tenn.nrtekneeegn.)-kttn.dec)gothteknenegn.)-t))hID(rkhkk)lengthoverall(Lhkk).Whanapplcable,CertificateHolders'atareportsareattachedforeachItemofthisreportNationalBoardNo.InNumericalOrderNatfc)nalBoardHo.InNumericalOrderN91608-34-0028(2)N91608-34-0029(3)N91608-34-0030(4)N91608-34-0031(12)(13)(I4)(6)(16)(8)(9)10)(18)(19)(2o)p.DesignpressurepsiTemp.'FHydro.testpressureattemp.F.(whenapplicable)
PSL-2NIS-2 TRACKING NO.              SL-2<-        ~107 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
CROSBF4-=c~cc~Ms~$Wd.-gQ.C.-392SHEE71OF2FORMN-2,NORNPTCERTIFICATEHOLDERS'ATAREPORTFORIDENTICALNUCLEARPARTSANDAPPURTENANCESAsRequiredbytheProvisionsoftheASMECode,SectionIII,DivisionI-NottoExceedOneDay'sProduction1.Manufacturedandcertifiedby(NameandAddressofNCert(f(cateHolder)2.Manufacturedfor3.LocationofInstallationFLORIDAPOWER&LIGHTCO.(NameandAddressofPurchaserorOwner)ST.LUCIE4,(CRN)5.ASTIVIA458GR,651(MaterialSpecNo.)(DrawingNo.)REIVIARS(TensileStrength)(NameandAddress)DS-C-59335REV.C1995(YearBuilt)6.Dia.ID7.Nom.Thickness(in.)LengthOverallInchMln.DesignThicknessDFInchDesignPressure(PSI)HydrostaticTest(psig)at(Whenapplicable)8.FabricatedinaccordancewithConst.Spec.(Div.2only)-(No.)TemperatureoFRevision-Date9.ASMECode,SectionIII,Division1:1974(Edition)10.RemarksTENSILEMIN:95000NO(AddendaDate)(Class)(CodeCaseNo.)11.Whenapplicable;CertificateHolders'atareportsareattachedforeachitemofthisreport:PartorAppurtenanceSerialNumberNationalBoardNo.NumericalOrderPartorAppurtenance>>NationalSerialNumberBoardNo.NumericalOrder(1)N91608-34-0027(2)(3)(4)(6)l6)(7)(8)(9)(10)(11)(12)(13)(14)('l5)(16)(17)(18)(19)(20)  
: 1. Owner:                      Florida Power  4 Light Co.             Date:      1/4/S6 P.O. Box 529100                          Slieet'      of Miami, FL 33152 Unit:      2
: 2. Plant:                          St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:    NA JensenBeach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:            Florida Power 4, Light Co.               PWO&#xb9;: 5913 6501 South Hwy. A1A WO &#xb9;:      95035159 Jensen Beach, FL 34957 CWO    &#xb9;: NA        Process Sheet:  N/A
: 4. (a) IdentiTication  of System:      Safety Injection Type Code Symbol Stamp    N/A HCV-3617 Authorization No.         N/A (b) Component                                                                                                  N/A Identification:                                                                      Expiration Date (Mark Number)
(c) 'Code Class:        2
    ) Applicable Construction Code and Addenda:        ASME SEC.III,  '1  ED.; W. '3  ADD.'ode Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other          Year    Replaced      ASME Component        Manufacturer        Serial or Heat  Board                        Built    Repaired        Code or                                      No.         No. Identification                    or        Stamped Material                                                                                    Replacement (Yor N)
SEAL WELD                FPL            Sl-VALV-2007                SAQ79 TQ16          NA    Replacement Weld
: 7. Description of Work:      REMOVE/REINSTALLSEAL WELD TO FACILITATEVALVEWORK.
: 8. Tests Conducted:      Hydrostatic Other:  VTI Pneumatic VT2 X        VT3              ~petg        TeetTemp.    ~'F Nominal Operating Pressure (ISLT)     X


ManufacturerSerialNo.N91608-34-0027Q.C.-392SHEE72OF2CERTIFICATEOFSHOPCOMPLIANCEWecertifythatthestatementsmadeinthisreportarecorrectandthatthis(these)conformtotherulesofconstructionoftheASMECade.SectionIII.Date2SSigned(NptCertificateHolder)(AuthorizedReprsentative)Expires~~~~(Date)CERTIFICATEOFDESIGNDesignspecificationcertifiedby"PEStateRegNo.DesignReportCertifiedby'EStateRegNo.'Signaturenotrequired-listnameonly.CERTIFICATEOFSHOPINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBailerandPressureVesselofhaveinspectedtheseitemsdescribedinthisDataReportonhasfabricatedthesepartsarappurtenancesinaccordancewiththeASMECode,SectionIII.Eachpartlistedhasbeenauthorizedforstampingonthedateshownabove.Bysigningthiscertificate,neithertheinspectornorhisemployermakesanywarrant,expressedorimplied,concerningthecomponentdescribedinthisDataReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromarconnectedwiththisinspection.Date1B1>.Signed(Inspector)<<FactoryMutualSystemsCommissions(Nat'I.Bd.,State,Prov.andNo.)  
PSL-2, NIS-2 TRACKING NO.                   SL-2        ~107 FORM NIS-2 (Back)                                         Sheet 2 of 2
/ROSRr~a<73Ol>P3agIoQ.C.-392SHEETIOF2-2,NORNPTCERTIFICATEIIOLMRS'ATAREPORTFORIDENTICAI.NUCLZARPARTSANDAPPURTENANCESAsRequirsdbytireProvisionsofdrsAS<YECods,SccnonIII,DivisionI-NottoErossdOneDay'sProduction1.Manufacturedsindcertifiedby(NameandAddressofNCertificateHolder)a.(CRNI6.ASMESA193GR.B6{MaterialSpecNo.)1995(YearBuilt)110000(TensileStrength)2.ManufacturedforFLORlDAPOWER5LIGHTCOMPANYJENSENBEACHFL(NameandAddressofPurchaserorOwner)3.Locat(onofinstallationLUC(ESTORESJESENBEACHL(NameandAddress)DS-C-69335REV.C(DrawingNa.)6.Dia.ID7.Nom.Thickness((n.)LengthOverallinchMin.DesignThicknessinchDesignPressure(PSI)TemperatureHydrostaticTest(psig)atoF{Whenapplicable)8.FabricatedinaccordancewithConst.Spec.{Div.2only)--Revision-Date(No.)9.ASMECode,Sectionill,Division1:1974(Edit(an)'l0.RemarksNOADDENDA(AddendaDate)(Class){CodeCaseNo.l1'l.Whenapp{(cab(e,Certif(cateHolders'atareportsareattachedforeachitemofthisreport:PartarAppurtenanceSerialNumberNet(analBoardNo.NumericalOrderPartorAppurtenanceSerialNumberNationalBoardNo.NumericalOrderK6720&%9%111(2)K57208%9-0117(3)K67208%9%119(a)K67208&9%121(5)(8)(7)(8)(9)(10){11)(12)(13)(1a)('l6)(16)('l7){18)(19)(20)
: 9. Remarks:         A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
ManufacturerSerialNo.K5720&%9-0111Q.C.-992SHEET,2OF2iR$1~&0%+bCR4~~mrrevaa~~~s'aa'n~~CERTIFICATEOFSHOPCOMPLIANCEWecertifythatthestatementsmadeinthisreportarecorrectandthatthis(these)&PINO"E4&SEMBIESconformtotherulesofconstructionoftheASMECode,SectionIII.l"ao3377(Vog(gDateSigned(NptCertificateHolder)(AuthorizedReesentative)Expires~E~(Date)CERTIFICATEOFDESIGNDesignspeclficatloncertifiedby'EStateRegNo.DesignReportCertlfiedby>>PEStateRegNo.<<Signaturenotrequired-listnameonly.CERTIFICATEOFSHOPINSPECTIONI,theundersigned.holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselofhaveinspectedtheseitemsdescribedlnthisDataReporton19~5andstatethattothebestofmyknowledgeandbelief.theCertificateHolderhasfabricatedthesepartsorappurtenancesinaccordancewiththeASMECode,SectionIII.Eachpartlistedhasbeenauthorizedfor'stampingonthedateshownabove.Bysigningthiscertificate,neithertheinspectornorhisemployermakesanywarrant,expressedorimplied,concerningthecomponentdescribedlnthisDataReport.Furthermore,neithertheInspectornorhisemployershaltbeliablelnanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnectedwiththisinspection.Date195'Signed(Inspector)<<FactoryMutualSystemsCommissions(Nat'I.Bd..State,Prov.andNo.)
: 10. Inspection Report Numbers:              MM95-2614 APPUCABI.E MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this                        Repair  X Replacement conforms to the rules of the ASME Code, Section XI.
PSLQNIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNERISREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957Date:11/29/95Sheet:1of2Unit:P.O.&#xb9;:NAPCM&#xb9;:NA3WorkPerformedBy'loridaPower&LightCo.6501SouthHwy.AIAJensenBeach,FL34957PWO&#xb9;:WO&#xb9;:36049500273101(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1V12004.(a)IdentificationofSystem:ReactorCoolantCWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDate~N/A)ApplicableConstructionCodeandAddenda:ASMESectIII1974Edition/NoaddendaCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialeieave(CodeSafety)eieave(CodeSafety)NameofManufacturerrosyaverosyaveManufacturerSerialorHeatNo.enaoN59336-00-0003enaoN5933641-0002NationalBoardNo.30OtherIdentificationGrCF8MGlCF8MYearBuilt99ReplacedRepairedorReplacementepaceepacementASME.CodeStamped(YorN)7.DescriptionofWork:Replacedexisitingvalvewithnewspare.S/N59336-01-002(Newvalve)8.TestsConducted:HydrostaticOther:VT1PneumaticNominalOperatingPressure(ISLT)VT2VT3psigTestTemp.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed 0
(          ~     itiIIUTStePI/
or Owner's Designee, Title IS I              Date        t  f      19  ~~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the OwneVs Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                NB7719 FL Com          &#xb9;60 inspectoVs Signature                                      Natioriat Board, State, Providence and Endorsements Date


PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinsewiceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.inepeoiionReportNombem:lnNR5Qlip/pAPPLICABLEMANUFACTURE'SDATAREPORTSToBEATI'ACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/AsigneoSf'R.Puceolv'.I6Ineornei'sDesignee,TitleDateMCt/'-f,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.InspactolsSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate GROSBYYALVE8GAGEDCOMPALYWItKIITHAM~MASSIF9XXaPate~etI<>FORMMV-1FORSAFETYANGSAFEtYREI.IEFVALVESr<<quiredbytheprovisionsoftheAsMECodeRulesDATAREPORTSafetyandSafetyReliefValveSO.C..CCC~1'l.ManufacturedByerosvalveILcaeco.43rendrickstreetwrenthanKa02093Namearx$AddressModelMo.orderMo.N28017HB-BP-86ContractGateMaticnslaboardMo.2.ManufacturedFor=daoeNameandAddressOrderNo.FloridaPowerieLightCo.P.O.Box029950Miami,FL33102NameandAddrcs4.LocationofPlantSt.LucieStores-PSL-9726501SouthA1AJensenBeachFL349575.ValveIdcntificaticnSPARESerialNo.N59336-01-0002GravingNo.DS-C-59336-1Rev.TypeSafetOrificeSize1~531Safety,SafetyRelief,Pilot,PoverActuatedInch6.SctPressure(PSIG)2485InchInchInch0Desi~&#x17d;.700FFScaepedCapacity212182LBSHRSteama3XOverpresure-RatedT~ratureBiovdovn(Pslr)15XofSPKydroscacicTest(PSIC)Inlet3750Cpiecevalve7507.Thececeriai~design,constructionandvorkmanshipc~lyvithAWECode,SectionIII.Class1calcic1974,AddendaGateNo~CaseMo.a.CastingsSerialNo.identificationMaterialSpecificationincludingTypeorGradeK60802-36-0009BarnetN91530-35-0009ASMESA105b.BarScoandForgingsS~rtRodsMottleGiscInsertN95969-32-0009ASMESA182Cr.F316SpringuashcrsK60807-82-0013N91531-40-0030N91521-40-0026Adjucteng6olIN91532-38-0015spvesIe'p1tK60806-39-0018N91527-39-'0020ASHESA193Gr~B6AS)iESA193Gr~B6
PSL-2, NIS-2 TRACKING NO.             SL-2           ~1th r            e          FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner:                      Florida Power  & Light Co.             Date:       2/6/96 P.O. Box 529100                          Sheet:     1  of  2 Miami, FL 33152 Unit:      2
: 2. Plant:                         St. Lucie Nuclear Plant 6501 South Hwy. A1A                      P.O.&#xb9;:      NA Jensen Beach, FL 34957                    PCM&#xb9;: NA
: 3. Work Performed By:            Florida Power & Light Co.               PWO    &#xb9;:  5925 6501 South Hwy. A1A WO &#xb9;:      95035220 Jensen Beach, FL 34957 CWO &#xb9;: NA              Process Sheet:      N/A
: 4. (a) Identification of System:      Feedwater Type Code Symbol Stamp          N/A V0 9125                                          Authorization No.             N/A (b) Component Identification:                                                                      Expiration Date                N/A (Mark Number)
(c) Code Class:        2
    )  Applicable Construction Code and Addenda: ASME SEC. III; 1974 ED. -,75 ADDEDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
: 6. Identification  of Components Repaired or Replaced and Replacement Components:
Type of            Name of          Manufacturer    National      Other          Year    Replaced            ASME Component          Manufacturer        Serial or Heat  Board                        Built    Repaired            Code or                                      No.         No. Identification                                  Stamped oi'eplacement Material (Yor N)
ALLTHREAD        ALLIEDNUT & BOL                          NA        SA193 B7        1993    Replacement 3/4' 10 UNG-2A HEX NUTS        ALLIEDNUT & BOL        HT E04277        NA      SA194 GR 2H                Replacement 3/4-10 UNG 2B 1/Z HEX HEAD PLU            TIOGA            HT&#xb9; 085K        NA          SA 105                  Replacement
: 7. Description of Work:      REPLACE BOLTING AND VALVE PLUG WHICH WERE REMOVED DURING INSPECTION OF VALVE.
: 8. Tests Conducted:        Hydrostatic Other: VTI
                                                  ~     Pneumatic VT2 X        VT3 Nominal Operating Pressure (ISLT)
                                                                                    ~pstg          TestTemp.         ~'F    X


iIFV>~~/57-P:IceSerialKo.IdentificationKaterialSpecificationincludingTypeorGradesprf"gK60807-82-0013d.BoltingNX3108-0018DiscHolderK77785-31-0001N91524-40-0020DiscBushinK777S5-31-0001N91525-38-0020ASMESB637UNSN07718StelliteNo.6BBonnetStudN93669ASME13r7uecertifythatthestatanentamadeinthisreportarecorrect.Oate:19~~SignedCrosValve4GaeCo.ByKanufacturerCertificateofAuthorizationKo.1878expSetember30~1995CERTlFlCATEOFSROPlKSPECTLOKl,theundersigned,holdingavalidcomsissionissuedbytheNationalPressureVesselinspectorsandtheStateorProvinceofPass.Arkuriht-BostonNanufacturersKutualinsuranceCinspectedtheequipaentdescribedinthisOataReportonstatethattothebestofeyknouledgeandbelief,theKarafacturerhasaentinaccordanceuiththeappL!cableSubsectionsofASKESectionIll.BoardofBoilerandandeeployedbyhavec19~>andconstructedthisequip.Bysignedthiscertificate,neithertheinspectornorhisemployerWakesanyuarranty,ex-pressedoris@lied,concerningtheequipnentdescribedinthisOataReport.furthermore,neitherjtheinspectornorhiseaployershallbeLiableinanyaarncrforanypersonalinjuryorpropertytdaaageoralossofanykindarisingfroraorcorrecteduiththisinspection.Oate/19rFactoryKvtualSystea(inspector)'oacaissionsr'.~Il~(RationalBoard,State,provinceandKo.)
PSL-2, NIS-2 TRACKING NO.                 SL-2C-         ~110 f,
PSL-g,NIS-2TRACKINGNO.SL-2-2-FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1V12023WorkPerformedBy'loridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ReactorCoolantDate:11/28/95Sheet:1ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:3606WO&#xb9;:9500273201CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1974Edition/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOI'aterialiscnseiscsertozzeNameofManufacturerrosyaverosyaerosyaveManufacturerSerialorHeatNo.eriaoN91526424022eaoN95970-344015enaoN91523-374014NationalBoardNo.OtherIdentificationGr65167A45GR651YearBuilt192ReplacedRepairedorReplacementepaceepacementepaceASMECodeStamped(YorN)ozzerosyaveenaoN95969-324006AF31662epacement7.DescriptionofWork:Replaceddiscinsertandnozzle.(ValveS/NN59336-00-0005)**(ApprovedperPCM41,7-291M)8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F PSL-2,'IS-2TRACKINGNO.SL-2-8-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:++qg-3,9&~APPUCABLEMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedneorwner'sDesignee,Title~PeLSl"DateCERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspector'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsernentsDate PSL-2,NIS-2TRACKINGNO.SL-2-8-FORMNIS-2OWNERISREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:1V12013.WorkPerformedBy.FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:ReactorCoolantDate:11/28/95Sheet:IofUnit:2P.O.&#xb9;:NAPCM&#xb9;:191-295M1PWO&#xb9;:4301WO&#xb9;:95015833CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/Aa)ApplicableConstructionCodeandAddenda:ASMESectIII1974Edition/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialpnngaserAssemblypnngaserAssemblyNameofManufacturerrosyValverosyValveManufacturerSerialorHeatNo.enaoK60807-834015NationalBoardNo.OtherIdentificationpnng8WasherASMESA105png689WasherASMESA105YearBuiltReplacedRepairedoi'eplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:SPRING8WASHERASSEMBLYREPLACEDBYWYLEDURINGOVERHAUL.(VALVES/N:N59336-00-0004)8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:-VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2rtt-FORINNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:rArtigr0-CtIIOCAPPLICABLEMANUFACTURESDATAREPORTSTOBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedneOwner'sDesignee,TitleDateo">8,19~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycleIf8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspectoi'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate199aI PSL-1,NIS-2TRACKINGNO.SL-2-8-FPFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXIl.Owner:2.Plant:3.WorkPerformedBy:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.AIAJensenBeach,FL34957FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL34957Date:11/30/95Sheet:1of2Unit:P.O.&#xb9;:NAPCM&#xb9;:158-295MPWO&#xb9;:3614WO&#xb9;:95002185CWO&#xb9;:NAProcessSheet:N/A(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2FCV-07-1B4.(a)IdentificationofSystem:ContainmentSprayTypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESectIII1974Ed/NoAddCodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentOfMaterialaveateaveateNameofManufactureravesoopernustnesManufacturerSerialorHeatNo.eatoP-11534NationalBoardNo.OtherIdentification4Gr3162Gr316YearBuilt994ReplacedRepairedOI'eplacementepaceepacementASMECodeStamped(YorN)7.DescriptionofWork:Replacedvalvegateduetowear.8.TestsConducted:HydrostaticPneumaticNominalOperatingPressure(ISLT)Other:VT1VT2VT3psigTestTemp.'F PSL-2,NIS-2TRACKINGNO.SL-2-2-FORMNIS-2(Back)Sheet2of29.Remarks:AsatisfactoryinserviceleakagetestwasperformedandwitnessedbyaVT-2certifiedinspector.10.InspectionReportNumbers:I'I/IMQQ-Q+7+APPLICABLEMANUFACTURESDATAREPORTSTOBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.Repair+ReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASignedMAcznk.Su/Y'&(OwnrOwner'sDesignee,TitleCateILINIS>CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspectoi'sSignatureCommissionsNationalBoard,State,ProvidenceandEndorsementsDate199a PSL-2NIS-2TRACKINGNO.SL-2<-~107FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower4LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)'CodeClass:2HCV-36173.WorkPerformedBy:FloridaPower4,LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentiTicationofSystem:SafetyInjectionDate:1/4/S6Slieet'ofUnit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5913WO&#xb9;:95035159CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III,'1ED.;W.'3ADD.'odeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialNameofManufacturerManufacturerSerialorHeatNo.NationalBoardNo.OtherIdentificationYearBuiltReplacedRepairedorReplacementASMECodeStamped(YorN)SEALWELDFPLSl-VALV-2007SAQ79TQ16NAReplacementWeld7.DescriptionofWork:REMOVE/REINSTALLSEALWELDTOFACILITATEVALVEWORK.8.TestsConducted:Hydrostatic'PneumaticNominalOperatingPressure(ISLT)XOther:VTIVT2XVT3~petgTeetTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2-8-~107FORMNIS-2(Back)Sheet2of29.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:MM95-2614APPUCABI.EMANUFACTURESDATAREPORTSToBEATTACHEDCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/Asigned(~itiIIUTStePI/ISI0orOwner'sDesignee,TitleDatetf19~~CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwneVsReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.inspectoVsSignatureCommissionsNB7719FLCom&#xb9;60NatioriatBoard,State,ProvidenceandEndorsementsDate
FORM NIS-2 (Back)                                       Sheet 2 of 2
: 9. Remarks:         A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
: 10. Inspection Report Numbers:               MM95-2622 APPUCABLE MANUFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this                      Repair   X Replacement conforms to the rules of the ASME Code, Section XI.
Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed                            ~g    '3PV er's Designee, Title Date  i2jD (e        19  R6 tNner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.
have inspected the components described in this Owner's Report during operating cycle &#xb9;8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions              NB7719 FL Com          &#xb9;60 Inspectoi's Signature                                      National Board, State, Providence and Endorsements Date                                  19  W6


PSL-2,NIS-2TRACKINGNO.SL-2-8-~1threFORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTSAsRequiredbytheProvisionsoftheASMECodeSectionXI1.Owner:2.Plant:FloridaPower&LightCo.P.O.Box529100Miami,FL33152St.LucieNuclearPlant6501SouthHwy.A1AJensenBeach,FL34957(b)ComponentIdentification:(MarkNumber)(c)CodeClass:2V091253.WorkPerformedBy:FloridaPower&LightCo.6501SouthHwy.A1AJensenBeach,FL349574.(a)IdentificationofSystem:FeedwaterDate:2/6/96Sheet:1of2Unit:2P.O.&#xb9;:NAPCM&#xb9;:NAPWO&#xb9;:5925WO&#xb9;:95035220CWO&#xb9;:NAProcessSheet:N/ATypeCodeSymbolStampN/AAuthorizationNo.N/AExpirationDateN/A)ApplicableConstructionCodeandAddenda:ASMESEC.III;1974ED.-,75ADDEDACodeCase:None(b)ApplicableEditionofSectionXIUtilizedforRepairsandReplacementComponents:1989Edition.6.IdentificationofComponentsRepairedorReplacedandReplacementComponents:TypeofComponentorMaterialALLTHREAD3/4'10UNG-2ANameofManufacturerALLIEDNUT&BOLManufacturerSerialorHeatNo.NationalBoardNo.NAOtherIdentificationSA193B7YearBuilt1993ReplacedRepairedoi'eplacementReplacementASMECodeStamped(YorN)HEXNUTS3/4-10UNG2BALLIEDNUT&BOLHTE04277NASA194GR2HReplacement1/ZHEXHEADPLUTIOGAHT&#xb9;085KNASA105Replacement7.DescriptionofWork:REPLACEBOLTINGANDVALVEPLUGWHICHWEREREMOVEDDURINGINSPECTIONOFVALVE.8.TestsConducted:Hydrostatic~PneumaticNominalOperatingPressure(ISLT)XOther:VTIVT2XVT3~pstgTestTemp.~'F PSL-2,NIS-2TRACKINGNO.SL-2C-~110Sheet2of2f,FORMNIS-2(Back)9.Remarks:ASATISFACTORYINSPECTIONFORLEAKAGEWASPERFORMEDANDWITNESSEDBYAVT2CERTIFIEDINSPECTOR.10.InspectionReportNumbers:MM95-2622APPUCABLEMANUFACTURESOATAREPORTSToBEATTACHEOCertificateofComplianceWecertifythatthestatementsmadeinthereportarecorrectandthisconformstotherulesoftheASMECode,SectionXI.RepairXReplacementTypeCodeSymbolStamp:N/ACertificateofAuthorizationNo.:N/ASigned~g'3PVtNnerer'sDesignee,TitleDatei2jD(e19R6CERTIFICATEOFINSERVICEINSPECTIONI,theundersigned,holdingavalidcommissionissuedbytheNationalBoardofBoilerandPressureVesselInspectorsandtheStateorProvidenceofFloridaandemployedbyFactoryMutualEngrgAssoc.haveinspectedthecomponentsdescribedinthisOwner'sReportduringoperatingcycle&#xb9;8startingon05/94,andstatethattothebestofmyknowledgeandbelief,theOwnerhasperformedexaminationsandandtakencorrectivemeasuresdescribedinthisOwner'sReportinaccordancewiththerequirementsoftheASMECode,SectionXI.1989Edition,noaddenda.BysigningthiscertificateneithertheInspectornorhisemployermakesanywarranty,expressedorimplied,concerningtheexaminationsandcorrectivemeasuresdescibedintheOwner'sReport.Furthermore,neithertheInspectornorhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageorlossofanykindarisingfromorconnectedwiththisinspection.Inspectoi'sSignatureCommissionsNB7719FLCom&#xb9;60NationalBoard,State,ProvidenceandEndorsementsDate19W6 k  
k}}
}}

Latest revision as of 13:28, 4 February 2020

Form NIS-1 Owners Data Rept for Inservice Insps, for 960325
ML17228B461
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 03/25/1996
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17228B460 List:
References
NUDOCS 9604150125
Download: ML17228B461 (425)


Text

FORM NIS-1 OWNERS'ATA REPORT FOR INSERVICE INSPECTIONS March 25, 1996 Page 1 of 7

1. Owner: Florida Power and Light Company P.O. Box 529100 Miami, Florida 33152
2. Plant: St. Lucie Nuclear Power Plant 6501 South Highway AlA Jensen Beach, Florida 34957 3 ~ Plant Unit:~

4 ~ Owner Certificate of Authorization (if recpxired) 5 Commercial Service Date 6 ~ National Board Number for Unit:

7 ~ Components In'spected:

Component or Manufacturer Manufacturer State or Nat'l Appurtenance or Installer or Installer Serial Province Board No No. No.

Reactor Vessel Combustion 71172 N/A N/A En ineerin Pressurizer Combus tion 71372 N/A N/A En ineering Steam Generator 2A Combustion 71272-1 N/A N/A En ineerin Steam Generator 2B Combustion 71272-2 N/A N/A Engineerin Letdown Heat Exchanger Ebasco N/A N/A N/A Reactor Coolant Pum 2Bl Byron Jackson 741-N-003 N/A N/A Reactor Coolant Piping Ebasco I-42-RC-123 N/A N/A I-30-RC-121 I-12-RC-147 I-12-RC-154 I-10-RC-302 I-4-RC-101 I-4-RC-103 I-3-RC-309 I-3-RC-310 I-2-RC-122 I-2-RC-125 I-2-RC-149 l,

9'b04i50i25 9b040i 05000389 ',

PDR ADQCK 8 PDR

NIS-1 Report (continued) Page 2 of 7 i Owner:

Plant:

Florida Power and Light Company, P.O.

St. Lucie Nuclear Power Plant Box 529100, Miami, Florida 33152 6501 South Highway A1A, Jensen Beach, Florida 34957

3. Plant Unit:~
4. Owner Certificate of Authorization (if required) 5.
6. National Board Number for Unit:

Component or Manufacturer Manufacturer State or Nat,'

Appurtenance or Installer Serial or Installer Province Board No. No. No.

Safety Injection Piping Ebasco/FPL I-12-S I-151 N/A N/A I-10-SZ-127 I-10-SI-130 I-6-SZ-516 I-6-SI-518 I-6-SZ-113 I-3-SI-179 I-3-SI-191 I-2-SI-109 I-2-SI-215 Chemical and Volume FPL I-2-CH-104 N/A N/A Control Piping I-2-CH-145 I-2-CH-146 I-2-CH-347 Shutdown Cooling Heat Ebasco N/A N/A N/A Exchanger 2A Feedwater Piping FPL I-18-BF-51 N/A N/A I-18-BF-52

8. Examination Dates  : Fro 9 ~ Inspection Period Identification  : First Period
10. Inspection Interval Identification: Second Interval, from taalllkL-
11. Applicable Edition of Section XI ~39 Addenda ~ng
12. Date/Revision of Inspection Plan:
13. Abstract of examinations and test. Include a list of examinations and tests and a statement concerning status of work recplired for the inspection plan.

An Inservice Examination of selected Class 1, 2, and 3 components and piping systems of Florida Power and Light s St. Lucie Unit 2 Nuclear Power Plant was performed during the 1995 Refueling Outage. This outage began on October 9, 1995 and ended on

NIS-1 Report (continued) Page 3 of 7 1 ~ Owner: Florida Power and Light ComPany, P.O. Box 529100, Miami, Florida 33152

2. Plant: St ~ Lucia Nuclear Power Plant 6501 South Highway A1A, Jensen Beach, Florida 34957
3. Plant Unit:~

4~ Owner Certificate of Authorization (if required) 5.

6. National Board Number for Unit:

January 4, 1996. This was the second outage of the first period of the second ten year interval.

The components and piping systems examined were selected in accordance with the St. Lucie Second Ten Year Inservice Inspection Program, which was prepared in accordance with the requirements of the 1989 Edition of ASME Section XI.

Manual ultrasonic, radiographic, visual, magnetic particle, and liquid penetrant non-destructive techniques were used to examine components, piping, and their supports. The examinations were performed by FPL personnel, supported by examiners supplied by Raytheon Engineers and Constructors. A listing of examinations performed is attached to this summary.

Eddy Current examinations on Steam Generators A and B were conducted by FPL personnel from November 1, 1995 through November 9, 1995. A total of 16,355 tubes were examined. Five tubes were plugged in Steam Generator A and 11 tubes plugged in Steam Generator B during this outage. See the attached NIS-BB report for the summary of examination results.

Snubber functional testing and visual examinations were conducted in accordance with St. Lucie Plant Technical Specifications.

Examination and testing services were supplied by Wyle Laboratory, Inc. See the attached report for the summary of examination results.

System Pressure testing was conducted by the plant to applicable Plant Technical Specifications and Procedures.

The examinations performed for the first period meet or exceed the requirements of Program B of Section XI.

See the attached Examination Tables for a listing of examinations performed.

14. Abstract of Conditions Noted e cto es The Reactor Pressure Vessel studs, nuts, washers, threads in the flange, and welds were examined with visual, magnetic particle,

, 3.

4~

Owner:

Plant:

Plant Owner NIS-1 Report (continued)

Florida Power and Light Company, P.O.

St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~

Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)

Florida 33152 Page 4 of 7 5~ Camercial Service Date :

6. National Board Nwher for Unit:

and ultrasonic techniques. One acceptable linear indication was found on one nut. Acceptable corrosion and pitting was found on all washers. No reportable indications were found.

The flange to shell weld was examined with ultrasonic techniques.

No reportable indications were found.

See the NIS-BB report for Steam Generator eddy current. results.

Pressurizer nozzle to flange welds, nozzle to head welds, and inner radius sections were examined using penetrant and ultrasonic techniques. Acceptable slag inclusions were found in one nozzle to head weld. One safety valve flange bolt was found to have acceptable incomplete thread engagement. No reportable indications were found.

Reactor Coolant piping welds and bolting were examined using visual, magnetic particle, penetrant, and ultrasonic techniques.

No reportable indications were found.

Visual, surface, and ultrasonic examinations were performed on Safety Injection welds and component supports. Geometric indications were recorded. One spring support was found with settings outside tolerances. No reportable indications were found.

Valve bolting and internal surfaces were examined with visual techniques. No reportable indications were found.

~ ~

Visual, surface, and ultrasonic examinations were performed on shutdown cooling welds and component supports. Geometric indications were recorded. No reportable indications were found.

, 3.

4.

Owner:

Plant:

Plant Owner NIS-1 Report (continued)

Florida Power and Light ComPany, P.O.

St. Lucia Huclear Power Plant 6501 South Highway A1A, Jensen Unit:~

Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)

Florida 33152 Fage 5 of 7 5~

6. National Board Humber for Unit:

One spring support was found to have a loose lock nut and incomplete thread engagement. No reportable indications were found.

Valve internal surfaces were examined with visual techniques.

Valve V-3217 was found to have wear on the body and disk seat area. No reportable indications were found.

Visual and surface examinations were performed on pressurizer auxiliary spray welds and component supports. No reportable indications were found.

915UR+~I.

Visual, surface, and ultrasonic examinations were performed on Safety Injection welds, component supports, and integral attachments. Geometric indications were recorded. One acceptable round indication was recorded. No reportable indications were found.

t o o '

Magnetic particle and ultrasonic techniques were used to examine the shutdown cooling heat exchanger "A". No reportable indications were found.

Main Feedwater integral attachment welds were examined using magnetic particle techniques. No reportable indications were found.

Charging piping welds were examined using liquid penetrant techniques. No reportable indications were found.

I,3~

4~

5.

6.

Owner:

Plant:

Plant Owner NIS-1 Report (continued)

Florida Power and Light Company, P.O.

St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~

Certificate of Authorization Connercial Service Date :

National Board Number for Unit:

Beach, Box 529100, Hiami, Florida 34957 (if required)

Florida 33152 Page 6 of 7 Two inch valve V-2169, located in the charging system, was replaced during this outage. Baseline examinations were performed on the new piping welds.

15. Abstract of Corrective Measures Recommended and Taken The spring support found to have settings outside tolerances was reset. A follow-up visual examination confirmed no other recordable indications.

0 The loose lock nut and incomplete thread engagement on one spring support were tightened. A follow-up visual examination confirmed no other recordable indications.

Valve V-3217 was lapped to remove the wear areas noted. A new disk was also installed. A follow-up examination confirmed no other recordable indications.

, 3.

4.

Owner:

Plant:

Plant Owner NIS-1 Report (continued)

Florida Power and Light Company, P.O.

St. Lucie Nuclear Power Plant 6501 South Highway A1A, Jensen Unit:~

Certificate of Authorization Beach, Box 529100, Hiami, Florida 34957 (if required)

Florida 33152 Page 7 of 7 5.

6. National Board Number for Unit:

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No.

Expiration Date Date: Signed:

By CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of St. Lucie County, Florida, and employed by Arkwright Mutual Insurance Company of Norwood, Massachusetts, have inspected the components described in this Owner's Report during the period 10/9/95 to 1/4/96, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Data Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Insp ctor's Signature National Board, State, u/ s~~

Province, and Endorsements Date: ~ 5 4 7- 'P4

St. Lucie Unit

~

~

2 Docket No. 50-389 Fall 1995 Refueling Outage NIS-j. ATTACHMENT j.

EXAMINATION TABLES

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 1 REVI S ION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS H I 0 20NE NUHBER: 2-001 ASHE OHGT SEC. XI RSEH SUMHARY EXAHIHAT ION AREA CATGY EXAH E I 0 E REMARKS NUHBER IDENT IF I CAT IOH ITEM NO HETHOO PROCEDURE C G H R **CALIBRATIOHBLOCK**

REF. DUG. NO. 02-001-002000 '101-121 BA UT1.5 NDE 5.12-1 X--- 10/19/95 - UT complete, examination UPPER SHELL TO FLANGE MELO B1.30 UT 5.7 NDE 5.12-2 X--- performed from the flange surface, UT 12.5 NDE 5.12.3 X.-- examination from the shell side will be performed at a later time

    • UT-1, UT-8**

REF. DUG. No.02-001 c 006300 S-01A THRU S 54A B-G 1 HT HDE 2.2.31,32 X - - - 04/25/95 - HT, VT-1, and UT complete, RPV STUDS 1 THRU 54 86.30 HT NDE 2.2-35,36 X - - - examined group "A" studs thru 54 HT NDE 2.2-37 X - -- 1 VT.'I NDE 4.1.34,36 X - --

VT-1 HDE 4.1-38 X - - - >>>>7-1.125-8-CS-52-SLC>>>>

UT.45 NDE 5.7.13,14 X UT-80 HDE 5.7-15,16 X UT-45 NDE 5.7-17,18 X-UT-80 NDE 5.7-19 X---

UT-45 NDE 5.7-20,21 X---

UT-80 NDE 5.7-22 X---

UT-45 HDE 5.7-23,24 X---

006500 N-01A THRU N 54A B-G.1 HT HDE 2.2-31,33 - - - X 4/25/95 - MT and UT complete, examined RPV HUTS 1 THRU 54 86.30 HT HDE 2.2.34,38 - - - X group >>A" nuts 1 thru 54, one acceptable UT-45 NDE 5.10-1 X - - - linear indication UT-45 NDE 5.10-2 X - --

UT-45 NDE 5.10-3 X - - - **UT-51**

006700 W-OIA THRU M-54A B-G-1 VT-1 NDE 4.1-35 X - - - 4/25/95 - VT-'I complete, examined group RPV IIASHERS 1 THRU 54 86.50 VT-1 HDE 4.1-37 - - - X eA" washers 1 thru 54, acceptable VT-1 HDE 4.1-39 - - - X corrosion and pitting 006900 FL-01 THRU FL-54 B-G-1 UT 0 HDE 5.12-4 X . - - 10/19/95 - UT complete, examination THREADS IH RPV FLANGE 86.40 performed from the seal surface

    • UT 8**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 2 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COHPONENTS Generator 2A Primer Side N I 0 ZONE NUMBER: 2-003 ASHE ONGT SEC. XI RSEH SUHHARY EXAHINATION AREA CATGY EXAH E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G H R **CALIBRATIONBLOCK*"

REF. D'IJG. NO.02-003 015700 TUBE BUNDLE B-0 ECT NDE 1.3 - - - X 11/9/95 - 8,142 tubes examined, 236 U-TUBES B16.20 indications, five tube plugged this outage due to HRPC EZI indications

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 3 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS Generator 2B Primer Side N I 0 ZONE NUMBER: 2-004 ASME ONGT SEC. XI RSEN

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDEHTIFICATIOH ITEM NO METHOD PROCEDURE C G M R *"CALIBRATION BLOCK**

REF. DWG. NO.02-004'18600 TUBE BUNDLE B-Q ECT HDE 1.3 - - - X 11/9/95 - 8,213 tubes examined, 156 U-TUBES B16.20 indications, seven tubes plugged this outage for corrosion and wear progression

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 4 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS RIZER N I 0 ZONE NUMBER: 2-005 ASME OHGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE ,C G M R **CALIBRATIONBLOCK**

REF. DWG. HO. 02-005-B 018700 103-601 8-D UT 0 HDE 5.1-25 X - - - 10/23/95 . UT complete SPRAY NOZZLE TO UPPER HEAD B3.110 UT 45 NDE 5.1-26 X - --

UT 60 HDE 5.1-27 X --

UT 70 HDE 5.1-28 X - --

    • UT-4A**

REF. DMG. NO. 02-005-A 018800 SN-IR B.D UT 30 NDE 5.13-4 X - - - 10/23/95 - UT complete SPRAY NOZZLE INNER RADIUS B3.120 UT 70 HDE 5.13-6 X---

SECTION

    • UT-6, UT-17">>

REF. DMG. NO. 02-005-B 108-601-A 8-D UT 0 HDE 5.1-29 X - - - 10/24/95 - UT complete, acceptable slag SAFETY VALVE NOZZLE TO HEAD 83.110 UT 45 NDE 5.1-30 X---

UT 60 HDE 5.1-31 X UT 70 HDE 5.1-32 ---X UT 60 HDE 5.1-33 - - - X **UT-4A**

UT 70 HDE 5.1-34 - - X REF. DWG. NO. 02 005 A 019000 SVN-IR-A B-D UT 30 HDE 5.13-3 X - - - 10/23/95 - Ul'omplete SAFETY VALVE NOZZLE INNER 83.120 UT 70 NDE 5.13-5 X-RADIUS SECTION

  • >>UT-6, UT-17
  • 019100 503-671-A B-F PT HDE 3.3-44 X-- 10/20/95 - PT complete, 10/21/95 - UT NOZZLE TO FLANGE B5 ~ 40 UT 30 HDE 5.4-56 X- complete, limited examination from the UT 45 HDE 5.4-57 X-- nozzle side due to its configuration UT 45 HDE 5.4-58 X--
    • UT-17>>*

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UHIT 2 PAGE! 5 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS RIZER N I 0 NUMBER! 2-005 ASME ONGT SEC ~ XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS HUHBER IDENT IF ICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

REF. DWG. HO. 02-005-A 019200 SV-1200 B-G.2 VT-1 HDE 4.1-29 - - - X 10/25/95 - VT-1 complete, inadequate SAFETY VALVE FLANGE BOLTING 87.50 CNR 95-2-004 thread engagement on one nut, acceptable per letter JPN-PSL-88-070 REF. DWG. NO. 02-005-8 019300 108-601-8 8-D UT 0 NDE 5.1.25 X-- 10/23/95 - UT complete RELIEF VALVE NOZZLE TO UPPER 83.110 UT 45 NDE 5.1-26 X---

HEAD UT 60 NDE 5.1-27 X---

UT 70 NDE 5.1-28 X---

    • UT-4A<<*

REF. DWG. NO. 02-005-A 019400 RVH- I R B-D UT 30 NDE 5.13-3 X - - - 10/23/95 - UT complete RELIEF VALVE NOZZLE IHNER 83.120 UT 70 HDE 5 ~ 13-5 X . --

RADIUS SECTION

<<<<UT-6, UT-17<<*

REF. DWG. HO. 02-005-8 019500 108-601-C 8-D UT 0 NDE F 1-25 X--- 10/23/95 - UT complete SAFETY VALVE NOZZLE TO UPPER 83.110 UT 45 HDE F 1-26 X---

HEAD UT 60 NDE 5.1-27 X---

UT 70 HDE 5.1-28 X---

    • UT-4A"*

REF. DWG. HO. 02-005-A 019600 SVH-IR-8 8-D UT 30 NDE 5.13-3 X - - - 10/23/95 - UT coaplete SAFETY VALVE NOZZLE INNER 83.120 UT 70 NDE 5 '3-5 X---

RADIUS SECTION

<<*UT-6) UT-17

  • DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 6 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS RIZER N I 0 ZONE NUMBER: 2 005 ASME ONGT SEC ~ XI RSEH

SUMMARY

EXAMIHATIOH AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK*"

REF. DWG. NO. 02-005-A 019700 503-671-8 8-F PT NDE 3.3-44 X-- 10/20/95 - PT conplete, 10/21/95 UT SAFETY VALVE NOZ2LE TO FLANGE 85.40 UT 30 HDE 5.4 56 X complete, limited examination from the UT 45 HDE 5.4-57 X-- nozzle side due to its configuration UT 45 HDE 5.4-58 X--

    • UT-17
  • 019800 SV-1201 8-G-2 VT-1 HDE 4 ~ 1-28 X - - - 10/25/95 - VT-1 complete, 8 nuts and SAFETY VALVE FLANGE BOLTIHG B7.50 studs examined REF. DUG. No. 02-005-B 019900 108-601-0 B-D UI' NDE 5.1-25 X - - - 10/23/95 - UT complete SAFETY VALVE NOZZLE TO UPPER B3.110 UI'5 NDE 5.1-26 X - --

HEAD UT 60 HDE 5.'1-27 X - --

UT 70 NDE 5.1-28 X - --

<<<<UT-4A<<<<

REF. DUG. NO. 02-005-A 020000 SVN-IR-C 8-D UT 30 NDE 5.13-3 X - - - 10/23/95 - UT complete SAFETY VALVE NOZZLE INNER 83.120 UT 70 HDE 5.13-5 X---

RADIUS SECTION

<<*UT-6( UT-17

  • 020100 503-671-C 8-F PT HDE 3.3-44 X-- 10/20/95 - PT complete, 10/21/95 UT SAFETY VALVE NOZZLE TO FLANGE B5.40 UT 30 HDE 5.4-56 X-- complete, limited examination from the UT 45 HDE 5.4-57 X- nozzle side due to its configuration UT 45 NDE 5.4-58 X--

<<*UT 17*<<

020200 SV-1202 8-G-2 VT-1 NDE 4.1.27 X - - - 10/25/95 - VT-1 complete SAFETY VALVE FLANGE BOLTING 87.50

i 0

I 0

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE 7 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 'I CAEPBL STATUS COMPONENTS RIZER H I 0 ZONE NUHBER: 2-005 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK<<>>

REF. DWG. NO. 02-005-8 020300 MS-01 8-G-2 VT 1 M95-368 X - - - 11/15/95 - VI'-1 complete, examined 20 MANWAY STUDS 87.20 studs, examination performed by QC personnel 020400 MN-01 8-G-2 VT-1 M95-368 X - - - 11/15/95 - VT-1 complete, examined 20 MANWAY NUTS 87.20 nuts, examination performed by QC personnel REF. OWG. NO. 02-005-A 020500 501-671 8-8 UT 0 NDE 5.1-21 X - - - 10/21/95 - UT complete UPPER HEAD TO UPPER SHELL 82.11 UT 45 HDE 5 ~ 1-22 X---

UT 60 HDE 5.1-23 X---

UT 70 NDE 5.1-24 X---

<<*UT-4A**

0 101-622.A 8 8 UT 0 NDE 5.1-21 X - - - 10/21/95 - UT complete UPPER SHELL LOHGITUDIHAL WELD'2.12 UI'5 HDE 5.1-22 X-9 0 DEG. UT 60 NDE 5.1-23 X---

UT 70 HDE 5.1-24 X---

    • UT-4A**

WATER SPACE NOZZLES REF. DWG. HO. 02-005-8 022000 672-102 LER VT-1 HDE 4.1-'17 X - - - 10/9/95 - VT-1 complete, no evidence of TEMPERATURE NOZZLE 9 0 DEGREES 93-04 leakage I-1-RC-130 REF. DWG. NO.02-005 022100 V-1437 PRZ IHC VT-1 HDE 4.1-24 X - - - 10/9/95 - VT-'I cerpiete INSTRUMENTATION VALVE AUG-1

Jl DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 8 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPOHENTS RIZER N I 0 ZOHE NUMBER: 2-005 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REHARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

REF. DWG. HO. 02-005-B 022200 HA1 THRU HA4 LER VT-'I HDE 4.1-19 - - - X 10/9/95 - VT-1 complete, white substance HEATER PEHETRATIONS 93-04 found on vessel near heater penetration A3, not boric acid STEAM SPACE NOZZLES REF. DWG. NO. 02-005-B 022300 672-105A LER VT-1 NDE 4.1-23 X - - - 10/16/95 - VT-1 complete LEVEL NOZZLE 9 0 DEGREES 93-04 022350 672-105A B-E UT 60 NDE 5.22-13 X - - - 10/23/95 - UT complete NOZZLE TO VESSEL WELD 9 0 84.13 DEGREES

  • ~UT-62, Ul'-70**

0 672-105B LER VT-1 NDE 4.1-22 X - - - 10/16/95 - Vl'-1 complete LEVEL NOZZLE 8 180 DEGREES 93-04 022450 672-1058 B.E UT 60 NDE 5.22-13 X - - - 10/23/95 - UT complete NOZZLE TO VESSEL WELD 9 'IBO B4.13 DEGREES

  • ~UT 62) UT-70**

022500 672-105C LER VT-1 NDE 4.1-21 X - - - 10/16/95 - VT-1 complete LEVEL NOZZLE B 195 DEGREES 93-04 022550 672-105 C B-E UT 60 NDE 5.22-13 X - - - 10/23/95 - UT complete NOZZLE TO VESSEL WELD 9 195 B4 ~ 13 DEGREES

"*UT-62( UT-70**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 9 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPOHENTS RIZER H I 0 ZONE NUMBER: 2-005 ASME OHGT SEC. XI RSEH

SUMMARY

EXAMIHATIOH AREA CATGY EXAM E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

STEAM SPACE NOZZLES REF. DWG. NO. 02-005-B 022600 672-105D LER VT-1 NDE 4.1-20 X - - - 10/16/95 - VT-1 canplete LEVEL NOZZLE 9 345 DEGREES 93.04 022650 672-105D B-E UT 60 NDE 5.22-13 X - - - 10/23/95 - UT complete NOZ2LE TO VESSEL WELD 9 345 84.13 DEGREES

    • UT-62, UT-70**

WATER SPACE NOZZLES REF. DWG. NO. 02-005-B 022700 684-108A LER VT-'I HDE 4.1.16 X - - - 10/9/95 - VT-1 cceplete, no evidence of LEVEL NOZZLE 9 0 DEGREES 93-04 leakage BOTTOM HEAD 022800 684-1088 LER VT-1 NDE 4.1-18 X - - - 'ID/9/95 - VT-1 co@piete, no evidence of LEVEL NOZZLE 9 180 DEGREES 93-04 leakage BOTTOM HEAD

I I f

'l t

ly

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 10 REVI SIGH: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS R COOLANT PIPING LOOP B FROM RPV TO SG-2B N I 0 ZONE NUMBER: 2-007 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK**

I-42-RC-123 REF. DWG. NO.02-007 024300 RC-123-201-258 8-J MT NDE 2.2-28 X - - - 10/18/95 - MT complete, 10/19/95 - UT NOZZLE EXTEHSIOH TO ST. B9.11 UT 45 NDE 5.2-36 X - - - complete GEHERATOR NOZZLE UT 60 NDE 5.2-36 X. --

    • UT-4A**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 11 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COHPONENTS R COOLANT PIPING LOOP B SG-2B TO RCP-2B1 N I 0 ZONE NUHBER: 2-010 ASHE ONGT SEC ~ XI RSEN SUHHARY EXAHIMATION AREA CATGY EXAH E I 0 E REHARKS NUHBER IDENT IF ICATION ITEM NO HETHOD PROCEDURE C G H R ~*CALIBRATION BLOCK**

I-30-RC-121 REF. DWG. NO.02-010 027200 RC-121-401-258-8 B-J MT NDE 2.2-29 X - - - 10/18/95 - HT complete, 10/19/95 UT ST. GENERATOR NOZZLE TO NOZZLE 89.11 UT 45 NDE 5.2-37 X - - - complete, limited examination from the EXTENSION UT 60 NDE 5.2-38 X - - - nozzle side due to its configuration

    • UT 6~*

028600 RC-121-107-742.LS.A 8-J PT NDE 3.3-43 X - - - 10/19/95 - PT complete, 10/20/95 - UT ELBOW LONGITUDINAL SEAH B9.12 UT 45 NDE 5.4-68 X - - - complete, examined area next to weld UT 60 NDE 5.4-69 X - - - RC-121-1501-771-B A*UT 028700 RC-121-107-742-LS-8 8-J PT NDE 3.3-43 X - - - 10/19/95 - PT complete, 10/20/95 - Ul' ELBOW LONGITUDINAL SEAM B9.12 UT 45 NDE 5.4-68 - - - complete, examined area next to weld UT 60 NDE 5.4-69 X - - - RC-121-1501-771-B

    • UT 6**

0 RC-121-1501-771-8 B-F PT NDE 3.3-43 X--- 10/19/95 - PT complete, 10/20/95 - UT ELBOW TO SAFE END 85.130 UT 45 NDE 5.4-66 X--- complete, limited examination on the UT 45 NDE 5.4-67 X--- safe-end side due to its configuration UT 45 NDE 5.4-68 X---

UT 60 NDE 5.4-69 X--- **UT-59) UT-6**

028900 RC-121-4 8-J PT NDE 3.3.43 X- 10/'19/95 - PT complete, 10/20/95 - UT SAFE-END TO REACTOR COOLANT 89.11 UT 45 NDE 5.4-65 --X- complete, inside surface geometry, PUMP 281 UT 45 NDE 5.4-66 X- limited examination due to weld configuration, examined from the safe-end side only

    • UT 59k*

0 DATE: 02/23/96 ST ~ LUCIE NUCLEAR PLANT UNIT 2 PAGE: 12 REVI SION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS R COOLANT PIPING LOOP B FROM RCP-2B1 TO RPV N I 0 ZONE NUMBER: 2-011 ASME ONGT SEC. XI RSEN

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK**

I-30-RC-121 REF. DUG. HO.02-011 029100 RC-121-5 8-J PT HDE 3.3-41 X - - - 10/18/95 - PT coapiete, 10/20/95 - UT REACTOR COOLANT PUMP 281 TO 89.11 UT 45 HDE 5.4-70 - - X - complete, inside surface geometry SAFE-END UT 45 NDE 5.4-72 X --

    • UT 59**

029200 RC-121-901-771 B-F PT NDE 3.3-41 X--- 10/18/95 - PT complete, 10/20/95 UT SAFE-END TO PIPE 85.130 UT 45 NDE 5.4-71 X-- complete UT 45 NDE 5.4-72 X---

UT 60 NDE 5.4-73 X---

UT 45 NDE 5.4-74 X--- **UT-59, UT-6~*

029300 RC-121-103-722-LS-A B-J PT NDE 3.3-41 X - - - 10/18/95 - PT complete, 10/20/95 - UT PIPE LOHGITUDIHAL SEAM B9.12 UT 45 NDE 5.4-74 X - - - complete, examined area next to weld UT 60 NDE 5.4-73 X - - - RC-121-901-771

    • UT 64*

029400 RC-121-103-722-LS-B 8 J PT HDE 3.3-41 X - - - 10/18/95 - PT complete, 10/20/95 - UT PIPE LONGITUDINAL SEAM 89.12 UT60 AXIAL HDE 5.4-73 X - - - complete, examined area next to weld UT45 CIRC NDE 5.4-74 X - - - RC-121-901-771

    • UT 64*

1 1

L 1

0

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS A1 SAFETY INJECTION PIPING INSIDE O'TMT N I 0 20NE NUMBER: 2-021 ASME OHGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

I-6-SI-516 REF. DWG. NO.02-021 046200 V-3258 B-M-2 VT-3 NDE 4.3-97 X - - - 10/23/95 - VT-3 complete VALVE INTERNAL SURFACE B12.50

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE 14 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COHPONENTS A2 SAFETY INJECTION PIPING INSIDE CTMT N I 0 ZONE NUMBER: 2-022 ASME ONGT SEC. XI RSEN SUHMARY EXAMINATION AREA CATGY EXAH E I 0 E REMARKS NUMBER IDENTIFICATION ITEH NO METKOD PROCEDURE C G M R <<*CALIBRATION BLOCK**

I-12-RC-154 REF. DUG. NO.02-022 05'1300 V-3217 8-G-2 VT-1 NDE 4.1-33 X - - - 11/1/95 - VT-1 complete, 11/6/95 - 18 CHECK VALVE BOLTING 87.70 VT-1 MM95-1692 X - - - studs and nuts examined in place, examination performed by QC personnel 051400 V-32'l7 B-H-2 VT-3 NDE 4.3-108 11/1/95 - VT-3 complete, uear located at VALVE INTERNAL SURFACE B12.50 CNR 95-2-006 valve and disk seat area, bottom and sides of bearing block housing, seat lapped and new disk installed

'l I

9 4 ~.

