Search by property

Jump to navigation Jump to search

This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.

Search by property

A list of all pages that have property "Title" with value "CR-3 License Transfer SE Corrected". Since there have been only a few results, also nearby values are displayed.

Showing below up to 26 results starting with #1.

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)


    

List of results

  • ML20101G582  + (CR-3 License Transfer SE Corrected Cover Letter)
  • 3F0486-02, CR-3 Pump Support Configuration Study  + (CR-3 Pump Support Configuration Study)
  • ML070780197  + (CR-PNP-----------, CR Just Entered, Operability of Refuel Bellows Seal Rupture Drain Leakage Alarm Switch)
  • ML070780412  + (CR-PNP-1990-01467, During Inspection of 2nd Pass FW-8 MT of Weld Revealed Indication 4 Long Crack- Like Linear)
  • ML070780416  + (CR-PNP-1990-09249, Torus Containment Shell One Area of Pitting Exceeding Acceptance Criteria of .066 Inches Base Depth)
  • ML070780367  + (CR-PNP-1996-00396, High Mitrate Levels Exists in the Tbccw System)
  • ML070780372  + (CR-PNP-1996-09593, Crack in Housing for MO-1001-34A)
  • ML070780418  + (CR-PNP-2000-09228, P-161C Suction Piping 98 Deg. Elbow for C Continuous SSW Hypo Pump Cracked and Leaking Into Burm Area)
  • ML070780431  + (CR-PNP-2001-02275, a SSW Discharge Piping 20 Foot Section of Rubber Lining Peeled Off of Piping Exposing Bare Metal)
  • ML070780439  + (CR-PNP-2001-04048, Received SBO DG Fuel Tank Leakage Alarm Alert Wet Probes)
  • ML070780453  + (CR-PNP-2001-04171, Alarm C190-D3 SBO DG Fuel Tank Leakage in Alarm)
  • ML070780491  + (CR-PNP-2001-04238, HCU 50-31 Leak)
  • ML070780508  + (CR-PNP-2001-04779, T- 112 Cation Regen Tank Found Second Leak)
  • ML070780529  + (CR-PNP-2001-09403, Fire System Has Broken Pipe Between 12-D-8, 12D-9 in Aog Building)
  • ML070780615  + (CR-PNP-2002-01411, Secondary Containment Leakrate Testing Was Aborted)
  • ML070780632  + (CR-PNP-2002-01414, the Concrete Shield Block for the Drywell Equipment Hatch Was Removed Prior to the Reactor Being Less than 212F)
  • ML070780545  + (CR-PNP-2002-09283, Unable to Reassemble E-122B, B Tbccw Heat Exchanger Head)
  • ML070780564  + (CR-PNP-2002-10639, Received Blackout Diesel Generator Alarm (C3L-A4) Several Times During Shift on 06/19/2005)
  • ML070780603  + (CR-PNP-2002-12941, P-208D (D Salt Service Water Pump) Shaft Had Pitting)
  • ML070780624  + (CR-PNP-2003-01413, Secondary Containment Leakrate Testing Was Aborted)
  • ML070780653  + (CR-PNP-2003-01471, Primary Containment Isolation Valve (PCIV) 262-F-013A Experienced Increased But Acceptable Local Leak Rate Test Results)
  • ML070790110  + (CR-PNP-2003-01582, Primary Containment Isolation Valve (PCIV) 6-CK-62B Failed to Meet Its Individual Valve Local Leak Rate Test (LLRT) Acceptance Criteria)
  • ML071560251  + (CR-PNP-2003-01618 with Supporting Report (with Redacted Notes) 1st Page for Inspector)
  • ML070790183  + (CR-PNP-2003-02976, Pilgrim Construction Activity and Damage to Underground Utilities)
  • ML070790161  + (CR-PNP-2005-02621, Rollup CR with Various Problems Inservice Inspection Related)