Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML22098A117 | 29 March 2022 | Engine Systems, Inc. Report No. 10CFR21-0134, Rev. 0 - 10CFR21 Reporting of Defects and Non-Compliance - (Emo Cylinder Head with Fireface Thickness Below Specification Cylinder Head P/N 40121485) | |
ML21096A114 | 6 April 2021 | Ametek Solidstate Controls - Updated Interim Notifcation | |
ML20296A276 | 6 October 2020 | Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21 - Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML20049A075 | 11 February 2020 | C&D Technologies, Inc. -10 CFR Part 21 Evaluation Regarding Container Failure in KCR-07 Batteries | |
ML20021A045 | 3 January 2020 | Lake Engineering Co. - Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 | |
ML19325C094 | 7 November 2019 | Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch ZJS1518 Final Report Per 10 CFR Part 21 | |
ML19317D093 | 25 October 2019 | Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing | |
ML19295D732 | 11 October 2019 | Engine Systems, Inc. Report No. 10CFR21-0125, Rev. 1 - Signal Converter Transmitter | Safe Shutdown Commercial Grade Dedication |
ML19263A666 | 9 September 2019 | Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 | |
ML19213A025 | 26 July 2019 | Ultra Electronics - Update to ML19155A084 10CFR21 Interim Report | |
ML19207A056 | 19 July 2019 | Engine Systems, Inc. - Part 21 Report 10CFR21-0125, Rev. 0, for a 10CFR21 Reportable Notification on a Signal Converter Transmitter | Safe Shutdown Commercial Grade Dedication |
ML19210D434 | 11 July 2019 | Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 | |
ML19190A043 | 28 June 2019 | Discusses Proprietary Information for Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 | |
ML19158A131 | 31 May 2019 | Paragon Energy Systems LLC -10 CFR Part 21 Report of Defect GS2 Terry Turbine Introl Positioners | |
ML19155A084 | 31 May 2019 | Ultra Electronics - Interim Notification Per 10CFR21 | |
ML19106A106 | 12 April 2019 | Ametek Solidstate Controls - Notification of Potential Defect - 10 CFR Part 21 | |
ML19080A059 | 8 March 2019 | Interim Report of Potential 10CFR Part 21, Eaton A200 Series Starters/Contactors | |
ML19008A043 | 4 January 2019 | Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11KLVS146 | |
ML19029A155 | 27 December 2018 | 10 CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0123, Rev. 1 | |
ML18353A428 | 30 November 2018 | Engine Systems, Inc., 10CFR21-0123, Rev. 0, for a 10CFR21 Reportable Condition on Emd Fuel and Soakback Pumps | |
ML18302A228 | 19 October 2018 | Itt Enidine - USNRC 10CFR Part 21 Notification | |
ML18159A039 | 6 June 2018 | National Technical Systems (Nts) - Potential Part 21 on Dedicated Items Not Available for Pmi Testing (NUPIC) | |
ML18075A355 | 6 March 2018 | 10 CFR Part 21 Notification of Defect on Crane Nuclear Figure Number 83 1/2 Spl 10x8x10 and 6x4x6 Bolted Bonnet Gate Valve | |
ML17340A392 | 28 November 2017 | 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0119, Rev. 0 | Safe Shutdown |
ML17223A200 | 9 August 2017 | 10 CFR Written Notification for Hex Head Cap Screws Nova Machine Products Part Numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30 | Non-Destructive Examination |
ML17114A069 | 19 April 2017 | Part 21 Report - Control Rod Drive Mechanisms Contaminated with Chlorides | Safe Shutdown Pressure boundary leak |
ML17104A288 | 13 April 2017 | Emerson Process Management, LLC - Fisher Information Notice, (FIN) 2017-02 | |
ML17114A071 | 13 April 2017 | 10 CFR Part 21 Notification of Deviation - Gkt Relay | |
ML17081A453 | 20 March 2017 | Part 21 - Plastic Jar Dedication Sampling | |
ML16020A477 | 23 December 2015 | MPR Associates, Inc., - Part 21 Report, MPR Emergency Diesel Engine Timing Module Failure, Per E.I. Hatch, Unit 2 | |
ML16004A030 | 23 December 2015 | MPR Associates, Inc. - Part 21 Report, MPR Emergency Diesel Engine Timing Module Failure, Per E.I. Hatch, Unit 2 | |
ML15223B266 | 7 August 2015 | Part 21 Report - Crane Nuclear Pressure Seal Valve with Retaining Rings | Nondestructive Examination |
ML15223B268 | 7 August 2015 | Part 21 - Damaged Surveillance Capsules | Fitness for Duty |
ML15217A309 | 1 August 2015 | Notification of Part 21 - Report Involving Limit Switches EA180 and EA170 Manufactured in a Specific Date Range | |
ML15201A287 | 8 July 2015 | Crane Nuclear, Inc. - Part 21 Interim Report - Notification of Pressure Seal Valve Yoke Material Compliance | Nondestructive Examination |
ML15134A017 | 1 May 2015 | Part 21 Report Regarding Potential Test Induced Defect in a 0867F Main Steam Safety Relief Valves | Flow Induced Vibration |
ML14204A707 | 23 July 2014 | Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV | |
ML14210A010 | 23 July 2014 | Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve | Safe Shutdown Shutdown Margin Scram Discharge Volume |
ML14125A270 | 2 May 2014 | Missing Jam Nuts on Size 4, Pressure Class 600 Normally Open, In-Line Check Valve Per Flowserve Drawing No. 07-45546-01 | Anchor Darling |
W3F1-2014-0026, Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation | 11 April 2014 | Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation | |
ML14105A018 | 11 April 2014 | Part 21 - Model 1154HP Transmitters with Integral 1159 Remote Diaphragm Seals May Exhibit Degraded Functional Reliability | |
ML14069A467 | 26 February 2014 | Part 21 Report Involving a Potential Manufacturing Defect in Replacement Masterpact Cradles | |
ML14042A200 | 21 January 2014 | Part 21 Report Regarding Non-Conformance of an Electrical Tubular Water Heater | |
ML13246A087 | 23 August 2013 | Nuclear Nonconformance Event Number 49302 - 10CFR21 Notification | |
IR 05000391/2013003 | 21 August 2013 | Construction Deficiency Report 50-391/2013-03 - Failure to Implement Plant Changes - Final Report | Commercial Grade Dedication |
ML13240A006 | 21 August 2013 | Construction Deficiency Report 50-391/2013-03 - Failure to Implement Plant Changes - Final Report | Commercial Grade Dedication |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML13094A177 | 18 March 2013 | Notice to the U.S. Nuclear Regulatory Commission of a Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters Manufactured by Aaf | |
ML13044A075 | 8 February 2013 | Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology | |
ML13010A518 | 9 January 2013 | Part 21 Interim Report on the Failure of an Emergency Diesel Generator Excitation System |