'I II

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 15 REVISION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND iNTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS B2 SAFETY INJECTION PIPING INSIDE CTMT N I 0 ZONE NUMBER: 2-024 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT IF ICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

1-12-SI-151 REF. DIIG. HO.02-024 058100 V-3644 8-G-2 VT-1 NDE 4.1-30 X - - - 10/30/95 - VT-1 complete, 18 studs and GATE VALVE BOLTING 87.70 nuts examined 058300 SI -151-Fll-1 8-J PT NDE 3.3-57 X-- 10/30/95 PT and UT complete, root VALVE V-3644 TO PIPE 89.11 UT 45 NDE 5.4-98 X-- geometry, limited examination from the UT 45 NDE 5.4-99 X-- pipe side due to the weld configuration UT 60 NDE 5.4-100 --X

    • UT 354*

058420 SI -4203-581A F-A VT-3 HDE 4.3-107 X - - - 10/30/95 - VT-3 complete RIGID FRAME SUPPORT F1.10 1-6-SI-518 REF. DWG. HO.02-024 00 V-3261 B-G-2 VT-1 HDE 4.1-31 X - - - 10/30/95 - VT-1 complete, 16 studs and CHECK VALVE BOLTING 87.70 nuts examined 058900 SI-518-Fu-1 B-J PT HDE 3.3-57 X - - - 10/30/95 - PT and UT complete, root VALVE V-3261 TO PIPE 89.11 UT 45 HDE 5.4-94 X - - - geometry UT 45 NDE 5.4-95 X---

UT 60 NDE 5.4-96 X-UT 70 NDE 5.4-97 X- ~*UT-38**

1-12-S1-151 REF. DMG. NO.02-024 059740 S1-4203-67 F-A VT-3 HDE 4.3-106 - - - X 10/30/95 - VT-3 complete, 11/8/95 - VT-3 Spring Support F1.50 VT-3 NDE 4.3-'112 X - - - re-examination complete after adjust CNR 95-2-005 STAR 951638 PMO 8222 NO 95013842

P P g,

+ 4

~ t I

'ff 0

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 16 REVI SION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS B2 SAFETY INJECTION PIPING INSIDE CTMT N I 0 ZONE NUMBER: 2-024 ASHE ONGT SEC. XI RSEH SUHHARY EXAMIHATION AREA CATGY EXAH E I 0 E REMARKS NUHBER IDENTIFICATION ITEH HO HETKOD PROCEDURE C G H R <<<<CALIBRATION BLOCK**

I-12-SI-151 REF. DMG. NO.02-024 060100 SI-4203-71 8-K-1 PT HDE 3.3-57 X - - - 10/30/95 - PT complete, examined 8 INTEGRAL ATTACHHENTS 810.10 integral attachments on the accessable 3 sides 060400 S I -151- FH-4 B-J PT HDE 3.3-57 X - - - 10/30/95 - PT and UT cceplete, root PIPE TO VALVE V-3247 B9.11 UT 45 NDE 5.4.98 X - - - geometry, limited examination from the UT 45 HDE 5 '-99 X - - - pipe side due to the weld configuration UT 60 NDE 5.4-100 - - X-

  • <<UT-35**

l Ll

=r I

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 17 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS ED PRESSURIZER SPRAY LINE N I 0 ZONE NUMBER: 2-025 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK**

I-4-RC-103 REF. DWG. HO.02-025 063140 SPS-787 F-A VI'-3 HDE 4.3-96 X - - - 10/21/95 - VT-3 complete RIGID STRUT F1.10 063600 RC"103C-SW-1 8-J PT HDE 3.3-45 X - - - 10/20/95 - PT complete, 10/23/95 - UT Pipe to Tee 89.11 UT 30 HDE 5.4-62 X - - - complete UT 45 HDE 5.4-64 X---

UT 60 NDE 5.4-63 X-

~~UT-40**

063700 RC-103C-SW-3 8-J PT NDE 3.3-45 X--- 10/20/95 - PT complete, 10/23/95 - UT Reducer to Tee 89.11 UT 30 HDE 5.4-62 X--- complete UT 45 HDE 5.4-64 X--

UT 60 NDE 5.4-63 X--

    • UT-40**

0 RC-'I03C-SW-2 8-J PT NDE 3.3-45 X - - - 10/20/95 - PT complete, 10/23/95 UT Tee to Pipe 89.11 UT 30 NDE 5.4 59 X - - - complete, root geometry UT 45 NDE 5.4-60 --X-UT 60 NDE 5.4-61 -X-

    • UT 40**

063900 RC-103-FW-903 8-J PT NDE 3.3-45 X - - - 10/20/95 - PT complete, 10/23/95 - UT PIPE TO SAFE-END 89.11 UT 30 HDE 5.4-62 X - - - complete UT 45 NDE 5.4-64 X- --

UT 60 HDE 5.4-63 X.--

    • UT 40**

064000 RC-504-671 8-F PT NDE 3.3.45 X - - - 10/20/95 - PT complete, 10/23/95 UT SAFE-EHD TO SPRAY NOZZLE 85.40 UT 45 NDE 5.4-77 X - - - complete, counterbore geometry UT 45 HDE 5.4-78 X

    • U'I-19**

I II I' C

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 18 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS

.8 SHUTDOWN COOLING LINE N I 0 20NE NUMBER: 2-028 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

I-12-RC-147 REF. DMG. NO. 02-028-A 074600 RC-147-1-SW-8 B-J PT NDE 3.3-58 X--- 10/31/95 - PT and UT complete, root 3" SllEEPOLET 89.32 UT 45 NDE 5.4-101 X--- geometry UT 45 NDE'5.4-102 X---

UT 60 NDE 5.4-103 --X-

    • UT 35**

I-10-RC-302 REF. DUG. NO. 02-028-B 076450 SI-4205-6408 F-A VT-3 NDE 4.3-109 ---X 11/2/95 - VT-3 complete, loose lock nut Spring Support F1.50 VT-3 NDE 4.3-111 X--- and incomplete thread engagement, CNR 95-2-007 11/8/95 VT-3 re-examination complete PIS 8222 after tightening MO 95013839 076500 SI-4205-6408 8-K-1 PT NDE 3.3-59 X - - - 11/3/95 - PT coaplete, limited INTEGRAL ATTACHMENTS 810.10 examination due to hanger clamp, examined 3 accessible sides I-10-SI-130 REF. DUG. NO. 02-028-8 077600 SI-130-1-SN.6 8-J PT NDE 3.3-61 X - - - 1'I/14/95 - PT complete 2" BRANCH CONNECTION 89.32 I-3-SI-191 REF. DUG. NO. 02-028-A 080700 SI-191-FW.3 8-J PT NDE 3.3-58 X - - - 10/31/95 - PT complete PIPE TO VALVE V-3527 89.21 080900 SI -191- FN-2 8-J PT NDE 3.3-58 X - - - 10/31/95 - PT complete VALVE V-3527 TO PIPE 89.21

I II I '

I I I,

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION: 0 INSERVICE IHSPECTIOH RESULTS FOR THE SECOHD INTERVAL, FIRST PERIOD, SECOHD OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS B SHUTDOWN COOLING LIME N I 0 ZONE NUMBER: 2-028 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM HO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK">>

I-3-SI-191 REF. DWG. NO.02-028.A 081000 SI-191-1-S'W.1 B.J PT NDE 3.3-58 X - - - 10/31/95 - PT complete Pipe to Elbow 89.21 081750 SI-4206-6361 F-A VT-3 NDE 4.3-110 X - - - 11/2/95 - VT-3 coaplete RIGID STRUT SUPPORT F1.10

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS A SHUTDOWN COOLING LINE N I 0 ZONE NUMBER: 2-029 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATIOH AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT I F I CATION ITEM HO METHOD PROCEDURE C G M R <<<<CALIBRATION BLOCK**

1-10-SI-127 REF. DWG. HO. 02-029-B 089300 V-3481 8-M-2 VT.3 HDE 4.3-98 X - - - 10/26/95 - VT-3 complete VALVE INTERHAL SURFACE 812.50

I l

I

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UHIT 2 REVI SION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS RIZER AUXILIARY SPRAY N I 0 ZONE NUMBER: 2-030 ASHE ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUHBER IDENTIFICATION ITEM HO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK~*

I-2-CH-146 REF. DWG. NO. 02-030-8 091600 CH-146 SW-1 8-J PT NDE 3.3.49 X - - - 10/23/95 - PT complete VALVE SE-02-03 TO PIPE 89.21 091700 CH-146-SW-2 8-J PT NDE 3.3-49 X - - - 10/23/95 - PT complete Pipe to Tee 89.40 09'1900 CH-146-SW.4 8-J PT NDE 3.3-49 X - - - 10/23/95 - PT complete Tee to Pipe 89.40 092000 CH-146-SW-5 8-J PT NDE 3.3-49 X . . . 'IO/23/95 - PT complete 89.40 I-2-CH-347 REF. DWG. NO. 02-030-8 092100 CH-347-SW-1 8-J PT HDE 3.3-49 X - - - 10/23/95 - PT cceyiete VALVE SE-02-04 TO PIPE 89.21 092200 CH-347-FW.2 8-J PT NDE 3.3-49 X . - . 10/23/95 - PT complete Pipe to Tee 89.40 I-2-CH-146 REF. DWG. NO. 02-030-8 092300 CH-146-FW.6 8-J PT NDE 3.3.50 X - . - 10/23/95 - PT complete Tee to Pipe 89.40

~ i 'I 1I L

~I

~

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 22 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVALED FIRST PERIODS SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COHPONENTS RIZER AUXILIARY SPRAY N I 0 ZONE NUHBER: 2-030 ASME ONGT SEC. XI RSEH SUHHARY EXAMINATION AREA CATGY EXAH E I 0 E REMARKS NUMBER IDENT IF ICATION ITEH NO HETHOO PROCEDURE C G M R **CALIBRATIONBLOCK~~

I-2-CH-146 REF. DWG. NO. 02-030-8 092400 CH-146-S'W-7 8-J PT NDE 3.3-50 X - - - 10/23/95 - PT complete Pipe to Tee 89.40 092500 CH-146-SW-10 8-J PT NDE 3.3-50 X - - - 10/23/95 - PT complete REDUCER TO ELBOW 89.40 092600 CH-146-SW.9 8-J PT NDE 3.3-50 X - - - 10/23/95 - PT complete Elbow to Pipe 89.40 092700 CH-146.SW-B 8-J PT NDE 3.3-49 X - - - 10/23/95 - PT complete 1 89.40 092800 CH-146-FW-11 8-J PT HDE 3.3-49 X - - - 10/23/95 - PT co@piete Tee to Pipe 89.40 I-2-CH-146 REF. DWG. NO.02-030.

093760 CH-107-R7 F.A VT-3 NDE 4.3-104 X - - - 10/27/95 - VT-3 complete VARIABLE SPRING BASE F1.50 I-2-RC-149 REF. DWG. NO. 02-030-A 094600 RC-149-FW.2 8-F PT NDE 3.3-47 X - - - 10/20/95 - PT complete Pipe to Reducer 85.140

E DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 23 REVISION: 0 IHSERVICE IHSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS B1 PRIMARY DRAIH N I 0 ZONE NUMBER: 2-035 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R ~*CALIBRATION BLOCK**

I-2-RC-122 REF. DUG. HO.02-035 111200 RC-122.FN.1 8-J PT NDE 3.3-42 X - - - 10/19/95 - PT coagulate SAFE-EHD TO PIPE B9.21 111800 2-RC-122-FB B-G-2 VT-1 NDE 4.1-26 - - - X 10/19/95 - VT-1 coaplete, one bolt flush FLANGE BOLTIHG 87.50 CNR 95-2-003 with nut, acceptable per engineering evaluation JPH-PSL-88-070

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 24 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS 82 PRIMARY DRAIN N I 0 ZONE NUMBER: 2-036 ASHE ONGT SEC. XI RSEH SUHHARY EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUHBER IDENT I F ICATION ITEM NO METHOD PROCEDURE C G H R **CALIBRATIONBLOCK*"

I-2-RC-125 REF. OWG. NO.02-036 112600 2-RC-125-FB B-G-2 Vr-1 NDE 4 ~ 1-25 X - - - 10/19/95 - VT-1 complete FLANGE BOLTING 87.50

1 k N 41 I h

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE 25 REVISION: 0 INSERVICE INSPECTION RESULTS FOR TNE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS N LINE FROH LOOP 281 N I 0 ZONE NUMBER: 2-037 ASHE ONGT SEC. XI RSEN SUHHARY EXAMI NAT ION AREA CATGY EXAM E I 0 E REHARKS NUHBER IDENTIFICATION ITEM NO HETHOD PROCEDURE C G M R **CALIBRATIONBLOCK**

I-2-CM-145 REF. DUG. NO. 02-037-B 116900 V-2516 VT-1 NDE 4.1-32 X - - - 10/27/95 - VT-1 complete VALVE BOLTING

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UHIT 2 PAGE: 26 REVI SION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 1 CAEPBL STATUS COMPONENTS RIZER RELIEF LINE N I 0 ZONE NUMBER: 2-038 ASME ONGT SEC. XI RSEM

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT IF I CAT IOH ITEM HO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK**

I 4-RC-101 REF. DWG. HO.02-038 119200 RC-506-671 8-F PT NDE 3.3-46 X - - - 10/20/95 - PT complete, 10/24/95 UT NOZZLE TO SAFE-EHD 85.40 UT 45 NDE 5.4-75 X - - - complete UT 45 HDE 5.4-76 X---

    • UT-17
  • I-3-RC-309 REF. DWG. HO.02-038 120150 RC-4300-9 F-A VT-3 NDE 4.3-114 X - - - 11/20/95 - VT-3 complete Spring Support F1.50 I-3-RC-310 REF. DWG. NO.02-038 121550 RC-4300-70 F-A VT-3 NDE 4.3-1'13 X - - - 11/20/95 - VT-3 complete Spring Support F1.50

DATE: 02/23/96 ST ~ LUCIE NUCLEAR PLANI'NIT 2 PAGE: 27 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COMPONENTS UMP 2A DISCHARGE HEADER PIPING N I 0 ZONE NUMBER: 2-043 ASME OHGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENT IF I CAT IOH ITEM NO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK*~

I-6-SI-113 REF. DHG. NO. 02-043-D 138650 S I -2408-9 F-8 VT-3 HDE 4.3-105 X - - -, 10/27/95 - VT-3 complete RIGID FRAME SUPPORT F1 ~ 10 138800 S I -113- Fll-5 C-F-1 PT HDE 3.3-56 X - - - '10/27/95 - PT and UT coaylete, root ELBOM TO ELBN C5.11 UT 45 HDE 5.4-92 X - - - geometry UT 60 HDE 5.4-93 - - X-ttUT 38*%

'138900 SI -113-5-Ql-1 C-F-1 PT HDE 3.3.56 X - - - 10/27/95 - PT and UT complete, root Elbow to PIpe C5.11 UT 45 HDE 5.4-92 X - - - geometry UT 60 HDE 5.4.93 - - X-

    • UT-38**

SI -113-FH-6 C-F-1 PT NDE 3.3-56 X - - - 10/27/95 - PT and UT complete, root PIPE TO PENETRATION 36 C5.11 UT 70 HDE 5.4-90 X - - - geometry UT 45 5.4-91 X - --

UT 45 NDE NDE 5.4-92 X - --

UT 60 NDE 5.4-93 - - X - **UT-38**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UHIT 2 PAGE: 28 REVISION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COMPONENTS INJECTION PIPING TO SI TANK 2A2 N I 0 ZONE NUMBER: 2-045 ASHE ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUHBER IDENT IF ICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIOHBLOCK>>>>

I-6-SI-113 REF. DUG. NO.02-045 168400 S1-4200-322C CC PT HDE 3.3-55 X - - - 10/26/95 - PT complete, examined 8 INTEGRAL ATTACHMENTS C3.20 integral attachments, no examination fran one side due to support clamp

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 29 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COHPOHENTS COOLING HEAT EXCHANGER 2A N I 0 ZONE NUHBER: 2-055 ASHE ONGT SEC. XI RSEH SUHHARY EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION I TEH HO HE'THDD PROCEDURE C G M R **CALIBRATIONBLOCK**

REF. DUG. HO.02-055 209200 1-2701 C-A UT 45 NDE 5.2-39 X - - - 10/27/95 - UT complete, limited FLANGE TO BODY C1 ~ 10 UT 60 NDE 5.2-40 X - - - examination due to nozzles and flange configuration

    • UT-52**

209300 1-2702 C-A UT 45 NDE 5.2-39 X - - - 10/27/95 - UT complete, limited BODY TO TUBESHEET C1.30 UT 60 HDE 5.2-40 X - - - examination due to nozzles and tubesheet configuration

+*UT-52*+

209500 1-2741-2 C-B HT HDE 2.2-30 X - - - 10/26/95 - HT cceyiete PAD TO VESSEL C2.31 0 1-2741-3 CB MT HDE 2.2-30 X - - - 10/26/95 - HT complete PAD TO VESSEL C2.31 209800 1-2742-2 C-B HT NDE 2.2-30 X - - - 10/26/95 - HT complete PAD TO VESSEL C2.31 209900 1-2742-3 C-B MT HDE 2.2-30 X - - - 10/26/95 - HT complete PAO TO VESSEL C2.31

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 30 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COHPONENTS EEDMATER TO SG 2A1 INSIDE CONTAINMENT N I 0 ZONE NUHBER: 2-067 ASHE ONGT SEC. XI RSEH SUHHARY EXAMIHATION AREA CATGY EXAH E I 0 E REHARKS NUHBER IDENTIFICATION ITEH NO METHOD PROCEDURE C G H R <<*CALIBRATION BLOCK~*

I-18-BF-51 REF. DMG. NO.02-067 252100 BF-4007-6081 C-C HT NDE 2.2-27 X - - - 10/16/95 - HT complete, one integral INTEGRAL ATTACKHENT C3.20 attachment examined

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COHPONENTS EEDNATER TO SG 281 INSIDE CONTAINHENT N I 0 ZONE NUMBER: 2-068 ASHE ONGT SEC. Xl RSEN SUMHARY EXAHINATION AREA CATGY, EXAM E I 0 E REMARKS NUHBER IDENTIFICATION ITEH NO HETNOD PROCEDURE C 0 H R **CALIBRATIONBLOCK*>>

I-18-BF-52 REF. DUG. NO.02-068 255300 BF-4006-6076 C-C HT NDE 2.2-26 X - - - 'IO/16/95 - MT complete INTEGRAL ATTACHHENT C3.20

DATE: 02/23/96 ST. LUCIE HUCLEAR PLANT UNIT 2 PAGE: 32 REVISION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF) ~

CLASS 2 CAEPBL STATUS COMPONENTS ED HPSI DISCHARGE H I 0 ZONE NUMBER: 2-087 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK~*

I-3-SI-179 REF. DWG. NO. 02-087-A 361250 SI-2416-352 F-8 VT-3 HDE 4.3-99 X - - - 10/24/95 - VT-3 complete ANCHOR F1 ~ 10 361300 S I -2413-352 C-C PT NDE 3.3.54 X - . - 10/24/95 - PT complete INTEGRAL ATTACHMENTS C3.20 I-3-SI-179 REF. DWG. HO. 02-087-B 364100 S I -179- FW-910 C-F-1 PT NDE 3.3-53 X - - - 10/24/95 - PT complete, 10/25/95 - UT Pipe to Elbow CS ~ 21 UT 45 NDE 5.4.85 X - - - complete UI'0 NDE 5.4.89 X - --

    • 3-SS-160..434.22**

SI-179-8-SW-1 C-F-1 PT HDE 3.3-53 X - - - 10/24/95 - PT complete, 10/25/95 UT Elbow to Pipe C5.21 UT 45 NDE 5.4-85 X - - - complete, root geometry UT 60 HDE 5.4-86 - - X-

    • 3-SS-160-.434-22*

365200 SI -179-FW-10 C-F-1 PT NDE 3.3-53 X - - - 10/24/95 - PT complete, 10/25/95 UT PIPE TO PENETRATIOH 69 C5.21 UT 45 NDE 5.4-85 X - - - complete, inside surface geometry UI'0 HDE 5.4-87 X - --

UT 60 HDE 5.4-88 - - X-

    • 3-SS-160-.434-22**

I-2-SI-109 REF. DWG. NO. 02-087-C 365300 SI-109-F'W-1 C-F-1 PT HDE 3.3-52 X - - . 10/24/95 - PT complete, 10/25/95 - UT Reducer to Pipe C5.21 UT 45 NDE 5.4-82 X - - - complete, root geometry UT 60 NDE 5.4-83 X - --

UT 70 NDE 5 '-84 - - X-

    • 2-SS-160-.342-20**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 33 REVISION: 0 INSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COMPONENTS ED HPSI DISCHARGE N I 0 ZONE NUMBER: 2-087 ASME ONGT SEC. XI RSEN, SUMHARY EXAMIHAT ION AREA CATGY EXAM E I 0 E REMARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R **CALIBRATIONBLOCK~*

I-2-S1-109 REF. DWG. NO. 02-087-C 365400 Sl-109-SM-2 C-F-1 PT NDE 3.3-52 X - - - 10/24/95 - PT complete PIPE TO VALVE HCV-3647 C5.30 I-2-SI-215 REF. DWG. NO. 02-087-J 375600 SI-215-FM-2 C-F-1 PT NDE 3.3-51 X 10/24/95 - PT complete, one acceptable Reducer to Pipe C5 ~ 21 UT 45 NDE 5.4-79 X-- round indication, 10/25/95 - UT UT 60 NDE 5.4-80 X-- coapiete, root geometry UT 70 NDE 5.4-81 --X

    • 2-SS-160-.342-20**

DATE: 02/23/96 ST. LUCIE NUCLEAR PLANT UNIT 2 PAGE: 34 REVISION: 0 IHSERVICE INSPECTION RESULTS FOR THE SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (95RF)

CLASS 2 CAEPBL STATUS COMPOHENTS NG PUMP 2A DISCHARGE TO AUX MPSI H I 0 ZONE NUMBER: 2-088 ASME ONGT SEC. XI RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R ~*CALIBRATIOH BLOCK**

I-2-CH-104 REF. DWG. HO. 02-088-B 381625 CH-104-FII.600 C.F.1 PT QCR MM95-1817 X - - - 11/13/95 - PT complete, examination PIPE TO VALVE V-2169 C5.30 performed by QC personnel 38'l660 V-2169 N/A N/A 11/11/95 - Valve Has replaced CHECK VALVE 381675 CH-104-FM-601 C-F-1 PT QCR MM95-1817 X - - - 11/13/95 - PT complete, examination VALVE V.2169 TO PIPE C5.30 pe'rformed by QC personnel

St. Lucie Unit

~

~ ~

2 L-96-72 Docket No. 50-389 Fall 1995 Refueling Outage NIS-1 ATTACHMENT 2 1995 EDDY CURRENT

SUMMARY

REPORT

Page1 of 1 FORM NIS BB OWNERS'ATA REPORT FOR EDDY CURRENT EXAMINATIONRESULTS As required by the provisions of the ASME CODE RULES EDDY CURRENT EXAMINATIONRESULTS PLANT: St. Lucle Unit 2 EXAMINATIONDATES: NOVEMBER 1, 1995 through NOVEMBER 9, 1995 TOTAL TUBES TUBES TOTAL TOTAL INDICATIONS PLUGGED AS PLUGGED PLUGGED STEAM TUBES PREVENTIVE THIS TUBES GENERATOR EXAMINED 20% - 39% 40% 100% MAINTENANCE OUTAGE IN S/G 8142 231 274 8213 152 209 LOCATION OF INDICATIONS (20% - 100%)

U BENDS EGGCRATES PARTIAL SUPPORTS TOP OF TUBE SHEET STEAM 1TO7 8 AND 9 TO 41 EGGCRATE GENERATOR DHB to DCB H/L C/L H/L C/L H/L C/L A 222 2 6 3 2 1 0 B 143 2 3 Remarks:

S/G 'A': (1) ONE TUBE PREVENTIVELYPLUGGED DUE TO MRPC EZI INDICATION.

S/G 'B'REVENTIVELYPLUGGED TUBES INCLUDE:

(2) THREE TUBES PLUGGED DUE TO CORROSION DAMAGE IN Tl S SLUDGE PILE REGION FOUR TUBES PLUGGED FOR FLAWS SHOWING WEAR PROGRESSION AT DIAGONALS (3)

AND (1) VERTICALSTRAP (VS2)

DATE: Zo PK PREPARED BY:

G E CU ENT COORDINATOR DATE'ATE'EVIEWEDBY: I SPECTIONS SUP RVISOR REVIEWED BY:

S/8 TE NICALS ECIALIST fcnns lUhiabbsO.~

0

" L j

'L n "l

') P a g ) I, 4< 4

~ g 1q

CUMULATIVE DISTRIBUTION

SUMMARY

ST LUCIE UNIT P 2 10/95 COMPONENT : STG gA Page : 1 Date : 11/16/95 Examination Dates  : 11/02/95 thru 11/09/95 Total Number of Tubes Examined 8142 Total Indications Between 20% and 39: 231 Greater than or equal to 40: 5 Total Tubes Plugged as Preventive Maint Total Tubes Plugged >= 40%

Total Tubes Plugged from MRPC Examination for Top of Tubesheet Indication Total Tubes Plugged This Outage.........:

Location Of Indications 204 to 100%

Hot Leg Cold Leg TSH .5 to 01H -2.1 1 TSC .5 to 01C -2.1 01H -2.0 to 07H +2.0 2 01C -2.0 to 07C +2.0 07H +2.1 to DHB -3. 1 3 07C,+2.1 to DCB -3.1 DHB -3.0 to DCB -3. 0 222

CUMULATIVE DISTRIBUTION

SUMMARY

ST. LUCIE UNIT 8 2 10/95 COMPONENT : STG gB Page : 1 Date : 11/16/95 Examination Dates  : 11/01/95 thru 11/09/95 Total Number of. Tubes Examined 8213 Total Indications Between 204 and 39% 152 Greater than or equal to 404 4 Total Tubes Plugged as Preventive Maint Total Tubes Plugged ) 40 o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Total Tubes Plugged from MRPC Examination for Top of Tubesheet Indications Total Tubes Plugged This Outage

  • Note: Tube 69-83 was plugged due to a bobbin coil response of 434 9 TSH +0.6. This tube also showed a pluggable "I" code (ASI) at the same location.

Location Of Indications 204 to 100>

Hot Leg Cold Leg TSH .5 to 01H -201 6 TSC .5 to 01C -2.1 01H -2.0 to 07H +2.0 2 01C -2.0 to 07C +2.0 07H +2.1 to DHB -3.1 2 07C +2.1 to DCB -3.1 DHB -3.0 to DCB -3 0 143

INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COHPONENT  : STG fIA Page DESCRIPTION : 20% TO 100% Date : 11/16/95 Time : 08:38:52 I I Extent I 10/95 N/A IRowl LinlLeglReqlTst/Hotel Reel Probe Location IvoltslDeglch I % IDiffl Location lvoltslDeglch I % I

+---I --- I--- I-- I-------I- I I I 891 211 H ITECITEC PSIAH070 IA-580.H/ULC IVS2 .7 I 71 II 21 221 as/ 221 H ITEGITEc IAH070 IA-580.H/ULC IVS3 - 7 1.sl IP zl I

I 901 241 H ITECITEC PSIAH070 IA-580.H/ULC IVS3 -.6 I 61 II 21 211 I 611 I H ITECITEC PSIAHOS IA-580-M/ULC IVS4 I 61 II zl 221 I 921 261 H ITECITEC PSIAH093 IA-580-H/ULC IVS3 .9 I .61 I>>l 211 I I I I H ITECITEC PSIAH093 IA-580.M/ULC IVS4 .7 I .71 II zl 231 I I I I H ITECITEC PSIAH093 IA-580-M/ULC 105C - 7 1.211321 11 271 I 881 281 H ITECITEC PLIAH066 IA-580-H/ULC IVS3 -1.2 ~ 61 IP 21 231 I I I H ITECITEC PCIAH066 IA-580-H/ULC IVS4 .sl II zl 201 I I H ITECITEC PCIAH066 IA-580-M/ULC IVS4 .71 II 21 231 I 981 281 H ITECITEC PSIAH089 IA 80 H/ULC IVS .81 II 21 z61 I 811 291 H ITECITEC PSIAH089 IA-580-M/ULC IVS3 -.8 IP 21 301 I I I H ITECITEC PSIAH089 IA-580.M/ULC IVS3 .81 IP 21 zsl I I I I H ITECITEC PSIAH089 IA-580.H/ULC IVS3 .8 .71 IP zl 231 I I I I H ITECITEC PSIAH089 IA-580-H/ULC IVS4 1.0 .71 IP 21 z41 I I 961 301 H ITECITEC PCIAH066 IA-580 H/ULC IVS2 1 ' .sl IP 21 z11 I I I I H ITECITEC PCIAH066 IA-580-H/ULC IVS4 .sl I>>I 201 I I 981 301 H ITECITEC PSIAH089 IA-580 H/ULC IV 2 .4 .51 II 21 zol I 110sl 331 H ITECITEC PSIAH089 IA-580-H/ULC IVS2 .sl IP zl zzl I I 921 341 H ITECITEC PCIAH066 IA-580.H/ULC IVS4 -.4 1.21 II 21311 I I 961 341 H ITECITEC PSIAH066 IA-580.H/ULC IVS2 - 7 I

I s11 351 H ITECITEC PCIAH087 IA-580-H/ULC IVS3 -.6 .71 IP 21 zsl I I 881 361 H ITEGITEC PSIAH066 IA-580.H/ULC IVS4 -.9 II zl 221 I 11011 371 H ITECITEC PSIAH089 IA-580.M/ULC IVS3 1.8 .911391 11 211 I I 11 391 C ITEHITEH PCIAC099 IA-560-SF/RH ITSH 1.3 ~ 411331 11 301 I I azl 441 C ITEHITEH PLIAC048 IA-580-M/ULC IVS2 .8 ~ 91 li z13sl I 471 H ITECITEC PLIAH068 IA-580-H/ULC IVS2 -.8 ~ sl li 21 zol I I I I H ITECITEC PCIAH068 IA-580-M/ULC IVS3 -.6 F 01 li zl 291 I I I I H ITECITEC PCIAH068 IA-580-M/ULC IVS4 .9 ~ 91 IP 21 zel I I 31 491 C ITEHITEH PSIAC099 IA-560-SF/RH 102C -.8 .71 II 21 221 I 491 H ITECITEC PCIAH103 IA-580.M/ULC IVS3 1 ~ 1 .61 IP 21 241 I 751 491 C ITEHITEH PSIAC053 IA-580.H/ULC IVS3 - 3 ~ sl IP 21 201 I I I 481 01 C ITEHITEH PSIAC002 IA-580-H/ULC IVS3 -.8 .sl II 21 221 I 501 H ITECITEC PSIAH068 IA-580.H/ULC IVS1 1.0 II 21 zzl I I I I H ITECITEC PSIAH068 IA-580.M/ULC IVS2 -.6 1.01 II zl 291 I 11z61 Ol K ITECITEC PSIAH091 IA-580-M/ULC IVS1 ~ 9 ~ sl IP 21 zsl I I 781 521 C ITEHITEH PSIAC048 IA-580-H/ULC IVS4 -.8 hei li 21311 I 521 C ITEHITEH PSIAC053 IA 80 M/ULC IVS2 - 7 ~ sl II 21 zol I I I I C ITEHITEH PSIAC053 IA-580.M/ULC IVS3 .0 1.41 Ir 21 311 I I I I C ITEHITEH PGIAC053 IA 8 H/ULC IVS -.6 ~ 91 IP 21 241 I 11261 541 H ITECITEC PSIAH091 IA-580.H/ULC IVS1 .9 .sl II 21 zsl I 491 551 C ITEHITEH IAC003 IA-580.H/ULC IVS3 - 9 .81 IP 21 211 I-I 11231 551 C ITEHITEH PSIAC047 IA-580.M/ULC IVS1 -1.0 ~ 41 II zl 201 I I

- I-I I I

-I--

REPORT 100'NDICATIONS/TRENDING PSL-2 OUTAGE  : 10/95 COMPONENT  : STG fIA Page 2 DESCRIPTION  : 20K To Date : 11/16/95 Time : 08:38:56 I I Extent I I 10/95 I I N/A IRowlLinlLeglReqlTst/ kotel Reel Probe Location IvoltslDeglch X IDiffl Location Ivoltsloeglch I X I

+ I I

---I- -I- I I I


I---I---I. I I

I131I 55I C ITEHITEH SCIAC051 IA-580 M/ULC IDCB .0 .sl Ii al 21I I 89I 57I C ITEHITEH PSIAC006 IA-SBO.M/ULC IVS2 .9 Ii al 21I I 9sl 5rl C ITEHITEH PLIAC053 IA-SSO.M/ULC IVS2 -.8 .5I Ii al aol I129I 57I C ITEKITEH PSIAC047 IA-580.M/ULC IDCT .0 .7I Ii al 24I I 92I 58I C ITEHITEH PSIAC053 IA-580.M/ULC IVS4 1.0 IP al 3ol I I I C ITEHITEH PSIAC053 IA-580.M/ULC IVS4 ~ 2 Ii al 34I I 96I 58I C ITEKITEH PSIAC053 IA-580.M/ULC IVS3 -.8 ~ sl li al as/

I 93I 59I C ITEHITEH PSIAC048 IA-580.M/ULC IVS4 -.6 ~ 5I li al 24I I12rl 59I C ITEHITEH PSIAC047 IA 580 M/ULC IVS1 1.0 .sl li al 23I I rel sal C ITEHITEH PSIAC052 IA-580 M/ULC IVS2 1.0 .Sl li al as)

I I I C ITEHITEH PSIAC052 IA-580-M/ULC IVS3 .9 .sl Ii al 23I I 96I sal C ITEHITEH PCIAC059 IA-580.M/ULC IVS3 -.7 ~ 5I IP al aol I 39I 63I C ITEHITEH Sc IAc003 IA-580-M/ULC IVS3 -1.0 IP 2I 22I I 93I 631 C ITEHITEH PSIAC IA-580-M/ULC lvsa -1 ~ 1 ~ 5 I Ii al aol 1133I 63I C ITEHITEH PSIAC IA-580-M/ULC lvsi .e ~ rl Ii al 23I I135I 63I C ITEHITEH IAC045 IA-580-M/ULC I09H .9 .7I Ii al aal I I I C ITEHITEH islAco45 IA-580-M/ULC IVS1 -.8 Ii al 31I I I I C ITEHITEH PSIAC045 IA-580-M/ULC Ivsi .9 .5I IP al aol I 94I 64I C ITEHITEH PSIAC052 IA-580 M/ULC Ivsa .9 1.1I II al 32I I I I C ITEHITEH PSIAC052 IA-580 M/ULC Ivs3 .9 Ii al aal I 47I ssl C ITEHITEH sclAcoo3 IA 580.M/ULC lvs3 -.9 .9I Ir al aal C ITEHITEH PSIAC039 IA-580.M/ULC lvsa -.9 IP al aal I I I C ITEHITEH PSIAC039 IA-580.M/ULC Ivs4 -.9 ~ 9l IP al aal I 34I sel C ITEHITEH PCIAC004 IA-580 M/ULC IDHB .0 Ii al aal I eel sel C ITEHITEH PSIAC032 IA-SBO.M/ULC lvsa -.9 .7I li al 23I I 35I 69I C ITEHITEH PCIAC003 IA-580.M/ULC IDCB .0 1.5I Ii al ael I I I 37I 69I C ITEHITEH PSIAC003 IA-580-M/ULC IDHB - 3 .Sl IP al aol I I I I I I I C ITEHITEH PSIAC003 IA-580-M/ULC I07c 25.o a.ol IP al 32I I I I I 42I rol C ITEHITEH GNPLIAC060 IA-580-M/ULC IDCB ~ 7 1.11 IP al 36I I I I I 44I rol C ITEHITEH PSIAcoso IA-580 M/ULC Iocg ~ 0 .5I IP al 24I I 82I 7ol C ITEHITEH PSIAC032 IA-580.M/ULC Ivs3 -1.0 .7I I eel rol C ITEHITEH PSIAC032 IA-580-M/ULC Ivsa - 7 .sl IP al aal I136I rol C ITEHITEH PSIAC IA-580 M/ULC IVS1 -.8 1.1I Ii al ael I I I C ITEHITEH PSIAC045 IA-SBD.M/ULc Ivs3 - 7 .sl Ii al aol I 39I 71 I C ITEHITEH PSIAC069 IA-580-M/ULC IDCB .0 .sl li al aol I 41I 71I C ITEHITEH PSIAC069 IA-seo-M/ULC IDCB .0 Ii al aol I 43I 71 I C ITEHITEH PSIAC069 IA-580-M/ULC IDCB .0 .7I Ii al 21I I 45I 71I C ITEHITEH PSIAC069 IA-580-M/ULC I DC 8 .0 .9I Ii al 23I I I I C ITEHITEH PSIAC069 IA-580-M/ULC IDCB ~ 0 79I 71I C ITEHITEH PSIAC039 IA-580 M/ULC IVS2 - 7 ~ 7I IP al aol I

I 38I ral C ITEHITEH GYPLIAC060 IA-580 M/ULC IDHB ~ 0 .Sl li al 31I I I I C ITEHITEH PSIAC060 IA-580 M/ULC IDCB 1.0 .7I IP al arl I 40I ral C ITEHITEH PLIAC060 IA-580 M/ULC IDHB .0 1.ol li al 33I

'---I-- I- --I--I------ -I- I I I I

IND I CAT IOHS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  : STG O'A Page 3 DESCRIPTION : 20K TO 100K Date : 11/16/95 Time : 08:38:56 I (

Extent I 10/95 I I N/A (Row( Lin(LeglReqlTst/ Note( Reel Probe Location (volts(oeg(ch X (D i ff Location lvoitsloeg(ch I X I

+- I I I

-I- I

( (

-- --------I----I. I--I" +

I I I C ITEHITEH GNPLIAC060 IA-580-M/ULC (DCT .0 IP 2( 3s(

I 42( 72( C ITEHITEH GNPLIAC060 IA-580-M/ULC IDHB ~ 0 1.11 IP 2( 36(

I I I c ITEHITEH IAC060 IA-580.M/ULC IDCT .0 (I 2( 24(

I 82( 21 C ITEHITEH PSIAC032 IA-580-M/ULC IVS3 -.8 (I 2( 22(

( 88( 721 C ITEHITEH PSIAC032 IA-580-M/ULC Ivs3 1.0 ~ 7( (I 2( 221 (126( 721 c ITEHITEH PCIAC042 IA-580-M/ULC 109H ~ 1 .411331 1( 24(

721 C ITEHITEH PSIAC045 IA-580-M/ULC IVS1 .8 .6( (I 2( ao(

( 43( 731 C ITEHITEH PSIAC069 (A-580-M/ULC IDHT .0 .6( (p 2( ao(

I I I C ITEHITEH PSIAC069 IA-580-M/ULC (Dce ~ 0 .61 IP 2( ao(

( 491 731 C ITEHITEH PSIAC069 (A-580.M/ULC (Bee .0 ~ 71 IP 2( as)

I 55( 73( C ITEH(TEH PSIAC069 IA-580-M/ULC IDCB .0 (I 2( ao(

175( 73( C ITEHITEH PSIAC039 IA-580-M/ULC (VS3 ~ 9 .9( (I 2( 22(

11351 731 c ITEHITEH PSIAC045 IA-580-M/ULC (VS1 .8 (I 2( 28(

I I ( C (TEH(TEH PSIAC045 IA-580-M/ULC IVS3 .9 .61 IP 2( 21(

I I I c ITEHITEH PSIAC045 IA-580-M/ULC Ivs4 -.9 .91 (I 2( 26(

( 421 74( c ITEHITEH GYPLIAC060 IA-580-M/ULC IDHB .0 2.61 (I 2( s3(

I C ITEHITEH PSIAC060 IA-580-M/ULC IDCB .0 (P 2( 311 741 C ITEHITEH PSIAC032 IA-580-M/ULC (vsa - ~8 1.21 (I 2( 311

( 43( I C ITEHITEH PCIAC069 IA-580-M/ULC IDHB .0 (I 2( 321 I I I c ITEHITEH PCIAC069 IA-580-M/ULC IDCT .0 2.3 ( (I 2( 34(

I 451 75( C (TEHITEH PLIAC069 IA-580-M/ULC IDHT .0 1.21 I I as(

I I I C ITEHITEH PSIAC069 IA-580.M/ULC IDCT .0 ~ 91 Ii 2( 23(

751 C ITEHITEH PSIAC045 IA-580 M/ULC IVS1 .9 ~ 61 (I 2( 21(

I 441 761 c ITEHITEH GNPL(AC060 IA-580-M/ULC IDHB .0 1.2( (I 2( 37(

771 c ITEHITEH PSIAC069 IA-580 M/ULc IDGT .0 a.o( IP 2( 32(

( S1( 77( C ITEHITEH PSIAC069 IA 80 M/ULC I CT .0 2.11 (I 2( 33(

I 531 77( C (TEH(TEH PSIAC069 IA-580-M/ULC IDHB .0 1.61 (I 2( 3o(

I I I C ITEN(TEH PSIAC069 IA-580-M/ULC IDCT ~ 0 .8( IP 2( 22(

1571 77( C (TEH(TEH PSIAC069 IA-580-M/ULC IDCT .0 1.o( II 2( 241

( 73( 771 C ITEHITEH PSIAC039 IA-580-M/ULC IVS2 -.7 (I 2( 211 I I I C ITEHITEH PSIAC039 IA-580.M/ULC IVS2 .8 1.01 (p 2( 22(

( so( 781 C ITEHITEH GNPLIAC060 IA-580-M/ULC IDHB .0 1.11 IP al 3s(

( 72( 781 C ITEHITEH SSIAC038 IA-580.M/ULC IVS4 -.5 II 2( 3o(

( 961 781 C ITEHITEH Ps(Aco61 IA 80 M/ULC IVS3 -.9 ~ 9( (I 2( as(

I 49( 791 C ITEHITEH PS(AC069 IA-580 M/ULC IDHT .0 (I 2( 29(

I I I C (TEH(TEH PS(AC069 IA 580 M/ULC IV 3 -.9 2.21 II 21331 c ITEHITEH PS(AC069 (A-580.M/ULC (VS3 - 2 F 81 II 2( 22(

I I I I I I C ITEHITEH PSIAC069 IA-580-M/ULC IDCT ~ 0 1.S( II 2( 291

( S3( 79( C ITEHITEH PS(AC069 IA-580.M/ULC IDHT .0 .71 ,,

IP 21 211 791 C ITEHITEH PSIAC069 (A-580-M/ULC (DCB .0 1.21 Ii a( 261 I sa( 8O( C (TEH(TEH GHPL(AC062 IA-580-M/ULC IDHT .0 1.71 (P 21 4s(

I I I C ITEHITEH GYPLIAC062 IA-580-M/ULC IDCB .0 1.7( (p 2( 46(

S4( 801 C ITEHITEH PSIAC062 (A-580-M/ULC (DCT .0 IP 21 261 I---I- '

( I I I I I

+---(- --I --I- I I -I ---------I- I -I -

I

--I----I- I

INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  : STG IIA Page 4 DESCRIPTION : 20/. To 100K Date : 11/16/95 Time : 08:38:56 I I Extent I I 10/95 I I N/A I IRoM) Lin)Leg)Req)Tst/ Note( Reel Probe )

Lo ca'tion )Volts)oeg)ch )

X )Diff) Location )volts)oeg)ch )

x I

+- I I I I- I

.-I- . .- "---I----.I---I I- -I----I--- --------I-----I ---)---+

I 62) 801 C ITEHITEH GNPLIAC062 IA-SBO.M/ULC IDCB ~ o I -9) I>>I 34) I I I 4 81) C ITEH)TEH PSIAC071 )A-580-H/ULC )OHB .0 )I 2) 21)

I I )

C )TEH)TEH PL)AC071 IA 580-H/ULC )VS3 -.8 1.81 Ii 2) 3o) I I I I c ITEHITEH PLIAC071 IA-580-H/ULc IDGT .0 2.71 Ii 21 361 I I s3) 811 C ITEHITEH PSIAC071 IA.580-M/ULC )oHB .0 1.o) Ii 21 22) I I I I c ITEH)TEH PSIAC071 IA-seo-M/ULC IDGT .0 1.s) II 2) ar) I I ss) 811 C ITEHITEH PSIAC071 IA-580-H/ULC IDCT .0 2.11 IP 2) 32) I I 73) e1) c )TEH)TEH IAC041 IA-580-H/ULC 103C -.6 .411361 11 251 I I 501 821 C ITEHITEH PSIAC062 IA-580-M/ULC IDCB ~ 0 )p 2) 27) I

) 6o) 821 c ITEHITEH PCIAC062 IA-580-H/ULC IDHB, .0 IP 2) 28) I

) 541 841 C ITEHITEH PSIAC058 IA-580-M/ULC IDCT ~ 0 ~ 91 )I 21 341 I I 49) 851 c ITEHITEH PSIAC067 IA-580-M/ULC IDHB .0 1.7) )p 2) 3o) I' I I I C ITEHITEH GNPLIAC067 IA-580-M/ULC IDCB .0 2.7) )I 2) 371

