MONTHYEARML24302A2772024-10-28028 October 2024 57243-EN 57243_5 - Rssc Dba Marmon - Update 20241030 ML24239A3972024-08-23023 August 2024 Rssc Wire & Cable LLC Dba Marmon - Part 21 Final Notification - 57243-EN 57243 ML20279A5772020-11-23023 November 2020 U.S. Nuclear Regulatory Commission'S Analysis of Public Service Enterprise Group Nuclear, LLC Decommissioning Plans Update for Salem Generating Station, Hope Creek Generating Station and Peach Bottom Independent Sfsis ML20296A2762020-10-0606 October 2020 Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21 - Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML19325C0942019-11-0707 November 2019 Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch ZJS1518 Final Report Per 10 CFR Part 21 ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19263A6662019-09-0909 September 2019 Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19210D4342019-07-11011 July 2019 Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 ML19190A0432019-06-28028 June 2019 Discusses Proprietary Information for Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 ML19080A0592019-03-0808 March 2019 Interim Report of Potential 10CFR Part 21, Eaton A200 Series Starters/Contactors ML19008A0432019-01-0404 January 2019 Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11KLVS146 ML19029A1552018-12-27027 December 2018 10 CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0123, Rev. 1 ML17355A1392017-12-0505 December 2017 Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 14ELVS145 Final Report Per 10 CFR Part 21 ML17223A2002017-08-0909 August 2017 10 CFR Written Notification for Hex Head Cap Screws Nova Machine Products Part Numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30 ML17206A0392017-07-13013 July 2017 Part 21 - Hex Cap Screws Produced with Pre-existing Cracks ML17114A0712017-04-13013 April 2017 10 CFR Part 21 Notification of Deviation - Gkt Relay ML17104A2882017-04-13013 April 2017 Emerson Process Management, LLC - Fisher Information Notice, (FIN) 2017-02 ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML14259A3892014-09-0808 September 2014 Part 21 - Failure to Meet Specified Irradiation During Testing of Coated Test Panels ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14105A0182014-04-11011 April 2014 Part 21 - Model 1154HP Transmitters with Integral 1159 Remote Diaphragm Seals May Exhibit Degraded Functional Reliability ML14079A0272014-03-13013 March 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13094A1772013-03-18018 March 2013 Notice to the U.S. Nuclear Regulatory Commission of a Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters Manufactured by Aaf ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML13002A0302012-12-21021 December 2012 Part 21 Notification - Defect Discoveredd in COM-5 and SSC-T Protective Relays Distributed by Abb, Inc ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology ML12283A2462012-09-28028 September 2012 Part 21 - Fairbanks Morse Opposed Piston EDG Oil Pump Leak ML12319A0122012-09-27027 September 2012 Error in Main Steam Line High Flow Calculational Methodology ML12258A3992012-09-10010 September 2012 Potential Part 21 Issue Related to Tyco Timing Relay ML12158A4472012-06-0606 June 2012 Part 21 60-Day Interim Report Notification - Closufailure of CRD Collet Retainer Tube/Outer Tube Weld ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12097A3162012-03-0202 March 2012 Part 21 Report - Rosemont Pressure Tranmitters Out of Tolerance Condition ML12066A1182012-03-0202 March 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML1127000672011-09-26026 September 2011 GE-Hitachi Part 21 Reportable Condition Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1025202192010-09-0303 September 2010 Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1018907392010-07-0101 July 2010 Part 21 Report Concerning Failure of Turbine Overspeed Reset Control Valve Diaphragm ML0907611882009-03-11011 March 2009 Part 21 Notification - Defective Hk and K-Line Circuit Breaker Tension Springs ML0810701722008-04-0909 April 2008 Notification of Potential Part 21 Regarding Torus Immersion/Vapor Phase Coatings ML0520003332005-07-14014 July 2005 Part 21 Communication: Circuit Breaker Replacement Primary Bushings Not Tested to ANSI Standards ML0328704222003-10-0909 October 2003 Potential Safety Condition for Eaton Cutler-Hammer Type W Vintage Unit Plug-In Stabs ML0232901622002-11-18018 November 2002 Final Report, Stability Option III: Possible Successive Confirmation Count Resets - Not Reportable 2024-08-23
