ML070780372

From kanterella
Jump to navigation Jump to search
CR-PNP-1996-09593, Crack in Housing for MO-1001-34A
ML070780372
Person / Time
Site: Pilgrim
Issue date: 11/27/1996
From:
Entergy Corp
To:
Office of Nuclear Reactor Regulation, NRC/OGC, NRC Region 1
References
CR-PNP-1996-09593
Download: ML070780372 (5)


Text

~

Entergy I CONDITION REPORT Originator: CONVERTED DATA Originator Group: CONVERTED DATA Supervisor Name: CONVERTED DATA Discovered Date: I 1/27/1996 0O:OO CR-PNP-199609593 Originator Phone: 0 Operability Required: N Reportability Required: N Initiated Date: 11/27/1996 0O:OO Condition

Description:

DURING SHOP WORK ON THE OLD MOV HOUSING FOR MO-1001-34A, A CRACK WAS FOUND ON ONE WPPER HOUSING FLANGE BOLT HOLE. THE ACTUATOR HOUSING WAS BEING REFURBISHED PER P2403876 FOR RE-USE AS MO-1201-85 IN RFO #I I.

Immediate Action

Description:

Suggested Action

Description:

EQUIPMENT:

Tag Name REFERENCE ITEMS:

TvPe Code CONVERTED PR Tag Suffix Name Component Code Process System Code 99 Description PR.96.9593

'I I

I 1

ADMIN CR-PNP-1996-09593 Initiated Date: 11/27/1996 0:OO Owner Group :CA&A Staff Current

Contact:

WALKER, J.

Current Significance: D - ADMIN CLOSE Closed by: WALKER, J.

12/4/1996 0:OO I

~

Summary

Description:

DURING SHOP WORK ON THE OLD MOV HOUSING FOR MO-1001-34A9 A CRACK WAS FOUND ON ONE UPPPER HOUSING FLANGE BOLT HOLE. THE ACTUATOR HOUSING WAS BEING REFURBISHED PER P2403876 FOR RE-USE AS MO-1201-85 IN RFO #11.

Remarks

Description:

MOV HOUSING MO-1001-34A P9403876 MO-1201-85 LIMITORQUE ACTUATOR Closure

Description:

EVALUATION COMPLIANCE REVIEW EVALUATION AND CORRECTIVE ACTION COMPLETE.

Entergy A S S I G N M E N T S Version: 1 Significance Code: D - ADMIN CLOSE Classification Code: NON-SIGNIFICm Owner Group: CA&A Staff Performed By: Shatas,Albert A Assignment

Description:

SCREEN IAW NOP92A1 CR-PNP-1996-09593 11/27/1996 0O:OO

Enterrrv CORRECTIVE ACTION I CR-PNP-1996-09593 I

CA Number:

1

- - _- I__

l__ __I

~

r-SHATAS, A.

Shatas,Albert A Group I

Name Assigned By: CA&A Staff Assigned To: CA&A Staff Subassigned To :

~

Originated By: SHATAS, A.

Performed By: SHATAS, A.

Subperformed By:

Approved By:

Closed By: SHATAS, A.

11/27/1996 0O:OO:OC 11/27/1996 0O:OO:OC 11/27/1996 0O:OO:OC Current Due Date: 12/04/1996 CA Type: GENERAL Plant Constraint: NONE CA

Description:

SCREEN IAW NOP92A1

Response

Subresponse :

CONVERTED DATA Closure Comments:

PAC APPROVED NOP92A1 EXHIBIT 3 Initial Due Date: 12/04/1996

CORRECTIVE ACTION I CR-PNP-1996-09593 CA Number:

2 r - - -

Name I

KEENE, J.

Haladyna,Robert A Assigned By: Regulatory & Industry Affairs Staff Assigned To: Regulatory & Industry Affairs Staff Subassigned To :

Originated By: KEENE, J.

Performed By: HALADYNA, R.

Subperformed By:

Approved By:

Closed By: KEENE, J.

11/27/1996 0O:OO:OC 12/30/1996 0O:OO:OC 12/30/1996 0O:OO:OC Current Due Date: 12/10/1996 Initial Due Date: 12/10/1996 CA Type: GENERAL Plant Constraint: NONE CA

Description:

CONDUCT A 10CFR50.73 REVIEW FOR THE CONDITIONS IDENTIFIED IN THIS PROBLEM REPORT.

Response

Subresponse :

CONVERTED DATA Closure Comments:

COMPLETE 10CFR50.73 REVIEW.

10 CFR 50.73 REPORTING APPLICABLE? NO BASIS: THE PROBLEM REPORT IS NOT REPORTABLE BECAUSE IT DID NOT MEET THE REPORTING THRESHOLD ESTABLISHED IN 10CFR50.73 AND IT IS NOT A REPEAT OCCURRENCE. THE PROBLEM WAS EVALUATED REGARDING POSIBLE OVERTHRUST OF VALVE MO-100 1 -34A WHILE THE HOUSING OPERATOR WAS INSTALLED ON MO-1001-34A. IN

SUMMARY

, THE EVALUATION CONCLUDED THERE WAS NO ADVERSE IMPACT ON VALVE MO-1001-34A WHILE THE OPERATOR WAS INSTALLED ON MO-1001-34A.

(NCR 96-44 ALSO DOCUMENTED THE PROBLEM FOR MO-1201-85).