LIC-98-0160, Special Rept:On 981113,MSL RM RM-064 Was Declared Inoperable Due to Leakage Past Isolation Valve HCV-922.Troubleshooting Has Indicated That Leakage Has Stopped & Cause of Leak Continues to Be Investigated25 November 1998Special Rept:On 981113,MSL RM RM-064 Was Declared Inoperable Due to Leakage Past Isolation Valve HCV-922.Troubleshooting Has Indicated That Leakage Has Stopped & Cause of Leak Continues to Be InvestigatedPost Accident Monitoring
LIC-97-0133, Special Rept:On 970805,main Steam Line Radiation Monitor, RM-064,declared Inoperable Due to Leakage Past Isolation Valve HCV-922.Plant Maint Document,Mwr 9702939,written to Track Repairs.Next Refueling Outage Scheduled for 98032119 August 1997Special Rept:On 970805,main Steam Line Radiation Monitor, RM-064,declared Inoperable Due to Leakage Past Isolation Valve HCV-922.Plant Maint Document,Mwr 9702939,written to Track Repairs.Next Refueling Outage Scheduled for 980321Post Accident Monitoring
LIC-97-0036, Special Rept:On 970321,excessive Grease Voids Were Found in Helical Wall Tendons on Containment Tendon Prestressing Sys.Insp Has Been Conducted21 March 1997Special Rept:On 970321,excessive Grease Voids Were Found in Helical Wall Tendons on Containment Tendon Prestressing Sys.Insp Has Been Conducted
LIC-95-0128, Special Rept:On 950605,monitors RM-062 & RM-063 Removed from Svc to Allow Installation of Mod MR-FC-84-155C & Engineering Change Notice 94-567 on RM-062.RM-063 Expected to Be Operable by 95063019 June 1995Special Rept:On 950605,monitors RM-062 & RM-063 Removed from Svc to Allow Installation of Mod MR-FC-84-155C & Engineering Change Notice 94-567 on RM-062.RM-063 Expected to Be Operable by 950630
LIC-94-0107, Special Rept:On 940420,fire Protection Impairment Permit Initiated to Address Inoperability of Fire Detectors. Appropriate Compensatory Measures Will Remain in Place for Duration of Impairment27 May 1994Special Rept:On 940420,fire Protection Impairment Permit Initiated to Address Inoperability of Fire Detectors. Appropriate Compensatory Measures Will Remain in Place for Duration of ImpairmentHourly Fire Watch
LIC-94-0050, Special Rept:On 940120,discovered That Seal Around Penetration 56E-F-331 Degraded Due to Time Required to Repair Penetration Seal.Penetration Returned to Functional Status & Fpip 3776 Closed25 February 1994Special Rept:On 940120,discovered That Seal Around Penetration 56E-F-331 Degraded Due to Time Required to Repair Penetration Seal.Penetration Returned to Functional Status & Fpip 3776 ClosedFire Barrier
Continuous fire watch
Hourly Fire Watch
ML20063H4348 February 1994Special Rept:On 931210,discovered Discrepancy in Three Impellers Purchased by Util to Be Used on Byron Jackson Type 28RXL VC Two Stage Pump.Impellers Shipped to Bw/Ip for Evaluation
LIC-94-0028, Special Rept:On 931222,diesel Driven Fire Pump FP-1B Declared Inoperable After Pump Failed to Start While Conducting Procedure OP-ST-FP-001.Replacement Starter Procured,Installed & Declared Operable on 94010621 January 1994Special Rept:On 931222,diesel Driven Fire Pump FP-1B Declared Inoperable After Pump Failed to Start While Conducting Procedure OP-ST-FP-001.Replacement Starter Procured,Installed & Declared Operable on 940106Fire Barrier
Continuous fire watch
Hourly Fire Watch