) S1) 851 c ITEHITEH PSIAC067 IA-580-M/ULC IDHB .0 1.11 )I 2) 24) I I I I c ITEHITEH PSIAC067 )A-580-M/ULC )DCB .0 1 ~ O) Ii 21241 I I ss) 851 C ITEHITEH PSIAC067 IA-580 M/ULc IDCB ~ 0 2.11 )P 21 33)

~ / 57/ 851

) 56) 861 861 C

C ITEKITEH 851 c ITEHITEK I 541 861 C ITEHITEH C ITEHITEK PSIAC067 PSIAC041 ITEHITEH GYPLIAC058 PCIAC058

-PSIAC058 IA-580-M/ULC IA-580-H/ULC IA-580-M/ULC IA-580.M/ULC IA-580 H/ULC IDCB IVS4 IDHB IVS3 IDCB

.0

-1.0

~ 1

-1.0

~ 0

.4) 1.51

.S)

.8)

I>>I

)I

)I Ir

)I 2) 2)

2) 2)

261 ao) 43) as) 3o)

I

) se) 861 C ITEHITEH PSIAC058 IA-580.M/ULC IDCB .0 .61 )r 2)as)

) 92) 861 C ITEHITEK PSIAC061 IA.580-M/ULC IVS2 .7 .8) )I 2) 23)

I I I c ITEHITEK PSIAC061 IA-580-H/ULC IVS3 -.7 1.61 II 2) 32)

I I I c ITEHITEK PSIAC061 IA-580-H/ULC IVS4 -.9 .61 )I 2) 21)

)14o) 861 C ITEHITEH PSIAC045 IA-580-H/ULc IDGT .0 1 '1 )p 2)'34)

I 491 871 C ITEHITEH PLIAC067 IA-580.H/ULC IDCT .0 2.51 )I 2) 36)

) S1) 871 C ITEHITEH PSIAC067 IA-580-H/ULC IDHB .0 )

'.1) Ir 2) as)

I I I c ITEHITEH PSIAC067 IA-580.H/ULC IDCT .0 IP 21 321

) SS) 87) C ITEH)TEH PSIAC067 IA-580-H/ULC IDHB .0 1.2) )I 21 as)

I I I c ITEKITEH PSIAC067 IA-580-H/ULC IVS3 .8 .7) )I 2)ao)

I I I c ITEHITEH PSIAC067 )A-580-H/ULc IDGT .0 1 ~ 11 II 21 as)

) s91 871 c ITEHITEH PSIAC067 IA-580-M/ULc IDHB .0 .8) )I 21 as/

I 931 e71 c )TEH)TEH PS)AC IA-580-H/ULC IVS2 .8 .S) )I 2) 221

) so) 881 C ITEHITEH Ps)Acose )A-SBO-H/ULC )OCB .0 )p 2) as)

I 941 88) C ITEHITEH PC)AC )A-580.H/ULC )VS4 -.9 .S) )p 2) 21)

I 47) 891 C ITEHITEH GYPLIAC067 )A-580.H/ULC )DHB ~ 0 )P 21 48)

) S3) 891 C ITEHITEH PSIAC067 IA-580 M/ULC IDHB .0 )p 2) as/

I I I c ITEHITEH PSIAC067 IA-580-H/ULc IDGT .0 .71 Ir 2) ao)

) 951 891 C ITEHITEH PLIAC061 IA-580-H/ULC IVS4 1.2 .61 IP 2) as/

I 451 911 c ITEHITEH PSIAC067 IA-580-H/ULC IDHB .0 1.31 Ir 2) 261 I I I C ITEHITEH PSIAC067 IA-580-H/ULC IDCT .0 1.31 IP a) as/

471 911 C )TEH)TEH PSIAC067 IA-580-H/ULC IDHB .0 .7) II 21 ao)

--I- '

) I I I I I

+---I---I---I- I I

-I---'---------I- I

-I---I---I---I- -I- ---I I

INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  : STG fIA Page ~

5 DESCRIPTION : 20K TO 100/e Date : 11/16/95 Time : 08:38:56 I I Extent I 10/95 I N/A I IRowlLinlLeglReqlTst/ Hotel Reel- Probe I Location lvoltslDeglch I x IDiffl Location lvoltsloeglCh I x I

'---I---I---I- I---- ---I -I-----I---I--I---I-- +

1139l 91I C ITEHITEH PSIAC045 IA 80 H/ULC IDHT .0 I 1.al II al asl I I 45I 93I C ITEHITEH PSIAC067 IA-580.M/ULC IDCB .0 ~ rl aol I I 97I 93I C ITEHITEH PSIAC056 IA-580-H/ULC IVS3 .9 .4I lp al 22I I 49I 9sl C ITEHITEH PLIAC067 IA-SSO.H/ULC IVS3 - 7 II al 26I I I I I I C ITEHITEH PSIAC067 IA-580 M/ULC IDCT ~ 0 1.2I II al asl I I 94I 96I C ITEHITEH PBIAc056 IA-580-M/ULC IVS2 ~ ? .5I Ip al 26I I I 4rl 9rl C ITEHITEH PLIAC067 IA-SBO.H/ULc Ivs3 .8 lp al 26I I I I I C ITEHITEH PBIAC067 IA-580 M/ULC IDCB .0 .Sl Ir al 21 I I I s3I 9?l C ITEHITEH IAC067 IA-580-M/ULc I04c 26.2 .SI134I 29I I I13sl 9?l C ITEHITEH IslAco45 IA-580.H/ULc IVS3 .8 .6I 21 I I I134I 98I C ITEHITEH PCIAC045 IA-580.H/ULC IVS3 - 3 .sl I>>l aol I I138I 98I C ITEHITEH IslAco45 IA-580-H/ULC IDHT .0 1.6I Ir al I H ITECITEC PSIAH082 IA-580.M/ULC IDCB ~ 0 I>>l 22I I I 45I 99I H ITECITEC PSIAH082 IA-580-H/ULC IV 3 .8 II al 22I I I 4ol1ool H ITECITEC PCIAH105 IA-580.H/ULC IVS3 -.8 .sl II al 21 I I 46I100I H ITECITEC PSIAH105 IA-580-M/ULC IVS3 - 7 .Sl II al 24I I I I 48I100I H ITECITEC PCIAH105 IA-580.H/ULC IDCB .~ 0 .6I II al 22I I I 54I1ool H ITECITEC PCIAH107 IA-580-H/ULC IVS3 ~ 7 .6I I>>I 26I I I 31I1oil C ITEHITEH PCIAC030 IA-580-H/ULc IDGT I>>l I I 34I102I H ITECITEC PCIAH105 IA-580-M/ULC IVS3 .8 .sl lp al 21 I I I134I1oal C ITEHITEH PCIAC045 IA-580-H/ULC IDCT .0 I>>l as/ I I 91I1o3I C ITEHITEH PLIAC069 IA-580-H/ULC IVS4 ~ 9 .Sl lp al 22I I I 95I105I C ITEHITEH PCIAC063 IA-580-H/ULC IVS3 ~9 .6I II al 21 I I I I I 96I108I C ITEHITEH PSIAC024 IA-580-H/ULC IVS2 -.9 .5I II al I I I I I I C ITEHITEH PSIAC024 IA-580-H/ULC IVS3" -.9 .7I I>>I arl I I I I 101 I 109 I C ITEHITEH PSIAC023 IA-580-H/ULC IVS3 1.0 .sl I>>I 21 I I I I I aal11ol C ITEHITEH SCIAC029 IA-580-H/ULC I03C 12.5 I I 123 I 113 I C ITEHITEH PSIAC018 IA-580.M/ULC IVS1 -.8 .4I Ip al aol I I I I C ITEHITEH IAC018 IA-580.H/ULC IVS3 ~ 7 I>>l aol I I I I C ITEHITEH PSIAC018 IA-SSO.H/ULC IVS4 -.9 .6I II al 22I I I 4?I11sl H ITECITEC PSIAH084 IA-580 H/ULC IVS -.8 .7I I>>l 23I I I I I H ITECITEC PSIAH084 IA-580-H/ULC IVS3 1.0 .sl I>>I aol I I127I117I C ITEHITEH PSIAC023 IA-580-M/ULC IVS1 .8 .6I lp al 22I I I 84I12ol C ITEHITEH PSIAC015 IA-580-M/ULC IVS4 .9 .6I II al 21 I I I 94I12ol C ITEHITEH PSIAC023 IA-580-M/ULC lvsa .8 II al 26I I1oal12ol C ITEHITEH PSIAC017 IA-580-M/ULC lvs3 -.8 .sl II al aol I126I12ol C ITEHITEH PCIAC035 IA-580-M/ULC IOSH -1.3 1.ol II al aol C ITEHITEH IAC017 IA-580-H/ULC lose .8 .6I II al aal I s3I12rl c ITEHITEH PSIAC012 IA-580-M/ULC IVS3 .8 .Sl li al arl I 91I12?l C ITEHITEH PCIAC018 IA-580-M/ULC lvsa -.9 .5I II al as/ I I 9?I12?l C ITEHITEH Ps IAC017 IA.580-H/ULC Ivs3 .8 .7I II al 24I I I s4I128I C ITEHITEH PSIAC011 IA-580-H/ULC IVS3 .8 .6I II al aal I I 8?I129I C ITEHITEH SCIAC016 IA 58 H/ULc Ivs3 -.8 I ~ 4I Ip al aol I I I---I---I---I-- ----I- I- I


I- I I I I-

INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  : STG ¹A page : 6 DESCRIPTION: 20K TO 100K Date : 11/16/95 Time : 08:38:56 I I Extent IRoMILin(Leg(ReqlTst/Note( Reel Probe I '0/95 Location lvolts(Deglch I I I Location N/A lvoltslDeglch X

+

I

--I--I- I- -I--I--I- (Diff(

I I I I I I I I I

---I---+

I I I c ITEHITEH PSIAC016 IA-580 M/ULC lvs3 I 1 41 IP 2( 36( I I I I 9311311 C ITEHITEH PSIAC023 IA-580.M/ULC IVS2 .9 I -91 IP 21 26( I I I I 5711331 C ITEHITEH Is Iacoiz IA-580-M/ULC IVS3 -.6 .6( IP 21 24( I I I I 9711331 C ITEHITEH Ps IAC014 IA-580 M/ULC lvsz I .71 IP 21 27( I I I I 9611341 c ITEHITEH Ps IAC013 IA-580.M/ULC lvsz .8 I ~ 4( IP 2( 20( I I I I I I c ITEHITEH Ps IAC013 IA-580.M/ULC lvs3 .7 I F 51 IP 2( 21( I I I

( 96('138( C ITEHITEH PS IAC013 IA-580.M/ULc lvsz .6( li 21 zzl I I I I I I c ITEHITEH Ps IAC013 (A-580 M/ULC lvs3 I 1 1( IP 2( 27( I I I I 9 11391 C ITEHITEH Ps IAC014 IA-580.M/ULC (VS2 I ~ 4( IP 2( 21( I I I I 97(1391 c ITEHITEH PSIAC013 (A-580-M/ULC IVS2 -1.2 as( IP 2( 24( I I I I 481140( C ITEHITEH PSIAC009 IA-580.M/ULC IVS3 .8 .sl Ip 21 22( I I I I 111411 c ITEHITEH PCIAC033 IA-560-SF/RM (01H 24 ' I 7(142( 1( 20( I I I I 85(141( c ITEHITEH PSIAC013 IA-580 M/ULC IVS3 .8 6( Ip zl 21( I I I I 8711431 c ITEHITEH IAC014 IA-580.M/ULC IVS2 -1 ~ 1 4( IP 2( 211 I ( I I I I I I c ITEHITEH PCIAC014 IA-580-M/ULC IVS3 .4 I sl IP 2( 24( I I I I 4911471 c ITEHITEK PSIAC012 IA-580-M/ULC IDCB .O I .6( II 21 zzl I I I I I I 5611521 C ITEHITEH PSIAC014 (A-580-M/ULC I vs3 -1 ~ 0 I li 21 22( I I I I I 7411541 C ITEHITEH PSIAC013 IA-580.M/ULC 105H 26.1 I .511331 11 301 I I I I I 5711551 c ITEHITEH PSIAC013 IA-580-M/ULC IVS3 -.7 .6( Ip 2( z1( I I I .I

( 51(157( C ITEHITEH PSIAC014 (a-580-M/ULC lvs3 (I 2( 28( I I I I I 311591 C ITEHITEH PSIAC033 IA-560 SF/RM 103c 5.8 I .511281 11 351 I I I I

+ I I I I I I I


I----.I---I- -I- -I----

Number of RECORDS, Selected from C urrent Outage 236 Number of TUBES Selected from Cur rent Outage : 177

lND I CAT IONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  :~ STG ffe Page : 1 DESCRiPTION : 20K TO 100K~ Date : 11/16/95 Tine : 08:40:03 I I Extent I I 10/95 I I N/A I IRo~l LinlLeglReqlTst/Notel Reel Probe I Location I Volts l Deglch I I Ioiffl Location IVoltslDeglch I x, I

+- I I

--I- I------- I- I

-I---- I I I -I I 54l 22I C ITEHITEH PCIBC092 IA-580-M/ULC IVS3 li al ael I Brl 23I H IIECIIEC i SIBH1os IA-580-M/ULC IVS2 .7 .7I Ii al zol I 96l 24I H ITECITEC PSIBH103 IA.580.M/ULC I07H ~ 2 lr al asl I I H IIEGITEC i sleH1os IA-580-H/ULC IOBH Ii zl 21I I I H ITECITEG PSIBH103 IA-580-M/ULC IVS4 -.9 1.1I lr al asl I I H ITECITEC PCIBH103 IA 80 H/ULC IDCB .0 Ii zl zsl I 4sl 25I c ITEHITEH PSIBC105 IA-580-M/ULC IVS3 -.6 .6I lr al as/

I 94I 26I H ITEGITEC PCIBH086 IA-580-H/ULC IV 2 .sl Ii zl aol I 96I 26I H ITECITEC PSIBH103 IA-580-H/ULC IVS4 -.8 .9I Ii al 21I I 98I 26I H ITECITEC PSIBH086 IA-580-M/ULC IDCT .0 Ii zl 29I I1oil 27I C ITEGITEH IBC106 IA-580-H/ULC IDCT .0 .7I lr zl 24I Iiool 28I C ITEHIIEH PSIBC096 IA-580-M/ULC IDCT IP al 34I I >>I 29I C ITEHITEH PCIBC096 IA-580-M/ULC IDCT ~ 0 .3I lr al asl I >>I 29I C ITEHITEH PCIBC096 IA-580-M/ULC IDHB .0 .3I Ir zl asl I I I C ITEKITEH PCIBC096 IA-580-M/ULC IVS1 - 7 Ir zl 26I I I I c ITEHITEH PCIBC096 IA-580-M/ULC IVS1 .8 .2I IP al zil I I I c ITEHITEH PCIBC096 IA-580-M/ULC IVS2 1.0 ~ 4I Ir al arl I c ITEHIIEH PCIBC096 IA-580-M/ULC IVS3 -.9 ~ 2I Ir al 21I I C ITEHITEH G NPLIBC096 IA-580-M/ULC IVS3 1.0 Ir al 36I I c ITEHITEH PCIBC096 IA-580-M/ULC IVS4 .9 ~ sl IP zl as/

I I I C ITEHITEH PCIBC096 IA 580 H/ULC IV 4 -1.0 ~ sl IP al asl I 471 33I C ITEHIIEH IBC107 IA-580-M/ULC I02C 32.9 1.ol 14ol 1I zil 96I 34I C ITEHITEH PSIBC098 IA 580 M/ULC IV 2 - 7 .5I lr zl z6I I

I 81I 41I C ITEHITEH PSIBC109 IA-580.H/ULc Ivs3 -.8 .6I lr al asl I>>I 41I C ITEHITEH PCIBC127 IA-560-SF/RM IVS2 1.0 IP al zil I I I C ITEHITEH PCIBC127 IA-560-SF/RH IVS4 -1.0 lr zl azl I >>I 41I C ITEHITEH PCIBC098 IA-580.H/ULC IVS2 .7 ~ 4I lr zl 24I I I I C ITEHITEH PCIBC098 IA-580.M/ULC IVS4 -.5 ~ 4I lr zl 24I I 43I 47I C ITEHITEH PSIBC101 IA-580-M/ULC IVS3 -1.0 .6I Ir zl zal I I I 68I 50I c ITEHITEH PSIBC019 IA-580-H/ULC IVS3 -1.1 .6I IP zl as/ I

'I I srl 51I C ITEHITEH PSIBC018 IA-580.H/ULC IVS3 -.9 1.ol IP al sal I I 55I c IIEHIIEH SCIBC081 IA-seo-H/ULc Ioce .0 .Bl IP al z4I I I I1sol 56I C ITEHITEH PslecO64 IA-580.M/ULC IDCT .0 IP al sel I I Iiszl 58I C ITEHITEH PslecO64 IA-580 M/ULC IVS1 -.8 .7I lr al 29I IA-SBO.H/ULC IVS3 - 7 .rl zl 24I I 49I 59I C ITEHITEH PSIBC017 IP 59I C ITEHITEH PGIBc077 IA-580.H/ULC IDCT .0 1.01 IP zl sol I 59I 65I c ITEHITEH IBC019 IA-580.H/ULC I06H 18.3 .Bl 138I 1I 24I I137I 67I C ITEHITEH PCIBC075 IA-580-H/ULC IDHT .0 .7I IP al aol I 34l 68I C ITEHITEH PSIBC018 IA-580-M/ULC IDCT .0 1.ol IP al 31I I I I c ITEHITEH G NPLIBC018 IA-580-H/ULC IDCB .0 Ir al 36I I 36I 68I C ITEHITEH PSIBC018 IA-580-H/ULC IVS3 .9 IP zl arl I 39I 69I C ITEHITEH PSIBC019 IA-580-H/ULC I

IVS3 -.9 .5I lr zl asl 70I C ITEHITEH PSIBC082 IA 580.H/ULC IVS3 -.8 1.1I IP zl 31I

+-.-I"-I.--I- I

-I------------I-

0 INDICATIONS/TRENDING REPORT PSL-2 OUTAGE  : 10/95 COMPONENT  : STG IIB Page 2 DESCRIPTION  : 20K To 100/o Date : 11/16/95 Time : 08:40:06 I (

Extent I I 10/95 I I (Row(LIn( Leg(Req(Tst/ Note( Reel Probe ( Location (Volts(Deg(ch I X (Diff( Location (Volts(Deg(ch I X (

+ I I I I

-I- I -I ----I ---I I--.I-- I

--I-4s( ro( C ITEHITEH Is(ecosa IA-580.H/ULC IVS3 - 7 -4( IP 2( 201

( I I (35( 71( C ITEHITEH I C(BCO93 (A-580-H/ULC (DCB .5( 2( 23(

I I I C ITEHITEH Pc(BC093 IA-580-H/ULC IDCB .0 .5( 2( 23(

I 451 711 C ITEHITEH I c(ecO93 IA-580-H/ULC IDCT .0 al as(

(97( r1( C ITEHITEH ps(ec074 IA-580-M/ULC IVS4 -.9 .8( 2( 3o(

I 4s( ra( C ITEHITEH PLIBCOB IA-580-H/ULC IVS3 -.9 .5( 21 211 I 44( 76( C ITEHITEH PLIBC082 IA 580-H/ULC IDHB .0 1.2( 2( 32(

I 521 761 C ITEHITEH PLIBC082 IA-580-M/ULC IVS3 .6 IP 2( as( I I 56( r6( C ITEHITEH PL(BC082 (A-580.H/ULC IVS3 1.0 2( 22( I I 47( 77( C ITEHITEH PSIBC093 IA-580 H/ULc IDHB .0 .6( 2( 24( I

( 55( 77( C ITEHITEH PSIBC093 IA-SBO.H/ULC IDCB .0 .9( 2( 3o( I I 44( rs( C ITEHITEH PSIBC082 (A-580-M/ULC IDHB 1.3 .9( 2( as( I C ITEHITEH ps(ecosa IA-580.H/ULC IDCT - 7 .8( 21 251 I I I I I I I C ITEHITEH PL(ecosa IA-580-H/ULC IDCB .0 ~ rl 2( 24( I 46( rs( C ITEHITEH GNPLIBC082 IA-580-M/ULC IVS3 - 7 1.8( 2( 39(

I I I I I I I C ITEHITEH GNPLIBC082 PSIBC082 IA-580-H/ULC IA-580-H/ULC IVS3 1.0 2( 35( I I, I I I I C ITEHITEH IDCB ~ 5( 2( 21( I I I I 48( 78( C ITEHITEH PSIBC082 IA-580-M/ULC IDCB 1.0 2( 34(

I 50( 78( C ITEHITEH PSIBC082 IA-580-M/ULC IDHB .7 .8( IP 2( 26(

I I I C ITEH(TEH GNPLIBC082 IA-580-M/ULC IDCT -.6 1.8( 2( 39(

( 52( 78( C ITEH(TEH Is(ecosa IA-580-M/ULC IVS3 -.6 IP 2( 31(

I,88( I I C ITEHITEH 78( c ITEN(TEN Ps(scosa PLIBC054 IA-580-M/ULC IA-580-M/ULC IDCT IVS2

-.6

.7

.6(

.8(

2( 23(

24(

I (I 2(

I 96( rs( C ITEH(TEH PSIBC087 (A-580.M/ULC IVS2 -.8 .9( 2( as(

I 51( 79( C ITEHITEH PSIBC093 IA-SBO.M/ULC (Dce .0 .6( 2( 23(

( 57( 79( C (TEHITEH GMPLIBC093 IA-580.H/ULC IDCT .0 1.9( 2( 45(

I sa( so( C ITEH(TEH PLIBC082 IA-580 M/ULC IDHB ~ 8 1.5( 2( 36(

I I I C ITEHITEH PSIBC082 IA-580.H/ULC (DCT -.6 .6( 2( as/

I 49( 81( C ITEKITEH GHPL(BC093 IA-580-H/ULC IDHT -.2 2( 33(

I I I C ITEHITEH PSIBC093 IA-580 H/ULc Ioce .0 .6( 2( 24(

I 98( 82( C ITEHITEH PCIBC076 IA-580.H/ULC IVS3 1.0 4( 2( 23( -I--'/A I 49( 83( C ITEHITEH PBIBC093 IA-SBO.H/ULC IDHT .0 2( 34(

I I I C ITEKITEH PSIBC093 IA 8 H/ULC IDCT .0 .8( 2( 29(

I 51( 83( C ITEHITEH PCIBC093 IA-580-4/ULc IDGB .0 41 IP 2( ao(

I 691 831 C ITEHITEH PLIBC067 IA-580.M/ULC ITSH .6 1.411221 I 71( 83( C ITEHITEH PSIBC067 IA 80 M/ULC ITSH 1.3 ~ 411411 1( 23(

( 73( 83( C ITEHITEH Ps(ecO67 (A-580-M/ULC ITSH .7 .811371 1( as(

sr( 83( C ITEHITEH ps(eco67 IA-580 H/ULC IVS3 - 9 ~ 41 IP 2( ao(

I I 891 831 C ITEHITEH PSIBC067 IA-SBO.F/ULC Ivs3 .9 1.o( 21 321 I 48( 84( C ITEHITEH Pclecoeo IA-580-M/ULC IDCT .0 .91 IP 2( 32(

( So( 84( C ITEHITEH PSIBC080 (A-580-M/ULC (DGT .0 1.O( 2( 33(

( 88( 84( C ITEHITEH ps(ecO54 IA-580.H/ULC IVS2 .0 .8( al 241 I I 511 851 C ITEHITEH GNPLIBC091 IA-580.H/ULC IDCB .0 2.2( 1( 4s(

'.l---l -I- I I -I - ------I I I---I I----I-I I

I I

+(

0

INDICATIONS/TRENDING REPORT

~

j COMPONENT  : STG ge OUTAGE PSL-2

10/95 page 3 DESCRIPTION : 20K To 100K Date : 11/16/95 Time : 08:40:06 I I Extent I 10/95 I I N/A (RoN] tin]Leg]Req]Tst/ Note) Reel Probe I Lo cation (Volts]Deg]Ch ] X ]Diff] Location ]Volts]oeg]ch I X ]

+ I I I I

-I- I -I

] sr] ssl C ITEHITEH PSIBC091 IA-580-M/ULC IDCB .0 .sl ]I z] 24]

] 46] S6] C ITEN(TEH Pslecoso IA 8 M/ULC IDCT .0 1.O( ]I 2] 33]

I I I C ITEHITEH PS]BCOSO IA-580 M/ULC IDCB .0 .sl Ip 2] zol I 54] s6] C ITEHITEH Pc]BCOSO IA-580 M/ULC IDCT .0 .S] Ii z] Zl]

] ss] 86] C ITEHITEH PSIBC056 IA-580.M/ULC IVS3 .7 ~ 6] ]I z] 24]

] 47] sr] C ITEH]TEH PCIBC091 IA 8 M/ULC IDHT .0 ~ 9( ]I 2]

I 55I 87I C ITEHITEH PCIBC091 IA-580 M/ULC IDCT .0 I>>I 3Z]

] 73] sr] C ITEHITEH PSIBC067 IA-580 M/ULC ITSH 1.4 1.4 I 137 I 11 28]

I 48I BSI C ITEHITEH PSIBCOSO IA-580.M/ULC IDHB .0 l.o] Ii z] 34]

I I I C ITEHITEH PSIBCOSO IA-580 M/ULC IDCB ~ 0 sl I>>l 21 I

] sa] as/ C ITEHITEH I s]ecOSO ]A-580-M/ULC ]VS3 -.8 ~ 9] ]I 2]

] s6] ss] C ]TEH]TEH GNPLIBcoso IA-580-M/ULC IVS3 -1.0 1.4( I>>l

] 62] Ss] C ]TEH(TEH PCIBC080 IA-580-M/ULC IVS3 -.9 .7( ]I a] 2S]

I I I C ITEHITEH PCIBCOBO IA-580-M/ULC IVS3 -.9 .r] Ii zl zs] I

] 72] as( C ITEHITEH GNPL]BC056 IA-580 M/ULC ITSH 1.2 2.9I141I 1I 22I I I 51I 89I C ITEHITEH PCIBC091 ]A-580 M/ULC ]OHB . 3 .S] ]I zl z3] I I 44I 9o( C ITEHITEH GNPL]BC080 IA-580 M/ULC IDHB 1.1] I>>I 36( I I 4S( 91] C ITEHITEH GNPLIBC091 ]A-580-M/ULC ]OHT ~ 0 ]I al 39] I I I I C ITEHITEH PS]BC091 IA 580 M/ULC IV 3 -.9 .7] Ip zl zsl I I I I C ITEHITEH PSIBC091 IA-SSO.M/ULC IVS3 -.5 ]p 2] zz] I I I I C ITEHITEH PSIBC091 IA-580.M/ULC IDCT ~ 0 .S] lp zl 23( I I I I C ITEHITEH PSIBC091 IA-580.M/ULC IDCT .0 .S] (I al 23] I I I I C ITEHITEH PSIBC091 IA-580-M/ULC IDCB ~ 0 ]I 2] as/ I C ITEHITEH PSIBC058 ]A-580-M/ULC ]TSH .9 2.0]130] 1] 32( I

] 42] 92] C ITEHITEH Is(ecoso IA-580-M/ULC IDCT .0 ]p 2( z3] I

] 46] 92] C ITEHITEH GNPLIBCOSO IA-580-M/ULC IVS3 -.5 Ii 2( 3zl I s4] 92] C ITEHITEH ps]ecoso ]A-580-M/ULC Ivs3 - 7 1.O] (I zl 34]

I I I 6o] 92] C ITEHITEH PSIBCOSO IA-580-M/ULC IVS .1 ~ 1 ~ S] ]p z] zo] I

] 43] 93] C ITEHITEH PCIBC091 IA-580-M/ULC IDCB .0 4( ]I z] 22] I

] 4zl 94] C ITEHITEH ps]ecoso IA-580-M/ULC IDCB ~ 0 .9( Ii 2] 31] I I 461 94I C ITEHITEH PL]BC080 IA-580-M/ULC IVS3 -1.0 .9] Ii 2] 31( I I I I C ]TEH]TEH PSIBCOSO IA-580.M/ULC IDCB .0 .7] Ip 2] zr] I

] 50] 94] C ITEHITEH PCIBC080 IA-SSO.M/ULC IVS3 .1 ~ 1 .6] ]I z] 23] I

( sa( 94] C ITEHITEH PSIBC080 IA S M/ULC IDCB ~ 0 ~ 6] ]I 2] 22( =I I 94I 96I C ITEHITEH PSIBC078 IA-580.M/ULC IVS2 1 ~ 1 I

I 71] 97] C ITEHITEH PSIBC073 ]A-580-M/ULC ]VS4 .0 .7] ]I 2] zs] I

] 93] 97] C (TEH(TEH PSIBC078 IA-580-M/ULC,IVS2 .9 .S] ]p zl 24] I

] 34] 98( C ITEHITEH PSIBC097 IA-580 M/ULC IDHB ~0 .S] I

] 3r] 99] C ITEHITEH PLIBC084 IA-580.M/ULC IVS3 -1.0 ]I z] 32( I I 94I100I C ITEHITEH Ps]Bc078 IA-580-M/ULC IVS2 -.8 .9] ]I z] 33] I I I I C ITEHITEH PSIBC078 IA-SSO.M/ULC IVS2 .9 ]I zl 33] I I 93I101I C ITEHITEH PSIBC078 IA-580.M/ULC IVS2 ..8 .r] ]p 2] 3ol I C ITEHITEH PCIBC078 IA-580.M/ULC IVS3 ..5 .5] ]I zl 24] I I---I---. -I--------- --I-S

INDICATIONS/TRENDING REPORT PSL-2

10/95

'Uj'AGE COMPONENT  : STG ¹B Page DESCRIPTION : 20K TO 100/ Date : 11/16/95 Time : 08:40:06 I Extent 10/95 I I N/A IRoMILin(Leg(Req(Tst/Note( Reel Probe Location lvoltsloeg(ch I X (Diff( Location (volts(Deglch ( X I

'--- I--- I--- - I---'----I-I I I I


I- I---I---I----I-- ---------I-----I --I--I-- +

(13511011 C I TEH I TEH Ps I Bc075 (A-580-M/ULC Ivs1 .o I 1.11 IP 21 311 I I 1611061 c ITEHITEH PSIBC052 (A-580-M/ULC lo3c .8( IP 2( 29(

I 18(106( c ITEHITEH PSIBC053 IA-580-M/ULC 103C 1.5 IP 21 23(

I 3211061 c ITEHITEH PSIBC052 IA-580-M/ULC I vs3

..8 .5( IP 21 25(

I 50(1061 c ITEHITEH IBC097 IA-580-M/ULC Ivs3 -.9 IP 2( 22(

I 96(108( c ITEHITEH Islgco4o IA-580-M/ULC Ivs2 -.9 .91 IP 2( 3o(

I 521110( C ITEHITEH PLIBC086 (A-580-M/ULC Ivs3 .5 1.21 (r 2(35(

I 8911111 C (TEHITEH PSIBC099 IA-580-M/ULC lvs4 .7 IP 2( 26(

I 96(1141 C ITEHITEH PS(BC042 IA-580 M/ULC Ivs2 -.8 1.21 I I I C ITEHITEH Ps(Bc042 IA-580 M/ULC lvs2 .7 .5( lr 2( 22(

I I I C ITEHITEH PSIBC042 IA-580.M/ULC lvs4 ..8 lr 2( 21(

(129(115( C ITEHITEH IBC043 IA-580-M/ULC IOBH ~ 8 1.1( II 2( as/

I 52(116( C ITEHITEH PLIBC086 IA-580-M/ULC Ivs3 1.0 .5( Ii 2( 2ol I 8911171 C ITEHITEH Pslgco38 IA-580-M/ULC Ivs2 -.9 .61 lr 2( 23(

I 5111211 C ITEHITEH SSIBC048 IA-580-M/ULC Ivs3 . 7 ~ 61 II 2( 21(

I 9411241 C ITEHITEH PSIBC045 IA-580-M/ULC Ivs2 -.8 .5( II 2( 2ol I 5511251 C ITEHITEH PSIBC028 IA-580-M/ULC Ivs3 - 7 1.21 IP 2( 34(

I 6011341 C ITEHITEH PSIBC031 IA-580-M/ULC IVs3 -.9 ~ 5( (r 2( 22(

I 891135( C ITEHITEH PLIBC032 IA-580.M/ULC IDCB .0 ~ 21 (r 21 241 I 9411361 C ITEN(TEN PSIBC032 IA-580.M/ULC Ivs4 .0 .21 (r 2( 25(

I 7o(138( C ITEHITEH PLIBC041 IA-580.M/ULC Ivs3 .6 .5( lr 2( 21(

I 55(1391 C ITEHITEH PSIBC028 IA-580.M/ULc lvs3 .7 1.11 IP 2( 33(

I 92(142( C ITEHITEH PSIBC034 IA 580-M/ULC Ivs2 1 ~ 0 .8( lr 2( 221 I 9511431 C ITEHITEH PCIBC034 IA-580-M/ULC IVS2 1 0 ~ 8( (r 2( 231 I 7611461 C ITEHITEH PCIBC034 IA-580-M/ULC IVS2 1.0 .6( (r 2( 2ol I 82(15ol C ITEHITEH PSIBC035 IA-580-M/ULC Ivs3 .0 .61 I 641152( C ITEHITEH PSIBC037 IA.580-M/ULC lvs2 .o .8( IP 2( 2ol

+- I I I I-- - -I----- I I I I I I Number of RECORDS Se lected from Current Outage 156 Number of TUBES Sole cted from Cu rrent Outage : 120

St. Lucie Unit 2

~

~ ~

L-96-72 Docket No. 50-389 Fall 1995 Refueling Outage NIS-1 ATTACHMENT 3 1995 OUTAGE SNUBBER FUNCTIONAL TESTING

SUMMARY

REPORT

L i ni 2 As part of Unit 2 Refueling Outage work scope, the following, tests and other related tasks were performed:

A. Visually examined 106 of 230 mechanical and hydraulic snubbers.

B. Functionally tested 27 snubbers which failed during the previous outage.

Tag-2-019 Tag-2-093 Tag-2-146 Tag-2-178 Tag-2-243 Tag-2-039 Tag-2-094 Tag-2-156 Tag-2-183 Tag-2-315 Tag-2-041 Tag-2-096 Tag-2-157 Tag-2-185 Tag-2-316 Tag-2-066 Tag-2-102 Tag-2-169 Tag-2-241 Tag-2-322 Tag-2-067 Tag-2-120 Tag 177 Tag-2-242 Tag-2-334 Tag-2-070 Tag-2-144 C. Functionally tested 68 of 230 mechanical and hydraulic snubbers as part of the selected samples.

D. Completed activities authorized 'by Plant Change/Modification packages:

M2 2 2M; Modified 1 snubber during this outage.

Tag-1-067, (STAR-2-951523;CRN-279-292-5624)

Upgraded with a Lisega Hydraulic.

St. Lucie Unit 2 Snubber Test Results Iud t<ihria Icashn Bmulh Guuura.'~

bor: 2-002 Initial Drag: N/A SMPL-1 Activation: 0 Serial Number: 78331/11 Test Load: 240000 162647  % Load: .68 198762  % Load: .83 Mark Number SS-2-2A N/A Final Drag:

Capacity: LSG-3102 Lock up: 6.60 5.02 Pass 5.02 Pass Rplcmnt S/N Release: OA4 0.2 Pass 0.28 Pass Tag Number: 2-004 Initial Drag: N/A Test Typo SMPL-1 Activation: 0 Serial Number: 78331/12 Test Load: 240000 156542  % Load:.65 198868  % Load:.83 Mark Number SSR-2A Final Drag: N/A Capacity: LSG-3102 Lock up: 6.60 5.31 Pass 5.16 Pass Rplcmnt S/N Release: 0.44 0.16 Pass 0.04 Pass Tag Number: 2-017 Initial Drag: 800 703.1 Pass 859.5 Fail Test Type SMPL-1 Activation: 0 Serial Number: 33336-1 Test Load: 32000 37212  % Load: 1.16 37477  % Load: 1.17 Mark Number 2A1 Final Drag: 800 579.4 Pass 728.1 Pass Capacity: PMHQO Lock up: N/A Rplcmnt SIN Release: 25.00 11.35 Pass 11.21 Pass T mber: 2-019 Initial Drag: 800 552.1 Pass 358.2 Pass pe PEV.FAIL Activation: 0 Ser Number: 33486-1 Test Load: 32000 37056  % Load: 1.16 39471  % Load: 1.23 Mark Number 281 Final Drag: 800 420.8 Pass 247.8 Pass Capacity: PMHAO Lock up: N/A Rplcmnt S/N Release: 25.00 11.35 Pass 12.25 Pass Tag Number: 2-023 Initial Drag: 21 6.3 Pass 7.6 Pass Test Type SMPL-1 Activation: 0 Serial Number: 61211/61 Test Load: 540 550.3  % Load: 1.02 560  % Load: 1.04 Mark Number RC-44-R7 21 7.6 P.ass 9.3 Pass Final Drag:

Capacity: LSG-3018 Lock up: 14.17 10.20 Pass 8.35 Pass Rplcmnt S/N Release: 4.72 2.58 Pass 1.53 Pass Tag Number: 2-024 Initial Drag: 21 8.9 Pass 12.7 Pass Test Type SMPL-1 Activation: 0 Serial Number: 61211/66 Test Load: 540 555.2  % Load: 1.03 564.4  % Load: 1.05 Mark Number RC-44-R7 21 9.4 Pass 12.4 Pass Final Drag:

Capacity: LSG-3018 Lock up: 14.17 10.05 Pass 8.42 Pass Rplcmnt S/N Release: 4.72 2.41 Pass 2.51 Pass Tag Number: 2-037 Initial Drag: 7500 78.5 Pass 56.9 Pass Test Type SMPL-1 Activation: .02 .013 Pass .008 Pass S umber: 12504 Test Load: 12000 12389.3 Load: 1.03 11279.2  % Load: .94 mber SIR205-4080 Final Drag: 7500 31 Pass 24.7 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results IcsiSrihxia Xemxl Ecaulfs Camarade~ Brudh 2-038 Initial Drag: 75 22.3 ber:

T pe SMPL-2 Activation: .02 .019 Pass .008 Pass Serial Number: 19221 Test Load: 1200 1281.1  % Load: 1.07 1281.9  % Load: 1.07 Mark Number CH-103-R10A Final Drag: 75 18.8 Pass 26.3 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-039 Initial Drag: 17.5 13.8 Pass 23.3 Fail Tag Number:

Test Type PEV.FAIL Activation: .02 .01 Pass .015 Pass Serial Number: 38503 Test Load: 280 274.9  % Load: .98 254.5  % Load: .91 Mark Number- SI-83-R3 Final Drag: 17.5 16.4 Pass 17.5 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N 38503 Release: N/A 2-040 Initial Drag: 17.5 3.9 Pass 3.4 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .01 Pass .01 Pass Serial Number: 29179 Test Load: 280 267.5  % Load: .96 300.1  % Load: 1.07 Mark Number MSI-9-R88 Final Drag: 17.5 4.5 Pass 3.7 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N Release: N/A 2-041 Initial Drag: 17.5 10.4 Pass 12.2 Pass T mber:

pe PEV.FAIL Activation: 0 Senal Number: 61211/73 Test Load: 540 571.2  % Load: 1.06 553.7  % Load: 1.03 Mark Number 8-23-R1A Final Drag: 17.5 5.9 Pass 8.3 Pass Capacity: LSG-3018 Lock up: 14.72 11.28 Pass 9.50 Pass Rplcmnt S/N Release: 4.72 2.75 Pass 2.26 Pass 2-045 Initial Drag: 21 10.8 Pass 16.3 Pass Tag Number:

Test Type SMPL-1 Activation: 0 Serial Number: 61211/55 Test Load: 540 563.  % Load: 1.04 533.1  % Load: .99 Mark Number CH-108-R4 Final Drag: 21 6.9 Pass 10.1 Pass Capacity: LSG-3018 Lock up: 14.72 10.05 Pass 8.93 Pass Rplcmnt S/N Release: 4.72 2.59 Pass 1.99 Pass 2-046 Initial Drag: 17.5 5 Pass 5 Pass Tag Number:

Test Type Activation: .02 .011 Pass .012 Pass Serial Number: 11832 Test Load: 280 281.5  % Load: 1.01 297.3  % Load: 1.06 Mark Number CH-108-R8 Final Drag: 17.5 Pass 1.7 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N 38510 Release: N/A 2-049 Initial Drag: 17.5 4.8 Pass 4.6 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .009 Pass .009 Pass umber: 37657 Test Load: 280 300  % Load: 1.07 287.7  % Load: 1.03 umber 8-15-R10 Final Drag: 17.5 6.5 Pass 6 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results Xm~ltgria Icnsha Em'umaramaa Eesuih 2-050 Initial Drag: 71.9 Pass 82.3 Pass ber:

Te ype SMPL-3 Activation: .02 .015 Pass .011 Pass Serial Number: 16436 Test Load: 12000 12817  % Load: 1.07 12149  % Load: 1.01 Mark Number SI 4201-7741 8 Final Drag: 2500 76.9 Pass 62.6 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: NIA 2-053 Initial Drag: 300 18.8 Pass 16.6 Pass Tag Number:

Test Type SMPL-4 Activation: .02 .014 Pass .009 Pass Serial Number: 16749 Test Load: 4800 5267.1  % Load: 1.1 4201.9  % Load:.88 Mark Number SIP200-63438 Final Drag: 300 19.1 Pass 16 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-054 Initial Drag: 300 16.2 Pass 20.2 Pass Tag Number:

Test Type SMPLA Activation: .02 .013 Pass .006 Pass Serial Number: 16760 Test Load: 4800 5040.7  % Load: 1.05 4210.3  % Load: .88 Mark Number SI4200-63438 Final Drag: 300 21.8 Pass 14.1 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-055 Initial Drag: 300 20.8 Pass 30.1 Pass mber:

SMPL-4 Activation: .02 .015 Pass .013 Pass Serial Number 17709 Test Load: 4800 5252  % Load: 1.09 5070.6  % Load: 1.06 Mark Number SIR200-63408 Final Drag: 300 17.2 Pass 29.9 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-056 Initial Drag: 300 28.5 Pass 31.6 Pass Tag Number:

Test Type SMPLA Activation: .02 .012 Pass .009 Pass Serial Number: 16765 Test Load: 4800 5232.3  % Load: 1.09 4613.8  % Load: .96 Mark Number SI4200-63408 Final Drag: 300 24.4 Pass 25.6 Pass Capacity: PSA-3 Lock up: NIA Rplcmnt S/N Release: N/A 2-057 Initial Drag: 300 18.3 Pass 14.2 Pass Tag Number:

Test Type SMPLR Activation: .02 .009 Pass .007 Pass 16753 4800 5104.5  % Load: 1.06 21.75162.7 % Load: 0 Serial Number: Test Load:

Mark Number SIC200-3268 Final Drag: 300 13.8 Pass 21.7 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: NIA 2-058 Initial Drag: 300 34.8 Pass 14.2 Pass Tag Number:

Test Type SMPL-4 Activation: .02 .012 Pass .007 Pass umber: 21266 Test Load: 4800 4760.6  % Load:.99 4791.5  % Load: 1 umber Sl-4200-322C Final Drag: 300 26.3'ass 23.4 Pass Capacity: PSA-3 Lock up: NIA Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results j.CRf CCl~lR XCQREl ECS~ QglIgZRSK?Q hIQR 2 066 Initial Drag: 145.6 Pass 1118 Fail mber:

ype PREY FAIL Activation: .02 .022 Fail .017 ~ Pass Serial Number: 16610 Test Load: 12000 12887.1  % Load: 1.07 12112.2  % Load: 1.01 Mark Number SI-4203-71 Final Drag: 750 209.9 Pass 615.7 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N 16610 Release: N/A 2-067 Initial Drag: 750 3.1 Pass 124.7 Pass Tag Number:

Test Type PREV FAIL Activation: 0 0 Pass 0 Pass Serial Number: 61256/32 Test Load: 12000 15000  % Load: 1.25 15000  % Load: 1.25 Mark Number SI4201-7760 Final Drag: 750 1000 Fail 1000 Fail Capacity: LSG-3062RF Lock up: 14.72 13.79 Pass g.g2 Pass Rplcmnt S/N 61256/32 Release: 4.72 2.70 Pass 2.55 Pass 2-069 Initial Drag: 17.5 6.3 Pass 6.4 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .006 Pass .005 Pass Serial Number: 38528 Test Load: 280 313.9  % Load: 1.12 6.5308.4 % Load: .02 Mark Number SIR208-264B Final Drag: 17.5 6.9 Pass 6.5 Pass Capacity: PSA-1/4 Lock up: N/A Rptcmnt S/N Release: N/A 2-070 Initial Drag: 300 183.8 Pass 131.1 Pass umber:

pe PREV FAIL Activation: 0 Serial Number: PD 87485-1416 Test Load: 11200 12985.6  % Load: 1.16 12662.1  % Load: 1.13 Mark Number SIP200-6348 Final Drag: 300 175.9 Pass 141.4 Pass Capacity: PMH-2200 Lock up: 30.00 29.18 Pass 26.19 Pass Rplcmnt S/N Release: 30.00 25.33 Pass 24.45 Pass 2-072 Initial Drag: 75 10.5 Pass 5 Pass Tag Number:

Test Type SMPL-3 Activation: .02 .008 Pass .009 Pass Serial Number: 14878 Test Load: 1200 1266  % Load:1.06 1307.2  % Load:1.09 Mark Number Sl-4205-6428B Final Drag: 75 8.3 Pass 7.2 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-074 Initial Drag: 300 15 Pass 15.4 Pass Tag Number:

Test Type SMPL-4 Activation: .02 .010 Pass .008 Pass Serial Number: 16752 Test Load: 4800 4686.3  % Load: .98 4316.2  % Load: .9 Mark Number SIP205-6713B Final Drag: 300 20.9 Pass 11.1 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-075 Initial Drag: 300 30.4 Pass 16.1 Pass Tag Number:

Test Type SMPL-4 Activation: .02 .01 Pass .007 Pass Number: 16769 Test Load: 4800 4743.5  % Load: .99 4528  % Load: .94 umber SIP205-6713B Final Drag: 300 23.8 Pass 23.5 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucle Unit 2 Snubber Test Results 2-079 Initial Drag: 75 15.2 Pass mber:

T SMPL-3 Activation: .02 .008 Pass .008 Pass ypo 24734 1200 1274.9  % Load: 1.06 1275.9 % Load: 1.06 Serial Number: Tost Load:

Mark Number SI-4205-739B Final Drag: 75 7.4 Pass 7.1 Pass Capacity: PSA-1 Lock up: NIA Rplcmnt SIN Release: NIA 2-080 Initial Drag: 75 7.6 Pass 10.6 Pass Tag Number:

Test Type SMPL-3 Activation: .02 .006 Pass .008 Pass 20363 1200 1238.4  % Load: 1.03 1307.9 % Load: 1.09 Ser/al Number: Tost Load:

Mark Number SIP205-6428B Final Drag: 75 11.2 Pass 7.2 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-084 Initial Drag: 300 26.5 Pass 31.7 Pass Tag Number:

Test Type SMPL-3 Activation: .02 .008 Pass .005 Pass 29504 4800 5369.3  % Load: 1.12 4502.8  % Load: .94 Serial Number: Test Load:

Mark Number SI-4204-1100B Final Drag: 300 43.1 Pass 30.8 Pass Capacity: PSA-3 Lock up: NIA Rplcmnt S/N 24745 Release: NIA 2-088 Initial Drag: 75 26.9 Pass 30.5 Pass mber:

SMPL-1 Activation: .02 .02 Pass .017 Pass pe 7419 1200 1319.8  % Load: 1.1 1313.0 % Load: 1.09 Senal Number: Test Load:

Mark Number SI4204-1270B 75 11.1 Pass 13.6 Pass Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N 12289 Release: N/A 2-089 Initial Drag: 75 12.6 Pass 19.7 Pass Tag Number:

Test Type SMPLR Activation: .02 .008 Pass .006 Pass 7313 Test Load: 1200 1203.4  % Load: 1 1349 2 % Load' 12 Serial Number:

Mark Number SI 4204-1270B Final Drag: 75 13.6 Pass 17.4 Pass Capacity: PSA-3 Lock up: NIA Rpicmnt SIN Release: N/A 2-093 Initial Drag: 2500 312.6 Pass 155.5 Pass Tag Number:

PEV.FAIL Activation: .02 .016 Pass .017 Pass Test Type 11971 40000 36950  % Load: .92 43720  % Load: 1.09 Serial Number: Test Load:

Mark Number BF-4007-7017 2500 226.9 Pass 267.8 Pass Final Drag:

Capacity: PSA-35 Lock up: NIA Rplcmnt S/N Release: NIA 2-094 Initial Drag: 2500 545.4 Pass 219.7 Pass Tag Number:

Test Type PEV.FAIL Activation: .02 .018 Pass .018 Pass 8291 40000 235  % Load:.01 225.1  % Load:.01 Number: Tost Load:

umber MS-4100-16A 2500 76.5 Pass 104.7 Pass Final Drag:

Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results Xe~ltexia Icosi'emi@ Gamareasho Eesvlh 2-096 Initial Drag: 6000 1261.4 Pass 1410.6 Pass mber:

PEV.FAIL Activation: .02 .02 Pass .017 Pass pe Serial Number: 2472 Test Load: 96000 95240  % Load: .99 197230  % Load 2 05 MS-4100-16B 6000 1079.3 Pass 1167.9 Pass Mark Number Final Drag:

Capacity: PSA-100 Lock up: N/A Rplcmnt S/N Release: N/A 2-099 Initial Drag: 75 8.1 Pass 6.511.5 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .015 Pass .018 Pass Serial Number: 26006 Test Load: 1200 1296.3  % Load: 1.08 1256.7  % Load: 1.05 Mark Number SIQ203-69B 75 4.2 Pass 7.4 Pass Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N 26006 Release: N/A 2-100 Initial Drag: 75 2.8 Pass 5.1 Pass Tag Number:

SMPL-3 Activation: .02 .010 Pass .010 Pass Test Type 20360 1200 1284.3  % Load: 1.07 1272.1  % Load: 1.06 Serial Number: Test Load:

SI4203-69B 75 3.1 Pass 5 Pass Mark Number Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N 6955 Release: N/A 2-102 Initial Drag: 75 16.6 Pass 18.6 Pass T umber:

PREV FAIL Activation: .02 .016 Pass .011 Pass pe 26062 Test Load: 1200 1344.6  % Load: 1.12 1349.1  % Load: 1.12 Se al Number:

SIP203-24C 75 18.5 Pass 15.1 Pass Mark Number Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-103 Initial Drag: 75 27.6 Pass 14.8 Pass Tag Number:

SMPL-3 Activation: .02 .009 Pass .010 Pass Test Type 14872 1200 1342.4  % Load:1.12 1339.1  % Load:1.12 Serial Number: Test Load:

Mark Number SIR203-24B 75 12.1 Pass 6.7 Pass Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N 14872 Release: N/A 2-104 Initial Drag: 75 15.2 Pass 11.2 Pass Tag Number:

SMPL-3 Activation: .02 .011 Pass .012 Pass Test Type 26010 1200 1310.5  % Load: 1.09 1292,3  % Load: 1.08 Serial Number: Test Load:

SIP203-24B 75 8.3 Pass 13.0 Pass Mark Number Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-106 Initial Drag: 300 46.8 Pass 42.9 Pass Tag Number:

SMPL-1 Activation: .02 .011 Pass .007 Pass Test Type Number: 21267 Test Load: 4800 4901.3  % Load: 1.02 '273.1  % Load: .89 umber SIQ203-581 B 300 31.5 Pass 27.7 Pass Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results 2-107 Initial Drag: 21.2 Pass 22.2 Pass bor:

Te ype SMPLA Activation: .02 18680 Test Load: 4800 5119.6  % Load: 1.07 4884.6  % Load: 1.02 Serial Number:

Mark Number SI4203-581B Final Drag: 300 26.5 Pass 30 8 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-108 Initial Drag: ?5 8.7 Pass 17 Pass Tag Number:

Tost Type SMPL-1 Activation: .02 .013 Pass .013 Pass 14884 Test Load: 1200 1197.3  % Load: 1 1176.3 % Load:.98 Serial Number:

Mark Number SI-4200-314B Final Drag: 75 12.7 Pass 13.7 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-109 Initial Drag: 75 7.3 Pass 6.2 Pass Tag Number:

Test Type SMPLX Activation: .02 .008 Pass .007 Pass 19231 Test Load: 1200 1233.7  % Load: 1.03 1263.7 % Load: 1.05 Serial Number:

Mark Number S IP200-314B Final Drag: 75 8.3 Pass 5.7 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-110 Initial Drag: 750 60.7 Pass 47.7 Pass T mba r.

