ML23207A076 | 14 July 2023 | EN 56557 - Update to Part 21 Report Re Potential Defect with Trane External Auto/Stop Emergency Stop Relay Card Pn: XI2650728-06 | |
ML22303A004 | 31 August 2022 | Final Report Notification Pursuant to 10 CFR Part 21.21, Regarding Supply of 6 NPS Sch. 40 Seamless Stainless-Steel Pipe; Manufacturer: Maxim Tubes Company Pvt. Ltd.; Heat No: N200309AW01, SR No: 7; 9 Pcs; 180 Feet Total Procured as Unquali | |
ML22259A173 | 26 August 2022 | EN 55960 - Curtiss Wright Part 21 Report Re Potential Defect in Configuration of the Quick Disconnect Connector Cable Assemblies Supplied to McGuire and Catawba Nuclear Power Stations | |
ML22222A009 | 1 July 2022 | EN 55974 - Flowserve, Part 21 Report Re Solenoid Coil Failure of Model 38878-8 Solenoid Valve at Catawba Nuclear Station for Use on FWIV Actuator | Commercial Grade Loctite |
ML19346H873 | 12 December 2019 | Westinghouse Electric Company - Notification of the Potential Existence of Defect Pursuant to 10 CFR Part 21 | |
ML19347A426 | 10 December 2019 | General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) | Post Accident Monitoring |
ML18302A228 | 19 October 2018 | Itt Enidine - USNRC 10CFR Part 21 Notification | |
ML18269A112 | 12 September 2018 | Engine Systems, Inc. Report No. 10CFR21-0122, Rev. 0 - 10CFR21 Reporting of Defects and Non-Compliance | |
ML17194A825 | 11 July 2017 | Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections | Anchor Darling |
ML17173A139 | 9 June 2017 | Engine Systems, Inc. - Transmittal of 10CFR21 Reporting of Defects and Non-Compliance - Report No. 10CFR21-0117, Rev. 0 | |
ML17165A407 | 9 June 2017 | Part 21 Report - Defective Motor Operated Potentiometer | |
ML16328A310 | 18 November 2016 | Notification of the Potential Existence of Defects Pursuant to 10 CFR Part 21 | Foreign Material Exclusion |
ML16294A264 | 18 October 2016 | Part 21 Report - Defective Current to Pressure Transducers | |
ML16209A050 | 13 July 2016 | Part 21 - Furmanite Nuclear Grade Leak Seal Material FSC-N-1B | |
ML16196A064 | 10 July 2016 | Part 21 Report - Materials Not Properly Dedicated | |
ML16127A595 | 4 May 2016 | Rotork Controls Inc. Part 21 Notification Concerning V12 (Pt No. N69-921) and K5 (N69-838 & N69-926) Safety Related Micro Switches | Coatings |
ML16258A456 | 5 November 2015 | Part-21 Report - Closed Switch Not Actuating When Valve Is Fully Closed | |
ML15303A006 | 26 October 2015 | Part 21 Report Regarding Closed Switch No. Actuating When Valve Is Fully Closed, Per Catawba Nuclear Station | |
ML15103A244 | 6 April 2015 | Part 21 Report - Deviation of Hk Circuit Breaker Close Latch Spring | Commercial Grade Dedication |
ML15049A458 | 6 February 2015 | Thermo Gamma-Metrics, LLC - Part 21 Report Regarding Shutdown Margin Monitor Environmental Qualification Noncompliance | Shutdown Margin |
ML14094A445 | 1 April 2014 | Notification of Part 21 Report on Defective Raw Material Used to Manufacture Valve Stems | |
ML14085A012 | 21 March 2014 | Notification of Part 21 - Sbm Selector Switches Contact Assembly Unplanned Manufacturing Change | |
ML13284A084 | 3 October 2013 | Deficiency Report from Baldor Electric Co., on Nuclear Nonconformance Event No. 49302 | |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML13102A303 | 10 April 2013 | Part 21 Involving a Potential Weld Defect | Hydrostatic |
ML13099A093 | 5 April 2013 | Part 21 Report of Limitorque Valves with Incorrect Motor Nameplates Installed | |
ML13079A320 | 18 March 2013 | Notification of Potential Part 21 Interim Report Re Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters | |
ML13064A012 | 25 February 2013 | Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve | Anchor Darling |
ML12352A123 | 13 December 2012 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12348A136 | 13 December 2012 | Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers | |
ML12356A302 | 27 November 2012 | Notification of Potential Part 21 Report Involving Performance of Npt Stamped Cavitrol III Plugs at Catawba Nuclear Station | |
ML12094A371 | 2 April 2012 | Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations | |
ML12066A118 | 2 March 2012 | Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations | |
ML12097A316 | 2 March 2012 | Part 21 Report - Rosemont Pressure Tranmitters Out of Tolerance Condition | |
ML12058A141 | 23 February 2012 | Part 21 Report - Rosemount Nuclear Instruments, Inc., Pressure Transmitter with Nonzero Based Calibrations | |
ML11298A190 | 18 October 2011 | 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0103, Rev. 0, Piston Assembly - Delamination of Tin Plating on Refurbished Piston Skirts | |
ML11292A010 | 17 October 2011 | Part 21 Notification - Emergency Diesel Generator Piston Delamination | |
ML11287A139 | 13 October 2011 | Stations - Amended 10CFR21 Notification - Identification of Defect Mackson, Inc. - Defective Tube Steel - NRC Event Number 46375 | Non-Destructive Examination Commercial Grade Liquid penetrant |
ML110550615 | 22 February 2011 | Duke Energy - Notification of Potential Part 21 Re Identification of Defect | Commercial Grade |
ML110280015 | 24 January 2011 | Notification of Potential Part 21 - Bus Disconnect Stab Assembly - 600V Essential Motor Control Centers | Unanalyzed Condition Fitness for Duty Commercial Grade Siren |
ML103060102 | 29 October 2010 | Notification of Potential Part 21 Transfer of Information Concerning Control Components Inc. (CCI) Drag Valves | Boric Acid |
ML102530446 | 8 September 2010 | Rotork Inc. Part 21 Notification Sintered Gear | Commercial Grade Power-Operated Valves |
ML100920093 | 25 March 2010 | 10 CFR21 Notification of a Potential Weld Defect | |
ML090761188 | 11 March 2009 | Part 21 Notification - Defective Hk and K-Line Circuit Breaker Tension Springs | |
ML090410485 | 6 February 2009 | Notification of Potential Part 21 Report (Draft) Re Defective ASME SA-193, Grade 6 Cap Screw Material | |
ML090350217 | 27 January 2009 | Notification of Potential Part 21 Report from Fisher Controls International - Water Quality Deficiency | |
ML090350211 | 16 January 2009 | Part 21 Report Re Identification of Defect Found in Basic Component. Initially Reported to NRC on 12/18/2008 | Commercial Grade |
ML083540469 | 18 December 2008 | Duke Energy Carolinas, Llc., Deficiency Report on Defective Digital Optical Isolators | Unanalyzed Condition Commercial Grade |
ML083190017 | 12 November 2008 | Notification of Potential Part 21 on All Dimensionally Verified Commercial Grade Items Processed Per Fisher Manufacture Procedure Fmp 2K28 | Commercial Grade |
ML082390106 | 25 August 2008 | Notification of Potential Part 21 on Failure of F and G Switches | Test box |