LIC-93-0305, Special Rept:On 931129,Fire Protection Impairment Permit (Fpip) 3699 Initiated for Motor Driven Fire Pump FP-1A & on 931203,FPIP 3702 Initiated for FP-1A.Pump Has Since Been Returned to Operable Status & Fpips 3699 & 3702 Closed5 January 1994Special Rept:On 931129,Fire Protection Impairment Permit (Fpip) 3699 Initiated for Motor Driven Fire Pump FP-1A & on 931203,FPIP 3702 Initiated for FP-1A.Pump Has Since Been Returned to Operable Status & Fpips 3699 & 3702 ClosedFire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
LIC-93-0292, Special Rept:On 931026,Fire Protection Impairment Permit (Fpip) 3619 Initiated for Containment Fire Detection Zone 17 to Support Troubleshooting & Repair of Zone 17 Detector.Fire Watch Established Until Affected Zones Cleared9 December 1993Special Rept:On 931026,Fire Protection Impairment Permit (Fpip) 3619 Initiated for Containment Fire Detection Zone 17 to Support Troubleshooting & Repair of Zone 17 Detector.Fire Watch Established Until Affected Zones ClearedFire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
LIC-93-0282, Special Rept:On 931015,fire Protection Impairment Permit 3560 Initiated for Fire Door 1007-11 in Order to Support Work Associated W/Mod of Radiation Monitors.Door Returned to Functional Status & Fpip 3560 Closed on 93102918 November 1993Special Rept:On 931015,fire Protection Impairment Permit 3560 Initiated for Fire Door 1007-11 in Order to Support Work Associated W/Mod of Radiation Monitors.Door Returned to Functional Status & Fpip 3560 Closed on 931029
LIC-93-0272, Special Rept:On 930928,Containment Penetration E-11 Was Breached to Support Installation of Test Flange for SG Eddy Current Testing.Impairment Permit 3457 Generated,Fire Watch Established.Eddy Current Testing Completed 9310304 November 1993Special Rept:On 930928,Containment Penetration E-11 Was Breached to Support Installation of Test Flange for SG Eddy Current Testing.Impairment Permit 3457 Generated,Fire Watch Established.Eddy Current Testing Completed 931030Fire Barrier
Fire Watch
Hourly Fire Watch
LIC-93-0243, Special Rept:On 930823 & 28,Fire Protection Impairment Permits 3364 & 3374 Initiated for Fire Barrier Penetrations 81-F-17 & 56-F-234,respectively,to Support Maint on Portable Water Sys.Penetrations Returned to Service on 93090724 September 1993Special Rept:On 930823 & 28,Fire Protection Impairment Permits 3364 & 3374 Initiated for Fire Barrier Penetrations 81-F-17 & 56-F-234,respectively,to Support Maint on Portable Water Sys.Penetrations Returned to Service on 930907Fire Barrier
Continuous fire watch
Fire Watch
LIC-92-0267, Special Rept:On 921029,foam Removed from Surface of Fire Barrier Penetration 77-F-282 in Support of Electrical Maint. Appropriate Compensatory Measures in Place Prior to Removal of Foam & Until Seal Repaired & Returned to Operability20 November 1992Special Rept:On 921029,foam Removed from Surface of Fire Barrier Penetration 77-F-282 in Support of Electrical Maint. Appropriate Compensatory Measures in Place Prior to Removal of Foam & Until Seal Repaired & Returned to OperabilityFire Barrier
Continuous fire watch
Hourly Fire Watch
ML20116K78310 November 1992Special Rept:On 920928,Halon Fire Suppression Sys for Cable Spreading Room Removed from Svc & Not Restored to Operable Status within 14 Days.Caused by Need to Perform Mod to Upgrade Sys.Compensatory Measures in Place
ML20118A36625 August 1992Special Rept:On 920720,fire Barrier Penetration Seals 81-E-7 & 81-E-8 Discovered Damaged & Declared Inoperable.On 920728, Fire Barrier Between Corridor 52 & Technical Support Ctr Declared Inoperable.Compensatory Measures in PlaceFire Barrier
Continuous fire watch
Hourly Fire Watch