[Table view] Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML24255A8642024-09-0606 September 2024 Rscc Wire & Cable LLC Dba Marmon Industrial Energy & Infrastructure - Part 21 Retraction of Final Notification ML22301A1742022-10-28028 October 2022 Global Nuclear Fuel Americas, LLC (GNF) - Part 21 60-Day Interim Report Notification: GNF3 Raised Water Rod (SC-22-04 Rt) ML21322A0512021-10-27027 October 2021 Paragon Energy Solutions, LLC, P21-09282021, Rev. 0, Final Notification of a Deviation with Inverter Assembly (Model NLI-072034-CSI-K-5-A) ML21225A0812021-08-0404 August 2021 Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML21014A2342020-12-0707 December 2020 Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML20108F5302020-03-20020 March 2020 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0129, Rev. 0, Test Stand Deficiency - EMD Fuel Injectors P/N H40084720 ML20049A0742020-01-31031 January 2020 Fairbanks Morse Part 21 Re Fm Notification Report Serial Number 20-01 Fairbanks Morse ML20024E2552020-01-0909 January 2020 Engine Systems, Inc., Submittal of Selenium Surge Suppressor, Emo P/N 8403049 ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19253A0532019-08-29029 August 2019 Azz Nuclear - Report of Potential 1O CFR Part 21, Eaton Size 1 and 2 A200 Series Starters/Contactors ML19199A0342019-07-0505 July 2019 Lake Engineering Co., Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19190A0442019-06-0707 June 2019 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 ML19168A0122019-05-31031 May 2019 Paragon Energy Solution LLC-10 CFR Part 21 Report of Defect GS2 Terry Turbine Introl Positioners ML19168A0102019-05-31031 May 2019 Curtis-Wright Nuclear Division- Notification Report for Potential Part 21 Update ML19120A1062019-04-17017 April 2019 Interim Report of Potential 10 CFR Part 21, Eaton Size 1 and 2 A200 Series Starters/Contactors ML19080A0592019-03-0808 March 2019 Interim Report of Potential 10CFR Part 21, Eaton A200 Series Starters/Contactors ML19077A0962019-03-0505 March 2019 Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19071A1122019-03-0101 March 2019 Lake Engineering Co., Corrected Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 11KLVS146 Final Report, Per 10 CFR Part 21 ML18295A1992018-09-24024 September 2018 Lake Engineering - Second Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11KLVS146 ML17313A4712017-11-0303 November 2017 Part 21 - Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 14ELVS145 Interim Report ML17243A1362017-08-28028 August 2017 Fisher Information Notice, (FIN) 2017-04 - Erroneous Rotary Seating Torque Calculation in Flowscanner Software ML17223A2002017-08-0909 August 2017 10 CFR Written Notification for Hex Head Cap Screws Nova Machine Products Part Numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30 ML17212A6282017-07-24024 July 2017 Lake Engineering Co. - Potentially Degraded Snubber SF1154 Hydraulic Fluid Second - Interim Notification Per 10 CFR Part 21 ML17206A0392017-07-13013 July 2017 Part 21 - Hex Cap Screws Produced with Pre-existing Cracks ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17179A3782017-06-0707 June 2017 TE Connectivity - Part 21 Transfer of Information TE-023 ML17104A2882017-04-13013 April 2017 Emerson Process Management, LLC - Fisher Information Notice, (FIN) 2017-02 ML17114A0702017-04-13013 April 2017 Part 21 Notification - Identified Fisher 546S Electro-Pneumatic Transducers Standard Mounting Brackets Failed Seismic Testing Standards ML17114A0712017-04-13013 April 2017 10 CFR Part 21 Notification of Deviation - Gkt Relay ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML16321A4512016-10-21021 October 2016 Part 21 Reporting of Defects and Noncompliance ML16251A0982016-09-0202 September 2016 Part 21 - Potential Failure of Battery System Connections ML16243A4722016-08-25025 August 2016 Part 21 Reporting of Defects and Noncompliance ML16188A3742016-06-30030 June 2016 Part 21 - Inadequate Swaging and Adherence of Silicone O-Ring and Silicone PAD Soft Seat Main Disc and Pilot Disc Assemblies ML16154A2062016-05-18018 May 2016 Part 21 Report - Defect in a Signal Converter Transformer ML16139A8342016-05-10010 May 2016 Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 ML16125A3602016-04-26026 April 2016 Part 21 - Hydraulic Snubber Seal Material Deviation Interim Report ML16076A2622016-03-14014 March 2016 Anvil Engineered Pipe Supports - Part 21 Regarding Hydraulic Snubber Seal Material Deviation Interim Report, Per Peach Bottom ML16039A2692016-02-0303 February 2016 Nutherm International, Inc. - Potential Issue Regarding Incorrect Industrial Irradiation Dose, Per Cooper, Oconee, Fitzpatrick, Point Beach, Brunswick, and Susquehanna ML15103A2442015-04-0606 April 2015 Part 21 