Flaw Control Division Anchor/Darling Valves BW/IP Valves FLOWSE RVE Edward Valves Valtek Control Products Worcester Valves May 2, 2014 US Nuclear Regulatory Commission Document Control Desk 11545 Rockville Pike Rockville, MD 20852-2746
Subject:
Missing Jam Nuts on Size 4, Pressure Class 600 Normally Open, In-Line Check Valve per Flowserve Drawing No. 07-45546-01
Attachment:
Flowserve Drawing No.07-45546-01 Ladies/Gentlemen:
This is to notify the US Nuclear Regulatory Commission that, in accordance with the provisions of 1 OCFR Part 21, on this date I was notified that Flowserve has identified a potential defect and are henceforth submitting our evaluation of the event.
Nature of the Defect: In March of 2014, PG&E Diablo Canyon visual inspection discovered the outer jam nut was missing from the valve stem and was found downstream. This jam nut locks the inner jam nut which retains the spring and spring retainer. There were signs of one stake on the stem threads. These check valves include a conical spring which maintains the disc open in its normnal position. Flow in the normal direction maintains the valve open and a minimum reverse flow is required to close the valve. The valve is used in saturated steam service and must close with a reverse flow of less than 7000 lbs/hr steam at 95 and 1085 psig. The PG&E supplied data sheet does not identify a specific safety related function. However, the valve operating parts are identified as safety related on the drawing.
The valve will not maintain an open position with limited reverse flow without the spring in place and the spring will not be available to assist holding the disc open and stable during forward flow.
A second, identical valve at the site was also inspected and no defects were found.
Background:
In February 2013, PG&E Diablo Canyon visual inspection discovered that both jam nuts, the spring retainer and the spring were missing from an identical valve. There were signs of one stake on the stem threads as required by the drawing however the staked thread had broken and the stake depth was minor. Flowserve evaluated the failure as required by 10 CFR 21 and the consensus of the evaluation committee was that based on history with this product and our experience with the staking of threads in general the failure was an isolated incident.
Flowserve U S Inc Raleigh Operations Toll Free:
1-800-225-6989 Flow Control Division PO Box 1961 Phone:
1-919-832-0525 1900 South Saunders Street Facsimile:
1-919-831-3369 Raleigh, NC 27603 www.flowserve.com
A recommendation was provided to PG&E to torque the jam nuts prior to staking and to stake the stem thread in two locations when reassembling the valve. In addition, Flowserve factory personnel were trained on enhanced staking techniques.
Evaluation: Flowserve has completed an evaluation of the most recent failure and concluded that the root cause of the outer jam nut loosening and unscrewing from the stem, most likely is from inadequate nut tightening and staking. The original assembly drawings for the valves did not specify the required torque value and specified only one stake requirement. Based on the fact that this is the second failure of this type Flowserve no longer considers it to be an isolated incident and that it is reportable under the requirements of 10 CFR 21.
Extent of Condition: Flowserve records indicate that in addition to the PG&E Diablo Canyon site, a quantity of 5 similar valves per drawing W9925475 (Anchor Darling SO E023T-1) were supplied to the TVA Sequoyah plant from Flowserve's Williamsport, PA plant in 2000.
Corrective actions taken:
As noted above after the initial failure, on March 7, 2013, PG&E Diablo Canyon was notified by letter to torque the jam nuts to 44 ftlbs and to stake the threads in two places when reassembling the valve.
For future reference Assembly Drawings 07-45546-01 and W9925475 which cover the designs of the Diablo Canyon valves and a similar design used for the TVA Sequoyah Plant were revised to add jam nut torque and more detailed thread staking notes.
In additional to the instructions given on the assembly drawing, in the future Flowserve's internal assembly instructions will include more detail regarding the torqueing and staking operations.
Based on the second valve failure, Flowserve recommends that PG&E Diablo Canyon and TVA Sequoyah inspect all in service valves for proper torque and provide dual thread staking per the revised drawings.
Respectfully submitted,
/Jnes T. McGeehin eneral.Manager Flowserve Corporation Flow Control Division 1900 S. Saunders St.
Raleigh, NC 27603 2
T Lo-9tv9t-Lo I
No rY OESCRINION 48A8T51.i.
MAI L 0011 I
BODY SA216-WCO BA 004-I DISC/S0T8 S' 479-318L..
A O13 1
SEAT R1NN S351.--coM 4A.46 06a I
BUSH1140 (00iY)
A564-630-900 "8
0004 BUSPRING (SEAT BING)
A564-630-900
-8 244 2
PRN NUTS A4194-2 0,7 245 1NAMEPLATE AS]4 X4 348 I
IEWIMTIO)C5I4 PLATE 4151 304 431 1001064141 88380 AT 95 MI'D 1065 M, O.,.,LmoNI"M-A-ETEFO RIL *:
A...ALIOAF CATOMES5 A. P905S01 RE BOUNDARY.
A WET'[ RFIAT1).
L-VALVE DESIGN SPECIFICATION; 8179 REV, 2N P1AC;OC GAS & ELECTRIC COUPA5,NY MIAELO 541704 POWER3 PLAN4T SE0CTON A-A VALVE IS ASME SECTION II. CLASS 3 1959 EDITION, NO ADDENDA:
WIlH N-STAIAP VALVE DESION PRESSURE IS 1085PSiG 0 600'F COLD WORKING. PRESSURE IS 1450 PSIG FLOWSIVE *
- ALP, 0
0 RAILEIG3H.
NG I H 1 I1 7 I,/ 17/0 7 8
e1l/ ii/ L,,s sl it )t
,4 ho
'N-LINE CHECK VALVE CARBON STEEL, FLANGED ENDS NORMALLY OPEN SIZE:
4 CLASS: 600 C1607645546-01 P4ý.
I A 1 3930. 1 1
1 7/17/07 X 9810/20/071 119SC 9/2t/07 I 820 4/24/01-I
.r
% I
]
I _._..
() I -....
I I 7/17/07 1 WK 7/17/0 OMAN 7/27/0710WM 8/01/07 I
1 i
I s 1
o*s 0144 1 woM 5470 086818 01050m 4015 T 7
wammS
=
L_