ML20102A53221 July 1992Speciat Rept:On 920615,Fire Door 1007-19 Damaged & Declared Inoperable Due to Rip in Skin of Door Caused by Cart. Appropriate Compensatory Measures,Per TS 2.19(7) Instituted During Impairment.Door Repaired & Returned to Svc on 920624Fire Barrier
Hourly Fire Watch
ML20096D90811 May 1992Special Rept Re Excessive Grease Voids Found in Dome & Helical Wall Tendons of Containment Tendon Prestressing Sys. Addl Actions Are Planned for 1996 Surveillance.Grease Void Measurements Encl
ML20095A78115 April 1992Special Rept:On 920309,fire Barrier Between Room 81 & Turbine Bldg Damaged & Declared Inoperable.Replacement Door Shipped W/O Required Qualification Documentation Therefore Installation Delayed.Installation Completed by 920430Fire Barrier
Fire Watch
Hourly Fire Watch
ML20094K05313 March 1992Special Rept:On 920218,fire Barrier Between Corridor 4 & Room 21 Breached by Removal of Floor Plug to Support Installation Mod.Fire Barrier Remains Breached at Present & Will Be Restored by End of 1992 Refueling OutageFire Barrier
Continuous fire watch
Hourly Fire Watch
ML20090A31024 February 1992Special Rept:On 920116,0130,0205,07 & 08,listed Fire Protection Equipment Inoperable for More than 7 Days. Required Compensatory Measures Will Remain in Place Until Equipment Functional or Documentation LocatedFire Barrier
Continuous fire watch
Hourly Fire Watch
ML20091P79428 January 1992Special Rept:On 920117,wide-range Noble Gas Stack Monitor RM-063M for post-accident Monitoring Declared Inoperable & Not Returned to Operable Status within 7 Days.Caused by Faulty Mechanical Switch.Maint Work Order Issued
LIC-91-0277, Special Rept:On 911023,barrier Penetration 19-E-39,between Room 19 & Turbine Bldg,Breached to Support long-term Maint on Component Cooling Water Hxs.Compensatory Measures Implemented.Barriers Will Be Restored Prior to 92013125 November 1991Special Rept:On 911023,barrier Penetration 19-E-39,between Room 19 & Turbine Bldg,Breached to Support long-term Maint on Component Cooling Water Hxs.Compensatory Measures Implemented.Barriers Will Be Restored Prior to 920131Fire Barrier
Continuous fire watch
Hourly Fire Watch
LIC-91-0099, Ro:On 910819,fire Door 1007-9 Found to Not Have Ul Label Certifying Its Fire Rating.Door Declared Inoperable. Evaluation of Door Added to Scope of Ongoing Fire Barrier Upgrade Program.Program Completion Scheduled for June 199220 September 1991Ro:On 910819,fire Door 1007-9 Found to Not Have Ul Label Certifying Its Fire Rating.Door Declared Inoperable. Evaluation of Door Added to Scope of Ongoing Fire Barrier Upgrade Program.Program Completion Scheduled for June 1992Fire Barrier
Continuous fire watch
Hourly Fire Watch
LIC-91-0097, Supplemental Special Rept:On 910610,wide Range Noble Gas Stack Monitors Found Inoperable Due to Excessive Circuit Noise on Signal Line Interferring W/Automatic Switching Function.Time Relay Item Repaired15 August 1991Supplemental Special Rept:On 910610,wide Range Noble Gas Stack Monitors Found Inoperable Due to Excessive Circuit Noise on Signal Line Interferring W/Automatic Switching Function.Time Relay Item Repaired
LIC-91-0089, Special Rept:On 910610,gas Stack Monitor Failed New Surveillance Test for post-installation Testing.Caused by Excessive Circuit Noise on Signal Line.Troubleshooting Efforts Underway to Isolate Source of Noise24 June 1991Special Rept:On 910610,gas Stack Monitor Failed New Surveillance Test for post-installation Testing.Caused by Excessive Circuit Noise on Signal Line.Troubleshooting Efforts Underway to Isolate Source of Noise
