Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20087A118 + (ML20087A118)
- ML20087A120 + (ML20087A120)
- ML20087A122 + (ML20087A122)
- ML20087A124 + (ML20087A124)
- ML20087A125 + (ML20087A125)
- ML20087A131 + (ML20087A131)
- 05000281/LER-1976-003, Updated LER 76-03/01T:on 760521,routine Chemistry Analysis of Primary Coolant Boron Concentration Indicated Unplanned Dilution Occurred.Caused by Three Tubes Cut on Steam Generator 2A.Tubes Plugged + (ML20087A133)
- ML20087A136 + (ML20087A136)
- 05000281/LER-1976-003-01, /01T:on 760521,routine Chemistry Analysis of Primary Coolant Boron Concentration Indicated Unplanned Dilution Occurred.Caused by Three Tubes Out on Steam Generator 2A.Tubes Plugged + (ML20087A138)
- ML20087A141 + (ML20087A141)
- ML20087A146 + (ML20087A146)
- 05000280/LER-1976-003-01, /01T:on 760721,discovered Outputs of Two Pressure Switches PS-LM-100C & 100D Still Jumpered to Prevent Initiation of Cls Containment Hi Signal.Caused by Failure to Review Jumper Log at Proper Time + (ML20087A147)
- 05000281/LER-1976-002-01, /01T:on 760511,small Cracks & Radial Growth Observed on Periphery of Seventh Tube Support Plate.Caused by Change from Phosphate to Avt Chemistry.Further Investigation in Progress + (ML20087A149)
- 05000280/LER-1976-002, Updated LER 76-02/01T:on 760313,determined Worst Break LOCA Core Thermal Transient Analysis Inaccurate Since Effects of Steam Generator Tube Plugging on LOCA Not Considered + (ML20087A151)
- ML20087A152 + (ML20087A152)
- ML20087A153 + (ML20087A153)
- 05000280/LER-1976-002-01, /01T:on 760313,determined That Worst Break LOCA Core Thermal Transient Analysis Inaccurate Since Effects of Steam Generator Tube Plugging Not Included.Cause Unknown. Research Being Conducted + (ML20087A155)
- ML20087A156 + (ML20087A156)
- ML20087A161 + (ML20087A161)
- ML20087A162 + (ML20087A162)
- ML20087A164 + (ML20087A164)
- ML20087A166 + (ML20087A166)
- 05000281/LER-1976-009-99, /99T:on 760204,main Steam Line Trip Valve TV-MS-201A Failed to Closed When Operated from Control Room. Caused by Valve Disc Binding Against Valve Body.Disc Opening Adjusted + (ML20087A167)
- ML20087A168 + (ML20087A168)
- ML20087A169 + (ML20087A169)
- ML20087A171 + (ML20087A171)
- ML20087A174 + (ML20087A174)
- ML20087A177 + (ML20087A177)
- ML20087A179 + (ML20087A179)
- ML20087A181 + (ML20087A181)
- ML20087A185 + (ML20087A185)
- ML20087A190 + (ML20087A190)
- ML20087A195 + (ML20087A195)
- ML20087A198 + (ML20087A198)
- 05000272/LER-1981-059, Supplemental LER 81-059/01X-01:on 810616,during Initial Testing,Auxiliary Feedwater Pump 23 Turbine Steam Supply Check Valves 21MS46 & 23MS46 Found Damaged Internally.Caused by Steam Flow Sys Oscillations + (ML20087A203)
- ML20087A205 + (ML20087A205)
- ML20087A206 + (ML20087A206)
- ML20087A211 + (ML20087A211)
- ML20087A215 + (ML20087A215)
- ML20087A220 + (ML20087A220)
- ML20087A226 + (ML20087A226)
- ML20087A229 + (ML20087A229)
- ML20087A230 + (ML20087A230)
- ML20087A242 + (ML20087A242)
- RC-95-0183, Requests Amend to License NPF-12,consisting of TS Change 95-09 Re TS 3/4.3.2 ESFAS Instrumentation,Sr 4.3.2.1 Being Revised to Exclude Requirement to Perform Slave Relay Test of 36 Containment Purge Supply & Exhaust Valves Quarterly + (ML20087A245)
- ML20087A251 + (ML20087A251)
- ML20087A254 + (ML20087A254)
- ML20087A257 + (ML20087A257)
- ML20087A258 + (ML20087A258)
- ML20087A260 + (ML20087A260)
- ML20087A268 + (ML20087A268)