Report - Deviation of Hk Circuit Breaker Close Latch Spring ML15049A4562015-02-11011 February 2015 Weir Valves and Controls, USA - Part 21 Report Regarding Tricentric Triple Offset Valve ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification ML15014A0612015-01-0808 January 2015 Notification of Potential Part 21 Re Failure of Sbm Type Switches ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities ML14259A3892014-09-0808 September 2014 Part 21 - Failure to Meet Specified Irradiation During Testing of Coated Test Panels ML14204A7082014-07-23023 July 2014 Enclosure 2, Description of Closure Evaluation, Non-Proprietary Information - Class I (Public) ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve 2024-09-06
[Table view] |
Text
04/11/2014 U.S. Nuclear Regulatory Commission OperationsCenter Event Report Page I Part 21 (PAR) Event# 50020 Rep Org: ROSEMOUNT NUCLEAR INSTUMENTS, INC Notification Date I Time: 04110/2014 11:50 (EDT)
Supplier: ROSEMOUNT NUCLEAR INSTUMENTS, INC Event Date I Time: 04/10/2014 (CDT)
Last Modification: 04/10/2014 Region: 3 Docket #:
City: CHANHASSEN Agreement State: Yes County: License #:
State: MN NRC Notified by: DUYEN PHAM Notifications: PATTY PELKE R3DO HQ Ops Officer: CHARLES TEAL PART 21 GROUP EMAIL Emergency Class: NON EMERGENCY 10 CFR Section:
21.21(d)(3)(i) DEFECTS AND NONCOMPLIANCE PART 21 - MODEL 1154HP TRANSMITTERS WITH INTEGRAL 1159 REMOTE DIAPHRAGM SEALS MAY EXHIBIT DEGRADED FUNCTIONAL RELIABILITY "Pursuant to 10 CFR Part 21, section 21.21(b), Rosemount Nuclear Instruments, Inc. (RNII) is writing to inform you that certain Model 1154HP transmitters with integral 1159 Remote Diaphragm Seals may exhibit degraded functional reliability.
"The standard maximum working pressure for Model 1154 transmitters with integral 1159 Remote Diaphragm Seals is 2000 psi.
"Per the unique requirements of Point Beach Nuclear Generating Station, Model 11 54HP5RAGN0080 pressure transmitters with integral 11 59A50AS0 111 Remote Diaphragm Seals were manufactured to operate at a non-standard maximum working pressure of 2750 psi.
"Once installed in the field, two transmitters exhibited unexpected drift in the output signal when operated at line pressures of approximately 2235 psi.
"To date there are no known additional reported functional reliability issues with other Model 11 5x Series transmitters with integral 1159 Remote Diaphragm Seals in a similar configuration.
"RNII does not have complete information relating to specific plant applications and therefore cannot determine the potential effects of the condition on plant operation.
"This notification affects seven Model 1154HP transmitters with integral 1159 Remote Diaphragm Seals shipped to Point Beach Nuclear Generating Station since March 2013."
04/11/2014 U.S. Nuclear Regulatory Commission OperationsCenter Event Report Page 2 Name and address of the individual providing the information:
Mr. Marc D. Bumgarner Vice President & General Manager Rosemount Nuclear Instruments, Inc.
8200 Market Boulevard Chanhassen, MN 55317
'Apr/10/2014 10:50:16 AM EPM OUT RMT NUCLEAR 952-949-5201 1/4 EMERSON. ROSEMOUNT" Process Management Nuclear 8200 Market Boulevard Chanhasaen, MN 55317 USA Tel 1 (952) 949-5210 Facsimile Fax 1 (952) 949-5201
/NO. of Pages:4 Including cover page To: NRC Operations Center Fax Number: (301) 816-5151 Date: Thursday, April 10, 2014 Duyen Pham, Quality Phone: (952) 949-5383 From: Manager E-Mail: Duyen.Phamt&Emerson.com
Subject:
Notification under 10 CFR Part 21 on certain Rosemount Model 1154HP transmitters with Integral 1159 Remote Diaphragm Seals shipped to Point Beach Nuclear Generating Station Rosemount Nuclear Instruments, Inc. is submitting the attached notification as required by 10 CFR Part 21. Please contact me Ifyou have any questions, Sincerely, Duyen Pham Quality Manager Rosemount Nuclear Instruments, Inc.
www.RossrnountNuclear.com RNIl.lnfod1EmepsonProceus.com
Apr/10/2014 10:50:16 AM EPM OUT RMT NUCLEAR 952-949-5201 2/4 Rosemount Nuclear Instruments, Inc.
8200 Market Boulevard ROSEMOUNTI Chanhassen, MN 85317 USA Nuclear Tl (952) 94M21 0 Fax 1 (952) 94M-201 www.RosemountN uclear.com 10 April 2014 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attn: Document Control Desk Re: Notification under 10 CFR Part 21 on certain Rosemount Model 1154HP transmitters with Integral 1159 Remote Diaphragm Seals shipped to Point Beach Nuclear Generating Station Pursuant to 10 CFR Part 21, section 21.21(b), Rosemount Nuclear Instruments, Inc. (RNII) is writing to inform you that certain Model 11 54HP transmitters with integral 1159 Remote Diaphragm Seals may exhibit degraded functional reliability.