SMPL-1 Activation: .02 .018 Pass .01 Pass pe Serial Number 11393 Test Load: 12000 12328.3  % Load: 1.03 116485 % Load 97 Mark Number 8FP006-7407 Final Drag: 750 48.3 Pass 60 Pass Capacity: PSA-10 -Lock up: N/A Rplcmnt S/N Release: N/A 2-120 Initial Drag: 2500 294 Pass 313.7 Pass Tag Number:

Test Type PEV.FAIL Activation: .02 .018 Pass .016 Pass 9282 Test Load: 40000 4p64p  % Load; 1.p2 39670  % Load:.99 Serial Number:

Mark Number BF-4007-7008 Final Drag: 2500 109.5 Pass 80.1 Pass Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A 2-124 Initial Drag: 17.5 5.6 Pass 6.4 Pass Tag Number:

Test Typo SMPL-1 Activation: .02 .009 Pass .008 Pass

% Load: 1.08

'80 Serial Number: 29366 Test Load: 296.1  % Load: 1.06 301 Mark Number RS-98-R12 Final Drag: 17.5 5.1 Pass 6 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N Release: N/A 2-125 Initial Drag: 17.5 4.5 Pass 4.5 Pass

'ii, Tag Number:

SMPL-0 Activation: .02 .008 Pass .007 Pass

)jTest Type 37659 Test Load: 280 291.9  % Load: 1.04 298.2  % Load: 1.07 umber:

umber RC-98-R4B Final Drag: 17.5 3.5 Pass 4.6 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N 38489 Release: N/A

St. Lucie Unit 2 Snubber Test Results XeaGritaria IcllKE Emily GamKaz~ Emdh 2-140 Initial Drag: 17.5 2.0 Pass 2.2 Pass mber:

SMPL-1 Activation: .02 .011 Pass .011 Pass Serial Number'2612 Test Load: 280 252. '/0 Load: .9 294.9 '/0 Load: 1.05 Mark Number RC-99-R5 Final Drag: 17.5 1.9 Pass 2.8 Pass Capacity: PSA-1/4 Lock up: NIA Rplcmnt S/N Release: N/A 2-144 Initial Drag: 75 22. Pass 48.5 Pass Tag Number:

Test Type PREV FAIL Activation: .02 .01 Pass .01 Pass Serial Number: 14876 Test Load: 1200 1294.3 '/o Load: 1.08 1233.4 0/0 Load: 1.03 Mark Number RC4300-15 Final Drag: 75 35.2 Pass 42.0 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: NIA 2-146 Initial Drag: 750 78 Pass 64.8 Pass Tag Number:

Test Type PEV.FAIL Activation: .02 .019 Pass .012 Pass Serial Number: 16442 Test Load: 12000 12418.8 '/o Load: 1.03 113p3.3 /o Load: .94 Mark Number RCP300-123 Final Drag: 25 Pass 47 6 Pass 750'/A Capacity: PSA-10 Lock up:

Rplcmnt S/N Release: NIA 2-150 Initial Drag: 75 13 Pass 11.5 Pass T umber pe SMPL-1 Activation: .02 .016 Pass 024 Fail S Number: 14880 Test Load: 1200 1227.6 o/0 Load: 1.02 1203.8 '/o Load: 1 Mark Number RCQ300-125 Final Drag: 75 12.4 Pass 16.1 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N 26002 Release: N/A 2-152 Initial Drag: 75 10 Pass 9.8 Pass Tag Number:

Test Type SMPL-2 Activation: .02 .017 Pass .016 Pass Serial Number: 16141 Test Load: 1200 1212.7 '/o Load: 1.01 1285.5 /0 Load: 1.07 Mark Number RC-4300-28 Final Drag: 75 5.1 Pass 4.6 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-153 Initial Drag: 300 38.8 Pass 37.3 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .017 Pass .01 Pass 16568 4800 4916.3 '/0 Load: 1.02 4453.9 '/0 Load: .93 Serial Number: Test Load:

Mark Number RC-4300-26B Final Drag: 300 39.4 Pass 46.0 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-155 Initial Drag: 750 20.6 Pass 16.9 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .019 Pass .017 Pass umber: 10177 . Test Load: 12000 12751.6 '/o Load: 1.06 1p576.2 /0 Load: .88 umber RCQ300-126 Final Drag: 750 72.1 Pass 42 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results IQSfSZliQdR T i~ ggggjg ~~~ QgggJQ 2-156 Initial Drag: 10.8 Pass 13.5 Pass ber:

Te PREV FAIL Activation: .02 .007 Pass .010 Pass ype Serial Number: 12790 Test Load: 1200 1348,4  % Load: 1,12 1250.2  % Load: 1.04 Mark Number RCR300-64B Final Drag: 75 14.6 Pass 10.5 Pass Capacity: PSA-1 Lock up: N/A Rpicmnt S/N 26008 Release: N/A 2-157 Initial Drag: 75 19.6 Pass 25.2 Pass Tag Number:

Test Type PREV FAIL Activation: .02 .016 Pass .017 Pass 15148 Test Load: 1200 1301.6  % Load: 1.08 1255.9  % Load: 1.05 Serial Number:

Mark Number RC4300-7066 75 5.3 Pass 15.9 Pass Final Drag:

Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-160 Initial Drag: 300 12 Pass 12.8 Pass Tag Number:

Test Type SMPL-2 Activation: .02 ,013 Pass .008 Pass 20253 Test Load: 4800 5155  % Load: 1.07 4338  % Load:.9 Serial Number:

Mark Number RC<300-12 Final Drag: 300 13.1 Pass 13.1 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-161 Initial Drag: 300 17.9 Pass 8.7 Pass mber:

pe SMPL-2 Activation: .02 .013 Pass '008 Pass 20262 Test Load: 4800 5051  % Load: 1.05 4382  % Load: .91 Serial Number Mark Number RCC300-12 Final Drag: 300 11.4 Pass 15.6 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt SIN Release: N/A 2-162 Initial Drag: 750 53.5 Pass 42.5 Pass Tag Number:

SMPL-2 Activation: .02 .019 Pass .011 Pass Test Type 11387 Test Load: 12000 12280.8 %Load:1.02 11225.9 %Load:.94 Serial Number:

Mark Number RCP300-157 Final Drag: 750 51.7 Pass 36.5 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A 2-165 Initial Drag: 750 70 Pass 59.4 Pass Tag Number:

Test Type SMPL-2 Activation: .02 .02 Pass .017 Pass 16439 12000 11494.2  % Load: .96 10744.9 % Load: .9 Serial Number: Test Load:

Mark Number RC<300-157 Final Drag: 750 72.6 Pass 72.5 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A 2-167 Initial Drag 300 184.1 Pass 224.6 Pass Tag Number:

Test Type SMPL-1 Activation: 0 P D87773-1891 11200 13596.4  % Load: 1.21 13142  % Load: 1.17 Number: Test Load:

RC-4300-147 300 163.3 Pass 205.1 Pass umber Final Drag:

Capacity: PMH-2200 Lock up: 30.00 26.85 Pass 24.53 Pass Rplcmnt S/N Release: 30.00 22.93 Pass 22.28 Pass

St. Lucie Unit 2 Snubber Test Results 3y~Cihria jenaiua higa Qgmgrmgiga fhgglh 2-169 Initial Drag: 300 36.1 Pass 28.5 Pass ber:

PREV FAIL Activation: .02 .012 Pass .008 Pass Te ype 101 4800 4887  % Load: 1.02 4262.6  % Load:.89 Serial Number: Test Load:

RCP300-139 300 15.5 Pass 10.4 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt SIN Release: N/A 2-170 Initial Drag: 300 33.9 Pass 25.5 Pass Tag Number:

SMPL-2 Activation: .02 .013 Pass .008 Pass Test Type 20264 4800 5229.1  % Load: 1.09 4497.5  % Load: .94 Serial Number: Test Load:

RC-4300-138 300 11.3 Pass 14 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-172 Initial Drag: 750 49.7 Pass 67.1 Pass Tag Number:

SMPL-2 Activation: .02 .02 Pass .014 Pass Test Type 8934 12000 11174.6  % Load:.93 11373.1 % Load:.95 Serial Number: Test Load:

Mark Number RCQ300-6134C 750 23.2 Pass 34 6 Pass Final Drag:

Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A 2-173 Initial Drag: 750 52.5 Pass 42.2 Pass mber:

SMPL-1 Activation: .02 .017 Pass .012 Pass 11340 12000 11274.7  % Load:.94 11141.0 % Load:.93 Serial Number Test Load:

Mark Number RC-4300-61 34C Final Drag: 750 37.5 Pass 37 7 Pass Capacity: PSA-10 Lock up: N/A Rplcmnt S/N Release: N/A 2-176 Initial Drag: 300 74.5 Pass 80.8 Pass Tag Number:

Test Type SMPL-2 Activation: .02 .012 Pass .011 Pass

'? 4800 5193.5  % Load: 1.08 4640.3  % Load: .97 Serial Number: Test Load:

RC-4300-6134A 300 17.2 Pass 18.9 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-177 Initial Drag 17.5 6.3 Pass 7.2 Pass Tag Number:

Test Type PREV FAIL Activation: .02 .01 Pass .009 Pass 29182 280 273.7  % Load: .98 305.1  % Load: 1.09 Serial Number: Test Load:

Mark Number RC-97-R18 Final Drag: 17.5 8.1 Pass 5.3 Pass Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N Release: N/A 2-178 Initial Drag: 17.5 5.3 Pass 6.3 Pass Tag Number:

PREV FAIL Activation: .02 .013 Pass .013 Pass Test Type 29198 280 294.8  % Load: 1.05 276.5  % Load:.99 umber: Test Load:

umber RC-97-R18 17.5 8.2 Pass 4.4 Pass Final Drag:

Capacity: PSA-1/4 Lock up: N/A Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results Im~C'aia Xeamul Emitted Gmareaahn Emit 2-183 Initial Drag: 75 7.5 Pass mber:

T PEV.FAIL Activation: .02 .01 Pass .017 Pass ype Serial Number: 16663 Test Load: 1200 7.5  % Load: .01 10.3  % Load: .01 Mark Number RC-4300-1067 Final Drag: 75 7.5 Pass 10.3 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-184 Initial Drag: 75 9.6 Pass 4.3 Pass Tag Number:

Test Type SMPL-2 Activation: .02 .016 Pass .018 Pass Serial Number: 19228 Test Load: 1200 1300  % Load: 1.08 1319  % Load: 1.1 Mark Number RC-4300-1067 Final Drag: 75 10 Pass 5.3 Pass Capacity: PSA-1 Lock up: N/A Rpicmnt S/N Release: N/A 2-185 Initial Drag: 300 37.6 Pass 45.1 Pass Tag Number:

Test Type PREY FAIL Activation: .02 .013 Pass .008 Pass Serial Number: 30534 Test Load: 4800 5295.8  % Load: 1.1 4643.5 % Load: .97 Mark Number RC4300-52 Final Drag: 300 40. Pass 41.4 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: NIA 2-186 Initial Drag: 300 31.7 Pass 31.2 Pass umber:

pe SMPL-1 Activation: ,02 .014 Pass .01 Pass Senal Number: 16575 Test Load: 4800 4668.4  % Load: .97 4660.9 % Load: .97 Mark Number RC-4300-53B Final Drag: 300 30.1 Pass 30.1 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-196 Initial Drag: 2500 218.5 Pass 208.6 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .015 Pass .018 Pass Serial Number: 9281 Test Load: 40000 35170  % Load: .88 42270  % Load: 1.06 Mark Number MS-4101-314 Final Drag: 2500 42.5 Pass 79.4 Pass Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: NIA 2-200 Initial Drag: 75 10.3 Pass 7.9 Pass Tag Number:

Test Type SMPL-3 Activation: .02 .008 . Pass .008 Pass 21579 Test Load: 1200 1305.1  % Load: 1.09 1322.1 % Load: 1.1 Serial Number:

Mark Number SI-80-R5 Final Drag: 75 4.2 Pass 14.5 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-206 Initial Drag: 17.5 6.6 Pass 8.6 Pass Tag Number:

Test Type SMPL-1 Activation: .02 .011 Pass .012 Pass 19077 Test Load: 280 303.3  % Load: 1.08 296.3  % Load: 1.06 Number:

umber MSIQ-R6 Final Drag: 17.5 4.0 Pass 4.8 Pass Capacity: PSA-1/4 Lock up: NIA Rplcmnt S/N Release: N/A

St. Lucie Unit 2 Snubber Test Results Ig.'~Cm:fg ICllKKl ECSlklh Q5KS~rgign 2-211 Initial Drag: 300 14.1 Pass ber:

SMPL-4 Activation: .02 .012 Pass .008 Pass Te ype 16578 4800 5190.1  % Load: 1.08 4961.1  % Load: 1.03 Serial Number: Test Load:

Sl-2401<4 300 20.4 Pass 13 0 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: NIA Rplcmnt S/N Release: NIA 2-219 Initial Drag: 300 18.1 Pass 12.7 Pass Tag Number:

SMPL-3 Activation: .02 .011 Pass .008 Pass Test Type 20259 4800 4513.8  % Load: .94 4267.  % Load:.89 Serial Number: Test Load:

CC-2061-101 300 17.5 Pass 13.2 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: NIA 2-222 Initial Drag: 2500 208.9 Pass 119.4 Pass Tag Number:

SMPL-1 Activation: .02 .016 Pass .015 Pass Test Type 7817 40000 36490  % Load:.91 37300  % Load:.93 Serial Number: Test Load:

Mark Number SI-2412-29A 2500 56.3 Pass 30 2 Pass Fina I Drag:

Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: NIA 2-224 Initial Drag: 37.5 4.4 Pass 6.6 Pass mber:

SMPL-1 Activation: .02 .013 Pass .01 Pass 10719 520 532.8  % Load: 1.02 535.8  % Load: 1.03 Serial Number Test Load:

Mark Number CH-2081-685B Final Drag: 37.5 8.4 Pass 6.3 Pass Capacity: PSA-1/2 Lock up: N/A Rplcmnt S/N Release: N/A 2-240 Initial Drag: 300 17.7 Pass 15.1 Pass Tag Number:

SMPL-3 Activation: .02 .01 Pass .008 Pass Test Type 16761 4800 5147,4  % Load: 1.p7 4643.2  % Load: .97 Serial Number: Test Load:

BF-3020-14B 300 18.1 Pass 10 6 Pass Mark Number Final Drag:

Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: NIA 2-241 Initial Drag: 2500 272.8 Pass 251.4 Pass Tag Number:

PREY FAIL Activation: .02 .019 Pass .018 Pass Test Type 7809 40000 4237p  % Load: 1.p6 4211p  % Load: 1.05 Serial Number: Test Load:

MSP102-33 2500 276.8 Pass 222.6 pass Mark Number Final Drag:

Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A 2-242 Initial Drag: 2500 148.9 Pass 121.5 Pass Tag Number:

PREY FAIL Activation: .02 .02 Pass .018 Pass Test Type 7810 40000 39050  % Load:.98 39540  % Load:.99 Number: Test Load:

MS-4102-33 2500 197.6 Pass 85.8 Pass umber Final Drag:

Capacity: PSA-35 Lock up: NIA Rplcmnt S/N Release: NIA

St. Lucie Unit 2 Snubber Test Results

~~CittJ:jg ICl5jQD BCSQlfR Qgm~~ hiljtg, Tag Number 2-243 Initial Drag: 2500 211.2 Pass 195.1 Pass Test Type PEV.FAIL Activation: .02 .017 Pass .015 Pass Serial Number 7808 Test Load: 40000 39760  % Load:.99 39760  % Load: .9!

Mark Number MS4102-287B Final Drag: 2500 333.4 Pass 199 6 Pass Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A Tag Number: 2-246 Initial Drag: 2500 216.4 Pass 203.2 Pass Test Type SMPL-1 Activation: .02 .018 Pass .017 Pass Serial Number: 7814 Test Load: 40000 40580  % Load: 1.01 42140  % Load: 1X Mark Number MS-4102-287A Final Drag: 2500 238.6 Pass 223.5 Pass Capacity: PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A Tag Number: 2-268 Initial Drag: 300 63.3 Pass 64.6 Pass Test Typo SMPL-1 Activation: 0 Serial Number: 61242/04 Test Load: 540 5635.0  % Load: 10.44 5469.5  % Load: 10.

Mark Number B F4004-258 300 43.1 Pass 42.6 Pass Final Drag:

Capacity: LSG-3052 Lock up: 14.17 12.39 Pass 11.06 Pass R plcmnt S/N Release: 4.72 1.95 Pass 1.46 Pass Tag Number: 2-269 Initial Drag: 300 71.8 Pass 71.6 Pass Test Type SMPL-1 Activation: 0 Serial 5lumber 61242/03 Test Load: 540 54657  % Load: 54254  % Load: 10I:

Mark bomber BF-4004-258 Final Drag: 300 56.6 IMP 41 5 Pass Capac".I; LSG-3052 Lock up: 14.17 12.95 Pass 10.07 Pass Rplcrt .t S/N Release: 4.72 1,90 Pass 1.45 Pass Tag tl aber: 2-315 Initial Drag: 2500 508. Pass 315.6 Pass Test ~"po PREV FAIL Activation: .02 .014 Pass .015 Pass Serla< Number: 8458 Test Load: 40000 37440  % Load:.94 43720  % Load: 1.0<

Mark Number MS4102-284 Final Drag: 2500 396.5 Pass 416 2 Pass Capac>ty; PSA-35 Lock up: N/A Rplcmnt S/N Release: N/A Tag Number: 2-316 Initial Drag: 300 45.5 Pass, 46.3 Pass Test Type PREV FAIL Activation: .02 .012 Pass .006 Pass Serial Number: 25740 Test Load: 4800 48923  % Load 1019 44279  % Load: 9.;l Mark Number BF-4004-38 Final Drag: 300 67.6 Pass 37.9 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A Tag Number: 2-322 Initial Drag: 17.5 14.6 Pass 15.8 Pass Test Type PREV FAIL Activation: 0 Serial Number: 61211/58 Test Load: 280 558.9  % Load: 2 556.6  % Load: 1.99 Mark Number MS-7-R2B 17.5 9.9 Pass 9.8 Pass Final Drag:

Capacity: LSG-3018 Lock up: 14.72 11.58 Pass 9.03 Pass Rplcmnt S/N Release: 4.72 3.13 Pass 3.13 Pass

St. Lucie Unit 2 Snubber Test Results

~~CIJ:is[ 1CEdQQ BRRLjJJR GQIEZRKigQ ECgglfli 2-323 Initial Drag: 75 27,7 Pass 42.3 mber:

SMPL-1 Activation: .02 .005 Pass .004 Pass ypo Serial Number: 26064 Test Load: 1200 1277.9  % Load: 1.06 1242.1  % Load: 1.04 Mark Number MS-3023-11 B Final Drag: 75 29.4 Pass 40.1 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-324 Initial Drag: 75 9.4 Pass 6.9 Pass Tag Number:

Test Type SMPL-3 Activation: .02 .007 Pass .007 Pass Serial Number: 26005 Test Load: 1200 1273.4  % Load: 1.06 1286 5  % Load 1 07 Mark Number MS-3023-53 Final Drag: 75 4.5 Pass Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-325 Initial Drag: 75 20.2 Pass 21.3 Pass Tag Number:

Test Typo SMPL-2 Activation: .02 .015 Pass .016 Pass Serial Number: 21596 Test Load: 1200 1294.2  % Load: 1.08 1208.7  % Load: 1.01 Mark Number MS-3023-93 Final Drag: 75 14.4 Pass 20.6 Pass Capacity: PSA-1 Lock up: N/A Rplcmnt S/N Release: N/A 2-332 Initial Drag: 300 47.9 Pass 39.1 Pass umber:

pe SMPL-2 Activation: .02 .014 Pass .007 Pass 25526 Test Load: 4800 52187  % Load: 10.87 45882  % Load: 9.56 Se iai Number:

Mark Number SI-2401-171 Final Drag: 300 55.5 Pass 35.3 Pass Capacity: PSA-3 Lock up: N/A Rplcmnt S/N Release: N/A 2-334 Initial Drag: 17.5 3.4 Pass 7.7 Pass Tag Number:

Test Type PREV FAIL Activation: 0 1 Fail Serial Number: 61211/67 Test Load: 320 565  % Load: 1.77 585  % Load: 1.83 Mark Number VRC-4-R3 Final Drag: 17.5 3.3 Pass 7.6 Pass Capacity: LSG-3018 Lock up: 14.72 11.57 Pass 8.?7 Pass Rplcmnt S/N Release: 4.72 3.53 Pass 2.31 Pass

St. Lucie Unit

~

~ ~

2 L-96-72 Docket No. 50-389 Fall 1995 Refueling Outage NIS-2 OWNER'S REPORTS OF REPAIRS OR REPLACEMENTS

St. Lucie NIS-2 Reports NIS-2 Number Date SL-2-7-001 10/21/94 SL-2-7-010 11/9/93 SL-2-7-011 11/8/93 SL-2-7-012 12/30/92 SL-2-7-014 4/19/93 SL-2-7-019 4/19/93 SL-2-8-001 7/28/94 SL-2-8-002 2/7/96 SL-2-8-003 7/12/95 SL-2-8-004 Working SL-2-8-005 Cancelled SL-2-8-006 Cancelled SL-2-8-007 Cancelled SL-2-8-008 6/28/95 SL-2-8-009 Cancelled SL-2-8-010 Cancelled SL-2-8-011 Cancelled SL-2-8-012 Working SL-2-8-013 12/12/94 SL-2-8-014 Cancelled SL-2-8-015 2/9/95 SL-2-8-016 Not used SL-2-8-017 6/22/95 SL-2-8-018 6/22/95 SL-2-8-019 6/30/95 SL-2-8-020 2/6/96 SL-2-8-021 7/12/95 SL-2-8-022 11/25/96 SL-2-8-023 1/22/96

St. Lucie NIS-2 Reports SL-2-8-024 i2/13/95 SL-2-8-025 11/22/95 SL-2-8-026 11/14/95 SL-2-8-027 11/14/95 SL-2-8-028 11/29/95 SL-2-8-029 11/29/95 SL-2-8-030 Cancelled SL-2-8-031 12/19/95 SL-2-8-032 12/4/95 SL-2-8-033 i2/13/95 SL-2-8-034 12/11/95 SL-2-8-035 12/11/95 SL-2-8-036 12/1/95 SL-2-8-037 11/25/95 SL-2-8-038 11/29/95 SL-2-8-039 11/25/95 SL-2-8-040 i2/2/95 SL-2-8-041 12/12/95 SL-2-8-042 12/5/95 SL-2-8-043 11/27/95 SL-2-8-044 12/12/95 SL-2-8-045 12/18/95 SL-2-8-046 ii/17/95 SL-2-8-047 ii/i3/95 SL-2-8-048 12/18/95 SL-2-8-049 12/13/95 SL-2-8-050 1/18/96 SL-2-8-051 11/29/95 SL-2-8-052 12/7/95 SL-2-8-053 12/7/95

St. Lucie NXS-2 Reports SL-2-8-054 11/2/95 SL-2-8-055 11/17/95 SL-2-8-056 12/27/95 SL-2-8-057 12/18/95 SL-2-8-058 11/14/95 SL-2-8-059 12/18/95 SL-2-8-060 11/21/95 SL-2-8-061 11/24/95 SL-2-8-062 11/20/95 SL-2-8-063 1/18/96 SL-2-8-064 Not Used SL-2-8-065 12/27/95 SL-2-8-066 11/29/95 SL-2-8-067 11/28/95 SL-2-8-068 12/27/95 SL-2-8-069 12/27/95 SL-2-8-070 1/22/96 SL-2-8-071 11/14/95 SL-2-8-072 Combined with SL-2-8-070 SL-2-8-073 11/20/95 SL-2-8-074 12/12/95 SL-2-8-075 1/22/96 SL-2-8-076 12/19/95 SL-2-8-077 3ISIN st~ls~

SL-2-8-078 12/8/95 SL-2-8-079 1/2/96 SL-2-8-080 12/1/95 SL-2-8-081 11/30/95 SL-2-8-082 12/14/95 SL-2-8-083 12/14/95

St. Lucie NIS-2 Reports SL-2-8-084 12/18/95 SL-2-8-085 1/4/96 SL-2-8-086 12/27/95 SL-2-8-087 i2/i3/95 SL-2-8-088 11/29/95 SL-2-8-089 12/13/95 SL-2-8-090 11/25/95 SL-2-8-091 12/7/95 SL-2-8-092 i/2/96 SL-2-8-093 2/5/96 SL-2-8-094 2/5/96 SL-2-8-095 11/29/95 SL-2-8-096 11/29/95 SL-2-8-097 2/1/96 SL-2-8-098 12/11/95 SL-2-8-099 12/2/95 SL-2-8-100 12/8/95 SL-2-8-101 12/6/95 SL-2-8-102 11/29/95 SL-2-8-103 11/28/95 SL-2-8-104 11/28/95 SL-2-8-105 11/30/95 SL-2-8-106 Cancelled SL-2-8-107 1/4/96 SL-2-8-108 Cancelled SL-2-8-109 Cancelled SL-2-8-110 2/6/96 SL-2-8-111 Cancelled

PSL-1, NIS-2 TRACKING NO. S L - 2 ~00 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI II

1. Owner: Florida Power & Light Co: Date: 10/21/94 ."

P.O. Box 529100 Sheen 1 of 4 Miami, FL 33152 Unit: 2

2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jcnscn Beach, FL 34957 PCM ¹: 178-290
3. Work Performed By: Florida Power & Light Co. PWO¹: 4794 6501 South Hwy. A1A WO¹: 92040566 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Intake Cooling Water Type Code Symbol Stamp N/A ICW PP 2B Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: AsME SEcTtON III 1986 EDrraN No ADDfNDA Code Case: NA (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. IdcntiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Pump Byron 761-N-0002 NA 14,000 GPM 1980 Replaced (Less stuffing box) Jackson 130 ft Pump Johnston 901-A-3554 NA 14,000 GPM Replacement (Less stuffing box) Pum 130 ft Column Bolting Byron NA A M SS-164 Replaced Cap screws 1 1/4-7unc '5 Jackson Column Bolting BWID Ht ¹. M2943B/16 NA ASME SB 164 Replacement Cap screws & M2943B/17 1 1/4-7unc '5 Stud -Stuff Bx to Byron NA ASM'B.164 Replaced 3/4 10uncx3

~

Discharge Head Jackson 1/2 Stud-Stuff Bx to Byron Ht¹ NA ASM'B 164 Replacement N 3/4 10uncx3 Discharge Head Jackson M9591B 1 /2

7. Description of Work: REPLACE PUMP W/MODIFIED PUMP WHICH WILLPROVIDE IMPROVED LUBE WATER FLOW TO BEARINGS.
8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic VT 2 x VT 3 ~

Nominal Operating Pressure (ISLT) x psig Test Temp.~'F

PSL-2, NIS-2 TRACKING NO. S L-2 ~001 FORM NIS-2 (Back) Sheet 2 of 4

9. Remarks:
10. Inspection Report Numbers: NA APPLICABLE MANUFACTURES DATA AEPOttTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair x Replacement conforms to the rules of the ASME Code,Section XI.

A Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner Owner's Designee, Title Date ~2.t, 19 t'f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1 inspector's Signature National Board, State, Providence and Endorsement Date

PSL-1, NIS-2 TRACKING NO. S L 0 7-~00 1 FORM NIS-2 01VNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASiME Code Section XI PL SUPPLEMENTAL SHEET

1. Owner. Florida Power & Light Co. Date: 4/22/94 P.O. Box 529100 Miami, FL 33152 Sheet: 3 of 4
2. Plant: St. Lucie Plant Unit ¹: 2 6501 South Hwy. AIA Jensen Beach, FL 34957 P.O. ¹: NA
3. Work Performed By: Florida Power & Light Co. PCM ¹: 178-290 6501 South Hwy. A1A
6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced AS ME Name of Name of Manufacturer Other Year Code Board B d Repaired Component Manufacturer Serial No. Identification Built N or Stamped Replacement (Y or N)

Nut-Stuff Box to Byron NA NA Replaced 3/4 -tounc Hvy H Discharge Head Jackson Nut-Stuff Box to BWIP Ht¹ NA 3/4 -10unc Hvy H NA Replacement Discharge Head M2473BQ Nuts-Discharge Byron NA ASME SB-164 NA Replaced Head to Pedestal Jackson 14uncHex Nuts-Discharge Nova Ht¹ NA ASME SB-164 NA Replacement Head to Pedestal 17155 1 4 unc Hvy Hex Studs-Discharge Byron NA ASME SB-164 NA Replaced Head to Pedestal Jackson 1"-Sunc-4 1/2" Studs-Discharge Nova Ht¹ NA ASME SB-164 NA Replacement N Head to Pedestal 22520 1"-Sunc-4 1/2" Cap screws- Suet Byron NA AS ME B-164 NA Replaced Bell to lmplr case Jackson 3/4"-10unc-4" Cap screws- Suet BWIP Rei PO Doc NA ASME B.164 NA Replacement Bell to Implr case 3/4"-10 unc-4" Nuts- Suet Byron ASTM B-164 NA Replaced Bell to Implr case Jackson 3/4"-10 unc Nuts- Suet BWIP Ref PO Doc ASTM B-164 NA Replacement Bell to Implr case 3/4"-10 unc Studs-Top Case Byron ASME SB164 NA Replaced to Implr Case Jackson 3/4"-10 unc-4" Studs-Top Case BWIP Ht¹ NA, ASME SB164 NA Replacement to Implr Case M2944B 3/4"-10 unc-4" Nuts-Top Case Byron NA Replaced 3/4 - 1ounc to Implr Case Jackson Nuts-Top Case Byron Ht¹ NA 3/4 -lounc Hvy H NA Replacement to Implr Case Jackson M9539B Hex Nuts, Byron NA ASME SB-164 NA Replaced Column Bolting Jackson 1 1/4"-7unc Hex Nuts, Nova Ht¹ NA ASME SB-164 NA Replacement Column Bolting 37165 1 1/4"-7unc Hx

PSL-I, NIS-2 TRACKING NO. S L - 2- 0 7-~00 1 FORM NIS-2 OAVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL SUPPLEMENTAL SHEET

l. Owner. Florida Power & Light Co. Date: 4/22/94 P.O. Box 529100 Miami, FL 33152 Sheet: 4 of 4
2. Plant: St. Lucie Plant Unit ¹: 2 6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA
3. Work Performed By: Florida Power & Light Co. PCM ¹: 178-290 6501 South Hwy. A1A
6. Identification of Components Repaired or Replaced and Replacement Components:

Manufacturer'ational Replaced ASME Name of Name of Other year Code Board Repaired Component Manufacturer Serial No. Identification Built No. of Stamped Replacement (Y or N)

Capscrews-Column Byron NA ASME SB-164 NA Replaced Top Case Jackson 1 1/8"-7unc-5" Capscrews-Column BWIP Ht¹ ASME SB-164 NA Replacement Top Case M33C2BG/111 1 1/8"-7unc-5" Hex Nuts-Column Byron NA ASME SB-164 NA Replaced Top Case Jackson 1 1/8"-7unc Hex Nuts-Column BWIP Ht¹ ASME SB-164 NA Replacement Top Case M2107BG 1 1/8"-7unc Stuffing Box Byron NA ASME SB-148 NA Replaced Jackson CDA 954 Stuffing Box Byron Ht¹ NA ASME SB-148 NA Replacement Jackson M4659 CDA 954 Stuffing Box Byron NF NA NA Replaced Plug Jackson Stuffing Box Byron Ht¹ SB-564 NA Replacement Plug Jackson 674TNE

PSL-1, NIS-2 TRACKING NO. S L 7 - ~01 0 FORM ibIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEi3IIENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/9/93 P.O. Box 529100 ShceL' of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA 3 Work Performed By Florida Power & Light Co. PWO ¹: 5658 6501 South Hwy. A1A WO ¹: 92055870 Jensen Beach, FL 34957

'. (a) Identification of System: Reactor Coolant PRESSURIZER CWO ¹: NA Process Sheet:

Type Code Symbol Stamp, N/A N/A V 1201 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 1

5. (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. of (Y or N)

Replacement SAFETY VALVE CROSBY N 59336 NA 1 979 REPLACED Y 0002 SAFETY VALVE CROSBY N59336 NA NA 1 984 REPLACEME 0004 ALLTHREAD NOVA MACHINE HEAT ¹ SA- 193 NA REPLACEME 1 1/4" X 8 UN X2A PRODUCTS 67094 GR B7 HEAVYHEX NUTS NOVA MACHiNE HEAT ¹ NA SA-194 NA REPLACEME PRODUCTS 8094962 GR7

7. Description of Work: Replace valve and inlet bolting due to seat leakage.
8. Tests Conducted: Hydrostatic Other: VT1 x

~ Pneumatic VT2 x VT 3 ~ Nominal Operating Pressure (ISLT) x

~psig Test Temp.~'F

PSL-2, NIS 2 TRACKING NO. S L 7- ~01 0 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSERVICE LEAIVGE TEST WAS PERFORMED AND ALL REPLACEMENT BOLTING WAS VISUALLYEXAMINEDBY A VT CERTIFIED INSPECTOR.
10. Inspection Report Numbers: M93-369 APPLIDABLE MANUFADTUAE'SDATA REPORTS To BE ATTADHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair x Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A

'Signed Owner or Owner's esignee, Title Date ~is< . 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1 F Co ¹60 Inspector s Signature National Board, State, Providence and Endorsement Date

JL.-l6-1992 13c 85 FROf'1 OPPD CORP S PROC QA TO 9140 4684115 P. 82

\

a CRb SOY VAl VF 4 4 8'8 CO 0 PALY W I th~THAM, MASS iORM NV 1 FOR SA,F E'Z'f hÃD SIAF ETY RRXJEF VAl VES ClaC.MC-l ha required by che f rovislons ot cba Acti@ Code Rules DATA REPORT Safety and Safety Relief Valttee

l. atanuractcua ay Cros Valve 6 Crt e Co. 43 Kendrick S . hrrenthcttn MA 2 DD-EP 86 JISXlXI, Oedda Pewaa &

learns and Address Lldht COOPaoy, 9.0.

JL aaa, DOx DZ9990 I d Q acanufactured For HiamL. Floride 33252 Ordertfo.18656>>22976%3926 Nllme and Address

  • OWlcf Florida Potrer 6 Yd. ht Company St. Lucia Uttit 82 Namn and hddress
4. l:ocatinn af Plant da Spare for V>>1200, V-1201, V 1202 Serial No. N59336 00-0004 Dfa ig No. DS 0 59336 Rev. E
5. Vahw identification a

Relief eel dao alta K plea alta !alta 9 0 Oaa Qdety.safety Relief.lhllct.lhowar Actuated l hah loch laah lao h 700 F S. Scc pressuro <psfa) t Smpvrature 2129182 lbslhr 'tsteotu sat ct ~~ Qvsrp:useure Blowdovyn (pala) 4~ O< Se>.

Stamped Cafztnt ty Htedfrhlhtattn Teat (iPQQ) inlet 3750 Complece Valve T. Tbe pnacsrzat design, oOnsuuccton and vrorkrnanshtp comply vpich AgMK,'Code. Section lg.

Do hddaoda Oha, 1

~ddhdon 9 .hddaoda Date ,Case No.

pressure Concaincruc or tzressure Rvcaining Cumpcznvnts Serial No. idatcrial s penl fioation

a. Casczngs identification including Type ot beads K60802-32-0004 N9L522-33-0004 ASIDE SA35L Gr. CPS Body Bonnet P~r Scoc:k and Fotgtngs SalPPrar~ EOttQBt N91530 32-0004 ARK SALOS hloaxl ~ N91523-34-0008 AS'458 Cx. 651 Disc Xneer t 2 5 0007 A4 8 spring csasbers K60807-32-0004 ~ I Adiusting Bolt N91532 35-0008 ASM SA193 Gr. B6 Sp. Poult N91527 33 0007 ASHZ SA193 Gr. S6

'RN8O6-33-0008 Spindl.e Bal3. h'9152 S A$ . A276 T e 440C Disc Holder N91524~36 0008 AS'K SA637 Gr. 718 Bellowtr K60805 33-0005 Lcu shing NSL525-34-0008 Httyttcs Satellite Alloy No. 68

~ ~

~ I I ~ ~ t I ~ ~

111' ~ ~ ~

~ ~ ~ 1 ~

~ ~ ~

~ ~

~ I i: ~ ~

~ ~

~ V ~ I ~

~

~

4

~, ~ ~ \ I ~ ~ ~ ~

~ ~ ' ~ ~ ~ ~~ ~ ~

Vt +i<I~ I ~

~ I ~

~ ~

~ ~ ~ I ~ ~

~ ~

~ ~ ~ ~ ~

~ ~

Vl~

~ ~

PSL-1, NIS-2 TRACKING NO. S L 7 - ~01 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/8/93 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O ¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 5657 6501 South Hwy. A1A WO ¹: 92055869 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A V 1202 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 1

5. (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement SAFETYVALVE CROSBY N 59336 NA NA 1979 REPLACED 0003 SAFETY VALVE CROSBY N 59336 NA NA 1987 REPLACEME 0005 ALL lHREAD 1/4"-8 UN-2A NOVA MACHINE HEAT ¹ 'A SA 193-74 1989 REPLACEME 1 PRODUCTS 8094962 GR B7 HEAVYHEX NUTS NOVA MACHINE HEAT ¹ NA SA-194 GR 7 1990 REPLACEME 1 1/4"-8 UN-2B PRODUCTS RL3

7. Description of Work: Replace valve and inlet bolting due to seat leakage.
8. Tests Conducted: Hydrostatic Other: VT I x

~ Pneumatic VT 2 x VT 3 ~ pstg Test Temp. ~'F Nominal Operating Pressure (ISLT) x

PSL-2, NIS-2 TRACKING NO. S L-2 ~01 1 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSERVICE LEAKAGETEST WAS PERFORMED AND AU REPIACEMENT BOLTING WAS VISUALLYEXAMINEDBY A VT CERTIFIED INSPECTOR.
10. Inspection Report Numbers: M93-370 APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair +x Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed or 0 er's Designee, Title Da1s ~xl Ia, 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions t inspector's Signature National Board, State, Providence and Endorsement Date

t.KUSIIY 'L'ALYF. F.SG Qlo CNOIIY YALV K CRaS'BY W ft KHTHAM, MASS 8 6A GK CO M PANY FORM gV I FOR SAFETY hgD SAFETY RELIEF VALVES a C.-vC-l hs requited by the Provisions of the ASME Code Rules DATA REPORT Safety and Safety Relief Valves f tured By Crosby Va 1ve & Ga e . Co ., 43 Kendrick S t. Wrenthatn MA game and Address HB-BP"66 hlceel Hc. Order No N74 620 Contract Daty 11/10/86 Vatlooal Board No.

Piorida Power & Light Co. PO Box OI 9 9 Manufactured For Ma>>, Florida 33102 Order go. C18656-79388 game and Address Florida Power & Light Company game and hddtess St. Lucie Unit 2 Jensen Beach, Plorida

4. Locatton of Plant S are Serial go N59336-00-0005 Diawl% go Ds-C-59336. Rev. E S. Valve Identification Safety Safety, Safety Relief.Pilot,Power Actuated

'loe oclllcc Slee 1. 531 lIIcll Slee lech lelel 3 lech ocIleI 6 lllch

s. Set Ptessute (PSIQ) 2485 700 F Rated Tetnperatute 212,182 LBS/HR Sat Stm 4X of S.P.

Stamped Ca)3acity~ tl v Overpressute. BIowdown (PSIQ)

Ilydrr static Test (PSIO) inlet ~ 50 Complete Valve 7 0

7. The material. design. construction and wotkmanship comply with ASME Code, Section m.

No Addenda

,Case No.

Pressure Containing or Ptessute Retaining Components Serial go. Material Specification

a. Castings Identification Including Type or Grade Body K60802-33-0005 N 1522-80-0005 ASTH A 351 Gr. CF8H Bonnet
b. Bar Stock and Forgings ZKtNIMPdK Bonnet N91530>>80-0005 ASM," SA 105 goasle N91523-36-0013 ASTH A 458 Gr. 651 Disc InSert N91526-80-0017 ASTM A 458 Gr. 651 N

Vt 1531-3 spr>rig Nashers K60807-80-0011 Adjusting Bolt N91532-35-0010 ASME SA 193 Gr. B6 Spindle N91527-34-0009 ASME SA 193 Gr. B6 K60806-34-0009 Spindle Ball N91528 ASTH A 276 T e 440C Disc Holder Assy N91524-38-0011 AS."IE SA 637 Gr. 718 K60805-80-0009 Disc Bushing N91525-36-0011

12;02/92 09:29 50S 384 3152 CROSBY VALVE EX(i Serial No. or Material Specification identification including Type or Grade

c. Spring K60807-80-0011 HX3108-0016
d. Bolting
e. Other Parts such as Pilot Components Bonnet Stud 81062 ASME SA l93 Gr. 87 Bonnet Nut 2370 ASME SA 194 Gr. 28 Vle certify that the statements made in this report are correct.

Date 19M~ Signed Crosby Valve 6 GaSe Co.

Manufacturer By Certificate of huthoriaation No, 1878 expires Se tember 30 1989 CERTIFIChTE OF SHOP INSPFCTION I, the undersigned, holding a valid commission issued t% the National Board of Boiler and Pressure Vessel Inspectors and the State or province of and employed by Arkwri ht Mutual Insurance Com an have inspecce c e equ pment describe !n this ata Report on 19 and state that to the best of n:y knov:ledge and belief. the Manufacturer has constructed this equip.

ment in accordance with the applicable Subsections of hSMF. Section tll.

'By signing chis certificate, neither the Inspector nor his employer makes any ivacranty, ex.

pressed or implied. concerning the equipment described in this Data Report.Fur!hermore, neither che Inspector nor his employer shall be liable in any manner for any personal injury or propercy damage or a loss of any kind arising from or connected with (his inspection.

Date Factory Mutual System Commis s tons (Inspector) National Board. State. Province and No.>

PSL-1, NIS-2 TRACKING NO. S L-2 ~01 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of'he ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/30/92 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co.

PWO¹. 2702 6501 South Hwy. A1A WO ¹: 92002640 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A

4. (a) IdentificationofSystem: Safety Injection Type Code Symbol Stamp N/A (b) Component Identification: V 3466 Authorization No. N/A (Mark Number) Expiration Date N/A (c) Code Class: 2

. (a) Applicable Construction Code ANSI B31.7, 1969 Edition. Addenda: N/A. Code Case: N A (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1980 Edition thru winter 1980

6. IdentiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Disc Insert Crosby N 89531-38-0 SA 479 Type 1 979 Replaced 11 316 Disc Insert Crosby N89431-42-0 ASTM A-479 1992 Replacement 20 T e 316 Nozzle Crosby N 90557-35-0 SA 479 Type 1979 Replaced 13 316 Nozzle Crosby N 90557-38-0 NA SA 479 1985 Replacement 22 T e 316 Spindle Crosby K55444-37-0 NA SA 479 1 979 Replaced 19 T e 316 Spindle Crosby K55444-48-0 SA 479 1991 Replacement 33 T e 316

7. Description of Work: Replaced disc 8 nozzle due to leakage.
8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic VT 2 x VT 3 ~'F Nominal Operating Pressure (ISLT) x

~pstg Test Temp

PSL-2, NIS-2 TRACKING NO. S L-2 ~01 2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory leakage test was performed and witnessed by a VT 2 certified inspector.
10. Inspection Report Numbers: M92-1538 APPLICABLE MANUFACTURES OATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair x Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed wner or Own r's Designee, Title Data ~aa, 19 p~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Insurance of Norwood Mass.

have inspected the components described in this Owner's Report during operating cycle ¹7 starting on 06/92, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspsctor's Signature National Board, State, Providence and EndorseRIents Date - Iz

PSL 2, NIS 2 TRACKING NO. 8 L. 2. p 7~ay FORM VIS-2 OWNER'S REPORT FOR REPhlRS OR REPLACEMENTS As Required by the Provlafons of tbe ASME Code Section Xl

1. Owner. Florida Power 4, Light Co. Os~: CIPPt s-P.O. Box 529100 Miami, FL 33152 Shcct: 1 of &
2. Plant: St. Lucic Plant Unit >>; 2 6501 South Hwy. AlA Jensen Beach, FL 34957 PO.>>; qgq9Q - 98O& 0
3. cwork Performed By: Florida Power 8c Light Co. PCM>>: 4//t 6501 South Hwy. A1A Jcnscn Beach. FL 34957 PWO>>: ~/8 XA>>: </jg 8090 Be30- /ddr PA CW0>>: Bg+Q Process Sheet: $ ~8- /yy/4'z Repair Orf,anizadon P.O. No., Job No., eet.

Type Code Symbol Stamp N/A Authorization No, N/A Expiration Date N/A

4. ldcntification of System:

PQ 5 t'R855UR f a8R

5. (a) Applicable Construction Code ASME Secuon ill, 1977 Edition, Summer 1977 Addenda.

f'r

~ Code Cases (b) Applicable Edition Winter 1980 addenda.

of Section

~ Xl Utilized Code Cases Repairs and Replacement Components 1980 Edition, thru the 6, Identification of Components Repaired or Replaced and Replacement Components:

National Replaced AS ME Name of Name of Manufacturer Other Year Board Repaired Code Component Manufacturer Serial No. No.

Identification Built or Stamped Replacement (Y or N)

QOMSO&2 ldyyJ H 6'kf nlO.

( Id9. 5 gg'~ CnJ6 ra6'CRwlh f Z+Z6 kPth~eitl r N0 CaGA R ClLM &tP2 2 < 0 ysJ k8N'tO.

I 0 Nut fdhld&dknlU ff "l't4 kPVLKHHur N0

7. Description of Work: IHPC8 5 r OOS AHQ 68/tR rdA5 vugg'Pf-AMG M 'M6 PR855 URtKGie'- NRnJ5/flY.
8. Tests Cendusted: Hydtostatte Other

~ Pneutnatte Pressure ps'est Nominal Operating Pressure Tem . 'F

PSL.2, NIS 2 TRACKING NO. S L ~ 2 ~ 07.~D FORM 'HIS-2 (Sack) Sheol 2 of W 9, Remarks. Q f ) gf 565&gNg~

I~+@p~+~gg ACUTE Ngg ggMwlC< g~CRPl8D gh @Jeer Afiit EJ~

r gWASL8 I ff RoCSf/

PA.Q.K A~ neo.eP>PSC8 Vl- Z. WeS far-f-Oa~ea OAj~P e.~O ~8.

APIsLICASLS MAHVCACTV%'tOATA RSPORIS TO SS ATTACh4O Certificate of Compliance we cenity thai lhe slalsmenls made in the reparl are carreal and this conforms to the rules of the ASME Code,Section XI.