LIC-91-0011, Special Rept:On 910211,both Barrier Penetrations 19-E-39 Between Room 19 & Turbine Bldg & Concrete Block Wall at East End of Corridor 4 Breached to Support Long Term Maint on HX AC-1A.Appropriate Compensatory Measures in Place20 March 1991Special Rept:On 910211,both Barrier Penetrations 19-E-39 Between Room 19 & Turbine Bldg & Concrete Block Wall at East End of Corridor 4 Breached to Support Long Term Maint on HX AC-1A.Appropriate Compensatory Measures in PlaceFire Barrier
Continuous fire watch
Hourly Fire Watch
LIC-90-0876, Special Rept:On 901009,fire Door 1011-1 Declared Inoperable as Fire Barrier.Caused by Damage to Skin of Door During Corrective Maint on Lockset.Door Expected to Be Replaced by 90123115 November 1990Special Rept:On 901009,fire Door 1011-1 Declared Inoperable as Fire Barrier.Caused by Damage to Skin of Door During Corrective Maint on Lockset.Door Expected to Be Replaced by 901231Fire Barrier
Hourly Fire Watch
LIC-90-0608, Special Rept:On 900629,inoperability of Fire Protection Equipment Occurred Due to Excessive Security Alarms Being Received on Door.Door Propped Open & Required Fire Protection/Security Measures Established3 August 1990Special Rept:On 900629,inoperability of Fire Protection Equipment Occurred Due to Excessive Security Alarms Being Received on Door.Door Propped Open & Required Fire Protection/Security Measures EstablishedFire Barrier
Continuous fire watch
Hourly Fire Watch
LIC-90-0569, Followup RO Re Inoperability of Fire Door 1013-7.Since Replacement Work for Door Involves Removal of Part of Pyrocrete Wall That Surrounds Door Opening,Door Operability Delayed Until 900801.Compensatory Measures in Place29 June 1990Followup RO Re Inoperability of Fire Door 1013-7.Since Replacement Work for Door Involves Removal of Part of Pyrocrete Wall That Surrounds Door Opening,Door Operability Delayed Until 900801.Compensatory Measures in PlaceFire Barrier
ML20247L66519 September 1989Special Rept:Consisting of Restoration Info on Impairment of Fire Detection Zones,Fire Doors & Fire Barrier Penetrations. Compensatory Measures in Effect During Period of Inoperability.Fire Door 1013-6 Restored on 881123Fire Barrier
ML20246N05431 August 1989Special Rept:Inoperability of wide-range Noble Gas Stack Monitors RM-063L,RM-063M & RM-063H for post-accident Monitoring Discovered.Flow Controllers Repaired & Calibr Begun to Return Monitors to Svc by 891215
ML20246M12410 July 1989Special Rept:On 890602 & 0606,discovered Fire Barrier Penetration Seals 53-N-2 & 26-W-1 Inoperable.Caused by Procurement Delays Associated W/Acquisition of Seal Matl Certification & Technical Info.Followup Rept Will Be FiledFire Barrier
ML20245A11415 June 1989Special Rept:On 890509 & 0517,Tech Spec 2.19(7) Violated. Caused by Fire Door 1036-01 & Fire Barrier Penetration Seal 26-F-164 Being Inoperable for More than 7 Days.Required Compensatory Measures Established & Maintained for PeriodFire Barrier
ML20247K27423 May 1989Special Rept:On 890508,wide-range Noble Gas Stack Monitors RM-063L,RM-063M & RM-063H Removed from Svc for Calibr of Flow Control Circuit & Not Returned to Svc within 7 Days. Caused by Malfunctioning Dahl ControllerPost Accident Monitoring
ML20247F97919 May 1989Special Rept:On 890421,inoperability of Inadequate Core Cooling Instrumentation Parameters,Due to Software Upgrades, Occurred for More than 7 Days.Addition of Indication of PCV-1849A & B to SPDS PlannedPost Accident Monitoring