- The standard maximum working pressure for Model 1154 transmitters with Integral 1159 Remote Diaphragm Seals is 2000 psi.
- Per the unique requirements of Point Beach Nuclear Generating Station, Model I I54HPSRAGN0080 pressure transmitters with integral 11 59A5ASO0111 Remote Diaphragm Seals were manufactured to operate at a non-standard maximum working pressure of 2750 psi.
- Once Installed in the field, two transmitters exhibited unexpected drift Inthe output signal when operated at line pressures of approximately 2235 psi.
- To date there are no known additional reported functional reliability issues with other Model 11 5x Series transmitters with integral 1159 Remote Diaphragm Seals in a similar configuration.
RNII does not have complete information relating to specific plant applications and therefore cannot determine the potential effects of the condition on plant operation.
This notification affects seven Model 1154HP transmitters with integral 1159 Remote Diaphragm Seals shipped to Point Beach Nuclear Generating Station since March 2013.
1.0 Name and address of the individual providing the Information:
Mr. Marc D. Bumgarner Vice President &General Manager Rosemount Nuclear Instruments, Inc.
8200 Market Boulevard Chanhassen, MN 55317 2.0 Identification of Items supplied:
Seven 1154HP transmitters with integral 1159 Remote Diaphragm Seals shipped from; RNII to Point Beach Nuclear Generating Station since March 2013.
Page 1 of 2
'Apr/10/2014 10:50:16 AM EPM OUT RMT NUCLEAR 952-949-5201 3/4 3.0 Identification of firm supplying the Item:
Rosemount Nuclear Instruments, Inc.
8200 Market Boulevard Chanhassen, MN 55317 4.0 Nature of the failure and potential safety hazard:
Technical Overview:
Failure analysis efforts have demonstrated the output drift is due to a slow loss of fill fluid in one of the 1159 Remote Diaphragm Seal systems. The loss of fill fluid is due to a leak in the system, however failure analysis efforts to date have not determined the leak path.
Testing suggests the leak may be related to non-standard processing associated 1159 applications requiring maximum working pressures in excess of 2000 psi.
Potential Safety Hazard:
A leak in 1159 capillary fill fluid can cause the output to slowly drift over time. Excessive loss of fill fluid, over time, may result in a loss of transmitter functionality.
On April 4, 2014, RNI1 concluded that a substantial safety hazard may exist.
5.0 The corrective action which is taken, the name of the Individual or organization responsible for that action, and the length of time taken to complete that action:
Existing and new orders for Model 1I54HP transmitters with Integral 1159 Remote Diaphragm Seals with a maximum working pressure above 2000 psi will undergo extended production drift testing to verify performance prior to shipment.
Mr. Marc Bumgarner, VP & GM of Rosemount Nuclear Instruments, Inc. is responsible for any further action related to this issue.
6.0 Any advice related to the potential failure of the item:
RNII recommends implementing appropriate drift monitoring of the seven affected Model 1154HP transmitters with integral 1159 Remote Diaphragm Seals.
RNII is committed to the nuclear Industry and remains dedicated to the supply of high quality products to our customers. Ifyou have any questions, or require additional information related to this Issue, please contact: Mike Dougherty (208) 865-1112.
Sincerely, Marc DBugrne Vice President & General Manager Rosemount Nuclear Instruments, Inc.
Enc.: Appendix A - List of Affected Transmitters by Serial Number
- -O" Nuclear Page 2 of 2
Apr/10/2014 10:50,16 AM EPM OUT RMT NUCLEAR 952-949-5201 4/4 Appendix A: List of Affected Transmitters by Serial Number 10 CFR Part 21 Notification - 10 APRIL 2014 NEXTERA ENERGY, POINT BEACH LLC Sales Order Purchase Order Model Number Serial Number Ship Date Number 3492435 2300727 REV 003 1154HPSRGN0080 w/1159ASOAS0111 548595 Mar-13 REL 00001 3492435 2300727 REV 003 1154HPSRGN0080 w/ 1159ASOAS0111 548596 Mar-13 REL 00001 3492435 2300727 REV 003 1154HPSRGNOOBO w/II SA50AS01II 548597 Mar-13 REL 00001 3492435 2300727 REV 003 1154HP5RGN0080 w/1159A50AS0111 548615 Mar-13 REL 00001 3737832 02300727 REV 001 1154HPbRGN0080 w/1159A50AS0111 551728 Jan-14 REL 00005 3737829 02300727 REV 001 1154HPSRGN0OBO w/1159A50AS0111 551742 Feb-14 REL 00004 I t 1 3737829 02300727 REV 001 1154HP*SRGN'080 w/1159A50A80111 551743 Feb-14 REL 00004 Page I of I