QRspair Q Replacemenl Type Code Symbol Stamp: NIA Certificale of Authorization No.: NIA Signed O,ts 4.I t"1 i293 Owner or Owner Des oo, Titl~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiier and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright fnsurance of Norwood Mass, have inspected the components described in this Owner's Report during operating cycle 407 starting on

'b(2t 3 and state that to the best of my knowledge and belief. the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cerlificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in lhe Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property:damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's SlgrIalure National Board. Stato, Providence and Endorsements Dale D~

C ~

1 4 J

~ ~ ~ ~ ~

~ ~ ~

~ ~ ~

~ ~ ~ ~

~ I . ~

0 ~

~

~ I ~

~

~ ~ ~

~ ~ ~

~ ~ ~ . ~

I ~

~

~

~ rar ~

~

~ ~ ~ ~ ~

~ '

~ ~ ~ ~

~ ~ ~ ~

s . ~

~ ~ ~ ~ ~ I I ~ I t ~ ~ ~ ~

~

' ~ ~ I ~ ~ ~ ~ I ~ ~ I i ~ ~ ~ 'll ~ ~

':I .st ~ . ~ r

'I ~ ~ ~ ~ ~, I ~ ~ ~ . ~ I ~ ~ ~

~ . ~ ~ ~

~ ~ r

~ '

I~SR' rr . gg L

HMH

%MR L

'RR x

~: ~ ~ o ~

HMH A

~:,

A

~ ~ ~ . ~ ~

PSL.2, NIS 2 TRACKING NO. S L - 2 ~ 0 9.~OI FORM NIS-2 (Sack) Sheet 2 of&

9. Remarks: L Q g ( I 0 68 f'GP.f-af.'/ I E~~ 75M '( F ~I C1 ( OUt'.

APKCASLS LiH4UfAClUAE'S OATA 22EPOATt TO OS ArTsLCHisO Certificate of Compltance We oehtty that Ihe stalemenls made In the report are correol and lhts Q Repatr@J Rsplaoemenl conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Autho 'ion No.: N/A Signed Ownor or Owner's eslgn o, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright fnsurance of Norwood Mass.

have inspected the components described in this Owner's Report during operating cycle NO'7startlng on .

95 and state that to the best of my knowledge and belief, the Owner has performed examinations and '5) and taken correctivo measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning Ihe examinations and corrective measures descibed in the Owner's Report.

Furthermore, neithor the inspector nor his employer shall be liable In any manner for any personal injury or property:damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Stgnature National Board, State, Providence and Endorsements Date C'

e PSL-1, NIS-2 TRACKING NO. S L-2 ~00 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 7/28/94 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA 3 Work Performed By'lorida Power &, Light Co. PWO¹: 0074 6501 South Hwy. A1A WO ¹: 94010469 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identificationof System: Aux Feedwater Type Code Symbol Stamp N/A V09119 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME SEcr III 1974/SuMMEtt 76 Aoo Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Pipe PLug Pacific Valve ASME Replaced 1/2" SA 105 Pipe Plug Tioga Pipe Heat ¹ NA ASME 1991 Replacement 1/2" Ca itol Mf . 2F3720 SA 105

7. Description of Work: REPLACE 1/2" PIPE PLUG FOR VALVE DUE TO LEAGAGE FROM PIPE THREADS.

LINE ¹ I-4-BF-29

8. Tests Conducted: Hydrostatic Other: VT I

~

'T Pneumatic 2 X VT 3 ~

Nominal Operating Pressure (ISLT) X petg Teet Temp.~'F

PSL-2, NIS-2 TRACKING NO. S L 0- ~00 1 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MM94-1080 APPLCABLE MANUFACTURES OATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner Owner's Designee, Title Date I Z, 19~9 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Ig ature National Board, State, Providence and Endorsement Date

PSL-1, NIS-2 TRACKING NO. S L 8 - 002 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 02/07/96 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: NY 422537 6501 South Hwy. AIA PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8218
3. Work Performed By: Florida Power & Light Co. WO ¹: 95032001-01 6501 South Hwy. A1A WCD ¹: 'N/A Jensen Beach, FL 34957
4. (a) Identification of System CCW Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVETCV-14MB Expiration Date N/A (Mark Number)

(c) Code Class:

5. (a) Applicable Construction Code and Addenda: ASME 1974 S 1974 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

VALVE- 30" HENRY PRATT SA 516 WR 70 CO. D0095-1-1 N/A N/A 1979 REPLACED YES VALVE-30" HENRY PRATT RIR¹ 3K-0347 SA 516 - GR 70 CO. D0095-1-2 N/A & 3RB-1430 1979 REPLACEMENT YES STUDS- SA193 ALLIED NUT 1 1/4-8UN2A AND BOLT 62413 N/A RIR¹ 2J-0232 1994 REPLACEMENT NUTS- SA194 ALLIED NUT 1 1/44UN2B AND BOLT E97187 N/A RIR¹ 2J4761 1993 REPLACEMENT

7. DESCRIPTION OF WORK: VALVE REPLACEMENT PER DISPOSITION OF STAR 950764.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other: VT1 [] VT2[X] VT3[] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HDURs

PSL-1, NIS-2TRACKING NO. S L-2 002 FORM NIS-2 (Back) Sheet 2 of

9. Remarks ISLT WAS SATISFACTORILY PERFORMED AND WITNESSED BY A VT2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: M95-452 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date +I Owners or Owner's sign Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Ownei's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements J

Date

0

)(eat! g ta<<PY) tt Ctttylf)ClalC ttt.'tt)CRS fs Aeetoireaf lay lt c tco)rhinos Lbhietette)CS Ly 3))Cm) )XCCC. CO..

aeasILRL<< J 9RP:pet If<<or<<eon)5!))Cresset 'I Certstacrtc ttnlCke) s ~

Le."yA I:LpOIIT t Ult ot atsc ASt tC Coafr hS C 5 )a>a,g ~JATO) l'UCllhll I'Uf573 0 5 Vf:VC'e Sects)et LLC)slsr.

A en cM CrnJ~)

)

7. Leo&rite Stoa XloTLeto J'os:ep..(.J 5R)tt Ca ...SJ.<< ltsc5p Ucaac p'a~e e< ra eve ~ temsesee ~ ) ~ lwegtl "r" n XOX~P<<reC~XPXi&

S, CO 4$ O'I elf<<are rc tsre aev raur nr

~rt L~ S. ~r" ~t S4e~g" c.n

. ')

c cr I;o.~

I code) tto NX Ct ) tt CeetlPecote Scat<<I Hut<<Ice's Rct) lc) Cosset~

tt own gl C)rocatny CI) kotl. CO) Yc or So)cart oc Type Mcs ttc). tto<<)c) Close CcL )to

))a~I'eea sii i l

~ a se i- e II s e- )I A 1979 "A

0}

Cq

~ ~ ~

)ySI)rg~

gi~LC~~~s Lrvetvyn)ct Syotcra wp 0 r <<vs<<I L Ccocn Cceaef)Cons tv<<ceo<<act ttc~e~v el

~

<<vv>> sa

~ +

\

u aae ~

e) i<<

)L Colt'Lt~af preSSaeee ~ v ~ ~

ZZ$ pal OC %OS. ~

' s~ ~

~ ~

L tycssasre p<oXny farces

4) Catt~no

<<a<< <<Le~r

~~

s'-

)t. rL tto tabb LtsttA1 Socc.

KLt'.~I

~

c New lou Octa e o Rcenoets e

~ ~ i c

~ ~

~ ~ a

n. 'T5<<

Nr~~s

' ';Ta~eh)elf t 1

.<<lie<<la h.tifLave i iafthr...,

C )litt SL S"ha 1'1"i ~ t)30 a<<Jl.

V

~ st u)s inc te ~ ta [QJfig!s'1

~

~

\~

~ ~

~ c ~ a'<<n 5 a e ~ ie ~ i, sessL's%' e ' s Ctl lee ns)no&I. cpcect~l i.~s o Pg. ~ ~

~ ~

1 Siiltl ~ i 11 i'I ha fa r) 1 ea ~ I<<, lt I

~ e- 1 re a roose'. nasg Le sscaf pr 'tal ltl I sr I C IO )1 lt 5 J tref<<sana, Inn tre k ans I, 7 ~ rae S e ~ teu'srtv As pasn la saa'area<<I en co ls ~ tv rt, mat llt a <<ls lhra Ia 1~ nr Iree ~ I as 1 nnss t<r a f 1!assis I' as "so<<fast I a,i<<at 1' Ives 1

~

it lv., Rl ~ ~ ~ ~ ~ .'~ ~ 'a ah, ~ ~ ~, ~ 1 ~

' 'll

0

~ >> ~ '

f0 }.st.e'se I last-)

htse'L N 1 t.l,i<<IMf<eo. taL ~ ~,4 I.flic/I r rt rLI.I.S IS l>>CII Jl B~g<<trs Cover aatt 8/! l'}3 C:W. BI S. C I n el 1 l L ~lr '4 ~

Thur Pln SC SS Trays tr Iep Mech<< 5 fl(s F~<< ld

~thr.

's is><<f y

~ c t I<<g Ehher Pa<<ss S A'7 nhns hi J'n e B<<s<<I~ She)T S/S II elt~eec I '! >lb 1,;t. Fg I"' ~C see>> beets."Hl'.I I/Il clleele IISS AI ss gl< a% 10 lth'eh>> Steel sl Te LQ!CClsyega Bgt~CfsvOC <<ss)1

e. ~>> 421 cs. I>>cc;: c. ~o CKR) IFCATt CF CO)IVI.tWMS 4 .'.;-s s~ p;~ ee <<hsee.

.~Cff<<~lc~

eels ty cehse tehe stsetl-crrs sneer V'}ye ara awccc anl f>>se SL 5 co ffcsrns ea ae ruses ot yes:-'I <<~ I<<>> ' t tlrcc cc>>ee>> Q I cc 0 . I f Acct>>*es w<<Ills es<<set

.c c>>e ee. I 4>>

5'dne<<) Dtfsty..f!att rs c<<ef 'LIsss Cw ses p<<es htt Q p<<shscce.hf'case of pfaaariA.tf N<<h Jblsil se use stfe 'lfne ssn+eee ~cs very OnC pa ".3L CMT Fff-.fl)fe)s) 4}P aasfa))

aeth3/1 bstorrner~ On fde asere T'catt Co 4O) S~'.h)and~h, Queo~ca Tf,~ff)l ec ~>>tcesscccycehleecyccc~Q I 'I .Ser ': CC>>cy>>CCIC>>chefye&ehe cecal tcs>>Mc soy s. -&SIB ~ ~

St/esc en@'jt 5 ch>>fag tcscsc I///I I!) Bb}nehrrs net rs.tubed. LM rhsms dbf (})

Sy r.e/h..

o 1}y.

\ ~ ~

s:ER)lFIC'!YE <<C SIIG> LISPS)ION

'4

)I she undessusnehh hah.".rg a us If c"1 encl}stun fshued hp the tf It:c<<LSI go:rd a t'oger asst ptsshure Vessel bifpe.toes

~ nd she Sssse or l'IIs<<fr Lc oA) ).L!'Lo N l end eneltoted by - V..~..IS LT~AJ f;Qe Ot ~lar 1}rc~7e~nna llsie In}peel>>d ttfa Nufrp <<}r T the dceclche f 411 ttl 5 Ossa tfcpcet SbuC<<ed Shie punlffh Or >>S' bi OCecsf Jsr e Shith the hgh'b COde, Seht O<>fg sh}s ersri(eCS}t ne fhl'1 ther tcshfheetnr rur Hs cn pfcyer msles ally sir SntP hy CSPfceStd or beIF} et <<er~ 3 the e<<tufpment <<frserihed 'In OIIS Oaea Arpole. Futthercner 4, neither the tnt 1>>>>cror ner his enchfeyes chil be 14h'e t<<1 Snf manner t cr any p recech.d tn,ury Or pl.q iuty Itamrge Or a Ia.S Cf eny Send enS nff teem Or Cerneded Sn}'h fhft fnfpest} <

( ji ~X:-

asf..>

stt.'sh i~'8/tr. lic ~ .~

r'er I'

I) ~>.

+>vs. r SDI .. c'e}nile'es bslss + +gag frl rl nr n el<< less, ssa rl'll

PSL-I, NIS-2 TRACKING NO. S L-2 ~00 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 07/12/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plank St. Lucie Nuclear Plant 6501 South Hwy. AlA P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 2032 6501 South Hwy. A1A WO ¹: 91026981 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 3 Volume Control Type Code Symbol Stamp N/A V2328 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME SEGT. Ill 74 EDinow/No ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. IdentiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Relief Valve Crosby Valve SA 351 Replaced N 59200.00-0003 CFBM ( BODY)

Relief Valve Crosby Valve S/N SA 351 1988 Replacement N 59200.00-0005 CFSM ( BODY)

7. Description of Work: Replace charging pump 2C relief valve due to body to bonnet leak
8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic, VT 2 X VT 3 ~

Nominal Operating Pressure (ISLT) X psig Test Temp.~'P

PSL-2, NIS-2 TRACKING NO. S L-2 ~00 3 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MMg5 44g APPLICABLE MANUFACTURE'S OATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair +XReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 4ukg~ u I Date 19 t%

Own or 0 r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations arid corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions F ¹ 0 inspector's Signature National Board, State, Providence and Endorsements Date 19~4

PSL-1, NIS-2 TRACKING NO. S L-2 ~00 8 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 06/28/95 P.O. Box 529100 S heeL' of 2 Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 0236 6501 South Hwy. A1A WO ¹: 94013291 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identificationof System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification: V2345 l7-0 s-r0D Expiration Date N/A IMsrkNemrrer) (31re Nljg I re)I (c) Code Class: 2
5. (a) Applicable Construction Code and Addenda: ASME SFcr III 1974 Eomow No AooEwoA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Disc Insert Crosby Vaive S/N SA 479 1 974 Replaced 2 x 3/600 psig N89431-38-0012 T e 316 Disc Insert Crosby Valve S/N NA SA 476 1 993 Replacement 2x 3/600psig 89431-43-0024 T e31

7. Description of Work: Replace disc due to leakage, valve sent to stores for use as spare.

S/N N59197-00-0001

8. Tests Conducted: Hydrostatic Orher:VT1

~ VT2 Pneumatic VT3 Nominal Operating Pressure (ISLT) X.

~psIg Test Temp.~'F

PSL-2, NIS-2 TRACKING NO. S L-2 ~008 FORM NIS-2 (Back) Sheet 2 of

9. Remarks: Q ~@do> VW-K M~% pQP&rnhgg,.

2'0.

Inspection Report Numbers: II/t, IVI,C,Q - ( QQ APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance J

We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner sg. P r Owner's Designee, Title rv - t6 Date l t, 19~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1 F Com ¹60 Inspec or's Signature National Board, State, Providence and Endorsements 19 92

PSL-1, NIS-2 TRACKING NO. S L 8- ~01 3 FORM NIS-Z OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/12/94 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA 3 Work performed By Florida Power & Light Co. PWO¹: 2089 6501 South Hwy. A1A WO ¹: 94029274 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 8 Volume Control Type Code Symbol Stamp N/A CHG-PP-2B Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME Sect tll 1971 EDmow W72 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replaccmcnt Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Stuffing Sox Union Pump SN SA 479 1974 Replaced N73 2246-602 Gr 410 Stuffing Box Union Pump SN33760813300 7607 SA 479. 1985 Replacement N Ht¹ 53046 Gr 410

7. Description of Work: Replace stuffing box assembly due to leakage.
8. Tests Conducted: Hydrostatic Other: VT 1

~ Pneumatic VT 2 X VT 3 ~ Nominal Operating Pressure (ISLT) X

~pstg Test Temp.~'F

PSL-2, NIS-2 TRACKING NO. S L-2 ~01 3 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.,
10. Inspection Report Numbers: MMg4-20g4 APPLCABLE MANUFACTURES DATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed SCCA+ V (S ( pe1eDc1- 1S, 19~7 Owner Own 'esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 7 m¹ Inspector's Signature National Board, State, Providence and Endorsement Date

ee PSL-g, NIS-2 TRACKING NO. S L-2 ~01 0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 2/9/95 P.O. Box 529100 Sheet; 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power &, Light Co. PWO¹: 2488 6501 South Hwy. AlA WO ¹: 95003025 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identificationof System: INSTRUMENTAIR Type Code Symbol Stamp N/A MD -IA-15-R1 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda:, NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement HANGER(U-BOLT) BERGEN-PATER NA PART¹ NA REPLACED N att 6500 HANGER(U-BOLT) BERGEN. PATER RIR ¹ NA REPLACEM N CN 3AF-4708

7. Description of Work: REPLACE U BOLT WHICH WAS FOUND MISSING.

LINE ¹ 2-IA-75

8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic VT 2 VT 3 X Nominal Operating Pressure (ISLT)

~pstg Test Temp.~'P

PSL-2, NIS-2 TRACKING NO. S L - 2 ~01 0 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: VT-3 PERFORMED BY QC-EXAMINATIONOF U-BOLT INSTALLATIONONLY (S L-2-8-01 5)
10. Inspection Report Numbers: MM95 088 APPLCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this /Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed w or 0 er's Designee, Title Date ~<I, t9~l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions ¹ inspector's Sig ature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. S L 8 - ~01 7 FORM NIS-2 OWNERtS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 06/22/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 015-295M
3. Work Performed By: Florida Power & Light Co. PWO¹: 2549 6501 South Hwy. A1A WO ¹: 95003598 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 6 Volume Control Type Code Symbol Stamp N/A LCV-2110P Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME SEc1'III 1971 Eomm/W72 Aoo Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. or (Y or N)

Replacement Spindle / Plug Control Heat No SA 479 1992 Replaced 2" / 1500lb Com onents Inc 606083 GR 316 Spindle / Plug Control Heat No SA 479 SA316 1995 Replacement 2" / 1500lb Inc 4 Stellite 6 C

7. Description of Work: Replace stem/plug assembly which was found damaged
8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic VT 2 X VT3 Nominal Operating Pressure (ISLT) X

~pstg Test Temp.~'3

PSL-2, NIS-2 TRACKING NO. S L - 2 ~01 7 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT -2 certified inspector.
10. Inspection Report Numbers: MM95-41 9 APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Own or 0 0

er's Designee, Title Data ~27, 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1 m¹ Inspector's ignature National Board, State, Providence and Endorsements Date I 19 CS

PSL-I, NIS-2 TRACKING NO. S L 8 - ~01 8 FORM NIS-2 OYVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 06/22/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 015-295
3. Work Performed By: Florida Power & Light Co. PWO¹: 2685 6501 South Hwy. A1A WO ¹: 95005451 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identificationof System: Chemical & Volume Control Type Code Symbol Stamp N/A LCV.21100 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME SEcT III 1971 Eornow/W 72 ADO Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Rcplaccmcnt Components: 1989 Edition.
6. IdentiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. of (Y or N)

Replacement Seat Ring Control NA NA SA 479 Replaced 2" /1500 Ib GR 316 Com onents Inc Seat Ring Control Ht No NA SA 479 SA316 1994 Replacement 2 /1500lb Co o Stelllted Spindle / Plug Control NA SA 479 NA Replaced 2" / 1500lb GR 316 Com one ts Inc Spindle / Plug Control Ht No SA 479 SA316 1995 Replacement 2" / 1500!b Stellite 6 Com n Inc

7. Description of Work: Replaced seat ring and spindle / plug assembly.
8. Tests Conducted: Hydrostatic Other:VT t

~ VT2 Pneumatic x VT3 Nominal Operating Pressure (ISLT) x

~pstg Test Temp.~'F

PSL-2, NIS-2 TRACKING NO. S L-2 ~01 8 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT -2 certified inspector.
10. Inspection Report Numbers: MM95-438 APPLICABLE MANUFACTURES DATA REPDRTB To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair x Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed se. Stst Date <~ +7, 19~

Owner o wn 'esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requiremenls of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1 m¹ 0 Inspector's Signature National Board, State, Providence and Endorsements 19~

O.

PSL-1, NIS-2 TRACKING NO. S L 0- ~01 9 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 06/30/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By. Florida Power & Light Co. PWO¹: 4099 6501 South Hwy. AIA WO ¹: 95011304 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 8 Volume Control Type Code Symbol Stamp N/A Charging Pump 2A Authorization No. N/A (b) Component identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: AsME sEcT III 74 Eo/SuMMER 74 Aoo Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired "Stamped Material No. No. or (Y or N)

Replacement Stuffing Box Union NA SA 479 NA Replaced Pum T e 304 Stuffing Box Union Heat No NA SA 479 NA Replacement m 3 4 4 Nuts (Cover flange) Union NA SA 194 NA Replaced 1 1/4 Rune-28 Pum Gr 6 Nu'ts (Cover ffeoge) Nova Heat No ASME SA 194 NA Replacement N, 1 1/4"4unw28 8 1 Nuts(Valve cover) Union NA SA 194 Replaced 1 1/4 4unc-28 Gr u

Nuts ((Valve cover) Nova Heat No NA ASME SA 194 NA Replacement 1 1/4 4unc-28 871201 Gr 6

7. Description of Work: Replaced stuffing box due to leakage and nuts due to galling.
8. Tests Conducted: Hydrostatic Other: VT I

~ Pneumatic VT 2 X VT 3 ~

Nominal Operating Pressure (ISLT) X pstg Test Temp.~'F

PSL2, NIS2 TRACKING NO. S L 9 - ~01 9 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.

1 0. Inspection Report Numbers: MM95-584 APPLIGABLE MANUPAGTURE's DATA REPORTs To BE ATTAGHEO Certificate of Compliance Wa certify that the statements made in the report are correct and this Repair QRepiacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 8 I o

rg wner's Designee, Title

~ or - ZKT'r Date ~VI ito . f9~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 71 m¹ inspector's gnature National Board, State, Providence and fndorsements Date

PSL-2, NIS-2 TRACKING NO. SL-2C- ~020 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 2/6/96 P.O. Box 529100 Sheet: 1 of Miam, FL 33152 Unit: 2
2. Plant: St. Lucio Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 386-288D
3. Work Performed By: Florida Power 4 Light Co. PWO¹: 0775 6501 South Hwy. A1A WO ¹: 94010958 JcnsenBcach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical & Volume Control Type Code Symbol Stamp N/A CHPP 2C Authorization No. N/A (b) Component N/A Identification: Expiration Date (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SEC. III 71 ED-72 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

SUCTION SPOOL UNION PUMP NA SA564 GR630 NA Replacement PIECE CAP SCREW

7. Description of Work: REPLACE CAP SCREWS WHICH WERE REMOVED DURING MAINTENANCEOF PUMP.
6. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 ~

Nominal Operating Pressure (ISLT) psig Test Temp.

X

'F

PSL-2, NIS-2 TRACKING NO. SL-2C- ~020 FORM NIS-2 (Back) Sheet 2 of 2

9. Remai'ks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: MM95-1919 APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACNED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Ca~eQk 6 <0~G er o ei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

C By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

g1g4 Commissions NB7719 FL Com ¹ 6889')

Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. S L 8- ~02 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 07/12/95 P.O. Box 529100 SheeL 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 7756 6501 South Hwy. A1A WO ¹: 93020470 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identificationof System: Chemical & Volume Control Type Code Symbol Stamp N/A V2326 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 2

5. (a) Applicable Construction Code and Addenda: ASME SECT. III 74 EDrnON /No ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized. for Repairs and Replacement Components: 1989 Edition.
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired Stamped Material No. No. (Y or N)

'I'eplacement Disc Insert Crosby Valve S/N NA Haynes Stelllte NA Replaced 1 1/2" X2" N91102-51-0080 Alloy 68 Disc Insert Crosby Valve S/N Haynes Stelllte 1987 Replacement 1 1/2" X2" N911 02-99-0065 Alloy 68 Nozzle Crosby Valve S/N NA ASME SA 479 NA Replaced 1 1/2" X2" N 91469-34-0013 Type 316 Nozzle Crosby Valve S/N NA ASME SA 479 1988 Replacement 1 1/2" X2" N91469-36-0015 Type 316

7. Description of Work: Rebuild valve SN N59200-00-0005.

Replaced disc and Nozzle Valve to be used as spare.

8. Tests Conducted: Hydrostatic Other: VT I

~ VT 2 Pneumatic VT 3 Nominal Operating Pressure (ISLT)

~psig Test Temp.~'2

PSL-2, NIS-2 TRACKING NO. S L-2 ~021 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: None
10. Inspection Report Numbers: NA APPLICABLE MANUFACTUAESDATA AEPOItTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.:

Signed 0 ner o N/A mfa'- ZVPV, LGi, wner's Designee, Title Date h I, 19 95 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions F ¹60 tnspec or's Sig ature National Board, State, Providence and Endorsements Date 19~5

PSL-1, NIS-2 TRACKING NO. SL-2 022 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/25/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 2160 6501 South Hwy. A1A WO ¹: 94030738 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Intake Cooling Water Type Code Symbol Stamp N/A Authorization No. N/A (b) Component SB 21251 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 3 a) Applicable Construction Code and Addenda: ASME Section III, 1971 edition, no ad. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

STEEL PLATE BETHLEHEM STEE RIR ¹ NA ASME SA 51 5 G Replacement 3/8 X48 X96 2FC318 70 FW 2000 FPL WELD TRAVL¹ NA ¹ LINE CW-20 NA NEW WELD BUTT WELD 95-2712 FW 2000 FPL WELD TRAV¹ NA LINE ¹ CW-21 NA NEW WELD BUTT WELD 95-2713

7. Description of Work: REMOVE VALVES AND CAP OFF PIPING WITH PLATE. MATERIAL. NEW WELD ADDED.
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 ~pstg TestTemp. ~'F Nominal Operating Pressure (tgLT)

PSL-2, NIS-2 TRACKING NO. SL-2 ~022 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: go<<i VG L<+<~

I

10. Inspection Report Numbers: 2-Z PT- Q l APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed I I Date Ioae 29 Owner'wner's Designee, Title 19'ERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVs Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 Inspector's Signature National Board, State, Providence and Endorsements Date /f, 19~

7'of 9 TECHNICAL DEPARTMENT PROCEDURE NO. 2-IPT-32, REVISI ST. LUCIE UNIT 2 'B'agy HYDROSTATIC PRESSURE TEST ICW LOOP TEST DATA SHEET TEST DES CRIP77ON SYS ESC I Q SYSTEM LEAKAGE TEST 'B'NTAKE COOLING WATER PUMP DISC Q SYSTEM FUNCTIONALTEST Q SYSTEM LNSERV(CE TEST SYSTEM CODE CLASS: Q 1(A) ~ 3(C)

~ SYSTEM HYDROSTATIC TEST SYSTEM DESIGN PRESSURE: 90 PSIG Q SYSTEM PNEUMATIC TEST SYSTEM OP. PRESSURE: 60 PSIG Q INSTRUMENTED INSPECTION (IIT) SYSTEM DESIGN TEMP: 125 oF DRAWING(S)'2(B)90 SYSTEM OP. TEMP.: 'F QSCHEDULED QUNSCHEDULED'EPAIR REFERENCE 2998-&482 Current Revision Q REPLACEMENTS'REVIEW by ISI REQUIRED TEST CONDmONS TEST CONDmON HOLD TIME TEST MEDIUM: SEA WATER INSULATED N 0 NIN SU IATED 'I WATER CHEMISTRY: NOMINALICW Q 0-MIN (SYS LEAKAGE) 0 MIN (SYS LEAKAGE)

PLANT SOURCE: Screen Wash Pumps Q 10-M(N (FUNCTIONAL) , Q 10-MIN (FUNCTIONAL)

Q 10-MIN (PNEUMATIC) Q 10-MIN (PNEUMATIC)

TEST TEMP: AMBIENT '.F Q 4-HOUR {HYDRO) ~ 10-MIN {HYDRO)

'F Q 4-HOUR (INSERVICE) 10 MIN (INSERVICE)

EXAM. TEMP: AMBIENT ANII WETNESS TEST TIMETABLE 77ME DATE

~

Q REQUIRED ANII

~Sea. coal DATK WAIVED ACHIEVED TEST CONDITIONS ACHIEVED REQUIRED HOLD TiME COMPLETED VT-2 EXAMINATION I 190 I(-id<

1 -2.g+

TEST RESULTS

SUMMARY

MEASURING & TEST EQUIP. IDENT.

Z. 30Z. le~ MASTER GAUGE ~

II-~3qS BACKUP GAUGE /j->>.

EXAMJTEST PERSONNEL METHOD LEVEL V7 2-a GATE.~Z"I DISCREPANCIES FINAL TEST REVIEW Q STAR TEST SUPV. ATE: -?

Q NPWO AN!I: DATE:

0 OTHER

/ ST. LUCIE UNIT 2 TECHNICAL DEPARTMENT PROCEDURE NO. 2-IPT-31, REVISION Page 7 of 10 PRESSURE TEST ICMI LOOP A AND C 3"'-'YDROSTATIC TEST DATA SHEET System

Description:

Q System Leakage Test Intake Coolin Water Pum Disch Q System Functional Test AB C Q System Inservice Test System Code Class Q 1 (A) Q 2 (B)

General Test 8 System Hydrostatic Test System Design Pressure - 90 PSIG Data Q System Pneumatic Test System Op. Pressure 60 PSIG Q Instrumented lns ection I System Design Temp: 125 'F Q Scheduled Q unscheduled'g System Op. Temp: 90$ 5 dF Repair' Replacements'ISI Reference Drawing(s) 29986-082 Coordinator Review Current Revision T Conditions Test ondition Hold Time Test medium: Sea Water Ins la N nin I Water Chemistry: Nominal ICW Q 0-min {Sys Leakage) Q 0-min (sys Leakage)

Test Plant Source: Screen Wash Pum s Q 10-min {Functional) Q 10.min (Functional)

Parameters Q 10-min {Pneumatic) Q 10-min {Pneumatic)

Test Temperature: Ambient 'F Q 2-hour (IIT) 0 10-min (Hydro)

Q 4-hour (Hydro) Q 10-min (lnservice)

Exam. Tem .: Ambient 'F Q 4-hour lnservice Q10-min I ANII Witne s Test Timetabl Z mme D te O Rgerered MWei~ed Achieved Tes n 'i n ANII Date tr-i A hi vedRe ui oldTime I VT- x i i n 22, << I{

T t Resul s Summa Me 'n Te ui Id nt I Da e

-ZS IO-Sl-9 Test sAza~s I~ cku au -Z 0-Sl Implementation SBZ{Z.<l A trgz.S Exam JTest Pere nnel Method L vel lR<s T~< AeemcbPfFS RYbPe U<~

~Lu~~g oo t4P<O 2-/f,o Di re an ie ~nal Te t eview Post Ef~ Test Eng~.. Date:/ -/l 85 Test C6WO a SOI  %~0 ISI Coor .: Date: II Q Other ANII'. Date:~6~

PSL-2, NIS-2 TRACKING NO. SL-2 ~023 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.'wner: Florida Power & Light Co. Date: 1/22/96 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2

2. Plant: St. Lucie Nuclear Plant 6501 South Hvvy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Povver & Light Co. PWO¹: 4812 6501 South Hwy. A1A WO ¹: 95023706 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdenQication of System Chemical & Volume Control Type Code Symbol Stamp N/A CHG PP 2B Authorization No. N/A (b) Component Identification: Expiration Date . N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: ASME SEC. III; 1971 ED.;W72 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification Stamped oi'eplacement Material (Yor N)

FLUID BLACK UNION PUMP N52918-N S/N 2 NA SA182 TYPE 304 1976 Replaced ASSEMBLY FLUID BLACK UNION PUMP N52918-N S/N 2 NA SA182 TYPE 304 1988 Replacement ASSEMBLY

7. Description of Work: REPLACE FLUID BLOCK DUE TO CRACKING.
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLT)

~psig TestTemp.

X

'F

PSL-2, NIS-2 TRACKING NO. SL-2 ~023 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: Wg Q APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A sISne8 t 4 A sR (88>T 5IPU - Isi Date ~2., 19~~

er or 0 r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 inspector's Signature National Board, State, Providence and Endorsements Date

PSL-I, NIS-2 TRACKING NO. SL-2 ~824 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/13/95 P.O. Box 529100 Sheet:

Miami, FL 33152 Unit: 2

2. Plant: St. Lucic Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 4058 6501 South Hwy. A1A WO ¹: 95012105 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3414 Authorization No. N/A (b) Component N/A Identification: Expiration Date (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement (Yor N)

Seal Weld NA Ht No ER 316 Replacement (FW 2003) GT 6100 0434 (P8 to P8)

7. Description of Work: Remove and replace seal weld to facilitate valve work.
8. Tests Conducted: Hydrostatic Other: VTI

~ Pneumatic VT2 X VT3 Nominai Operating Pressure (ISLTI

~Psig TestTemP.

X

'F

PSL-2, NIS-2 TRACKING NO. SL-24I- ~024 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MM95-2352 APPUCABLE MANUFACTURE'S DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed vmer Auuk, vmeVs Designee, Title o t/. lS( CaIe ~l., IS~5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this OwneVs Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 I spector's Signature National Board, State, Providence and Endorsements Date , 19~%

PSL-1, NIS-2 TRACKING NO. SL-2 025 FORM NIS-2 OWNERt S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power k Light Co. Date: 11/22/95 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power k Light Co. PWO ¹: 2821 6501 South Hwy. A1A WO ¹: 95007333 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3551 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification or Stamped Material Replacement (Yor N)

SEAL WELD FPL WELD TRAVELO NA SA-182 316 SS Replacement FW-2002 ¹ 95-2473

7. Description of Work: Remove and replace seal weld to facilitate valve work.
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 ~pstg TestTemp. ~'P Nominal Operating Pressure (ISLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 ~025 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: fA K t 5 - Q~ ~ I APPUCABLE MANUFACTURES DATA REPDRTB To BE ATrACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 'cCC er's Designee, Title Pu lhl Date ~0t/~ 19~

Ow er or CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the OwneVs Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NtS-2 TRACKING NO. SL-2C- ~026 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power 4 Light Co. Date: 11/14/95 P.O. Box 529100 Slleet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power k Light Co. PWO¹: 2418 6501 South Hwy. AlA WO ¹. 95001976 Jensen Beach, FL 34957 s CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety InJection Type Code Symbol Stamp N/A HCV-3616 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Yor N)

Seal Weld NA Ht No NA P8To P8 NA Replacement DT 6289 ER 316

7. Description of Work: Remove seal weld for valve inspection and reweld following examination.
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLT)

~psig Test Temp. ~'F X

PSL-2, NIS-2 TRACKING NO. SL-2 ~026 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: PA)RQ G -Q, K5+

APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Owner r AR ei's Designee, Title Date ~AV I 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this OwneVs Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVS Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

8v inspectors S!gnature Commissions NB7719 FL Com ¹60 National Board, State, Providence and Endorsements Date / 19 <6

0 PSL-1, NIS-2 TRACKING NO. SL-2 027 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/14/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AlA P.O.¹: NA JcnscnBeach, FL 34957 PCM¹: NA

'. Work Performed By: Florida Power & Light Co. PWO ¹: 2863 6501 South Hwy. A1A WO ¹: 95009205 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A

4. (a) IdenQication of System: Safety Injection Type Code Symbol Stamp N/A V3523 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. IdentiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

Seal Weld NA Ht No DT6289 NA P8To P8 NA Replaced ER 316 Filler (SA-182 FQ16) Seal Weld

7. Description of Work: Remove seal weld for valve inspection and reweld following examination.
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLT)

~psig Test Temp.

X

'F

PSL-2, NiS-2TRACKtNG NO. SL-2 ~927 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: 'g INQ Q Q,RES APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTADHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed I A a K PLtttttr R%/- Date ~CI/ t5 19~7 Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorscments Date

PSL-I, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS EP As Rcquircd by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.lf: NA Jensen Beach, FL 34957 PCM/I: NA 3, Work Performed By Florida Power & Light Co. PWO//: 8726 6501 South Hwy. AIA WO f/: 94007112 Jensen Beach, FL 34957 CWO f/: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A MV-08-1 B Authorization No. N/A (b) Component Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME Sect III 1974 Ed/S 74Add. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code Of No. No. Identification Stamped OI'eplacement Material (Yor N) isc tern o e eat o ep ace Assembly H2261 TP 316 Disc tern o e ena o 4 963 ep acement Assembly H6572 TP 316

7. Description of Work: Replaced stem/disc assembly, oui" +'~~ ~'+~Qc

- requires seal weld replacement. Tracked on PWO 95013022 'ote NIS No. SL-2-8-039

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. ~

SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: (5% $ 5- g,~ I@

APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed <Q. P~,

ner's Designee, Title Date~L'~, 19~

wner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

1 By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions inspector's Signature National Board, State, Providence and Endorsements Date , 19~~.

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of 3 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.//: NA Jensen Beach, FL 34957 PCM f/: 009-293M
3. Work Performed By'lorida Power Ec Light Co. PWO f/:

6501 South Hwy. AIA WO f/: 94005831 Jensen Beach, FL 34957 CWO f/: Process Sheet: N/A

4. (a) Identification of System: Service Air Type Code Symbol Stamp N/A V1 81270 Authorization No. N/A (b) Component Identification: (service air) Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: ASME Sect III 1986 Edition No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N) a e 0 e ep ace 2 Check a e n or a mg 10 ep acement 2 Check Ipe 2 aw 06 ep ace Sch 40 GrB pe 2 icago u e ron 106 ep acemen Sch 40 2J122 GrB 200 so et e rave er i er ep acement (Old weld No FW 14) 95-2739 ER7082 2 so et e rave er 06 i er ep acement (Old weld No FW13) 95-2740 ER7082

7. Description of Work: Replaced valve due to leakage. replace by welding. Includes replacement of section of piping.

(This valve is a CIVI penis)

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 3

9. Remarks: A satisfactory pneumatic test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed er or ner's Designee, Title i Kopv Date ~Cl, IS~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-I, NIS-2 TRACKING NO. SL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of thc ASME Code Section XI PL SUPPLEMENTAL SHEET

1. Owner: Florida Power 0 Light Co. Date: 4f22I94 P.O. Box 529100 Miami, FL 33152 Sheet: 3 of 3
2. Plant: St. Lucie Plant Unit ¹:

6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA

3. Work Performed By: Florida Power & Light Co. 'PCM ¹: 009-293M 6501 South Hwy. AIA
6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced ASME Name of Name of Manufacturer Other Year Board Repaired Code Component Manufacturer Serial or Heat Identification Built No. No. Stamped OI'eplacement (Y or N) so e e rave er e rave er ep acemen (Old weld No FW 12) 95-2741 95-2740

FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR VALVESe AI RequIgod by tne f)rovtahf)I of the ASME Code, Se0tIon III, DlvIalon 1

'Pg. of Manufactured snd certified by Anchor/Darl i ng Va 1 ve Co ., 70 1 Fi rst St ., Wi 1 1 i amspor t, PA 1770 (nano end address of N Cart(()cata Ho(dar)

M f ctu sd f F1 ori da Power 8 Li ht Com an, P. 0. 8ox 029950, Ni ami, FL 33102-9950 (nsms and address of Purchaser or Owner) 3, Location of Installation

4. Model No., Series No., or Type Gb ore~

(nemo and address)

W9323936 R . A cjjN=

ted)don) (addenda date) (dass) (Coda Case no.)

II 2n Nominal Inlet s(a 2 B. Pump or valve (In.)

7 Mater(a). Body SA216-WCB Bonnet 0 6 -600-10 Ij lal lbl Icl ldl Iel cen. Nat'I Body Bonnet Olsk Ho(der'a Board Serial Serial Serial Ser(al No. No. No. No. No.

E-T488 1 N/ T C A761A E-T 88-5-2 N A HT.¹C0607 T A 61A

'Suoo(ements( lnfonnsoon in form of ((ets, sketches. or drawings may be used provided l1) e(ae ls 8)5' 11, (2l infonnaoon in (terna 1 through 4 on this Oats iteoort is included on each sheet, (3) each sheet is numbered snd the number of sheets is recorded at the too of the form.

('I 2/88) this form (8)0037) msy be obtained from the Order Oeot.. ASM8. 22 Law Or(vs. Box 2300. Febfleld, NJ 07007 2300.

isk '- +g-2.Q- 0 Q.Q iR f~ at~

~ W page

ST. LUCI IT 2 ts OPERATItla PROCEDURE NO. 2-1300051, REVISION $ 3 LOCAL LEAK RATE TEST DATA SHEET 4 Test Procedure Penetration No:

Note: Make a list of ail caps and flanges that are removed, ln the Remarks Stat)on Alr {Pg. 1 of 2)

Section below. Type Test: Bypass 5, Qt osa sglgl2.$ 'I H)get o Test Pressure: 41.8 (+1.1, %) psig

1. Close V-18-1253,+~%-, SH-18-797. Test Media: Air or N,
2. Open V-18-784 and V-18-1271 (Vent Path). he> SH- IS- f254.

Test Locat)on: 23'ontainment

3. Pressurize against 2-IY-18-1270 through SH-18-1254. 1" female adapter
4. Measure and record leakage. Test Fittings Required; lose V-18-784 and t-HCV-18-2.

S10pen SH-18-1252 (Vent Path).

X$ Pressurize against l-HCV-18-2 through V-18-1271.

g') Measure and record leakage.

Sl>Close SH-18-1252. Valve No. 2-lv-18-1270 I-HCV-18-2 16:llOpen V-18-784 (See page 2 of 2).

Gauge Serial No.

a..Two go.~e~ ~sWtt, to,~ca >~ I V't.o a{ fsoues-Qsyr L~ r Tv r C'~~v'~ r =c>(o ~ m~4.

JS %AT fa~p Q

<<~4~04 ~R f5',eg~Sa~++C eel.eve ~+ t l~ p~s(+O,-g a~ Rotameter Serial No. T6--/5

> ~wWQecl est K~V raS'r CArRW ~~~ Po~ Rotameter Range 5QC~ \ 5 /sZS lg.Q., fs) struts y ANll O'C,LAcu+ N p &r@sst,gg~

l'ts /s &ehgallt) sm<Peaes~ /&+Sat,rt ~ f pSt,

/Q5 pygmy (yg~)

Date Time Start

-z/-p

)t'o +e 6'+ 4 Time End S /O o

Ai4~ HoQ'~ ~~+P~S~Se usda'<a.

~4aLle W Jf $(fS~)P5 g Pressure Start

$'Or lO artois gsa4qsa p6 +arm 'tr/T2 O C ttff1jff~7 g ~Q . Pressure End o4-8~ 5cwpmgckp as xeekpP lych"reaa&DC~ Le mai<4;s~

) ~ Leakage (SCCM)

~eP~~~~>t>e.+n+ bau.<da.~ +L P~ +es+cm+ v&9,

)S.S P-o(.eeJ +~ s~~, ~ Leakage Limit (SCCM)

Verified By 8,000 8,000 RoasonForTest:

Remarks; G18MonthSorveittanoe le>>

0 ril -R Vi F-0-

seau tv..~Q 6 PreMaint gP stMaint CI Other

~m~ /-~'I PS

-2.I V T~/Z r//z/<$

~CCruLC<4Iree Ptr CSbsa sC AC&

Sntattraa...oAs os. APrJso Sto2.t(t,i

PSL-2, NIS-2 TRACKING NO. S L 8 - 31 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of thc ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/19/95 P. O. Box 529100 Sheet: 1 of 5 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. AIA PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8507
3. Work Performed By: Florida Power & Light Co. WO ¹: 95026315-01 6501 South Hwy. AIA WCD ¹: 0244 Jensen Beach, FL 34957
4. (a) Identification of System 2A a 2B DIEsEL oIL TRANsFER LINEs Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 1-2"-DO-62 & 1-2"-DO-63 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1974 S 1974 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

PIPE - 2" SA106GR. B NIA NIA N/A NIA N/A REPLACED NO PIPE - 2" TIOGA PIPE HT.¹ 637224 UTC 379890 SA 106 GR. B SUPPLY & N68491 N/A RIR 29032 1995 REPLACEMENT NO PIPE -3" TIOGA PIPE HEAT ¹ UTC 381359 SA 106 GR. B SUPPLY N 68491 RIR 2J-1100 1994 MODIFICATION NO

7. DESCRIPTION OF WORK: LEAKAGE OF 13 GAL. PER DAY IDENTIFIED IN ORIGINAL LINE. REPLACEMENT WITH MODIFICATIONTO PROVIDE IMPROVED CORROSION PROTECTION.
8. Test Conducted: Hydrostatic [ X] Pneumatic [X ] Nominal Operating Pressure (ISLT) [ X]

Other: VT 1 [ ] VT 2 [X ] VT 3 f ] HYDRo-150 PSIG Test Temp. 1HR. @ sYs. F IsLT-110 PSIG Test Temp. 10 MIN.e sYs. F

PSL-1, NIS-2TRACKING NO. S L-2 31 FORM NIS-2 (Back) Sheet 2 of

9. Remarks HYDRosTATIG TEsTs AND IsLTwERE sUGGEssFULLY PERFoRMED AND WITNESSED BY CERTIFIED Q.C. INSPECTORS.
10. Inspection Report Numbers: ISLT - M95438 HYDRO'S- M95-157, M95-196, M95-197, M95-377, M95-388, 8 M95-389 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X ] Replacement /

f ] Modification conforms to the rules of the Asme Code,Section XI.

X Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date QeC. k l, 19 15 Owners orOwner's DB gnee, TI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date 19~<'

PSL-2, NIS-2TRACKING NO. S L-2 31 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/19/95 P. O. Box 529100 Sheet: 3 of 5 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: 096-295 Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SAlA Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

FLANGE - 2" SA 105 NIA N/A NIA NIA NIA Replaced FLANGE-2" TIOGA PIPE HEAT ¹ UTC 377921'IR SA 105 SUPPLY 8866369 NIA 27412 1995 Replacement ELBOW -2" SA 105 90 DEG. N/A NIA NIA NIA Replaced HT.¹ R143S, ELBOW-2" TIOGA PIPE 8867888, RIR¹ 29401, SA 105 90 DEG. SUPPLY 8869827 N/A 2K~46 1995 Replacement ELBOW -1 1/2" SA 105 90 DEG. N/A N/A N/A N/A NIA Replaced NO ELBOW -1 1/2" TIOGA PIPE HEAT ¹ UTC 340391 SA 105 90 DEG. SUPPLY R28C N/A RIR 2K-0195 1995 Replacement NO ELBOW - 2" SA 105 45 DEG. N/A NIA N/A NIA NIA Replaced NO ELBOW - 2" SA 105 45 DEG. HUB, INC. ¹ HEAT MC-81 NIA UTC 378122 1988 Replacement UNION - 1 1/2" SA 105 N/A NIA NIA N/A N/A Replaced NO UNION - 1 1/2" TIOGA PIPE HEAT¹ 26215 UTC 34272 SA 105 SUPPLY (NUT) 28332 N/A RIR 2H-3441 1993 Replacement NO COUPLING - 2" SA 105 N/A NIA NIA N/A Replaced NO COUPLING - 2" TIOGA PIPE HEAT ¹ UTC 380213 SA 105 SUPPLY M46010 N/A RIR 29401 1995 Replacement NO COUPLING - 2" SA 105 NIA N/A NIA NIA NIA Replaced COUPLING - 2" TIOGA PIPE HT. CODE UTC 384011 SA 105 SUPPLY 008J N/A RIR 33042 1995 Replacement NO

PSL-2, NIS-2 TRACKING NO. S L 8- 31 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/19/95 P. O. Box 529100 Sheet: 4 of 5 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A I A PCM ¹: 096-295 Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SAI A Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. Replacement (Yor N)

REDUCER - 1 1/2" SA 105 N/A N/A NIA N/A Replaced NO REDUCER - 1 1/2" DUBOSE UTC 372132 SA 105 NAT'L ENR. HEAT ¹009G N/A RIR 2D-7774 1995 Replacement NO BAR,FlAT- A36 INTERSTATE UTC 366048 1/4" X 8" STEEL HT.¹ 227640 N/A RIR R82-2191 1982 Replacement BAR,FLAT - A36 UTC 378632 1/4" X 1/2" HUB INC. HT.¹ G7511 NIA RIR3AH-2235 1993 Replacement BAR,FLAT- A36 INTERSTATE UTC 365966 3" X 1/2" STEEL HT.¹ 16663 NIA RIR R82-1515 1982 Replacement NO BAR,FLAT - A36 UTC 372171 4" X 1/2" ENERGY STEEL ¹ HT 642767 N/A RIR 3AJ-1414 1994 Replacement BAR,FLAT- A36 DUBOSE UTC 378748 12" X 1/2" NAT'L ENR. HT ¹ K34177 N/A RIR 3AJ4666 1994 Replacement NO BAR,FLAT - A36 INTERSTATE UTC 365976-1 314" X 2 1/2" STEEL ¹ HEAT 25748 NIA RIR 4R4258 1984 Replacement NO ANGLE - A36 DUBOSE UTC 372122 2" X2" X1/4" NAT'L ENR. ¹ HEAT J4710 NIA RIR 3AK4606 1995 Replacement NO ANGLE - A36 'TC 372126 3" X3" X1/4" ¹ ENERGY STEEL HEAT 831674 NIA RIR3AK4238B 1995 Replacement NO RND BAR-A36 DUBOSE UTC 377719 1/2" FOR U-BOLT NAT'L ENR. HEAT¹ 831674 NIA RIR 3AJ-1 369 N/A Replacement NO U-BOLT A36 BERGEN BP PART¹ UTC 378467 2" PIPE SIZE PATTERSON 6510-2" N/A RIR 27761 1995 Replacement NO U-BOLT A36 BERGEN BP PART ¹ UTC 373880 2" PIPE SIZE PATTERSON 6510-2" NIA RIR 3AF<708 1992 Replacement NO BOLT, SA 193 ALLIED NUT UTC 372563 5/8"-1 1UNC 2A AND BOLT HT.¹ 86240 N/A RIR 2H-1962 1993 Replacement NO

PSL-2, NIS-2 TRACKING NO. S L-2 31 FORM NIS-2 OWVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/19/95 P. O. Box 529100 Sheet: 5 of 5 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: 096-295 Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SAIA Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

NUT, HEAVY HEX SA 194 GR. 7 ALLIEDNUT HEAT ¹ UTC 377946 1/2"-13 UNC 2B AND BOLT 8865606 N/A RIR 2J-0423 1994 Replacement NO NUT, HEAVY HEX A 563 GR. A ALLIEDNUT HEAT ¹ UTC 371763 3/8"-16 UNC 2B AND BOLT L04058 N/A RIR 3AJ-1253 1994 Replacement No NUT, HEAVY HEX SA 194 GR. 7 ALLIED NUT HEAT ¹ UTC 375497 5/8"-11 UNC 2B AND BOLT L63812 N/A RIR 25731 1995 Replacement NO NUT, HEAVY HEX SA 194 GR. 2H ALLIEDNUT HEAT ¹ UTC 377897:

5/8"-11 UNC 2B AND BOLT 151603 N/A RIR 27358 1995 Replacement NUT, HEAVY HEX SA 194 GR. 2H ALLIEDNUT HEAT ¹ UTC 372081 5/8"-11 UNC 2B AND BOLT 151603 N/A RIR 22763 1995 Replacement NO

PSL-1, NIS-2 TRACKING NO. SL-2<- ~032 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/4/95 P.O. Box 529100 Sheet: 1 of 2 Miam, FL 33152 Unit: 2
2. Plant: St. Lucic Nuclear Plant 6501 South Hwy. AlA P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 009-293M
3. Work Performed By: Florida Power & Light Co. PWO¹: 3640 6501 South Hwy. A1A WO ¹: 93017569 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical & Volume Control Type Code Symbol Stamp N/A V2169 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SEC.III;1971 ED.-'73 ADDENDUM Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. IdentiTication of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N) 2'ISTON CHECK ROCKWELL NA SA 182 TP 316 1978 Replaced VALVE EDWARD 2'ISTON CHECK ANCHOR DARLING S/N: ET 401938 NA SA 351; CF 8M 1993 Replacement VALVE CH 104 FW 600 FPL WELD TRAV¹ NA SOCKET WELD Replacement 95-2324 (VALVE-PIPE)

CH 104 FW 601 FPL WELD TRAV¹ NA SOCKET WELD 1995 Replacement 95-2325 (VALVE-PIPE)

7. Description of Work: REPLACED VALVEAND ASSOCIATED WELDS CH-104-SW 14 &15 AS PART OF A MODIFICATIONTO CORRECT SEAT LEAKAGE PROBLEMS.
8. Tests Conducted: Hydrostatic Other: VT1 X X Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLT)

~pstg Test Temp. ~'P

PSL-2, NIS-2TRACKING NO. SL-2 032 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: NEW WELDS WERE EXAMINEDBY THE LIQUID PENETRANT METHOD BY CERTIFIED INSPECTORS. A HYDROSTATIC TEST OF THE NEW ASSEMBLY WAS PERFORMED. NO LEAKAGE EVIDENT.
10. Inspection Report Numbers: OST HYDRO RPT¹ 3640 APPLICABLE MANUFACTURES oATAREPORTSTO BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed GP

  • Date&~ 19~

r r s Oasignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

dM Commissions NB7719 FL Com ¹60 spector's Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2TRACKING NO. S L-2 33 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/13/95 P. O. Box 529100 Sheet: I of 3 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. f/: N/A 6501 South Hwy. AIA PCM 0: 058-295 Jensen Beach, FL 34957 NPWO 0: 8234
3. Work Performed By: Florida Power & Light Co. WO ¹: 95020553-01 6501 South Hwy. AIA WCD ¹: 0220 Jensen Beach, FL 34957
4. (a) Identification of System COMPONENT COOLING Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 'A'UPPLY HD'R. 1-8"<C<7 TAG SB 14628 Expiration Date N/A (Mark Number) 'A'ETURN HD'R. 1-8 "<C-50 TAG SB14629

'B'UPPLY HD'R. 1-8'<C-53 TAG SB 14630 (c) Code Class: 3 'B'ETURN HD'R 1-8"<C-54 TAG SB14631

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

VALVE- 6" HENRY PRATT SERIAL¹ UTC 380404 A'UPPLY HD'R SA 516 GR. 70 CO. DD375-1-1 N/A RIR 29783 1995 MOD.

