Originator: CONVERTED DATA Originator Group: CONVERTED DATA Supervisor Name: CONVERTED DATA Discovered Date: 05/22/1999 0O:OO Originator Phone: 0 Operability Required: N Reportability Required: N Initiated Date: 05/22/ 1999 0O:OO Condition

Description:

DURING UNDERWATER INSPECTION OF THE TORUS CONTAINMENT SHELL ONE AREA OF PITTING CORROSION EXCEEDS THE ACCEPTANCE CRITERIA OF.066 INCHES BASE DEPTH IN BAY #3 (NCR99-05)

Immediate Action

Description:

Suggested Action

Description:

EQUIPMENT:

Tag Name Tag Suffix Name Component Code Process System Code 50 REFERENCE ITEMS:

Type Code Description CONVERTED PR PR.99.9249 TRENDING (For Reference Purposes Only):

Trend Type Trend Code KEYWORDS MAINT RULE

I I

I 1

I ADMIN E n t w I CR-PNP-1999-09249 Initiated Date: 5/22/1999 0:OO Owner Group :Regulatory & Industry Affairs Staff Current

Contact:

SCREENING TEAM Current Significance: C - CORRECTION Closed by: SCREENING TEAM 5/29/1999 0:OO Summary

Description:

DURING UNDERWATER INSPECTION OF THE TORUS CONTAINMENT SHELL ONE AREA OF PITTING CORROSION EXCEEDS THE ACCEPTANCE CRITERIA OF.066 INCHES BASE DEPTH IN BAY #3 (NCR99-05)

Remarks

Description:

PR=EF CONTAINMENT TP99-010 NCR 99-05 MR19701280 CORROSION Closure

Description:

SEE EVALUATION RESPONSE.

Ent4qg-y 0512311999 0O:OO A S S I G N M E N T S CR-PNP-1999-09249

Entwm I

CORRECTIVE ACTION I CR-PNP-1999-09249 CA Number:

1

-,~

__l___l._

~ _I----

Name i

Group I

Assigned By: Regulatory & Industry Affairs Staff Assigned To: Regulatory & Industry Affairs Staff BRENNION, S.

Ellis,Douglas W Subassigned To :

Originated By: BRENNION, S.

Performed By: ELLIS, D.

Subperformed By:

Approved By:

Closed By: BRENNION, S.

5/22/1999 0O:OO:OO 5/25/1999 0O:OO:OO 5/25/1999 0O:OO:OO

~

~

~

Current Due Date: 05/30/1999 Initial Due Date: 05/30/1999 CA Type: GENERAL Plant Constraint: NONE CA

Description:

CONDUCT A 10CFR50.73 REPORTABILITY REVIEW

Response

Subresponse :

CONVERTED DATA Closure Comments:

MEMO DOCUMENTING RESULTS OF REPORTABILITY REVIEW

[05/25/99; S. BRENNION]

A 10CFR50.73 Reportability Evaluation has been performed for the condition involving pitting of Torus shell described in PR99.9249.00 resulting in a determination of NOT REPORTABLE under 10CFR50.73 (a)(2)(i), (v), and (vii) as well as (a)(2)(ii)