ML20245L3271 May 1989Special Rept:On 890317 & 30,fire Detection Zone 15 & Fire Barrier Seal 20-E-7 out-of-svc Greater than 14 & 7 Days, Respectively,Exceeding Tech Spec Limits.Required Compensatory Measures Established & MaintainedFire Barrier
ML20246L40817 March 1989Followup Special Rept:On 890227,detector RE-063H & Preamplifier RM-063H Found Defective.Replacement Detector Purchased & RM-063H Will Be Fully Operational by 890515
ML20235R23523 February 1989Special Rept:On 890209,main Steam Line Radiation Monitor RM-064 & Wide Range Noble Gas Stack Monitors RM-063L & RM-063H for post-accident Monitoring Inoperable.Cause Not Stated.Planned Method for Monitoring Parameter Verified
LIC-88-1006, Ro:On 881001-31,listed Fire Barriers & Detection Sys Rendered Inoperable.Fire Detection Zones 9 & 30 Rendered Inoperable on 881001 & 05,respectively.Restoration within Tech Spec Limit Could Not Be Accomplished14 November 1988Ro:On 881001-31,listed Fire Barriers & Detection Sys Rendered Inoperable.Fire Detection Zones 9 & 30 Rendered Inoperable on 881001 & 05,respectively.Restoration within Tech Spec Limit Could Not Be AccomplishedFire Barrier
Fire Watch
ML20206C8019 November 1988Special Rept:Consisting of Followup to 881010 Rept Re Inoperability of Radiation Monitor RM-064.Investigation Confirmed Defective Preamplifier at Detector.Util Working W/Vendor to Resolve Problem
ML20205Q53631 October 1988Followup Special Rept on Inoperability of Fire Doors.Maint & Replacements Associated w/851030 Special Rept Completed.Util Initiated Replacement Program for Firedoors.Compensatory Measures in Effect for Doors Being Replaced
ML20205E29919 October 1988Followup Ro:Maint Completed & Fire Barrier Separating Fire Areas 19 & 20 Restored to Operable Status on 880919Fire Barrier
ML20207L80210 October 1988Special Rept:On 880923,main Steam Line post-accident Radiation Monitor RM-064 Turned Off Due to Apparent Power Supply Failure.Caused by Inherent Characteristics of Electronic Ratemeter.Monitor Turned Back onPost Accident Monitoring
ML20245D8903 October 1988Special Rept:On 880826,fire-rated Penetration Seals Declared Inoperable.Fire Detector Operability Verified & Hourly Firewatch Patrol Initiated on One Side of Each Affected PenetrationFire Barrier
ML20155C2703 October 1988Special Rept on Untimely Submittal of 19 Lers.Training on Safety Responsibilities to Begin Immediately Following Development of Training PlanSafe Shutdown
Time of Discovery
Shutdown Margin
High Radiation Area
Grab sample
Fire Barrier
Missed surveillance
ML20154N48023 September 1988Special Rept:On 880822,fire Barrier Penetration Seals 26-N-24 & 69-F-186 Rendered Inoperable During Plant Mod. Seals Remained Inoperable in Excess of 7 Days.Firewatch Patrol InitiatedFire Barrier
ML20154N53323 September 1988Special Rept Re Fire Door Locksets & Door Mods.Several Fire Doors Replaced During Plant Mods.Hourly Firewatch Patrol Being Maintained in Areas Where Modified Fire Doors Inoperable in Excess of 7 DaysFire Barrier
ML20154G99415 September 1988Special Rept:On 880809 & 0815,fire Barrier Penetration Seals Inoperable for More than 7 Days Due to Unavailable Seal Matl.Fire Detector Operability Verified,Hourly Watch Initiated & Seals Restored to Operable StatusFire Barrier
ML20154H01714 September 1988Special Rept:On 880815,B Channel Reactor Vessel Level Instrumentation Inoperable Due to Junction Thermocouple Probe Failure.Replacement Sensors to Be Purchased