VALVE- 6" HENRY PRATT SERIAL¹ UTC 380406 A'RETURN SA 516 GR. 70 CO. DD375-1-3 N/A RIR 29783 1995 HD'R MOD.

VALVE- 6" HENRY PRAYI'O.

SERIAL¹ UTC 380405 B'UPPLY HD'R SA 516 GR. 70 DD375-1-2 N/A RIR 29783 1995 MOD.

VALVE- 6" HENRY PRATT SERIAL¹ UTC 380408 B'RETURN SA 516 GR. 70 CO. DD375-1A N/A RIR 29783 1995 HD'R MOD.

7. DESCRIPTION OF WORK: PERMANENT MODIFICATIONTO SUPPLY A/C TO CONTAINMENTTO REDUCE MAN REM I MAN HOURS FOR CONTAINMENTJOBS.
8. Test Conducted: Hydrostatic [X ] Pneumatic [] Nominal Operating Pressure (ISLT) [ ]

Other. VT1 [] VT2[X] VT3 [] 195 PSIG Test Temp. sYsTEM F Hold Time 10 MINUTEs

PSL-1, NIS-2TRACKING NO. S L-2 33 FORM NIS-2 (Back) Sheet 2 of

9. Remarks A HYDROSTATIC PRESSURE TEST WAS SUCCESSFULLY PERFORMED ON THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
10. Inspection Report Numbers: M95-166 FOR 'A'EADER M95-070 FOR 'B'EADER APPLICABLE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ ] Replacement

[X ] Modification conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date% ( lR'5, 19 OwnersorOwne s Desig ee, Title CERTIFICATE OF INSERVICE INSPECTION

'\

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. S L 8 - 33 FORM NIS-2 OiVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/13/95 P. O. Box 529100 Sheet: 3 of 3 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A I A PCM ¹: 058-295 Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SA1A Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

TEE 8" X 8" X 6" TIOGA PIPE HEAT ¹ UTC 381931 A'

'B'D'R SA 234 WPB SUPPLY N07397 N/A RIR 22806 1995 MOD. NO FLANGE 6" TIOGA PIPE HEAT ¹ UTC371 232 A'

'B'D'R SA 105 SUPPLY 539 TNT N/A RIR 17907 1995 MOD. NO STUD 3/4"-1 OUNC2A ALLIED HEAT ¹ A'

'B'D'R SA 193 GR.B7 NUT & BOLT 91521 N/A RIR 1J-0091 1994 MOD NO STUD 3/4"-10UNC2A ALLIED HEAT ¹ A'

'B'D'R SA 193 GR.B7 NUT & BOLT 88147-GP N/A RIR 1 J4I043 1994 MOD NO STUD 3/4"-1 OUNC2A ALLIED HEAT ¹ A'

'B'D'R SA 193 GR.B7 NUT 8 BOLT 51122 N/A RIR 1H-1100 1993 MOD NUT, HEAVY HEX 3/4"-10UNC2B ALLIED HEAT ¹ UTC 373362 A'

'B'D'R SA 194 GR.6 NUT & BOLT N784D N/A RIR 22763 1995 MOD

PSL-1, NIS-2 TRACKING NO. S L 8 - 34 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS FPL As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/1 I/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. AIA PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8214
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012906-01 6501 South Hwy. A1A WCD ¹ 0198 Jensen Beach, FL 34957
4. (a) Identification of System CCW HX 2A & 2B Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VARIABLESPRING SUPPORT Expiration Date N/A (Mark Number) CC-2073-531 (c) Code Class: N/A (SUPPORT)
5. (a) Applicable Construction Code and Addenda: ANSI B31.1 1977 ED. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1973 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

VARIABLESPRING BERGEN PART ¹ SUPPORT 16VS PATTERSON BP-3100F-1 6 N/A N/A 1982 REPLACED NO VARIABLESPRING BERGEN PART ¹ UTC 377925 SUPPORT 16VS PATTERSON BP-3100F-16 N/A RIR 27324 1995 REPLACEMENT

7. DESCRIPTION OF WORK: DURING INSPECTION OF THE CCW, THE SPRING CAN WAS FOUND TO BE RUSTED AND CORRODED. ENGINEERING DETERMINED THAT IT SHOULD BE REPLACED DURING THE REFUELING OUTAGE.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) []

OF Other: VT1 [] VT2[] VT3 [X] PSIG Test Temp.

Hold Time

PSL-1, NIS-2TRACKING NO. S L-2 34 FORIN NIS-2 (Back) Sheet 2 of 2

9. Remarks FINALASSEMBLY INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
10. Inspection Report Numbers: M95-464 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date 19 AS Owners orOwnei's eslg e,TItle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Ownei's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property'damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. S L 8- 35 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL

1. Owner Florida Power & Light Co. Date: 12/11/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8212
3. Work Performed By: Florida Power & Light Co. WO ¹: 95020723-01 6501 South Hwy. A IA WCD ¹ Jensen Beach, FL 34957 0203'b)
4. (a) Identification of System CCW HX 2A & 2B Type Code Symbol Stamp N/A Authorization No. N/A Component Identification VARIABLESPRING SUPPORT Expiration Date N/A (Mark Number) CC-2073-441 (c) Code Class: N/A (SUPPOR'Q
5. (a) Applicable Construction Code and Addenda: ANSI B31.1 1977 ED. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1973 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

VARIABLESPRING BERGEN PART ¹ SUPPORT 15VS PATTERSON BP-3100F-1 5 N/A N/A 1982 REPLACED NO VARIABLESPRING BERGEN PART ¹ UTC 380514 SUPPORT 15VS PATTERSON BP-3100F-15 N/A RIR 29831 1995 REPLACEMENT

7. DESCRIPTION OF WORK: DURING INSPECTION OF THE CCW, THE SPRING CAN WAS FOUND TO BE RUSTED AND CORRODED. ENGINEERING DETERMINED THAT IT SHOULD BE REPLACED DURING THE REFUELING OUTAGE.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) []

Other: VT1 [] VT2[] VT3[X] PSIG Test Temp. F Hold Time

PSL-1, NIS-2 TRACKING NO. S L-2 35 FORM NIS-2 (Back) Sheet 2 of

9. Remarks FINALASSEMBLY INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
10. Inspection Report Numbers: M95-121 APPUCABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A signed Nk 25ciw Date (21 )l 19 IS Owners or OwneVS esig e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the OwneVs Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date L)~ tf

PSL-1, NIS-2 TRACKING NO. SL-2<- ~636 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/1/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucio Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: 009-293m
3. Work Performed By: Florida Power & Light Co. PWO¹: 3640 6501 South Hwy. AlA WO ¹: 94025062 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 8 Volume Control Type Code Symbol Stamp N/A V2462 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SECTI. III, 1971 ED; SUMMER '73 Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Rcpaircd or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N) 2 PISTON CHECK ROCKWELL NA SA 182 TP 316 1983 Replaced VALVE 2 PISTON CHECK ANCHOR DARLING 8/N E-T401-9-16 NA SA 351,CF 8M 1993 Replacement VALVE 2 SCH 160PIPE SANDVIK HT¹ 468341 NA SA 312, TP 304 NA Replacement VALVE-PIPE WELD FPL WELD TRAV¹ ER 308 1995 Replacement FW 2000 954225 VALVE-PIPE WELD FPL WELD TRAV¹ NA ER 308 Replacement FW 2001 954226 PIPE - TEE WELD FPL WELD TRAV¹ NA ER 308 Replacement FW-2002 954471

7. Description of Work: REPLACE VALVE DUE TO SEAT LEAKAGE. NEW WELDS ADDED FW 2000, 2001 & 2002 S/N E-T401-9-1 6
8. Tests Conducted: Hydrostatic Other. VT1 X

~ VT2 X Pneumatic VT3 Nominal Operating Pressure (ISLT)

~pstg Test Temp. ~'F

PSL-2, NIS-2 TRACKING NO. SL-2<- ~036 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A LIQUID PENETRANT EXAM AND HYDROSTATIC TEST WAS PERFORMED OF ALL WELDS.
10. Inspection Report Numbers: OST Hydro Rpt 11/10/95 APPLiCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the'rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed 0 er or

~ ~ p ibvr SLitov' ei's Designee, Title Z,I Date, c. I 19 ~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this OwneVs Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 nspectoVS Signature National Board, State, Providence and Endorsements Date 19~4.~

PSL-1, NIS-2 TRACKING NO. SL-2 ~83?

~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/25/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 082-193M
3. Work Performed By: Florida Power & Light Co. PWO¹: 8994 6501 South Hwy. A1A WO ¹: 94009303 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3523 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SECTION III; 1974 EDITION Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped Ol'eplacement Material (Yor N)

DISC ASSMEMBLY TARGET ROCK HEAT III NA SA 479- TP 316 1983 Replacement IG 4041

7. Description of Work: REPLACE DISC ASSEMBLY DUE TO SEAT LEAKAGE
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLTI

~pstg TestTemp. ~'P X

PSL-2, NtS-2TRADKtNG NO. SL-2 ~037 FORM NIS-2 (Back) Sheet 2 of 2 R s'eki3G&e- 7 wspsekoh R)~

9. Remarks: tt bg VTR 1 i+@~
10. Inspection Report Numbers: 0+QG-Q g+

APPUCABLE MANUFACTURES DATA REPORTS To BE ATTAciiED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner o ei's Designee, Title Go I/ LG( Date~art 2, 19~5

~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspectoi's Signature National Board, State, Providence and Endorsements Date 19'

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 082-193M
3. Work Performed By: Florida Power & Light Co. PWO¹: 7323 6501 South Hwy. A1A WO ¹: 93018650 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3551 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: ASME Sect III 1974 Ed / Sum 75 Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Y or N) sc em arget o ep ace Assembly TP 347 isc em arget o 0 2288 4 9 ep acement Assembly 0000352220 TP 347

7. Description of Work: Replaced disc/stem assembly due to seat leakage
8. Tests Conducted: Hydrostatic Other. VT1 VT2 Pneumatic VT3

~

Nominal Operating Pressure (ISLT) psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: PA~ Q6 ROE~

APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair +Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Au s< p<<w+ s ov. Date Qlv Q.tt 19 9-'0 ne Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

>r Commissions Inspector's Signature National Board, State, Providence and Endorsements Date 19 is

FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCESe Ae Required by the Provisions of the ASME Code, Section lil ~ g c~/4 Not to Exceed One Day's Production Pg.)of 2

. Manufacturedandcenlfledby Tar et Rock Cor . 1966E Broadhollow Rd; Farmingdale, NY 11735 (name and address ol IIPT Car(rica(a Ho(derl

2. Manufactured for Florida Power h Light Co.; Fort Pierce, FL 34954 Iname and address ot Purchase(I
3. Location of installation St. Lucie Plant; densen Beach, FL 34957 (name ahd addr ~ stl
4. Type:

204600-1 SA-479 347 75 ksi N/A 1994 (drawrns no.l (mat I. Soec. ho.l (tensile strehetht ICRNI (year oualtl 1974 Summer 1975 None

5. ASME Code,Section III, Oivision 1:

(adrtronl (addenda datal IC(asst (Code Case no,l N/A N/A N/A

6. Fabricated in accordance with Const. Spec. IOiv. 2 only) Revision Oate (no.l
7. Remarks:

Disc Spare part for valve model no. 75C-023 Part of Stem Assembly, P/N 200571-5

8. Nom. thickness (in.l Min. design thickness (in.l Oia. IO (ft (tt in.l Length overall (tt 8( in.)
9. When applicable, Certificate Holders'ats Reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No. Serial Number ~ Board No.

in Numerical Order in Numerical Order (1)

N/A (26)

N A (2) (27)

N A (28)

(3)

(4) l29)

(5) {30)

(6) (31) l7) l32)

(8) (33)

(9) {34)

{10) l35) l I II {36)

(12) {37)

(13) (38)

{14) (39)

(1 5) (40)

(16) (41)

(17) (42)

(I8) {43) l19) l44)

{20) (45)

(21) (46)

(22) {47) l23) (48)

(24) {49) l25) (50)

10. Oesign pressure F. Hydro. test pressure at temp. F (wtwn aooacso(el

'upplemental information in the form of lists. sketches, ot drawings may be used provided l1) sire is 8)) x 11. I2) lnfotmation in items 2 and 3 on this

~

i t Amb e n oats Repon i~ ktc(uded on each sheet. ~ I3) each sheet is numbered and the number of sheets is recorded at th ~ top of this form.

l12/88) This fohn (800040) may be obtained from the order oept.. AsM8. 22 Law orive.~ 8ox 2300.~ Faitfie(d.~ NJ 07007.2300.

Reprint pig 1)

PSL-1, NiS-2TRACKtNG NO. SL-2 ~039 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/25/95 P.O. Box 529100 Sheet: -

1 of Miam, FL 33152 Unit: 2

2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By Florida Power & Light Co. PWO ¹: 4906 6501 South Hwy. A1A WO ¹: 95025620 JensenBeach, FL34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A MV-08-1 B Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification or Stamped Material s Replacement (Yor N)

SEAL WELD FPL WELD TRAV.¹ NA SA-105 Replacement FW-2001 954246

7. Description of Work: REMOVE / REPLACE SEAL WELD TO FACILITATEVALVE REPAIR
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure ttSLT)

~psig Test Temp. ~'F X

PSL-2, NIS-2TRACKING NO. SL-2 039 FORM NIS-2 (Back) Sheet 2 of 2 9.Remarks: Q Qsska&r"WQ trtst-'re.'crhQrt >for 4'ski a/ra ~%5 p.rrttt)rtsse8 ~d ~IkcsseZ Q

a V~ g C~r4F ~8

10. Inspection Report Numbers: Iti/ii Q $ Q gQ g APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACKED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed SR I Sv/v- ISI Date kv ?S ta 'rr.

e or er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorsements Date rh 19 5i

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/2/95 P.O. Box 529100 Sllect' of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 1122 6501 South Hwy. AIA WO¹: 95019529 Jensen Beach, FL 34957 IA CWO ¹: NA Process Sheet: N/A
4. (a) IdentificationofSystem: MainSteam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V8211 Expiration Date N/A IdentiTication:

(Mark Number)

(c) Code Class: 2 ASME Section III 1989 Ed / No Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Yor N) net us aw ep ace 1 3/8 x 8 unc 2A Gr B7 n et tu s ovaMac ne eat o A 193 ep acement 1 3/8' 8 unc 2A 8868243/92397 Gr B7 net us aw 4 ep ace 1 3/8 x 8 unc 2B Gr2H n et uts A ie ut ot eat o 4 ep acement 1 3/8' 8 unc 2B Q2293A Gr7

7. Description of Work: Replaced inlet flange bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp.

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. InspectionReport Numbers: f8Ãg 5 c2 l I t APPLiCABLE MANUFACTURE'S DATAREPORTS TO BE ATl'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed J ~M P~~( GRr Owner r Owner's Designee, Title

- lGI D t~ t,19 ~+

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle C3 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/12/95 P.O. Box 529100 Sheet: 1 pf Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By.'lorida Power & Light Co. PWO¹: 2499 6501 South Hwy. A1A WO ¹: 95003094 Jensen Beach, FL 34957 CWO ¹: Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification: V8213 Expiration Date N/A (Mark Number)

(c) Code Class: 2

) APPlicable Construction Code and Addenda: ASME Sect III 1989 Ed/No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Cpde No. No. Identification Of Stamped OI'aterial Replacement (Yor N) n et ange tu aw ep ace 1 3/8 x Sun 2A Gr B7 n et ange tu ova eat o 88~93 ep acement 1 3/8 x Sun 2A 8868243/92397 Gr B7 n et ange ut aw ep ace 1 3/8' 8un 2B Gr2H n et ange ut Iie ut ot eat o ep acement 1 3/8 x Sun 2B Q2293A Gr7

7. Description of Work: Replaced inlet flange bolting due to corrosion
8. Tests Conducted: Hydrostatic Other: VT1 VT2 Pneumatic VT3

~

Nominal Operating Pressure (ISLT) pslg Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: fr< re i"-I g I G 8 5 APPLICABLE MANUFACTURE'S DATA REPORTS To BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed A.ne- v'- l<l Date MC I 3 19~5' Own r r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to,the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Ownei's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or toss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FP FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/5/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹: 1122 6501 South Hwy. A1A WO¹: 95019530 Jensen Beach, FL 34957 1A CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A V8207 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME Sect lii 1989 Edition / No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement PorN) u net aw ep ace 13/8'x8unc2A Gr 87 tu net ova eat o 93 ep acement 1 3/8 x 8 unc 2A 8868243/ 92397 Gr 87 ut net SPS2aw 194 ep ace 1 3/8 x 8 unc 28 Gr7 ut n et Ahe ut ot eat o 94 ep acement 1 3/8 x 8 unc 28 Q2293A Gr7

7. Description of Work: Replaced inlet flange bolting
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp.

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: 'W Glic2- i ~~

APPLiCASLE MANUFACTuRE'S DATAREPORTS To SE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Gk arRIi WM IN(

n ror n r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, Nls-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power &, Light Co. Date: 11/27/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By Florida Power & Light Co. PWO¹: 5002 6501 South Hwy. A1A WO¹: 95028509 Jensen Beach, FL 34957 1A CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A V8201 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME Sect III 1989 Edition/no addenda Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N) u ne ange aw ep ace 1 3/8 x 8 unc 2A Gr B7 u n et ange ie u ot eat os ESK705 ep acement 1 3/8 x 8 unc 2A 8868243/92397 Gr B7 ut n et ange aw 94 ep ace 1 3/8 x 8 unc 2B Gr 2H ut n et ange ie u ot eat o ep acemen 13/8xaunc2B 02293A Gr7

7. Description of Work: Replaced inlet bolting.
8. Tests Conducted: Hydrostatic Other: VT1 VT2~

Pneumatic VT3

~

Nominal Operating Pressure (ISLT) pslg Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: N/tn I 6 APPLICABLE MANUFACTuRE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of A thorization No.: N/A Signed o Ge (. WSuW 5 D t QOV~,19'K Owne Ow e s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions tnspectoi's Signature National Board, State, Providence and End orsements Date ILiOV' > , 19~5

PSL-1, NIS-2 TRACKING NO. SL-2 I FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/12/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By Florida Power & Light Co. PWO¹: 2511 6501 South Hwy. A1A WO¹: 95002850 Jensen Beach, FL 34957 1A CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification: V8208 Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME Sect III 1989 Ed/No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. identification or Stamped Material Replacement (Y or N) n et ange tu aw A ep ace 1 3/8 x 8un 2A Gr B7 n et ange tu ova eat o 93 Rep acement 13/8 x8un2A 8868243/92397 Gr B7 n et ange ut aw A ep ace 1 3/8 x 8un 2Blnlet Gr2H ange u ie Ut ot eat o 94 ep acemen 13/8 x8un2B Q2293A Gr7

7. Description of Work: Replaced inlet flange bolting due to corrosion
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

VT.3 Test Temp. LF Other: VT1 VT2 psig

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATfACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Sri PCA Soot/- IS CeIe~llZ, Ie 'RS n r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle P8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. S L 8- 45 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI

1. Owner- Florida Power & Light Co. Date: 12/18/95 P. O. Box 529100 Sheet: 1 of 3 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: 016-290 Jensen Beach, FL 34957 NPWO ¹: 8882
3. Work Performed By: Florida Power & Light Co. WO ¹: 95024868-01 6501 South Hwy. A1A WCD ¹: 0242 Jensen Beach, FL 34957
4. (a) Identification of System CCW HEAT EXCHANGER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 2A SHELL SIDE DRAIN Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition

'b)

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

FLANGE"S/0 TIOGA PIPE HEAT ¹ UTC 380442 2A HX SA 105 150¹ SUPPLY 8861721 N/A RIR 29303 1995 DRAIN MOD. NO PIPE -6" TIOGA PIPE HEAT ¹ 2A HX SA 106 GR. B SUPPLY 33366 N/A RIR 3RB-1677 1990 DRAIN MOD.

FLANGE%"BL TIOGA PIPE HEAT ¹ UTC 3825939 2A HX SA 105¹ SUPPLY 8079587 N/A RIR 31617 1995 DRAIN MOD.

7. DESCRIPTION OF WORK: EXISTING DRAINS WERE DEGRADED AND INEFFECTIVE.

MODIFICATIONWAS COMPLETED TO INCREASE EFFECTIVENESS.

8. Test Conducted: Hydrostatic [X ] Pneumatic [] Nominal Operating Pressure (ISLT) []

Other: VT1 [] VT2[X] VT3 [] 165 PSIG Test Temp. SYSTEM F Hold Time 10 MINUTEs

PSL-1, NIS-2TRACKING NO. S L-2 45 FORM NIS-2 (Back) Sheet 2 of

9. Remarks A HYDRosTATIG PREssURE TEsTwAs succEssFULLY PERFQRMED QN THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
10. Inspection Report Numbers: . M95-307 APPLICABLE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the reportare correct and this [ ] Repair [ ] Replacement

[ X ) Modification conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Date De< ~4, 19 ~S OwnersorOwn SDes nse, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle P8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

xl PSL-2, NIS-2TRACKING NO. S L-2 45 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.,Owner Florida Power & Light Co. Date: 12/13/95 P. O. Box 529100 Sheet: 3 of 3 Miami, FL 33152 Unit: 2

2. Plant St. Lucie Nuclear Plant P.O. 8: N/A 6501 South Hwy. A1A PCM ¹: 016-290 Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SA1A Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. Replacement (Yor N)

STUD 3/4" 10UNC2A ALLIED NUT HEAT ¹ 2A HX SA 193 GR.B7 AND BOLT 51122 N/A RIR 1H-1100 1995 DRAIN MOD.

NUT, HEAVY HEX 3/4" 10UNC28 ALLIED NUT HEAT ¹ UTC375495 2A HX SA 194 GR. 2H AND BOLT E04277 N/A RIR 25731 1995 DRAIN MOD. NO

PSL-1, NIS-2 TRACKING NO. S L 8 - 46 FORM Ii/IS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMEi ITS PPL As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: I I/13/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A IA PCM¹: N/A Jensen Beach, FL 34957 NPWO ¹: 7706
3. Work Performed By: Florida Power & Light Co. WO ¹: 95013850-01 6501 South Hwy. A1A WCD ¹: 0184 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVEV-21165 Expiration Date N/A (Mark Number)

(c) Code Class:

5. (a) Applicable Construction Code and Addenda: ASME 1977 S 1977 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identi6cation of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

NUT, HEAVY HEX ALLIEDNUT RIR 2J-1 002 1 1/2"%UN 2B AND BOLT SA194GR.7 REPlACEMENT NO NUT, HEAVY HEX ALLIEDNUT RIR 26598 1 1/2"%UN 2B AND BOLT Q2293A SA 194 GR. 7 REPLACEMENT NO NUT, HEAVY HEX ALLIEDNUT RIR 2H4253 1 1/2"%UN 2B AND BOLT Q2293A SA 194 GR. 7 1993 REPLACEMENT NO NUT, HEAVY HEX ALLIEDNUT RIR2J-1243 1 1/2"NUN 2B AND BOLT Q2293A SA 194 GR. 7 REPIACEMENT NO BOLT, STUD ALLIEDNUT RIR 26597 1 1/2"4UNX61/2" AND BOLT 52869-FC N/A SA 193 GR. B7 1995 REPlACEMENT NO

7. DESCRIPTION OF WORK: BOLTING WAS WORN DUE TO NORMALWEAR AND TEAR AND FPL RECOMMENDED REPlACEMENT
8. Test Conducted: Kydrostatic [] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other. VT1 [] VT2[X] VT3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 46 FORM NIS-2 (Back) Sheet 2 of

9. Remarks IsLT wAs sATIsFAGToRILY PERFQMED oN YALYEsB-21165
10. Inspection Report Numbers: M95-308 APPLICABLE MNrUFACTURER'S OATA REPORTS To BE ATTACIKD Certificate of Compliance We certify that the statements made in the report are correct and this [ ) Repair f X ) Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date LL Owners or s De nee, TIUe CERTIFICATE OF INSERVlCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bo6er and Pressure Vessel inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any wananty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-1 NIS-2 TRACKING NO. S L 8 -

~ 47 FORiM NIS-2 OIVlAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 11/13/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: 129-295 Jensen Beach, FL 34957 NPWO ¹: 8779
3. Work Performed By: Florida Power & Light Co. WO ¹: 95024463-01 6501 South Hwy. A I A WCD ¹: 0236 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification LINE I-24"-CW-75 Expiration Date N/A (Mark Number) 24" ELBOW (VALVESIDE) ICW "A" HEADER (c) Code Class: 3
5. (a) Applicable Construction Code and Addenda: ASME 1977 S 1977 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Repaired or Stamped Material No. No. Replacement (Yor N)

UTC 378384 BOLT, STUD ALLIED SA 193 GR. B7

'1 1/4"WX51/2 NUT & BOLT M53716 RIR 27708 REPLACEMENT NO BOLT, STUD UTC 379705 1 1/4"WUN2AX13 ALLIED SA 193 GR. B7 CUT FROM ROD NUT & BOLT 62413 N/A RIR 2J<232 REPLACEMENT NO UTC 333268 NUT, H. HEX ALLIED SA 194 GR. 2H 1 1/4" WUN2B NUT & BOLT E97187 RIR 2J<761 REPlACEMENT NO

7. DESCRIPTION OF WORK: STUDS AND NUTS WERE REPLACED BECAUSE THEY WERE NICKED AND WORN DUE TO NORMALWEAR AND TEAR.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other. VT1 [] VT2[X] VT3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HDURs

PSL-1, NIS-2 TRACKING NO. S L 8 - 47 FORNI NIS-2 (Back) Sheet 2 of

9. Remarks ISLT WAS SATISFACTORILY PERFOMED FOR THE FLANGE TO VALVE CONNECTION AT VALVE I-MV-21-3.
10. Inspection Report Numbers: M95-306 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed W~W Date ('L I IS 19~X Owners or er's ignee, TiUe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engineering Associates have inspected the components described in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my knowledge and belief, the Ovmer has performed examinations and taken corrective measures descnbe in this Owner's Report in accordance viith the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2TRACKING NO. S L-2>>8- 48 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/18/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. AIA PCM ff: N/A Jensen Beach, FL 34957 NPWO ¹: 8210
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012782-01 6501 South Hwy. A IA WCD ¹: 0195 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification SB 21163 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

BOLT, SA 193 GR.B7 HEAT ¹ UTC 341998 1 1/4"-SUN2AX7" NOVA MACHINE 79916 N/A RIR 3J-1052 1994 Replacement NO BOLT, SA 193 GR.B7 HEAT¹ UTC 341991 1 1/4"SUN2AX20 NOVA MACHINE M51 481 N/A RIR 3J-1052B 1994 Replacement NO NUT, HEAVY HEX SA 194 GR. 2H ALLIED NUT HEAT¹ UTC 374489 1 1/4-8UN2B AND BOLT CO. 151593 N/A RIR 24742 1995 Replacement NO

7. DESCRIPTION OF WORK: BOLTING AT VALVE21163 REPLACED BECAUSE OF NORMAL WEAR AND TEAR
8. Test Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure (ISLT) [X ]

Other: VT1 [] VT2 [X] VT3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 -59 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN IsLT wAs sUGGEssFULLY PERFQRMED QN THE FLANGED CONNECTIONS AND WITNESSED BY A CERTIFIED Q.C. INSPECTOR
10. Inspection Report Numbers: M95-302 APPLICABLE MANUFACTURER'S OATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair t X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Owners or Own s DB I nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel

, Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP As Required by thc Provisions of the ASME Code Section XI I. Owner: Florida Power & Light Co. Date: 12/13/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit:

2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power Er, Light Co. PWO¹: 3572 6501 South Hwy. A1A WO ¹: 95001866 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdentificationofSystem: ComponentCooling Water Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification: SS-21-1A Expiration Date N/A (Mark Number)

(c) Code Class: 3 (a) Applicable Construction Code and Addenda: ASME Sect lli / 1989 Ed No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification or Stamped Material Replacement (Y or N) u s um 193 ep ace 1 -Suncx 7" Industries Gr B7

~iu s ova eat o 193 ep acement 1 -Suncx 7 Machine S090323 Gr B7

7. 'escription of Work: Replaced strainer studs due to normal corrosion.
8. Tests Conducted: Hydrostatic Other: VT1 VT2 Pneumatic

~ VT3

~

Nominal Operating Pressure (ISLT) psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MM95-1395 8 MM95-1918 APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed SP V/ L/ l5 Date ~l(819~7, ner o nei's Designee, Title CERTIFICATE OF. INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle P8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date /3, 19~

PSL-1, NIS-2TRACKING NO. S L-2 50 FORM NIS-2 OWVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 01/18/96 P. O. Box 529100 Sheet: I of 4 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A IA PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8218
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012801-03 & 04 6501 South Hwy. AIA WCD ¹: 0188, 189, & 0190 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification LINE I-30-CW-20 Expiration Date N/A (Mark Number) SPOOL 14 ZiV-68-I Ec 2 EL 1-30"-CW-77-2 (c) Code Class: EL I-30 CiV-76-2
5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section Xl for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

NUT,HH-SA-194 ALLIED NUT HEAT ¹ UTC 333268 1 1/4"-8UN2B AND BOLT E97187 N/A RIR 2J-0761 1994 REPLACEMENT NO BOLT, SA 193 ALLIEDNUT HEAT ¹ UTC 373936 1 1/4"4UN2AX9" AND BOLT 8894177 N/A RIR 24401 1995 REPLACEMENT NO BOLT, SA 193 ALLIED, NUT HEAT ¹ UTC 331564 1 1/4"-8UN2AX9" AND BOLT 70251 N/A RIR 3J-0190 1994 REPLACEMENT NUT,HH-SA-194 ALLIED, NUT HEAT ¹ UTC 374489 1 1/4"-8UN2B AND BOLT 151593 N/A RIR 24742 1994 REPLACEMENT NO

7. DESCRIPTION OF WORK: MATERIALSWORN DUE TO NORMALWORN, TEAR AND CORROSION.

FPL RECOMMENDATIONTO REPLACE

8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other: VT1 f] VT2[X] VT3 [X] SYSTEM PSIG Test Temp. SYSTEM F Hold Time 4 HoURs

PSL-1, NIS-2TRACKING NO. S L-2 50 FORM NIS-2 (Back) Sheet 2 of 4

9. Remarks ISLT WAS SATISFACTORILY PERFORMED FOR THE FLANGED CONNECTIONS.

FINAL INSPECTION WAS PERFORMED FOR SUPPORT BY A VT3 CERTIFIED INSPECTOR.

10. Inspection Report Numbers: M95-411, M95452, 8 M95-454 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair f X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorizati No N/A Signed Date ners or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

'By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. S L 8 - 50 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 01/18/96 P. O. Box 529100 Sheet: 3 of 4 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. I/: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SAIA Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

BOLT-SA193 HEAT¹ UTC 375439 5/8"-1 1UNC2A NOVA MACHINE 6R-59444 NIA RIR 25175 1995 Replacement NO NUT,HH -SA194 ALLIEDNUT HEAT ¹ UTC 374489 1 1/4"-8UN2B AND BOLT 151593 NIA RIR 24742 1995 Replacement NO NUT, HH- SA194 ALLIEDNUT HEAT ¹ UTC 374486 1 1/8"4UN2B AND BOLT 152550 NIA RIR 24742 NIA Replacement NO U-BOLT A36 WI U-BOLT HT.¹ A563 GR.A NUT BERGEN 8096325 UTC 373874 2 1/2" PIPE SIZE PATIERSON NUTS-3D589 RIR 3AH4375 1993 Replacement NO NUT, HH- SA194 ALLIEDNUT HEAT ¹ UTC 375497 5/8"-11UNC2B AND BOLT L63812 NIA RIR 25731 1995 Replacement BOLT- SA1 93 HEAT ¹ 5/8"-1 1UNC2A NOVA MACHINE 62477 N/A RIR 1 J4199 1994 Replacement NO BOLT- SA193 HEAT ¹ UTC 372561 5/8"-1 1UNC2A NOVA MACHINE 62477 N/A RIR 1J4224 1994 Replacement NO BOLT- SA193 HEAT ¹ UTC 375439 5/8"-1 1UNC2A NOVA MACHINE 6R-59444 N/A RIR 25175 1995 Replacement NO BOLT- SA193 ALLIED NUT HEAT ¹ UTC 372557 5/8"-11UNC2A AND BOLT 88147-GP N/A RIR 1 J-0247 1994 Replacement NO BOLT- SA193 ALLIED NUT HEAT ¹ UTC 374493 5/8"-11UNC2A AND BOLT 88147-GP N/A RIR 24742 1995 Replacement NO BOLT- SA193 ALLIED NUT HEAT¹ UTC 331566 1 1/4"-8UNC2A AND BOLT 70251 N/A RIR 3J-0190B 1994 Replacement NO BOLT- SA193 ALLIEDNUT HEAT ¹ UTC 331565 1 1/4"-8UNC2A AND BOLT 8078593 NIA RIR 3J-0190A 1994 Replacement NO BOLT- SA193 ALLIEDNUT HEAT ¹ UTC 331567 1 1/4"-8UNC2A AND BOLT 62480 NIA RIR 3J4190B 1994 Replacement

PSL-2, NIS-2 TRACKING NO. S L-2 50 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS FPL As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 01/18/96 P. O. Box 529100 Sheet: 4 of 4 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM¹: N/A Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SA1A Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

FLANGE, 4" SA 105 N/A N/A N/A N/A N/A Replaced NO FlANGE, 4" HEAT ¹ UTC 378328 SA 105 TIOGA PIPE 8860283 N/A RIR 27287 1995 Replacement NO PIPET, 30"X4" SA 234 N/A NIA NIA NIA NIA Replaced NO PIP ET, 30"X4" HEAT CODE SA 234 TIOGA PIPE 71 N/A RIR 2J4292 1994 Replacement NO SUPPORT CW-3001437 A36 (ANGLE) NIA NIA N/A N/A N/A Replaced DUBOSE ANGLE, A36 NATIONAL HEAT ¹ UTC 369804 3" X3" X3/8" ENERGY J5966 N/A RIR 3AK4606 1995 Replacement SUPPORT CW-3001437 A36 (ANGLE) N/A NIA NIA NIA N/A Replaced DUBOSE ANGLE, A36 NATIONAL HEAT ¹ UTC 370160 1 1/2"X1 1/2"X1/4" ENERGY J2705 NIA RIR3AK4617 1995 Replacement NO

PSL-Q NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3601 6501 South Hwy. A1A WO ¹: 95001741 Jensen Beach, FL 34957 CWO ¹: Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No. N/A (b) Component PCV-1100F Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 1 a) Applicable Construction Code and Addenda: ASME Sect III 1971 Ed/W72Add. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification of Stamped Material Replacement (Y or N) ug stem is er ontro s 4 ep ace Assembly Typ 316 ug stem is er ontro s eat o A 4 9 199 Replacement Assembly 99911-1 Typ 316

7. Description of Work: Replaced plug and stem assembly due to normal wear.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: cf Q APPLicABLE MANUFACTURE'S DATAREPORTS TO BE ATl'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair Q Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed kA Own

'e GS ndnn 5vnv r Owner's Designee, Title Date ~0~+7, 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the'Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2TRACKING NO. S L-2 52 FORM NIS-2 OYVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/07/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: C92933-90719 6501 South Hwy. AIA PCM¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8234
3. Work Performed By: Florida Power & Light Co. WO ¹: 95028726-01 6501 South Hwy. AIA WCD ¹: 'N/A Jensen Beach, FL 34957
4. (a) Identification of System CCW SUPPLY HEADER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVESB14528 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1974 S 1974 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

HENRY PRATT SA516 VALVE- 10" CO. D 0065-2-1 N/A GR. 70 N/A REPLACED YES UTC 383726 HENRY PRATr SA 516 GR. 70 VALVE- 10" CO. DD74-1-1 N/A RIR 3H-0911A 1993 REPLACEMENT YES

7. DESCRIPTION OF WORK: PLANT WAS UNABLE TO TIE-IN PER PCM 058-295 (PERM. CONT. A/C)

VALVEWAS LEAKINGAT THE SEAT AT A RATE OF 2 GAL.PER MINUTE.

8. Test Conducted: Hydrostatic [ ] Pneumatic [] NominaI Operating Pressure (ISLT) [ X]

Other: VT 1 [] VT 2 [X ] VT3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 52 FORM NIS-2 (Back) Sheet 2 of

9. Remarks ISLT FOR THE FIANGED CONNECTIONS ON VALVESB-14528 WAS SATISFACTORILY PERFORMED.
10. Inspection Report Numbers: M95-467 APPUCAB LE MANUFACTURERS DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair f X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: NIA Certificate of Authorization No N/A Owners or Owner's D ignee Ie Date >2 I 7, ttt~f.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ff8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and

'taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or toss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date 196 V

) p gQ-o t II Page < ot ~(

FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORTS-0 R PUMPS OR VALVES As Required by the Provisions of the ASME Code.Section III. Division 1 Pg. of

1. Manufactured and cenrfied by HENRY PRATT COMPANY T V Iname and address ot N Canrhcate Holder)
2. Manutactured for FLORIDA POWER AND LIGHT (name and address ot Parcnaser or ownen
3. Locauon of installation ST. LUCIE UNIT 2 (name and address)
4. Model No.. Series No. or Type

~ Drawing N/A Rev. N/A CRN N/A

5. ASME Code. Section Ill, Division 1: 1974 SUM 74 3 N/A (edmon) Iaddenda dater Idassi (Code Case no.)

VALVE 10

6. Pump or valve Nomina( inlet size 0 detsize (in.) lin. I 7 Mat r,-ai. SA516 GR70 Bonnet SA351 CFSM Bolting SAl GR8 Br)d Disk (al (bl (cl (dl (el Cen. Nat'I Body Sonnet Ois((

Holder's Board Serial Serial Serial Serial No. No. No, No. No.

N A 802H41790 N/A T180-802H41790 N/A T18 -4

'Supplemental intonnation in form of rists. sketches, or drswines mav be used provided (1) size is 8)( x 11. 121 Information in items I through 4 on this oats Repon is induded on each sheet, (3) each sheet is numbered and the number of sheets is recorded st the top of this form.

() 2JB()) This form (E00037) may be obtained from the Order Oept., ASME, 22 Law orivesos 2300. Faireeld. NJ 07007.2300.

lR ~ ~ I 20F2 page~et 0074 FORM NPV-1 (kcckl B. Remarks

9. Design conditions psi 200 4F or valve pressure class (pressurel ttemoereturer 1
10. Cold working pressure 285 psi at 1004F
11. Hydrostatic test 450 psi. Disk differential test pressure 165 psi CERTIFICATION OF DESIGN Design Spectfication cerufied by P E State FL R 13797 Design Report certified by KE I TH LB% P.E. State

.gP CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this re pon are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section lli, Division 1.

N1030 Expires N Certificate of Authorization No.

Date~" I< '7~ ame Signed (N Cert>fkeste Holdert (eutnonte eseotsuvet CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by of have inspected the pump, or valve, descnbed in this Oats Report on

-I , 19 ~~. and state that to the best of my knowledge and belief, the Certtflcate Holder has constructed this pump. or valve. in accordance with the ASME Code,Section III, Division 1.

By signing this certificate.'eithor the inspector nor his employer makes any warranty, expressed or implied. concerning the manner for component described in this Data Report. Furthermore, neither the inspoctor nor his employer shall be liable in any any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 3'- r~.,'+ Signed ~ opted I pector>

w Commissions

' >5 Xf-I (Net'I. Bd. lied. endorsernents) state or prov. snd no.l I1) For manually operated valves only.

PSL-1, NIS-2TRACKING NO. S L-2 53 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL

1. Owner Florida Power & Light Co. Date: 12/07/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.o.f/: C92933-90719 6501 South Hwy. A1A PCM f/: N/A Jensen Beach, FL 34957 NPWO ff: 8234
3. Work Performed By: Florida Power & Light Co. WO //: 95028735-01 6501 South Hwy. A1A WCD //: 'N/A Jensen Beach, FL 34957
4. (a) Identification of System CCW SUPPLY HEADER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVESB14530 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1974 S 1974 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

HENRY PRATI SA516 VALVE- 10" CO. D44725-8-1 N/A GR. 70 N/A REPLACED YES UTC 383729 HENRY PRATT SA 516 GR. 70 VALVE- 10" CO. 0D74-1-2 N/A RIR 3H-0911B 1993 REPLACEMENT YES

7. DESCRIPTION OF WORK: PLANT WAS UNABLE TO TIE-IN PER PCM 058-295 (PERM. CONT. A/C)

VALVEWAS LEAKINGAT THE SEAT AT A RATE OF 2 GAL.PER MINUTE.

8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other: VT1 [] VT2[X] VT3 [] sYSTEM PSIG Test Temp. SYSTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 FORIN NIS-2 (Back) Sheet 2 of

9. Remarks ISLT FOR THE FLANGED CONNECTIONS ON VALVESB-14530 WAS SATISFACTORILY PERFORMED.
10. Inspection Report Numbers: M95-466 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Owners or Owner'slg e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date 19~>

)R g]4-oq f(

Page < ot ~(

FORM NPV-1 CERTIFICATE HOLDERS'ATA REPORT% R PUMPS OR VALVES As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of

1. Manufactured and certified by HENRY PRATT C(NPANY 00 T A tname and address ot N cernricate Hoideri
2. Manufactured for LO IDA PO~R AND LIGHT (name and address ot Parcnaser or owneri
3. l.ocahon of installation ST>> LUC I E UNIT 2 (name and addiessi
4. Model No.. Series No.. or Type Orawing N/A Rev N/A C((N N/A
5. ASME Code,Section III, Oivision 1:

1974 SUM 74 3 N/A (editionl taddenda cater Icrassr (Code Case no.i VALVE 10tr t nit

6. Pump or valve Nominal inlet size Outlet size (in.l lin. I 7 M t nal Bod Bonnet (al (b) (c) (d) (el Cen. Nat'I Body Bonnet Oisk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

N A 802H41790 N/A T18 N A 802H41790 N/A T18 -4

'supplemental information in term ot asts. sketches, or drawings may be used provided (1) size is 8)) x 11. (21 information in items 1 through 4 on this oats Report is indud<<d on each sheet, l3) each sheet is numbered and the number ol sheets is recorded at the top of this form.

112/88) th(s form (E00037)may be obtained from the order oept.. ASME, 22 taw Drive. 8ox 2300. Fair eield. N3 07007-2300.

la ~ -~~~~

20F2 psife~of FORM NPV-1 (back)

DD7".

8. Remarks
9. Oestgn conditions psj 200 eF or valve pressure class ipressure> itempcrsturer
10. Cold working pressure 285 psi at 1004F
11. Hydrostatic test psi. Oisk differential test pressure 165 psl CERTIFICATION OF OESIGN Reg. no.

Oesign Specification certified by Oesign Report cartigred by KE I TH L P.E. State P.E. State RI< o.~~M'p o qP CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code.Section III. Division 1.

N Certificate of Authorization No.

N1030 Expires Oste ~" ~~ ~~ arne Signed IN Cenrricste Holder> leutnonze esentstrver CERTIFICATE OF SHOP INSPECTION I~ the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and n

the State or Province of and employed by ot have inspected the pump, or valve. descnbed in this Oats Report on

- /

, 19 ~~. and state that to the best of my knowledge and belief. the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III. Oivision 1.

By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or implied. concerning the component described in this Oats Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Oats 2-rg.. '+ Signed nzed I peer pn Commissions

' )K ZLf INet'I. Bd. (ind. endorsementsi state or prov. snd no.l l1)For manually operated valves only.

, PSL-1, NIS-2 TRACKING NO. SL-2 054 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F ~

As Required by the Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/2/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 8801 6501 South Hwy. A1A WO ¹: 94007594 JcnscnBeach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Containment Spray Type Code Symbol Stamp N/A V07120 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 ASME SEcnoN III 1986 EomoNNo AoosNoA Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Rcplacemcnt Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component or Manufacturer Serial or Heat Board IdentiTication Built Repaired Code Material No. No. or Replacement Stamped Yor Flange Stud BF Shaw NF NA SA 193 NA Replaced N) N 1 1/4' 8 unc Gr B7 Flange Stud Allied Nut & Bolt Heat No SA 193 NA Replacement N 1 1/4' 8 unc 90755/TR N 27 Gr B7

7. Description of Work: Replaced flange stud due to damage.
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3

'ominal Operating

~pstg TestTemp. ~'F Pressure (ISLT) X

'heet PSL-2, NIS-2 TRACKING NO.

FORM NIS-2 (Back)

SL-2N-2 of 2 054

9. Remarks: A satisfactory Inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MM95-1 524 APPUCABLE MAMUFAOTURES OATA REPORTS To BE ATfACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Owner o l4 .S L rt s Designee, Title Wpv Date It ~ 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. S L 8- 55 FORM YiIS-2 OIVtAVERS REPORT FOR REPAIRS OR REPLACEIilENTS J As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 11/17/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O.//: 88929-92668 6501 South Hwy. A1A PCM I/: N/A Jensen Beach, FL 34957 NPWO //: 8210
3. Work Performed By: Florida Power & Light Co. WO 0: 95012782-02 6501 South Hwy. A1A WCD f/: 0197 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVEV-21162 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1977 S 1977 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

TRW MISSION TAG I-V-21 678 SA216 VALVE- 30" VALVECO. FIG. 15-SNF-921 GR. WCB N/A REPLACED UTC 349242 SA 216 C&S VALVE 89G213801- GR. WCB VALVE- 30" COMPANY Z0663 RIR 3J-1375 1995 REPLACEMENT YES

7. DESCRIPTION OF WORK: DURING INSPECTION, M/M SUPV. DETERMINED THAT THE VALVE NEEDED TO BE REPLACED.
8. Test Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other. VT1 [] VT2[X] VT3 [] SYSTEM PSIG Test Temp. SYSTEM F Hold Time 4 HQURs

PSL-1, NIS-2 TRACKING NO. S L-2 55 FORM NIS-2 (Back) Sheet 2 of

9. Remarks ISLT FOR THE FLANGED CONNECTIONS ON VALVEV-21162 WAS SATISFACTORILY PERFORMED.
10. Inspection Report Numbers: M95-301 APPUCAIRE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X J Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date >~l11 Owners or Owne Des nee, TrUe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components descnbed in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my krewledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

I By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concemlng the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

FORM NPV-1 CERTlRCATE HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR VALVESe Ae Required by the Provlelone of the ASME Code, section ill. Division 1 Pg. 1 of

  • , , .GLS Yalve Co., Mzlear Products Div.; 40 ~i~t Ave.; Westmont, lL 6K

~

1. Manufactured and cert(f(ed by (nsn(s snd sddtsss of Csn(nests N Hc(dsr(

3 Location of installation Flori~

1Ori+ ~

g, Li~ QzPai1y; P.Q. KN 12S; Fort Pierce. Florida 34954

~ Light Ca (nsms t +

snd address

~ie of

~

purchaser} .

6501 RUUl A1A; (hsme snd sddfs ss(

~ Heach, Florid Model NoSeriea Noor Zype Dual Plate g(,;~ 94-2PM1 N R

A gg N/A Ennea 1%4 3 N-133-1

5. ASMB Code.Section III, Oh(alon 1

~

(ed(t(onl (addenda cats) (c(ass( (Cods Case no.)

d. pumper vahe Nominal inlet aix X" Outlet aixe
7. Material: Body Bonnet (In.l ol,m (Plate 148 e. m (in.l

~, See ~ Side ia) ib) ic) id) ie)

Cert. Nat'I Body Bonnet Oia)(

Holder's Board Ser(al Ser(al Serial Serial No. No. No. No. No.

'voo(smenta( information in form of asts, snatches. or drawings may he used provided l1) s(te is 1% x 11, l2) infonnaoon in items 1 through i on th(>> osta ftsoort la inc(uded on sech sheet. (2) sech sheet is numbered snd the numosr of sheets is rscordeo at the too of th(s form.

(12/88) TNs ream (axe37) may be o~ fm the order oeot.. idML 22 ta 0~. do* 2200. Faeee. M 0700T 2200 as ~~~~

  • 8(xty manufactured by CSS Yalve mhr F89-0606(Nl. ~

M 0 89-05K?41(N)-01.

i ~libby Fl~e Plates manufactured by QS Yalve F) aLi~.

g'g-z -p- 05+

g ZJ-IVVS-P ~ t cs FORM NPV-1 t Back Pg. 2 of )

Certificate Holder's Senal ffo. 8 6 2<1(N)<1

$ . Design conditions psj 100 eF or vsl ~ pressure class ipreaeurel iternpereturel

9. Cold working pressure
10. Hydrostatic test psi. Disk differential teat pressure 1 1 pal
11. Remarks:

CHlTIFICATIONOF OKSIQN Design Specificadon certified by P.E. State ~~+ R~~. ~>

Design Report cartified by P.E. State Raga now CEllTIFICATIOF COMPUANCI We certif that the statements made in this report ar ~ correct and that this pump or valve conforms to the rules for construction of the ASM'ode,Section III, Division I.

N Certificate of Authorlxadon No. 6/20/95

, C5S Valye CO. Re. ~~

W Ceroficete Holderl DiV. SI~ Iwtnorieed representsdvel CSmFICATI OF IN4$%CTlON I. the undersigned. holding a valid commission issued by the National Board of Boger and Pressure Vessel In ors and the State or Province of and employed by of have inspected the pump, or valve. described in this Data Report on

~ and state that to the best ot my knowledge and begef the Certificate Holder has con structed thfa pump. or valve. in accordance with the AS ME Code, Secdon ill, Division 1.

By signing thfa certitlcat>>. neither the inspector nor hla employer

+F tbtual ineeriw Associatian or implied. concerning the any , axprea component deacrfbed ln this Oat>> Report. Furthermore, neither the inspector nor hfa employer shaw be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with thfa inapecdon.

Frp O ~ + Signed I 'n orl chal Iffet'I.ad. finer. endoreeroentsi end ststeorprov. endno.l l 1) For manually operated valves only.

k((ILI larV.I I( ~II>> v<<>>I ~ ~.

-7'!

Aa Roe) r(red by. t)to Boo{alone cf the ASN% Sect)on N, ()br.

(>>I, 1

~ 5 '>> 4' I OfVfsiCn'.40 Cheart AVe. 'MSStmat, IL 6Q559-11%

'l  ; 1(, )4AAltaured by

~ I 0: ltanuaectured lor Shach 'laridi"BI%8-1m or fvweee w

(

L Locedon d ~

~~ g

'-'i4, Aae0 or Viho Inch)

~ ~ ~

(a) Mode{ No (b) )t Cert(Acate HOMar's No' " "'.:. 0er{al.;- Reglatret(on ~ 'd) Drawing'," . * ~ . ~,", (() Nat'I. ~

(0) Year or Type' Ho, .>>". No.". ". No. - {e) CIaae . ed. No. ~; e~

(

h 1%g

{a) ~

{10)

~ r Olsf eaacneoon or Sanaca fer ~

~

'% '.". "':;-')'-

~

L 'p or Valve heaaure

~ 4 Cold Wore)ny Procure

~

Pressure {tete(ning tleeee1 IFtsA 1 '

~

'pal et 10M '. ':

ogpg+gai

~,

~ (4 A

.'.'>>, II

~ ~

Mater{a( Spec. No. Nawfacturer I

(e)

~

S-.

~ ~

~

{b) Forylnye ~

qual>>'

'l) t ~

~

' tot meweiy operated valse on)y.:,':, i."

' Nupplemental aheeta ln terri ol )lath ebeaciee or draw(neo mey be used yeekSe) (1) a{ac le 4'lO' 11; N) (rv)orrnetlon ln

~ )tome 1 0 and 5 on d(e octa ((aport le inctuded on each sheet, and 0) each sheet le numbered and number ot eheeta

~

le retorded at tetr oi this form. ~ ~~ ~

  • llew ierrrt {SCPj hwr ae eitaawd

~ ~

'I

.".. {14Nl Ir r ~ '. O'er OaotANt,0' rjorn the

~, rr>>>>eL y~I ~ + Pl~>>r CO 0t (r

New VeA, N Y. 10011

~qayq .i~>> r ' - > ~

Yc'i i'aQe )Je , Ieaaatlel Qyec. HO.

~

V

,tq

~ r+

,r '

'4 ~

~ ~

.(, ~

,I ~

'Q 4

4 IILLIILIL44 ~nr 'LI..

~

ILILNIIIILIIIL meyLLLL 21Q . LI.-

~

CStfHCAT% Of ~ANCE

.4. ~

V We cenlfy aac d>> aaceenonce made ln thla tepon ate cottecc endtt>>c thle pump, ot.valve. confom>>

aIIII "-

Oe tulae af Addenda Ya m, N CNINcalt NQQattt Out ANN Cad&ere of Authokcedon No.

Tricentrlc Divisicn .

LI3hl io uee Oe

'S

~ IIII'4PIIIL 6/8l/%

oe .

q ~

~;, '...,,

~...

DeelOn infonnedon on Sbeee anelyele tepott (Oeee le ec 1

' ~,

onlyl on Oe ec CSRTPCNNN 'INON Deeiya epecl5cedone ~led by (fl Scteee cenNed by il),

')1 spnelee not teeuited. Lice nano eely.

- ~ 'I-.v.' <<1 .;,'2;,'-4'IgfPICA75 Of ~ Ngf!CT)OH I Oe undeteiined; hoNnI e veNd commlealon ieeued by oe Natonal Ioetd of loller end Aeee22te Weeal b~dore nd employed by *

~ nd Oe eceee or ftevinco ef of hove Inepecced Oe pump. or vere, deecHbod ln Ole Deke hapotc m

)0~, end easooecloee bee otmy IQnewledoe end beNet.oe N cenMlcea Holdaheecon eauceed Ole pump, er veiv>>. ln accordance vQOh Oe ASMI Code. Secdon N.

~ y eiininy Ne ce&HceiII nQher oe Inepeceor not Ne employer mehee eny>>ettency eaptc>>eed et hapa4 eencendni

',V mav>>r Ier ~

0N equiptnenI deecrlbed ln Ne Dace hepotc. twthonnote. neioet Oe Inepeccot nor Ne etnployer eNI be Ielle In eny or ptope& darned ot e loca of eny ~ etielne Aotn ot conneclei ah% ole @operon.

ss-c

~I>>an

'onwnleeione (traced ee sea, ~ aae Nal gL ~

PSL-1, NIS-2 TRACKING NO. S L-2 56 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL

1. Owner Florida Power & Light Co. Date: 12/27/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: C95934-90011 6501 South Hwy. A I A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8218
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012801-03 6501 South Hwy. A I A WCD ¹: 0189 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification VALVEV-21189 Expiration Date N/A (Mark Number)

(c) Code Class:

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

VALVE- 4" SERIAL ¹ SA 516 GR.70 HENRY PRATT D0066-3-2 N/A N/A 1977 REPLACED NO VALVE- 4" SERIAL ¹ UTC 377172 SA 516 GR.70 HENRY PRATT DD343-1-2 N/A RIR 26612 1995 REPLACEMENT NO NUT,HH-SA194 ALLIED, NUT HEAT ¹ UTC 375497 5/8"-11UNC2B AND BOLT L63812 N/A RIR 25731 1995 REPLACEMENT BOLTNA193 ALLIED, NUT HEAT ¹ UTC 372557 5/8"-1 1UNC2A AND BOLT 88147-GP N/A RIR 1 J-0247 1994 REPLACEMENT

7. DESCRIPTION OF WORK: DURING INSPECTION, M/M SUPV. DETERMINED THAT THE VALVE NEEDED TO BE REPLACED.
8. Test Conducted: Hydrostatic [ ] Pneumatic f] Nominal Operating Pressure (ISLT) [ X]

Other: VT1 [] VT2[X] VT3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HQURs

PSL-1, NIS-2 TRACKING NO. S L 8 - '6 FORNI NIS-2 (Back) Sheet 2 of

9. Remarks ISLT FOR THE FLANGED CONNECTIONS ON VALVEV-21189 WAS SATISFACTORILY PERFORMED.
10. Inspection Report Numbers: M95-313 APPLICABLE MANUFACTURER's DATAREPDRTB To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization N/A Signed Date / ~7, 19 Own s or Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date ~ 27 19~a

PSL-I, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/1/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power & Light Co. PWO¹: 3609 6501 South Hwy. A1A WO ¹: 95001904 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No. N/A (b) Component PORV V1475 Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 1 a) Applicable Construction Code and Addenda: ASME Sect III 1977 Ed / S 79 Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement PorN) onnei arrett ep ace Gr F316 onnei rosy a e ena o 9 4 ep acement K7204-324002 Gr F316

7. Description of Work: Replace bonnet due to loose bonnet guide.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

VT2 VT3 Test Temp. IF Other: VT1 psig

PSL-2, NIS-2 TRACKING NO. SL-2 FORII NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Autho zation No.: N/A Signed ner r neCs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions lnspectoCs Signature National Board, State, Providence and Endorsements

~

>>' >> ~ 'r, >>>>S 'I.'>>>>'>>>>>>'.I >>>>>>>>>>>>'>> '. I ", >>;c ' ' ~ >>', .

  • Ili CL

( L re&

~ I I ~

J

~ ~ >>

~>> ~

~, ~ ~ ~ $0 ~ 1

>> ~ >> ~ II ~:I ~

>> I ~ I I II II I I

>> ~ ~ ~

' ~ ~ ~ >>

~

~

~ ~ ~ ~ ~ ~ ~

~ ' ~ I ~ ~ >>

~

~

' ~ ~ ~ ~

~ ~

~ ~ ~

~ ~

~ >> ~

1 ~ ~

~ >> i

~,

~ ~ ~ ~

1 ~ ~

I ~

' ~ ~ ~ >> ~ i ~

~ ~ ~

~ ~

~ ~ ~ >>

~ ~ ~ ~ a ~ >>

~ ~

~ ~ ~ >> ~ ~ ~ \ ~ ~ ~ >> ~ ~ >>

~ ~ 1 ~ ~ >>

~ ' ~

~ ~ ~ >>

~ ~

~ ~ >>

~ ~ I

~ ~ ~l P I

~ ' ~ ~ I IW 'j,i a

~ I ~ ~ ~ I ~ ~ I

~ ~ ~ I ' ~

'c>i~j

~ ~ ~ ~ /g I I I

~ ~ I ~ ' I js i fr.~

I ~ ~

~ I ~ ~ I ~ ~ ~

~ ~

L ~

~ ~

' ~ ~ ~

~

~ I I ~ '

9 ~-":iW 7 "~5fipM9~vRQXLa ~JK8Ka.".F&~~~d,'W~~4~W" lj J J

g "i,

"\1

~ '

~ gg

~

~ ~ ~

~

Iy

~ ~

I

~

~

~ ~

~

I Lt[ ~ '

~

~

~

g'

~

I I

~

~ ~

I I

~

~

~

~

~ ~ ~

~

I

~

~ I

~ I I

LI I ~ ~

I I I ~

,gl jL/

~ I~

I I ~ ~ ' ~ ~ ~ I ~ ~

' ~ I ~ ~

i'

~ ~ I I I ~ ~ ~ ~

~ ~ ~ ~ ~ ~, '

~ ~

~ ~ ~ ~ ~ 1

'I I ~ ~ I ~

~ ~ ~ ~ ~

' ~ . I  ; ~ I ' I 1 ~

.?~I '

~

I ~ ~ ~ ~ ~ I ' ' ~ ~ ~ I ~ ~ ~

8 I

.J~ .g gs "g

~, ~

L:,',

PSL-1, NIS-2 TRACKING NO. SL-2 ~058 F g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/14/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By. Florida Power & Light Co. PWO ¹: 4972 6501 South Hwy. A1A WO ¹: 95027851 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A HCV-3635 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

Seal Weld NA Ht No NA P8To P8 NA Replacement (SI-2000) DT 6289 ER 316

7. Description of Work: 'Remove seal weld for valve inspection and reweld following examination.
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 ~prig TeetTemp. ~'P Nominal Operating Pressure (ISLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 OSS FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed WPI .U I/-lSl Date ~&II i 19~7 Own r r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this OwneVS Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

M .k~

Inspectors Signature Commissions NB7719 FL Com ¹60 National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. S L 8- 59 FORM NIS-2 OiVFAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/18/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. AIA PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8210
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012782-01 6501 South Hwy. AIA WCD ¹: 0195 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification EXPANSION JOINT Expiration Date N/A (Mark Number) SJ-21-4A (c) Code Class: 3
5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N) 24" EXPANSION PATHWAY ¹ HT AMNT JOINTSA182 F316 BELLOWS ¹ PT B-14392 N/A REPLACED NO 24" EXPANSION HT¹ 610VNE UTC 384322 JOINTSA182 F316 ABB/CE PT¹ B-1-7832 RIR 3H-3361 1993 Replacement NO BOLT, SA 193 GR.B7 ALLIED NUT HEAT ¹ UTC 379706 1 1/4"- 8UN2A AND BOLT CO. 90755 NIA RIR 2H-1680 1993 Replacement NO NUT, HEAVY HEX SA 194 GR. 2H ALLIEDNUT HEAT ¹ RIR 21-1002 1994/

1 1/44UN2B AND BOLT CO. E97817/151593 N/A RIR 24742 1995 Replacement NO

7. DESCRIPTION OF WORK: EXPANSION JOINT WAS REPIACED BECAUSE OF PITTING AND CORROSION.

BOLTING, BECAUSE OF NORMALWEAR AND.TEAR.

8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [X ]

Other. VT1 [] VT2[X] VT 3 [] sYsTEM PSIG Test Temp. BYBTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 59 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN ISLT WAS SUCCESSFULLY PERFORMED ON THE FLANGED CONNECTIONS AND WITNESSED BY A CERTIFIED Q.C. INSPECTOR
10. Inspection Report Numbers: M95-302 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair (X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date Dt'-1'- ~

19 ~$

Owners or ne esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

8d Commissions National Board, State, Providence and Endorsements Inspectors Signature Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/21/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant:,, St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By. Florida Power & Light Co. PWO¹: 4518 6501 South Hwy. A1A WO ¹: 95018944 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V3550 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 tern a) Applicable Construction Code and Addenda: ASME SEGT III 1974 Eomow SuM 75 Aoo Code Case: None (b) Applicable Edition of Section Xl Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification ol Stamped Material Replacement (Yor N) bise em arge o cp acc Assembly TP 347 isc arget o 0 ep accment Assembly 0000352219 TP 347

7. DescriptionofWork: Replacedisc/stemassembly Note: Seal weld replaced Ref WO95030191 / NIS-2 SL-2-8-060
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp.

PSL-2, NIS-2 TRACKING NO. SL FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector
10. Inspection Report Numbers: 1VlI41 9g ZGD f APPLICABLE MANOFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair +Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 4& Zp )t.ftlvi gv~ hSL Date ititttt eID- 19 W nsr o nei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Insp'tor's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 061 i g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/24/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA
3. Work Performed By'Florida Power & Light Co. PWO¹: 5226 6501 South Hivy. A1A WO ¹: 95030191 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V3550 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 Applicable Construction Code and Addenda: ASME SECTION III; 1980 EDITION Code Case: None

)

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification of Stamped OI'aterial Replacement (Y or N)

SEAL WELD FPL WELD TRAV¹ NA Replacement FW-2003 954375

7. Description of Work SEAL WELD 8 FILLET WELD
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 ~pstg TestTemp. ~'F Nominal Operating Pressure (ISLT) X

PSL-2, NtS-2TRACKtNG NO. SL-2 ~061 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector
10. Inspection Report Numbers: QCR: 2009 APPUCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Cu, 9Z Date ttAe< 2'I 19 er or ei's Designee, Title 95'ERTIFICATE OF INSERVICE INSPECTION e

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹6 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 inspector's Signature National Board, State, Providence and Endorsemants Date 19 JCC

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/20/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By Florida Power & Light Co. PWO¹: 5229 6501 South Hwy. A1A WO ¹: 95030271 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V3495 Expiration Date N/A Identification:

(Mark Number)

(c) Code Class: 2 NA Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and.Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Y or N) ea e ea o ep acemen DT 6289 95-'33+% (P8 to P8)

7. Description of Work: Remove and replace seal weld to facilitate valve work.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other. VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: MM95-1892 APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed sp f4sn sUpa2ulsa2. ~<~ Dale u~. 0> 19 ~D Owne o Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date j- ( -,19~~"

PSL-2, NIS-2 TRACKING NO. S L 8- 63 FORM NIS-2 OiVNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 01/18/96 P. O. Box 529100 Sheet: 3 of 3 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957
3. Work Performed By: Florida Power & Light Co., 6501 SA1A Hwy., Jensen Bch., FL 34957
4. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASMF Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

ELBOW, 4" 90 DEG., SA 234 NIA NIA N/A N/A N/A Replaced ELBOW, 4" DUBOSE NATL HEAT ¹ UTC 381319 90 DEG., SA 234 ENERGY N87038 N/A RIR 30129 1995 Replacement NO ELBOW, 4" 45 DEG. SA 234

~ N/A N/A NIA N/A Replaced NO ELBOW, 4" DUBOSE NA'PL HEAT ¹ UTC 381320 45 DEG. SA 234

~ ENERGY N75134 N/A RIR 30129 199s Replacement BOLT- SA193 ALLIEDNUT HEAT ¹ UTC 347675 5/8"-11UNC2A AND BOLT 88147-GP N/A RIR 1J-1421 1994 Replacement NO BOLT- SA193 ALLIEDNUT HEAT ¹ UTC 374492 5/8"-11UNC2A AND BOLT 8078593 N/A RIR 24742 1995 Replacement NO NUT-SA 194 ALLIEDNUT HEAT ¹ UTC 375497 5/8"-11UNC2B AND BOLT L63812 NIA RIR 25731 199s Replacement NO BOLT- SA193 ALLIED NUT HEAT ¹ UTC 373936 1 1/4"-8UNC2A AND BOLT 8894177 N/A RIR 24401 199s Replacement NO NUT-SA 194 ALLIEDNUT HEAT ¹ UTC 374489 1 1/4"-8UN2B AND BOLT 151593 N/A RIR 24742 1995 Replacement NO

PSL-1, NIS-2TRACKING NO. S L-2 63 FORM NIS-2 OIVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 01/18/96 P. O. Box 529100 Sheet: I of 3 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8218
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012801-01 6501 South Hwy. AIA WCD ¹: 0187 Jensen Beach, FL 34957
4. (a) Identification of System INTAKECOOLING WATER Type Code Symbol Stamp N/A (b) Component Identification LINE I-364iV-16 Expiration Date N/A (Mark Number) LINE I-30-CiV-2l (c) Code Class: 3
5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

FLANGE, SA 105 4", WELD NECK N/A N/A NIA N/A NIA Replaced NO FLANGE, SA 105 TIOGA PIPE HEAT ¹ UTC 374412 4", WELD NECK SUPPLY CO. 8860283 NIA RIR 24917 1995 REPLACEMENT NO FLANGE, SA 105 4", SLIP ON N/A N/A NIA N/A NIA Replaced NO FLANGE, SA 105 TIOGA PIPE HEAT ¹ UTC 378524 4", SLIP ON SUPPLY CO. 8861721 NIA RIR 27818 1995 REPLACEMENT NO PIPE, 4" TIOGA PIPE HEAT ¹ UTC 382058 SA106 SUPPLY CO. N87139 N/A RIR2K-0032 1994 REPLACEMENT NO

7. DESCRIPTION OF WORK: PUP" PIECE ADDED TO EASE FIT UP OF FLANGE. BOLTING AND FLANGES, WHICH WERE WORN, DUE TO NORMALWEAR AND TEAR WERE REPLACED PER FPL DIRECTION.
8. Test Conducted: Hydrostatic [X] Pneumatic [] Nominal Operating Pressure (ISLT) [ X]

Other. VT1 [] VT2[X] VT3[] ISLTaYS. PSIG Test Temp. sYsTEM F HOLDTIME HYDRO-10MIN. O100PSIG Hold Time IsLT-4 HRs

PSL-1, NIS-2 TRACKING NO. S L 8 - 63 FORM NIS-2 (Back) Sheet 2 of

9. Remarks IsLTwAs sATlsFAGTQRILY PERFQRMED FoR THE FLANGED coNNEGTIQNs.

HUDROSTATIC TEST WAS SATISFACTORILY PERFORMED ON THE WELDED JOINTS.

10. Inspection Report Numbers: M95-198 AND M95-309 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X) Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorizati No N/A Signed Date wners or Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹13 starting on 12/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions ~r>~l Inspectors Signature National Board, State, Providence and Endorsements Date <9~4

PSL-2, NIS-2TRACKING NO. S L-2 65 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/27/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. AIA PCM¹: N/A Jensen Beach, FL 34957 NPWO ¹: 7709
3. Work Performed By: Florida Power & Light Co. WO ¹: 95010521-1 A 6501 South Hwy. A1A WCD ¹: N/A Jensen Beach, FL 34957
4. (a) Identification of System STEAM GENERATOR Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 2B COLDLEG HANDHOLE Expiration Date N/A (Mark Number)

(c) Code Class: I

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

HELI-COIL HEAT ¹ UTC 385001 SA 479 ABB/CE 51892 N/A RIR 3AF-2278 1992 REPAIRED

7. Description Of Work: ENGINEERING PROCEEDURE 'EP-9448-CSE91-2131 ADDRESSES THE REPAIR OF STUD HOLES WITH THE USE OF HELICOIL INSERTS.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [X ]

Other: VT1 [] VT2[X] VT 3 [] sYsTEM PSIG Test Temp. sYBTEM F Hold Time 4 HDURs

PSL-1, NIS-2TRACKING NO. S L-2 65 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN IsLT wAs sUGGEssFULLY PERFQRMED AND wlTNEssED BY A CERTIFIED VT-2 Q.C. INSPECTOR
10. Inspection Report Numbers: M95495 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [X ) Repair [ ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorizatio No N/A Signed Date Brs or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the OwneCs Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind adsing from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date 19~(

PSL-1, NIS-2 TRACKING NO. SL-2 Fp FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. 2389 'WO¹:

6501 South Hwy. A1A WO ¹: 95001683-01 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A

4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A HCV-3657 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME Sect III 74 Ed./Sum 76Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement PorN) a er isc ames urry ep ace Shaft Assembly Corp. Gf CF8M a er isc ames uriy ena o 351 ep acement Shaft Assembly Corp. RKG-1 Gr CF8M ange tu s aw A 19 ep ace 1 X8unc2A Gr 87 ange u s ova eat o S 93 ep acement 1 X8unc2A 8090323 Gr 87

7. Description of Work: Replaced disc assembly and flange bolting - >~+ P~PlcLrs-'d

+g ~en+ lm~gc

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other. VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORII NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inseivice leakage test was performed and witnessed by a VT-2 certiTied inspector.
10. Inspection Report Numbers: MM95-1893 APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed M ner

~a. P~ Gum- t~f Ownei's Designee, Title CaIe IOgu S~C Ig~T CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

/ Commissions inspector's Signat'e National Board, State, Providence and Endorsements Date 19 WJ

~ 0 ~

~ I ~ ~ ~ ~ ~ ~

~ 0 ~ ~ ~ ~ ~ ~ l ~ \

~ ~ .

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ' ~

~ ~ ~ ~ ~ \ ~

P ~ ~

I ~ ~ I

~ ~ ~ ~ ~ I ~ I ~ ~ I

~ ~

~ ~ II ~ ~

~ ~ P ~ ~

~ ~ ~ ~ ~ II ~

~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~ ~

~ ~

FORM N 2(back)

CERTIFICATE OF DESIGN NY Design specifications certified by T.L. Kettles P. E. state Rag. no.

N/A

'/A N/A P. F state Reg. no.

Destgn report certltied by CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made In this report are correct and that this phase) conform to the rules ot construction ot the ASME Code,Section III.

October 27, 1993 ASME Certificate of Authorization no. Expires

~ F2. Neles-Jamesbury, Inc.

Oate Name

~ cervlaeco saasen Signed ianhariaed yreserasim)

I CERTIFICATE OF SHOP INSPECTION I, the underslpned, holdinp a valid commission Issued by the National Board ot Boiler and Pressure Vessel Inspectors and the state or pro.

nd employed by protection Inca oiMassachuset ts Mutua 1 of oorj MA have Inspected these Items described In this data report on best of my knowledge and belief, lhe Certificate Holder has fabricated these parts or appurt Section tli. Each part listed has been authorized for stamping on!he dale shown above.

By ~ Ipnlng this certilicate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment scribed In this data report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal Injury or rty damage or loss ol any tdnd arlslnp from or co with this Inspection. pactory Mutual Systems Gate Commissions

~hOHCKt IhiOOCIN) y4ark ed. ImL endorsemontn slate w pew. end no)

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/28/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 158-295M 3, Work Performed By. Florida Power & Light Co. IWO¹: 3613 6501 South Hwy. A1A WO ¹: 95002158 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Containment Spray Type Code Symbol Stamp N/A FCV-07-1A Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME Section III 74 Edition / No Add. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped OI'eplacement Material (Y or N) ae a ves 4 ep ace 300 Ib/8 Gr 316 ate ooper Sea o 240 9 4 ep acement 300 Ib/8 Industries K272620 Gr 316

7. Description of Work: Replaced gate due to erosion
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2 t.

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: hii ~ q g Q 7g APPLICABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Auth rization No.: N/A Signed r r Owner's Designee, Title pv - IS Date ~~ 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components descdbed in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2TRACKING NO. S L-2 68 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FPL

1. Owner Florida Power & Light Co. Date: 12/27/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. f/: N/A 6501 South Hwy. AIA PCM¹: N/A Jensen Beach, FL 34957 NPWO f/: 7709
3. Work Performed By: Florida Power & Light Co. WO jj: 95010521-1A & 01 6501 South Hwy. A1A WCD f/: N/A Jensen Beach, FL 34957
4. (a) Identification of System STEAM GENERATOR Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 28 COLDLEG HANDHOLE BOLTING Expiration Date N/A (Mark Number)

(c) Code Class: 1

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

STUD - SA193 HEAT ¹ UTC 314658 1"-8UNC2A X 6" ABB/CE 85689 N/A RIR 1H-1524 1992 Replacement NO STUD - SA1 93 COMBUSTION HEAT ¹ UTC 314658 1"-8UNC2A X 6" ENGINEERING 85689 N/A RIR 1H-2360 1983 Replacement NO NUT- SA193 COMBUSTION HEAT¹ UTC 314662 1"-8UNC ENGINEERING 215272 N/A RIR 1H-2360 1983 Replacement NO

7. Description Of Work: BOLTING MATERIALREPLACED BECAUSE OF ONE BROKEN STUD AND NORMALWEAR AND TEAR ON THREADS OF ANOTHER
8. Test Conducted: Hydrostatic [ ] Pneumatic f] Nominal Operating Pressure (ISLT) [X ]

Other: VT1 [] VT2[X] VT 3 [] SYSTEM PSIG Test Temp. sysTEM F Hold Time 4 HQURs

PSL-1, NIS-2 TRACKING NO. S L 8 - 68 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
10. Inspection Report Numbers: M95<95 APPLICABLE MANUFACTURER'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorizatio No N/A Signed Date Z ~, 19~&

ers or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle f/8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. S L 8 - 69 FORM NIS-2 OiVNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/27/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM¹: N/A Jensen Beach, FL 34957 NPWO ¹: 7709
3. Work Performed By: Florida Power & Light Co. WO ¹: 95010526-01 6501 South Hwy. A1A WCD ¹: N/A Jensen Beach, FL 34957
4. (a) Identification of System STEAM GENERATOR Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification 2A HOTLEG HANDHOLE BOLTING Expiration Date N/A (Mark Number)

(c) Code Class: 1

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

NUT- SA193 COMBUSTION HEAT ¹ UTC 314662 1"-8UNC ENGINEERING 215272 N/A RIR 1H-2360 1983 Replacement STUD - SA193 COMBUSTION HEAT ¹ UTC 314658 1"-8UNC2A X 6" ENGINEERING 85689 N/A RIR 1H-2360 1983 Replacement NO

7. Description Of Work: BOLTING MATERIALREPLACED BECAUSE OF WORN THREADS DUE TO NORMALWEAR AND TEAR.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [X ]

Other: VT1 [] VT2[X] VT 3 [] sYsTEM PSIG Test Temp. sYsTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 69 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
10. Inspection Report Numbers: M95-497 APPLICABLE MANUFACTVREIrsDATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Author tion No N/A Signed Owners or Owners Designee, Title Date /Z >7, 19 9'5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cyde ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-2, NtS-2TRACKtNG NO. SL-2 ~070 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F ~

As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 1/22/96 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucio Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JcnsenBcach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power & Light Co. PWO¹: 4894 6501 South Hwy. A1A WO ¹: 95025593 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdcnQication of System: Safety Injection Type Code Symbol Stamp N/A V3217 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 1 None a) Applicable Construction Code and Addenda: ASME SEC. III;1974 ED.; S74 ADDENDA Code Case:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

DISC WESTINGHOUSE S/N-2025 NA SA182 GR. F316 NA Replaced DISC WESTINGHOUSE S/N 4499 NA SA182 GR. F316 NA Replacement BONNET NUTS ALLIED ¹ HT 500260 NA SA 453 GR 660 NA Replacement

7. Description of Work: REPLACE DISC ASSEMBLY 8 BONNET NUTS DUE TO WEAR.
8. Tests Conducted: Hydrostatic Other: VT1 X

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (tSLT)

~Psig TestTemP. ~'P X

PSL-2, NIS-2 TRACKING NO. SL-2C- ~070 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT CERTIFIED INSPECTOR.

CUING.)

10. Inspection Report Numbers: MM95-1692 & 1694 (VT 1)

I7I7AR4 - IS.S APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Own

~ PL/i.fat~

Owner's Designee, Title gVPV, tSI Date Atl otk 19 l4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 inspector's Signature National Board, State, Providence and Endorsernents Date

PSL-1, NtS-2TRACKtNG NO. SL-2 ~871 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/14/95 P.O. Box 529100 Slleet; 1, of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: 5342 Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹: 5324 6501 South Hwy. A1A WO ¹: 95031268 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdenQicationofsystem: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V3225 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 1 None

) Applicable Construction Code and Addenda: ASME SEcr III 1980 Eomoii / W80 ADD Code Case:

(b) Applicablc Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

Weld Repair NA Ht No NA P8To P8 NA Repaired Bonnet CT6100 0434 SA 182 TR316

7. Description of Work: Weld repair bonnet pressure seal area.
8. Tests Conducted: Hydrostatic Other VT1

~ Pneumatic VT2 X VT3 ~psig Test Temp. ~'P Nominat Operating Pressure (tSLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 ~071 FORM NIS-2 (Back) 'heet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbeis: g$ Wg'.j 7 g8'S APPLICABLE MANUFACTURES OATA REPORTS To BE ATTACHED CertiTicate of Compliance We certify that the statements made in the report are correct and this X Repair Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed OwiIer or er's Designee, Title S~PV - LS) Date~llN t., 19 0L2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com 440-~ p tnspectol's Signature National Board, State, Providence and Endorsements

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/20/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St;-Lucie Nuclear Plant 6501 South Hwy. AIA P.o.f/: NA

'ensen Beach, FL 34957 PCM/f: NA

3. Work Performed By: Florida Power & Light Co. PWO/f: 1118 6501 South Hwy. A IA WO f/: 94015104 Jensen Beach, FL 34957 CWO k NA Process Sheet: N/A
4. (a) Identification of System: Feedwater Type Code Symbol Stamp N/A Authorization No. N/A (b) Component MV09-11 Expiration Date N/A Identification:

(Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEcT III 1974 EomoN No AooEttoA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement (Yor N) ave ug ep ace 4" /600 Ib TP 316 ave ug nc or 0 4 9 9 0 ep acement 4" /600 Ib Darling 0000379151 TP 316

7. Description of Work: Replaced plug due to damaged seating surface
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

VT2 VT3 Test Temp. 'F Other: VT1 psig

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: 'r'<%giO Z 4O~

APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization t No.: N/A Signed KP PmmiSOPV ls'I Date ILDV QD 19 RE ne Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Ownei's Report during operating cycle & starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements

PSL-1, NtS-2 TRACKING NO. SL-2 ~374

~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/12/95 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant: St. Lucic Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3640 6501 South Hwy. A1A Wo ¹. 94025096 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A 4., (a) Identification of System: Feedwater Type Code Symbol Stamp N/A V09157 Authorization No. N/A (b) Component Identification: 4'Aux. Fd Wtr. Expiration Date N/A (Mark Number) CHECK VLV

'(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC. III; CL 2 1974 ED.-'76 ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Yor N)

DISC (FOR CONTROL S/N: M336830 NA SA 216; GR. NA Replacement VALVE) 4'HECK COMPONENTS WCB 3/4'-10 UNC 2A ALLIEDNUT & BOL HT¹ 88147 NA SA 193; GR 87 NA Replacement ALLTHREAD 3/4 -10 UNC 28 ALLIEDNUT & BOL HT¹E04277NA NA SA 194; GR 2H NA Replacement HEAVY HEX NUTS

7. Description of Work: REPLACE DISC DUE TO WEAR.

REPLACE BOLTING DUE TO CORROSION

3. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 ~psig TestTemp. ~'P Nominal Operating Pressure (tSLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 ~074 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: ivy tv' 4 - V lg APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed SR upv. IS( DaIe~EC. I'8 19~1 r or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. SL-2 075 F g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rcquircd by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power k Light Co. Date: 1/22/96 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power k Light Co. PWO¹: 3640 6501 South Hwy. A1A WO ¹: 95003428 JensenBeach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3414 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC. III; 1971 ED.; S74 ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement (Yor N)

DISC ASSEMBLY TARGET ROCK NA NA SA479 TQ47/348 1976 Replaced DISC ASSEMBLY TARGET ROCK NA SA479 T-347/348 NA Replacement

7. Description of Work: REPLACE DISC DUE TO WEAR
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VTS Nominat Operating Pressure (ISLT)

~psig TestTemp. ~'F X

PSL-2, NIS-2 TRACKING NO. SL-2 ~070 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: MM95-2351 APPUCABLE MANUFAC1URES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed L +~ PL& ZDI ~ Date ~aeA ~2, 19~4 0 or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

ED Commissions NB7719 FL Com¹60 inspector's Signature National Board, State, Providence and Endorsements Date 94, 19~

PSL-2, NIS-2 TRACKING NO. S L 8- 76 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS FPL As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/19/95 P. O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8220
3. Work Performed By: Florida Power & Light Co. WO ¹: 95013790-1A 6501 South Hwy. A1A WCD ¹: N/A Jensen Beach, FL 34957
4. (a) Identification of System SAFETY INJECTION Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification SUPPORT SI4201-7760 Expiration Date N/A (Mark Number) SNUBBER 2467 (c) Code Class: 1
5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

'BRACKET, PT¹ SERIAL ¹ BEA22-11A-10 NAVCO 5623-30 NIA UTC 381536 1983 REPACEMENT

7. DESCRIPTION OF WORK: AS FOUND CONDITION DID NOT MATCH DWG. INSTALL NEW PART PER DWG. & AS BUILDAS REQUIRED.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) f ]

Other. VT1 [] VT2[] VT3 [X] PSIG Test Temp. F Hold Time

PSL-1, NIS-2TRACKING NO. S L-2 76 FORM NIS-2 (Back) Sheet 2 of

9. Remarks A FINALVISUALEXAM WAS PERFORMED BY A VT-3 CERTIFIED INSPECTOR .
10. Inspection Report Numbers: 95-PSL-2067 APPLICABLE MANUFACTURER'S DATAREPORTS TO BE ATTACHE0 Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [X ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Date )Elf~I, 19 Owners or Own s Desi ee, Title OF INSERVICE INSPECTION 'ERTIFICATE I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle f/8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signa ure National Board, State, Providence and Endorsements Date

PSL.2, NIS-2 TRACKING NO SL-2.8. ~077 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 3/8/96 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucic Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹: 5377 6501 South Hwy. A1A WO ¹: 95031723 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No, N/A (b) Component V1234 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 1 a) Applicable Construction Code and Addenda: ASME SECTION III; 71'D.-W

'73 ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year 'eplaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement (Yor N)

STUDS ALLIED 52825-DF SA 193, Bj NA Replacement 7/8'-9 UN C 2A NUTS ALLIED NU312565 NA SA 194 GR 2H NA Replacement 7/8'9 UNC 2B

7. Description of Work: REPLACE BLIND FLANGE BOLTING DOWNSTREAM OF 2 DRAIN VALVE DUE TO HEAVY CORROSION .
8. Tests Conducted: Hydrostatic Other; VTI X

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLTI

~[Pstg Test Temp. ~'F X

PSL-2, NIS-2 TRACKING NO. SL ~077 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION OF THE NEW BOLTING (VT 1) AND A'N FOR LEAKAGE (VT 2) WAS PERFORMED. 'NSPECTIONN
10. Inspection Report Numbers: MM95-1 771 &

MM95-2484 APPUCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed As er or

<<a p~ S~e~

ai's Designee, Title IS i CaIe > I 27 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Co.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹329 Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2TI2ACKING NO. SL-2 ~078 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/8/95 P.O. Box 529100 Sheet:

Miami, FL 33152 Unit: 2

2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 91-8220 6501 South Hwy. A1A WO ¹: VARIOUS Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System SNUBBERS Type Code Symbol Stamp N/A 2-039,2-046 Authorization No. N/A (b) Component Identification: 2-066,2-067 Expiration Date N/A (Mark Number) 2 p84 2 p88 (c) Code Class: ALL 2 125, 2 15p 2-156 a) Applicable Construction Code and Addenda: ASME SEC. III; 1977 ED THRU '79 ADD.

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification of Stamped Material Replacement (Yor N)

PSA 1/4 SNUBBER: PACIFIC S/N 38499 (OLD) NA WO¹ NA Replacement 2439 SCIENTIFIC S/N 38503 (NEW) 9501375841 PSA 1/4 SNUBBER: PACIFIC S/N 11832 (OLD) NA WO¹ NA Replacement 2446 SCIENTIFIC S/N 38510(NEW) 9501378541 PSA 10 SNUBBER: PACIFIC S/N 17848 (OLD) NA WO¹ NA Replacement 2-066 SCIENTIFIC S/N 16610 (NEW) 9501378741 PSA 10 SNUBBER: PAC. SCIENTIC s/N 12848 IQLo) WO¹ 950137904 RepIacement s/N 81256/32 INEw) 2467 LISEGA 3062 RF1 NA'A PSA 3 SNUBBER PACIFIC S/N 29504 (OLD) WO¹ RepIacement 2484 SCIENTIFIC S/N 24747 (NEW) 9501371541 PSA 1 SNUBBER PACIFIC S/N 7419 (OLD) WO¹ NA Replacement 2-088 SCIENTIFIC S/N 12289 (NEW) 9501378841

7. Description of Work: REPLACE SNUBBERS DUE TO TEST FAILURES. REFER TO INDIVIDUALWORK ORDERS FOR SPECIFIC DETAILS. s
8. Tests Conducted: Hydrostatic Other: VT1

~ VT2 Pneumatic VT3 X ~psig TestTemp. ~'F Nominal Operating Pressure (ISLT)

PSL-2, NIS-2 TRACKING NO. SL-2 ~078 FORM NIS-2 (Back) Sheet 2 of 3

9. Remarks: A POST INSTALLLTIONVT 3 WAS PERFORMED FOR ALL SNUBBERS.

INFORMATION RECORDED ON INDIVIDUALVT 3 INSPECTION REPORTS ON FILE.

10. Inspection Report Numbers: VARIOUS.

APPLiCABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Signed A Ow

'~

Certificate of Authorization No.: N/A

~Citii @Pt/- IXI r or Owner's Designee, Title Date ~IS'9~9 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 lnspectoi's Signat re National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 ~078 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI PL SUPPLEMENTAL SHEET

1. Owner: Florida Power & Light Co. Date: 12/8/95 P.O. Box 529100 Mami, FL 33152 Sheet: 3 of 3
2. Plant: St. Lucie Plant Unit ¹: 2 6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA
3. Work Performed By: k Florida Power Light Co. PCM ¹: NA 6501 South Hwy. A1A
6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced ASME Name of Name of Manufacturer Other Year Serial or Heat Board Repaired Code Component Manufacturer Identification Built No. No. or Stamped Replacement (Y or N)

PSA 1/4 SNUBBER PACIFIC S/N 37659 (OLD) NA WOO NA REPLACEMENT 2-125 SCIENTIFIC S/N 38489 (NEW) 9501376941 PSA 1 SNUBBER PACIFIC S/N 14880 (OLD) NA WOII NA REPLACEMENT 2-150 SCIENTIFIC S/N 26002 (NEW) 95013771 ZI A1 SNUBBER PACIFIC S/N 12790 (OLD) NA Wot/ NA REPLACEMENT 2-156 SCIENTIFIC S/N 26008 (NEW) 9501375941

PSL-1, NIS-2 TRACKING NO. SL-2 ~gyp

~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 1/2/96 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucic Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹:

6501 South Hwy. A1A WO ¹: 94025103 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A

4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A MV-08-19B Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC. III; 1980 ED. NO ADDENDA Code Case: None (b) Applicablc Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Y or N)

PLUG ASSEMBLY PACIFIC VALVE NA NA SA 182 GR F11 1980 Rep'laced 10' 12'LUG ASSEMBLY CONTROL S/N 360270 NA SA 182 GR F11 1992 Replacement 10 X12 COMPONENTS BONNET STUDS CONTROL ¹ HT 231 50B NA SA 193 GR B7 NA Replacement 1 1/4 N UN X 7 1/4 COMPONENTS BONNET NUT NOVA MACHINE ¹ HT 8099455 NA SA 194 GR 2H NA Replacement 1 1/4 -8 UN 2B

7. Description of Work: REPLACE PLUG ASSEMBLY DUE TO STEAM CUTTING. STUDS 8 NUTS REPLACED DUE TO CORROSION.
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT8 Nominal Operating Pressure(ISLTI

~pstg TestTemp. ~'P X

PSL-2, NIS-2 TRACKING NO. SL-2 ~079 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKGE WAS PERFORMED AND WITNESSED BY A VT 2 INSPECTOR.

I

10. Inspection Report Numbers: MM95 1777(VTI} KR& ( L 6~i )

APPLICAB(.E MANUFACTuRES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

i Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Ow r or Own Designee, Title Cate ~I ~, 19~4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition no addenda.

~

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

C'57 Commissions NB7719 FL Com ¹ 60 Inspecto Vs Signature National Board, State. Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/1/95 P.O. Box 529100 Sheet: I of 3 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P,O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3572 6501 South Hwy. A1A WO ¹: 95001867 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdentificationofSystem: ComponentCooling Water Type Code Symbol Stamp N/A Authorization No. N/A (b) Component SS-21-1B Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 3 ASME Sect III 1989 Ed/No Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Y or N) tu over um ep ace 1"-Sunc x 6' Industries Gr B7 Cover ova eat o 93 Rep acement 1 -Sunc x 6 Machine 8090323 Gr B7 ut Cover um 94 ep ace 1 -Sunc Industries Gr2H ut over he ut eat o 9 ep acement 1'-8unc Bolt 090309 Gr 2H fT'i%9%1 urn A 3 ep ace 3/4 x10uncx51/2 Industries Gr B7 ova eat o 93 ep acement 3/4 x 10unc x 5 1/2 Machine 8078372 Gr B7

7. Description of Work: Replaced strainer cover bolting and handhole bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 3

9. Remarks: A satisfactory Inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPLICABLE MANUFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner nei's Designee, Title UPV (s( Date~, 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ff8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions inspector's Signature National Board, State, Providence and Endorsements Date Z- %'

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F PL SUPPLEMENTAL SHEET

1. Owner: Florida Power & Light Co. Date: 12/1/95 P.O. Box 529100 Miami, FL 33152 Sheet: 3 of 3
2. Plant: St. Lucie Plant Unit ¹: 2 6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA
3. Work Performed By: Florida Power & Light Co. PCM ¹: NA 6501 South Hwy. A1A
6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced ASME Name of Name of Manufacturer Other Year Board Repaired Code Component Manufacturer Serial or Heat Identification Built No. No. or Stamped Replacement (Yor N) u an oe urn ep ace 3/4" x 10unc -2B Industries Gr2H u an oe ie u ea o ep acemen 3/4 x10unc-2B Bolt E04277 Gr 2H

PSL-1, NIS-2 TRACKING NO. SL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power' Light Co. Date: 11/30/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3640 6501 South Hwy. A1A WO ¹: 95002733 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdentificationofSystem: Component Cooling Water Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V1 4147 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 3 a) Applicable Construction Code and Addenda: ASME Sect III 1974/ No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code of No. No. Identification Stamped OI'eplacement Material (Y or N) ave ISS On ep ace 20 Gr WCB a e au onroe / 990 ep acement 20 894952%1 Gr WCB ange u 8 Saw ep ace 1 1/8-8un 2A Gr 87 ange tu lie eat o 3 ep acernent 1 1/8- Sun 2A 52825 Gr 87 ange ut s aw 1 1/8-8un 28 Gr 2H ange ut eat o ep acement 1 1/8 - Sun 28 152550 TR 053 Gr 87

7. Description of Work: Replaced valve due to seal damage and flange bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp.

PSL-2, NIS-2 TRACKING NO. SL FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: tliriigQ 5 "Q.S p f APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed c a2 PLeur Uoov Isi o,<< IVov Eo Ig~q ner o wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2TRACKING NO. SL-2N- 082

~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/14/95 P.O. Box 529100 Sheet: 1 of 2 Miam, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By Florida Power & Light Co. PWO ¹: 5205 6501 South Hwy. A1A WO ¹: 95029884 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Containment Purge Type Code Symbol Stamp N/A FCV-25-36 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 Applicable Construction Code and Addenda: ASME Sect III 1977 Ed/ No add. Code Case: None

)

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built, Repaired Code No. No. Identification or Stamped OI'aterial Replacement (Yor N)

Wafer Controlmatics NF NA ASME SA 516 Replaced

( Disc) Gr 70 Wafer Controtmatics Heat No NA ASME SA 516 Replacement

( Disc) 8383726 Gr 70

7. Description of Work: Replaced disc due to wear
8. Tests Conducted: Hydrostatic Other: VT1

~ VT2 Pneumatic VT3 Nominal Operating Pressure itgLT)

~psig TestTemp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 ~082 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY LOCAL LEAK RATE TEST WAS PERFORMED.
10. Inspection Report Numbers: OP 2-'130051 APPLICABLE MANUFACTURE'S OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed l A date ner or 0 M Ptsan 8>PII-eVs Designee, Title ISI Cate~IN 19 tI5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Piessure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorsements Date

0 PSL-1, NiS-2TRAOKtNG NO. SL-2C- ~083 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/14/95 P.O. Box 529100 Sheet: 1 of Miam, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹: 1089 6501 South Hwy. A1A WO ¹: 94025102 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Iden@ication of System: Main Steam Type Code Symbol Stamp N/A MV-08-19A Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SEC. III 1980 ED; NO ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped ol'aterial Replacement (Yor N)

PLUG ASSEMBLY PACIFIC VALVE NA NA SA 182 GR F-11 1980 Replaced PLUG ASSEMBLY CONTROL SN¹: 360270 SA 182 GR F11 1992 Replacement COMPONENTS 1 1/4 N UN - 2B ALLIEDNUT & BOL HT¹ E 97187 NA SA194; GR2H NA Replacement BOONET NUT 1 1/4 W UN 2A ALLIEDNUT & BOL HT¹ 62413 NA SA 193; GR B7 NA Replacement ALLTHREAD

7. Description of Work: REPLACE BOLTING AND PLUG DUE TO STEAM CUTI ING AND CORRODED BOLTING
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 ~psig TestTetep. ~'F Nominal Operating Pressure (ISLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 083 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: Ph)'h fC I."I )

APPUCABLE MANUFACTURE'S DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed rt/ S I Date ~tZ I t tt~5 vmer or eVs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the'examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 InspectoVS Signature National Board, State, Providence and Endorsements Date 19~>

FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENA/ACES>>

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Prodtrction Pg. 1of2

1. Manut>>nceed and cecal>>dby Contest Ca nfronerrft hc.2259t Atwicfd GnprdddAvabo Sarrgt h4aryarttd. CA 92688 hens>>nc address d osrcna>>e Hcsdcrl
2. Menufactcsed for FLORIDA POWER AIVDUGHT. RAT PIERCE. FLORIDA hsn>> cnd eddcsse cr Ccneseci
3. Location of hstattaaon ST. L(IDIEPLANT.(WIT2, FORT PIERCE. FLORIDA hens end address)
i. Type 82060I612XX'A 182-Pf f 70,000 PSI H/A 1992 (dnssne nca) hc>>l >>ace. na} (te>>se crenate ftttrr)
5. ItsME code, seclon ttL oansion 1: f980 NO N/A (sdtasc) (Cade Csee ca,)

tL Fabricated h accocclance sett consL spec. (oN. 2 only) N/A sw'e'en cvA Dan NIA ha)

T. ecnsstaca FDRMCD(JLATIs 1/ENTDRAG VALVE/N26689-I Cgf )1/C4C 6f11f 1- f PL(Ae WC850270 rL Nora fftctcr>>rs (st,) 2.8 Mh. deign tnictcness 0rL) N/A Ota 0 (ft S h) 1.4'angat owait (ft S h) 12.6'.

vtr>>napptcabte. Certtccate Holders'Data Re porta are attacned for each fhm of tnta report Habceal Part or Apca>>enate>> Natlond Swd HcL Serial Ncanber Board NcL in Nwnencat Order h Ncanencat Order 860270 BH 1 (2tL)

(2.) 8602708/H2 (27) p.) (2tL)

(4) (2(L)

(5) pg.)

(a) P1.)

(7) (32)

(fL) (33.)

(0) pi.)

(ftL) p5.)

(1 1.) (3tL)

{12.) pl.)

(1 3.) PfL)

(1 4.) Pg.)

(15.) (4tL)

(1 tL) (41.)

(1 7.) (42.)

(1 5.) (43.)

{1 0.) (aa)

(30.) (45.)

'3$ .) {atL)

(22) (47.)

(23.) (45)

(34) (40.)

(35) (50.)

10. Oeeign presscse Q5$ pa. Temp. 660 oeg. F Hydrcc astpreeaae N/A 'tacmp. oeg. F

~ftuPPlenarearannSOCCnht>>rC>>nefaCCS.Ckcaear>>e.CrdnaaCnte n>>r be ueed CCCCSted (1) Sae b ~ tftatl. (g) idrnn>>arC h lane aenda CSC tW OPS ftCPCCt b hcacded cn eedc d>>d gs ense d>>>> b sera>>csd>>nt tw rsscca>> ro d>>ccs b cascaded el tee tcp d ten fccnn.

Tria farm g05a) cner be cbtahed ecsn he Ceder OsPC ASLE 22 Lees Ortsa BcscsÃZL Fee>>eccl faf OWtr 2XXL Page z3

N-2 FORM N-2 plack Pg. 2 a~2 csrgycoh Hokeer's serial etoa. XC2S ehroctger SrN 1 8 2

~ eoeoehrcknoensedby K N. CHOW I E are R sag, carat I s- sue hVA sea. na N/A

~

tea oerd1 hd fly ~ made h tlk ~c oe ocnos and tip hta thesee co he asae et ocnerakakn ca he stage code. secckn s. Qklaan s.

AlVEF, 1854k lt I f 0~tr COWVROLCCWPCNIENTSJVC hddh e ~ oorsnbhm ~ by he etdknct sacro cd eeoeer oae prseoae vessel epeooore end tre dirae or pro@acre et CALIIcURtV14 beet ct my oacedcte oee basal tre ~

oae ~ crtoeedby HARVARDS7K4M BOILER hlSPECTJONAND NSUROVCZCCtMPANY Header has bbtcered trees pens or zgxs~ h eoooneoars ~ tre AslE coos jeodcn

~

g, crrkicn k Sean pen treed bee bem acrhorkad ear ecamphce cn tw dace etcwn <<xaa sy ekyrhp Ns oerreketa, natrer tw haoecror ncs tsc empioyer makes waarrcnry, etrrsaeeed h tria cats Aaocrk ycatromae, Moat tre hapecror nck nta ~ nploter anat ba tcbl ~ h any eoae cd any khd ananp fram or l'I I g race trk hapecckn.

~ or hoaec1 ocakarmhee Q.t +

ear~ perscnat ~ tra aatencnc darorbed or property reenacts or (Nrcl scL hoaadhct ecknwneae axe %de or prot aae na) tR ~-+~~'age 7 af ~~

PSL-2, NIS-2TRACKING NO. S L-2-8-, 84 FORM NIS-2 OiVIAVERS REPORT FOR REPAIRS OR REPLACEMENTS FPL As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/18/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8211
3. Work Performed By: Florida Power & Light Co. WO ¹: 95012902-01 6501 South Hwy. A1A WCD ¹: 0204 Jensen Beach, FL 34957
4. (a) Identification of System COMPONENT COOLING iVATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification LINE I-20-CIV-97-2 Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board identification Built Repaired or Stamped Material No. No. Replacement (Yor N)

PIPE - 20" SA 106 GR. B NIA NIA N/A N/A NIA REPLACED NO PIPE - 20" TIOGA PIPE HEAT ¹ UTC 371811 SA 106 GR. B SUPPLY L63840 N/A RIR 22764 1995 REPACEMENT NO

7. DESCRIPTION OF WORK: 12" SECTION OF 20" PIPE REPLACED BECAUSE OF PIPE WALL REDUCTION DUE TO CORROSION
8. Test Conducted: Hydrostatic [X ] Pneumatic [] Nominal Operating Pressure (ISLT) []

Other: VT1 [] VT2[X] VT3 [] 105 PSIG Test Temp. sYsTEM F Hold Time 10 MINUTEs

PSL-1, NIS-2 TRACKING NO. S L-2 84 FORIN'IS-2 (Back) Sheet 2 of

9. Remarks A HYDRosTATIc PREssURE TEsTwAs succEssFULLY PERFDRMED QN THE WELDED JOINTS AND WITNESSED BY A VT-2 CERTIFIED Q.C. INSPECTOR.
10. Inspection Report Numbers: M95-425 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance Wecertifythatthestatementsmadeinthereportarecorrectandthis [ ]Repair [ ]Replacement

[X ] Modification conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Date ~< 19 [5 Owners or OwneVS Bsigne itic CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certiTicate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

7 i) Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-I, NIS-2 TRACKING NO. SL-2 ~088 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 1/4/96 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucio Nuclear Plant 6501 South Hwy. AIA P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA
3. Work Performed By. Florida Popover & Light Co. PWO¹: 4808 6501 South Hwy. A1A WO ¹: 95023617 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdenSication of System Chemical 8 Volume Control Type Code Symbol Stamp N/A CHG PP 2A Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC. III; '3 ED., 'S. '4 ADD. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Yor N)

VALVECOVER NUT NOVA MACHINE HT¹ 2FCS76 NA SA 194; GR 6 NA Replacement

7. Description of Work: REPLACE VALVE COVER NUT WHICH WAS FOUND TO BE CRACKED.

(POSSIBLY OVER TORQUED)

8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure(ISLTI

~psig Test Temp. ~'F X

0 0

PSL-2, NIS-2 TRACKING NO. SL-2-8<<085 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: ~~ Ig -Z.4 l+

APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

, Type Code Symbol Stamp:

of Authorization No.: N/A N/A'ertificate go Signed EUr v. DateM 19 tt ner ei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this OwneVs Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this OwneVs Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, rio addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

.g In pectoi's Signature Commissions NB7719 FL Com ¹60 National Board, State, Providence and Endorsements Oate

PSL-2, NIS-2 TRACKING NO. S L 8 - 86 FORM NIS-2 OiVIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/27/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 i Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 7709
3. Work Performed By: Florida Power & Light Co. WO ¹: 95010526-01 6501 South Hwy. A1A WCD ¹: N/A Jensen Beach, FL 34957
4. (a) Identification of System STEAM GENERATOR Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification MANiVAY,SECONDARY SIDE Expiration Date N/A (Mark Number)

(c) Code Class: 3

5. (a) Applicable Construction Code and Addenda: ASME 1971 S 1973 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

STUD - SA540 COMBUSTION HEAT ¹ 1-1/2" X 9" ENGINEERING 82158 N/A UTC 388124 1983 Replacement NO

7. Description Of Work: BOLTING MATERIALREPlACED BECAUSE OF WORN THREADS DUE TO NORMALWEAR AND TEAR.
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) [X ]

Other: VT1 [] VT2[X] VT 3 [] sYsTEM PSIG Test Temp. sYBTEM F Hold Time 4 HQURs

PSL-1, NIS-2TRACKING NO. S L-2 86 FORM NIS-2 (Back) Sheet 2 of

9. Remarks AN ISLT WAS SUCCESSFULLY PERFORMED AND WITNESSED BY A CERTIFIED VT-2 Q.C. INSPECTOR
10. Inspection Report Numbers: M95497 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No Nl Signed Date /Z. Z T, 19 ~b Owners o Ownei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Ownei's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/13/95 P.O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3638 6501 South Hwy. A1A WO ¹: 95002817 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification: V08163 Expiration Date N/A (Mark Number)

(c) Code Class: 3 ASME Sect III 1974 Ed/S 76 Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components; Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped OI'eplacement Material (Yor N) a ve isc aciic ave ep ace 600 Ib /4' Gr WCB e isc aci ic a ve eat o 26 Rep acemen 600 Ib /4 26M3 Gr WCB
7. Description of Work: Replaced disc which was damaged during disassembly
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2

~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: N~ q cP APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair +Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Stgaeg Jl/(!Zl, I 5 RP V IS ( DateZEC (3, 19~

Owne or nei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 19S9 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

8. Inspector's Signature Commissions National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. AlA P.O ¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 8958 6501 South Hwy. A1A WO ¹: 94009167 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component HCV-3512 Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 2 ASME Sect III 74 Ed. / Sum 76 Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped OI'eplacement Material (Y or N) e ge ames urry ep ace (Disc) Corp. Gr CFSM e ge ames urry ena o 3 ep acement (Disc) Corp. NJV-2 Gr CFSM

7. Description of Work: Replaced disc due to leakage.

no root cause identified.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2-S-FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: )5 f6 Q Q -3, 5 QQ APPLICABLE MANDFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed ( k( sR Pieei'Snp"e - (S Date ~d 2-'f, 19 Lg ne r Ovine VS Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-2. NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/13/95 P.O. Box 529100 Sheet: I of 2 Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 3624 6501 South Hwy. A I A WO ¹: 94025119 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A Authorization No. N/A (b) Component ldentiTication: V3468 Expiration Date N/A (Mark Number)

(c) Code Class: 2

) APPlicable Construction Code and Addenda: ASME Sect lii 1989 Ed / No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Compo'nents:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer, Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Yor N) net u s aw 3 ep ace 5/8 -11unc2A Gr 87 n et tu s ova eat o 193 ep acement 5/8 -11unc 2A 9965663 Gr 87 n et uts aw S 194 NA Rep ace 5/8 -11unc 28 Gr2H n et uts ie ut 8~et eat o 194 Rep acement 5/8 -11unc 28 97365 Gr 2H

7. Description of Work: Replaced bolting due to corrosion
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

VT2 VT3 Test Temp. 'F Other: VT1 psig

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.

NNqQ n I Qg

10. Inspection Report Numbers:

APPLICABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A SIgned I A cd ~

Owner r Owners Designee, Title pcc ISc Once&~a'.c I, I gag CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions inspector's Signature National Board, State, Providence and Endorsements Date

PSL-I, NIS-2 TRACKING NO. SL-2 ~090

~ FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/25/95 P.O. Box 529100 Slicct; 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucio Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 179-295M
3. Work performed By. Florida Power & Light Co. PWO¹: 5488 6501 South Hwy. AIA WO ¹: 95032597 Jensen Beach, FL 34957 CWO ¹: Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A HCV-3512 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: NA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Rcplaccment Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped oi'eplacement Material (Yor N)

FLAT BAR FRY STEEL CO HEAT¹ SAR79 TP 316 NA Replaced 1/4 X1/2 A1 2060 FILLET WELD FPL WELD TRAV¹ NA NA 1995 NEW WELD 3583 95-3583

7. Description of Work: SECURE PIN TO THE VAVLE DISC BY WELDING TO PREVENT DISC FROM ROTATING AROUND STEM.
8. Tests Conducted: Hydrostatic Other. VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLTI

~psig Test Temp. ~'F X

PSL-2, NIS-2 TRACKING NO. SL-2 ~000 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A ~w+c4N 1~+~4~ ~ l~Q< ~

CA'Hgeg Itnz~cS/,

1

10. Inspection Report Numbers: IAN95 Q.9 ~

APPUCABLE MANUFACTURES DATA, REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this X Repair Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed 0 er or Pb >qg ei's Designee, Title IS< Date Po U ~, 19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 inspector's Signature National Board, State, Providence and Endorsements Date j

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by thc Provisions of thc ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/7/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By Florida Power & Light Co. PWO¹: 3638 6501 South Hwy. A1A WO ¹: 94025126 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V08130 Identification:

Expiration Date N/A (Mark Number)

(c) Code Class: 3

) Applicable Construction Code and Addenda: ASME Sect III 1974 Edition/S 75 Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989,Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped oi'aterial Replacement (Y or N)

ISC acI ic ep ace (4'heck ) Valves Gr WBC ISC on ro eat o 26 199 ep acement (4 Check) Components A0342 Gr WBC

7. Description of Work: Replaced disc assembly due to damage.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2Z-FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: +W IQ (3, W APPLiCABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorizati n No.: N/A Signed Ow or Own i'esignee, EL Title PbattP I/ l5 Date~, 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorscments Date

PSL-2. NtS-2TRACtONG NO. SL-2 ~892 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 1/2/96 P.O. Box 529100 Sheet:

Miami, FL 33152 Unit: 2

2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: na Jensen Beach, FL 34957 PCM¹: na
3. Work Performed By: 'lorida Power & Light Co. PWO¹: 2960 6501 South Hwy. A1A WO ¹: 950103040 Jensen Beach, FL 34957 CWO ¹: Process Sheet: N/A f
4. (a) IdenQication o System: Auxiliary Steam Type Code Symbol Stamp N/A AFW PP 2B Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 3

) Applicable Construction Code and Addenda: ASME SEC. III; 1974 ED., NO ADDENDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped OI'eplacement Material (Yor N)

CAPSCREWS INGERSOLL RAND ¹ HEAT 94521 NA SA 193; GR B7 NA Replacement

7. Description of Work: REPLACE BOLTING DUE TO THREAD DAMAGE,.
8. Tests Conducted: Hydrostatic Other: VT1

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (18LT)

~pstg TestTemp. ~'P X

PSL-2, NIS-2 TRACKING NO. SL-2 ~092 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: Ivt re Q g

APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed SU V IG Date 8 19 Q4 Ovm r Ovmer's Oestgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 inspector's Signature National Board, State, Providence and Endorsements Date 0 K 19 54

PSL-1, NIS-2 TRACKING NO. SL-2 rP FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/12/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 i Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By'. Florida Power & Light Co. PWO¹: 5075 6501 South Hwy. A1A WO ¹: 95028673 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Feedwater Type Code Symbol Stamp N/A MV 09 14 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 3 a) Applicable Construction Code and Addenda: ASME Sect lli 1989 Ed / No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped OI'aterial Replacement (Y or N) onnet uts aa icvave ep ace 5/8 x11unc2B GR7 onnet uts Ie ut ot eat no A 94 ep acement 5/8 x11unc2B L63812 GR7 onnet tu s aaic ave A AA9,3 ep ace 5/8 x11unc2B Gr B7 onne u s ova eat o ep acemen 5/8' 11unc 2B 62477 Gr B7

7. Description of Work: Replaced bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: g~ t5 2-E~

APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Detect '+ 19~

ne o Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

a / Commissions Inspector's Signature National Board, State, Providence and Endorsements

, 19~

PSL-I, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/12/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power & Light Co. PWO¹: 5074 6501 South Hwy. A I A WO ¹: 95028672 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdentificationofSystem: Feedwater Type Code Symbol Stamp N/A MV 09 13 Authorization No. N/A (b) Component Identification:

(Mark Number) Expiration Date N/A (c) Code Class: 3

) Applicable Construction Code and Addenda: ASME Sect III 1989 Ed/No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification of Stamped Material Replacement (Y or N) onnet uts aci ic a ve ep ace 5/8' 11unc 2B GR7 onnet uts ie Ut ot eat no ep acement 5/8' 11unc 2B L63812 GR7 Bonnet tu s Paciic a e ep ace 5/8' 11unc 2B Gr B7 honnnet ate s Nova eat o 93 ep acement 5/8 x11unc2B 62477 Gr B7

7. Description of Work: Replaced bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORII NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservlce leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: PRM 9S - ZS 8'5 APPLiCABLE MANUFACTURE'S DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed /wn r or Owner's Designee, Title Date ~(., 9~ 1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle f/8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

c aLd Commissions Inspector's Signature National Board, State, Providence and Endorsements

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of thc ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501. South Hwy. AIA P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By; 'lorida Power & Light Co. PWO¹: 2305 6501 South Hwy. A1A WO ¹: 95000522 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 8 Volume Control Type Code Symbol Stamp N/A V2500 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: ASME Sect III 1989 Edition/No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped OI'eplacement Material (Y or N) ange ut aw ep ace 5/8 x11unc28 Gr2H ange ut le ut ot ea o 94 ep acement 5/8 x11unc28 L63812 GR 7"'

ange tu aw ESKi05 ep ace 5/8 x11unc2A Gr 87 ange u ova a ine ea o Rep acement 5/8 x11unc2A 8099572 Gr 87

7. Description of Work: Replaced flange bolting due to corrosion.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2

~ VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: fYl MO,Q -X3 lQ, APPLiCABLE MANUFACTURE'S DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Dele ~~4~) ebe e 19~7 ner or ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

.)

Commissions inspector's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of 3 Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 009-293M
3. Work Performed By: Florida Power & Light Co. PWO¹: 4092 6501 South Hwy. A1A WO ¹: 95012783 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical & Volume Control Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V2551 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 3 (a) Applicable Construction Code and Addenda: ASME Sect III 1986 Ed / No Add. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Y or N) ave ssem y arway ep ace 2'lobe GR F316 ave ssem y n or a ing ena o 993 Rep acement 2 Globe SN-E-T516-74 GR F316 Ipe aw ep ace 2 Sch 80 316 TP304 Ipe ioga ipe eat o ESA 376 ep acement 2 Sch 80 Kobe Steel V40407 TP 304 2000 e rave er 021 i er ep acement Socket Weld 95-3574 ER 308 2 e rave er i er ep acement Socket Weld 95-3573 ER 308

7. Description of Work: REPLACE 2" CHECK AS PART OF VALVE UPGRADE. EXISTING WELDS REPLACED.
8. Tests Conducted: Hydrostatic Other: VT1 VT2~

Pneumatic VT3

~

Nominal Operating Pressure (ISLT) psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL FORM NIS-2 (Back) Sheet 2 of 3

9. Remarks: A satisfactory hydrostatic test was performed and witnessed by a VT-2 certified inspector D5~ W~> O<P@~ 4 QIX B
10. Inspection Report Numbers:

APPLICABLE MANuFACTURFS DATAREPORTS To BE ATTACHED Certificat of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ner or ner's Designee, Title Cate ~gigV . Ig~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desoibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectols Signature National Board, State, Providence and Endorsements Date 6 . 19~<

PSL-I, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PL SUPPLEMENTAL SHEET

1. Owner: Florida Power & Light Co. Date: 4j22Jg4 P.O. Box 529100 Miami, FL 33152 Sheet: 3 of 3
2. Plant: St. Lucie Plant Unit ¹: 2 6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA
3. Work Performed By: Florida Power & Light Co. PCM ¹: 009-293M 6501 South Hwy. A1A
6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced ASME Name of Name of Manufacturer Other Year Serial or Heat Board Repaired Code Component Manufacturer Identification Built No. No. or Stamped Replacement PorN) e rave er i er ep acemen Socket Weld 95-3572

FORM NPV-1 CERT1FICATE HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Provisions of the ASME Cade. Section ill. Division 1 Pg. of I. Manufactured and certified by Anchor/Darl ing Va 1 ve Co., 701 First Street, Wi 1 1 i amsport, PA 17 (name snd sddtess ot N Cenificste Hoidetl M f d f, Fl ori da Poive r iz Li qht Co ., P . 0. Bo'x 029950, Mi ami, FL (name sna aadress ot Purcnsser or awnerl 33102-9950 3 .,,..,St.Lucie Plants, 6501 South A1A, Jensen Beach, FL 34957 Iname sna aaatessl Gb N/A

4. Model No.. Series No., or Type orawing W93239 Rev. cRN
5. ASME Code. Section ill, Division I: 1986 (edioonl Ieadenaa aatel (cfassr (Code Case no.l Val ve B. Pump or valve Nominal inlet size Outlet size (In.l (in.l
7. Material: Body Bonnet N A lal ib) lc) ld) Iel Cert. Nat'I Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

E-T516- -4 MT.¹34735

'uooiementa( informahon in form of lists. sketches. or drawings msv be used oroinasd (ll size is 8yi x 11. I2) infonnaoon in items I through 4 on this asia Reoott ts inciuaaa on escn shear. (3) each sneet is numoerea snd the number Of Sheets is recoraad st the top at this form.

(12/86I This form (6000371msv be obtained tram the atder aeot.. ASME. 22 taw arive. 8ox 2300. Fsirfield. NJ 07007-2300.

PSL-1, NIS-2 TRACKING NO. S L-2 97 FORM NIS-2 OWIAVERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co.

P. O. Box 529100 Miami, FL 33152 Date: 02/01/96 Sheet:

Unit: 2 1

'f 2

2. Plant St. Lucie Nuclear Plant P.O. ¹: N/A 6501 South Hwy. A1A PCM ¹: N/A Jensen Beach, FL 34957 NPWO ¹: 8218
3. Work Performed By: Florida Power & Light Co. WO ¹: 95032001-1A 6501 South Hwy. A1A WCD N/A Jensen Beach, FL 34957
4. (a) Identification of System CCW Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification SUPPORT CW-3002-152 Expiration Date N/A (Mark Number)

(c) Code Class: N/A (SUPPORT FOR CLASS 3 SYSTEM)

5. (a) Applicable Construction Code and Addenda: ANSI B31.1 1977 ED. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1973 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material 'No. No. Replacement (Y or N)

'ANGLE - A36 5" X 5" X 3/8" N/A NIA NIA NIA REPLACED ANGLE A36 HEAT ¹ UTC 381833 5" X 5" X 3/8" HUB INC. 89180 N/A RIR 4R4590 1985 REPLACEMENT ANGLE - A36 3" X 3" X 1/4" N/A NIA NIA N/A NIA REPLACED NO ANGLE - A36 INTERSTATE UTC 379177 3" X 3" X 1/4" STEEL F7116 N/A RIR 4R-2876 1983 REPLACEMENT NO

7. DESCRIPTION OF WORK: VALVEI-TCV-144B, VALVE EXTENSION STEM WAS MISALIGNED TO VALVE DUE TO AN ORIGINAL INSTALLATIONPROBLEM. THE ENTIRE SUPPORT NEEDED TO BE MOVED TO ALLOWVALVESTEM REALIGNMENT.

8.. Test Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure (ISLT) []

Other: VT1 [] VT2[] VT3 [X] PSIG Test Temp. F Hold Time

PSL-1, NIS-2 TRACKING NO. S L 8 - 97 FORM NIS-2 (Back) Sheet 2 of

9. Remarks FINAL INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
10. Inspection Report Numbers: MM96-161 APPLICABLE MANUFACTURERS DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [X ] Repair [ ] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Signed Owners or Ow I's DB Ree, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. S L 8 - 98 FORM NIS-2 OWNWERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Florida Power & Light Co. Date: 12/11/95 P. O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant St. Lucie Nuclear Plant P.O. f/: N/A 6501 South Hwy. A1A PCM f/: 190-295 Jensen Beach, FL 34957 NPWO f/: 9105
3. Work Performed By: Florida Power & Light Co. WO ff: 95033072-01 6501 South Hwy. A I A WCD f/0271 Jensen Beach, FL 34957
4. (a) Identification of System BOILER FEEDWATER Type Code Symbol Stamp N/A Authorization No. N/A (b) Component Identification SUPPORT BF-4007-7008 Expiration Date N/A (Mark Number)

(c) Code Class: N/A (SUPPORT)

5. (a) Applicable Construction Code and Addenda: ASME 1974 S 1974 ADD. Code Case: N/A (b) Applicable Edition of Section XI for Repairs and Replacement Components: 1989 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Code Component or Manufacturer Serial or Heat Board Identification Built Repaired or Stamped Material No. No. Replacement (Y or N)

CAP SCREW A325 3/4"-10UNC2A X 2 ALLIEDNUT UTC 378011 1/2" AND BOLT CO. B02156 N/A RIR 3AD4723 1991 REPLACEMENT NO A194 GR. 2H NUT, HEAVY HEX ALLIEDNUT UTC 377944 3/4"-10UNC 2B AND BOLT CO. B47139 N/A RIR 3AH-2141 1993 REPLACEMENT

7. DESCRIPTION OF WORK: GAPPING, LOOSE BOLTING AND SIGNS OF RUBBING WERE IDENTIFIED DURING AN ENGINEERING WALKDOWN. PCM 190-295 WAS GENERATED TO REPLACE THE BOLTING WITH A LARGER DIAMETER, HIGHER STRENGTH BOLTING .
8. Test Conducted: Hydrostatic [ ] Pneumatic [] Nominal Operating Pressure (ISLT) []

VT2[] VT3 [X] Test Temp. oF Other: VT1 [] PSIG Hold Time

PSL-1, NIS-2 TRACKING NO. S L 8 - 98 FORM NIS-2 (Back) Sheet 2 of

9. Remarks FINAL INSPECTION WAS SUCCESFULLY PERFORMED BY A VT3 CERTIFIED Q.C. ISNPECTOR.
10. Inspection Report Numbers: M95450 APPUCABLE MANUFACTURERS DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this [ ] Repair [ X] Replacement conforms to the rules of the Asme Code,Section XI.

Type CodeSymbol Stamp: N/A Certificate of Authorization No N/A Owners or Owne Desi Be, Title Date I~I [~, 19 ~S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Arkwright Mutual Insurance Company have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 5/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectors Signature National Board, State, Providence and Endorsements Date 19 /d

PSL-S, NIS-2 TRACKING NO. SL-2-S-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/2/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 4413 6501 South Hwy. A1A WO ¹: 9501703 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Chemical 8 Volume Control Type Code Symbol Stamp N/A V2555 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 (a) Applicable Construction Code and Addenda: ASME SEC. III,1977 ED., 77 ADDEN. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped ol'eplacement Material (Y or N) eat o ep acement HT 306778

7. Description of Work: REPLACE PLUG/STEM ASSEMBLY DUE TO SEAT LEAKAGE.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT 2 VT 3 . psig Test Temp. 'F

PSL-2, NIS-2TRACKING NO. SL-2 099 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: 6AM CI 6 - R O'C'~

APPLICABLE MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ( Date~ I,19 )S er o wnei's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com¹60 Inspector's Signature National Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. SL-2 ~100 g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS F As Required by thc Provisions of thc ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 12/8/95 P.O. Box 529100 Sheet: 1 of Miami FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: N/A Jensen Beach, FL 34957 PCM¹: N/A
3. Work Performed By: Florida Power & Light Co. PWO ¹: 3624 6501 South Hwy. A1A WO ¹: 94025081 Jensen Beach, FL 34957 CWO ¹: N/A Process Sheet: N/A
4. (a) Identification of System: Safety Injection Type Code Symbol Stamp N/A V3211 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2 a) Applicable Construction Code and Addenda: ASME SEC. III; 1974 EDITION Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N) 3/4" - 10 UNC 2A ALL ALLIED HEAT ¹; NA SA 193; GRADE Replacement N THREAD 88147-GP 87 3/4-10 UNC 28 ALLIED HEAT ¹: NA SA 194, GRADE Replacement NUTS 604277 2H

7. Description of Work: REPLACE INLET FLANGE BOLTS (2 EA.) DAMAGED DURING REMOVALOF VALVE.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT) X Other: VT1 VT2 X VT3 ~psig TestTemp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 100 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: N i~ ( 6 0 [35 APPUCABLE MANUFACTURES OATA REPORTS To SE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed Y4 4 vmer SR P Ovmer's Designee, Title Date~ 19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 Ins ectoi's signature National Board, State, Providence and Endorsements Date , 19 9.(

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 12/6/95 P.O. Box 529100 Sheet: I of 3 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO¹: 4287 6501 South Hwy. A I A WO¹: 95016029 1A Jensen Beach, FL 34957 95016029 01 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Main Steam Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V8201 ( S/N 59335-00-0001)

V8207 ( S/N 59335-00-0007) Expiration Date N/A Identification:

(Mark Number) V8208 ( S/N 59335-00-0008)

(c) Code Class: 2 V8211 ( S/N 59335-00-0011)

V8213 ( S/N 59335-00-0013)

ASME Sect lil 1974 Ed / No Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Y or N)

Isc nsert rosy a e ena o 4 ep ace (V8211) N 91608-334026 Gr651 isc nsert rosy a e aena aa 458 99 ep acement (V8211) N91 608-344027 Gr651

>sc nsert ros y ave ena o NA $ TA4S8 ep ace (V8201) N 91608-31-0014 Gr651 isc nsert ros y ave ena o 8 992 ep acement (V8201) N91608-34-0030 Gr651 pm e ssy ros y ave ena o 93 ep ace (V8201) K5720 84841 26 Gr 86 pin e ssy ros y ave ena o 93 1995 ep acement (V8201) K57208<94119 Gr 86

7. Description of Work: Replaced disc inserts and spindle assemblies on listed valves.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2~ VT3 psig Test Temp. 'F

0 PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 3

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers:

APPLICABLE MANUFACTURES DATAREPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed I 8er or uP 'SiL PLli er's Designee, Title SdPV IS 1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectoi's Signature National Board, State, Providence and Endorsements Date

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OiVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F PL SUPPLEMENTAL SHEET

1. Owner: Florida Power & Light Co. Date: 12/6/95 P.O. Box 529100 Miami, FL 33152 Sheet: 3 of 3
2. Plant: St. Lucie Plant Unit ¹:

6501 South Hwy. A1A Jensen Beach, FL 34957 P.O. ¹: NA

3. Work Performed By: Florida Power & Light Co. PCM ¹: NA 6501 South Hwy. A1A

, 6. Identification of Components Repaired or Replaced and Replacement Components:

National Replaced ASME Name of Name of Manufacturer Other Year Serial or Heat Board Repaired Code Component Manufacturer Identification Built No. No. or Stamped Replacement (Yor N) isc nse ros y ave ena o ep ace (V8208) N91 608-31-0012 Gr 651 isc nse ros y ave ena o ep acemen (V8208) N91 608-34-0031 Gr 651 pin e ssy ros y ave ena o ep ace (V8208) K57208-33-0419 Gr B6 pin e ssy ros y ave ena o ep acemen (V8208) K5720849-0117 Gr B6 isc nse ros y ave ena o ep ace (V8207) N 91608-31-0011 Gr 651 isc nse ros y ave ena o ep acemen (V8207) N91 608-34-0029 Gr 651 pin e ssy ros y ave ena o ep ace (V8207) K57208-38-0148 Gr B6 pin e ssy ros y ave ena o ep acemen (V8207) K57208<9-0121 Gr B6 isc nse ros y ave ena o ep ace (V8213) N 91608-31-0006 Gr 651 isc nse ros y ave ena o ep acemen (V8213) N 91608-34-0028 Gr 651 pin e ssy ros y ave ena o ep ace (V8213) K57208-38-0140 Gr B6 pin e ssy ros y ave ena o ep acemen (V8213) K5720849-0111 Gr B6

CROSBY VA l VK 6) BABK CO 8 PANY W II ENTHAM ~ MASS Q.C.AQUA FORM N-2 N OR NPT CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III, Division 1 Not to Exceed One Day'a Producdon Pg~of~

~ Manufactured and oertIIIed by Crosb Valve 8( Ga e Co. 43 Kendrick St. Wrentham MA 02 3 (name and addresa of certilicate holder) .

Man+act redfor Florida Power 8 Li ht C P.O.Box 029950 H ami L 02 (name and addresa of pllrchaser)

St.Lucie Plant PSL-972 6501 South A1A Jensen Beach FL 34957 (name and address)

(dra))vinyl na} (fMflspec no.) (tenace atrength} (CRH)

AS ME Code, Seeuon III 1974 NO 2 (ed Non) (addenda) (class)

Fabricated ln acoordance with Const. Spec. (Dlv. 2 only) Date (Ho.}

. Remarks:

'i I R j= -37'- 2

. tenn. nrtekneee gn.) kttn. dec)go thteknene gn.) t))h ID (rk hkk) length overall (L h kk)

. Whan applcable, Certificate Holders'ata reports are attached for each Item of this report National Natfc)nal Board No. Board Ho.

In Numerical Order In Numerical Order N91608-34-0028 (2) N91608-34-0029 (12)

(3) N91608-34-0030 (13)

(4) N91608-34-0031 (I4)

(6) (16)

(8) (18)

(9) (19)

10) (2o)
p. Design pressure psi Temp. 'F Hydro. test pressure at temp. F.

(when applicable)

CROSB F 4-=c~cc~Ms~$ W d. -g Q.C.-392 SHEE7 1 OF 2 FORM N-2, N OR NPT CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III, Division I - Not to Exceed One Day's Production

1. Manufactured and certified by (Name and Address of N Cert(f(cate Holder)
2. Manufactured for FLORIDA POWER & LIGHT CO.

(Name and Address of Purchaser or Owner)

3. Location of Installation ST.LUCIE (Name and Address) 4, DS-C-59335 REV.C 1995 (CRN) (Drawing No.) (Year Built)
5. ASTIVI A458 GR,651 REIVIAR S (Material Spec No.) (Tensile Strength)
6. Nom. Thickness(in.) Mln. Design Thickness Dia. ID Length Overall Inch Inch DF 7.

Design Pressure(PSI) Temperature Hydrostatic Test (psig) at oF (When applicable)

8. Fabricated in accordance with Const. Spec.(Div. 2 only) Revision Date (No.)
9. ASME Code,Section III, Division 1: 1974 NO (Edition) (Addenda Date) (Class) (Code Case No.)
10. Remarks TENSILE MIN:95 000
11. When applicable; Certificate Holders'ata reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance>> National Serial Number Board No. Serial Number Board No.

Numerical Order Numerical Order (1) N91 608-34-0027 (11)

(2) (12)

(3) (13)

(4) (14)

(6) ('l5) l6) (16)

(7) (17)

(8) (18)

(9) (19)

(10) (20)

Q.C.-392 Manufacturer Serial No. N91 608-34-0027 SHEE7 2 OF 2 CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this(these) conform to the rules of construction of the ASME Cade.Section III.

Date 2 S Signed (NptCertificate Holder) (Authorized Repr sentative)

Expires ~~~~

(Date)

CERTIFICATE OF DESIGN Design specification certified by" PE State Reg No.

Design Report Certified by'E State Reg No.

'Signature not required - list name only.

CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel of have inspected these items described in this Data Report on has fabricated these parts ar appurtenances in accordance with the ASME Code,Section III. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warrant, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from ar connected with this inspection.

Date 1B 1>.

Signed Commissions (Inspector) (Nat'I. Bd., State, Prov. and No.)

<<Factory Mutual Systems

/ ROSR r P

~ a<73Ol>

3 ag Io Q.C.-392 SHEET I OF 2

-2, N OR NPT CERTIFICATE IIOLMRS'ATAREPORT FOR IDENTICAI.NUCLZARPARTS AND APPURTENANCES I

As Requirsd by tire Provisions of drs AS<YE Cods, Sccnon III, Division - Not to Erossd One Day's Production

1. Manufactured sind certified by (Name and Address of N Certificate Holder)
2. Manufactured for FLORlDA POWER 5 LIGHT COMPANY JENSEN BEACH FL (Name and Address of Purchaser or Owner)
3. Locat(on of installation LUC(E STORES JE SEN BEACH L (Name and Address)
a. DS-C-69335 REV. C 1995 (CRNI (Drawing Na.) (Year Built)
6. ASME SA 193 GR. B6 110 000

{Material Spec No.) (Tensile Strength)

6. Nom. Thickness((n.) Min. Design Thickness Dia. ID Length Overall inch inch 7.

Design Pressure(PSI) Temperature Hydrostatic Test (psig) at oF

{When applicable)

8. Fabricated in accordance with Const. Spec.{Div. 2 only) - Revision Date (No.)
9. ASME Code, Section ill, Division 1: 1974 NO ADDENDA (Edit(an) (Addenda Date) (Class) {Code Case No.l

'l0. Remarks 1'l. When app{(cab(e, Certif(cate Holders'ata reports are attached for each item of this report:

Part ar Appurtenance Net(anal Part or Appurtenance National Serial Number Board No. Serial Number Board No.

Numerical Order Numerical Order K6720&%9%111 {11)

(2) K57208%9-01 17 (12)

(3) K67208%9%119 (13)

(a) K67208&9%121 (1a)

(5) ('l 6)

(8) (16)

(7) ('l7)

(8) {18)

(9) (19)

(10) (20)

Q.C.-992 Manufacturer Serial No. K5720&%9-0111 SHEET,2 OF 2 iR$1~& 0%+bCR4~~ m rrevaa~~~ s'aa'n~~

CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this(these) &PINO "E 4&SEMBIES l"ao3377(

conform to the rules of construction of the ASME Code,Section III.

Vog(g Date Signed (NptCertificate Holder) (Authorized Re esentative)

Expires ~E~

(Date)

CERTIFICATE OF DESIGN Design speclficatlon certified by'E State Reg No.

Design Report Certlfied by>>

PE State Reg No.

<<Signature not required - list name only.

CERTIFICATE OF SHOP INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel of have inspected these items described ln this Data Report on 19~5 and state that to the best of my knowledge and belief. the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code,Section III. Each part listed has been authorized for 'stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warrant, expressed or implied, concerning the component described ln this Data Report. Furthermore, neither the Inspector nor his employer shalt be liable ln any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 195' Signed Commissions (Inspector) (Nat'I. Bd.. State, Prov. and No.)

<<Factory Mutual Systems

PSLQ NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 11/29/95 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power & Light Co. PWO ¹: 3604 6501 South Hwy. AIA WO¹: 95002731 01 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V1200 Expiration Date ~

N/A Identification:

(Mark Number)

(c) Code Class: 1 Code Case: None

) Applicable Construction Code and Addenda: ASME Sect III 1974 Edition/ No addenda (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired . Code No. No. Identification or Stamped OI'aterial Replacement (Y or N) eie ave ros y ave ena o ep ace

( Code Safety) N59336-00-0003 Gr CF8M eie ave ros y ave ena o 30 99 ep acement

( Code Safety) N 5933641-0002 Gl CF8M

7. Description of Work: Replaced exisiting valve with new spare.

S/N 59336-01-002 (New valve)

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp.

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory insewice leakage test was performed and witnessed by a VT-2 certified inspector.
10. inepeoiionReportNombem: lnNR5 Q lip/p APPLICABLE MANUFACTURE'S DATAREPORTS To BE ATI'ACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signeo Sf'R.

ne or Puceol nei's Designee, Title v'. I 6I Date MCt/ '- f,19~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspactols Signature National Board, State, Providence and Endorsements Date

GROS BY YA LVE 8 GAGED CO M PALY W It KIITHAM MASS ~

O.C..CCC ~

IF 9XXa 1

FORM MV-1 FOR SAFETY ANG SAFEtY REI.IEF VALVES r<<quired by the provisions of the AsME Code Rules Pate~et I<> DATA REPORT Safety and Safety Relief ValveS

'l. Manufactured By eros valve IL ca e co. 43 rendrick street wrenthan Ka 02093 Name arx$ Address HB-BP-86 N28017 Model Mo. order Mo. Contract Gate Maticnsl aboard Mo.

2. Manufactured For = da o e Order No.

Name and Address Florida Power ie Light Co. P.O.Box 029950 Miami,FL 33102 Name and Addrcs

4. Location of Plant St.Lucie Stores-PSL-972 6501 South A1A Jensen Beach FL 34957
5. Valve Idcntif icaticn SPARE Serial No. N59336-01-0002 Graving No. DS-C-59336-1 Rev.

Type Saf et Orifice Size 1 ~ 531 Safety, Safety Relief, Pilot, Pover Actuated Inch Inch Inch Inch

6. Sct Pressure (PSIG) 2485 Desi ~ ' . 700 F Rated T~rature 0

F Scaeped Capacity 212 182 LBS HR Steam a 3 X Overpresure Biovdovn (Pslr) 15X of SP Kydroscacic Test (PSIC) Inlet 3750 Cpiece valve 750

7. The ceceriai ~ design, construction and vorkmanship c~ly vith AWE Code, Section III.

Class 1 calcic 1974 , Addenda Gate No ~ Case Mo.

Serial No. Material Specification

a. Castings ident i f ication including Type or Grade K60802-36-0009 Barnet N91530-35-0009 ASME SA105
b. Bar Sco and Forgings S~rt Rods Mottle N95969-32-0009 ASME SA182 Cr.F316 Gisc Insert Spring uashcrs K60807-82-001 3 N91531-40-0030 N91521-40-0026 Adjuct eng 6ol I N91532-38-0015 ASHE SA193 Gr ~ B6 spvesI e 'p 1 t K60806-39-0018 N91 527-39-'0020 AS)iE SA193 Gr ~ B6

i

~ ~

IFV>

P:Ice /5 7-Serial Ko. Katerial Specification Identif ication including Type or Grade sprf"g K60807-82-0013 NX3108-0018

d. Bolting Disc Holder K77785-31-0001 N91524-40-0020 ASME SB637 UNS N07718 Disc Bushin K777S5-31-0001 N91525-38-0020 Stellite No. 6B Bonnet Stud N93669 ASME 1 3 r 7 ue certify that the statanenta made in this report are correct.

Oate: 19~~ Signed Cros Valve 4 Ga e Co. By Kanufacturer Certificate of Authorization Ko. 1878 exp Se tember 30 ~ 1 995 CERTlF lCATE OF SROP lKSPECTLOK l, the undersigned, holding a valid comsission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Pass. and eeployed by Arkuri ht-Boston Nanufacturers Kutual insurance C have inspected the equipaent described in this Oata Report on c 19~> and state that to the best of ey knouledge and belief, the Karafacturer has constructed this equip.

aent in accordance uith the appL!cable Subsections of ASKE Section Ill.

By signed this certificate, neither the inspector nor his employer Wakes any uarranty, ex-pressed or is@lied, concerning the equipnent described in this Oata Report. furthermore, neitherj the inspector nor his eaployer shall be Liable in any aarncr for any personal injury or property t daaage or a loss of any kind arising frora or corrected uith this inspection.

Oate / 19 r Factory Kvtual Systea

'oacai ss ions r' . ~I l~

( inspector ) (Rational Board, State, province and Ko.)

PSL-g, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/28/95 P.O. Box 529100 Sheet: 1 of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA 3 Work Performed By'lorida Power & Light Co. PWO¹: 3606 6501 South Hwy. A1A WO ¹: 95002732 01 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A Authorization No. N/A (b) Component V1202 Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 1 a) Applicable Construction Code and Addenda: ASME Sect III 1974 Edition / No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code No. No. Identification or Stamped OI'aterial Replacement (Yor N) isc nse ros y ave eria o ep ace N 91526424022 Gr 651 isc sert rosy a e ea o 6 7 1 92 ep acement N 95970-344015 ozz e ros y ave ena o A 45 ep ace N91 523-374014 GR 651 ozz e ros y ave ena o A 62 ep acement N 95969-324006 F316

7. Description of Work: Replaced disc insert and nozzle.

(Valve S/N N59336-00-0005)

    • (Approved per PCM 41,7-291M )
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2,'IS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inser vice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: + +qg 3,9&~

APPUCABLE MANUFACTURES DATAREPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ~Pe LS l Date ne or wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Providence and Endorsernents Date

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNERIS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/28/95 P.O. Box 529100 Sheet: I of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 191-295M 1
3. Work Performed By. Florida Power & Light Co. PWO¹: 4301 6501 South Hwy. A1A WO ¹: 95015833 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Reactor Coolant Type Code Symbol Stamp N/A V1201 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 1 a) Applicable Construction Code and Addenda: ASME Sect III 1974 Edition / No Add Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped oi'eplacement Material (Y or N) pnng as er ros y pnng 8 ep ace Assembly Valve Washer ASME SA1 05 pnng as er ros y ena o p ng 689 ep acement Assembly Valve K60807-834015 Washer ASME SA1 05

7. Description of Work: SPRING 8 WASHER ASSEMBLY REPLACED BY WYLE DURING OVER HAUL.

(VALVES/N: N59336-00-0004)

8. Tests Conducted: Hydrostatic Other:- VT 1 VT 2 Pneumatic VT 3 psigNominal Operating Pressure (ISLT)

Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2rtt-FORIN NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: rArtigr0 Ct IIOC APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ne Owner's Designee, Title Date o" >8,19 ~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle If8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectoi's Signature National Board, State, Providence and Endorsements Date I 199a

PSL-1, NIS-2 TRACKING NO. SL-2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS FP As Required by the Provisions of the ASME Code Section XI

l. Owner: Florida Power & Light Co. Date: 11/30/95 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit:
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A I A P.O.¹: NA Jensen Beach, FL 34957 PCM ¹: 158-295M
3. Work Performed By: Florida Power & Light Co. PWO¹: 3614 6501 South Hwy. A1A WO ¹: 95002185 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Containment Spray Type Code Symbol Stamp N/A Authorization No. N/A (b) Component FCV-07-1 B Expiration Date N/A Identification:

(Mark Number)

(c) Code Class: 2 ASME Sect III 1974 Ed/No Add Code Case: None

) Applicable Construction Code and Addenda:

(b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code Of No. No. Identification Stamped OI'eplacement Material (Y or N) a ve ate a ves 4 ep ace Gr 316 a ve ate ooper n ustnes eat o 2 994 ep acement P-11534 Gr 316

7. Description of Work: Replaced valve gate due to wear.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure (ISLT)

Other: VT1 VT2 VT3 psig Test Temp. 'F

PSL-2, NIS-2 TRACKING NO. SL-2 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A satisfactory inservice leakage test was performed and witnessed by a VT-2 certified inspector.
10. Inspection Report Numbers: I'I/I MQ Q -Q+ 7+

APPLICABLE MANUFACTURES DATA REPORTS TO BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Repair

+ Replacement Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed M Acznk.Su/ Y'&( Cate ILINIS>

Own r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Inspectoi's Signature National Board, State, Providence and Endorsements Date 19 9a

PSL-2NIS-2 TRACKING NO. SL-2<- ~107 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power 4 Light Co. Date: 1/4/S6 P.O. Box 529100 Slieet' of Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA JensenBeach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power 4, Light Co. PWO¹: 5913 6501 South Hwy. A1A WO ¹: 95035159 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) IdentiTication of System: Safety Injection Type Code Symbol Stamp N/A HCV-3617 Authorization No. N/A (b) Component N/A Identification: Expiration Date (Mark Number)

(c) 'Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC.III, '1 ED.; W. '3 ADD.'ode Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification or Stamped Material Replacement (Yor N)

SEAL WELD FPL Sl-VALV-2007 SAQ79 TQ16 NA Replacement Weld

7. Description of Work: REMOVE/REINSTALLSEAL WELD TO FACILITATEVALVEWORK.
8. Tests Conducted: Hydrostatic Other: VTI Pneumatic VT2 X VT3 ~petg TeetTemp. ~'F Nominal Operating Pressure (ISLT) X

PSL-2, NIS-2 TRACKING NO. SL-2 ~107 FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: MM95-2614 APPUCABI.E MANUFACTURES DATA REPORTS To BE ATTACHED Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A signed 0

( ~ itiIIUTStePI/

or Owner's Designee, Title IS I Date t f 19 ~~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the OwneVs Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 inspectoVs Signature Natioriat Board, State, Providence and Endorsements Date

PSL-2, NIS-2 TRACKING NO. SL-2 ~1th r e FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: Florida Power & Light Co. Date: 2/6/96 P.O. Box 529100 Sheet: 1 of 2 Miami, FL 33152 Unit: 2
2. Plant: St. Lucie Nuclear Plant 6501 South Hwy. A1A P.O.¹: NA Jensen Beach, FL 34957 PCM¹: NA
3. Work Performed By: Florida Power & Light Co. PWO ¹: 5925 6501 South Hwy. A1A WO ¹: 95035220 Jensen Beach, FL 34957 CWO ¹: NA Process Sheet: N/A
4. (a) Identification of System: Feedwater Type Code Symbol Stamp N/A V0 9125 Authorization No. N/A (b) Component Identification: Expiration Date N/A (Mark Number)

(c) Code Class: 2

) Applicable Construction Code and Addenda: ASME SEC. III; 1974 ED. -,75 ADDEDA Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs and Replacement Components: 1989 Edition.

6. Identification of Components Repaired or Replaced and Replacement Components:

Type of Name of Manufacturer National Other Year Replaced ASME Component Manufacturer Serial or Heat Board Built Repaired Code or No. No. Identification Stamped oi'eplacement Material (Yor N)

ALLTHREAD ALLIEDNUT & BOL NA SA193 B7 1993 Replacement 3/4' 10 UNG-2A HEX NUTS ALLIEDNUT & BOL HT E04277 NA SA194 GR 2H Replacement 3/4-10 UNG 2B 1/Z HEX HEAD PLU TIOGA HT¹ 085K NA SA 105 Replacement

7. Description of Work: REPLACE BOLTING AND VALVE PLUG WHICH WERE REMOVED DURING INSPECTION OF VALVE.
8. Tests Conducted: Hydrostatic Other: VTI

~ Pneumatic VT2 X VT3 Nominal Operating Pressure (ISLT)

~pstg TestTemp. ~'F X

PSL-2, NIS-2 TRACKING NO. SL-2C- ~110 f,

FORM NIS-2 (Back) Sheet 2 of 2

9. Remarks: A SATISFACTORY INSPECTION FOR LEAKAGE WAS PERFORMED AND WITNESSED BY A VT 2 CERTIFIED INSPECTOR.
10. Inspection Report Numbers: MM95-2622 APPUCABLE MANUFACTURES OATA REPORTS To BE ATTACHEO Certificate of Compliance We certify that the statements made in the report are correct and this Repair X Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Signed ~g '3PV er's Designee, Title Date i2jD (e 19 R6 tNner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Florida and employed by Factory Mutual Engrg Assoc.

have inspected the components described in this Owner's Report during operating cycle ¹8 starting on 05/94, and state that to the best of my knowledge and belief, the Owner has performed examinations and and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. 1989 Edition, no addenda.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descibed in the Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB7719 FL Com ¹60 Inspectoi's Signature National Board, State, Providence and Endorsements Date 19 W6